← All vessels
PLOVER ARROW
PLOVER ARROW is a 1997 public freight. The Coast Guard has recorded 22 inspections since 1997, most recently in July 2019, along with 8 deficiencies and 2 operational controls.
Records from 1997 to 2019. Most recent: inspection, 17 July 2019.
- Built
- 1997
- Last inspected
- 17 July 2019
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 8 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9144407 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
C6OT4
465658
Flag
BAHAMAS, THE
—
Maury page id
psix-465658
Inspections, by type
…with no type recorded11
Years with a record
14 calendar years (1997–2019)
The 22 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it55485 - Dead Weight, Ton
36008 - Convention (Subpart B), Gross Ton
15797 - Convention (Subpart B), Net Ton
60615 - Displacement, Ton
36008 - Convention (Subpart B), Gross Ton
15797 - Convention (Subpart B), Net Ton
60615 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 22
17 July 2019
ISPS II Exam · Deficiency Check · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6744574
20 July 2016
ISPS III Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5946932
27 February 2012
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4250321
27 February 2012
PII Safety Exam · ISPS II Exam · Ballast Water Examination · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4251659
19 October 2010
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3869923
4 March 2009
ISPS II Exam · MARPOL Annex V Examination · Ballast Water Examination · MARPOL Annex I Examination · PII Safety Exam
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3425190
6 June 2006
Deficiency Check · PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2671875
5 June 2006
Type not recorded
No type recorded · Maritime Safety & Security Team LA/LB (91103) · Activity 2674803
4 June 2006
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2669669
10 August 2004
ISPS II Exam
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2167506
9 August 2004
MARPOL Annex V Examination · Loadline Exam · PII Safety Exam · MARPOL Annex I Examination · ILO-147 Exam
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2160540
5 April 2004
Administrative Inspection
Administrative · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2037666
5 April 2004
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2037678
6 March 2004
Damage Survey
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2019515
6 March 2004
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2020620
16 September 2003
Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1906389
2 August 2002
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1656791
14 July 2001
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 291721
19 May 2000
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 278095
20 February 1999
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 425794
11 September 1998
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 420116
30 December 1997
Type not recorded
No type recorded · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 415168
Deficiency record · 8
Construction/Loadline › Structures › Door
Issued 20 July 2016
Resolved
40ac- The PSCO observed a crack in the top section of the port and starboard, F-deck superstructure door frames. ILLC 66/ 12(1)
Fire Fighting › Miscellaneous Items › Insulation (Penetration of Oil/Oil Vapors)
Issued 27 February 2012
Resolved
0710 Fire Fighting - In spaces where penetration of oil products the surface insulation shall be impervious to oil or oil vapors. The fuel oil transfer pipe on the forward starboard side lower engine room: the insulation is soaked in oil due to potential leaks. Solas 97 II-2 18.6 50(a,c)
Operations/Management › Cargo Transfer/Lightering › Vessel Transfer Procedures on Hand
Issued 9 August 2004
Resolved
No transfer procedures onboard. Provide acceptable procedures prior to bunkering in US waters to the satisfaction of USCG.
Operations/Management › Mandatory Ship Reporting Systems › Entry Report
Issued 5 April 2004
Resolved
Vessel failed to report into the WHALESOUTH Mandatory Ship Reporting System prior to entering the Port of Brunswick, Ga.
Construction/Loadline › Hull
Issued 6 March 2004
Resolved
Vessel grounded and hull integrity may have been compromised. Class to attest to hull integrity and seaworhtiness prior to departure of Gulfport Anchorage. LEGACY COMPONENT DESC: Hull Plating
Electrical
Issued 30 December 1997
Resolved
PROVIDE/PLACE NONCONDUCTING (DIELECTRIC) MAT/FLOOR TILES/NONE METALIC GRATEIN ENGINE CONTROL ROOM AT LEAST IN FRONT OF HIGH VOLTAGE MAIN SWITCHBOARD, OR PROVIDE EVIDENCE EXISTING DECK COVERINGS ARE SUFFICENTLY NONECONDUCTING AS PER SOLAS CHAP II-1, REGULATION 45.2
Fire Fighting
Issued 30 December 1997
Resolved
PROVIDE/PLACE SPANNER WRENCHES AT EACH FIRE & HOSE STATIONS OR HAVE FLAG STATE ADMINISTRATION CERTIFY THAT SPANNER WRENCH/TOOLS ARE NOT NECCESSARY AS PER SOLAS CHAP II-2, PART A REGULATION 4.7.1
Documentation
Issued 30 December 1997
Resolved
BILGE HOLDING TANK NOT LISTED ON IOPP CERT AS WASTE OIL HOLDING TANK. CREWCONFIRMS USE OF THE TANK AS BEING USED TO HOLD BILGE OILY WATER, BUT PIPINGALSO ALLOWS FOR TRANSFERS BETWEEN OTHER WASTE OIL TANKS. CLASS (DNV) TO CORRECT/VERIFY CORRECT IOPP FORM A 3.1 AS PER MARPOL ANNEX 1 REGULATION 17.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.