MAURY USCG vessel records Sign in
← All vessels

VIKING STAR

VIKING STAR is a 1970 passenger vessel (inspected). The Coast Guard has recorded 87 inspections since 1984, most recently in May 2025, along with 167 deficiencies and 2 casualty investigations between 2010 and 2020.

Records from 1984 to 2025. Most recent: inspection, 22 May 2025.

Built
1970
Last inspected
22 May 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WY9034
Flag
UNITED STATES
367337990
Maury page id
psix-46574

Inspections, by type

…with no type recorded12
Years with a record 39 calendar years (1984–2025)
The 87 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)88.2 ft × 22.0 ft × 8.5 ft
Registered tonnagegross 87 / net 59
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBLOUNT MARINE CORPORATION · WARREN, RI, UNITED STATES · built 1970
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portMONTAUK, NY
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 24 March 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it87 - Regulatory (Subpart C or D), Gross Ton
59 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WY9034MMSI 367337990 · active · voluntarily equipped · granted 2 February 2018, expires 31 March 2028
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 87

22 May 2025 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8140926
29 April 2025 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8123842
31 March 2025 Drydock Exam · Internal Structural Exam · Deficiency Check · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8097506
4 April 2024 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7889515
31 May 2023 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7678673
14 February 2023 Examination of Repairs · Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7629252
23 January 2023 Examination of Repairs · Administrative Inspection · Plan Review "T" Boat
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7625519
19 April 2022 COI Inspection · DAPI Audit
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7430788
26 August 2021 Type not recorded
No type recorded · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7302733
12 July 2021 In-Service Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7257099
11 May 2021 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7193655
19 January 2021 Hull Examination · Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7119309
4 October 2020 Type not recorded
No type recorded · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7071264
7 July 2020 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7001278
10 October 2019 In-Service Inspection · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6831931
13 August 2019 Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6783415
18 July 2019 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6709633
11 February 2019 Examination of Repairs · Administrative Inspection · Deficiency Check · Hull Examination · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6623721
15 January 2019 In-Service Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6607284
13 September 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6539785
21 June 2018 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6427903
20 April 2017 Deficiency Check · COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6128863
11 January 2017 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6067035
5 July 2016 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 5921579
17 June 2014 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 4890539
30 May 2012 Type not recorded
No type recorded · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 4328929
16 May 2012 DAPI Audit · COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 4312425
29 November 2010 Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3900526
1 July 2009 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3520055
8 January 2009 In-Service Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3393992
25 November 2008 Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3364571
10 April 2008 MARPOL Annex V Examination · Re-Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3179813
11 April 2007 COI Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2906126
5 April 2006 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2616706
11 April 2005 Annual Inspection · Deficiency Check
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 2329503
2 December 2004 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2252195
28 May 2004 Type not recorded
No type recorded · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 2101721
15 April 2004 Annual Inspection · MARPOL Annex V Examination
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 2043366
26 January 2004 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1997743
2 August 2003 Type not recorded
No type recorded · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 1869525
15 April 2003 MARPOL Annex V Examination · Annual Inspection
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 1772034
25 March 2003 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1762167
3 August 2002 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1934353
28 May 2002 Administrative Inspection
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1621930
23 April 2002 COI Inspection · MARPOL Annex V Examination
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 1606767
26 June 2001 Re-Inspection · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1432539
22 March 2001 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1464359
20 March 2000 Re-Inspection · MARPOL Annex V Examination · Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1369582
19 January 2000 Hull Examination · Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1438958
21 January 1999 MARPOL Annex V Examination · COI Inspection · Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1124549
23 April 1998 MARPOL Annex V Examination · Re-Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1123869
13 January 1998 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1114386
11 December 1997 Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1116955
18 November 1997 Administrative
Administrative · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 774609
31 August 1997 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 157611
18 April 1997 Re-Inspection · MARPOL Annex V Examination · Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1116191
17 April 1996 MARPOL Annex V Examination · Deficiency Check · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1083928
2 April 1996 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 872504
29 March 1995 COI Inspection · Deficiency Check · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1172692
30 March 1994 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1168080
24 March 1994 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1168076
11 March 1994 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1448512
27 May 1993 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1136923
14 May 1993 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 842887
10 March 1993 COI Inspection · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 826137
20 May 1992 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 952470
6 January 1992 Deficiency Check · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1315268
2 July 1991 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 934679
24 June 1991 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1247891
3 June 1991 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1220374
3 January 1991 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 904196
3 January 1991 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1304923
3 January 1990 Deficiency Check · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 907761
20 December 1989 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1214545
15 November 1989 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1229568
2 February 1989 Deficiency Check · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1342630
12 April 1988 Deficiency Check · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1044713
31 July 1987 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1320007
2 June 1987 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1027195
2 June 1987 Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1027203
15 April 1987 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1008885
7 April 1987 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1027197
1 July 1986 Excursion Permit
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 986931
9 May 1986 Credit Drydock
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1304115
16 April 1986 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 986133
11 April 1985 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1286127
17 November 1984 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1283246

Deficiency record · 167

09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 22 May 2025 Resolved
Port side gen needs a guard.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 June 2025
Resolved 23 May 2025
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 May 2025 Resolved
E/R dist panel needs a blank
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 June 2025
Resolved 23 May 2025
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 31 March 2025 Resolved
Forepeak: Make watertight with metallic fasteners or permanently close the 2 through deck penetrations at the bow leading into the forepeak.
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 April 2025
Resolved 29 April 2025
09 - Working and Living Conditions › 091 - Living Conditions › Other (food)
Issued 31 March 2025 Resolved
Tank Space: Repair the 3 identified potable water piping leaks and provide for testing.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 April 2025
Resolved 29 April 2025
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 31 March 2025 Resolved
Main Deck: Replace forward window on the stbd side of the main deck cabin. Window is damaged and cracked from impact. 46 CFR 177.1020
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 May 2025
Resolved 29 April 2025
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 31 March 2025 Resolved
Upper Deck: Renew welds attaching bench seats to back supports on the two aft-most passenger benches on the upper deck. Welds are cracked in the horizontal seam of the end-support frames on both benches.
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 April 2025
Resolved 29 April 2025
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 31 March 2025 Resolved
Upper Deck: Renew passenger handrail support on the aft ladderwell to the upper deck. Weld is cracked in the base support of the metal rail where it meets the deck.
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 April 2025
Resolved 29 April 2025
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 31 March 2025 Resolved
Crop/Renew wasted ledge support on fwd bulwarks and tackle mounts on the stbd side.
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 April 2025
Resolved 29 April 2025
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 4 April 2024 Resolved
Radio not transmitting Lat and Long.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 April 2024
Resolved 19 April 2024
Resolution: Corrected
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 4 April 2024 Resolved
Light on life float inoperable.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 18 April 2024
Resolved 4 April 2024
Resolution: Corrected on the spot.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 11 May 2021 Resolved
Replace retro on life rings.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 May 2021
Resolved 11 May 2021
Resolution: Corrected on the spot.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 May 2021 Resolved
Remove wire nuts in engine room.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 May 2021
Resolved 11 May 2021
Resolution: Corrected on the spot.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 February 2021 Resolved
Electrical junction box in engine space overhead is improperly mounted and has 2 cut cables not properly secured. Properly mount or remove junction box & remove cut cables. Old T cite: 183.10-20 -> not listed in MISLE. Used New T cite below.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 February 2021
Resolved 11 May 2021
Resolution: MI attended vessel and cleared requirement.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 7 July 2020 Resolved
Prior to carrying more than 136 passengers replace lifejacket required to meet vessel outfit for passengers in crew as noted on COI.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 7 July 2020
Resolved 10 July 2020
Resolution: Replaced
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 7 July 2020 Resolved
Prior to operating on Oceans and Coastwise route provide approved lights for all lifejackets onboard.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 7 July 2020
Resolved 10 July 2020
Resolution: Added required lights.
09 - Working and Living Conditions › 091 - Living Conditions › Access/structure
Issued 10 October 2019 Resolved
Reconfigure bunk arrangement above emergency egress and install additional ladder rung to allow for rapid escape from bunk room in an emergency. (Prior to carrying overnight passengers.)
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 10 October 2019
Resolved 23 October 2019
Resolution: Reconfigured bunk arrangement above emergency egress and installed additional ladder rung to allow for rapid escape from bunk room in an emergency.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 10 October 2019 Resolved
Prove proper operation of emergency lighting in bunk room. (Prior to carrying overnight passengers.)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 October 2019
Resolved 18 October 2019
Resolution: Proved proper operation of emergency lighting in bunk room.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 10 October 2019 Resolved
Galleys must be surrounded by B-15 Class fire boundaries. Either install approved class B-15 materials or remove galley cooking equipment from service.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 November 2019
Resolved 18 October 2019
Resolution: Installed approved class B-15 material
08 - Alarms › N/A - No Subsystem › Emergency signal
Issued 18 July 2019 Resolved
Demonstrate the operational readiness of high water alarm in the tank and laz spaces
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 18 July 2019
Resolved 18 July 2019
Resolution: O/O effected permanent reapir in presence of MI
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 18 July 2019 Resolved
Replace netting in life floats on top of bridge
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 August 2019
Resolved 13 August 2019
Resolution: O/O conducted permanenet repairs
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 July 2019 Resolved
Properly secure/remove from service dead end wiring and permanently mount DC bus as directed
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 August 2019
Resolved 13 August 2019
Resolution: O/O proper secured DC wiring below nav. station
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 13 September 2018 Resolved
Vsl is broadcasting greater than expected vessel length
Condition: Invalid
Action required: 705 - Other - as specified
Due 18 November 2018
Resolved 27 June 2019
Resolution: Verified CG NAVCEN VIVS, no AIS deficiencies pending per website.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 2 May 2017 Resolved
Conduct MOB with USCG in attendance.
Action required: 705 - Other - as specified
Due 16 May 2017
Resolved 10 May 2017
Resolution: Conducted satisfactory Drills.
Lifesaving › Lifefloat › Paddle
Issued 5 July 2016 Resolved
Replace paddle on aft lifefloat.
Action required: 705 - Other - as specified
Due 19 July 2016
Resolved 19 July 2016
Resolution: MI attended vessel and witnessed a new paddle had been put in aft life float.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 5 July 2016 Resolved
Re-label 3 lifebuoys.
Action required: 705 - Other - as specified
Due 19 July 2016
Resolved 19 July 2016
Resolution: MI attended vessel and witnessed the life buoys had been relabeled
Communications › Radio Communications › Radiotelephone Transceiver (2-27.5 MHz)
Issued 5 July 2016 Resolved
Post emergency broadcast placard.
Due 19 July 2016
Resolved 19 July 2016
Resolution: MI attended vessel and witnessed correction
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 5 July 2016 Resolved
Log all MOB and Fire Drills
Action required: 705 - Other - as specified
Due 6 July 2016
Resolved 19 July 2016
Resolution: MI attended vessel and witnessed log entries
Communications › Alarms/Indicators › Bilge Alarm
Issued 5 July 2016 Resolved
Re-label all bilge alarms.
Action required: 705 - Other - as specified
Due 19 July 2016
Resolved 19 July 2016
Resolution: MI attended vessel and witnessed proper operation of alarm
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 5 July 2016 Resolved
Replace all expired floatlight batteries.
Action required: 705 - Other - as specified
Due 19 July 2016
Resolved 19 July 2016
Resolution: MI attended vessel and witnessed correction
Engineering › Generator (propulsion-electric) › Conductor
Issued 5 July 2016 Resolved
Replace/renew lagging on stbd engine/generator.
Action required: 705 - Other - as specified
Due 19 July 2016
Resolved 19 July 2016
Resolution: MI attended vessel and witnessed repair of lagging
Navigation › Collision/Grounding Avoidance › Navigation Bridge Visibility
Issued 17 June 2014 Resolved
Replace cracked windows at next dry dock.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 21 January 2015
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 17 June 2014 Resolved
Replace retro on lifejackets as necessary and begin a monthly retro reflective inspection program.
Condition: Improper/Lack of Maintenance
Due 30 June 2014
Resolved 30 June 2014
Resolution: completed
Lifesaving › Lifefloat › Paddle
Issued 17 June 2014 Resolved
Replace paddles
Condition: Improper/Lack of Maintenance
Due 30 June 2014
Resolved 30 June 2014
Resolution: paddles were replaced
Communications › Radio Communications › EPIRB
Issued 17 June 2014 Resolved
Replace battery
Condition: Placed in Improper Service
Due 17 June 2014
Resolved 23 June 2014
Resolution: replaced
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 16 May 2012 Resolved
One CO2 BII fire extinguisher is missing the "tamper seal" Insure extinguisher is ready for service & a new tamper seal fitted.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 May 2012
Resolved 23 May 2012
Resolution: Recieved photo copy of service.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 16 May 2012 Resolved
One dry chemical BII fire extinguisher is missing the "tamper seal" Insure extinguisher is ready for service & a new tamper seal fitted.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 May 2012
Resolved 23 May 2012
Resolution: Recieved photo copy of service
Engineering › Bilge Water Management System › Valve
Issued 16 May 2012 Resolved
Mark bilge manifold valves.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 May 2012
Resolved 16 May 2012
Resolution: Corrected date of exam.
Construction/Loadline › Structures › Superstructure
Issued 16 May 2012 Resolved
Replace broken window glass.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 May 2012
Resolved 21 May 2012
Resolution: Replace by Otto Glass from Wainscott, NY
Electrical › Electric Supply System (service) › Battery Installation
Issued 16 May 2012 Resolved
Provide an acid resistant battery tray or box and protection for the voltage output connection for the 12 VDC battery on the stbd side aft of E/R.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 May 2012
Resolved 18 May 2012
Resolution: Work completed by crew. Photo provided of new box installed.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 16 May 2012 Resolved
Provide employee assistance program posting per 46CFR16.401.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 May 2012
Resolution: Postings made date of exam.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 16 May 2012 Resolved
Provide Alcohol testing equipment for use aboard the vessels for use in the event of a need to conduct post incident testing. (see 46 CFR 16.240)
Action required: 705 - Other - as specified
Due 30 May 2012
Resolved 25 May 2012
Resolution: Provided via Drug Consortium supplier
Navigation › Piloting/Steering › Local Notices to Mariners
Issued 16 May 2012 Resolved
Provide updated charts for the operating area. See 46 CFR 184.420
Action required: 705 - Other - as specified
Due 18 May 2012
Resolved 18 May 2012
Resolution: Updated via e-purchase of new chart & NTM.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 15 May 2012 Resolved
Complete satisfactory COI inspection prior to carrying passengers for hire.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 May 2012
Resolution: Satisfactory COI inspection completed on 16MAY12 and the TCOI was issued 29MAY12.
Engineering › Steering Gear System › Ram
Issued 29 November 2010 Resolved
Provide proof of proper re-installation of steering gear.
Action required: 705 - Other - as specified
Due 30 December 2010
Resolved 23 December 2010
Resolution: Pictures of system e-mailed.
Communications › Alarms/Indicators › Bilge Alarm
Issued 1 July 2009 Resolved
Label alarm panel on bridge.
Condition: Placed in Improper Service
Due 10 July 2009
Resolved 23 July 2009
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 1 July 2009 Resolved
replace retro reflective tape on L/J's as needed
Condition: Improper/Lack of Maintenance
Due 15 July 2009
Resolved 23 July 2009
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 1 July 2009 Resolved
Replace 4 adult L/J's that were rejected, passenger count is reduced by 4 until L/J's are replaced
Condition: Placed in Improper Service
Due 15 July 2009
Resolved 23 July 2009
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 1 July 2009 Resolved
Label breaker panel on bridge.
Condition: Placed in Improper Service
Due 10 July 2009
Resolved 23 July 2009
Lifesaving › Visual Distress Signals (General) › Storage
Issued 1 July 2009 Resolved
Secure waterlight to L/F prior to carrying passengers. corrected on the spot
Condition: Placed in Improper Service
Due 1 July 2009
Resolved 1 July 2009
Stability › Weathertight Integrity › General
Issued 25 November 2008 Resolved
Replace 2 cracked windows as discussed with Coast Guard Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 December 2008
Resolved 8 December 2008
Resolution: Received email with pictures attached showing the cracked windows had been replaced. Cleared 835 requirement
Lifesaving › Lifefloat › Netting
Issued 10 April 2008 Resolved
Repair basket on life float. NMT 60 persons permitted aboard vessel until L/F satisfactorily repaired or replaced.
Action required: 705 - Other - as specified
Due 30 April 2008
Resolved 24 April 2008
Resolution: Replaced worn wood botom of drop basket.
Lifesaving › Lifefloat › Painter
Issued 10 April 2008 Resolved
Replace yellow 100' sea painter for L/F with the proper size dark color U/V resistant 100' sea painter. (See 46 CFR 175 (f)(3).
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 April 2008
Resolved 24 April 2008
Resolution: Replaced.
Engineering › Pressure Vessel › Foundation
Issued 10 April 2008 Resolved
Install permanent brackets & foundation for the electric hot water heater used for the hand rail heat system.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 April 2008
Resolved 24 April 2008
Resolution: Electric hot water heater permanently removed from vessel. Inspection note added.
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 10 April 2008 Resolved
Install permanent brackets for water piping and fuel piping IWO Main engines. (Wire, ropes, wire ties, pieces of 2X4, etc. are not adequate securing systems.) Flexible piping need to be adequately supported too. Examine your E/R and remove the jury rigs and replace with substantial piping supports at intervals necessary to prevent excessive motion.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 May 2008
Resolved 24 April 2008
Resolution: Metal pipe brackets fabricated & installed to hold piping secure.
Construction/Loadline › Penetrations › Valve Flange
Issued 10 April 2008 Resolved
Install valves at water tight bhds where non-metallic piping is used. All non-metallic pipes that pass thru a bhd must have a metal spoolpiece w/ a shut off valve before the connection of the non-metallic piping. {see 46CFR182.720(d)(1). This is important information about valve requirements. READ IT.}
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 April 2008
Resolved 24 April 2008
Resolution: Galvanized steel nipples w/ brass stop valves fitted at Bhd penetrations & then PVC piping reattached.
Operations/Management › Drills/Instruction › Abandon Ship
Issued 11 April 2007 Resolved
Conduct Man Overboard and fire drill prior to sailing.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 May 2007
Resolution: Vessel conducted man overboard and fire drill on 19 Apr 07 at 12:15pm outside Montauk harbor with two crewmembers and one captain. The fire drill was simulated as a bunkroom fire.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 11 April 2007 Resolved
Repair broken bridge window.
Due 1 May 2007
Resolved 1 May 2007
Resolution: Broken window was removed and safety glass was replaced by local glass shop.
Lifesaving › Lifefloat › Serviceable
Issued 11 April 2007 Resolved
Overhaul lifefloats providing new lines where necessary, and removing all trash and debris from arrangement prior to sail.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 May 2007
Resolution: All liferafts were removed from their cradle and the area and rafts were cleaned of all trash. Painter and several lifelines were replaced as the old lines were rotted.
Lifesaving › Lifebuoys › Serviceable
Issued 11 April 2007 Resolved
Provide three new ring buoys prior to sail.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 May 2007
Resolution: Purchased three new liferings, and new painter lines and water light was attached as necessary.
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 11 April 2007 Resolved
Provide copy of CG Nav rules on vessel.
Due 20 April 2007
Resolved 15 April 2007
Resolution: Placed copy of Coast Guard Nav Rules on bridge with the rest of vessels publications.
Accommodation/Occupational Safety › Other Accommodation Spaces › Insect Screen
Issued 5 April 2006 Resolved
Replace two crked windows in accomodation space.
Due 25 May 2006
Resolved 24 May 2006
Electrical › Electric Supply System (service) › Cable
Issued 5 April 2006 Resolved
Remove dead end wires from the pilot house consul.
Due 25 May 2006
Resolved 24 May 2006
Electrical › Lighting (service) › Lighting Fixture
Issued 5 April 2006 Resolved
Provide cages for all lighting fixtures in engine room.
Due 24 May 2006
Resolved 25 May 2006
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 11 April 2005 Resolved
Replace 19 lifejacket lights prior to 18 April 05.
Due 18 April 2005
Resolved 13 April 2005
Resolution: Per ltr fm O/O, ltr scanned into documents for this activity.
Deck/Cargo › Mooring/Anchoring › Capstan
Issued 11 April 2005 Resolved
Properly secure anchor windlass hydraulic lines to overhead in collision compartment prior to 11 May 05.
Due 11 May 2005
Resolved 15 April 2005
Resolution: Per ltr fm O/O, ltr scanned into documents for this activity.
Communications › Radio Communications
Issued 15 April 2004 Resolved
EPIRB is not operating properly under test, until repaired or replaced vessel is limited to no more than 3 miles on a coastwise route. LEGACY COMPONENT DESC: EPIRB
Due 15 May 2004
Resolved 14 May 2004
Accommodation/Occupational Safety › Occupational Safety
Issued 15 April 2004 Resolved
Replace (4) cracked windows in the pilothouse. LEGACY COMPONENT DESC: Windows
Due 15 May 2004
Resolved 14 May 2004
Accommodation/Occupational Safety › Heating
Issued 15 April 2004 Resolved
Secure hot water heater in the engine room with permanent fixtures. LEGACY COMPONENT DESC: Hot water heater
Due 15 May 2004
Resolved 14 May 2004
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 23 April 2002 Resolved
REPLACE/SERVICE B-1 FIRE EXTINGUISHER ON BRIDGE.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 May 2002
Resolved 1 May 2002
Fire Fighting › Fire Pumps › Pressure
Issued 23 April 2002 Resolved
REPAIR/REPLACE FIRE PUMP. PRESSURE PROVIDED IS INSUFFICIENT.
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 May 2002
Resolved 1 May 2002
Fire Fighting › Fire Pumps › Arrangement
Issued 23 April 2002 Resolved
PROVIDE AND POST INSTRUCTIONS FOR OPERATION OF THE FIRE PUMP.
Due 23 May 2002
Resolved 1 May 2002
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 23 April 2002 Resolved
PROVIDE CURRENT NAVIGATION CHARTS, TIDE & TIDAL CURRENT TABLES, AND LIGHT LIST.
Due 23 May 2002
Resolved 1 May 2002
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 23 April 2002 Resolved
LABEL LIFE JACKET BOXES WITH QUANTITY, AND PROVIDE PARTITION FOR CHILD LIFEJACKETS.
Due 23 May 2002
Resolved 1 May 2002
Lifesaving › Rigid Liferafts
Issued 23 April 2002 Resolved
PROVIDE NEW PAINTER FOR LIFE FLOATS. LEGACY COMPONENT DESC: Painter
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 May 2002
Resolved 1 May 2002
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 23 April 2002 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Due 23 May 2002
Resolved 1 May 2002
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 23 April 2002 Resolved
PROVIDE NON CONDUCTIVE MAT IN FRONT OF SWITCHBOARD.
Due 23 May 2002
Resolved 1 May 2002
Engineering › Fuel Oil Service System › Gauge
Issued 23 April 2002 Resolved
PROVIDE CLAMP FOR FUEL SIGHT HOSE.
Due 23 May 2002
Resolved 1 May 2002
Lifesaving › Rigid Liferafts › Weak Link
Issued 23 April 2002 Resolved
PROVIDE NEW WEAK LINKS FOR LIFE FLOATS.
Due 23 May 2002
Resolved 1 May 2002
Fire Fighting
Issued 26 June 2001 Resolved
REPLACE FIRE PUMP PRESSURE GUAGE, INSTALL AT DISCHARGE SIDE AND PROVE PROPER FIRE MAIN PRESSURE.
Condition: Unknown
Due 10 July 2001
Resolved 1 May 2002
Resolution: REQUIREMENT CLEARED, AND REISSUED AFTER COI INSPECTION ON 24APR02.
Fire Fighting
Issued 26 June 2001 Resolved
PRIOR TO CARRIAGE OF PASSENGERS, INSTALL FALME SCREEN IN SEWAGE VENT.
Condition: Unknown
Due 26 July 2001
Resolved 1 May 2002
Fire Fighting
Issued 26 June 2001 Resolved
INSTALL MINIMUM B-15 INSULATION IN VICINITY OF OPEN RANGE OR PROVIDE PROOF OF STRUCTURAL FIRE PROTECTION TO THE SATISFACTION OF THE COGNIZANT OCMI_x001C_ PRIOR TO USE.
Condition: Unknown
Due 26 June 2001
Resolved 24 April 2002
Lifesaving
Issued 26 June 2001 Resolved
UPON ARRIVAL TO HOMEPORT, NOTIFY LOCAL OCMI FOR DETERMINATION ON ENFORCEMENT OF NEW LIFESAVING REQUIREMENTS IAW 46CFR180.200.
Condition: Unknown
Due 26 July 2001
Resolved 24 April 2002
Resolution: REQUIREMENT NOT CLEARED UNTIL COI EXAM OF 24APR02.
Lifesaving
Issued 26 June 2001 Resolved
UPON ARRIVAL TO HOMEPORT, CONDUCT DRILLS IAW LOCAL [name withheld].
Condition: Unknown
Due 26 July 2001
Resolved 24 April 2002
Resolution: REQUIREMENT NOT CLEARED UNTIL COI EXAM OF 24APR02.
Documentation
Issued 26 June 2001 Resolved
PROVIDE FCC STATION LICENSE.
Condition: Unknown
Due 26 July 2001
Resolved 1 May 2002
Documentation
Issued 26 June 2001 Resolved
PROVIDE PROOF OF 406 MHZ EPIRB REGISTRATION..
Condition: Unknown
Due 26 July 2001
Resolved 1 May 2002
Engineering
Issued 22 March 2001 Resolved
REPLACE PORT FUEL TANK FLANGE GASKET.
Condition: Unknown
Due 22 March 2001
Resolved 22 March 2001
Construction/Loadline
Issued 22 March 2001 Resolved
UPON SPLASHING OF VESSEL, MAKE HULL AVAILABLE FOR FINAL INSPECTION.
Condition: Unknown
Due 11 April 2001
Resolved 11 April 2001
Electrical
Issued 20 March 2000 Resolved
REPLACE WORN/HOLED AIR INTAKE GUARD ON THE PORT SSGEN SET DIESEL.
Condition: Unknown
Due 18 April 2000
Resolved 18 April 2000
Electrical
Issued 20 March 2000 Resolved
REINSTALL MISSING GUARD FOR AIR COOLING FAN ON STBD SSGEN SET.
Condition: Unknown
Due 18 April 2000
Resolved 18 April 2000
Accommodation/Occupational Safety
Issued 20 March 2000 Resolved
REPAIR BROKEN WINDOW IN MAIN PASSENGER CABIN.
Condition: Unknown
Due 31 March 2000
Resolved 18 April 2000
Electrical
Issued 21 January 1999 Resolved
PROVIDE ADEQUATE BRACKET OR GUARD TO PREVENT CHAFING ON COOLANT LINE ON PORT SERVICE GENERATOR.
Condition: Unknown
Due 22 February 1999
Resolved 22 February 1999
Engineering
Issued 21 January 1999 Resolved
LABEL FUEL SHUT OFF VALVES
Condition: Unknown
Due 22 February 1999
Resolved 22 February 1999
Electrical
Issued 21 January 1999 Resolved
SECURE WIRING CONDUIT AT ENTRANCE WAY TO E.R. TO THE BHD.
Condition: Unknown
Due 22 February 1999
Resolved 22 February 1999
Construction/Loadline
Issued 21 January 1999 Resolved
AT NEXT DRYDOCKING GAGE PORT BOTTOM IWO AREA BELOW ENTRANCE LADDER TO ENGINE ROOM AND RENEW ASSOCIATED INTERNALS AS REQUIRED BY THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 21 January 1999
Resolved 21 January 1999
Lifesaving
Issued 21 January 1999 Resolved
CONDUCT SATISFACTORY MAN OVERBOARD, FIRE, AND ABANDON SHIP DRILLS IN THE PRESENCE OF A CG MARINE INSPECTOR.
Condition: Unknown
Due 22 February 1999
Resolved 22 February 1999
Electrical
Issued 21 January 1999 Resolved
ON PORT IC ENGINE REPLACE TWIST TYPE WIRE CONNECTORS WITH CRIMP TYPE.
Condition: Unknown
Due 22 February 1999
Resolved 22 February 1999
Electrical
Issued 21 January 1999 Resolved
PORT & STBD SHIPS SERVICE GENERATORS ARE MISSING LAGGINGS FOR EXPOSED PIPES.
Condition: Unknown
Due 22 February 1999
Resolved 22 February 1999
Engineering
Issued 21 January 1999 Resolved
LAGGINGS FOR EXHAUST PIPES ARE MISSING ON PORT AND STBD IC ENGINES
Condition: Unknown
Due 22 February 1999
Resolved 22 February 1999
Accommodation/Occupational Safety
Issued 21 January 1999 Resolved
REPLACE BROKEN WINDOWS IN DECKHOUSE AND PILOT HOUSE.
Condition: Unknown
Due 22 February 1999
Resolved 22 February 1999
Electrical
Issued 21 January 1999 Resolved
GUARD NEEDED FOR BELT ON STBD SIDE GENERATOR.
Condition: Unknown
Due 3 March 1999
Resolved 3 March 1999
Construction/Loadline
Issued 13 January 1998 Resolved
CROP OUT HULL DOUBLER PLATE ON PORT SIDE ADJACENT TO FORWARD ENG ROOM BULKHEAD AND WELD INSERT SAME AS ORIG HULL THICKNESS. INSERT TO BE EXAMINEDAND TESTED TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 13 January 1998
Resolved 14 January 1998
Lifesaving
Issued 13 January 1998 Resolved
PROVIDE A RUNG OR FOOTHOLD TO THE EMERGENCY ESCAPE FROM FORWARD BERTHING.
Condition: Unknown
Due 13 January 1998
Resolved 14 January 1998
Construction/Loadline
Issued 13 January 1998 Resolved
LOWER BILGE ALARM FLOAT SWITCHES TO ENABLE EFFECTIVE OPERATION.
Condition: Unknown
Due 13 January 1998
Resolved 14 January 1998
Construction/Loadline
Issued 13 January 1998 Resolved
REPLACE 2 MSD SEA VALVES.
Condition: Unknown
Due 13 January 1998
Resolved 14 January 1998
Lifesaving
Issued 18 April 1997 Resolved
PROVIDE RENEWED PFD LIGHTS.
Condition: Unknown
Due 28 August 1997
Resolved 28 August 1997
Construction/Loadline
Issued 18 April 1997 Resolved
PROVIDE A BILGE HIGH WATER ALARM FOR ALL COMPARTMENTS WHERE THERE ARE THROUGH HULL FITTINGS. SEE 46CFR 182.530 NEW REGS.
Condition: Unknown
Due 18 April 1997
Resolved 18 April 1997
Documentation
Issued 18 April 1997 Resolved
PROVIDE A REPLACEMENT FOR THE WEATHER WORN CERTIFICATE OF DOCUMENTATION.
Condition: Unknown
Due 1 August 1997
Resolved 1 August 1997
Navigation
Issued 18 April 1997 Resolved
PROVIDE NAVIGATION LIGHTS WHICH MEET THE STANDARD "UL 1104".
Condition: Unknown
Due 18 April 1997
Resolved 18 April 1997
Unknown
Issued 18 April 1997 Resolved
RENEW PRESSURE RELIEF VALVE ON HOT WATER HEATER.
Condition: Unknown
Due 1 August 1997
Resolved 1 August 1997
Fire Fighting
Issued 18 April 1997 Resolved
PROVIDE PROOF OF MONTHLY INSPECTION OF PORTABLE FIRE EXTINGUISHERS BY A PERSON IN CHARGE. (NOTE: NOTATION ON THE TAG ATTATCHED TO THE EXTINGUISHEROR A LOG ENTRY IS ADEQUATE.)
Condition: Unknown
Due 1 August 1997
Resolved 1 August 1997
Unknown
Issued 18 April 1997 Resolved
PROVIDE A "DOT APPROVED" FIRST AID KIT OR EQUVALENT.
Condition: Unknown
Due 1 August 1997
Resolved 1 August 1997
Electrical
Issued 18 April 1997 Resolved
PROVIDE COVERS OVER BATTERIES.
Condition: Unknown
Due 1 August 1997
Resolved 1 August 1997
Construction/Loadline
Issued 17 April 1996 Resolved
RENEW DECK HATCH GASKETS.
Condition: Unknown
Due 19 May 1996
Resolved 7 August 1996
Lifesaving
Issued 17 April 1996 Resolved
REPAIR PFD STORAGE BOX COVERS.
Condition: Unknown
Due 19 May 1996
Resolved 7 August 1996
Navigation
Issued 17 April 1996 Resolved
LUBRICATE ALL STEERING GEAR FITTINGS.
Condition: Unknown
Due 19 May 1996
Resolved 7 August 1996
Construction/Loadline
Issued 17 April 1996 Resolved
CLOSE STUFFING TUBE IN AFT BHD.
Condition: Unknown
Due 19 May 1996
Resolved 7 August 1996
Construction/Loadline
Issued 17 April 1996 Resolved
CLOSE STUFFING TUBES IN FWD BHD OF BUNK ROOM BELOW MAIN DECK.
Condition: Unknown
Due 19 May 1996
Resolved 7 August 1996
Accommodation/Occupational Safety
Issued 17 April 1996 Resolved
REPLACE BROKEN WINDOW IN MAIN DECK HOUSE.
Condition: Unknown
Due 19 May 1996
Resolved 7 August 1996
Lifesaving
Issued 17 April 1996 Resolved
RENEW REFLECTOR TAPE ON 22 ADULT PFDS. VESSEL RESTRICTED TO 128 MAX PERSONS UNTIL THIS REQUIREMENT IS CLEARED.
Condition: Unknown
Due 19 May 1996
Resolved 7 August 1996
Electrical
Issued 17 April 1996 Resolved
RENEW GAGE PANEL ON MAIN SWITCH BOARD.
Condition: Unknown
Due 19 May 1996
Resolved 7 August 1996
Engineering
Issued 17 April 1996 Resolved
MAKE PERMANENT REPAIR TO THE EXHAUST PIPE FOR THE PORT DIESEL GENERATOR.
Condition: Unknown
Due 19 May 1996
Resolved 7 August 1996
Lifesaving
Issued 17 April 1996 Resolved
INSTALL REFLECTOR TAPE ON 2 RING BUOYS.
Condition: Unknown
Due 19 May 1996
Resolved 7 August 1996
Engineering
Issued 17 April 1996 Resolved
MAKE PERMANENT REPAIR TO CLUTCH CONTROL CABLE FITTING (RENEW BALL JOINT) ONPORT ENGINE.
Condition: Unknown
Due 19 May 1996
Resolved 7 August 1996
Engineering
Issued 17 April 1996 Resolved
REPAIR OIL PRESSURE GAGE FOR PORT ENGINE.
Condition: Unknown
Due 19 May 1996
Resolved 7 August 1996
Navigation
Issued 17 April 1996 Resolved
PERMANENTLY MOUNT RADIOS.
Condition: Unknown
Due 19 May 1996
Resolved 7 August 1996
Lifesaving
Issued 24 March 1994 Resolved
PROVIDE 2 ADULT LIFEJACKETS. VESSEL IS RESTRICTED TO 148 TOTAL PERSONS UNTIL JACKETS PROVIDED.
Condition: Unknown
Due 15 April 1994
Resolved 15 April 1994
Lifesaving
Issued 24 March 1994 Resolved
PROVIDE EMERGENCY LIGHTING FOR BELOW MAIN DECK PASSENGER ACCOMMODATION IAW 46CFR184,30-5. PASSENGERS ARE NOT PERMITTED TO USE THIS AREA UNTIL REQ'T IS COMPLETED.
Condition: Unknown
Due 15 April 1994
Resolved 15 April 1994
Electrical
Issued 24 March 1994 Resolved
PROPERLY LABEL ALL SWITCHES, CONTROL BOXES, AND SWITCHBOARD IN ENGINE_x001C_ ROOM.
Condition: Unknown
Due 24 March 1994
Resolved 24 March 1994
Electrical
Issued 24 March 1994 Resolved
PROVIDE A PRESSURE GAUGE FOR FIRE PUMP.
Condition: Unknown
Due 24 March 1994
Resolved 24 March 1994
Lifesaving
Issued 24 March 1994 Resolved
PROVIDE SUITABLE LADDER AND/OR STEPS FOR SECOND MEANS OF ESCAPE FROM BELOW DECK PASSENGER ACCOMODATION. PASSENGERS ARE NOT PERMITTED TO USE THIS AREAUNTIL REQ'T IS COMPLETED.
Condition: Unknown
Due 24 March 1994
Resolved 24 March 1994
Construction/Loadline
Issued 20 May 1992 Resolved
RENEW IN KIND THE STERN TUBE SUPPORT FRAMES ON THE PORT AND STARBOARD STERN TUBES LOCATED IN THE ENGINEROOM.
Condition: Unknown
Due 20 May 1992
Resolved 20 May 1992
Construction/Loadline
Issued 20 May 1992 Resolved
RENEW IN KIND APPROXIMATELY EIGHTEEN (18) INCHES OF UNDER DECK FRAMING ON THE PORT SIDE OF THE DECK HATCH LOCATED IN THE FORE PEAK.
Condition: Unknown
Due 20 May 1992
Resolved 20 May 1992
Navigation
Issued 6 January 1992 Resolved
REPLACED STERN LIGHT BULB. PROVIDED SPARES ABOARD VESSEL.
Condition: Unknown
Due 5 February 1992
Resolved 5 February 1992
Fire Fighting
Issued 6 January 1992 Resolved
RECHARGE AND HYDRO TEST 1 BII CO2.
Condition: Unknown
Due 5 February 1992
Resolved 5 February 1992
Electrical
Issued 6 January 1992 Resolved
INSTALL BLANKS OVER UNUSED SECTIONS OF ELECTRIC BREAKER PANELS AND SECURE PANEL COVERS TO BOXESF.
Condition: Unknown
Due 6 January 1992
Resolved 6 January 1992
Accommodation/Occupational Safety
Issued 6 January 1992 Resolved
REPAIR BROKEN WINDOWS.
Condition: Unknown
Due 6 January 1992
Resolved 6 January 1992
Fire Fighting
Issued 6 January 1992 Resolved
ADD 1 BII FIRE EXTINGUISHER FOR GALLEY.
Condition: Unknown
Due 5 February 1992
Resolved 5 February 1992
Electrical
Issued 6 January 1992 Resolved
REPLACE MISSING GUARDS ON LIGHTING FIXTURES IN MACHINERY SPACES.
Condition: Unknown
Due 5 February 1992
Resolved 5 February 1992
Electrical
Issued 6 January 1992 Resolved
RENEWED TEMPORARY LIGHTING FROM MACHINERY SPACES.
Condition: Unknown
Due 5 February 1992
Resolved 5 February 1992
Lifesaving
Issued 6 January 1992 Resolved
CLEANED AND REPAINTED WORN RING BUOY.
Condition: Unknown
Due 5 February 1992
Resolved 5 February 1992
Lifesaving
Issued 6 January 1992 Resolved
RENEWED WATER LIGHT BATTERY.
Condition: Unknown
Due 5 February 1992
Resolved 5 February 1992
Lifesaving
Issued 6 January 1992 Resolved
RENEWED REFLECTOR TAPE ON 2 CHILD PFD'S.
Condition: Unknown
Due 5 February 1992
Resolved 5 February 1992
Construction/Loadline
Issued 2 July 1991 Resolved
REPLACE SCUTTLES IN #5 COMPT (BY HEAD) AND LAZARETTE.
Condition: Unknown
Due 2 July 1991
Resolved 2 July 1991
Construction/Loadline
Issued 2 July 1991 Resolved
RENEW WASTED UNDERDECK FRAMES BY LAZARETTE SCUTTLE.
Condition: Unknown
Due 2 July 1991
Resolved 2 July 1991
Construction/Loadline
Issued 2 July 1991 Resolved
BLANK OFF OR REMOVE UNSED MAIN ENGINE KEEL COOLER LINES INBOARD OF MAIN ENGINES.
Condition: Unknown
Due 2 July 1991
Resolved 2 July 1991
Lifesaving
Issued 3 January 1990 Resolved
RENEW LIFE LINE AROUND RING BUOYS WHERE SUN DAMAGED.
Condition: Unknown
Due 3 January 1990
Resolved 3 January 1990
Lifesaving
Issued 3 January 1990 Resolved
RENEWED SUN DAMAGED PENDANTS ON BUOYANT APPARATUS.
Condition: Unknown
Due 3 January 1990
Resolved 3 January 1990
Lifesaving
Issued 3 January 1990 Resolved
REMOVE OR REARRANGE HASPS ON PFD STORAGE SO THAT BOXES CAN NOT LOCK INADVERTENTLY PREVENTING THE PFD'S FROM FLOATING FREE.
Condition: Unknown
Due 3 January 1990
Resolved 3 January 1990
Engineering
Issued 3 January 1990 Resolved
RENEWED FLAME SCREENS AND BALL CHECKS ON FUEL TANK VENTS.
Condition: Unknown
Due 3 January 1990
Resolved 3 January 1990
Lifesaving
Issued 3 January 1990 Resolved
RETAPED 5 ADULT & 4 CHILD PFDS
Condition: Unknown
Due 3 January 1990
Resolved 3 January 1990
Fire Fighting
Issued 3 January 1990 Resolved
HYDRO TEST THE BII CO2 EXTINGUISHERS W/DATES 5 YEARS OR OLDER.
Condition: Unknown
Due 3 January 1990
Resolved 3 January 1990
Lifesaving
Issued 3 January 1990 Resolved
RESECURE SEA PAINTER FOR LIFE FLOATS W/WEAK LINK.
Condition: Unknown
Due 3 January 1990
Resolved 3 January 1990
Construction/Loadline
Issued 2 February 1989 Resolved
FREE DOGS ON AFT HATCH.
Condition: Unknown
Due 2 February 1989
Resolved 2 February 1989
Lifesaving
Issued 2 February 1989 Resolved
PROVIDE WATERLIGHTS FOR ALL LIFE PRESERVERS.
Condition: Unknown
Due 2 February 1989
Resolved 2 February 1989
Navigation
Issued 2 February 1989 Resolved
PROVIDE DAY SHAPE FOR ANCHORING.
Condition: Unknown
Due 2 February 1989
Resolved 2 February 1989
Navigation
Issued 2 February 1989 Resolved
REPAIR MASTHEAD AND STERN LIGHT WINGS.
Condition: Unknown
Due 2 February 1989
Resolved 2 February 1989
Engineering
Issued 2 February 1989 Resolved
REMOVE CLEAR PLASTIC SIGHT GAGE FROM FUEL SYSTEM.
Condition: Unknown
Due 2 February 1989
Resolved 2 February 1989
Electrical
Issued 15 April 1987 Resolved
REPAIR DECK LIGHT JUNCTION BOXES.
Condition: Unknown
Due 15 April 1987
Resolved 15 April 1987
Documentation
Issued 15 April 1987 Resolved
PROVIDE FCC SAFETY CERTIFICATE.
Condition: Unknown
Due 15 April 1987
Resolved 15 April 1987
Navigation
Issued 15 April 1987 Resolved
MOVE MASTHEAD LIGHT FORWARD OF SIDE LIGHTS.
Condition: Unknown
Due 15 April 1987
Resolved 15 April 1987
Navigation
Issued 15 April 1987 Resolved
PROVE OPERATION OF EPRIB.
Condition: Unknown
Due 15 April 1987
Resolved 15 April 1987
Construction/Loadline
Issued 15 April 1987 Resolved
REPAIR OR REPLACE HATCH TO STEERING SPACE AND PROVIDE SECURING CHAINS FOR ALL WEATHER DECK HATCHES.
Condition: Unknown
Due 15 April 1987
Resolved 15 April 1987
Lifesaving
Issued 15 April 1987 Resolved
REPLACE FRAYED AND SUN DRIED LIFE LINES ON BUOYANT APPARATUS.
Condition: Unknown
Due 15 April 1987
Resolved 15 April 1987
Lifesaving
Issued 15 April 1987 Resolved
REPLACE RUSTED FLOAT FREE WEAK LINKS (2) AND ONE 100' SEA PAINTER ON BUOYANT APPARATUS.
Condition: Unknown
Due 15 April 1987
Resolved 15 April 1987
Fire Fighting
Issued 15 April 1987 Resolved
REPAIR STBD FIRE HYDRANT/VALVE STUCK OPEN.
Condition: Unknown
Due 15 April 1987
Resolved 15 April 1987
Engineering
Issued 15 April 1987 Resolved
PROVIDE 30 X 30 MEST FLAME SCREENS ON FUEL TANK VENTS.
Condition: Unknown
Due 15 April 1987
Resolved 15 April 1987
Electrical
Issued 15 April 1987 Resolved
PROVE OPERATION OF 20 KW AUX. GENERATOR.
Condition: Unknown
Due 15 April 1987
Resolved 15 April 1987

Casualty record · 2

12 August 2010Routine · role: Involved in a Marine Casualty · 1 injured · activity 3834025
4 October 2020Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 7071264
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record