Records from 2016 to 2026. Most recent: inspection, 11 June 2026.
Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.
Documentation record
Registered dimensions (L × B × D)250.0 ft × 76.0 ft × 16.7 ft
Registered tonnagegross 2,656 / net 2,656
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTODD SHIPYARDS CORP · HOUSTON, TX, UNITED STATES · built 1970
Hull materialSteel
PropulsionNone
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portPORT ANGELES, WA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 19 November 2025 · expires 30 November 2026
Service, as the file records itOil Recovery
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it2656 - Regulatory (Subpart C or D), Gross Ton
2656 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page
18 inspections, each with its date, unit and type; 5 deficiencies with the resolution recorded against each; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same
counts, and they are free.
$39 a month or $299 a year, every vessel page, cancel any time.
Founding rate $19.99 a month for life, for the first 200 subscribers.
Plans
Sign in
Maury does not score, rate or grade vessels, at any price.
Inspection history · 18
11 June 2026
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8375631
7 August 2025
Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8202321
18 June 2025
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8161482
12 June 2024
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7919533
15 August 2023
Internal Structural Exam · Underwater Inspection in lieu of Drydock · Cargo Tank Internal
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7769328
12 June 2023
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7713641
16 June 2022
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7479720
22 September 2021
Administrative Inspection · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7318369
9 June 2021
MTSA Verification · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7214894
4 March 2021
Damage Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7145676
19 August 2020
Drydock Exam · Cargo Tank Internal · Internal Structural Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7030273
23 July 2020
Administrative Inspection
Administrative · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7067865
15 July 2020
Annual Inspection · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7023745
17 June 2019
MTSA Verification · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6726815
15 August 2018
Internal Structural Exam · Underwater Inspection in lieu of Drydock
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6511824
4 June 2018
MTSA Verification · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6434202
14 June 2017
Annual Inspection · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6330449
1 June 2016
Administrative Inspection · COI Inspection · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5893682
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 June 2023
Resolved
A significant ground fault was detected during the inspection of the electrical plant. This ground fault presents a hazard to personnel and or cargo operations depending on location. Isolate and correct ground fault.
Action required: 10 - Deficiency Rectified
Due 12 June 2023
Resolved 12 June 2023
Resolution: Electrician on board was able to isolate the ground fault to the engine hot start circuit. the responsible component was disconnected pending replacement.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 12 June 2023
Resolved
During the inspection of immersion suits and lifesaving equipment inspection records it was noted that the suits were 14 years old and only being pressure tested every three years. NVIC 01-08 strongly recommends and manufacturer (Viking) requires annual inspection. 46 CFR 199.190(a)
Action required: 10 - Deficiency Rectified
Due 12 June 2023
Resolved 12 June 2023
Resolution: Contacted company safety officer and CAR submitted changing the inspection intervals.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 June 2021
Resolved
Each generator prime mover must have an overspeed device that is independent of the normal operating governor and adjusted so that the speed cannot exceed the maximum rated speed by more than 15 percent. Generator was unable to reach condition to trip overspeed protective device.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 9 July 2021
Resolved 17 June 2021
Resolution: Operator sent video showing the generator overspeed trip functioning properly.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 9 June 2021
Resolved
On all tankships where the plans and arrangements will possibly permit, all passageways leading to living quarters, or places where anyone may be regularly employed, shall be provided with not less than two avenues of escape so located that if one of such avenues is not available another may be. The locality and arrangement of such additional means of escape shall be determined by the inspectors as will in their judgment best carry out the purpose for which this provision was made.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 July 2021
Resolved 14 June 2021
Resolution: Operator has corrected the emergency hatch.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 4 March 2021
Resolved
Damage sustained during a heavy storm to frames and hull in cargo tank #2 starboard side on frame 24 in way side longs 2 & 3 form the turn of the bilge. Conduct approved temporary repairs to the cracks. Make permanent repairs by cropping and renewing deflected structural members and side shell by August 2023 when ABS's intermediate hull survey is to be conducted.
46CFR31.10-25
Action required: 705 - Other - as specified
Due 31 August 2023
Resolved 22 September 2021
Resolution: ABS Class report submitted attesting to the proper repair of the sustained damage.