Records from 2003 to 2017. Most recent: inspection, 27 February 2017.
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 25 January 2017
No resolution recorded
Provide updated Station Bill to reflect special duties and duty stations of each crew member. 46 CFR 122.514
Action required: 701 - Prior to carriage of passengers/cargo
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 25 January 2017
No resolution recorded
Make available all paperwork and records for the vessel’s Drug and Alcohol Program. 46 CFR 16
Action required: 701 - Prior to carriage of passengers/cargo
Personnel › Certificates/Documents/Licenses › TWIC
Issued 25 January 2017
No resolution recorded
Make available for inspection the TWIC card of all vessel personnel responsible for security duties as outlined in vessel VSP. 33 CFR 104.220
Action required: 701 - Prior to carriage of passengers/cargo
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 25 January 2017
No resolution recorded
Make available for inspection all charts and nautical publications for the area of vessel’s intended voyage to as required by 46 CFR 121.420
Action required: 701 - Prior to carriage of passengers/cargo
Construction/Loadline › Structures › Door
Issued 25 January 2017
No resolution recorded
Prove proper operation and condition of all fire doors within the vessel. 46 CFR 116.435
Action required: 701 - Prior to carriage of passengers/cargo
Construction/Loadline › Structures › Door
Issued 25 January 2017
No resolution recorded
Prove proper operation and condition of all watertight weathertight doors or hatches within the vessel. 46 CFR 116.1160
Action required: 701 - Prior to carriage of passengers/cargo
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 25 January 2017
No resolution recorded
Provide at least one ring life buoy with a lifeline of the type specified in 46 CFR 117.70.
Action required: 701 - Prior to carriage of passengers/cargo
Fire Fighting › Firemans Outfit › Axe
Issued 25 January 2017
No resolution recorded
Provide a fire axe in or adjacent to the primary operating station. 46 CFR 118.600
Action required: 701 - Prior to carriage of passengers/cargo
Operations/Management › Vessel Activity › Underway
Issued 25 January 2017
No resolution recorded
Provide means of meeting the passenger count communication requirement required by 46 CFR 122.504. 46 CFR 122.504
Action required: 701 - Prior to carriage of passengers/cargo
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 25 January 2017
No resolution recorded
Provide updated emergency evacuation plan and fire control plan to reflect vessel’s configuration. 46 CFR 116.520/530
Action required: 701 - Prior to carriage of passengers/cargo
Fire Fighting › Ventilation Systems › Operating Controls
Issued 25 January 2017
No resolution recorded
Provide means of shutting down power ventilation system from the pilot house. 46 CFR 116.600
Action required: 701 - Prior to carriage of passengers/cargo
Engineering › Fuel Oil Service System › Piping
Issued 25 January 2017
No resolution recorded
Make permanent repairs to starboard generator fuel supply piping
Action required: 701 - Prior to carriage of passengers/cargo
Engineering › Sea-water System (primary cooling) › Piping
Issued 25 January 2017
No resolution recorded
Make permanent repairs to starboard a/c unit's seawater piping
Action required: 701 - Prior to carriage of passengers/cargo
Deck/Cargo › Ballast › Vents
Issued 25 January 2017
No resolution recorded
Make permanent repairs to all wasted ballast tank vents
Action required: 701 - Prior to carriage of passengers/cargo
Construction/Loadline › Penetrations › Weld
Issued 25 January 2017
No resolution recorded
Make permanent repairs to wasted deck drain piping and side shell connections
Action required: 701 - Prior to carriage of passengers/cargo
Electrical › Lighting (emergency) › Lighting Fixture
Issued 25 January 2017
No resolution recorded
Prove proper operation of emergency lighting
Action required: 701 - Prior to carriage of passengers/cargo
Documentation › Certificates/Documents › Certificate of Inspection
Issued 25 January 2017
Resolved
Conduct drydock and internal structual exams for credit
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 February 2017
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 25 January 2017
No resolution recorded
Remove electric blowers from port and starboard sewage tank vents
Action required: 701 - Prior to carriage of passengers/cargo
Engineering › Fuel Oil Service System › Suction Strainer
Issued 25 January 2017
No resolution recorded
Install marine grade fuel strainer for bow thruster
Action required: 701 - Prior to carriage of passengers/cargo
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 25 January 2017
No resolution recorded
Install guard on bow thruster shaft
Action required: 701 - Prior to carriage of passengers/cargo
Fire Fighting › Ventilation Systems › Ducts
Issued 25 January 2017
No resolution recorded
Make permanent repairs to all wasted ventilation ducts.
Action required: 701 - Prior to carriage of passengers/cargo
Stability › Weathertight Integrity › General
Issued 25 January 2017
No resolution recorded
Make repairs to all wasted window frames through out vessel
Action required: 701 - Prior to carriage of passengers/cargo
Fire Fighting › Structural Fire Protection - General › Deckhouse Construction
Issued 25 January 2017
No resolution recorded
Repair/Renew all wasted fire screen doors and door frames
Action required: 701 - Prior to carriage of passengers/cargo
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 25 January 2017
No resolution recorded
Make permanent repairs to starboard propulsion engine's seawater overboard pipe flange at exhaust connection
Action required: 701 - Prior to carriage of passengers/cargo
Stability › Watertight Integrity › General
Issued 25 January 2017
No resolution recorded
Crop and renew all wasted deck in CO2 room
Action required: 701 - Prior to carriage of passengers/cargo
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 25 January 2017
No resolution recorded
Crop and renew wasted bulkhead that seperates galley and port engine compartment
Action required: 701 - Prior to carriage of passengers/cargo
Lifesaving › Launching Appliances › Davit
Issued 25 January 2017
No resolution recorded
Renew rescue boat davit
Action required: 701 - Prior to carriage of passengers/cargo
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 25 January 2017
No resolution recorded
Remove latch from PFD storage boxes to prevent boxes from being locked
Action required: 701 - Prior to carriage of passengers/cargo
Operations/Management › Drills/Instruction › Fire
Issued 25 January 2017
No resolution recorded
Conduct man overboard, security and fire drills
Action required: 701 - Prior to carriage of passengers/cargo
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 25 January 2017
No resolution recorded
Have fixed extinguishing systems serviced and time delays tested by certified technician in the presence of attending marine inspector
Action required: 701 - Prior to carriage of passengers/cargo
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 25 January 2017
No resolution recorded
Make repairs to inoperable fire dampers
Action required: 701 - Prior to carriage of passengers/cargo
Engineering › Steering Gear System › Actuator
Issued 25 January 2017
No resolution recorded
Overhaul/renew steering system
Action required: 701 - Prior to carriage of passengers/cargo
Engineering › Bilge Water Management System › Not Operational
Issued 25 January 2017
No resolution recorded
Prove proper operation of bilge system for the following spaces: both forepeaks, void 4 aft stbd side, steering space stbd side and void 2 port side. 46 CFR 119.510
Action required: 701 - Prior to carriage of passengers/cargo
Documentation › Logs/Records › Operational Procedures for Engines or Equipment
Issued 25 January 2017
No resolution recorded
Provide approved Design Verification and Periodic Safety test procedures for propulsion engines
Action required: 701 - Prior to carriage of passengers/cargo
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 25 January 2017
No resolution recorded
Make repair (weld broken at deck connection) to ladder leading into void 4 stbd side. 46 CFR 116.100
Action required: 701 - Prior to carriage of passengers/cargo
Engineering › Bilge Water Management System › Pump
Issued 25 January 2017
No resolution recorded
Prove proper operation of second power-driven bilge pump in port engine room space. 46 CFR 119.520
Action required: 701 - Prior to carriage of passengers/cargo
Engineering › Bilge Water Management System › Piping
Issued 25 January 2017
No resolution recorded
Remove nonmetallic (PVC) piping from installed bilge system
Action required: 701 - Prior to carriage of passengers/cargo
Construction/Loadline › Hull › Side Shell
Issued 1 August 2016
Resolved
Prior to carrying passengers, complete repairs to hull damage incurred during docking.
Action required: 705 - Other - as specified
Resolved 29 August 2016
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 25 January 2016
Resolved
Air handler rooms on decks 1 and 2 must be insulated with approved type insulation in accordance with fire control plan.
Action required: 705 - Other - as specified
Due 24 February 2016
Resolved 26 February 2016
Resolution: Rooms have been insulated.
Fire Fighting › Miscellaneous Items › Paint/Flammable Liquid Lockers
Issued 25 January 2016
Resolved
Remove all combustable materials from air handler room.
Action required: 705 - Other - as specified
Due 1 February 2016
Resolved 27 January 2016
Resolution: All flammables and combustables have been removed.
Engineering › Steering Gear System › Ram Seal
Issued 25 January 2016
Resolved
Repair oil leak on port rudder ram.
Due 1 February 2016
Resolved 27 January 2016
Resolution: Leak on steering actuator has been repaired.
Engineering › Steering Gear System › Bracket/Clamp
Issued 25 January 2016
Resolved
Repair cracked welds on rudder supports, port rudder.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 January 2016
Resolution: Cracks on rudder supports have been repaired by grinding and rewelding.
Engineering › Fuel Oil Service System › Filter
Issued 25 January 2016
Resolved
Repair fuel leak on the fuel filter housing for both the port and stbd main engines.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 January 2016
Resolution: Fuel leak has been repaired
Fire Fighting › Grease Extraction Hood › General
Issued 25 January 2016
Resolved
Clean range hoods and grease traps.
Due 1 February 2016
Resolved 27 January 2016
Resolution: Grease traps and range hoods have been cleaned.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 25 January 2016
Resolved
Properly secure CO2 extinguishers (2) in port engine room entrance.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 January 2016
Resolution: Fire extinguisher has been properly secured.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 25 January 2016
Resolved
prove proper operation of emergency light in port generator room.
Due 25 February 2016
Resolved 27 January 2016
Resolution: Proved proper operation of emergency light in port generator room.
Stability › Watertight Integrity › General
Issued 25 January 2016
Resolved
Prove proper operation of all deck hatches securing device.
Due 25 February 2016
Resolved 26 February 2016
Resolution: Proved proper operation of all deck hatch securing devices.
Fire Fighting › Fixed Fire Detection System › Annual Inspection
Issued 25 January 2016
Resolved
Prove proper operation of fixed fire detection system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 January 2016
Resolution: Proved proper operation of fixed fire detection system. Had system serviced while CGMI onboard.
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 25 January 2016
Resolved
Remove all flamables and combustables from electrical room.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 January 2016
Resolution: Removed all flamables and combustables from the electrical room.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 25 January 2016
Resolved
Prove proper operation af all fire screen doors.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 January 2016
Resolution: Proved proper operation of all fire screen doors.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 25 January 2016
Resolved
Re-secure toolbox being held up by nylon strap.
Due 25 February 2016
Resolved 27 January 2016
Resolution: Properly secured toolbox and removed temporary strap.
Electrical › Lighting (service) › Lighting Fixture
Issued 25 January 2016
Resolved
Repair broken light fixture on aft deck.
Due 25 February 2016
Resolved 27 January 2016
Resolution: Replaced broken fixture on aft deck.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 25 January 2016
Resolved
Secure hanging junction box on aft bulkhead in STBD engine room.
Due 25 February 2016
Resolved 27 January 2016
Resolution: Re-mounted junction box.
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 25 January 2016
Resolved
Re-install loose lagging on STBD MDE.
Due 25 February 2016
Resolved 27 January 2016
Resolution: Properly installed lagging.
Electrical › Electric Supply System (service) › Cable
Issued 25 January 2016
Resolved
Properly secure battery cable between battery banks.
Due 25 February 2016
Resolved 27 January 2016
Resolution: Properly secured battery cable.
Electrical › Electrical Distribution System (service) › Wiring
Issued 25 January 2016
Resolved
Remove all solid core wiring from vessel, noted in entrance to port engine room.
Due 25 February 2016
Resolved 27 January 2016
Resolution: Removed solid core wiring in port engine room entrance.
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 25 January 2016
Resolved
Repair wasted/holes steel bulkhead between mechanical room and co2 room.
Due 25 February 2016
Resolved 27 January 2016
Resolution: Installed new steel plate insert where wasted bulkhead was.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 25 January 2016
Resolved
Repair broken emergency light in STBD generator room.
Due 25 February 2016
Resolved 27 January 2016
Resolution: Proved proper operation of emergency light.
Engineering › Sea-water System (primary cooling) › Piping
Issued 25 January 2016
Resolved
Permanetly repair wasted/holes raw water piping for number 1 generator and chiller system, STBD side.
Due 25 February 2016
Resolved 26 February 2016
Resolution: Perminently repaired wasted piping.
Construction/Loadline › Structures › Door
Issued 25 January 2016
Resolved
Install missing handle on door under STBD staircase. (slot-room)
Due 25 February 2016
Resolved 26 February 2016
Resolution: Installed door handle.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 25 January 2016
Resolved
Post updated/accurate fire and safety plan throughout ship.
Action required: 705 - Other - as specified
Resolved 1 February 2016