Records from 1998 to 2017. Most recent: inspection, 27 February 2017.
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 25 January 2017
No resolution recorded
Provide updated Station Bill to reflect special duties and duty stations of each crew member. 46 CFR 122.514
Action required: 701 - Prior to carriage of passengers/cargo
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 25 January 2017
No resolution recorded
Make available all paperwork and records for the vessel’s Drug and Alcohol Program. 46 CFR 16
Action required: 701 - Prior to carriage of passengers/cargo
Personnel › Certificates/Documents/Licenses › TWIC
Issued 25 January 2017
No resolution recorded
Make available for inspection the TWIC card of all vessel personnel responsible for security duties as outlined in vessel VSP. 33 CFR 104.220
Action required: 701 - Prior to carriage of passengers/cargo
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 25 January 2017
No resolution recorded
Make available for inspection all charts and nautical publications for the area of vessel’s intended voyage to as required by 46 CFR 121.420
Action required: 701 - Prior to carriage of passengers/cargo
Construction/Loadline › Structures › Door
Issued 25 January 2017
No resolution recorded
Prove proper operation and condition of all fire doors within the vessel. 46 CFR 116.435
Action required: 701 - Prior to carriage of passengers/cargo
Construction/Loadline › Structures › Door
Issued 25 January 2017
No resolution recorded
Prove proper operation and condition of all watertight weathertight doors or hatches within the vessel. 46 CFR 116.1160
Action required: 701 - Prior to carriage of passengers/cargo
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 25 January 2017
No resolution recorded
Provide at least one ring life buoy with a lifeline of the type specified in 46 CFR 117.70.
Action required: 701 - Prior to carriage of passengers/cargo
Fire Fighting › Firemans Outfit › Axe
Issued 25 January 2017
No resolution recorded
Provide a fire axe in or adjacent to the primary operating station. 46 CFR 118.600
Action required: 701 - Prior to carriage of passengers/cargo
Operations/Management › Vessel Activity › Underway
Issued 25 January 2017
No resolution recorded
Provide means of meeting the passenger count communication requirement required by 46 CFR 122.504. 46 CFR 122.504
Action required: 701 - Prior to carriage of passengers/cargo
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 25 January 2017
No resolution recorded
Provide updated emergency evacuation plan and fire control plan to reflect vessel’s configuration. 46 CFR 116.520/530
Action required: 701 - Prior to carriage of passengers/cargo
Fire Fighting › Ventilation Systems › Operating Controls
Issued 25 January 2017
No resolution recorded
Provide means of shutting down power ventilation system from the pilot house. 46 CFR 116.600
Action required: 701 - Prior to carriage of passengers/cargo
Engineering › Fuel Oil Service System › Piping
Issued 25 January 2017
No resolution recorded
Make permanent repairs to starboard generator fuel supply piping
Action required: 701 - Prior to carriage of passengers/cargo
Engineering › Sea-water System (primary cooling) › Piping
Issued 25 January 2017
No resolution recorded
Make permanent repairs to starboard a/c unit's seawater piping
Action required: 701 - Prior to carriage of passengers/cargo
Deck/Cargo › Ballast › Vents
Issued 25 January 2017
No resolution recorded
Make permanent repairs to all wasted ballast tank vents
Action required: 701 - Prior to carriage of passengers/cargo
Construction/Loadline › Penetrations › Weld
Issued 25 January 2017
No resolution recorded
Make permanent repairs to wasted deck drain piping and side shell connections
Action required: 701 - Prior to carriage of passengers/cargo
Electrical › Lighting (emergency) › Lighting Fixture
Issued 25 January 2017
No resolution recorded
Prove proper operation of emergency lighting
Action required: 701 - Prior to carriage of passengers/cargo
Documentation › Certificates/Documents › Certificate of Inspection
Issued 25 January 2017
Resolved
Conduct drydock and internal structual exams for credit
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 February 2017
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 25 January 2017
No resolution recorded
Remove electric blowers from port and starboard sewage tank vents
Action required: 701 - Prior to carriage of passengers/cargo
Engineering › Fuel Oil Service System › Suction Strainer
Issued 25 January 2017
No resolution recorded
Install marine grade fuel strainer for bow thruster
Action required: 701 - Prior to carriage of passengers/cargo
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 25 January 2017
No resolution recorded
Install guard on bow thruster shaft
Action required: 701 - Prior to carriage of passengers/cargo
Fire Fighting › Ventilation Systems › Ducts
Issued 25 January 2017
No resolution recorded
Make permanent repairs to all wasted ventilation ducts.
Action required: 701 - Prior to carriage of passengers/cargo
Stability › Weathertight Integrity › General
Issued 25 January 2017
No resolution recorded
Make repairs to all wasted window frames through out vessel
Action required: 701 - Prior to carriage of passengers/cargo
Fire Fighting › Structural Fire Protection - General › Deckhouse Construction
Issued 25 January 2017
No resolution recorded
Repair/Renew all wasted fire screen doors and door frames
Action required: 701 - Prior to carriage of passengers/cargo
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 25 January 2017
No resolution recorded
Make permanent repairs to starboard propulsion engine's seawater overboard pipe flange at exhaust connection
Action required: 701 - Prior to carriage of passengers/cargo
Stability › Watertight Integrity › General
Issued 25 January 2017
No resolution recorded
Crop and renew all wasted deck in CO2 room
Action required: 701 - Prior to carriage of passengers/cargo
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 25 January 2017
No resolution recorded
Crop and renew wasted bulkhead that seperates galley and port engine compartment
Action required: 701 - Prior to carriage of passengers/cargo
Lifesaving › Launching Appliances › Davit
Issued 25 January 2017
No resolution recorded
Renew rescue boat davit
Action required: 701 - Prior to carriage of passengers/cargo
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 25 January 2017
No resolution recorded
Remove latch from PFD storage boxes to prevent boxes from being locked
Action required: 701 - Prior to carriage of passengers/cargo
Operations/Management › Drills/Instruction › Fire
Issued 25 January 2017
No resolution recorded
Conduct man overboard, security and fire drills
Action required: 701 - Prior to carriage of passengers/cargo
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 25 January 2017
No resolution recorded
Have fixed extinguishing systems serviced and time delays tested by certified technician in the presence of attending marine inspector
Action required: 701 - Prior to carriage of passengers/cargo
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 25 January 2017
No resolution recorded
Make repairs to inoperable fire dampers
Action required: 701 - Prior to carriage of passengers/cargo
Engineering › Steering Gear System › Actuator
Issued 25 January 2017
No resolution recorded
Overhaul/renew steering system
Action required: 701 - Prior to carriage of passengers/cargo
Engineering › Bilge Water Management System › Not Operational
Issued 25 January 2017
No resolution recorded
Prove proper operation of bilge system for the following spaces: both forepeaks, void 4 aft stbd side, steering space stbd side and void 2 port side. 46 CFR 119.510
Action required: 701 - Prior to carriage of passengers/cargo
Documentation › Logs/Records › Operational Procedures for Engines or Equipment
Issued 25 January 2017
No resolution recorded
Provide approved Design Verification and Periodic Safety test procedures for propulsion engines
Action required: 701 - Prior to carriage of passengers/cargo
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 25 January 2017
No resolution recorded
Make repair (weld broken at deck connection) to ladder leading into void 4 stbd side. 46 CFR 116.100
Action required: 701 - Prior to carriage of passengers/cargo
Engineering › Bilge Water Management System › Pump
Issued 25 January 2017
No resolution recorded
Prove proper operation of second power-driven bilge pump in port engine room space. 46 CFR 119.520
Action required: 701 - Prior to carriage of passengers/cargo
Engineering › Bilge Water Management System › Piping
Issued 25 January 2017
No resolution recorded
Remove nonmetallic (PVC) piping from installed bilge system
Action required: 701 - Prior to carriage of passengers/cargo
Construction/Loadline › Hull › Side Shell
Issued 1 August 2016
Resolved
Prior to carrying passengers, complete repairs to hull damage incurred during docking.
Action required: 705 - Other - as specified
Resolved 29 August 2016
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 25 January 2016
Resolved
Air handler rooms on decks 1 and 2 must be insulated with approved type insulation in accordance with fire control plan.
Action required: 705 - Other - as specified
Due 24 February 2016
Resolved 26 February 2016
Resolution: Rooms have been insulated.
Fire Fighting › Miscellaneous Items › Paint/Flammable Liquid Lockers
Issued 25 January 2016
Resolved
Remove all combustable materials from air handler room.
Action required: 705 - Other - as specified
Due 1 February 2016
Resolved 27 January 2016
Resolution: All flammables and combustables have been removed.
Engineering › Steering Gear System › Ram Seal
Issued 25 January 2016
Resolved
Repair oil leak on port rudder ram.
Due 1 February 2016
Resolved 27 January 2016
Resolution: Leak on steering actuator has been repaired.
Engineering › Steering Gear System › Bracket/Clamp
Issued 25 January 2016
Resolved
Repair cracked welds on rudder supports, port rudder.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 January 2016
Resolution: Cracks on rudder supports have been repaired by grinding and rewelding.
Engineering › Fuel Oil Service System › Filter
Issued 25 January 2016
Resolved
Repair fuel leak on the fuel filter housing for both the port and stbd main engines.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 January 2016
Resolution: Fuel leak has been repaired
Fire Fighting › Grease Extraction Hood › General
Issued 25 January 2016
Resolved
Clean range hoods and grease traps.
Due 1 February 2016
Resolved 27 January 2016
Resolution: Grease traps and range hoods have been cleaned.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 25 January 2016
Resolved
Properly secure CO2 extinguishers (2) in port engine room entrance.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 January 2016
Resolution: Fire extinguisher has been properly secured.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 25 January 2016
Resolved
prove proper operation of emergency light in port generator room.
Due 25 February 2016
Resolved 27 January 2016
Resolution: Proved proper operation of emergency light in port generator room.
Stability › Watertight Integrity › General
Issued 25 January 2016
Resolved
Prove proper operation of all deck hatches securing device.
Due 25 February 2016
Resolved 26 February 2016
Resolution: Proved proper operation of all deck hatch securing devices.
Fire Fighting › Fixed Fire Detection System › Annual Inspection
Issued 25 January 2016
Resolved
Prove proper operation of fixed fire detection system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 January 2016
Resolution: Proved proper operation of fixed fire detection system. Had system serviced while CGMI onboard.
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 25 January 2016
Resolved
Remove all flamables and combustables from electrical room.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 January 2016
Resolution: Removed all flamables and combustables from the electrical room.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 25 January 2016
Resolved
Prove proper operation af all fire screen doors.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 January 2016
Resolution: Proved proper operation of all fire screen doors.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 25 January 2016
Resolved
Re-secure toolbox being held up by nylon strap.
Due 25 February 2016
Resolved 27 January 2016
Resolution: Properly secured toolbox and removed temporary strap.
Electrical › Lighting (service) › Lighting Fixture
Issued 25 January 2016
Resolved
Repair broken light fixture on aft deck.
Due 25 February 2016
Resolved 27 January 2016
Resolution: Replaced broken fixture on aft deck.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 25 January 2016
Resolved
Secure hanging junction box on aft bulkhead in STBD engine room.
Due 25 February 2016
Resolved 27 January 2016
Resolution: Re-mounted junction box.
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 25 January 2016
Resolved
Re-install loose lagging on STBD MDE.
Due 25 February 2016
Resolved 27 January 2016
Resolution: Properly installed lagging.
Electrical › Electric Supply System (service) › Cable
Issued 25 January 2016
Resolved
Properly secure battery cable between battery banks.
Due 25 February 2016
Resolved 27 January 2016
Resolution: Properly secured battery cable.
Electrical › Electrical Distribution System (service) › Wiring
Issued 25 January 2016
Resolved
Remove all solid core wiring from vessel, noted in entrance to port engine room.
Due 25 February 2016
Resolved 27 January 2016
Resolution: Removed solid core wiring in port engine room entrance.
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 25 January 2016
Resolved
Repair wasted/holes steel bulkhead between mechanical room and co2 room.
Due 25 February 2016
Resolved 27 January 2016
Resolution: Installed new steel plate insert where wasted bulkhead was.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 25 January 2016
Resolved
Repair broken emergency light in STBD generator room.
Due 25 February 2016
Resolved 27 January 2016
Resolution: Proved proper operation of emergency light.
Engineering › Sea-water System (primary cooling) › Piping
Issued 25 January 2016
Resolved
Permanetly repair wasted/holes raw water piping for number 1 generator and chiller system, STBD side.
Due 25 February 2016
Resolved 26 February 2016
Resolution: Perminently repaired wasted piping.
Construction/Loadline › Structures › Door
Issued 25 January 2016
Resolved
Install missing handle on door under STBD staircase. (slot-room)
Due 25 February 2016
Resolved 26 February 2016
Resolution: Installed door handle.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 25 January 2016
Resolved
Post updated/accurate fire and safety plan throughout ship.
Action required: 705 - Other - as specified
Resolved 1 February 2016
Operations/Management › Casualty Reporting/Post-Casualty Actions › Notice of Marine Casualty
Issued 6 August 2015
Resolved
Submit drawings as per 46CFR 115.700 and prove proper operation of port and starboard main diesel engines in the presence of marine inspector prior to departing the Port of Jacksonville. (Vessel will be required to be U/W for endurance run not less than 2 hours).
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 21 October 2015
Resolved 21 October 2015
Resolution: Conducted ea Trails
Engineering › Diesel Engine (propulsion-reduction gear) › Block
Issued 23 July 2015
Resolved
Provide a technician's report identifying the source of noise observed in port main engine and detailing all necessary repairs. Once repairs are complete, demonstrate satisfactory operation to attending USCG Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 July 2015
Resolved 27 July 2015
Resolution: Vessel derparted for Jacksonville under tug assist for re-power. [name withheld] to monitor.
Engineering › Diesel Engine (propulsion-reduction gear) › Piston
Issued 3 May 2014
Resolved
Prove proper operation of STBD engine prior to carrying passengers.
Action required: 705 - Other - as specified
Resolved 23 May 2014
Resolution: Proved proper operation of engine.
Communications › Alarms/Indicators › Bilge Alarm
Issued 10 March 2014
Resolved
Prove proper operation of bilge alarms
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 March 2014
Resolution: Proved proper operation of bilge alarms.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 10 March 2014
Resolved
Provide original copy of COI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 March 2014
Resolution: Provided COI.
Navigation › Piloting/Steering › Magnetic Compass
Issued 10 March 2014
Resolved
Provide light for nightime operations. Restricted to daytime operations only until repaired or replaced.
Due 31 March 2014
Resolved 11 March 2014
Resolution: Provided light for compass.
Fire Fighting › Means of Escape › Doorways
Issued 1 November 2012
Resolved
Ensure fire doors located in both generator rooms have proper closing mechanisms.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 November 2012
Resolution: Fire doors located in both generator rooms have proper closing mechanisms.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 1 November 2012
Resolved
Vessel missing appropriate number of portable lights.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 November 2012
Resolution: Vessel has appropriate number of portable lights.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 1 November 2012
Resolved
Ensure low-risk accommodation area located in deck#3 has MSC approval.
Due 15 January 2013
Resolved 15 March 2013
Resolution: MSC approved deck covering for area.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 31 October 2012
Resolved
Vessel missing fixed fire extinguisher servicing certificates.
Action required: 705 - Other - as specified
Resolved 1 November 2012
Resolution: Vessel provided fixed fire extinguisher servicing certificates. (Service conducted 10SEP2012).
Lifesaving › Visual Distress Signals (General) › Storage
Issued 3 October 2012
Resolved
Vessel missing properly marked watertight container for distress signals.
Action required: 705 - Other - as specified
Resolved 31 October 2012
Resolution: Vessel maintains a properly marked watertight container for distress signals.
Communications › Radio Communications › EPIRB
Issued 3 October 2012
Resolved
EPRIB hydrostatic release unit expired.
Action required: 705 - Other - as specified
Resolved 31 October 2012
Resolution: EPRIB hydrostatic release unit with expiration date of OCT2014 on vessel.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 3 October 2012
Resolved
Vessel missing 02 alcohol testing kits.
Action required: 705 - Other - as specified
Resolved 31 October 2012
Resolution: Vessel has over 10 alcohol testing kits.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 3 October 2012
Resolved
No supervisors onboard vessel have required 1 hour EAP training.
Action required: 705 - Other - as specified
Resolved 31 October 2012
Resolution: Both Captains onboard vessel have required 1 hour EAP training.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 3 October 2012
Resolved
03 first aid kits with expired components.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 31 October 2012
Resolution: Vessel has 03 first aid kits with current components.
Construction/Loadline › Structures › Manhole
Issued 22 August 2008
Resolved
Make accessible for internal examination of the port fwd void forward of the port bow thruster room.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 August 2008
Resolution: Received documentary proof from the master that satisfying the requirement.
Lifesaving › Launching Appliances › Davit
Issued 8 April 2008
Resolved
Crop and Renew wasted rescue boat davit head, including replacement of limit switch and locking pin.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 April 2008
Resolved 16 April 2008
Resolution: Sited repair tested davit when running drills
Lifesaving › Launching Appliances › Davit
Issued 8 April 2008
Resolved
Properly install a releasing mechanism on the rescue boat davit hook, including one for hte bow and stern release.
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 April 2008
Resolved 16 April 2008
Resolution: Sited and tested when drills conducted
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 8 April 2008
Resolved
Conduct abandon and man overboard drill for crewmembers and demonstrate a satisfactory drill in the presence of the attending CG inspector.
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 April 2008
Resolved 16 April 2008
Resolution: Conducted drills all found sat
Electrical › Lighting (emergency) › Lighting Fixture
Issued 7 April 2008
Resolved
Properly repair emergency light in port rudder room.
Action required: 705 - Other - as specified
Due 7 April 2008
Resolved 7 April 2008
Resolution: Lights are repaired.
Construction/Loadline › Structures › Trunk
Issued 7 April 2008
Resolved
Crop and Renew wasted port generator exhaust comming port side shell plating.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 May 2008
Resolved 16 April 2008
Resolution: Sited Side shell plate
Engineering › Bilge Water Management System › Piping
Issued 7 April 2008
Resolved
Remove rubber hose installed in the stbd main engineroom bilge suction pipe. Install the correct piping.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 May 2008
Resolved 16 April 2008
Resolution: Sited Piping
Electrical › Electric Supply System (service) › Battery Installation
Issued 7 April 2008
Resolved
Remove excessive water from the starboard engineroom (inboard) battery box.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 May 2008
Resolved 16 April 2008
Resolution: Sited battery Box clear of water
Electrical › Electrical Distribution System (service) › Cable
Issued 7 April 2008
Resolved
Remove dead end electrical cable in starboard engine room.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 7 May 2008
Resolved 16 April 2008
Resolution: Cable connected to MDE shut down
Electrical › Electrical Distribution System (service) › Conductor
Issued 7 April 2008
Resolved
Clean galley oven electrical components and re-install electrical junction cover.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 May 2008
Resolved 16 April 2008
Resolution: Cleared
Electrical › Lighting (emergency) › Lighting Fixture
Issued 7 April 2008
Resolved
Service all emergency battle lanterns through out the vessel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 May 2008
Resolved 16 April 2008
Resolution: Spot checked various lights
Lifesaving › Lifefloat › Serviceable
Issued 7 April 2008
Resolved
Two lifefloats are dry rotted, have cracks, and holes. Paint seal holes and repair, or replace with new lifefloats.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 May 2008
Resolved 16 April 2008
Resolution: sited two new lifefloats
Engineering › Fuel Oil Service System › Valve
Issued 7 April 2008
Resolved
Fuel leak on bow thruster supply valve. Renew valve. Usage of the bow thruster is prohibited until leak is repaired.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 April 2008
Resolved 8 April 2008
Resolution: Installed new valved. All Sat.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 7 April 2008
Resolved
Replace on float light on lifefloat, third light form stbd side on top of pilot house. Housing is cracked open.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 May 2008
Resolved 8 April 2008
Resolution: New float light installed. All Sat.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 7 April 2008
Resolved
Galley freezer, evaporator unit and junction box are loose, reattach both to the bulkhead.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 May 2008
Resolved 8 April 2008
Resolution: Both items properly reattached. All Sat.
Engineering › Bilge Water Management System › Piping
Issued 7 April 2008
Resolved
Bilge system has unauthorized suction hoses and isolation valves installed in each space. Remove valves and hoses, and make systme to operate from manifold as required by CFR.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 May 2008
Resolved 16 April 2008
Resolution: Sited proper piping for system
Electrical › Electrical Distribution System (service) › Switch
Issued 7 April 2008
Resolved
#5 Ballast pump controller in port engine room, box is loose. Reattach to bracket.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 May 2008
Resolved 16 April 2008
Resolution: Sited box secured to bulkhead
Electrical › Electrical Distribution System (service) › Wiring
Issued 7 April 2008
Resolved
Properly route the elecrical supply cable for the A/C pump motor, port generator room.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 May 2008
Resolved 16 April 2008
Resolution: Sited cable
Communications › Alarms/Indicators › Bilge Alarm
Issued 7 April 2008
Resolved
Properly mon the bilge high level alarm float in port generator room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 May 2008
Resolved 16 April 2008
Resolution: Sited bilge alarm
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 26 March 2008
Resolved
Locate, isolate and repair dead ground for the gaming electrical system.
Action required: 705 - Other - as specified
Due 23 May 2008
Resolved 16 July 2008
Resolution: Ground repaired.
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 26 March 2008
Resolved
Repair main distribution amp meter.
Action required: 705 - Other - as specified
Due 23 May 2008
Resolved 16 July 2008
Resolution: Amp meter replace and tested satisfactory.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 26 March 2008
Resolved
Install blank in the G1 panel in the cant room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 April 2008
Resolved 16 April 2008
Resolution: Sited Blanks 2 each
Fire Fighting › Ventilation Systems › Ducts
Issued 26 March 2008
Resolved
Properly label fire dampers IAW the fire safety plan
Action required: 705 - Other - as specified
Due 7 April 2008
Resolved 16 April 2008
Resolution: Sited Label as per Fire Plan
Construction/Loadline › Hull › Hull Plating
Issued 22 February 2008
Resolved
Properly weld insert port side aft, upper most corner in port rudder room.
Action required: 705 - Other - as specified
Due 22 March 2008
Resolved 26 March 2008
Resolution: Insert is welded.
Fire Fighting › Means of Escape › Stairways
Issued 22 February 2008
Resolved
Repair broken ladder weld on lower section, port rudder room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 April 2008
Resolved 7 April 2008
Resolution: Bottom of ladder repaired with bolted section of metal plate. All Sat.
Stability › Watertight Integrity › General
Issued 22 February 2008
Resolved
Install manhole cover for the tunnel in the starboard rudder room
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 March 2008
Resolved 26 March 2008
Resolution: Cover is installed.
Stability › Weathertight Integrity › General
Issued 22 February 2008
Resolved
Fractured side shell plating IWO the 2nd window on port side. Temporary repair allowed until window is replaced OOA 14 Apr 08.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 April 2008
Resolved 16 April 2008
Resolution: Sited repairs on window
Communications › Alarms/Indicators › Bilge Alarm
Issued 22 February 2008
Resolved
Repair port engine room bilge high level alarm and demonstrate satisfactory operation.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 May 2008
Resolved 16 April 2008
Resolution: tested bilge system all Sat
Electrical › Electric Generation Source (service) › Ground Indicator
Issued 1 February 2008
Resolved
Main electrical distribution system, ground detection ondicates numerous 480V A/C grounds. Locate, isolate and repair grounds and/or ground detection system prior to the carriage of passengers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 1 February 2008
Resolution: Receive fax from master attesting that the ground detection system ha sbeen repaired.
Electrical › Electric Generation Source (service) › Ground Indicator
Issued 1 February 2008
Resolved
Troubleshoot ground detection system to ensure that it functions properly.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 April 2008
Resolved 7 April 2008
Resolution: Ground properly repaired. All Sat.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Governor
Issued 1 February 2008
Resolved
Repair or replace # 2 MDE faulty RPM gauge
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 March 2008
Resolved 26 March 2008
Resolution: Gauge replaced.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 1 February 2008
Resolved
Install guards on all rotating machinery in both engine room
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 March 2008
Resolved 26 March 2008
Resolution: Guards are installed.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 1 February 2008
Resolved
Remove excess water from te stbd engineroom bilges.
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 March 2008
Resolved 26 March 2008
Resolution: Water has beem removed.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 3 December 2007
Resolved
#3 Middle void has 2 fuel pipes that are incorrectly installed. Fuel pipe penetrations must have a pipe sleeve or stuffing tube installed at all bulkhead penetrations.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 December 2009
Resolved 31 October 2012
Resolution: #3 Middle voide fuel pipes installed properly.
Electrical › Electrical Distribution System (service) › Wiring
Issued 3 December 2007
Resolved
Properly secure wire/cables in port and starboard rudder rooms.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 January 2008
Resolved 22 March 2008
Construction/Loadline › Structures › Door
Issued 3 December 2007
Resolved
Repair broken gangway support unde port side main deck entrance door.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 21 January 2008
Resolved 22 March 2008
Construction/Loadline › Hull › Hull Plating
Issued 3 December 2007
Resolved
Back gouge and reweld insert, port side outboard side shell in port rudder room.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 21 January 2008
Resolved 22 February 2008
Resolution: The welding of the insert is completed
Construction/Loadline › Structures › Superstructure
Issued 3 December 2007
Resolved
Complete window frame and side-shell as per letter written by [name withheld], Suncruz Port Engineer on 12-21-07. Letter scanned into vessel documents section.
All windows on superstructure need renewed and shell plate repairs around window openings.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 December 2008
Resolved 22 June 2009
Resolution: Conducted hose test of the port windows (main and 2nd decks),test sat.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 11 September 2007
Resolved
Provide evidence of updated Fire Control Plan to reflect current outfitting of vessel. Accommodation spaces on Decks 1, 2, and 3 are not accurately reflected on posted plan dated from 1997. (Per 46 CFR 116.530)
Condition: Unknown
Due 21 January 2008
Resolved 22 March 2008
Accommodation/Occupational Safety › Ventilation › General
Issued 11 September 2007
Resolved
Remove all combustibles, cleaning solutions and gear from Auxiliary Machinery Spaces (HVAC), Category 12, which exceed .05 pounds per square foot. In the alternate, provide evidence that decks and bulkheads in those same spaces meet the Fire Control Boundary requirements of 46 CFR 116.415, as High Risk Service Spaces, Category 9.
Due 24 October 2007
Resolved 21 December 2007
Resolution: All combustibles were removed from space.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 22 January 2007
Resolved
Provide documentation that all stairway doors meet A-15 boundary requirements.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 26 January 2007
Resolved 22 August 2007
Fire Fighting › Structural - A Class Divisions › Doors
Issued 22 January 2007
Resolved
Renew/replace aft galley door with approved A-0 door.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 January 2007
Resolved 22 August 2007
Fire Fighting › Structural - A Class Divisions › Doors
Issued 22 January 2007
Resolved
Provide documentation that doors on the second deck fore and aft meet A-0 requirements.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 26 January 2007
Resolved 22 August 2007
Lifesaving › Launching Appliances › Davit
Issued 22 January 2007
Resolved
Provide proof/documentation that the rescue boat davit has been serviced and tested IAW 46 CFR 199.190(f)(i)and (j).
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 January 2007
Resolved 1 February 2007
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 22 January 2007
Resolved
Properly repair starboard main engine leaking exhaust pipe.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 January 2007
Resolved 29 January 2007
Engineering › Sea-water System (primary cooling) › Piping
Issued 22 January 2007
Resolved
Properly repair generator exhaust cooling water supply pipe.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 January 2007
Resolved 29 January 2007
Navigation › Piloting/Steering › Compass Deviation Table
Issued 18 January 2006
Resolved
Swing compass and provide current deviation table.
Action required: 705 - Other - as specified
Due 18 February 2006
Resolved 16 February 2006
Lifesaving › Buoyant Apparatus › Readily Accessible
Issued 18 January 2006
Resolved
Renew support stanchions for life floats.
Action required: 705 - Other - as specified
Due 18 February 2006
Resolved 16 February 2006
Construction/Loadline › Structures › Superstructure
Issued 18 January 2006
Resolved
Crop and renew 3rd frame, stbd side bridge wing and port bridge wing where bondo is applied.
Action required: 705 - Other - as specified
Due 18 February 2006
Resolved 16 February 2006
Fire Fighting › Structural - A Class Divisions › Open Deck Spaces
Issued 18 January 2006
Resolved
Replace "A" class door, main deck aft, starboard side.
Action required: 705 - Other - as specified
Due 16 March 2006
Resolved 18 January 2006
Electrical › Electric Generation Source (emergency) › Generator Cable
Issued 18 January 2006
Resolved
Support and route emergency generator cable IAW NEC.
Action required: 705 - Other - as specified
Due 18 February 2006
Resolved 16 March 2006
Lifesaving › Rescue Boat › Propulsion Engine
Issued 8 July 2005
Resolved
Prove proper operation o rescue boat prior and conduct man overboard drill.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 July 2005
Resolved 9 July 2005
Resolution: Install and tested newly purchase engine with satisfactory results.
Construction/Loadline › Penetrations › Pipe Flange
Issued 11 March 2004
Resolved
Bow thruster ventalation duct work wasted
Condition: Unknown
Due 10 April 2004
Resolved 15 February 2005
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 11 March 2004
Resolved
Submitt for approval Fire Control plan as per vessel
Due 10 April 2004
Resolved 15 February 2005
Engineering › Steering Gear System
Issued 8 September 2003
Resolved
Port rudder bent, reading show that rudder is 2 1/16 from center, also found soft patch on bottom of hull, make perm repairs to rudder, hull conduct test Marine inspector present LEGACY COMPONENT DESC: Rudder
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 September 2003
Resolved 17 September 2003
Construction/Loadline › Structures › Deck Plating
Issued 8 September 2003
Resolved
Port side fwd hull had servere set, replace still fwd, stbd laz found wasted still (flat bar) 10x8 two each, exhaust mixing boxs wasted, various salt water piping for the chill unit and J/W to the MDE wasted replace in kind
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 September 2003
Resolved 17 September 2003
Accommodation/Occupational Safety › Messroom
Issued 8 September 2003
Resolved
Two large cylinders were found in galley tied with rope, vsl to remove or make bracket. LEGACY COMPONENT DESC: Location
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 September 2003
Resolved 23 September 2003
Construction/Loadline › Penetrations
Issued 8 September 2003
Resolved
Upper tonnage door wasted around frame, vsl to replace door in kind, remove gasket seal metal to metal, also replace J bolts LEGACY COMPONENT DESC: Weld
Due 16 October 2003
Resolved 26 September 2003
Stability › Unintentional Flooding
Issued 8 September 2003
Resolved
Both port stbd void fwd of collision bulkhead valves not operarting from above.
Due 29 September 2003
Resolved 26 September 2003
Construction/Loadline › Penetrations
Issued 8 September 2003
Resolved
Ballast mainfold had C clamp installed remove C clamp from ballast mainiflod LEGACY COMPONENT DESC: Pipe Flange
Due 29 September 2003
Resolved 23 September 2003
Engineering › Diesel Engine (auxiliary)
Issued 8 September 2003
Resolved
F/O leak found on elbow for bow thruster under deck plate LEGACY COMPONENT DESC: Injector (fuel injection)
Due 29 September 2003
Resolved 17 September 2003
Engineering › Bilge Water Management System
Issued 8 September 2003
Resolved
Bilge strainer # 4 void missing from piping LEGACY COMPONENT DESC: Strainer
Due 30 September 2003
Resolved 23 September 2003
Electrical › Electric Supply System (service) › Cable
Issued 8 September 2003
Resolved
Elect cable not in proper hangers
Due 29 September 2003
Resolved 17 September 2003
Electrical › Electric Supply System (service)
Issued 8 September 2003
Resolved
Elect waste oil pumps not properly mounted, wire junction box stuffing gland not present.
Due 29 September 2003
Resolved 23 September 2003
Pollution Prevention/Response › Prevention Equipment
Issued 8 September 2003
Resolved
MARK PERMANENT REPAIRS TO THE DIRTY OIL DISCHARGE PIPING WHERE TEMPORARY PATCH IS IN PLACE. LEGACY COMPONENT DESC: Oily Mixture Discharge Fixed Piping System
Due 25 October 2003
Resolved 23 October 2003
Fire Fighting › Ventilation Systems
Issued 8 September 2003
Resolved
Fire dampers in entrance to stbd side SSDG space not working (spring not hooked up). LEGACY COMPONENT DESC: Duct Hatches
Due 29 September 2003
Resolved 26 September 2003
Engineering › Sea-water System (primary cooling)
Issued 8 September 2003
Resolved
Salt water piping for A/C and MDE cooling has variuos soft pacths all over, temp repairs made by ships force. LEGACY COMPONENT DESC: Piping
Due 29 September 2003
Resolved 26 September 2003
Engineering › Fuel Oil Storage/Transfer System
Issued 8 September 2003
Resolved
F/O piping leaking at variuos locations in # 3 void, P/W void stbd side, and Bow thruster engine. LEGACY COMPONENT DESC: Piping
Due 29 September 2003
Resolved 23 September 2003
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 8 September 2003
Resolved
Exhaust system leak in overhead at Y piping, LEGACY COMPONENT DESC: Piping (exhaust)
Due 29 September 2003
Resolved 26 September 2003
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 8 September 2003
Resolved
Fire stop/ Packing missing from wire runs located in crossover between hull
Due 29 September 2003
Resolved 17 September 2003
Construction/Loadline › Penetrations › Gasket
Issued 8 September 2003
Resolved
Gasket material found on lower and upper level tonnage doors port side
Due 29 September 2003
Resolved 17 September 2003
Construction/Loadline › Penetrations
Issued 8 September 2003
Resolved
Vent piping leading into void space fwd of collision bukhead wasted. LEGACY COMPONENT DESC: Pipe Flange
Due 29 September 2003
Resolved 23 September 2003
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 8 September 2003
Resolved
SFP missing from space fwd mid ship and stbd side machine space
Due 29 September 2003
Resolved 17 September 2003
Electrical › Electrical Distribution System (service)
Issued 8 September 2003
Resolved
Various cables laying on cieling tiles. Vsl has six months to complete and properly hang cables in the overhead. LEGACY COMPONENT DESC: Cable
Due 25 March 2004
Resolved 10 March 2004
Resolution: Cleared during U/W annual exam JACMS.
Engineering › Sea-water System (primary cooling)
Issued 8 September 2003
Resolved
MAKE PERMAMENT REPAIRS TO THE SOFT PATCH IN THE PORT SIDE GENERATOR DISCHARGE PIPE. LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Due 30 September 2003
Resolved 23 October 2003
Engineering › Generator (propulsion-electric)
Issued 25 February 2003
Resolved
Prior to 15MAR03, provide S/S generator with 50 Degree rating or derate to 80% or demonstrate E/R ambt Temp does not exceed 40 degrees.
Action required: 705 - Other - as specified
Due 15 March 2003
Resolved 3 March 2003
Resolution: Owner provided documentation from manufacturer indicating a 5% derating with appropriate over-current protection was sufficient. [name withheld] concurred.
Fire Fighting › Ventilation Systems
Issued 25 February 2003
Resolved
Prior to 28FEB03, ensure all fire dampeners are labeled for open and closed position.
Action required: 705 - Other - as specified
Due 28 February 2003
Resolved 3 March 2003
Resolution: Done.
Fire Fighting › Ventilation Systems
Issued 25 February 2003
Resolved
Prior to 28FEB03, ensure fire dampener for STBD MDE is functional.
Action required: 705 - Other - as specified
Due 28 February 2003
Resolved 3 March 2003
Resolution: Done.
Engineering › Fuel Oil Storage/Transfer System
Issued 25 February 2003
Resolved
Prior to 28FEB03, ensure all emergency F/O shutoff valves are functional.
Action required: 705 - Other - as specified
Due 28 February 2003
Resolved 3 March 2003
Resolution: Done.
Engineering › Fuel Oil Storage/Transfer System
Issued 25 February 2003
Resolved
Repair F/O leaks on supply and return in port sanitation space.
Action required: 705 - Other - as specified
Due 10 March 2003
Resolved 3 March 2003
Resolution: Done.
Engineering › Fuel Oil Service System
Issued 25 February 2003
Resolved
Provide Label for emergency shutoff in cage.
Action required: 705 - Other - as specified
Due 5 March 2003
Resolved 3 March 2003
Resolution: Done.
Engineering › Shafting/Propeller Arrangements
Issued 25 February 2003
Resolved
Adjust packing on the STBD rudder. LEGACY COMPONENT DESC: Stern Gland
Action required: 705 - Other - as specified
Due 5 March 2003
Resolved 3 March 2003
Resolution: Done.
Documentation › Safety/Response Plans/Programs
Issued 25 February 2003
Resolved
Update fire control plan to include information required by 46 CFR 116.530. LEGACY COMPONENT DESC: Fire Control Plans
Action required: 705 - Other - as specified
Due 10 March 2003
Resolved 3 March 2003
Resolution: Done.
Fire Fighting › Combustible Materials
Issued 25 February 2003
Resolved
Remove or provide approved locker for all flammable stores. LEGACY COMPONENT DESC: Paints/Varnishes/Other Finishes
Action required: 705 - Other - as specified
Due 10 March 2003
Resolved 3 March 2003
Resolution: Done.
Documentation › Certificates/Documents
Issued 25 February 2003
Resolved
Provide valid FCC radiotelephony Certificate.
Action required: 705 - Other - as specified
Due 10 March 2003
Resolved 3 March 2003
Resolution: Done.
Lifesaving › Rescue Boat
Issued 25 February 2003
Resolved
Provide spec sheet for rescue boat davit falls.
Action required: 705 - Other - as specified
Due 10 March 2003
Resolved 3 March 2003
Resolution: Done.
Lifesaving › Buoyant Apparatus
Issued 25 February 2003
Resolved
Repair life floats were coating is damaged.
Action required: 705 - Other - as specified
Due 10 March 2003
Resolved 3 March 2003
Resolution: Done.
Lifesaving › Buoyant Apparatus
Issued 25 February 2003
Resolved
Repair/replace life float sea painter canister where damaged.
Action required: 705 - Other - as specified
Due 10 March 2003
Resolved 3 March 2003
Resolution: Done.
Documentation › Safety/Response Plans/Programs
Issued 11 February 2002
Resolved
Provide renewed/legible Fire Control Plan #26-642-3555 dated 02 Mar 97. LEGACY COMPONENT DESC: Fire Control Plans
Condition: Improper/Lack of Maintenance
Due 11 March 2002
Resolved 27 August 2002
Resolution: Rcvd written confirmation from vsl master item corrected.
Documentation › Logs/Records
Issued 11 February 2002
Resolved
Provide documentation that the fixed fire-fighting system received complete servicing in 2001.
Condition: Unknown
Due 26 February 2002
Resolved 12 February 2002
Documentation › Logs/Records
Issued 11 February 2002
Resolved
Make available drug testing record to a Coast Guard marine inspector. LEGACY COMPONENT DESC: Drug Test Records
Condition: Unknown
Due 26 February 2002
Resolved 25 February 2002
Accommodation/Occupational Safety › Refrigeration (air conditioning)
Issued 11 February 2002
Resolved
Replace lines on chiller/condensate system located port side where wasted.
Condition: Improper/Lack of Maintenance
Due 26 February 2002
Resolved 12 March 2002
Electrical › Lighting (emergency)
Issued 11 February 2002
Resolved
Properly run all electrical outlets in way of bar, port side main deck and emergency lights in workshop. LEGACY COMPONENT DESC: Outlet Box
Condition: Improper/Lack of Maintenance
Due 11 March 2002
Resolved 12 March 2002
Fire Fighting › Ventilation Systems
Issued 11 February 2002
Resolved
Repair fire damper, main ventilation port side of E/R where systems failed to function. LEGACY COMPONENT DESC: Ducts
Condition: Improper/Lack of Maintenance
Due 11 March 2002
Resolved 12 March 2002
Fire Fighting › Ventilation Systems
Issued 11 February 2002
Resolved
Repair shutdown for port side galley exhaust where louvres fail to close/shut. LEGACY COMPONENT DESC: Exhaust Ducts (Galley Ranges)
Condition: Improper/Lack of Maintenance
Due 11 March 2002
Resolved 12 March 2002
Accommodation/Occupational Safety › Occupational Safety
Issued 11 February 2002
Resolved
Correct housekeeping in all engine spaces and CO2 room port side.
Condition: Improper/Lack of Maintenance
Due 26 February 2002
Resolved 12 March 2002
Operations/Management › Passenger Operations
Issued 11 February 2002
Resolved
Permanently mount cigarette machine to bulkhead to prevent system from falling on passengers.
Condition: Improper/Lack of Maintenance
Due 26 February 2002
Resolved 12 March 2002
Engineering › Fuel Oil Service System
Issued 11 February 2002
Resolved
Repair/replace hydraulic lines and actuator controls where wasted and failing. LEGACY COMPONENT DESC: Hose
Condition: Improper/Lack of Maintenance
Due 11 April 2002
Resolved 27 August 2002
Resolution: Rcvd written confirmation from vsl master item had been corrected.
Lifesaving › Buoyant Apparatus
Issued 11 February 2002
Resolved
Repair/replace three deteriorated lifefloats as indentified to Master. LEGACY COMPONENT DESC: Lifefloats
Condition: Improper/Lack of Maintenance
Due 26 February 2002
Resolved 12 March 2002
Navigation
Issued 6 September 2001
Resolved
have compass calabrated and update deviation table.
Condition: Unknown
Due 6 October 2001
Resolved 17 September 2001
Construction/Loadline
Issued 6 September 2001
Resolved
Install and prove proper operation of bilge high level alarms.
Condition: Unknown
Due 6 October 2001
Resolved 11 February 2002
Deck/Cargo
Issued 6 September 2001
Resolved
Load test rescue boat davit.
Condition: Unknown
Due 6 October 2001
Resolved 27 September 2001
Construction/Loadline
Issued 14 March 2001
Resolved
Prior to the carriage of passengers, insure all main deck hatches are secured and prior to 01APR01, install signs directing crew members to lock after each entry.
Condition: Unknown
Due 14 March 2001
Resolved 14 March 2001
Construction/Loadline
Issued 17 January 2001
Resolved
During August 2001 drydock, conduct permanent repair to 4 holes in No. 4 port ballast tank.
Condition: Unknown
Due 17 January 2001
Resolved 17 January 2001
Unknown
Issued 17 January 2001
Resolved
Prior to 10FEB01, provide permanent repair to dirty oil piping in vicinity of the NO. 3 ballast tank.
Condition: Unknown
Due 17 January 2001
Resolved 17 January 2001
Construction/Loadline
Issued 17 January 2001
Resolved
Prior to 10FEB2001, provide temp repair for two additional holes in port side NO. 4 ballast tank.
Condition: Unknown
Due 17 January 2001
Resolved 17 January 2001
Accommodation/Occupational Safety
Issued 17 January 2001
Resolved
Prior to 10FEB01, renew ladders in port and starboard No. 3 Ballast Tanks.
Condition: Unknown
Due 17 January 2001
Resolved 17 January 2001
Documentation
Issued 25 January 2000
Resolved
Prior to 02FEB00, include all survival craft and launching appliances in weekly/monthly maintenance checks.
Condition: Unknown
Due 2 February 2000
Resolved 1 February 2000
Accommodation/Occupational Safety
Issued 25 January 2000
Resolved
Remove crew berthing accomodations from starboard stairwell locker on the main deck. The overnight watchman was using this space for berthing.
Condition: Unknown
Due 2 February 2000
Resolved 1 February 2000
Electrical
Issued 25 January 2000
Resolved
Prior to 02FEB00, repair electrical cables with exposed wiring on uppermostdeck port side, forward.
Condition: Unknown
Due 2 February 2000
Resolved 1 February 2000
Accommodation/Occupational Safety
Issued 25 January 2000
Resolved
When in US waters, keep MSD overboard valves in the closed and locked position.
Condition: Unknown
Due 2 February 2000
Resolved 1 February 2000
Fire Fighting
Issued 25 January 2000
Resolved
Prior to 02FEB00, properly mark all fire alarm call points throughout the vessel.
Condition: Unknown
Due 2 February 2000
Resolved 1 February 2000
Lifesaving
Issued 25 January 2000
Resolved
Prior to 02FEB00, repair door latch on aft galley door, main deck.
Condition: Unknown
Due 2 February 2000
Resolved 1 February 2000
Electrical
Issued 3 January 1999
Resolved
Prior to 02 FEB 99, remove paper labels of all breakers inside electrical panels.
Condition: Unknown
Due 2 February 1999
Resolved 2 February 1999
Fire Fighting
Issued 3 January 1999
Resolved
Prior to 11 FEB 99, clean off paint on all fire detectors. _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 3 January 1999
Resolved 3 January 1999
Documentation
Issued 3 January 1999
Resolved
Prior to 11 FEB 99, post entire Cetificate of Inspection.
Condition: Unknown
Due 2 February 1999
Resolved 2 February 1999
Lifesaving
Issued 3 January 1999
Resolved
Prior to 11 FEB 99, make life jacket stowage boxes unlockable.
Condition: Unknown
Due 2 February 1999
Resolved 2 February 1999
Lifesaving
Issued 3 January 1999
Resolved
Prior to 11 FEB 99, mark all lifefloats with capacity and vessels name.
Condition: Unknown
Due 2 February 1999
Resolved 2 February 1999
Lifesaving
Issued 3 January 1999
Resolved
Prior to 11 FEB 99, stow lifefloats IAW 46CFR117.137.
Condition: Unknown
Due 2 February 1999
Resolved 2 February 1999
Lifesaving
Issued 3 January 1999
Resolved
Prior to 11 FEB 99, provide/modify station bill with man overboard proceedures.
Condition: Unknown
Due 2 February 1999
Resolved 2 February 1999
Navigation
Issued 3 January 1999
Resolved
Prior to 11 FEB 99, provide tide tables and tidal current tables.
Condition: Unknown
Due 2 February 1999
Resolved 2 February 1999
Electrical
Issued 3 January 1999
Resolved
Prior to 11 FEB 99, remove dead end wires, STBD side, bow thruster room.
Condition: Unknown
Due 3 January 1999
Resolved 3 January 1999
Accommodation/Occupational Safety
Issued 3 January 1999
Resolved
Prior to 11 FEB 99, provide pins for all locking mechanisms on all main deck scuttle hatches.
Condition: Unknown
Due 2 February 1999
Resolved 2 February 1999
Construction/Loadline
Issued 3 January 1999
Resolved
Prior to 11 FEB 99, provide and post emergency steering valve placement in after steering space.
Condition: Unknown
Due 2 February 1999
Resolved 2 February 1999
Construction/Loadline
Issued 3 January 1999
Resolved
Prior to 11 FEB 99, provide draft marks in contrasting color to the sideshell paint.
Condition: Unknown
Due 2 February 1999
Resolved 2 February 1999
Lifesaving
Issued 3 January 1999
Resolved
Prior to 11 FEB 99, place paint cans in an approved flammable stowage locker, not in a container that is the same as life preservers.
Condition: Unknown
Due 2 February 1999
Resolved 2 February 1999
Documentation
Issued 3 January 1999
Resolved
Prior to 08 Feb 99, provide a chemical testing program.
Condition: Unknown
Due 3 February 1999
Resolved 4 February 1999
Fire Fighting
Issued 3 January 1999
Resolved
Prior to 11 FEB 99, prove proper engine shut-downs via fixed fire extinguishing system.
Condition: Unknown
Due 2 February 1999
Resolved 2 February 1999
Engineering
Issued 3 January 1999
Resolved
Prior to 11 FEB 99, provide additional packing on PORT shaft packing tube.
Condition: Unknown
Due 2 February 1999
Resolved 2 February 1999
Fire Fighting
Issued 3 January 1999
Resolved
Prior to 11 FEB 99, label CO2 room "CARBON DIOXIDE FIRE EXTINGUISHING APPARATUS".
Condition: Unknown
Due 2 February 1999
Resolved 2 February 1999
Lifesaving
Issued 3 January 1999
Resolved
Prior to 11 FEB 99, provide light fixture cover for STBD deck machinery room.
Condition: Unknown
Due 2 February 1999
Resolved 2 February 1999
Electrical
Issued 3 January 1999
Resolved
Prior to 11 FEB 99, provide a junction box cover at 2nd deck, PORT side machinery room.
Condition: Unknown
Due 2 February 1999
Resolved 2 February 1999
Lifesaving
Issued 3 January 1999
Resolved
Prior to 11 FEB 99, remove flammable materials from all emergency escape stairtowers.
Condition: Unknown
Due 2 February 1999
Resolved 2 February 1999
Electrical
Issued 3 January 1999
Resolved
Prior to 11 FEB 99, instal/provide anti-chaffing material around wire for 2nd deck, PORT side, CO2 room.
Condition: Unknown
Due 2 February 1999
Resolved 2 February 1999
Accommodation/Occupational Safety
Issued 3 January 1999
Resolved
Prior to 11 FEB 99, make loading doors weathertight.
Condition: Unknown
Due 2 February 1999
Resolved 2 February 1999
Electrical
Issued 3 January 1999
Resolved
Prior to 11 FEB 99, provide stuffing tubes for 12volt battery storage and distribution box.
Condition: Unknown
Due 2 February 1999
Resolved 2 February 1999
Lifesaving
Issued 30 January 1998
Resolved
Provide proper tending lines (bow & stern) including length and weighted throwing means for the rescue boat.
Condition: Unknown
Due 30 January 1998
Resolved 30 January 1998
Fire Fighting
Issued 30 January 1998
Resolved
Provide log book for fire fighting/life saving equipment maintenance inspections.
Condition: Unknown
Due 30 January 1998
Resolved 30 January 1998
Lifesaving
Issued 30 January 1998
Resolved
Provide "Maximum Passengers Allowed" placards for 01 and 02 decks (395 passengers maximum are allowed on 01 deck, 402 passengers maximum are allowed on 02 deck).
Condition: Unknown
Due 30 January 1998
Resolved 30 January 1998
Lifesaving
Issued 30 January 1998
Resolved
Incorporate procedures for handling elevator/passengers during emergencies.
Condition: Unknown
Due 30 January 1998
Resolved 30 January 1998
Electrical
Issued 30 January 1998
Resolved
Prove proper operation of emergency lighting on all decks.
Condition: Unknown
Due 30 January 1998
Resolved 30 January 1998
Fire Fighting
Issued 30 January 1998
Resolved
Properly label ventilation shutdowns/fire screen door closure controls on bridge.
Condition: Unknown
Due 30 January 1998
Resolved 30 January 1998
Lifesaving
Issued 30 January 1998
Resolved
Properly secure lifejacket storage boxes on 0-1 deck.
Condition: Unknown
Due 30 January 1998
Resolved 30 January 1998
Lifesaving
Issued 30 January 1998
Resolved
Modify station bill to incorporate man overboard & abandonship emergencies.
Condition: Unknown
Due 30 January 1998
Resolved 30 January 1998
Navigation
Issued 30 January 1998
Resolved
Provide a valid FCC Safety certificate.
Condition: Unknown
Due 30 January 1998
Resolved 30 January 1998
Construction/Loadline
Issued 8 January 1998
Resolved
MAKE APPROVED REPAIRS TO THE BALLAST SENSOR SYSTEM IN THE PILOTHOUSE.
Condition: Unknown
Due 8 January 1998
Resolved 8 January 1998
Documentation
Issued 8 January 1998
Resolved
PROVIDE COAST GUARD APPROVED PLANS FOR HULL MODIFICATIONS TO THE BOTTOM OF THE PORT/STBD PONTOONS IN THE AREA JUST FORWARD ON THE PROPELLERS.
Condition: Unknown
Due 8 January 1998
Resolved 8 January 1998
Deck/Cargo
Issued 8 January 1998
Resolved
CONDUCT OPERATIONAL TEST OF ANCHORING EQUIPMENT TO ENSURE PROPER OPERATION.
Condition: Unknown
Due 8 January 1998
Resolved 8 January 1998