Records from 2016 to 2026. Most recent: inspection, 3 February 2026.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 3 February 2026
Resolved
Gauges to indicate engine revolutions per minute (RPM), jacket water discharge temperature, and lubricating oil pressure must be provided for all propulsion engines installed in the vessel. The gauges must be readily visible at the operating station.
Observed Port engine alarm panel at the operating station inoperable.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 3 February 2026
Resolved 3 February 2026
Resolution: Received video of functioning alarm panel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 February 2025
Resolved
A vessel must be provided with a satisfactory arrangement for draining any watertight compartment, other than small buoyancy compartments, under all practicable conditions. Sluice valves are not permitted in watertight bulkheads. MI identified a cracked housing on the steering compartment bilge piping check valve. Effect repairs to the satisfaction of the attending marine inspector. 46CFR182.500(a). 60c.
Action required: 60 - Rectify deficiencies prior to movement
Due 6 February 2025
Resolved 11 February 2025
Resolution: new check valve installed.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 6 February 2025
Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. MI identified cracks and missing gasket material on the sealing edge of the engine room hatches rendering them not vapor tight. Effect repairs to the satisfaction of attending marine inspector. 46CFR176.830 (a). 60c.
Action required: 60 - Rectify deficiencies prior to movement
Due 6 February 2025
Resolved 11 February 2025
Resolution: Gaskets repaired and fire caulk used to seal gaps in the knife edge corners
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 6 February 2025
Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules, except that a vessel of more than 19.8 meters (65 feet) in length must also have navigation lights that meet UL 1104, “Standards for Marine Navigation Lights,” or other standard specified by the Commandant. MI observed the Stbd nav light inoperable. 46CFR183.420. 60c.
Action required: 60 - Rectify deficiencies prior to movement
Due 6 February 2025
Resolved 11 February 2025
Resolution: new stbd nav light installed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 6 February 2025
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. MI identified oil soaked windings in the generator. Clean and effect repairs to the source of the oil leak to the satifaction of the attending marine inspector. 46CFR182.100. 60c.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 6 February 2025
Resolved 11 February 2025
Resolution: windings of the generator cleaned to satisfaction of attending MI
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 February 2025
Resolved
Electrical equipment on a vessel must be installed and maintained to: Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Mi identified multiple dead end wires exposed in the fwd compartment. Effect repairs or remove wires to the satisfaction of the attending marine inspector. 46CFR183.200 (b). 16c.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 February 2025
Resolved 11 February 2025
Resolution: Dead end wires properly terminated
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 5 February 2024
Resolved
All cable and wire must be installed with metal supports spaced not more than 610 millimeters (24 inches) apart, and in such a manner as to avoid chafing and other damage. The use of plastic tie wraps must be limited to bundling or retention of multiple cable installations, and not used as a means of support. Marine Inspector identified an electrical distribution cable in the steering space supported by plastic wire ties. Install metallic supports to the satisfaction of the attending Marine Inspector.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 March 2024
Resolved 1 March 2024
Resolution: Corrected deficiency. Provided cable run brackets 24" apart to the satisfaction of the MI.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 5 February 2024
Resolved
A vessel must be provided with a main steering gear that is of adequate strength and capable of steering the vessel at all service speeds. Marine Inspector identified hydraulic fluid seeping from the inboard seal of the steering ram and missing hardware on steering ram mounting base. Install hardware and correct leak to the satisfaction of the attending Marine Inspector.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 March 2024
Resolved 1 March 2024
Resolution: Vessel operator replaced damaged actuator seal and missing hardware, and submitted photographic and video evidence of repairs to the satisfaction of the attending MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 27 June 2022
Resolved
When the exhaust cooling water system is separate from the engine cooling water system, a suitable warning device, visual or audible, must be installed at the operating station to indicate any reduction in normal water flow in the exhaust cooling system. MI observed no warning device for the exhaust cooling water system.
Cite: 46 CFR 182.425(b)(5)
60c
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Due 7 February 2023
Resolved 16 February 2023
Resolution: Vessel installed new temperature sensor on exhaust gas cooling system meeting the requirements of 46 CFR 182.425(b)(5). Conducted def check and found operation of sensor sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 1 July 2021
Resolved
The exhaust piping must be so arranged as to prevent the backflow of water from reaching the exhaust port under normal conditions. Port exhaust flap valve on transom was missing. Replace to the satisfaction of the attending marine inspector.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Resolved 6 July 2021
Resolution: Rep provided picture of newly installed exhaust flapp valve.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 1 July 2021
Resolved
Piping, including valves, pipe fittings and flanges conveying vapor, gas or liquid, the temp of which exceeds 150 degrees F must be suitablity insulated where necessary to prevent injuries. Generator exhaust lagging missing. Replace to the satisfaction of the attending marine inspector prior to operating generator.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 6 July 2021
Resolution: Rep provided pictures of new lagging/insulation on generator exhaust pipe.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 1 July 2021
Resolved
A generator or motor designed for 40 °C (104 °F) may be used in 50 °C (122 °F) ambient locations provided the generator or motor is derated to 80 percent of the full load rating, and the rating or setting of the overcurrent devices is reduced accordingly. Provide proof from manufacturer that generator is rated for 50 degrees given the insulation rating on the generator was class H, de-rate the generator to 80 % of the full rated load or replace generator with one rated for 50 degree ambient temperatures prior to operating generator.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 15 December 2021
Resolution: Vessel rep provided a picture of a new generator lable plate from the manufacturer indicating 50 degree ambient temperature rating.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 July 2021
Resolved
Propulsion machinery must be capable of operating at constant marine load. Upon testing of fireboy, engines secured as intended, port engine would not restart due to weak battery. Provide proof of proper operation to the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 6 July 2021
Resolution: Vessel representative replaced both batteries for port engine.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 1 July 2021
Resolved
A vessel not required to have a power driven fire pump must have at least three 9.5 liter (2 1/2 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. The words “FIRE BUCKET” must be stenciled in a contrasting color on each bucket. Vessel's fire buckets were improperly labled and did not have lanyards. Rectify to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 6 July 2021
Resolution: Rep provided pictures of properly labeled fire buckets with attached lanyards.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 1 July 2021
Resolved
Crew training shall be logged or otherwise documented for review by the Coast Guard upon request. Master could not produce current ship's log documenting crew training. Provide proof of ship's log with crew training entries to the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2021
Resolved 6 July 2021
Resolution: Rep provided pictures of ships logs indicating drills conducted.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 5 August 2020
Resolved
Generator exhaust leaks exhaust fumes. Exhaust gas must not leak from piping or any connections. Repair to the satisfaction of the attending USCG Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 August 2020
Resolution: Vessel made corrective repairs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 August 2020
Resolved
Port main diesel engine leaks lube oil. All observed unsafe practices, fire hazards, and other hazardous situations must be corrected. Repair to the satisfaction of the attending marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 August 2020
Resolution: Corrected on the spot.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 July 2020
Resolved
STBD main diesel engine leaks lube oil. All observed unsafe practices, fire hazards, and other hazardous situations must be corrected. Repair to the satisfaction of the attending marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 August 2020
Resolution: Corrected on the spot.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 13 July 2017
Resolved
Flow sensor for wet exhaust is missing on Starboard main. Install temp sensor on STBD Exhaust. 46 CFR 182.425 (b)(5)
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 21 July 2017
Resolved 17 July 2017
Resolution: Installed new temp gauge on STBD main exhaust
Engineering › Sea-water System (primary cooling) › Piping
Issued 13 July 2017
Resolved
Replace hose from sea strainer to inlet connection on the port engine for separate raw water pump for wet exhaust due to chafing/cut in the outer sheeting.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 21 July 2017
Resolved 17 July 2017
Resolution: Hose was replaced
Navigation › Collision/Grounding Avoidance › Navigation Bridge Visibility
Issued 13 July 2017
Resolved
Install bracket for ships bell. Nav rule 33
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 21 July 2017
Resolved 17 July 2017
Resolution: Bracket for bell was re-installed