MAURY USCG vessel records Sign in
← All vessels

ACADIAN

ACADIAN is a 1970 passenger vessel (inspected). The Coast Guard has recorded 62 inspections since 1985, most recently in May 2026, along with 77 deficiencies and 1 casualty investigation in 2023.

Records from 1985 to 2026. Most recent: inspection, 7 May 2026.

Built
1970
Last inspected
7 May 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDA8830
Flag
UNITED STATES
366858490
Maury page id
psix-46545

Inspections, by type

…with no type recorded7
Years with a record 37 calendar years (1985–2026)
The 62 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)60.8 ft × 20.0 ft × 7.6 ft
Registered tonnagegross 69 / net 47
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBLOUNT MARINE CORP · WARREN, RI, UNITED STATES · built 1970
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portBAR HARBOR, ME
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 28 April 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it69 - Regulatory (Subpart C or D), Gross Ton
47 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDA8830MMSI 366858490 · active · compulsorily equipped · granted 29 April 2022, expires 19 June 2032
WCZ9308MMSI not assigned · expired · voluntarily equipped · granted 10 July 2000, cancelled 11 September 2010
WUX8247MMSI not assigned · expired · compulsorily equipped · granted 12 August 1998, cancelled 1 November 2008
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

LULU Passenger (Inspected) · MISLE 916478 · 30 July 2023 · activity 7814150

Inspection history · 62

7 May 2026 Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 8353528
7 May 2025 COI Inspection · DAPI Audit
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 8104132
12 March 2025 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 8092450
23 May 2024 Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7869188
1 August 2023 Examination of Repairs
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7759198
30 July 2023 Type not recorded
No type recorded · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7814150
10 May 2023 Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7664750
31 March 2023 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7664755
11 April 2022 Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7428493
6 December 2021 Examination of Repairs
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7363416
13 July 2021 Type not recorded
No type recorded · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7269369
29 March 2021 Annual Inspection · Hull Examination · DAPI Audit
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7164507
28 May 2020 COI Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6962975
15 May 2020 Administrative Inspection
Administrative · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6953973
19 July 2019 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6766502
5 November 2018 Hull Examination · Examination of Repairs
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6574893
15 May 2018 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6412041
27 February 2018 Hull Examination
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6362415
23 June 2017 Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6184215
1 June 2016 Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 5916770
21 March 2016 Hull Examination
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 5813555
21 May 2014 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 4829453
21 June 2012 Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 4352295
18 June 2008 Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 3242325
8 April 2008 Drydock Exam
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 3514308
19 June 2007 Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 2966394
23 May 2006 Re-Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 2656727
6 April 2006 Hull Examination
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 2617116
3 May 2005 COI Inspection
Physical examination · MSFO BUCKSPORT · USCG Northeast District (CGD-NE) · Activity 2348086
2 July 2004 Re-Inspection
Physical examination · MSFO BUCKSPORT · USCG Northeast District (CGD-NE) · Activity 2118414
24 March 2004 Hull Examination
Physical examination · MSFO BUCKSPORT · USCG Northeast District (CGD-NE) · Activity 2034780
19 June 2003 Re-Inspection
Physical examination · MSFO BUCKSPORT · USCG Northeast District (CGD-NE) · Activity 1821226
23 April 2002 Re-Inspection · Hull Examination
Physical examination · MSFO BUCKSPORT · USCG Northeast District (CGD-NE) · Activity 1628613
4 June 2001 Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1067558
24 May 2001 Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1401500
8 May 2000 COI Inspection · Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1415355
13 May 1999 Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1129996
15 May 1998 Hull Examination · Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1398960
9 May 1997 COI Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1459326
10 May 1996 Hull Examination · Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1441099
4 December 1995 Administrative
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 882464
24 April 1995 Deficiency Check · Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1377398
19 May 1994 Hull Examination · COI Inspection · MARPOL Annex V Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 860292
19 January 1994 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 851587
8 June 1993 Re-Inspection · MARPOL Annex V Examination · Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 846780
30 April 1992 Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1264047
22 May 1991 COI Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 926932
11 April 1991 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 935499
3 July 1990 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 928259
2 May 1990 Re-Inspection · Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1241172
28 August 1989 Administrative
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1342751
6 June 1989 Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1201590
7 June 1988 COI Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1350570
9 May 1988 Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1347939
23 June 1987 Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1013332
22 June 1987 Administrative
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1312764
3 November 1986 Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1321195
4 September 1986 Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1318811
25 June 1986 Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 995240
28 May 1986 Credit Drydock
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 996152
25 June 1985 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1291538
15 May 1985 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1289935

Deficiency record · 77

07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 7 May 2025 Resolved
Complete annual fire safety inspection of gear.
Action required: 10 - Deficiency Rectified
Due 21 May 2025
Resolved 21 May 2025
Resolution: Fire servicing company completed annual service.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 16 May 2022 Resolved
Found 1/4 " hole in crash bulkhead, repair.
Action required: 705 - Other - as specified
Due 20 May 2022
Resolved 20 May 2022
Resolution: Hole sealed with temp material.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 16 May 2022 Resolved
Repair replace stern light, prove proper operation.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 May 2022
Resolved 20 May 2022
Resolution: New light installed, test sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 May 2022 Resolved
Found 01 life vest not serviceable, replace in kind.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 May 2022
Resolved 20 May 2022
Resolution: New adult life jacket, properly labeled and placed into service.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 May 2022 Resolved
Complete exhaust lagging installation to prevent / protect from hot surfaces.
Action required: 705 - Other - as specified
Due 20 May 2022
Resolved 20 May 2022
Resolution: Completed installation of HTE protective covering of exhaust.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 May 2021 Resolved
Make permanent repairs to starboard exhaust piping in lazaret.
Action required: 705 - Other - as specified
Due 10 June 2021
Resolved 22 February 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 June 2020 Resolved
Investigate and repair exhaust leak in lazaret.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 July 2020
Resolved 13 July 2020
Resolution: Issue was investigated with no indication of leak.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 17 June 2020 Resolved
Install double hose clamps on hose sections of bilge system.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 July 2020
Resolved 13 July 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 17 June 2020 Resolved
Provide double hose clamps on generator exhaust.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 July 2020
Resolved 13 July 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 17 June 2020 Resolved
Provide proper support of generator exhaust hose.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 July 2020
Resolved 13 July 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 June 2020 Resolved
Provide plugs in petcocks of fuel filters.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 July 2020
Resolved 13 July 2020
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 17 June 2020 Resolved
Provide new clamps on MOB recovery platform.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 July 2020
Resolved 13 July 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 June 2020 Resolved
Install guard on port main engine.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 July 2020
Resolved 15 June 2021
Resolution: Guard installed.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 15 May 2020 Resolved
The vsl's COI expired on 05 MAY 20, notified O/O. The vsl is restricted to not > 6 pax for hire until a sat COI exam is completed.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 June 2020
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 19 July 2019 Resolved
Fire hose nozzle became clogged with debris when in operation reducing the effective stream of the fire hose. Prove effective stream of fire hose.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 19 July 2019
Resolution: Nozzle removed, line flushed, and nozzle replaced.
Communications › Radio Communications › VHF Radiotelephone
Issued 15 May 2018 Resolved
Vessel operates beyond the base line and is required to be fitted with a DSC radio and MMIS number. Number is not inputted into radio. Input FCC assigned MMIS number.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 May 2018
Resolved 25 May 2018
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 15 May 2018 Resolved
Float-light battery is expired. Replace with non-expired battery.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 May 2018
Resolved 25 May 2018
Fire Fighting › Miscellaneous Items › A Class Division Penetrations
Issued 15 May 2018 Resolved
Provide provisions to close all engine room vents (intake and exhaust) in the event of a fire.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 June 2018
Resolved 21 June 2018
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 22 May 2014 Resolved
DAPI list of covered employees not available.
Due 5 June 2014
Resolved 27 May 2014
Resolution: Received current list of DAPI covered employees.
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 22 May 2014 Resolved
Provide method for closing off engine ventilation ducts.
Action required: 705 - Other - as specified
Due 5 June 2014
Resolved 21 July 2014
Resolution: Attended vessel and witnessed new magnetic covers provided for closing engine room ventilation.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 22 May 2014 Resolved
Lower bilge high level alarm in shaft alley mounted too high above the bilge and needs to be lowered.
Due 29 May 2014
Resolved 22 May 2014
Resolution: Lower bilge high level alarm in shaft alley re-mounted closer to the bottom of bilge. Corrected on the spot.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 19 June 2007 Resolved
Provide machinery guard on generator.
Action required: 705 - Other - as specified
Due 19 July 2007
Resolved 28 June 2007
Resolution: Received notification from O/O that new guard was purchased and installed.
Engineering › Fuel Oil Service System › Filter
Issued 19 June 2007 Resolved
Provide bowls on fuel filters.
Action required: 705 - Other - as specified
Due 19 July 2007
Resolved 28 June 2007
Resolution: Reveived notification from O/O that new bowls with plugs have been installed.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 23 May 2006 Resolved
PROVIDE SERVICING REPORT FOR PORTABLE FIRE EXTINGUISHERS
Action required: 705 - Other - as specified
Due 23 June 2006
Resolved 31 May 2006
Resolution: FIRE EXTINGUISHERS SERVICED
Engineering › Shafting/Propeller Arrangements
Issued 24 March 2004 Resolved
Provide closure handles for salt water feed valves for cutlass bearings both port and starboard side. LEGACY COMPONENT DESC: Stern Tube Lubrication/Sealing
Condition: Unknown
Action required: 705 - Other - as specified
Due 31 March 2004
Resolved 25 March 2004
Electrical › Electrical Distribution System (service) › Wiring
Issued 24 March 2004 Resolved
Remove dead-end wire in way of light fixture in #4 void.
Condition: Unknown
Action required: 705 - Other - as specified
Due 31 March 2004
Resolved 25 March 2004
Construction/Loadline › Hull › Side Shell
Issued 24 March 2004 Resolved
Remove and cap thru hull penetration in way of port side of #4 void.
Action required: 705 - Other - as specified
Due 31 March 2004
Resolved 25 March 2004
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 10 June 2002 Resolved
Properly label PFD storage
Due 10 July 2002
Resolved 18 June 2002
Resolution: Corrected
Accommodation/Occupational Safety › Occupational Safety
Issued 10 June 2002 Resolved
Properly label emergency escape
Condition: Unknown
Due 10 July 2002
Resolved 18 June 2002
Resolution: corrected
Lifesaving
Issued 24 May 2001 Resolved
PROVIDE RED CROSS FIRST AID/CPR CARDS FOR 50% OF CREW.
Condition: Unknown
Due 24 May 2001
Resolved 24 May 2001
Construction/Loadline
Issued 24 May 2001 Resolved
PROVIDE LABELS FOR BILGE SYSTEM VALVES.
Condition: Unknown
Due 24 May 2001
Resolved 24 May 2001
Lifesaving
Issued 24 May 2001 Resolved
REPLACE RETRO-REFLECTIVE TAPE ON (20) ADULT LIFEJACKETS.
Condition: Unknown
Due 24 May 2001
Resolved 24 May 2001
Accommodation/Occupational Safety
Issued 8 May 2000 Resolved
RENEW AS ORIGINAL THE LADDER IN THE FOREPEAK VOID SPACE.
Condition: Unknown
Due 9 May 2000
Resolved 8 May 2000
Construction/Loadline
Issued 8 May 2000 Resolved
RENEW AS ORIGINAL THE WASTED FRAMES NEAR THE LADDER OF THE #7 VOID SPACE. (3RD FRAME DOWN AND 2 DIAGONALS ADJOINING)
Condition: Unknown
Due 9 May 2000
Resolved 8 May 2000
Documentation
Issued 8 May 2000 Resolved
PROVIDE MASTER'S LICENSE.
Condition: Unknown
Due 17 May 2000
Resolved 8 May 2000
Documentation
Issued 8 May 2000 Resolved
PROVIDE EVIDENCE THAT 50% OF CREW COMPLIANCE WITH RED CROSS FIRST AID/CPR REQUIREMENT.
Condition: Unknown
Due 17 May 2000
Resolved 8 May 2000
Documentation
Issued 8 May 2000 Resolved
PROVIDE EVIDENCE THAT VESSEL COMPLIES WITH DRUG TESTING REQUIREMENTS.
Condition: Unknown
Due 17 May 2000
Resolved 8 May 2000
Accommodation/Occupational Safety
Issued 8 May 2000 Resolved
CLEARLY MARK THE MAXIMUM NUMBER OF PEOPLE ALLOWED ON UPPER DECK.
Condition: Unknown
Due 17 May 2000
Resolved 8 May 2000
Lifesaving
Issued 8 May 2000 Resolved
SEPARATE ADULT AND CHILD LIFEJACKETS VIA PARTITION.
Condition: Unknown
Due 17 May 2000
Resolved 8 May 2000
Lifesaving
Issued 8 May 2000 Resolved
STENCIL OVERHEAD LIFEJACKET STOWAGE AREA.
Condition: Unknown
Due 17 May 2000
Resolved 8 May 2000
Engineering
Issued 8 May 2000 Resolved
CLEARLY MARK REMOTE FUEL SHUT-OFF VALVE AS PER 46CFR122.608.
Condition: Unknown
Due 17 May 2000
Resolved 8 May 2000
Construction/Loadline
Issued 8 May 2000 Resolved
REPAIR #8 VOID SPACE BILGE SYSTEM CHECK VALVE AND DEMONSTRATE THAT BILGE PUMP SYSTEM FUNCTIONS PROPERLY.
Condition: Unknown
Due 17 May 2000
Resolved 8 May 2000
Electrical
Issued 15 May 1998 Resolved
Provide metal clamps for all wiring in engine room.
Condition: Unknown
Due 5 June 1998
Resolved 23 September 1998
Construction/Loadline
Issued 15 May 1998 Resolved
#7 hatch needs lanyard.
Condition: Unknown
Due 5 June 1998
Resolved 23 September 1998
Fire Fighting
Issued 15 May 1998 Resolved
Provide new fire hose nozzle.
Condition: Unknown
Due 5 June 1998
Resolved 23 September 1998
Construction/Loadline
Issued 15 May 1998 Resolved
Provide clamps for #4 port bilge suction (hose extension from bilge line).
Condition: Unknown
Due 5 June 1998
Resolved 23 September 1998
Engineering
Issued 15 May 1998 Resolved
Repair exhaust leaks in #6 hold.
Condition: Unknown
Due 5 June 1998
Resolved 23 September 1998
Lifesaving
Issued 15 May 1998 Resolved
Provide one adult and two small-stature PFDs.
Condition: Unknown
Due 5 June 1998
Resolved 23 September 1998
Electrical
Issued 15 May 1998 Resolved
Provide weathertight cover for 120V outlet at main deck._x001C_
Condition: Unknown
Due 5 June 1998
Resolved 23 September 1998
Construction/Loadline
Issued 15 May 1998 Resolved
Open check valves in bilge system for inspection.
Condition: Unknown
Due 20 June 1998
Resolved 23 September 1998
Construction/Loadline
Issued 15 May 1998 Resolved
Repair hole in starboard rudder post.
Condition: Unknown
Due 15 May 1998
Resolved 23 September 1998
Construction/Loadline
Issued 15 May 1998 Resolved
Inspect/repair all bilge line strainers.
Condition: Unknown
Due 20 June 1998
Resolved 23 September 1998
Electrical
Issued 15 May 1998 Resolved
Install deck light where missing between head entrances.
Condition: Unknown
Due 5 June 1998
Resolved 23 September 1998
Lifesaving
Issued 15 May 1998 Resolved
Remove foam insulation from vessel bulkheads.
Condition: Unknown
Due 5 June 1998
Resolved 23 September 1998
Navigation
Issued 15 May 1998 Resolved
Provide magnetic compass deviation card.
Condition: Unknown
Due 5 June 1998
Resolved 23 September 1998
Electrical
Issued 15 May 1998 Resolved
Provide permanent 12V standby power for PA system.
Condition: Unknown
Due 5 June 1998
Resolved 23 September 1998
Electrical
Issued 15 May 1998 Resolved
Mount power strip on bridge.
Condition: Unknown
Due 5 June 1998
Resolved 23 September 1998
Navigation
Issued 9 May 1997 Resolved
PROVIDE PROPER CHARTS FOR AREA.
Condition: Unknown
Due 12 May 1997
Resolved 8 July 1997
Navigation
Issued 9 May 1997 Resolved
PROVIDE RULES OF ROAD BOOK.
Condition: Unknown
Due 12 May 1997
Resolved 8 July 1997
Deck/Cargo
Issued 9 May 1997 Resolved
PROVIDE DAY SHAPE FOR ANCHORING.
Condition: Unknown
Due 12 May 1997
Resolved 8 July 1997
Lifesaving
Issued 9 May 1997 Resolved
PROVIDE ONE ADDITIONAL LIFE RING.
Condition: Unknown
Due 12 May 1997
Resolved 8 July 1997
Lifesaving
Issued 9 May 1997 Resolved
PROVIDE REFLECTIVE TAPE ON ALL LIFE RINGS.
Condition: Unknown
Due 12 May 1997
Resolved 8 July 1997
Lifesaving
Issued 9 May 1997 Resolved
PROVIDE 4 ADDITIONAL CHILD'S LIFE JACKETS.
Condition: Unknown
Due 12 May 1997
Resolved 8 July 1997
Accommodation/Occupational Safety
Issued 10 May 1996 Resolved
REPAIR PIPING ON STBD MF/W TANK.
Condition: Unknown
Due 25 August 1996
Resolved 10 September 1996
Accommodation/Occupational Safety
Issued 10 May 1996 Resolved
RENEW BROKEN WINDOW IN PORT SIDE HEAD DOOR.
Condition: Unknown
Due 25 August 1996
Resolved 10 September 1996
Construction/Loadline
Issued 10 May 1996 Resolved
RENEW HOSE CLAMPS ON BILGE SUCTION PIPING.
Condition: Unknown
Due 25 August 1996
Resolved 10 September 1996
Construction/Loadline
Issued 8 June 1993 Resolved
CROP & RENEW WASTED MAIN DECK & SIDESHELL STIFFNERS IN #6 VOID COMPARTMENT.
Condition: Unknown
Due 8 June 1993
Resolved 8 June 1993
Electrical
Issued 2 May 1990 Resolved
PROVIDE GUARDS FOR LIGHTS IN THE ENGINEROOM.
Condition: Unknown
Due 2 May 1990
Resolved 2 May 1990
Engineering
Issued 2 May 1990 Resolved
MARK BILGE PIPING MANIFOLD WITH LOCATION OF SUCTION FOR EACH VALVE.
Condition: Unknown
Due 2 May 1990
Resolved 2 May 1990
Lifesaving
Issued 2 May 1990 Resolved
PROVIDE SEVEN (07) ADULT TYPE I LIFE JACKETS, VESSEL IS LIMITED TO 203 TOTAL PERSONS ON BOARD UNTIL THIS REQUIREMENT IS COMPLETED.
Condition: Unknown
Due 2 May 1990
Resolved 2 May 1990
Electrical
Issued 23 June 1987 Resolved
EITHER REDUCE THE CIRCUIT BREAKERS TO 15 AMPS OR REWIRE THE SPOTLIGHT, HORN AND PILOT HOUSE LIGHTS WITH 12 AWG APPROVED ELECTRICAL CABLE IN ACCORDANCE WITH 46 CFR 183.05.
Condition: Unknown
Due 23 June 1987
Resolved 23 June 1987
Fire Fighting
Issued 23 June 1987 Resolved
IN ACCORDANCE WITH 46 CFR 181.30-10 PROVIDE A SUITABLE MOUNT FOR THE BII EXTINGUISHER.
Condition: Unknown
Due 23 June 1987
Resolved 23 June 1987
Construction/Loadline
Issued 23 June 1987 Resolved
IN ACCORDANCE WITH 46 CFR 171.119 SEAL THE 5/8" DIAM HOLE LEFT IN THE SIDE SHELL PLATING AT THE TOP PORT SIDE OF #6 VOID, LEFT BY THE REMOVAL OF A THROUGH HULL FITTING.
Condition: Unknown
Due 23 June 1987
Resolved 23 June 1987
Construction/Loadline
Issued 25 June 1986 Resolved
IN ACCORDANCE WITH 46 CFR 171.124 (D) INSTALL A COAMING AT LEAST 6 INCHES IN HEIGHT AT THE BASE OF THE DOOR TO THE ENGINE ROOM, IN THE COCKPIT.
Condition: Unknown
Due 25 June 1986
Resolved 25 June 1986
Construction/Loadline
Issued 25 June 1986 Resolved
IN ACCORDANCE WITH 46 CFR 171.124, PROVIDE CAPTIVE CHAINS OR SIMILAR DEVICEFOR EACH OF THE HATCH COVERS.
Condition: Unknown
Due 25 June 1986
Resolved 25 June 1986
Construction/Loadline
Issued 25 June 1986 Resolved
IN ACCORDANCE WITH 46 CFR 171.145 INSTALL SUFFICIENT FREEING PORTS TO PROVIDE REQUIRED DRAINAGE OF THE FORWARD ENCLOSED COCKPIT AREA.
Condition: Unknown
Due 25 June 1986
Resolved 25 June 1986
Construction/Loadline
Issued 25 June 1986 Resolved
PROVIDE VERIFICATION OF WEIGHT OF THE CONCRETE BALLAST CURRENTLY ABOARD THEVESSEL, TO THIS OFFICE, IN ORDER TO COMPLETE THE STABILITY REVIEW.
Condition: Unknown
Due 25 June 1986
Resolved 25 June 1986

Casualty record · 1

30 July 2023Routine · role: Involved in a Marine Casualty · activity 7814150
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record