Records from 1983 to 1997. Most recent: inspection, 15 October 1997.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 34
15 October 1997
Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 776981
7 April 1997
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1097572
28 March 1997
Hull Examination · Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1430373
16 February 1996
Hull Examination · Re-Inspection · Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1414536
22 March 1995
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1135398
15 March 1995
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1465821
22 December 1994
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 695673
11 November 1994
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 214882
18 April 1994
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 858539
11 March 1994
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1165227
10 December 1993
Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 849749
8 November 1993
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 695672
4 November 1993
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 213164
15 March 1993
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1144872
14 January 1993
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 838657
14 January 1993
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1140494
24 March 1992
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1261032
5 February 1992
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1261630
7 May 1991
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1212928
25 March 1991
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1220357
4 March 1991
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1215950
14 March 1990
Re-Inspection · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1247813
8 March 1989
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1194399
4 November 1988
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1203951
10 June 1988
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1201734
2 March 1988
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1027516
2 November 1987
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1329572
26 March 1987
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1018279
18 November 1986
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1330625
3 March 1986
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1299904
13 November 1985
Credit Drydock
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1301317
13 March 1985
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1287721
21 March 1984
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1279669
15 March 1983
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 966293
Construction/Loadline
Issued 28 March 1997
Resolved
LOCATED 3 HULL PLANKS ON THE PORTSIDE BOW BELOW THE CHINE BOARD AND JUST AFT OF THE STEM THAT WERE SHORTER THAN ALLOWED BY COAST GUARD NVIC 7-95. PLANKS WERE RENEWED AS ORIGINAL WITH NO PLANK SHIORTER THAN 6 FRAMES OR 5 FEET.
Condition: Unknown
Due 28 March 1997
Resolved 8 April 1997
Electrical
Issued 28 March 1997
Resolved
PROVIDE A DERATING PLACARD FOR THE MAIN GENERATOR._x001C_ 46 CFR 183.350
Condition: Unknown
Due 14 April 1997
Resolved 8 April 1997
Lifesaving
Issued 28 March 1997
Resolved
PROPERLY INSTALL MACHINERY GUARDS AROUND ENGINE PULLY SYSTEMS._x001C_ 46 CFR 176.830(b).
Condition: Unknown
Due 14 April 1997
Resolved 8 April 1997
Construction/Loadline
Issued 28 March 1997
Resolved
PROVIDE A MEANS TO MAKE ALL WEATHER DECK HATCHES WATERTIGHT._x001C_ 46 CFR 171.124
Condition: Unknown
Due 14 April 1997
Resolved 8 April 1997
Electrical
Issued 16 February 1996
Resolved
PROVIDE AMP, VOLT AND FREQUENCY METER FOR GENERATOR, IAW 46CFR 183.10-5(G).
Condition: Unknown
Due 19 February 1996
Resolved 21 February 1996
Electrical
Issued 16 February 1996
Resolved
PROVIDE MANUFACTURES NAME PLATE DATA FOR GENERATOR, IAW 46 CFR 183.10-5
Condition: Unknown
Due 19 February 1996
Resolved 21 February 1996
Electrical
Issued 16 February 1996
Resolved
PROVIDE DOCUMENTATION OF GENERATOR IS 50C AMBIENT TEMP OR DERATED, IAW 46CFR 183.10-5(F)(1)&(2).
Condition: Unknown
Due 19 February 1996
Resolved 21 February 1996
Documentation
Issued 16 February 1996
Resolved
PROVIDE ON BOARD VESSEL AT ALL TIMES WHEN IN OPERATION (1)PROPER DOCUMENTATION OF VSL'S OPERATOR'S LICENSE AND (2)FCC RADIO OPERATORS PERMIT
Condition: Unknown
Due 19 February 1996
Resolved 21 February 1996
Lifesaving
Issued 16 February 1996
Resolved
RESTENCLE AND REPLACE RECTROREFLECTIVE TAPE ON 10 ALDULTS AND 01 CHILD PFD I.A.W. 46CFR 180.25-15, 180.25-25.
Condition: Unknown
Due 19 February 1996
Resolved 21 February 1996
Lifesaving
Issued 16 February 1996
Resolved
PROVIDE PORTABLE WATERTIGHT CONTAINER FOR DISTRESS SIGNALS, IAW 46CFR 180.35-10.
Condition: Unknown
Due 19 February 1996
Resolved 21 February 1996
Engineering
Issued 16 February 1996
Resolved
MARK REMOTE F/O SHUT OFF VALVE, IAW 46CFR 185.30-20.
Condition: Unknown
Due 19 February 1996
Resolved 21 February 1996
Lifesaving
Issued 16 February 1996
Resolved
RENEW BOTH LIFEFLOAT PADDLES AND STENCLE WITH VESSEL NAME.
Condition: Unknown
Due 21 February 1996
Resolved 21 February 1996
Lifesaving
Issued 16 February 1996
Resolved
RENEW RING BOUY WATER LIGHT AND PROVIDE 6' ATTACHMENT LINE.
Condition: Unknown
Due 21 February 1996
Resolved 21 February 1996
Lifesaving
Issued 16 February 1996
Resolved
PROPERLY ATTACH LIFE FLOAT SEA PAINTER TO LIFEFLOAT AND STENCLE FLOAT CAPACITY.
Condition: Unknown
Due 21 February 1996
Resolved 21 February 1996
Accommodation/Occupational Safety
Issued 16 February 1996
Resolved
RENEW FRACTURED STBD WINDSHIELD IN PILOTHOUSE.
Condition: Unknown
Due 21 February 1996
Resolved 21 February 1996
Construction/Loadline
Issued 16 February 1996
Resolved
REPAIR WATER LEAK ON HULL IN FORWARD CABIN PORT SIDE 2ND FRAME FORWARD AT BUNK.
Condition: Unknown
Due 21 February 1996
Resolved 21 February 1996
Engineering
Issued 16 February 1996
Resolved
REPAIR OIL LEAK ON STBD ENGINE AT LUBE OIL FILTER.
Condition: Unknown
Due 21 February 1996
Resolved 21 February 1996
Electrical
Issued 16 February 1996
Resolved
RENEW, REMOVE OR REPLACE BATTERY CHARGER WITH ONE THAT MEETS REQUIEMENTS OF46 CFR 183.05-20(f),
Condition: Unknown
Due 21 February 1996
Resolved 21 February 1996
Electrical
Issued 16 February 1996
Resolved
CONNECT BONDING STRAP TO BOTH STRUTS.
Condition: Unknown
Due 21 February 1996
Resolved 21 February 1996
Construction/Loadline
Issued 16 February 1996
Resolved
FOR DETAILED LIST OF NUMERIOUS HULL REPAIRS COMPLETED DURING THIS DRYDOCK PERIOD, SEE MINS CASE NUMBER MI95038298 FOR DETAILS.
Condition: Unknown
Due 19 February 1996
Resolved 21 February 1996
Electrical
Issued 16 February 1996
Resolved
PROVIDE PROPER OPERATION OF GENERATOR.
Condition: Unknown
Due 19 February 1996
Resolved 21 February 1996
Lifesaving
Issued 16 February 1996
Resolved
RENEW LINE FOR LIFE FLOAT WATERLIGHT, IAW 46CFR 180.15(d)(i)&(ii).
Condition: Unknown
Due 19 February 1996
Resolved 21 February 1996
Lifesaving
Issued 16 February 1996
Resolved
RENEW LIFEFLOAT WEAK LINK WITH ONE PROPERLY SIZED FOR A 12 PERSON LIFEFLOAT
Condition: Unknown
Due 21 February 1996
Resolved 21 February 1996
Construction/Loadline
Issued 15 March 1995
Resolved
CONDUCT REQUIRED UNDERWAY OPERATIONAL SEATRIAL TO PROVE HULL TIGHTNESS, TO BE COMPLETED TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 15 April 1995
Resolved 24 March 1995
Engineering
Issued 15 March 1995
Resolved
REPAIR STBD PROPULSION ENGINE EXHAUST SYSTEM LEAK AT THE MANIFOLD TO EXHAUST PIPING CONNECTION DUE TO LEAKING COOLING WATER/EXHAUST GASES.
Condition: Unknown
Due 15 April 1995
Resolved 24 March 1995
Construction/Loadline
Issued 11 March 1994
Resolved
DRYDOCK VSL AND MAKE NECESSARY REPAIR(S) TO SUSPECT PLANKING PORT SIDE AT CHIME IN COMPARTMENT AFT OF ROPE LOCKER
Condition: Unknown
Due 11 March 1994
Resolved 17 March 1994
Engineering
Issued 11 March 1994
Resolved
INSTALL MEANS TO CONTROL MDE'S FROM PRIMARY STEERING STATION IAW 46CFR 175.10-29
Condition: Unknown
Due 11 March 1994
Resolved 17 March 1994
Construction/Loadline
Issued 11 March 1994
Resolved
MAKE WATERTIGHT HATCHES LOCATED FON WEATHERDECK FORE AND AFT
Condition: Unknown
Due 11 March 1994
Resolved 22 March 1994
Engineering
Issued 25 March 1991
Resolved
PROVE PROPER OPERATION OF SUBMERSABLE BILGE PUMP INDICATOR LIGHTS
Condition: Unknown
Due 25 March 1991
Resolved 25 March 1991
Electrical
Issued 25 March 1991
Resolved
PROVE PROPER OPERATION OF S/S GENERATOR.
Condition: Unknown
Due 25 March 1991
Resolved 25 March 1991
Engineering
Issued 25 March 1991
Resolved
PROVIDE OPERATING HANDLE FOR REMOTE FUEL SHUTOFF VALVE.
Condition: Unknown
Due 25 March 1991
Resolved 25 March 1991
Unknown
Issued 4 March 1991
Resolved
SUBMIT DRAWING OF NEWLY INSTALLED THRU HULL FITTING FOR A/C INTAKE ON PORT SIDE. DRAWING TO INCLUDE SIZE AND TYPE OF VALVE ASSEMBLY.
Condition: Unknown
Due 4 March 1991
Resolved 4 March 1991
Construction/Loadline
Issued 26 March 1987
Resolved
PRIOR TO NEXT CREDIT DRYDOCK CONDUCT SEA TRIALS WITH A MARINE INSPECTOR ONBOARD TO OBSERVE LEAK IN WAY OF THRU HULL FITTING'S NEAR FWD END OF STBD ENGINE SLIGHTLY ABOVE WATER LINE.
Condition: Unknown
Due 26 March 1987
Resolved 26 March 1987