MAURY USCG vessel records Sign in
← All vessels

CELTIC GRACE

CELTIC GRACE is a 1970 passenger vessel (inspected). The Coast Guard has recorded 71 inspections since 1985, most recently in April 2026, along with 178 deficiencies and 2 casualty investigations between 2010 and 2022.

Records from 1985 to 2026. Most recent: inspection, 27 April 2026.

Built
1970
Last inspected
27 April 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDH8721
Flag
UNITED STATES
367660850
Maury page id
psix-46547

Inspections, by type

…with no type recorded7
Years with a record 39 calendar years (1985–2026)
The 71 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)64.5 ft × 22.7 ft × 7.8 ft
Registered tonnagegross 87 / net 59
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderOUTER BANKS BOATWORKS INC · HARKER'S ISLAND, NC, UNITED STATES · built 1970
Hull materialWood
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portPORT JEFFERSON, NY
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 11 September 2025 · expires 31 October 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it87 - Regulatory (Subpart C or D), Gross Ton
59 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDH8721MMSI 367660850 · active · compulsorily equipped · granted 8 April 2025, expires 11 March 2035
WDG3512MMSI 367526820 · expired · compulsorily equipped · granted 21 April 2012, cancelled 25 June 2022 · licensed under a name not among this hull’s recorded names (not shown)
WDD3424MMSI 367131180 · expired · compulsorily equipped · granted 22 July 2006, cancelled 24 September 2016 · licensed under a name not among this hull’s recorded names (not shown)
WDC9462MMSI 367102590 · expired · compulsorily equipped · granted 28 March 2006, cancelled 28 May 2016 · licensed under a name not among this hull’s recorded names (not shown)
WCQ2092MMSI not assigned · expired · voluntarily equipped · granted 22 February 1995, cancelled 30 April 2005 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 71

27 April 2026 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8357652
17 March 2026 Drydock Exam · Internal Structural Exam · Examination of Repairs
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8327577
8 April 2025 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8106599
17 April 2024 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7896725
4 March 2024 Administrative Inspection · Drydock Exam · In-Service Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7871638
20 April 2023 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7658254
14 December 2022 Deficiency Check · Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7604401
16 October 2022 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7583423
20 April 2022 COI Inspection · DAPI Audit
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7411370
23 April 2021 DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7181181
14 December 2020 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7111749
7 July 2020 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6966922
16 April 2019 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6643292
7 December 2018 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6594715
2 September 2018 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6555200
23 July 2018 Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6488045
11 April 2018 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6361749
14 December 2017 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6317740
14 April 2017 Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6114437
19 November 2016 Type not recorded
No type recorded · Station New Haven · USCG Northeast District (CGD-NE) · Activity 6044519
12 April 2016 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 5852185
16 December 2015 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 5783180
15 May 2014 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 4856678
16 May 2012 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 4312873
24 August 2011 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 4124830
5 August 2008 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3286191
1 May 2008 Hull Examination · Internal Structural Exam · Examination of Repairs
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3196004
9 May 2007 COI Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2926231
21 July 2006 Administrative Inspection · Re-Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2720460
12 April 2006 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2622778
27 May 2005 Annual Inspection
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 2331872
8 June 2004 MARPOL Annex V Examination · Annual Inspection
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 2044712
15 April 2004 Hull Examination · Internal Structural Exam
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 2040093
2 June 2003 MARPOL Annex V Examination · Annual Inspection
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 1805612
15 April 2002 COI Inspection · MARPOL Annex V Examination
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 1604149
3 April 2002 Internal Structural Exam · Hull Examination
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 1599760
14 June 2001 Re-Inspection · MARPOL Annex V Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1431059
22 May 2000 MARPOL Annex V Examination · Re-Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1423378
27 March 2000 Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1450451
27 March 2000 Hull Examination · Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1471008
10 May 1999 Plan Review "T" Boat
Administrative · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 800443
4 March 1999 MARPOL Annex V Examination · COI Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1127950
22 January 1999 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 787020
8 May 1998 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1128810
23 March 1998 Re-Inspection · MARPOL Annex V Examination · Hull Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1411680
26 February 1997 MARPOL Annex V Examination · Re-Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1097339
31 March 1996 COI Inspection · MARPOL Annex V Examination · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1085803
27 February 1995 COI Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 853250
11 April 1994 MARPOL Annex V Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 859837
23 March 1994 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1169640
2 November 1993 Drydock Extension
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1159849
25 February 1993 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1151960
2 April 1992 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 948099
13 February 1992 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 948098
23 May 1991 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 945522
13 February 1991 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1219972
15 June 1990 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1213874
8 May 1990 Deficiency Check · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 919722
2 March 1990 Deficiency Check · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 927969
21 March 1989 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1201614
28 February 1989 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1349534
17 March 1988 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1036326
2 March 1988 COI Inspection · Hull Examination · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1340000
3 August 1987 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1336523
22 June 1987 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1313598
4 March 1987 COI Inspection · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1326955
6 February 1987 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1010424
18 March 1986 Credit Drydock
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1304560
5 March 1986 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1298127
13 March 1985 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1289493
8 March 1985 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 978002

Deficiency record · 178

05 - Radio Communications › N/A - No Subsystem › Operation/maintenance
Issued 8 April 2025 Resolved
Provide copy of FCC certs. FCC certs on board had expired.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 May 2025
Resolved 21 April 2025
Resolution: New certs
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 8 April 2025 Resolved
Provide copy of drills. Logbook was not on board the vessel at the time of the inspection.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 May 2025
Resolved 21 April 2025
Resolution: Provided.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 8 April 2025 Resolved
Forward masthead light was inop.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 May 2025
Resolved 21 April 2025
Resolution: Op.
09 - Working and Living Conditions › 092 - Working Conditions › Heating
Issued 8 April 2025 Resolved
Service boiler tri-annually. Boiler was not serviced.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 May 2025
Resolved 30 April 2025
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 8 April 2025 Resolved
Provide guard around Gennie.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 May 2025
Resolved 30 April 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 April 2025 Resolved
Replace life ring. Life ring was at the end of its serviceable lifespan.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 May 2025
Resolved 21 April 2025
Resolution: Replaced
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 April 2025 Resolved
Provide cover for light fixture in E/R.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 May 2025
Resolved 21 April 2025
Resolution: Replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 April 2025 Resolved
Replace PFD signage as appropriate.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 May 2025
Resolved 21 April 2025
Resolution: Replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 8 April 2025 Resolved
Collision bulkhead valve was inop.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 May 2025
Resolved 30 April 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 20 April 2023 Resolved
Repair collision compartment reach-rod for bilge suction valve.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 April 2023
Resolved 1 May 2023
Resolution: Received an attestment via e-mail that requirements had been resolved.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 20 April 2023 Resolved
Replace hydrostatic release for EPIRB prior to operating more than 3 miles from shore.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 20 April 2023
Resolved 1 May 2023
Resolution: Received an attestment via e-mail that requirements had been resolved.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 23 April 2021 Resolved
Logs and records must be maintained to ensure operational readiness of firefighting and life saving equipment. No records or maintenance could be verified. Established log record system with the vessel representative.
Action required: 10 - Deficiency Rectified
Due 23 April 2021
Resolved 23 April 2021
Resolution: Logs/ record system established
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 23 April 2021 Resolved
Float light for the port side life float was identified as potentially not water tight, missing a securing pin for the float light cap. Replace the float light associated with port life float
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 May 2021
Resolved 29 April 2021
Resolution: RCVD email with photo and receipt for a new float light purchased
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 23 April 2021 Resolved
The name of the vessel must be marked or painted in clearly legible letters on each life float paddle. No labeling on any of the three life float paddles (6 Paddles). Label paddles as required.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 May 2021
Resolved 28 April 2021
Resolution: Paddles Stencilled. RCVD photo evidence of such
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 23 April 2021 Resolved
The float free light must be designed to float free in case of a rapid emergency where manual deployment may not be possible. The float light associated with the center life float bracket was modified jamming the float light from floating free. Re-configure this life floats, float light to allow for float free configuration.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 May 2021
Resolved 26 April 2021
Resolution: The light bracket was modified by the O/O to allow for float free operations
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 23 April 2021 Resolved
EPIRB must be installed in a position to allow for float free operation. Currently the EPIRB is installed so low to the deck, that the cover cannot pop off and allow the EPIRB to float free. Re-configure EPIRB float free container.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 May 2021
Resolved 26 April 2021
Resolution: The EPIRB case was raised in order to allow for float free operations.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 23 April 2021 Resolved
Monthly EPIRB maintenance and check must be logged. Established record maintenance system with the O/O.
Action required: 10 - Deficiency Rectified
Due 23 April 2021
Resolved 23 April 2021
Resolution: Established log/ record system
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 23 April 2021 Resolved
Vessel first aid kit contents identified expired. Remove all expired contents from the first aid kit. Vessel representative replaces contents regularly and the required amount of contents not expired were on board.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 May 2021
Resolved 26 April 2021
Resolution: First Aid Kit contents expired were removed and replaced. RCVD phot of reciept for expired items.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 23 April 2021 Resolved
The EPIRB’s battery must be replaced prior to the date required by 47 CFR. Identified the EPIRB battery marking expired on 12/2018. Restrict operations to no more than 3 miles from shore until the EPIRB battery is replaced.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 April 2021
Resolved 26 April 2021
Resolution: New EPIRB purchased and registered.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 April 2019 Resolved
Provide a number of child size life jackets equal to at least 10% of the number of persons permitted on board. 46CFR108.71(a)
Action required: 17 - Rectify deficiencies prior to departure
Due 16 April 2019
Resolved 10 July 2019
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 16 April 2019 Resolved
Vessel did not have emergency instructions posted. 46CFR185.510
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 May 2019
Resolved 10 July 2019
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 11 April 2018 Resolved
Replace stbd CO2 bottle bracket.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 May 2018
Resolved 23 July 2018
Resolution: O/O installed new bracket
Communications › Radio Communications › VHF Radiotelephone
Issued 11 April 2018 Resolved
Program correct MMSI into VHF radio.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 May 2018
Resolved 23 July 2018
Resolution: O/O update MMSI # in DSC VHF
Communications › Radio Communications › VHF Radiotelephone
Issued 12 April 2016 Resolved
Install proper VHF-DSC radio equipment. 46 CFR 184.502 and 47 CFR 80.
Action required: 705 - Other - as specified
Due 28 April 2016
Resolved 21 April 2016
Lifesaving › Visual Distress Signals (General) › Not on Board
Issued 12 April 2016 Resolved
Provide 12 approved flares at operating station. (12 Hand red OR 6 red and 6 orange) 46 CFR 180.68 Prior to carrying passengers.
Action required: 705 - Other - as specified
Due 12 April 2016
Resolved 15 April 2016
Resolution: 12 Hand red flares provided on board.
Operations/Management › Drills/Instruction › Making Voice Radio Distress Call
Issued 12 April 2016 Resolved
Post emergency broadcast placard at operating station. 46 CFR 185.406
Action required: 705 - Other - as specified
Due 28 April 2016
Resolved 21 April 2016
Communications › Alarms/Indicators › Bilge Alarm
Issued 12 April 2016 Resolved
Prove proper operation of bilge high level alarm in forepeak. 46 CFR 182.530
Action required: 705 - Other - as specified
Due 28 April 2016
Resolved 15 April 2016
Electrical › Electrical Distribution System (service) › Wiring
Issued 12 April 2016 Resolved
Replace wire nuts on Bilge pump in lazarette with acceptable connectors. 46 CFR 183.340
Action required: 705 - Other - as specified
Due 28 April 2016
Resolved 15 April 2016
Lifesaving › Lifefloat › Paddle
Issued 12 April 2016 Resolved
Provide 2nd paddle for stbd life float (vessel has 3 LF's and 5 paddles, one more req'd) 46 CFR 160.010-8
Action required: 705 - Other - as specified
Due 28 April 2016
Resolved 15 April 2016
Lifesaving › Lifefloat › Markings
Issued 12 April 2016 Resolved
Label all paddles in lifefloats with vessel name. 46 CFR 185.604
Action required: 705 - Other - as specified
Due 28 April 2016
Resolved 15 April 2016
Construction/Loadline › Hull › Keel
Issued 21 December 2015 Resolved
Replaced wasted worm shoe PTCHE.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 January 2016
Resolved 12 January 2016
Resolution: Replaced the wasted worm shoes in the vincity of the keel.
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 21 December 2015 Resolved
Replace both MDE cutless bearings PTCHE
Action required: 705 - Other - as specified
Due 15 January 2016
Resolved 12 January 2016
Resolution: Both MDE Cutless Bearings were replaced.
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 21 December 2015 Resolved
Make proper repairs to both keel(port and stbd). Make keel coolers available for pressure test after completion of repairs.
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 January 2016
Resolved 12 January 2016
Resolution: Both keel(port and stbd) coolers have been made and have been pressure tested saftisfactory.
Construction/Loadline › Hull › Keel
Issued 21 December 2015 Resolved
Remove loose concrete patches and make repairs as per repair proposal.
Action required: 705 - Other - as specified
Due 15 January 2016
Resolved 12 January 2016
Resolution: The concrete patches have been removed and repairs have been made as per the repair proposal.
Engineering › Shafting/Propeller Arrangements › Stern Tube
Issued 21 December 2015 Resolved
Clean iva port stern tube in engroom/ Remove salt and trash.
Action required: 705 - Other - as specified
Due 15 January 2016
Resolved 12 January 2016
Resolution: The port stern tube in engroom has been repaired, all of the salt and trash has been removed.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 21 December 2015 Resolved
Install missing breakers in the engine room panel.
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 January 2016
Resolved 27 January 2016
Resolution: Breaker has been installed.
Construction/Loadline › Hull › Keel
Issued 21 December 2015 Resolved
Refasten AFT most portside keel.
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 January 2016
Resolved 12 January 2016
Resolution: The AFT most portside keel has been refastened.
Engineering › Steering Gear System › Pump
Issued 21 December 2015 Resolved
Hard wire water pump in the steering compartment.
Action required: 705 - Other - as specified
Due 21 January 2016
Resolved 27 January 2016
Resolution: Wash down pump has been hardwired in.
Operations/Management › Navigation Safety › Proper Use of Navigation/Anchor Lights
Issued 15 May 2014 Resolved
Properly install STB navigation light and cover. Limited to daylight operations and fair weather.
Action required: 705 - Other - as specified
Resolved 16 May 2014
Resolution: Light and cover replaced and in working order.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 15 May 2014 Resolved
Repair or replace 2 life float water lights. Restricted to day light operations.
Action required: 705 - Other - as specified
Resolved 16 May 2014
Resolution: Vsl o/o replaced lights with approved type. Route restrictions removed.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 15 May 2014 Resolved
Properly label life jacket storage in main cabin with correct number of PFD.
Due 15 June 2014
Resolved 24 June 2014
Resolution: Storage labeled.
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 15 May 2014 Resolved
Provide emergency broadcast placard at operation station.
Due 15 June 2014
Resolved 8 July 2014
Resolution: Broadcast placard installed.
Engineering › Bilge Water Management System › Hose
Issued 15 May 2014 Resolved
Repair leak in lazarette bilge pump hose. Vsl has a fixed bilge system, leak is on secondary pump.
Due 15 June 2014
Resolved 15 May 2014
Resolution: Leak in hose was corrected on the spot.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 15 May 2014 Resolved
Install blanks or covers in engine room curcuit board.
Due 15 June 2014
Resolved 24 June 2014
Resolution: Corrected.
Electrical › Electrical Distribution System (service) › Wiring
Issued 15 May 2014 Resolved
Secure hanging wires in engine room.
Due 15 June 2014
Resolved 24 June 2014
Resolution: Corrected.
Engineering › Fuel Oil Service System › Valve
Issued 15 May 2014 Resolved
Label emergency fuel shut off valve outside of space.
Due 15 June 2014
Resolved 24 June 2014
Resolution: Corrected.
Engineering › Bilge Water Management System › Manifold
Issued 15 May 2014 Resolved
Properly label bilge manifold in engine room.
Due 15 June 2014
Resolved 8 July 2014
Resolution: Manifold labeled.
Electrical › Electric Generation Source (service) › Panelboard
Issued 15 May 2014 Resolved
Properly label generator gauges on control panel in engine room.
Due 15 June 2014
Resolved 8 July 2014
Resolution: Gens labeled.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 15 May 2014 Resolved
Label manual pull instructions for fixed CO2 system at bottles.
Due 15 June 2014
Resolved 24 June 2014
Resolution: Corrected.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 24 August 2011 Resolved
Provide retro-reflective material for life jackets as needed.
Condition: Improper/Lack of Maintenance
Due 24 September 2011
Resolved 24 April 2012
Resolution: corrected. new tape fitted
Communications › Radio Communications › EPIRB
Issued 24 August 2011 Resolved
Provide a new hydrostatic release for float free arrangement prior to sailing more than 3 miles from shore.
Condition: Improper/Lack of Maintenance
Due 24 September 2011
Resolved 24 April 2012
Resolution: completed.
Lifesaving › Lifefloat › Paddle
Issued 24 August 2011 Resolved
Provide new paddles for L/F
Condition: Improper/Lack of Maintenance
Due 24 September 2011
Resolved 24 April 2012
Resolution: provided & secured to float.
Lifesaving › Lifefloat › Platform
Issued 24 August 2011 Resolved
Repair or replace platform in upper L/F and clean L/F
Condition: Improper/Lack of Maintenance
Due 24 September 2011
Resolved 24 April 2012
Resolution: Repaired.
Lifesaving › Lifefloat › Float Free
Issued 24 August 2011 Resolved
Prove proper float free arrangement
Condition: Placed in Improper Service
Due 24 September 2011
Resolved 24 April 2012
Resolution: Set up IAW NVIC 1-83
Communications › Alarms/Indicators › Bilge Alarm
Issued 24 August 2011 Resolved
Prove proper operation of high water alarms in engine room and LAZZ
Condition: Improper/Lack of Maintenance
Due 24 September 2011
Resolved 24 April 2012
Resolution: All highwater alarms tested.
Engineering › Bilge Water Management System › Pump
Issued 24 August 2011 Resolved
prove proper operation of bilge pump in LAZZ
Condition: Improper/Lack of Maintenance
Due 24 September 2011
Resolved 24 April 2012
Resolution: Tested sat
Electrical › Electrical Distribution System (service) › Wiring
Issued 24 August 2011 Resolved
Remove dead end cables in LAZ
Condition: Improper/Lack of Maintenance
Due 24 September 2011
Resolved 24 April 2012
Resolution: Completed
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 24 August 2011 Resolved
properly mount/secure stbd exhaust pipe
Condition: Improper Installation
Due 24 September 2011
Resolved 24 April 2012
Resolution: Completed
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 24 August 2011 Resolved
renew hose clamps on exhaust pipes
Condition: Improper Installation
Due 24 September 2011
Resolved 24 April 2012
Resolution: Completed
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 24 August 2011 Resolved
Provide proof of servicing all fire extinguishers
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 August 2011
Resolved 24 April 2012
Resolution: Renewed and/or serviced all extinguishers
Fire Fighting › Fire Main › Condition
Issued 24 August 2011 Resolved
Repair or replace hose clamp on Fire main near overboard discharge.
Condition: Improper/Lack of Maintenance
Due 24 September 2011
Resolved 24 April 2012
Resolution: Tested during fire drill
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 24 August 2011 Resolved
replace broken outlet covers.
Condition: Improper/Lack of Maintenance
Due 24 September 2011
Resolved 24 April 2012
Resolution: Completed
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 24 August 2011 Resolved
properly mount vending machines to prevent tipping.
Condition: Placed in Improper Service
Due 24 September 2011
Resolved 24 April 2012
Resolution: completed
Lifesaving › Lifebuoys › Serviceable
Issued 24 August 2011 Resolved
replace L/R buoy on stbd side
Condition: Placed in Improper Service
Due 24 September 2011
Resolved 24 April 2012
Resolution: R/B replaced.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 24 August 2011 Resolved
provide a belt guard for aft generator
Condition: Placed in Improper Service
Due 24 September 2011
Resolved 24 April 2012
Resolution: completed
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 24 August 2011 Resolved
provide a belt guard for STBD MDE
Condition: Placed in Improper Service
Due 24 September 2011
Resolved 24 April 2012
Resolution: completed
Documentation › Markings/Placards › Capacity Marking
Issued 24 August 2011 Resolved
Upper deck is limited to 30 persons, post upper deck limitation
Condition: Improper/Lack of Maintenance
Due 24 September 2011
Resolved 24 April 2012
Resolution: corrrected
Electrical › Lighting (service) › Switch
Issued 24 August 2011 Resolved
repair light switch cover and remount fixture
Condition: Improper/Lack of Maintenance
Due 24 September 2011
Resolved 24 April 2012
Resolution: Completed
Personnel › Training › Fire Fighting Basic
Issued 24 August 2011 Resolved
conduct satisfactory MOB and firefighting drills in the presence of a CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 August 2011
Resolved 24 April 2012
Resolution: Drills conducted sat
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 24 August 2011 Resolved
Provide proof of DAPI enrollment
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 August 2011
Resolved 24 April 2012
Resolution: Completed sat. Vessel operated by same crew from owners previous vessel.
Electrical › Lighting (service) › Lighting Fixture
Issued 5 August 2008 Resolved
replace missing screw plug on electrical box for aft port deck light on pilothouse.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 August 2008
Resolved 13 August 2008
Resolution: Completed.
Lifesaving › Hand Flares › Expired
Issued 5 August 2008 Resolved
Replace six expired hand distress signals.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 August 2008
Resolved 5 August 2008
Resolution: Replaced during inspection.
Engineering › Steering Gear System › Fastener
Issued 5 August 2008 Resolved
Secure loose foundation bolts for Kainer steering gear.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 August 2008
Resolved 5 August 2008
Resolution: Bolts removed and new bolts, washers, and nuts fitted to secure the gear frame to the foundation plank during the exam. Tested & found satisfactory.
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 5 August 2008 Resolved
Remark child PFD storage.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 August 2008
Resolved 13 August 2008
Resolution: All storage containers remarked after paint out of space.
Engineering › Shafting/Propeller Arrangements › Stern Tube
Issued 1 May 2008 Resolved
Owner is having yard open stbd shaft tube and remove for exam based upon wear found & repaired for port shaft tube at the last drydocking. Examnation indicated that the shaft has been running off ctr in the shaft tube and may have worn the tube thin on the lower edge.
Action required: 705 - Other - as specified
Due 30 May 2008
Resolved 14 May 2008
Resolution: Opened, examined & found sat.
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 1 May 2008 Resolved
Port & Stbd strut bearing worn. Monofilament fishing line caught in shaft worked into bearing. Remove the fish line & examine bearings for wear. Replace as necessary.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 May 2008
Resolved 14 May 2008
Resolution: Stbd found sat. Port found worn & renewed.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 1 May 2008 Resolved
Present port shaft for examination when pulled. Owner is pulling shaft as part of the shaft tube examination & repair project.
Action required: 705 - Other - as specified
Due 30 May 2008
Resolved 14 May 2008
Resolution: Shaft found sat.
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 1 May 2008 Resolved
This is the completion of the owner's first operating period w/ the vessel. He noted that the engines were loaded unevenly and determined that the propellers are mismatched in size & pitch. He plans to recon the props and match them during this drydocking.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 May 2008
Resolved 30 May 2008
Resolution: Port prop recond & cut dia & repitched to 32 X 32 to match stbd prop. This was original size on vessel when built. Stbd prop recond.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 1 May 2008 Resolved
Collision bhd galvanized steel nail fasteners found failing. Bhd battens found loose. Refasten collision bhd and caulk and secure battens in place to regain watertight integrity of bhd.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 May 2008
Resolved 12 June 2008
Resolution: Bhd refastened & battens secured & caulked.
Construction/Loadline › Structures › Deck Plating
Issued 1 May 2008 Resolved
Remove rotted deck planking on foredeck, examine underdeck structues and repair as necessary. Owner plans to replace rotted section of fwd deck w/ marine plywood sheathed with epoxy FRP.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 May 2008
Resolved 12 June 2008
Resolution: Planking removed from 8'' X 8'' section of foredeck. New decking fitted; 2 layers of 3/4" marine plywood fastened w/ 2-3/8" ss ring nails on first layer. FRP laminate fitted between & above plywood.
Construction/Loadline › Hull › Side Shell
Issued 1 May 2008 Resolved
Stbd rubrail IWO compt #2 fractured & worn from wear against piling over prior seasons. Crop & renew.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 May 2008
Resolved 30 May 2008
Resolution: Stbd rub rail was removed from scarf joint behind damage, for a length of approx. ten feet.
Engineering › Bilge Water Management System › Valve
Issued 1 May 2008 Resolved
Repair reach rod & valve in forepeak for control of bilge suction.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 May 2008
Resolved 30 May 2008
Resolution: Renewed.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 1 May 2008 Resolved
Close all unused wire & piping penetrations in the watertight bhds. (Note: Owner has been removing out of service wiring and piping that was replace over prior years of operation due to wear & tear of normal ops. The work progressed during winter lay-up and several of the penetrations remain to be closed.)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 May 2008
Resolved 30 May 2008
Resolution: Completed.
Construction/Loadline › Structures › Ventilators
Issued 1 May 2008 Resolved
Multiple vents thru the maindeck IWO of the covering board and leading up thru the bulwarks were found to be missing a batten to close them to the weather at the deck level on the outboard side of the bulwarks. Owner is fabricating new vent parts to correct the lack of watertight integrity within the vents. (Vessel restricted to protected waters.) Opening must be 12" or more above deck.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 May 2008
Resolved 30 May 2008
Resolution: Completed.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 9 May 2007 Resolved
Repair stern light prior to operating at night.
Due 17 May 2007
Resolved 17 May 2007
Resolution: Repaired stern light.
Electrical › Electrical Distribution System (service) › Wiring
Issued 9 May 2007 Resolved
Remove all dead end wires throughout the vessel
Due 17 May 2007
Resolved 17 May 2007
Resolution: Removed all dead end wires throughout the vessel
Communications › Public Address System › Loudspeaker
Issued 9 May 2007 Resolved
Make necessary repairs to public address system.
Due 17 May 2007
Resolved 17 May 2007
Resolution: Made necessary repairs to public address system.
Communications › Alarms/Indicators › Bilge Alarm
Issued 9 May 2007 Resolved
Repair bildge high water alarm in forward compartment prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 June 2007
Resolution: Repaired bildge high water alarm in forward compartment.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 9 May 2007 Resolved
Properly label 12v panel in pilot house.
Due 17 May 2007
Resolved 17 May 2007
Resolution: Properly labeled 12v panel in pilot house.
Lifesaving › Lifefloat › Serviceable
Issued 9 May 2007 Resolved
Rearrange lifefloats as discussed and properly label paddles and secure to lifefloats.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 May 2007
Resolution: Rearranged lifefloats as discussed and properly labeled paddles and secured to lifefloats.
Lifesaving › Lifebuoys › Serviceable
Issued 9 May 2007 Resolved
Properly patch or replace port side lifering.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 May 2007
Resolution: Replaced port side lifering with new one.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 9 May 2007 Resolved
Provide one new adult lifejacket, and provide new retroflective material on several jackets
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 May 2007
Resolution: Provided one new adult lifejacket, and placed new retroflective material on several jackets.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 9 May 2007 Resolved
Properly mount all portable fire extinguishers with CG approved brackets.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 May 2007
Resolution: Properly mounted all portable fire extinguishers with CG approved brackets.
Electrical › Lighting (service) › Lighting Fixture
Issued 9 May 2007 Resolved
Provide light covers and guards for three lights in engineroom.
Due 17 May 2007
Resolved 17 May 2007
Resolution: Provided light covers and guards for three lights in engineroom.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 9 May 2007 Resolved
Provide blanks for breaker panel in engine room on forward bulkhead.
Due 17 May 2007
Resolved 17 May 2007
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 27 May 2005 Resolved
Provide valid enrollment in a drug and alcohol consurtium.
Due 10 June 2005
Resolved 20 June 2005
Lifesaving › Lifefloat › Float-free Link
Issued 27 May 2005 Resolved
Connect 3 weak links for LF to vsl.
Due 10 June 2005
Resolved 20 June 2005
Engineering › Sea-water System (primary cooling) › Piping
Issued 27 May 2005 Resolved
Repair water leak through exhaust pipe in the lazerette. Damage to inboard port piping near forward bulkhead.
Due 10 June 2005
Resolved 20 June 2005
Deck/Cargo › Holds/Tanks › Hatch
Issued 27 May 2005 Resolved
Permanently connect hatches to vsl.
Due 10 June 2005
Resolved 20 June 2005
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 27 May 2005 Resolved
Update first aid kit.
Due 10 June 2005
Resolved 27 June 2005
Lifesaving › Lifefloat › Paddle
Issued 27 May 2005 Resolved
Replcae/ Reattach paddles to lifefloats.
Due 10 June 2005
Resolved 20 June 2005
Communications › Alarms/Indicators › Bilge Alarm
Issued 15 April 2002 Resolved
Prove proper operation of high level bilge alarms in all compartments. Label panels.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 April 2002
Resolution: Proved proper operation. Panel labeled.
Personnel › Training › Search and Rescue
Issued 15 April 2002 Resolved
Conduct drills and training prior to first trip w/ passengers. Provide proof of drills/training for 3 months ending 15 Jul 02.
Condition: Unknown
Due 15 July 2002
Resolved 24 July 2002
Resolution: Verified log book w/ training records.
Lifesaving › Buoyant Apparatus
Issued 15 April 2002 Resolved
Replace wasted wood platforms on 2 of the 3 lifefloats. Vessel restricted to 1 mile from shore until corrected.
Condition: Improper/Lack of Maintenance
Due 15 May 2002
Resolved 25 April 2002
Resolution: New wood placed in life floats.
Lifesaving › Buoyant Apparatus
Issued 15 April 2002 Resolved
Renew line that holds board in 3rd lifefloat. Vessel restricted to no more than 1 nm from shore until corrected.
Condition: Improper/Lack of Maintenance
Due 15 May 2002
Resolved 25 April 2002
Resolution: New line put in service.
Lifesaving › Buoyant Apparatus
Issued 15 April 2002 Resolved
Stencil vessel name on fire ax, life float paddles and ringbuoy.
Condition: Improper Installation
Due 15 May 2002
Resolved 25 April 2002
Resolution: Name stenciled w/ black block letters.
Engineering › Diesel Engine (propulsion-electric)
Issued 15 April 2002 Resolved
Renew/repair bridge RPM guage on bridge.
Due 15 May 2002
Resolved 9 May 2002
Resolution: New digital guage installed.
Communications › Radio Communications › EPIRB
Issued 15 April 2002 Resolved
Renew hydrostatic release for EPIRB. Vessel restricted to no further than 3nm from shore until complete.
Condition: Improper/Lack of Maintenance
Due 15 May 2002
Resolved 8 May 2002
Resolution: New release installed.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 15 April 2002 Resolved
Renew aspirin & eyewash in first aid kit. Remove expired items.
Due 15 May 2002
Resolved 25 April 2002
Resolution: Items purchased.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 15 April 2002 Resolved
Provide tides and tidal current tables.
Condition: Improper/Lack of Maintenance
Due 15 May 2002
Resolved 30 April 2002
Resolution: Purchased Eldridge''s for CY02.
Communications › Radio Communications
Issued 15 April 2002 Resolved
Change radio station license to current vessel name. LEGACY COMPONENT DESC: VFH Radiotelephone
Due 15 May 2002
Resolved 2 June 2003
Communications › Radio Communications
Issued 15 April 2002 Resolved
Renew safety telephony certificate. Vessel restricted to no further than 1000 ft from shore until corrected. LEGACY COMPONENT DESC: VFH Radiotelephone
Due 15 May 2002
Resolved 2 June 2003
Engineering › Fuel Oil Service System
Issued 15 April 2002 Resolved
Restencil fuel shutoff locations.
Condition: Improper/Lack of Maintenance
Due 15 May 2002
Resolved 25 April 2002
Resolution: Restenciled.
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 15 April 2002 Resolved
Repair toilet in men's head.
Due 15 May 2002
Resolved 10 May 2002
Resolution: Toilet replaced.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 15 April 2002 Resolved
Service portable fire extinguishers.
Condition: Improper/Lack of Maintenance
Due 15 May 2002
Resolved 2 May 2002
Resolution: Serviced by Firematic.
Accommodation/Occupational Safety
Issued 14 June 2001 Resolved
PROVIDE AND POST EMERGENCY INSTRUCTIONS.
Condition: Unknown
Due 30 June 2001
Resolved 12 October 2001
Engineering
Issued 14 June 2001 Resolved
REPAIR EXHAUST LEAK ON INBOARD MUFFLER IN STBD STEERING COMPARTMENT.
Condition: Unknown
Due 30 June 2001
Resolved 12 October 2001
Lifesaving
Issued 14 June 2001 Resolved
REPLACE RETRO REFLECTIVE TAPE ON LIFEJACKETS.
Condition: Unknown
Due 30 June 2001
Resolved 12 October 2001
Lifesaving
Issued 14 June 2001 Resolved
PROVIDE RETRO-REFLECTIVE TAPE FOR LIFERINGS.
Condition: Unknown
Due 30 June 2001
Resolved 12 October 2001
Fire Fighting
Issued 10 May 1999 Resolved
CONDUCT INSTALLATION INSPECTION AND TEST OF FIXED CO2/FIRE DETECTION SYSTEM/PIPING.
Condition: Unknown
Due 10 May 1999
Resolved 10 May 1999
Lifesaving
Issued 23 March 1998 Resolved
ALL RING BUOYS MUST BE INTERNATIONAL ORANGE.
Condition: Unknown
Due 16 July 1998
Resolved 16 July 1998
Construction/Loadline
Issued 23 March 1998 Resolved
RESECURE REACH ROD FOR COLLISION BHD BILGE SUCTION VALVE.
Condition: Unknown
Due 23 March 1998
Resolved 23 March 1998
Engineering
Issued 23 March 1998 Resolved
REWRAP OUTBOARD EXHAUST PIPES FOR BOTH MDE W/ LAGGING.
Condition: Unknown
Due 23 March 1998
Resolved 23 March 1998
Lifesaving
Issued 23 March 1998 Resolved
CLEAN OIL FROM BILGES.
Condition: Unknown
Due 23 March 1998
Resolved 23 March 1998
Engineering
Issued 23 March 1998 Resolved
RENEW HANDLE FOR STBD FUEL CONTROL VALVE AT FWD BHD OF ENGINE SPACE.
Condition: Unknown
Due 23 March 1998
Resolved 23 March 1998
Unknown
Issued 23 March 1998 Resolved
PROVIDE A HANGER FOR SINK DRAIN PIPING STBD SIDE FWD ON OVERHEAD OF ENGINE SPACE.
Condition: Unknown
Due 23 March 1998
Resolved 23 March 1998
Lifesaving
Issued 23 March 1998 Resolved
PROVIDE 3 BRACKETS FOR WATERLIGHTS. (BRACKETS ON TOP OF WHEELHOUSE ARE WORN OUT.)
Condition: Unknown
Due 23 March 1998
Resolved 23 March 1998
Lifesaving
Issued 23 March 1998 Resolved
CLEAN PFDS.
Condition: Unknown
Due 23 March 1998
Resolved 23 March 1998
Lifesaving
Issued 23 March 1998 Resolved
PROVIDE TWO PADDLES FOR LIFE FLOATS.
Condition: Unknown
Due 23 March 1998
Resolved 23 March 1998
Lifesaving
Issued 23 March 1998 Resolved
RENEW WORN LINE HOLDING DROP NET IN STBD LIFE FLOAT.
Condition: Unknown
Due 23 March 1998
Resolved 23 March 1998
Lifesaving
Issued 23 March 1998 Resolved
RENEW PENDANTS WHICH ARE SUN DRIED ON STBD LIFE FLOAT.
Condition: Unknown
Due 23 March 1998
Resolved 23 March 1998
Engineering
Issued 23 March 1998 Resolved
TEST ALL MACHINERY, STEERING, PUMPS AND ALARMS WHEN VESSEL IS REFLOATED.
Condition: Unknown
Due 23 March 1998
Resolved 23 March 1998
Electrical
Issued 23 March 1998 Resolved
SECURE WIRING HARNESS FOR THE 20 KW NORTHERN LIGHTS GEN SET SO THAT IS OUT OF THE BILGE AND NOT WHERE IT CAN BE DAMAGED BY CREW WALKING BY OR BE TRIPPED OVER.
Condition: Unknown
Due 23 March 1998
Resolved 23 March 1998
Electrical
Issued 23 March 1998 Resolved
RESECURE PVC WIRING CONDUIT PORT SIDE IWO SWITCHBOARD.
Condition: Unknown
Due 23 March 1998
Resolved 23 March 1998
Electrical
Issued 26 February 1997 Resolved
REPAIR WASTED SECTION OF EXHAUST PIPING ON 2-71 GMC DIESEL AND INSTALL LAGGING ON THE UNCOOLED SECTION.
Condition: Unknown
Due 26 February 1997
Resolved 26 February 1997
Construction/Loadline
Issued 26 February 1997 Resolved
CROP OUT DETERIORATED WOOD AT STRUT BOLTS AND REPAIR. ( A WELL FITTED GRAVING BLOCK/DUTCHMAN GLUES W/ EPOXY IS ACCEPTABLE FOR REPAIR.)
Condition: Unknown
Due 26 February 1997
Resolved 26 February 1997
Lifesaving
Issued 26 February 1997 Resolved
RENEW WORN LINES FOR DROP BASKET IN LIFE FLOATS.
Condition: Unknown
Due 26 February 1997
Resolved 26 February 1997
Lifesaving
Issued 26 February 1997 Resolved
PROVIDE FCC EMERGENCY INSTRUCTION PLACARD AT THE BRIDGE RADION STATION.
Condition: Unknown
Due 26 February 1997
Resolved 26 February 1997
Navigation
Issued 26 February 1997 Resolved
MOVE DECK LICHTS OR SIDELIGHTS SO THAT THEY DO NOT INTERFER W/ EACH OTHER.
Condition: Unknown
Due 26 February 1997
Resolved 26 February 1997
Electrical
Issued 26 February 1997 Resolved
DEMONSTRATE OPERATION OF THE REPLACEMENT NORTHERN LIGHTS GENSET.
Condition: Unknown
Due 26 February 1997
Resolved 26 February 1997
Documentation
Issued 26 February 1997 Resolved
RENEW FCC RADIOTELEPHONE SAFETY CERTIFICATE. CURRENT CERT EXPIRES 7APR97.
Condition: Unknown
Due 26 February 1997
Resolved 26 February 1997
Electrical
Issued 26 February 1997 Resolved
PROVIDE DRIP SHIELDS ON ENGINE ROOM ELECTRICAL SWITCHBOARDS AND PANELS.
Condition: Unknown
Due 26 February 1997
Resolved 26 February 1997
Engineering
Issued 11 April 1994 Resolved
REINSTALL & PROVE PROPER OPERATION OF ONAN GENERATOR.
Condition: Unknown
Due 11 April 1994
Resolved 11 April 1994
Documentation
Issued 2 November 1993 Resolved
DRYDOCK VESSEL FOR EXAMINATION NOT LATER THAN 31JAN94. A (3) THREE MONTH EXTENTION OF THE DRYDOCK INTERNAL HAS BEEN GRANTED EFFECTIVE 31OCT93.
Condition: Unknown
Due 2 November 1993
Resolved 2 November 1993
Engineering
Issued 13 February 1991 Resolved
REPLACE LEAKING SEAL ON STBD ENGINE H20 PUMP_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 13 February 1991
Resolved 13 February 1991
Engineering
Issued 13 February 1991 Resolved
RENEW END FITTING ON CLUTCH CONTROL CABLE FOR STBD ENG.
Condition: Unknown
Due 13 February 1991
Resolved 13 February 1991
Lifesaving
Issued 13 February 1991 Resolved
RENEW BATTERY IN WATERLIGHT FOR LIFE FLOAT.
Condition: Unknown
Due 13 February 1991
Resolved 13 February 1991
Engineering
Issued 13 February 1991 Resolved
REPLACE WASTED EXHAUST PIPES AND RISER._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 13 February 1991
Resolved 13 February 1991
Lifesaving
Issued 13 February 1991 Resolved
RENEW PENDANTS ON LIFE FLOATS AND REMARK LIFE FLOATS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 13 February 1991
Resolved 13 February 1991
Fire Fighting
Issued 13 February 1991 Resolved
RENEWED BOTH FIRE HOSES._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 13 February 1991
Resolved 13 February 1991
Accommodation/Occupational Safety
Issued 13 February 1991 Resolved
RECAULK STEM TO SIDE PLANKING JOINT_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 13 February 1991
Resolved 13 February 1991
Engineering
Issued 13 February 1991 Resolved
REPLACE BROKEN STRAINER ON BILGE SUCTION IN #2 COMPT. AND CLEAN BILGE IN FWD COMPT.
Condition: Unknown
Due 13 February 1991
Resolved 13 February 1991
Construction/Loadline
Issued 8 May 1990 Resolved
RENEWED WOOD ALKALI / ELECTROLYSIS DAMAGED SECTIONS OF WOOD IN WAY OF SHAFTTUBES.
Condition: Unknown
Due 8 May 1990
Resolved 8 May 1990
Construction/Loadline
Issued 8 May 1990 Resolved
RECAULKED FOREDECK.
Condition: Unknown
Due 8 May 1990
Resolved 8 May 1990
Construction/Loadline
Issued 8 May 1990 Resolved
RENEWED WORM EATEN SECTION OF STERN FRAME AT AFT END OF KEEL.
Condition: Unknown
Due 8 May 1990
Resolved 8 May 1990
Construction/Loadline
Issued 8 May 1990 Resolved
BURNED OUT AND TREATED W/ EPOXY WORM INFESTED AREAS ALONG LOWER SECTION OF THE KEEL.
Condition: Unknown
Due 8 May 1990
Resolved 8 May 1990
Construction/Loadline
Issued 8 May 1990 Resolved
RENEWED AFT SECTION OF DECKHOUSE OVERHEAD.
Condition: Unknown
Due 8 May 1990
Resolved 8 May 1990
Construction/Loadline
Issued 8 May 1990 Resolved
REPAIRED WOOD ALKALI / ELECTROLYSIS DAMAGE TO AFT BHD OF MACHINERY SPACE AND NECT BHD AFT IN WAY OF CU BILGE PIPING PENETRATION & REFASTENED LOWER SECTION OF BHDS.
Condition: Unknown
Due 8 May 1990
Resolved 8 May 1990
Navigation
Issued 2 March 1990 Resolved
REPLACE SIDE LIGHTS W/ LIGHTS ACCEPTABLE UNDER COL-REGS FOR A VESSEL OVER 20 METERS.
Condition: Unknown
Due 2 March 1990
Resolved 2 March 1990
Unknown
Issued 2 March 1990 Resolved
CONDUCT AN UNDERWAY EXAM.
Condition: Unknown
Due 2 March 1990
Resolved 2 March 1990
Lifesaving
Issued 2 March 1990 Resolved
RENEW WORN LIFELINES AND PENDANTS / PAINT AND REMARK LIFE FLOATS.
Condition: Unknown
Due 2 March 1990
Resolved 2 March 1990
Lifesaving
Issued 2 March 1990 Resolved
REPLACE THREE PFD'S ( ADULT )
Condition: Unknown
Due 2 March 1990
Resolved 2 March 1990
Lifesaving
Issued 2 March 1990 Resolved
RENEW WORN RING BUOYS.
Condition: Unknown
Due 2 March 1990
Resolved 2 March 1990
Engineering
Issued 2 March 1990 Resolved
PROVE OPERATION OF STBD MDE AND ITS RELATED PUMPS AND CONTOLS.
Condition: Unknown
Due 2 March 1990
Resolved 2 March 1990
Unknown
Issued 2 March 1990 Resolved
RENEW WASTED HEATER FLUE PIPE. HEATER OUT OF SERVICE UNTIL REPAIRS MADE.
Condition: Unknown
Due 2 March 1990
Resolved 2 March 1990
Electrical
Issued 2 March 1990 Resolved
REPAIR OR REMOVE ONAN AUX GENERATOR.
Condition: Unknown
Due 2 March 1990
Resolved 2 March 1990
Engineering
Issued 28 February 1989 Resolved
REPAIR BILGE ALARM SENSORS.
Condition: Unknown
Due 28 February 1989
Resolved 28 February 1989
Electrical
Issued 28 February 1989 Resolved
LINE FORWARD BATTERY MOUNT GENERATOR STARTING BANK WITH LEAD OR FRP.
Condition: Unknown
Due 28 February 1989
Resolved 28 February 1989
Fire Fighting
Issued 28 February 1989 Resolved
RECHARGE DRY CHEMICAL BCII FIRE EXTINGUISHER PRIOR TO GETTING UNDERWAY BUT 03MAR89.
Condition: Unknown
Due 28 February 1989
Resolved 28 February 1989
Lifesaving
Issued 28 February 1989 Resolved
LABEL FIRE AXE AND BOUYANT APPARATUS PADDLES WITH VESSEL'S NAME.
Condition: Unknown
Due 28 February 1989
Resolved 28 February 1989
Fire Fighting
Issued 2 March 1988 Resolved
HYDRO TEST BOTH B-II CO2 PORTABLE EXTINGUISHERS.
Condition: Unknown
Due 2 March 1988
Resolved 2 March 1988
Lifesaving
Issued 2 March 1988 Resolved
PROVIDE ADDITIONAL REFLECTIVE TAPE ON THE BACK OF 24 ADULT PFD'S.
Condition: Unknown
Due 2 March 1988
Resolved 2 March 1988
Navigation
Issued 4 March 1987 Resolved
REPOSITION NAV LIGHTS TO CONFORM WITH COLREGS
Condition: Unknown
Due 4 March 1987
Resolved 4 March 1987
Engineering
Issued 4 March 1987 Resolved
PROVIDE OPERATION OF HIGH TEMP ALARMS ON BOTH MAIN ENGINES.
Condition: Unknown
Due 4 March 1987
Resolved 4 March 1987
Electrical
Issued 4 March 1987 Resolved
PROVE PROPER OPERATION OF 110 VAC ON AN AUX GENERATOR.
Condition: Unknown
Due 4 March 1987
Resolved 4 March 1987
Electrical
Issued 4 March 1987 Resolved
PROVE PROPER OPERATION OF OVERSPEED TRIPS ON 110 VAC AUX GENERATOR.
Condition: Unknown
Due 4 March 1987
Resolved 4 March 1987
Electrical
Issued 4 March 1987 Resolved
REMOVE SMALL WIRE FROM FM RADIO FROM 12V BATTERY AND RECONNECT AFTER MAIN DISCONNECT AND PROVIDE OUVERCURRENT PROTECTION.
Condition: Unknown
Due 4 March 1987
Resolved 4 March 1987
Lifesaving
Issued 4 March 1987 Resolved
PROVIDE ADDITIONAL REFLECTIVE MATERIAL ON THE BACK OF ALL LIFE PRESERVERS.
Condition: Unknown
Due 4 March 1987
Resolved 4 March 1987

Casualty record · 2

25 May 2010Routine · role: Involved in a Marine Casualty · activity 3761127
16 October 2022Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 7583423
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

TRADEWINDS II (2010). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record