Inspection history · 21
27 April 2026
Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8357652
17 March 2026
Drydock Exam · Internal Structural Exam · Examination of Repairs
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8327577
8 April 2025
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8106599
17 April 2024
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7896725
4 March 2024
Administrative Inspection · Drydock Exam · In-Service Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7871638
20 April 2023
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7658254
14 December 2022
Deficiency Check · Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7604401
16 October 2022
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7583423
20 April 2022
COI Inspection · DAPI Audit
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7411370
23 April 2021
DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7181181
14 December 2020
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7111749
7 July 2020
Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6966922
16 April 2019
Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6643292
7 December 2018
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6594715
2 September 2018
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6555200
23 July 2018
Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6488045
11 April 2018
Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6361749
14 December 2017
Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6317740
14 April 2017
Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6114437
19 November 2016
Type not recorded
No type recorded · Station New Haven · USCG Northeast District (CGD-NE) · Activity 6044519
12 April 2016
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 5852185
05 - Radio Communications › N/A - No Subsystem › Operation/maintenance
Issued 8 April 2025
Resolved
Provide copy of FCC certs. FCC certs on board had expired.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 May 2025
Resolved 21 April 2025
Resolution: New certs
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 8 April 2025
Resolved
Provide copy of drills. Logbook was not on board the vessel at the time of the inspection.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 May 2025
Resolved 21 April 2025
Resolution: Provided.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 8 April 2025
Resolved
Forward masthead light was inop.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 May 2025
Resolved 21 April 2025
Resolution: Op.
09 - Working and Living Conditions › 092 - Working Conditions › Heating
Issued 8 April 2025
Resolved
Service boiler tri-annually. Boiler was not serviced.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 May 2025
Resolved 30 April 2025
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 8 April 2025
Resolved
Provide guard around Gennie.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 May 2025
Resolved 30 April 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 April 2025
Resolved
Replace life ring. Life ring was at the end of its serviceable lifespan.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 May 2025
Resolved 21 April 2025
Resolution: Replaced
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 April 2025
Resolved
Provide cover for light fixture in E/R.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 May 2025
Resolved 21 April 2025
Resolution: Replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 April 2025
Resolved
Replace PFD signage as appropriate.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 May 2025
Resolved 21 April 2025
Resolution: Replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 8 April 2025
Resolved
Collision bulkhead valve was inop.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 May 2025
Resolved 30 April 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 20 April 2023
Resolved
Repair collision compartment reach-rod for bilge suction valve.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 April 2023
Resolved 1 May 2023
Resolution: Received an attestment via e-mail that requirements had been resolved.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 20 April 2023
Resolved
Replace hydrostatic release for EPIRB prior to operating more than 3 miles from shore.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 20 April 2023
Resolved 1 May 2023
Resolution: Received an attestment via e-mail that requirements had been resolved.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 23 April 2021
Resolved
Logs and records must be maintained to ensure operational readiness of firefighting and life saving equipment. No records or maintenance could be verified. Established log record system with the vessel representative.
Action required: 10 - Deficiency Rectified
Due 23 April 2021
Resolved 23 April 2021
Resolution: Logs/ record system established
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 23 April 2021
Resolved
Float light for the port side life float was identified as potentially not water tight, missing a securing pin for the float light cap. Replace the float light associated with port life float
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 May 2021
Resolved 29 April 2021
Resolution: RCVD email with photo and receipt for a new float light purchased
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 23 April 2021
Resolved
The name of the vessel must be marked or painted in clearly legible letters on each life float paddle. No labeling on any of the three life float paddles (6 Paddles). Label paddles as required.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 May 2021
Resolved 28 April 2021
Resolution: Paddles Stencilled. RCVD photo evidence of such
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 23 April 2021
Resolved
The float free light must be designed to float free in case of a rapid emergency where manual deployment may not be possible. The float light associated with the center life float bracket was modified jamming the float light from floating free. Re-configure this life floats, float light to allow for float free configuration.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 May 2021
Resolved 26 April 2021
Resolution: The light bracket was modified by the O/O to allow for float free operations
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 23 April 2021
Resolved
EPIRB must be installed in a position to allow for float free operation. Currently the EPIRB is installed so low to the deck, that the cover cannot pop off and allow the EPIRB to float free. Re-configure EPIRB float free container.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 May 2021
Resolved 26 April 2021
Resolution: The EPIRB case was raised in order to allow for float free operations.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 23 April 2021
Resolved
Monthly EPIRB maintenance and check must be logged. Established record maintenance system with the O/O.
Action required: 10 - Deficiency Rectified
Due 23 April 2021
Resolved 23 April 2021
Resolution: Established log/ record system
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 23 April 2021
Resolved
Vessel first aid kit contents identified expired. Remove all expired contents from the first aid kit. Vessel representative replaces contents regularly and the required amount of contents not expired were on board.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 May 2021
Resolved 26 April 2021
Resolution: First Aid Kit contents expired were removed and replaced. RCVD phot of reciept for expired items.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 23 April 2021
Resolved
The EPIRB’s battery must be replaced prior to the date required by 47 CFR. Identified the EPIRB battery marking expired on 12/2018. Restrict operations to no more than 3 miles from shore until the EPIRB battery is replaced.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 April 2021
Resolved 26 April 2021
Resolution: New EPIRB purchased and registered.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 April 2019
Resolved
Provide a number of child size life jackets equal to at least 10% of the number of persons permitted on board.
46CFR108.71(a)
Action required: 17 - Rectify deficiencies prior to departure
Due 16 April 2019
Resolved 10 July 2019
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 16 April 2019
Resolved
Vessel did not have emergency instructions posted. 46CFR185.510
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 May 2019
Resolved 10 July 2019
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 11 April 2018
Resolved
Replace stbd CO2 bottle bracket.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 May 2018
Resolved 23 July 2018
Resolution: O/O installed new bracket
Communications › Radio Communications › VHF Radiotelephone
Issued 11 April 2018
Resolved
Program correct MMSI into VHF radio.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 May 2018
Resolved 23 July 2018
Resolution: O/O update MMSI # in DSC VHF
Communications › Radio Communications › VHF Radiotelephone
Issued 12 April 2016
Resolved
Install proper VHF-DSC radio equipment. 46 CFR 184.502 and 47 CFR 80.
Action required: 705 - Other - as specified
Due 28 April 2016
Resolved 21 April 2016
Lifesaving › Visual Distress Signals (General) › Not on Board
Issued 12 April 2016
Resolved
Provide 12 approved flares at operating station. (12 Hand red OR 6 red and 6 orange) 46 CFR 180.68 Prior to carrying passengers.
Action required: 705 - Other - as specified
Due 12 April 2016
Resolved 15 April 2016
Resolution: 12 Hand red flares provided on board.
Operations/Management › Drills/Instruction › Making Voice Radio Distress Call
Issued 12 April 2016
Resolved
Post emergency broadcast placard at operating station. 46 CFR 185.406
Action required: 705 - Other - as specified
Due 28 April 2016
Resolved 21 April 2016
Communications › Alarms/Indicators › Bilge Alarm
Issued 12 April 2016
Resolved
Prove proper operation of bilge high level alarm in forepeak. 46 CFR 182.530
Action required: 705 - Other - as specified
Due 28 April 2016
Resolved 15 April 2016
Electrical › Electrical Distribution System (service) › Wiring
Issued 12 April 2016
Resolved
Replace wire nuts on Bilge pump in lazarette with acceptable connectors. 46 CFR 183.340
Action required: 705 - Other - as specified
Due 28 April 2016
Resolved 15 April 2016
Lifesaving › Lifefloat › Paddle
Issued 12 April 2016
Resolved
Provide 2nd paddle for stbd life float (vessel has 3 LF's and 5 paddles, one more req'd) 46 CFR 160.010-8
Action required: 705 - Other - as specified
Due 28 April 2016
Resolved 15 April 2016
Lifesaving › Lifefloat › Markings
Issued 12 April 2016
Resolved
Label all paddles in lifefloats with vessel name. 46 CFR 185.604
Action required: 705 - Other - as specified
Due 28 April 2016
Resolved 15 April 2016