← All vessels
CELTIC GRACE
Passenger (Inspected) · Passenger Ship class · Built 1970s · USCG Northeast District (CGD-NE) · Other hulls named CELTIC GRACE
CELTIC GRACE is a 1970 passenger vessel (inspected). The Coast Guard has recorded 71 inspections since 1985, most recently in April 2026, along with 178 deficiencies and 2 casualty investigations between 2010 and 2022.
Records from 1985 to 2026. Most recent: inspection, 27 April 2026.
- Built
- 1970
- Last inspected
- 27 April 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 178 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 2 investigations · 2010–2022
Identity
525513
WDH8721
46547
Flag
UNITED STATES
367660850
Maury page id
psix-46547
Inspections, by type
…with no type recorded7
Years with a record
39 calendar years (1985–2026)
The 71 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)64.5 ft × 22.7 ft × 7.8 ft
Registered tonnagegross 87 / net 59
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderOUTER BANKS BOATWORKS INC · HARKER'S ISLAND, NC, UNITED STATES · built 1970
Hull materialWood
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portPORT JEFFERSON, NY
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 11 September 2025 · expires 31 October 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it87 - Regulatory (Subpart C or D), Gross Ton
59 - Regulatory (Subpart C or D), Net Ton
59 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDH8721MMSI 367660850 · active · compulsorily equipped · granted 8 April 2025, expires 11 March 2035
WDG3512MMSI 367526820 · expired · compulsorily equipped · granted 21 April 2012, cancelled 25 June 2022 · licensed under a name not among this hull’s recorded names (not shown)
WDD3424MMSI 367131180 · expired · compulsorily equipped · granted 22 July 2006, cancelled 24 September 2016 · licensed under a name not among this hull’s recorded names (not shown)
WDC9462MMSI 367102590 · expired · compulsorily equipped · granted 28 March 2006, cancelled 28 May 2016 · licensed under a name not among this hull’s recorded names (not shown)
WCQ2092MMSI not assigned · expired · voluntarily equipped · granted 22 February 1995, cancelled 30 April 2005 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 71
27 April 2026
Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8357652
17 March 2026
Drydock Exam · Internal Structural Exam · Examination of Repairs
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8327577
8 April 2025
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8106599
17 April 2024
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7896725
4 March 2024
Administrative Inspection · Drydock Exam · In-Service Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7871638
20 April 2023
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7658254
14 December 2022
Deficiency Check · Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7604401
16 October 2022
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7583423
20 April 2022
COI Inspection · DAPI Audit
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7411370
23 April 2021
DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7181181
14 December 2020
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7111749
7 July 2020
Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6966922
16 April 2019
Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6643292
7 December 2018
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6594715
2 September 2018
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6555200
23 July 2018
Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6488045
11 April 2018
Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6361749
14 December 2017
Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6317740
14 April 2017
Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6114437
19 November 2016
Type not recorded
No type recorded · Station New Haven · USCG Northeast District (CGD-NE) · Activity 6044519
12 April 2016
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 5852185
16 December 2015
Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 5783180
15 May 2014
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 4856678
16 May 2012
Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 4312873
24 August 2011
Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 4124830
5 August 2008
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3286191
1 May 2008
Hull Examination · Internal Structural Exam · Examination of Repairs
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3196004
9 May 2007
COI Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2926231
21 July 2006
Administrative Inspection · Re-Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2720460
12 April 2006
Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2622778
27 May 2005
Annual Inspection
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 2331872
8 June 2004
MARPOL Annex V Examination · Annual Inspection
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 2044712
15 April 2004
Hull Examination · Internal Structural Exam
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 2040093
2 June 2003
MARPOL Annex V Examination · Annual Inspection
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 1805612
15 April 2002
COI Inspection · MARPOL Annex V Examination
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 1604149
3 April 2002
Internal Structural Exam · Hull Examination
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 1599760
14 June 2001
Re-Inspection · MARPOL Annex V Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1431059
22 May 2000
MARPOL Annex V Examination · Re-Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1423378
27 March 2000
Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1450451
27 March 2000
Hull Examination · Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1471008
10 May 1999
Plan Review "T" Boat
Administrative · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 800443
4 March 1999
MARPOL Annex V Examination · COI Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1127950
22 January 1999
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 787020
8 May 1998
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1128810
23 March 1998
Re-Inspection · MARPOL Annex V Examination · Hull Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1411680
26 February 1997
MARPOL Annex V Examination · Re-Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1097339
31 March 1996
COI Inspection · MARPOL Annex V Examination · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1085803
27 February 1995
COI Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 853250
11 April 1994
MARPOL Annex V Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 859837
23 March 1994
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1169640
2 November 1993
Drydock Extension
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1159849
25 February 1993
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1151960
2 April 1992
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 948099
13 February 1992
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 948098
23 May 1991
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 945522
13 February 1991
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1219972
15 June 1990
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1213874
8 May 1990
Deficiency Check · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 919722
2 March 1990
Deficiency Check · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 927969
21 March 1989
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1201614
28 February 1989
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1349534
17 March 1988
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1036326
2 March 1988
COI Inspection · Hull Examination · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1340000
3 August 1987
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1336523
22 June 1987
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1313598
4 March 1987
COI Inspection · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1326955
6 February 1987
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1010424
18 March 1986
Credit Drydock
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1304560
5 March 1986
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1298127
13 March 1985
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1289493
8 March 1985
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 978002
Deficiency record · 178
05 - Radio Communications › N/A - No Subsystem › Operation/maintenance
Issued 8 April 2025
Resolved
Provide copy of FCC certs. FCC certs on board had expired.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 8 April 2025
Resolved
Provide copy of drills. Logbook was not on board the vessel at the time of the inspection.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 8 April 2025
Resolved
Forward masthead light was inop.
09 - Working and Living Conditions › 092 - Working Conditions › Heating
Issued 8 April 2025
Resolved
Service boiler tri-annually. Boiler was not serviced.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 8 April 2025
Resolved
Provide guard around Gennie.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 April 2025
Resolved
Replace life ring. Life ring was at the end of its serviceable lifespan.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 April 2025
Resolved
Provide cover for light fixture in E/R.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 April 2025
Resolved
Replace PFD signage as appropriate.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 8 April 2025
Resolved
Collision bulkhead valve was inop.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 20 April 2023
Resolved
Repair collision compartment reach-rod for bilge suction valve.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 20 April 2023
Resolved
Replace hydrostatic release for EPIRB prior to operating more than 3 miles from shore.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 23 April 2021
Resolved
Logs and records must be maintained to ensure operational readiness of firefighting and life saving equipment. No records or maintenance could be verified. Established log record system with the vessel representative.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 23 April 2021
Resolved
Float light for the port side life float was identified as potentially not water tight, missing a securing pin for the float light cap. Replace the float light associated with port life float
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 23 April 2021
Resolved
The name of the vessel must be marked or painted in clearly legible letters on each life float paddle. No labeling on any of the three life float paddles (6 Paddles). Label paddles as required.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 23 April 2021
Resolved
The float free light must be designed to float free in case of a rapid emergency where manual deployment may not be possible. The float light associated with the center life float bracket was modified jamming the float light from floating free. Re-configure this life floats, float light to allow for float free configuration.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 23 April 2021
Resolved
EPIRB must be installed in a position to allow for float free operation. Currently the EPIRB is installed so low to the deck, that the cover cannot pop off and allow the EPIRB to float free. Re-configure EPIRB float free container.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 23 April 2021
Resolved
Monthly EPIRB maintenance and check must be logged. Established record maintenance system with the O/O.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 23 April 2021
Resolved
Vessel first aid kit contents identified expired. Remove all expired contents from the first aid kit. Vessel representative replaces contents regularly and the required amount of contents not expired were on board.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 23 April 2021
Resolved
The EPIRB’s battery must be replaced prior to the date required by 47 CFR. Identified the EPIRB battery marking expired on 12/2018. Restrict operations to no more than 3 miles from shore until the EPIRB battery is replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 April 2019
Resolved
Provide a number of child size life jackets equal to at least 10% of the number of persons permitted on board.
46CFR108.71(a)
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 16 April 2019
Resolved
Vessel did not have emergency instructions posted. 46CFR185.510
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 11 April 2018
Resolved
Replace stbd CO2 bottle bracket.
Communications › Radio Communications › VHF Radiotelephone
Issued 11 April 2018
Resolved
Program correct MMSI into VHF radio.
Communications › Radio Communications › VHF Radiotelephone
Issued 12 April 2016
Resolved
Install proper VHF-DSC radio equipment. 46 CFR 184.502 and 47 CFR 80.
Lifesaving › Visual Distress Signals (General) › Not on Board
Issued 12 April 2016
Resolved
Provide 12 approved flares at operating station. (12 Hand red OR 6 red and 6 orange) 46 CFR 180.68 Prior to carrying passengers.
Operations/Management › Drills/Instruction › Making Voice Radio Distress Call
Issued 12 April 2016
Resolved
Post emergency broadcast placard at operating station. 46 CFR 185.406
Communications › Alarms/Indicators › Bilge Alarm
Issued 12 April 2016
Resolved
Prove proper operation of bilge high level alarm in forepeak. 46 CFR 182.530
Electrical › Electrical Distribution System (service) › Wiring
Issued 12 April 2016
Resolved
Replace wire nuts on Bilge pump in lazarette with acceptable connectors. 46 CFR 183.340
Lifesaving › Lifefloat › Paddle
Issued 12 April 2016
Resolved
Provide 2nd paddle for stbd life float (vessel has 3 LF's and 5 paddles, one more req'd) 46 CFR 160.010-8
Lifesaving › Lifefloat › Markings
Issued 12 April 2016
Resolved
Label all paddles in lifefloats with vessel name. 46 CFR 185.604
Construction/Loadline › Hull › Keel
Issued 21 December 2015
Resolved
Replaced wasted worm shoe PTCHE.
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 21 December 2015
Resolved
Replace both MDE cutless bearings PTCHE
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 21 December 2015
Resolved
Make proper repairs to both keel(port and stbd). Make keel coolers available for pressure test after completion of repairs.
Construction/Loadline › Hull › Keel
Issued 21 December 2015
Resolved
Remove loose concrete patches and make repairs as per repair proposal.
Engineering › Shafting/Propeller Arrangements › Stern Tube
Issued 21 December 2015
Resolved
Clean iva port stern tube in engroom/ Remove salt and trash.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 21 December 2015
Resolved
Install missing breakers in the engine room panel.
Construction/Loadline › Hull › Keel
Issued 21 December 2015
Resolved
Refasten AFT most portside keel.
Engineering › Steering Gear System › Pump
Issued 21 December 2015
Resolved
Hard wire water pump in the steering compartment.
Operations/Management › Navigation Safety › Proper Use of Navigation/Anchor Lights
Issued 15 May 2014
Resolved
Properly install STB navigation light and cover. Limited to daylight operations and fair weather.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 15 May 2014
Resolved
Repair or replace 2 life float water lights. Restricted to day light operations.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 15 May 2014
Resolved
Properly label life jacket storage in main cabin with correct number of PFD.
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 15 May 2014
Resolved
Provide emergency broadcast placard at operation station.
Engineering › Bilge Water Management System › Hose
Issued 15 May 2014
Resolved
Repair leak in lazarette bilge pump hose. Vsl has a fixed bilge system, leak is on secondary pump.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 15 May 2014
Resolved
Install blanks or covers in engine room curcuit board.
Electrical › Electrical Distribution System (service) › Wiring
Issued 15 May 2014
Resolved
Secure hanging wires in engine room.
Engineering › Fuel Oil Service System › Valve
Issued 15 May 2014
Resolved
Label emergency fuel shut off valve outside of space.
Engineering › Bilge Water Management System › Manifold
Issued 15 May 2014
Resolved
Properly label bilge manifold in engine room.
Electrical › Electric Generation Source (service) › Panelboard
Issued 15 May 2014
Resolved
Properly label generator gauges on control panel in engine room.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 15 May 2014
Resolved
Label manual pull instructions for fixed CO2 system at bottles.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 24 August 2011
Resolved
Provide retro-reflective material for life jackets as needed.
Communications › Radio Communications › EPIRB
Issued 24 August 2011
Resolved
Provide a new hydrostatic release for float free arrangement prior to sailing more than 3 miles from shore.
Lifesaving › Lifefloat › Paddle
Issued 24 August 2011
Resolved
Provide new paddles for L/F
Lifesaving › Lifefloat › Platform
Issued 24 August 2011
Resolved
Repair or replace platform in upper L/F and clean L/F
Lifesaving › Lifefloat › Float Free
Issued 24 August 2011
Resolved
Prove proper float free arrangement
Communications › Alarms/Indicators › Bilge Alarm
Issued 24 August 2011
Resolved
Prove proper operation of high water alarms in engine room and LAZZ
Engineering › Bilge Water Management System › Pump
Issued 24 August 2011
Resolved
prove proper operation of bilge pump in LAZZ
Electrical › Electrical Distribution System (service) › Wiring
Issued 24 August 2011
Resolved
Remove dead end cables in LAZ
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 24 August 2011
Resolved
properly mount/secure stbd exhaust pipe
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 24 August 2011
Resolved
renew hose clamps on exhaust pipes
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 24 August 2011
Resolved
Provide proof of servicing all fire extinguishers
Fire Fighting › Fire Main › Condition
Issued 24 August 2011
Resolved
Repair or replace hose clamp on Fire main near overboard discharge.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 24 August 2011
Resolved
replace broken outlet covers.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 24 August 2011
Resolved
properly mount vending machines to prevent tipping.
Lifesaving › Lifebuoys › Serviceable
Issued 24 August 2011
Resolved
replace L/R buoy on stbd side
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 24 August 2011
Resolved
provide a belt guard for aft generator
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 24 August 2011
Resolved
provide a belt guard for STBD MDE
Documentation › Markings/Placards › Capacity Marking
Issued 24 August 2011
Resolved
Upper deck is limited to 30 persons, post upper deck limitation
Electrical › Lighting (service) › Switch
Issued 24 August 2011
Resolved
repair light switch cover and remount fixture
Personnel › Training › Fire Fighting Basic
Issued 24 August 2011
Resolved
conduct satisfactory MOB and firefighting drills in the presence of a CG Marine Inspector.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 24 August 2011
Resolved
Provide proof of DAPI enrollment
Electrical › Lighting (service) › Lighting Fixture
Issued 5 August 2008
Resolved
replace missing screw plug on electrical box for aft port deck light on pilothouse.
Lifesaving › Hand Flares › Expired
Issued 5 August 2008
Resolved
Replace six expired hand distress signals.
Engineering › Steering Gear System › Fastener
Issued 5 August 2008
Resolved
Secure loose foundation bolts for Kainer steering gear.
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 5 August 2008
Resolved
Remark child PFD storage.
Engineering › Shafting/Propeller Arrangements › Stern Tube
Issued 1 May 2008
Resolved
Owner is having yard open stbd shaft tube and remove for exam based upon wear found & repaired for port shaft tube at the last drydocking. Examnation indicated that the shaft has been running off ctr in the shaft tube and may have worn the tube thin on the lower edge.
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 1 May 2008
Resolved
Port & Stbd strut bearing worn. Monofilament fishing line caught in shaft worked into bearing. Remove the fish line & examine bearings for wear. Replace as necessary.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 1 May 2008
Resolved
Present port shaft for examination when pulled. Owner is pulling shaft as part of the shaft tube examination & repair project.
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 1 May 2008
Resolved
This is the completion of the owner's first operating period w/ the vessel. He noted that the engines were loaded unevenly and determined that the propellers are mismatched in size & pitch. He plans to recon the props and match them during this drydocking.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 1 May 2008
Resolved
Collision bhd galvanized steel nail fasteners found failing. Bhd battens found loose. Refasten collision bhd and caulk and secure battens in place to regain watertight integrity of bhd.
Construction/Loadline › Structures › Deck Plating
Issued 1 May 2008
Resolved
Remove rotted deck planking on foredeck, examine underdeck structues and repair as necessary. Owner plans to replace rotted section of fwd deck w/ marine plywood sheathed with epoxy FRP.
Construction/Loadline › Hull › Side Shell
Issued 1 May 2008
Resolved
Stbd rubrail IWO compt #2 fractured & worn from wear against piling over prior seasons. Crop & renew.
Engineering › Bilge Water Management System › Valve
Issued 1 May 2008
Resolved
Repair reach rod & valve in forepeak for control of bilge suction.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 1 May 2008
Resolved
Close all unused wire & piping penetrations in the watertight bhds. (Note: Owner has been removing out of service wiring and piping that was replace over prior years of operation due to wear & tear of normal ops. The work progressed during winter lay-up and several of the penetrations remain to be closed.)
Construction/Loadline › Structures › Ventilators
Issued 1 May 2008
Resolved
Multiple vents thru the maindeck IWO of the covering board and leading up thru the bulwarks were found to be missing a batten to close them to the weather at the deck level on the outboard side of the bulwarks. Owner is fabricating new vent parts to correct the lack of watertight integrity within the vents. (Vessel restricted to protected waters.) Opening must be 12" or more above deck.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 9 May 2007
Resolved
Repair stern light prior to operating at night.
Electrical › Electrical Distribution System (service) › Wiring
Issued 9 May 2007
Resolved
Remove all dead end wires throughout the vessel
Communications › Public Address System › Loudspeaker
Issued 9 May 2007
Resolved
Make necessary repairs to public address system.
Communications › Alarms/Indicators › Bilge Alarm
Issued 9 May 2007
Resolved
Repair bildge high water alarm in forward compartment prior to carrying passengers.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 9 May 2007
Resolved
Properly label 12v panel in pilot house.
Lifesaving › Lifefloat › Serviceable
Issued 9 May 2007
Resolved
Rearrange lifefloats as discussed and properly label paddles and secure to lifefloats.
Lifesaving › Lifebuoys › Serviceable
Issued 9 May 2007
Resolved
Properly patch or replace port side lifering.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 9 May 2007
Resolved
Provide one new adult lifejacket, and provide new retroflective material on several jackets
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 9 May 2007
Resolved
Properly mount all portable fire extinguishers with CG approved brackets.
Electrical › Lighting (service) › Lighting Fixture
Issued 9 May 2007
Resolved
Provide light covers and guards for three lights in engineroom.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 9 May 2007
Resolved
Provide blanks for breaker panel in engine room on forward bulkhead.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 27 May 2005
Resolved
Provide valid enrollment in a drug and alcohol consurtium.
Lifesaving › Lifefloat › Float-free Link
Issued 27 May 2005
Resolved
Connect 3 weak links for LF to vsl.
Engineering › Sea-water System (primary cooling) › Piping
Issued 27 May 2005
Resolved
Repair water leak through exhaust pipe in the lazerette. Damage to inboard port piping near forward bulkhead.
Deck/Cargo › Holds/Tanks › Hatch
Issued 27 May 2005
Resolved
Permanently connect hatches to vsl.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 27 May 2005
Resolved
Update first aid kit.
Lifesaving › Lifefloat › Paddle
Issued 27 May 2005
Resolved
Replcae/ Reattach paddles to lifefloats.
Communications › Alarms/Indicators › Bilge Alarm
Issued 15 April 2002
Resolved
Prove proper operation of high level bilge alarms in all compartments. Label panels.
Personnel › Training › Search and Rescue
Issued 15 April 2002
Resolved
Conduct drills and training prior to first trip w/ passengers. Provide proof of drills/training for 3 months ending 15 Jul 02.
Lifesaving › Buoyant Apparatus
Issued 15 April 2002
Resolved
Replace wasted wood platforms on 2 of the 3 lifefloats. Vessel restricted to 1 mile from shore until corrected.
Lifesaving › Buoyant Apparatus
Issued 15 April 2002
Resolved
Renew line that holds board in 3rd lifefloat. Vessel restricted to no more than 1 nm from shore until corrected.
Lifesaving › Buoyant Apparatus
Issued 15 April 2002
Resolved
Stencil vessel name on fire ax, life float paddles and ringbuoy.
Engineering › Diesel Engine (propulsion-electric)
Issued 15 April 2002
Resolved
Renew/repair bridge RPM guage on bridge.
Communications › Radio Communications › EPIRB
Issued 15 April 2002
Resolved
Renew hydrostatic release for EPIRB. Vessel restricted to no further than 3nm from shore until complete.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 15 April 2002
Resolved
Renew aspirin & eyewash in first aid kit. Remove expired items.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 15 April 2002
Resolved
Provide tides and tidal current tables.
Communications › Radio Communications
Issued 15 April 2002
Resolved
Change radio station license to current vessel name. LEGACY COMPONENT DESC: VFH Radiotelephone
Communications › Radio Communications
Issued 15 April 2002
Resolved
Renew safety telephony certificate. Vessel restricted to no further than 1000 ft from shore until corrected. LEGACY COMPONENT DESC: VFH Radiotelephone
Engineering › Fuel Oil Service System
Issued 15 April 2002
Resolved
Restencil fuel shutoff locations.
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 15 April 2002
Resolved
Repair toilet in men's head.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 15 April 2002
Resolved
Service portable fire extinguishers.
Accommodation/Occupational Safety
Issued 14 June 2001
Resolved
PROVIDE AND POST EMERGENCY INSTRUCTIONS.
Engineering
Issued 14 June 2001
Resolved
REPAIR EXHAUST LEAK ON INBOARD MUFFLER IN STBD STEERING COMPARTMENT.
Lifesaving
Issued 14 June 2001
Resolved
REPLACE RETRO REFLECTIVE TAPE ON LIFEJACKETS.
Lifesaving
Issued 14 June 2001
Resolved
PROVIDE RETRO-REFLECTIVE TAPE FOR LIFERINGS.
Fire Fighting
Issued 10 May 1999
Resolved
CONDUCT INSTALLATION INSPECTION AND TEST OF FIXED CO2/FIRE DETECTION SYSTEM/PIPING.
Lifesaving
Issued 23 March 1998
Resolved
ALL RING BUOYS MUST BE INTERNATIONAL ORANGE.
Construction/Loadline
Issued 23 March 1998
Resolved
RESECURE REACH ROD FOR COLLISION BHD BILGE SUCTION VALVE.
Engineering
Issued 23 March 1998
Resolved
REWRAP OUTBOARD EXHAUST PIPES FOR BOTH MDE W/ LAGGING.
Lifesaving
Issued 23 March 1998
Resolved
CLEAN OIL FROM BILGES.
Engineering
Issued 23 March 1998
Resolved
RENEW HANDLE FOR STBD FUEL CONTROL VALVE AT FWD BHD OF ENGINE SPACE.
Unknown
Issued 23 March 1998
Resolved
PROVIDE A HANGER FOR SINK DRAIN PIPING STBD SIDE FWD ON OVERHEAD OF ENGINE SPACE.
Lifesaving
Issued 23 March 1998
Resolved
PROVIDE 3 BRACKETS FOR WATERLIGHTS. (BRACKETS ON TOP OF WHEELHOUSE ARE WORN OUT.)
Lifesaving
Issued 23 March 1998
Resolved
CLEAN PFDS.
Lifesaving
Issued 23 March 1998
Resolved
PROVIDE TWO PADDLES FOR LIFE FLOATS.
Lifesaving
Issued 23 March 1998
Resolved
RENEW WORN LINE HOLDING DROP NET IN STBD LIFE FLOAT.
Lifesaving
Issued 23 March 1998
Resolved
RENEW PENDANTS WHICH ARE SUN DRIED ON STBD LIFE FLOAT.
Engineering
Issued 23 March 1998
Resolved
TEST ALL MACHINERY, STEERING, PUMPS AND ALARMS WHEN VESSEL IS REFLOATED.
Electrical
Issued 23 March 1998
Resolved
SECURE WIRING HARNESS FOR THE 20 KW NORTHERN LIGHTS GEN SET SO THAT IS OUT OF THE BILGE AND NOT WHERE IT CAN BE DAMAGED BY CREW WALKING BY OR BE TRIPPED OVER.
Electrical
Issued 23 March 1998
Resolved
RESECURE PVC WIRING CONDUIT PORT SIDE IWO SWITCHBOARD.
Electrical
Issued 26 February 1997
Resolved
REPAIR WASTED SECTION OF EXHAUST PIPING ON 2-71 GMC DIESEL AND INSTALL LAGGING ON THE UNCOOLED SECTION.
Construction/Loadline
Issued 26 February 1997
Resolved
CROP OUT DETERIORATED WOOD AT STRUT BOLTS AND REPAIR. ( A WELL FITTED GRAVING BLOCK/DUTCHMAN GLUES W/ EPOXY IS ACCEPTABLE FOR REPAIR.)
Lifesaving
Issued 26 February 1997
Resolved
RENEW WORN LINES FOR DROP BASKET IN LIFE FLOATS.
Lifesaving
Issued 26 February 1997
Resolved
PROVIDE FCC EMERGENCY INSTRUCTION PLACARD AT THE BRIDGE RADION STATION.
Navigation
Issued 26 February 1997
Resolved
MOVE DECK LICHTS OR SIDELIGHTS SO THAT THEY DO NOT INTERFER W/ EACH OTHER.
Electrical
Issued 26 February 1997
Resolved
DEMONSTRATE OPERATION OF THE REPLACEMENT NORTHERN LIGHTS GENSET.
Documentation
Issued 26 February 1997
Resolved
RENEW FCC RADIOTELEPHONE SAFETY CERTIFICATE. CURRENT CERT EXPIRES 7APR97.
Electrical
Issued 26 February 1997
Resolved
PROVIDE DRIP SHIELDS ON ENGINE ROOM ELECTRICAL SWITCHBOARDS AND PANELS.
Engineering
Issued 11 April 1994
Resolved
REINSTALL & PROVE PROPER OPERATION OF ONAN GENERATOR.
Documentation
Issued 2 November 1993
Resolved
DRYDOCK VESSEL FOR EXAMINATION NOT LATER THAN 31JAN94. A (3) THREE MONTH EXTENTION OF THE DRYDOCK INTERNAL HAS BEEN GRANTED EFFECTIVE 31OCT93.
Engineering
Issued 13 February 1991
Resolved
REPLACE LEAKING SEAL ON STBD ENGINE H20 PUMP_x001C_ _x001C_ _x001C_ _x001C_
Engineering
Issued 13 February 1991
Resolved
RENEW END FITTING ON CLUTCH CONTROL CABLE FOR STBD ENG.
Lifesaving
Issued 13 February 1991
Resolved
RENEW BATTERY IN WATERLIGHT FOR LIFE FLOAT.
Engineering
Issued 13 February 1991
Resolved
REPLACE WASTED EXHAUST PIPES AND RISER._x001C_ _x001C_ _x001C_ _x001C_
Lifesaving
Issued 13 February 1991
Resolved
RENEW PENDANTS ON LIFE FLOATS AND REMARK LIFE FLOATS._x001C_ _x001C_ _x001C_ _x001C_
Fire Fighting
Issued 13 February 1991
Resolved
RENEWED BOTH FIRE HOSES._x001C_ _x001C_ _x001C_ _x001C_
Accommodation/Occupational Safety
Issued 13 February 1991
Resolved
RECAULK STEM TO SIDE PLANKING JOINT_x001C_ _x001C_ _x001C_ _x001C_
Engineering
Issued 13 February 1991
Resolved
REPLACE BROKEN STRAINER ON BILGE SUCTION IN #2 COMPT. AND CLEAN BILGE IN FWD COMPT.
Construction/Loadline
Issued 8 May 1990
Resolved
RENEWED WOOD ALKALI / ELECTROLYSIS DAMAGED SECTIONS OF WOOD IN WAY OF SHAFTTUBES.
Construction/Loadline
Issued 8 May 1990
Resolved
RECAULKED FOREDECK.
Construction/Loadline
Issued 8 May 1990
Resolved
RENEWED WORM EATEN SECTION OF STERN FRAME AT AFT END OF KEEL.
Construction/Loadline
Issued 8 May 1990
Resolved
BURNED OUT AND TREATED W/ EPOXY WORM INFESTED AREAS ALONG LOWER SECTION OF THE KEEL.
Construction/Loadline
Issued 8 May 1990
Resolved
RENEWED AFT SECTION OF DECKHOUSE OVERHEAD.
Construction/Loadline
Issued 8 May 1990
Resolved
REPAIRED WOOD ALKALI / ELECTROLYSIS DAMAGE TO AFT BHD OF MACHINERY SPACE AND NECT BHD AFT IN WAY OF CU BILGE PIPING PENETRATION & REFASTENED LOWER SECTION OF BHDS.
Navigation
Issued 2 March 1990
Resolved
REPLACE SIDE LIGHTS W/ LIGHTS ACCEPTABLE UNDER COL-REGS FOR A VESSEL OVER 20 METERS.
Unknown
Issued 2 March 1990
Resolved
CONDUCT AN UNDERWAY EXAM.
Lifesaving
Issued 2 March 1990
Resolved
RENEW WORN LIFELINES AND PENDANTS / PAINT AND REMARK LIFE FLOATS.
Lifesaving
Issued 2 March 1990
Resolved
REPLACE THREE PFD'S ( ADULT )
Lifesaving
Issued 2 March 1990
Resolved
RENEW WORN RING BUOYS.
Engineering
Issued 2 March 1990
Resolved
PROVE OPERATION OF STBD MDE AND ITS RELATED PUMPS AND CONTOLS.
Unknown
Issued 2 March 1990
Resolved
RENEW WASTED HEATER FLUE PIPE. HEATER OUT OF SERVICE UNTIL REPAIRS MADE.
Electrical
Issued 2 March 1990
Resolved
REPAIR OR REMOVE ONAN AUX GENERATOR.
Engineering
Issued 28 February 1989
Resolved
REPAIR BILGE ALARM SENSORS.
Electrical
Issued 28 February 1989
Resolved
LINE FORWARD BATTERY MOUNT GENERATOR STARTING BANK WITH LEAD OR FRP.
Fire Fighting
Issued 28 February 1989
Resolved
RECHARGE DRY CHEMICAL BCII FIRE EXTINGUISHER PRIOR TO GETTING UNDERWAY BUT 03MAR89.
Lifesaving
Issued 28 February 1989
Resolved
LABEL FIRE AXE AND BOUYANT APPARATUS PADDLES WITH VESSEL'S NAME.
Fire Fighting
Issued 2 March 1988
Resolved
HYDRO TEST BOTH B-II CO2 PORTABLE EXTINGUISHERS.
Lifesaving
Issued 2 March 1988
Resolved
PROVIDE ADDITIONAL REFLECTIVE TAPE ON THE BACK OF 24 ADULT PFD'S.
Navigation
Issued 4 March 1987
Resolved
REPOSITION NAV LIGHTS TO CONFORM WITH COLREGS
Engineering
Issued 4 March 1987
Resolved
PROVIDE OPERATION OF HIGH TEMP ALARMS ON BOTH MAIN ENGINES.
Electrical
Issued 4 March 1987
Resolved
PROVE PROPER OPERATION OF 110 VAC ON AN AUX GENERATOR.
Electrical
Issued 4 March 1987
Resolved
PROVE PROPER OPERATION OF OVERSPEED TRIPS ON 110 VAC AUX GENERATOR.
Electrical
Issued 4 March 1987
Resolved
REMOVE SMALL WIRE FROM FM RADIO FROM 12V BATTERY AND RECONNECT AFTER MAIN DISCONNECT AND PROVIDE OUVERCURRENT PROTECTION.
Lifesaving
Issued 4 March 1987
Resolved
PROVIDE ADDITIONAL REFLECTIVE MATERIAL ON THE BACK OF ALL LIFE PRESERVERS.
Casualty record · 2
25 May 2010Routine · role: Involved in a Marine Casualty · activity 3761127
16 October 2022Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 7583423
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Recorded names · 1
TRADEWINDS II (2010). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.