MAURY USCG vessel records Sign in
← All vessels

DASH

DASH is a 1997 passenger vessel (inspected). The Coast Guard has recorded 28 inspections since 1998, most recently in February 2026, along with 24 deficiencies.

Records from 1998 to 2026. Most recent: inspection, 3 February 2026.

Built
1997
Last inspected
3 February 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDJ4488
465838
Flag
UNITED STATES
367778160
Maury page id
psix-465838

Inspections, by type

Years with a record 24 calendar years (1998–2026)
The 28 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)42.0 ft × 15.0 ft × 5.0 ft
Registered tonnagegross 21 / net 16
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMIDSHIP MARINE INC · HARVEY, LA, UNITED STATES · built 1997
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 16 July 2026 · expires 31 August 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it21 - Simplified, Gross Ton
16 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDJ4488MMSI 367778160 · active · compulsorily equipped · granted 21 March 2017, expires 21 March 2027
WDF8490MMSI 367495420 · expired · compulsorily equipped · granted 17 June 2011, cancelled 21 August 2021 · licensed under a name not among this hull’s recorded names (not shown)
WDA4478MMSI 366809870 · cancelled · voluntarily equipped · granted 5 April 2011, cancelled 9 August 2011 · licensed under a name not among this hull’s recorded names (not shown)
WCX9957MMSI not assigned · expired · compulsorily equipped · granted 3 March 1998, cancelled 3 May 2008
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 28

3 February 2026 Annual Inspection · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8292030
16 January 2025 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8064602
5 February 2024 Administrative Inspection · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7860544
27 June 2022 Deficiency Check · Construction Oversight · Drydock Exam · COI Inspection · Internal Structural Exam · Simplified Stability Test
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7511868
2 June 2021 Annual Inspection · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7213239
27 July 2020 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7017678
23 May 2019 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6684868
1 June 2018 COI Inspection · Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6431210
13 July 2017 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6205741
12 April 2016 COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5852825
2 December 2011 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4199992
30 March 2010 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3704910
13 April 2009 Re-Inspection · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3451487
5 June 2008 Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3228049
18 April 2008 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3187183
8 February 2008 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3144332
14 June 2007 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2961813
30 April 2007 Annual Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2919208
24 April 2006 COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2632019
20 January 2006 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2569870
13 April 2005 Hull Examination · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2332844
16 June 2004 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2100033
17 April 2003 Hull Examination · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1816089
24 April 2002 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1609894
26 April 2001 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1452802
11 February 2000 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1046038
28 January 1999 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1410018
2 February 1998 Initial Certification · Initial Construction-Excluding Oversight · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1431909

Deficiency record · 24

08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 3 February 2026 Resolved
Gauges to indicate engine revolutions per minute (RPM), jacket water discharge temperature, and lubricating oil pressure must be provided for all propulsion engines installed in the vessel. The gauges must be readily visible at the operating station. Observed Port engine alarm panel at the operating station inoperable.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 3 February 2026
Resolved 3 February 2026
Resolution: Received video of functioning alarm panel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 February 2025 Resolved
A vessel must be provided with a satisfactory arrangement for draining any watertight compartment, other than small buoyancy compartments, under all practicable conditions. Sluice valves are not permitted in watertight bulkheads. MI identified a cracked housing on the steering compartment bilge piping check valve. Effect repairs to the satisfaction of the attending marine inspector. 46CFR182.500(a). 60c.
Action required: 60 - Rectify deficiencies prior to movement
Due 6 February 2025
Resolved 11 February 2025
Resolution: new check valve installed.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 6 February 2025 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. MI identified cracks and missing gasket material on the sealing edge of the engine room hatches rendering them not vapor tight. Effect repairs to the satisfaction of attending marine inspector. 46CFR176.830 (a). 60c.
Action required: 60 - Rectify deficiencies prior to movement
Due 6 February 2025
Resolved 11 February 2025
Resolution: Gaskets repaired and fire caulk used to seal gaps in the knife edge corners
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 6 February 2025 Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules, except that a vessel of more than 19.8 meters (65 feet) in length must also have navigation lights that meet UL 1104, “Standards for Marine Navigation Lights,” or other standard specified by the Commandant. MI observed the Stbd nav light inoperable. 46CFR183.420. 60c.
Action required: 60 - Rectify deficiencies prior to movement
Due 6 February 2025
Resolved 11 February 2025
Resolution: new stbd nav light installed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 6 February 2025 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. MI identified oil soaked windings in the generator. Clean and effect repairs to the source of the oil leak to the satifaction of the attending marine inspector. 46CFR182.100. 60c.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 6 February 2025
Resolved 11 February 2025
Resolution: windings of the generator cleaned to satisfaction of attending MI
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 February 2025 Resolved
Electrical equipment on a vessel must be installed and maintained to: Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Mi identified multiple dead end wires exposed in the fwd compartment. Effect repairs or remove wires to the satisfaction of the attending marine inspector. 46CFR183.200 (b). 16c.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 February 2025
Resolved 11 February 2025
Resolution: Dead end wires properly terminated
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 5 February 2024 Resolved
All cable and wire must be installed with metal supports spaced not more than 610 millimeters (24 inches) apart, and in such a manner as to avoid chafing and other damage. The use of plastic tie wraps must be limited to bundling or retention of multiple cable installations, and not used as a means of support. Marine Inspector identified an electrical distribution cable in the steering space supported by plastic wire ties. Install metallic supports to the satisfaction of the attending Marine Inspector.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 March 2024
Resolved 1 March 2024
Resolution: Corrected deficiency. Provided cable run brackets 24" apart to the satisfaction of the MI.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 5 February 2024 Resolved
A vessel must be provided with a main steering gear that is of adequate strength and capable of steering the vessel at all service speeds. Marine Inspector identified hydraulic fluid seeping from the inboard seal of the steering ram and missing hardware on steering ram mounting base. Install hardware and correct leak to the satisfaction of the attending Marine Inspector.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 March 2024
Resolved 1 March 2024
Resolution: Vessel operator replaced damaged actuator seal and missing hardware, and submitted photographic and video evidence of repairs to the satisfaction of the attending MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 27 June 2022 Resolved
When the exhaust cooling water system is separate from the engine cooling water system, a suitable warning device, visual or audible, must be installed at the operating station to indicate any reduction in normal water flow in the exhaust cooling system. MI observed no warning device for the exhaust cooling water system. Cite: 46 CFR 182.425(b)(5) 60c
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Due 7 February 2023
Resolved 16 February 2023
Resolution: Vessel installed new temperature sensor on exhaust gas cooling system meeting the requirements of 46 CFR 182.425(b)(5). Conducted def check and found operation of sensor sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 1 July 2021 Resolved
The exhaust piping must be so arranged as to prevent the backflow of water from reaching the exhaust port under normal conditions. Port exhaust flap valve on transom was missing. Replace to the satisfaction of the attending marine inspector.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Resolved 6 July 2021
Resolution: Rep provided picture of newly installed exhaust flapp valve.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 1 July 2021 Resolved
Piping, including valves, pipe fittings and flanges conveying vapor, gas or liquid, the temp of which exceeds 150 degrees F must be suitablity insulated where necessary to prevent injuries. Generator exhaust lagging missing. Replace to the satisfaction of the attending marine inspector prior to operating generator.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 6 July 2021
Resolution: Rep provided pictures of new lagging/insulation on generator exhaust pipe.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 1 July 2021 Resolved
A generator or motor designed for 40 °C (104 °F) may be used in 50 °C (122 °F) ambient locations provided the generator or motor is derated to 80 percent of the full load rating, and the rating or setting of the overcurrent devices is reduced accordingly. Provide proof from manufacturer that generator is rated for 50 degrees given the insulation rating on the generator was class H, de-rate the generator to 80 % of the full rated load or replace generator with one rated for 50 degree ambient temperatures prior to operating generator.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 15 December 2021
Resolution: Vessel rep provided a picture of a new generator lable plate from the manufacturer indicating 50 degree ambient temperature rating.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 July 2021 Resolved
Propulsion machinery must be capable of operating at constant marine load. Upon testing of fireboy, engines secured as intended, port engine would not restart due to weak battery. Provide proof of proper operation to the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 6 July 2021
Resolution: Vessel representative replaced both batteries for port engine.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 1 July 2021 Resolved
A vessel not required to have a power driven fire pump must have at least three 9.5 liter (2 1/2 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. The words “FIRE BUCKET” must be stenciled in a contrasting color on each bucket. Vessel's fire buckets were improperly labled and did not have lanyards. Rectify to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 6 July 2021
Resolution: Rep provided pictures of properly labeled fire buckets with attached lanyards.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 1 July 2021 Resolved
Crew training shall be logged or otherwise documented for review by the Coast Guard upon request. Master could not produce current ship's log documenting crew training. Provide proof of ship's log with crew training entries to the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2021
Resolved 6 July 2021
Resolution: Rep provided pictures of ships logs indicating drills conducted.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 5 August 2020 Resolved
Generator exhaust leaks exhaust fumes. Exhaust gas must not leak from piping or any connections. Repair to the satisfaction of the attending USCG Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 August 2020
Resolution: Vessel made corrective repairs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 August 2020 Resolved
Port main diesel engine leaks lube oil. All observed unsafe practices, fire hazards, and other hazardous situations must be corrected. Repair to the satisfaction of the attending marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 August 2020
Resolution: Corrected on the spot.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 July 2020 Resolved
STBD main diesel engine leaks lube oil. All observed unsafe practices, fire hazards, and other hazardous situations must be corrected. Repair to the satisfaction of the attending marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 August 2020
Resolution: Corrected on the spot.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 13 July 2017 Resolved
Flow sensor for wet exhaust is missing on Starboard main. Install temp sensor on STBD Exhaust. 46 CFR 182.425 (b)(5)
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 21 July 2017
Resolved 17 July 2017
Resolution: Installed new temp gauge on STBD main exhaust
Engineering › Sea-water System (primary cooling) › Piping
Issued 13 July 2017 Resolved
Replace hose from sea strainer to inlet connection on the port engine for separate raw water pump for wet exhaust due to chafing/cut in the outer sheeting.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 21 July 2017
Resolved 17 July 2017
Resolution: Hose was replaced
Navigation › Collision/Grounding Avoidance › Navigation Bridge Visibility
Issued 13 July 2017 Resolved
Install bracket for ships bell. Nav rule 33
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 21 July 2017
Resolved 17 July 2017
Resolution: Bracket for bell was re-installed
Lifesaving › Lifefloat › Float-free Link
Issued 24 April 2006 Resolved
Install approved float free link.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 April 2006
Resolved 28 April 2006
Resolution: Approved float free link installed.
Lifesaving › Lifefloat › Painter
Issued 24 April 2006 Resolved
Provide painter.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 April 2006
Resolved 28 April 2006
Resolution: Painter provided.
Lifesaving
Issued 2 February 1998 Resolved
CONDUCT AND LOG DRILLS IAW 46CFR185.
Condition: Unknown
Due 2 March 1998
Resolved 18 March 1998

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.