MAURY USCG vessel records Sign in
← All vessels

PLOVER ARROW

PLOVER ARROW is a 1997 public freight. The Coast Guard has recorded 22 inspections since 1997, most recently in July 2019, along with 8 deficiencies and 2 operational controls.

Records from 1997 to 2019. Most recent: inspection, 17 July 2019.

Built
1997
Last inspected
17 July 2019
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9144407 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
465658
Flag
BAHAMAS, THE
—
Maury page id
psix-465658

Inspections, by type

…with no type recorded11
Years with a record 14 calendar years (1997–2019)
The 22 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it55485 - Dead Weight, Ton
36008 - Convention (Subpart B), Gross Ton
15797 - Convention (Subpart B), Net Ton
60615 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 22

17 July 2019 ISPS II Exam · Deficiency Check · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6744574
20 July 2016 ISPS III Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5946932
27 February 2012 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4250321
27 February 2012 PII Safety Exam · ISPS II Exam · Ballast Water Examination · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4251659
19 October 2010 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3869923
4 March 2009 ISPS II Exam · MARPOL Annex V Examination · Ballast Water Examination · MARPOL Annex I Examination · PII Safety Exam
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3425190
6 June 2006 Deficiency Check · PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2671875
5 June 2006 Type not recorded
No type recorded · Maritime Safety & Security Team LA/LB (91103) · Activity 2674803
4 June 2006 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2669669
10 August 2004 ISPS II Exam
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2167506
9 August 2004 MARPOL Annex V Examination · Loadline Exam · PII Safety Exam · MARPOL Annex I Examination · ILO-147 Exam
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2160540
5 April 2004 Administrative Inspection
Administrative · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2037666
5 April 2004 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2037678
6 March 2004 Damage Survey
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2019515
6 March 2004 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2020620
16 September 2003 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1906389
2 August 2002 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1656791
14 July 2001 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 291721
19 May 2000 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 278095
20 February 1999 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 425794
11 September 1998 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 420116
30 December 1997 Type not recorded
No type recorded · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 415168

Deficiency record · 8

Construction/Loadline › Structures › Door
Issued 20 July 2016 Resolved
40ac- The PSCO observed a crack in the top section of the port and starboard, F-deck superstructure door frames. ILLC 66/ 12(1)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 17 July 2019
Fire Fighting › Miscellaneous Items › Insulation (Penetration of Oil/Oil Vapors)
Issued 27 February 2012 Resolved
0710 Fire Fighting - In spaces where penetration of oil products the surface insulation shall be impervious to oil or oil vapors. The fuel oil transfer pipe on the forward starboard side lower engine room: the insulation is soaked in oil due to potential leaks. Solas 97 II-2 18.6 50(a,c)
Action required: 705 - Other - as specified
Due 30 April 2012
Resolved 29 February 2012
Operations/Management › Cargo Transfer/Lightering › Vessel Transfer Procedures on Hand
Issued 9 August 2004 Resolved
No transfer procedures onboard. Provide acceptable procedures prior to bunkering in US waters to the satisfaction of USCG.
Condition: Unknown
Action required: 703 - Prior to bunkering operations
Due 10 August 2004
Resolved 6 June 2006
Resolution: transfer procedures are onboard
Operations/Management › Mandatory Ship Reporting Systems › Entry Report
Issued 5 April 2004 Resolved
Vessel failed to report into the WHALESOUTH Mandatory Ship Reporting System prior to entering the Port of Brunswick, Ga.
Due 5 April 2004
Resolved 5 April 2004
Resolution: Vessel departed port
Construction/Loadline › Hull
Issued 6 March 2004 Resolved
Vessel grounded and hull integrity may have been compromised. Class to attest to hull integrity and seaworhtiness prior to departure of Gulfport Anchorage. LEGACY COMPONENT DESC: Hull Plating
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 March 2004
Resolution: Class Survey Report (Damage Survey) received. Ths ship sis not sustain any damages affecting class or flag requirements. No conditions of class were issued.
Electrical
Issued 30 December 1997 Resolved
PROVIDE/PLACE NONCONDUCTING (DIELECTRIC) MAT/FLOOR TILES/NONE METALIC GRATEIN ENGINE CONTROL ROOM AT LEAST IN FRONT OF HIGH VOLTAGE MAIN SWITCHBOARD, OR PROVIDE EVIDENCE EXISTING DECK COVERINGS ARE SUFFICENTLY NONECONDUCTING AS PER SOLAS CHAP II-1, REGULATION 45.2
Condition: Unknown
Due 30 January 1998
Resolved 23 April 1998
Fire Fighting
Issued 30 December 1997 Resolved
PROVIDE/PLACE SPANNER WRENCHES AT EACH FIRE & HOSE STATIONS OR HAVE FLAG STATE ADMINISTRATION CERTIFY THAT SPANNER WRENCH/TOOLS ARE NOT NECCESSARY AS PER SOLAS CHAP II-2, PART A REGULATION 4.7.1
Condition: Unknown
Due 11 September 1998
Resolved 22 September 1998
Documentation
Issued 30 December 1997 Resolved
BILGE HOLDING TANK NOT LISTED ON IOPP CERT AS WASTE OIL HOLDING TANK. CREWCONFIRMS USE OF THE TANK AS BEING USED TO HOLD BILGE OILY WATER, BUT PIPINGALSO ALLOWS FOR TRANSFERS BETWEEN OTHER WASTE OIL TANKS. CLASS (DNV) TO CORRECT/VERIFY CORRECT IOPP FORM A 3.1 AS PER MARPOL ANNEX 1 REGULATION 17.
Condition: Unknown
Due 22 February 1999
Resolved 22 February 1999

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.