Records from 1985 to 2023. Most recent: inspection, 30 May 2023.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 50
30 May 2023
Administrative Inspection
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7700366
21 July 2022
Administrative Inspection
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7512848
9 June 2021
Drydock Extension · COI Inspection · Internal Structural Exam
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7220459
15 July 2020
Administrative Inspection
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7007159
12 September 2019
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6808784
26 July 2018
Administrative Inspection · Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6490934
7 November 2017
DAPI Audit
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6302245
12 June 2017
Administrative Inspection · Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6187094
11 December 2015
Deficiency Check · Hull Examination · COI Inspection · Administrative Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 5779632
6 November 2015
COI Inspection · Administrative Inspection · Drydock Extension
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 5762426
5 June 2014
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4880427
7 June 2012
Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4319966
28 April 2009
Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3480811
27 June 2008
Re-Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3252397
21 May 2007
Re-Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3170821
2 March 2006
Hull Examination · COI Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 2632129
10 May 2005
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 2414129
20 May 2004
Periodic Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 2076411
7 May 2003
Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1793931
23 April 2002
Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1629173
24 April 2001
Hull Examination · COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1405211
20 April 2000
Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1406702
21 April 1999
Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1468057
21 July 1998
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 56918
28 April 1998
Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1123872
15 April 1998
COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1436070
21 April 1997
Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1383503
25 April 1996
Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1080108
6 November 1995
Hull Examination
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 886064
24 May 1995
Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1184912
19 April 1995
COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 858874
18 May 1994
Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1170556
26 April 1994
Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 858667
29 July 1993
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1156554
14 April 1993
Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 835029
31 March 1993
Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1426772
23 April 1992
Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 954933
25 March 1992
COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1258629
18 April 1991
Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1225473
27 March 1991
Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 903021
20 December 1990
Hull Examination
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1228417
28 March 1990
Administrative
Administrative · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 920294
28 March 1990
Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1230816
25 April 1989
Administrative
Administrative · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1339680
30 March 1989
COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1037399
6 April 1988
Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1033603
14 April 1987
Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1329995
1 April 1986
COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1304559
5 November 1985
Credit Drydock
Administrative · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1299099
10 April 1985
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 982609
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 12 September 2019
Resolved
Hatch covers throughout main deck do not have securing devices to prevent loss of covers. Provide means of securing covers.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 September 2019
Resolution: Received email with photo of deficiency corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 September 2019
Resolved
Ring Life Buoy (RLB) on upper deck grab line is deteriorated to the point of failure, replace line or RLB. Ensure lanyard for light is attached with a corrosion resistant clip around the body of the RLB.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 September 2019
Resolution: Received email with photo of deficiency corrected.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 12 September 2019
Resolved
Portable fire extinguisher in wheelhouse not installed with approved bracket. Mount extinguisher with appropriate bracket.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 September 2019
Resolution: Received email with photo of deficiency corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 September 2019
Resolved
Fuel shut-offs in the concessions area corroded to the point of inoperability. Ensure fuel shut-offs are maintained in a state of readiness.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 27 September 2019
Resolution: Received email with photo of deficiency corrected.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 21 August 2018
Resolved
Fire fighting drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include the following information:
(1) Date of the drill and training; and
(2) General description of the drill scenario and training topics. Vessel's crew has not been consitently logging drills.
Action required: 10 - Deficiency Rectified
Resolved 21 August 2018
Fire Fighting › Fire Pumps › Impeller
Issued 20 July 2017
Resolved
Repair pump, prove proer operation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 July 2017
Resolution: Crew member replaced fire pump impeller, tested fire pump satisfactiory.
Engineering › Fuel Oil Service System › Vent Pipe
Issued 5 June 2014
Resolved
Install proper flame screen in port fuel tank vent line.
Action required: 705 - Other - as specified
Due 5 August 2014
Resolved 17 July 2014
Resolution: Received photo of installed flame screen.
Electrical › Electrical Distribution System (service) › Cable
Issued 5 June 2014
Resolved
Found sewage pump electical motor with inpropor wiring; rewire through cable connector into motor junction box.
Action required: 705 - Other - as specified
Due 5 August 2014
Resolved 17 July 2014
Resolution: Received photo of proper connection.
Lifesaving › Rescue Boat › Carriage Requirement
Issued 20 May 2004
Resolved
Provide Rescue Boat per 46 CFR 180.210(b)(2).
Action required: 705 - Other - as specified
Due 20 June 2004
Resolved 10 May 2005
Resolution: Observed SAT operation of rescue boat
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 20 May 2004
Resolved
Conduct satisfactory man overboard drill with rescue boat.
Action required: 705 - Other - as specified
Due 20 June 2004
Resolved 11 May 2005
Resolution: Observed SATu/w MOB drill. MOB recovered in less than 2 minutes.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 23 April 2002
Resolved
DIRECTION ARROWS FOR FUEL SHUTOFF VALVE MISSING. LEGACY COMPONENT DESC: Valve
Condition: Unknown
Due 23 May 2002
Resolved 23 May 2002
Resolution: INSTALLED DIRECTION ARROW.
Lifesaving
Issued 20 April 2000
Resolved
PROVIDE 16 ADDITIONAL ADULT SIZE LIFEJACKETS FOR A TOTAL OF 152 ADULT JACKETS ONBOARD.
Condition: Unknown
Due 27 April 2000
Resolved 26 April 2000
Lifesaving
Issued 15 April 1998
Resolved
REPAIR/REPLACE 13 ADULT PFD'S; NUMBER OF ADULT PASSENGERS LIMITED TO 136 PENDING COMPLETION.
Condition: Unknown
Due 15 April 1998
Resolved 15 April 1998
Navigation
Issued 19 April 1995
Resolved
INSTALL VERTICAL FILAMENT LAMPS IN ALL RUNNING LIGHTS.
Condition: Unknown
Due 19 April 1995
Resolved 19 April 1995
Lifesaving
Issued 26 April 1994
Resolved
PROVIDE 1 ADDITIONAL ORANGE SMOKE FLARE.
Condition: Unknown
Due 26 April 1994
Resolved 26 April 1994
Construction/Loadline
Issued 26 April 1994
Resolved
INSTALL STEEL PIPING IN BILGE SYSTEM IN WAY OF FLEXIBLE HOSE.
Condition: Unknown
Due 26 April 1994
Resolved 26 April 1994
Documentation
Issued 26 April 1994
Resolved
OBTAIN A CURRENT FCC STATION LICENSE.
Condition: Unknown
Due 26 April 1994
Resolved 26 April 1994
Lifesaving
Issued 26 April 1994
Resolved
PROVIDE 7 ADDITIONAL LIFE PRESERVERS.
Condition: Unknown
Due 26 April 1994
Resolved 26 April 1994
Lifesaving
Issued 31 March 1993
Resolved
PROVIDE ONE APPROVED WATERLIGHT FOR THE RING BUOY._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 31 March 1993
Resolved 31 March 1993
Lifesaving
Issued 31 March 1993
Resolved
PROVIDE SIX ORANGE SMOKE FLARES._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 31 March 1993
Resolved 31 March 1993
Engineering
Issued 31 March 1993
Resolved
INSTALL A SHUT OFF VALVE IN THE FUEL OIL SUPPLY LINE AT THE DIESEL ENGINE._x001C__x001C_ _x001C_ _x001C_
Condition: Unknown
Due 31 March 1993
Resolved 31 March 1993
Lifesaving
Issued 31 March 1993
Resolved
PROVIDE SEVEN (7) ADULT LIFE PRESERVERS TO BRING TOTAL LIFE PRESERVERS TO 152. TOTAL NUMBER OF PERSONS ALLOWED ON BOARD WILL BE REDUCED TO 145.
Condition: Unknown
Due 31 March 1993
Resolved 31 March 1993
Lifesaving
Issued 25 March 1992
Resolved
Provide six (6) hand red flare distress signals and six (6) hand orange smoke distress signals or twelve hand combination flare and smoke distress signals per 46CFR180.35-5(a) prior to the compliance date.
Condition: Unknown
Due 25 March 1992
Resolved 25 March 1992
Navigation
Issued 25 March 1992
Resolved
Provide a copy of the Inland Navigation Rules on board per 33CFR88.05 priorto the compliance date.
Condition: Unknown
Due 25 March 1992
Resolved 25 March 1992
Construction/Loadline
Issued 25 March 1992
Resolved
Install a captive chain on the hatch cover to the forward void per 46CFR171.124(b)(2) prior to the compliance date.
Condition: Unknown
Due 25 March 1992
Resolved 25 March 1992
Lifesaving
Issued 25 March 1992
Resolved
Provide 22 adult lifejackets per 46CFR180.25-5(a) prior to compliance date.
Condition: Unknown
Due 25 March 1992
Resolved 25 March 1992
Construction/Loadline
Issued 25 March 1992
Resolved
Secure bilge piping in the stern void to the bulkhead with a bracket or brace prior to compliance date.
Condition: Unknown
Due 25 March 1992
Resolved 25 March 1992
Navigation
Issued 25 March 1992
Resolved
Replace key or locking pin in the starboard shackle to rudder arm in engineroom per 46CFR176.25-35(a) prior to compliance date.
Condition: Unknown
Due 25 March 1992
Resolved 25 March 1992
Engineering
Issued 25 March 1992
Resolved
Reattach protective guard around the exhaust manifold in the engineroom per46CFR176.25-10(b) prior to the compliance date.
Condition: Unknown
Due 25 March 1992
Resolved 25 March 1992
Lifesaving
Issued 27 March 1991
Resolved
Procure two additional adult life preservers prior to compliance date. Total persons on board restricted to 150 until life preservers onboard._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 27 March 1991
Resolved 27 March 1991
Lifesaving
Issued 27 March 1991
Resolved
Place written instructions for public announcements or post instructive placards for passenger safety orientation as per 46CFR185.25-1(d) prior to carrying passengers but not later than compiance date._x001C_ _x001C_
Condition: Unknown
Due 27 March 1991
Resolved 27 March 1991
Electrical
Issued 30 March 1989
Resolved
PROVIDE AND PROPERLY MOUNT A TRAY FOR THE ADDITIONAL 12 VOLT BATTERY IN THEMACHINERY SPACE.
Condition: Unknown
Due 30 March 1989
Resolved 30 March 1989
Engineering
Issued 30 March 1989
Resolved
PROPERLY INSTALL PERSONNEL PROTECTION FOR THE ENGINE DRY EXHAUST, EITHER GUARDS OR LAGGING SHALL BE INSTALLED.
Condition: Unknown
Due 30 March 1989
Resolved 30 March 1989
Lifesaving
Issued 30 March 1989
Resolved
PROVIDE 13 ADULT PFD'S WITH REFLECTIVE TAPE AND MARKED WITH VESSELS NAME. VESSEL IS LIMITED TO THE CARRIAGE OF 136 PASSENGER,TOTAL PERSONS ALLOWED NOT TO EXCEED 139 UNTIL THIS REQUIREMENT IS COMPLETED.
Condition: Unknown
Due 30 March 1989
Resolved 30 March 1989