Records from 1985 to 2002. Most recent: inspection, 25 November 2002.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 36
25 November 2002
Hull Examination · Construction Oversight
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 1710250
19 June 2002
COI Inspection · Deficiency Check
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 1632808
16 April 2002
Hull Examination · Periodic Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1605681
31 October 2001
Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1077284
18 April 2001
Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1062308
20 March 2001
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1373428
28 April 2000
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1453770
29 April 1999
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1131762
8 April 1999
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1123947
31 March 1999
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1124062
12 January 1999
Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 810052
23 June 1998
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1131560
16 April 1998
Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1123116
30 March 1998
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 139087
8 May 1997
COI Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1383577
21 May 1996
Re-Inspection · Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1383257
12 March 1996
Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 886309
2 May 1995
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1417776
26 April 1994
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 862112
22 April 1994
Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1423915
4 May 1993
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1397909
1 September 1992
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 957055
20 May 1992
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1264183
10 April 1992
Drydock Extension
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 943002
1 May 1991
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 929092
24 April 1991
Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 929090
19 November 1990
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1211564
2 May 1990
Deficiency Check · Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 920391
19 March 1990
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1220170
14 April 1989
Hull Examination · Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1202121
1 June 1988
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1350170
4 May 1988
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 898587
22 October 1987
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1325348
5 May 1987
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1005721
21 April 1986
Credit Drydock · Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1308770
14 May 1985
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1291761
Fire Fighting › Fire Pumps › Power Source
Issued 19 June 2002
Resolved
MAKE FIRE PUMP OPERATIONAL AND PROVE PROPER OPERATION.
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 June 2002
Resolved 20 June 2002
Resolution: JABSCO PUMP ON STBD ENGINE MADE OPERATIONAL AND ELECTRIC WILL BE REPAIRED WHEN NEW GENERATOR IS INSTALLED.
Fire Fighting › Fixed Fire Detection System
Issued 19 June 2002
Resolved
PROVE PROPER OPERATION OF FIRE DETECTION SYSTEM.
Action required: 705 - Other - as specified
Due 3 July 2002
Resolved 24 July 2002
Resolution: SYSTEM TESTED SAT.
Fire Fighting › Fire Pumps
Issued 19 June 2002
Resolved
PROVE PROPER OPERATION OF ELECTRIC FIRE PUMP. LEGACY COMPONENT DESC: Power Source
Action required: 705 - Other - as specified
Due 3 July 2002
Resolved 24 July 2002
Resolution: FIRE PUMP TESTED SAT.
Lifesaving › Buoyant Apparatus
Issued 19 June 2002
Resolved
INSTALL WEAK LINKS PAINTERS AND EQUIPMENT ON ALL LIFE FLOATS AND BOUYANT APPARATUS AS REQUIRED. LEGACY COMPONENT DESC: EQUIPMENT
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 June 2002
Resolved 20 June 2002
Resolution: ALL EQUIPMENT INSTALLED.
Communications › Radio Communications › EPIRB
Issued 19 June 2002
Resolved
REPALCE EPIRB HYDROSTATIC RELEASE AND PROVE CURRENT REGISTRATION WITH NOAA.
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 June 2002
Resolved 20 June 2002
Resolution: RELEASE REPLACED AND REGISTRATION SENT TO NOAA.
Electrical › Electric Generation Source (service)
Issued 19 June 2002
Resolved
PROVE PROPER OPERATION OF THE ELECTRIC GENERATOR. LEGACY COMPONENT DESC: Generator
Action required: 705 - Other - as specified
Due 3 July 2002
Resolved 24 July 2002
Resolution: GENERATOR TESTED SAT.
Documentation › Certificates/Documents
Issued 19 June 2002
No resolution recorded
PROVIDE PROOF OF CURRENT SAFETY RADIO TELEPHONEY CERTIFICATE AND RADIO STATION LICENSE.
Action required: 705 - Other - as specified
Due 15 August 2002 — due date passed with no resolution recorded
Lifesaving › Hand Flares › Quantity
Issued 19 June 2002
Resolved
PROVIDE DISTRESS FLARES AS REQUIRED BY 46 CFR 180.68.
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 June 2002
Resolved 20 June 2002
Resolution: NEW FLARE KIT PROVIDED.
Documentation
Issued 20 March 2001
Resolved
PROVIDE CURRANT DOCUMENTATION STANP.
Condition: Unknown
Due 22 March 2001
Resolved 17 April 2001
Lifesaving
Issued 20 March 2001
Resolved
CONDUCT UNDERWAY EXAM AND DRILLS.
Condition: Unknown
Due 22 March 2001
Resolved 17 April 2001
Fire Fighting
Issued 20 March 2001
Resolved
SERVICE FIRE EXTINGUISHERS PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 22 March 2001
Resolved 17 April 2001
Navigation
Issued 20 March 2001
Resolved
REPAIR PORT RUNNING LIGHT.
Condition: Unknown
Due 22 March 2001
Resolved 17 April 2001
Fire Fighting
Issued 28 April 2000
Resolved
PROVIDE TAMPER SEAL ON BII EXT ON BRIDGE.
Condition: Unknown
Due 28 May 2000
Resolved 6 June 2000
Accommodation/Occupational Safety
Issued 28 April 2000
Resolved
PROVIDE CABLE TO GET 12" RAIL OPENING.
Condition: Unknown
Due 28 May 2000
Resolved 6 June 2000
Electrical
Issued 28 April 2000
Resolved
PROVIDE MARINE TYPE COVERED LIGHT FIXTURE IN CREWS QTRS.
Condition: Unknown
Due 28 May 2000
Resolved 6 June 2000
Construction/Loadline
Issued 28 April 2000
Resolved
PROVIDE HIGH WATER BILGE ALARMS IN ALL BELOW DECK COMPARTMENTS WITH AUDIO AND VISUAL INDICATORS.
Condition: Unknown
Due 28 May 2000
Resolved 6 June 2000
Documentation
Issued 28 April 2000
Resolved
PROVIDE FCC SAFETY CERTIFICATE.
Condition: Unknown
Due 28 May 2000
Resolved 6 June 2000
Lifesaving
Issued 28 April 2000
Resolved
CONDUCT UNDER WAY OPERATION AND DRILLS.
Condition: Unknown
Due 28 May 2000
Resolved 6 June 2000
Navigation
Issued 28 April 2000
Resolved
PROVIDE CURRENT CHART.
Condition: Unknown
Due 28 May 2000
Resolved 6 June 2000
Fire Fighting
Issued 28 April 2000
Resolved
PROVIDE MOUNTING BRACKET FOR BII EXT.
Condition: Unknown
Due 28 May 2000
Resolved 6 June 2000
Construction/Loadline
Issued 28 April 2000
Resolved
FREE WTD DOGS.
Condition: Unknown
Due 28 May 2000
Resolved 6 June 2000
Navigation
Issued 8 April 1999
Resolved
REPACK RUDDER BEARINGS.
Condition: Unknown
Due 8 April 1999
Resolved 8 April 1999
Construction/Loadline
Issued 8 April 1999
Resolved
CLOSE THRU HULL IN PORT VOID WITH PIPE CAP.
Condition: Unknown
Due 8 May 1999
Resolved 16 April 1999
Construction/Loadline
Issued 8 April 1999
Resolved
BACK BLOCK THRU HULL WOOD PLUG IN LAZARETTE.
Condition: Unknown
Due 8 April 1999
Resolved 8 April 1999
Electrical
Issued 8 April 1999
Resolved
REPLACE WIRE TO SQUIRREL CAGE BLOWER IN WING VOIDS WITH BOAT WIRE.
Condition: Unknown
Due 8 April 1999
Resolved 8 April 1999
Fire Fighting
Issued 8 April 1999
Resolved
SERVICE FIRE EXTINGUISHERS.
Condition: Unknown
Due 8 April 1999
Resolved 8 April 1999
Construction/Loadline
Issued 31 March 1999
Resolved
CLEAN PAINT FROM WATER TIGHT DOOR GASKETS AND KNIF EDGES AND REPAIR BOTTOM DOG WEDGES ON ER DOOR.
Condition: Unknown
Due 30 April 1999
Resolved 16 April 1999
Construction/Loadline
Issued 31 March 1999
Resolved
BOLT VERTICAL SUPPORT POST STBD SIDE OF TANK RM.
Condition: Unknown
Due 30 April 1999
Resolved 16 April 1999
Accommodation/Occupational Safety
Issued 31 March 1999
Resolved
REATTACH SAFETY RAIL ON BOW.
Condition: Unknown
Due 30 April 1999
Resolved 16 April 1999
Construction/Loadline
Issued 31 March 1999
Resolved
DOUBLE HOSE CLAMP STBD THRU HULL FITTING IN TANK RM FOR BILGE DISCHARGE.
Condition: Unknown
Due 30 April 1999
Resolved 16 April 1999
Accommodation/Occupational Safety
Issued 31 March 1999
Resolved
SECURE LADDER IS TANK ROOM.
Condition: Unknown
Due 30 April 1999
Resolved 16 April 1999
Engineering
Issued 23 June 1998
Resolved
PERMANENTLY REPAIR PORT ENGINE EXHAUST PIPE
Condition: Unknown
Due 28 June 1998
Resolved 15 July 1998
Navigation
Issued 23 June 1998
Resolved
TIGHTEN STARBOARD RUDDER PACKING
Condition: Unknown
Due 28 June 1998
Resolved 15 July 1998
Engineering
Issued 23 June 1998
Resolved
TIGHTEN STARBOARD ENGINE SHAFT PACKING
Condition: Unknown
Due 28 June 1998
Resolved 15 July 1998
Lifesaving
Issued 8 May 1997
Resolved
GRAB LINES ON 3 FORWARD B/As DETERIORATED FROM U/V EXPOSURE
Condition: Unknown
Due 9 May 1997
Resolved 5 June 1997
Lifesaving
Issued 8 May 1997
Resolved
B/As NOT FLOAT FREE, BUNGEE LASHED TO DECK
Condition: Unknown
Due 9 May 1997
Resolved 5 June 1997
Lifesaving
Issued 8 May 1997
Resolved
2 OF 3 FORWARD B/As DO NOT HAVE NAME OF VESSEL PERMANENTLY AFFIXED. ALL B/As DO NOT HAVE NUMBER OF P.O.B. PERMANENTLY AFFIXED.
Condition: Unknown
Due 9 May 1997
Resolved 5 June 1997
Lifesaving
Issued 8 May 1997
Resolved
GRAB LINE ON RING BUOY WASTED DUE TO U/V EXPOSURE. RETRO TAPE ON RING BUOYWASTED DUE TO U/V EXPOSURE.
Condition: Unknown
Due 9 May 1997
Resolved 5 June 1997
Lifesaving
Issued 8 May 1997
Resolved
8 PFDS (7 ADULT AND 1 CHILD) REJECTED DUE TO MATERIAL AND STRAP WASTING
Condition: Unknown
Due 9 May 1997
Resolved 5 June 1997
Documentation
Issued 8 May 1997
Resolved
FCC STATION LICENSE EXPIRED
Condition: Unknown
Due 9 May 1997
Resolved 5 June 1997
Fire Fighting
Issued 8 May 1997
Resolved
5 B-I AND 4 B-II PORTABLE FIRE EXTINGUISHERS NOT PROPERLY SERVICED OR TAGGED
Condition: Unknown
Due 9 May 1997
Resolved 5 June 1997
Unknown
Issued 8 May 1997
Resolved
FIRST AID KIT NOT IN ACCORDANCE W/46 CFR SUBCHAPTER Q SEC. 160.041.
Condition: Unknown
Due 9 May 1997
Resolved 5 June 1997
Engineering
Issued 8 May 1997
Resolved
PACKING GLANDS PORT AND STARBOARD ENGINES NEED TIGHTENING
Condition: Unknown
Due 9 May 1997
Resolved 5 June 1997
Lifesaving
Issued 8 May 1997
Resolved
PFD DONNING PLACARD NOT POSTED
Condition: Unknown
Due 9 May 1997
Resolved 5 June 1997
Fire Fighting
Issued 8 May 1997
Resolved
B-I PORTABLE EXTINGUISHER IN SALON AREA BRACKET INOPERABLE
Condition: Unknown
Due 8 May 1997
Resolved 5 June 1997
Navigation
Issued 8 May 1997
Resolved
BULB IN MAG COMPASS LIGHT BURNED OUT
Condition: Unknown
Due 9 May 1997
Resolved 5 June 1997
Documentation
Issued 8 May 1997
Resolved
CHARTS/PUBS OUTDATED, INCLUDING: TIDE TABLES, CURRENT TABLES, NOTICES TO MARINERS, COAST PILOT, RULES OF THE ROAD.
Condition: Unknown
Due 9 May 1997
Resolved 5 June 1997
Lifesaving
Issued 8 May 1997
Resolved
RETRO TAPE ON B/As DETERIORATED
Condition: Unknown
Due 5 June 1997
Resolved 5 June 1997
Electrical
Issued 2 May 1995
Resolved
AUXILLARY GENERATOR APART FOR REPAIRS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 20 May 1995
Resolved 14 September 1995
Construction/Loadline
Issued 2 May 1995
Resolved
DOGS ON FORPEAK HATCH NOT FUNCTIONAL. HATCH NOT WATERTIGHT. _x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 20 May 1995
Resolved 14 September 1995
Lifesaving
Issued 2 May 1995
Resolved
55 ADULT LIFEJACKETS WASTED DUE TO DRYROT FABRIC. ALL BUT 06 REPLACED FROM DOCK XTRAS. 06 REQ TO BE REPLACED PRIOR TO 20 MAY 95._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 20 May 1995
Resolved 14 September 1995
Construction/Loadline
Issued 2 May 1995
Resolved
FASTENERS(1/2X6INCH GALVINIZED CARRIAGE BOLTS) FRAME TO FLOOR GROSSLY WASTED._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 5 May 1995
Resolved 22 May 1995
Navigation
Issued 4 May 1993
Resolved
Provide copies of Subchapter T, Tide Tables, and Coast Pilot.
Condition: Unknown
Due 4 May 1993
Resolved 4 May 1993
Construction/Loadline
Issued 4 May 1993
Resolved
Replace or repair watertight door to Engine room.
Condition: Unknown
Due 4 May 1993
Resolved 4 May 1993
Navigation
Issued 20 May 1992
Resolved
Obtain light list for pilothouse._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 20 May 1992
Resolved 20 May 1992
Lifesaving
Issued 20 May 1992
Resolved
Unfasten buoyant apparatus from deck while carrying passengers._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 20 May 1992
Resolved 20 May 1992
Navigation
Issued 20 May 1992
Resolved
Obtain Current Tables for pilothouse._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 20 May 1992
Resolved 20 May 1992
Navigation
Issued 20 May 1992
Resolved
Obtain Notice to Mariners for pilothouse._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 20 May 1992
Resolved 20 May 1992
Navigation
Issued 20 May 1992
Resolved
Obtain '91 edition of COLREGS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 20 May 1992
Resolved 20 May 1992
Lifesaving
Issued 20 May 1992
Resolved
obtain one adult pfd to replace missing item. Until replacement numbers ofpersons carried is reduced to 105._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 20 May 1992
Resolved 20 May 1992
Lifesaving
Issued 20 May 1992
Resolved
Demonstrate light attached to ring buoy works properly._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 20 May 1992
Resolved 20 May 1992
Navigation
Issued 20 May 1992
Resolved
Obtain Tide Tables for pilothouse._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 20 May 1992
Resolved 20 May 1992
Navigation
Issued 20 May 1992
Resolved
Raise anchor light so that it is above and clear of all other obstructions._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 20 May 1992
Resolved 20 May 1992
Electrical
Issued 1 May 1991
Resolved
PROVIDE FREQUENCY METER FOR GENERATOR
Condition: Unknown
Due 1 May 1991
Resolved 1 May 1991
Electrical
Issued 1 May 1991
Resolved
REPLACE SOLIDCORE WIRE THROUGHOUT VESSEL WITH STRANDED CONDUCTOR WIRE
Condition: Unknown
Due 1 May 1991
Resolved 1 May 1991
Documentation
Issued 2 May 1990
Resolved
SUBMIT A LETTER TO THE COAST GUARD STATING THAT YOUR DRUG TESTING PROGRAM HAS BEEN STARTED
Condition: Unknown
Due 2 May 1990
Resolved 2 May 1990
Construction/Loadline
Issued 14 April 1989
Resolved
RENEW CLAMPS PORT SIDE & STBD SIDE LAZZARETTE
Condition: Unknown
Due 14 April 1989
Resolved 14 April 1989
Construction/Loadline
Issued 14 April 1989
Resolved
RENEW ROTTED PLANKING PORT SIDE OF LAZARETTE IN AREA OF SECOND FRAME FROM TRANSOM
Condition: Unknown
Due 14 April 1989
Resolved 14 April 1989
Construction/Loadline
Issued 14 April 1989
Resolved
RENEW ROTTED PLANKING PORT SIDE OF ENGINEROOM IN AREA OF SECOND, THIRD & FOURTH FRAMES
Condition: Unknown
Due 14 April 1989
Resolved 14 April 1989
Construction/Loadline
Issued 14 April 1989
Resolved
RENEW ROTTED SECTION OF STARBORAD OUTBOARD ENINE MOUNT
Condition: Unknown
Due 14 April 1989
Resolved 14 April 1989
Electrical
Issued 14 April 1989
Resolved
PROVIDE AMMETER FOR INSTALLED BATTERY CHARGER
Condition: Unknown
Due 14 April 1989
Resolved 14 April 1989
Construction/Loadline
Issued 14 April 1989
Resolved
PROVIDE AND INSTALL CAPTIVE CHAIN TO WEATHER DECK HATCHES
Condition: Unknown
Due 14 April 1989
Resolved 14 April 1989
Lifesaving
Issued 14 April 1989
Resolved
PROVIDE 10' LINE THAT ATTACHES WATER LIGHT TO RING BOUY
Condition: Unknown
Due 14 April 1989
Resolved 14 April 1989
Navigation
Issued 14 April 1989
Resolved
REPLACE ANCHOR LIGHT
Condition: Unknown
Due 14 April 1989
Resolved 14 April 1989
Navigation
Issued 14 April 1989
Resolved
REPLACE GRABLINES WITH 6' GRAB LINES ON TWO LIFEFLOATS & TWO BOUYANT APPAR ACTUAL COMPLIANCE DATE FOR REQUIREMENTS 1-5: 14MAY89
Condition: Unknown
Due 14 April 1989
Resolved 14 April 1989
Construction/Loadline
Issued 14 April 1989
Resolved
RENEW THE SECOND FRAME FWD OF TRANSOM, PORT SIDE
Condition: Unknown
Due 14 April 1989
Resolved 14 April 1989
Electrical
Issued 4 May 1988
Resolved
PROVIDE A GUARD ON GENERATOR V-BELT.
Condition: Unknown
Due 4 May 1988
Resolved 4 May 1988
Fire Fighting
Issued 4 May 1988
Resolved
PROVIDE ONE B-II HAND PORTABLE FIRE EXTINGUISHER.
Condition: Unknown
Due 4 May 1988
Resolved 4 May 1988
Electrical
Issued 4 May 1988
Resolved
PROVIDE INFORMATION THAT THE LINING INSIDE THE GENERATOR STARTING BATTERY BOX IS RESISTANT TO DETERIORATING ACTION OF THE ELECTROLYTE OR LINE IT WITHLEAD OR FIBERGLASS.
Condition: Unknown
Due 4 May 1988
Resolved 4 May 1988
Unknown
Issued 4 May 1988
Resolved
PROVIDE AND INSTALL CAPTIVE CHAINS OF WEATHER DECK HATCHES.
Condition: Unknown
Due 4 May 1988
Resolved 4 May 1988
Engineering
Issued 4 May 1988
Resolved
MAKE PERMANENT REPAIRS TO BILGE DISCHARGE THRU HULL IN TRANSOM AT NEXT DRYDOCK.
Condition: Unknown
Due 4 May 1988
Resolved 4 May 1988
Engineering
Issued 4 May 1988
Resolved
INSTALL 30X30 FLAME SCREENS IN FUEL TANK VENT LINES AT THE ENDS.
Condition: Unknown
Due 4 May 1988
Resolved 4 May 1988
Electrical
Issued 4 May 1988
Resolved
PROVIDE AMMETER FOR INSTALLED BATTERY CHARGER.
Condition: Unknown
Due 4 May 1988
Resolved 4 May 1988
Construction/Loadline
Issued 4 May 1988
Resolved
REPAIR LEAK AT THE BOTTOM OF THE COLLISION BULKHEAD.
Condition: Unknown
Due 4 May 1988
Resolved 4 May 1988
Engineering
Issued 4 May 1988
Resolved
PROVIDE RIGID OIL RESISTANT BILGE DISCHARGE HOSE ON ELECTRIC BILGE PUMPS AT NEXT DRYDOCK.
Condition: Unknown
Due 4 May 1988
Resolved 4 May 1988
Lifesaving
Issued 4 May 1988
Resolved
PROVIDE TWO 4FT PADDLES FOR EACH LIFEFLOAT.
Condition: Unknown
Due 4 May 1988
Resolved 4 May 1988
Engineering
Issued 4 May 1988
Resolved
PROVIDE INDICATOR LIGHTS FOR AUTOMATIC BILGE PUMPS AT THE STEERING STATION.
Condition: Unknown
Due 4 May 1988
Resolved 4 May 1988