Records from 2016 to 2026. Most recent: inspection, 12 June 2026.
Inspection history · 18
12 June 2026
Annual Inspection · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8402975
20 January 2026
Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8298434
22 April 2025
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 8117158
11 March 2025
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8087300
6 September 2024
Deficiency Check · Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7982765
25 June 2024
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7942403
12 February 2024
Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7863476
13 March 2023
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7646213
1 March 2022
Deficiency Check · COI Inspection · Administrative Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7403747
7 February 2022
Internal Structural Exam · Drydock Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7391015
3 September 2020
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7049874
14 May 2020
Internal Structural Exam · Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6933002
6 September 2019
Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6805324
19 April 2018
DAPI Audit · COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6390896
5 April 2018
Drydock Exam · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6388157
8 February 2018
Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6352738
13 October 2016
Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6022459
24 March 2016
Drydock Exam · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5849956
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 12 June 2026
Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. Life float grab lines are deteriorated.
46 CFR 176.808 (b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 July 2026
Resolved 23 July 2026
Resolution: Replaced grab lines
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 6 September 2024
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date:(1) Charts of large enough scale to make safe navigation possible;(2) U.S. Coast Pilot or similar publication;(3) Coast Guard Light List;(4) Tide tables; and(5) Current tables, or a river current publication issued by the U.S. Army Corps of Engineers or a river authority. Vessel did not have up to date coast pilot or light list.
46 CFR 184.420(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 September 2024
Resolved 10 October 2024
Resolution: Vessel had printed copies of current coast pilot and light list onboard.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 September 2024
Resolved
Electrical equipment on a vessel must be installed and maintained to:(a) Provide services necessary for safety under normal and emergency conditions;(b) Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock;(c) Minimize accidental personnel contact with energized parts; and(d) Prevent electrical ignition of flammable vapors. Vessel had loose / missing grounding wires and several dead end wires in engine compartment.
46 CFR 183.200
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 September 2024
Resolved 10 October 2024
Resolution: Grounding wires were installed and dead-end wires removed. All sat.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 6 September 2024
Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Vessel has a loose nut on port main engine mount (inboard aft).
46 CFR 182.100
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 September 2024
Resolved 10 October 2024
Resolution: Engine mount nut was tightened. All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 September 2024
Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. Vessel's life jacket placard does not match life jackets on board.
46 CFR 185.516(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 September 2024
Resolved 10 October 2024
Resolution: Lifejacket placard was replaced with proper mfr. All sat.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 6 September 2024
Resolved
All fuel tanks must be electrically bonded to a common ground. Vessel's fuel tank was not grounded.
46 CFR 182.440(10)(b)(4)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 September 2024
Resolved 10 October 2024
Resolution: Vessel fuel tank was grounded. All sat.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 6 September 2024
Resolved
Fuel lines must be protected from mechanical injury and effectively secured against excessive movement and vibration. The return fuel line for the generator was not secured.
46 CFR 182.455(b)(3)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 September 2024
Resolved 10 October 2024
Resolution: Return fuel line was properly secured. All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 6 September 2024
Resolved
If the life float or buoyant apparatus does not have a painter attachment fitting, a means for attaching the painter must be provided by a wire or line that:(1) Encircles the body of the device. The painter line for life float was not attached around the body of the float.
46 CFR 180.137(d)(1)
Action required: 10 - Deficiency Rectified
Due 6 September 2024
Resolved 6 September 2024
Resolution: Vessel tied painter line around body of life float.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 6 September 2024
Resolved
A flexible hose may be used instead of fixed pipe for the discharge line of a submersible electric bilge pump.
The bilge discharge hose in F/O tank compartment was dry rotted.
46 CFR 182.520(f)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 September 2024
Resolved 6 September 2024
Resolution: Vessel removed rotted section of discharge hose.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 25 June 2024
Resolved
46 CFR 176.500(b)(1): Vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Vessel did not complete last annual inspection. Annual inspection is required prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 September 2024
Resolution: Vessel completed its annual Coast Guard inspection. Endorsed COI.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 2 May 2024
Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. A through hull fitting in steering compartment was replaced without an approved plan given to OCMI for approval. Haul out required to verify what was installed.
46CFR176.700(a)
Action required: 705 - Other - as specified
Resolved 15 May 2024
Resolution: A new through hull valve was installed. All sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 March 2023
Resolved
Replace plastic zip ties used to secure cords and wires with metal clamps in main hold compartment. Cable and wiring must be installed with metal supports spaced not more than 24 in apart.
46 CFR 183.340(b)(4)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 March 2023
Resolved 20 March 2023
Resolution: All zip ties have been replaced with metal clamps.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 March 2023
Resolved
Port exhaust is missing a metal clamp. Nonmettalic hose may be used for wet exhaust systems provided it is ... double clamped where practicable.
46 CFR 182.430(e)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 March 2023
Resolved 20 March 2023
Resolution: All metal clamps on the exhaust have been replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 7 March 2022
Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces: (1) A space with a through-hull fitting below the deepest load waterline, such as a lazarette. Forward and Aft hatch spaces visual alarms were inoperable.
49 CFR 182.530(a)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 March 2022
Resolution: Witnessed successful operation of visual alarms for both spaces.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 March 2022
Resolved
In systems and applications where flexible hoses are permitted to be clamped: (1) Double hose clamping is required where practicable. Fuel fill tube connection on tank only has one clamp.
46 CFR 182.410(d)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 March 2022
Resolution: Second clamp attached to hose connection.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 March 2022
Resolved
The discharge ends of fuel tank vent pipes must be fitted with removable flame screens or flame arresters. The flame screens must consist of a single screen of corrosion resistant wire of at least 30 × 30 mesh. The flame screens or flame arresters must be of such size and design as to prevent reduction in the net cross sectional area of the vent pipe and permit cleaning or renewal of the flame screens or arrester elements. Fuel vent is painted over.
46 CFR 182.450(e)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 March 2022
Resolution: Fuel vent replaced with new.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 7 March 2022
Resolved
Lifeline and pendants. The lifeline and pendants must be as furnished by the manufacturer with the approved life float or buoyant apparatus. Replacement lifelines and pendants must meet the requirements in Subpart 160.010 of this chapter. Light. The light must be a floating waterlight approved under approval series 161.010 or other standard specified by the Commandant. The floating waterlight must be attached around the body of the life float or buoyant apparatus by a 10 mm (3/8 inch) lanyard, resistant to deterioration from ultraviolet light, and at least 5.5 meters (18 feet) in length. The name of the vessel must be marked or painted in clearly legible letters on each life float paddle. Lifefloat missing pendants, lifeline, and vessel name on the paddles. Float light line was attached to the sea painter and not the body of the lifefloat.
46 CFR 185.604(g)
46 CFR 180.175(f)(1)
46 CFR 180.175(f)(4)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 March 2022
Resolution: Pendants attached, float light line attached to body of appliance, vessel name stenciled on paddles and paddles lashed to the netting.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 March 2022
Resolved
For vessels other than those covered in paragraphs (b) and (c) of this section, the name of the vessel must be marked on some clearly visible exterior part of the port and starboard bow and the stern of the vessel. The hailing port of the vessel must be marked on some clearly visible exterior part of the stern of the vessel. Vessel was not marked with the vessel name or hailing port on either bow or the stern.
46 CFR 67.123(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 18 April 2022
Resolution: Operator supplied photographs of vessel name on bow and stern of vessel.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 March 2022
Resolved
A vessel not required to have a power driven fire pump by § 181.300 must have at least three 9.5 liter (21/2 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. The words “FIRE BUCKET” must be stenciled in a contrasting color on each bucket.
46 CFR 181.610
Vessel missing 01 fire bucket.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 March 2022
Resolution: 3rd fire bucket added to the vessel.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 7 March 2022
Resolved
At each initial and subsequent inspection for certification the owner or managing operator shall be prepared to test the steering systems of the vessel and make them available for inspection to the extent necessary to determine that they are in suitable condition and fit for the service intended. Starboard steering gear mount is highly corroded.
46 CFR 176.814
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 March 2022
Resolution: Renewed steering gear mount bracket.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 1 March 2022
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Port steering gear assembly missing retaining clip on lower end of pin.
46 CFR 182.100
Action required: 705 - Other - as specified
Due 30 March 2022
Resolved 25 March 2022
Resolution: Retaining clip installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 March 2022
Resolved
Each rescue boat and ring life buoy must be marked with Type II retroreflective material approved in accordance with 46 CFR 164.018 or other standard specified by the Commandant. Each buoyant apparatus must have Type II retroreflective material meeting subpart 164.018 of this chapter on each side and end. Ring life buoy missing retro, and life float has DOT retro.
46 CFR 185.604(i)
46 CFR 160-010-4(p)
Action required: 705 - Other - as specified
Due 30 March 2022
Resolved 25 March 2022
Resolution: Operator installed SOLAS Type II retroreflective tape on lifefloat and ring buoy.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 1 March 2022
Resolved
A hatch cover must: (1) Have securing devices; and (2) Be attached to the hatch frame or coaming by hinges, captive chains, or other devices of substantial strength to prevent its loss. Aft hatch missing attachment to coaming.
46 CFR 179.360(b)(2)
Action required: 705 - Other - as specified
Due 30 March 2022
Resolved 25 March 2022
Resolution: Operator installed retaining line on hatch.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 1 March 2022
Resolved
The color of the buoyant apparatus must be vivid reddish orange as defined by FED-STD-595C, sec 13 and 14. Life float is painted wrong color.
46 CFR 160.010-4(p)
Action required: 705 - Other - as specified
Due 30 March 2022
Resolved 25 March 2022
Resolution: Operator painted life float appropriate color.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 3 September 2020
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts to make safe navigation possible, U.S. Coast Pilot [name withheld] List, Tide tables; and Current tables.
All required charts and publications were out of date. 46CFR184.420(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 September 2020
Resolved 25 March 2022
Resolution: Vessel has all up to date charts and pubs.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 3 September 2020
Resolved
The color of the buoyant apparatus must be vivid reddish orange.
Life float is painted green.
46CFR180.200(a)(2)
46CFR160.010-4(n)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 September 2020
Resolved 25 March 2022
Resolution: Life float has been painted vivid reddish orange as per regulation.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 September 2020
Resolved
Each battery must be secured to protect against shifting and free from exposure to water. Battery box was filled with water.
46CFR183.350(b)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 17 September 2020
Resolved 3 September 2020
Resolution: Battery box was drained and cover properly affixed; corrected on the spot.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 September 2020
Resolved
Electrical equipment must be permanently bonded together to a common ground by a normally non-current carrying conductor. Ground wire from the Port engine starter was not attached.
46CFR183.372(a)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 17 September 2020
Resolved 3 September 2020
Resolution: Ground wire was properly attached; corrected on the spot.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 September 2020
Resolved
Valves for removing water or impurities from diesel fuel in strainers are permitted. Valves must be provided with caps or plugs to prevent fuel leakage. Two of the three racor filter drains fitted with petcocks valves did not have caps.
46CFR182.455(b)(9)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 17 September 2020
Resolved 3 September 2020
Resolution: The two Racors have been fitted with caps; corrected on the spot.
Lifesaving › Lifefloat › Retroreflective Material
Issued 13 October 2016
Resolved
Replace/Renew retro-reflective “SOLAS”-type Tape on life float.
Due 17 October 2016
Resolved 18 October 2016
Resolution: Received email picture of correction.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 13 October 2016
Resolved
Replace/Renew deteriorated “grab lines” on life ring.
Due 17 October 2016
Resolved 18 October 2016
Resolution: Received email picture of correction.