MAURY USCG vessel records Sign in
← All vessels

NAVEGANTE

NAVEGANTE is a 1970 passenger vessel (inspected). The Coast Guard has recorded 99 inspections since 1985, most recently in January 2026, along with 198 deficiencies — 1 with no resolution recorded —, 3 operational controls and 4 casualty investigations between 2003 and 2007.

Records from 1985 to 2026. Most recent: inspection, 27 January 2026.

Built
1970
Last inspected
27 January 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDH3694
Flag
UNITED STATES
368160740
Maury page id
psix-46585

Inspections, by type

…with no type recorded19
Years with a record 38 calendar years (1985–2026)
The 99 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)58.2 ft × 19.1 ft × 7.6 ft
Registered tonnagegross 73 / net 50
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderRUSSELL A IZOR · VENICE, CA, UNITED STATES · built 1970
Hull materialWood
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portREDONDO BEACH, CA
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 29 May 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it73 - Regulatory (Subpart C or D), Gross Ton
50 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDL7484MMSI 368160740 · active · compulsorily equipped · granted 2 September 2020, expires 2 September 2030
WDH3694MMSI 367609920 · expired · compulsorily equipped · granted 13 March 2014, cancelled 18 May 2024
WCX5640MMSI 366735360 · expired · voluntarily equipped · granted 21 June 2007, cancelled 26 August 2017
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 99

27 January 2026 Annual Inspection · Vessel Attendance
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8271900
18 June 2025 In-Service Inspection · Special Consideration
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8150217
2 June 2025 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8093867
19 March 2025 Internal Structural Exam · Hull Examination · Examination of Repairs · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8080972
20 October 2024 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8016968
5 April 2024 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7890697
20 March 2024 COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7831983
12 September 2023 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7762718
19 April 2023 Hull Examination · Examination of Repairs · Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7620632
19 April 2023 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7665925
31 August 2022 Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7547575
29 August 2022 COI Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7504189
14 October 2021 Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7332087
7 April 2021 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7170073
1 September 2020 Administrative Inspection · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7047440
17 March 2020 Simplified Stability Test
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6931556
8 October 2019 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6830957
12 June 2019 Deficiency Check · COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6649801
15 May 2019 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6612049
5 June 2018 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6380858
27 June 2017 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6188254
12 June 2017 Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6169828
7 June 2016 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5848566
27 May 2014 COI Inspection · DAPI Audit
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4846460
16 December 2010 Type not recorded
No type recorded · Maritime Safety & Security Team San Francisco (91105) · Activity 3912201
22 October 2010 Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3875320
10 March 2010 DAPI Audit · COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3677053
11 March 2009 DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3416006
10 November 2008 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3360589
22 September 2008 Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3330504
19 March 2008 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3164116
14 March 2007 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2868651
12 October 2006 Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2799250
16 March 2006 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2595369
8 June 2005 Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2382701
6 June 2005 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2385354
6 June 2005 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2389023
21 March 2005 Deficiency Check · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2301502
19 November 2004 Examination of Repairs · Deficiency Check · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2201033
8 March 2004 Annual Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2004750
4 June 2003 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1810376
20 February 2003 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1746125
29 November 2002 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1701362
19 March 2002 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1493696
21 February 2002 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1488108
19 July 2001 Damage Survey
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1379531
17 July 2001 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 32718
1 March 2001 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1382180
6 February 2001 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1379305
25 July 2000 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1053516
30 March 2000 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 817114
9 March 2000 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1450427
8 February 2000 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 815807
22 April 1999 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 793696
11 March 1999 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1393140
9 March 1999 Plan Review "T" Boat
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 804196
12 November 1998 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1400873
6 August 1998 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 722652
5 August 1998 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 800282
8 July 1998 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1453492
24 June 1998 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 36060
24 February 1998 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1427467
18 December 1997 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 722653
1 October 1997 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 110615
21 April 1997 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1105383
11 March 1997 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1465292
11 December 1996 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1435842
8 November 1996 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1374787
19 June 1996 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1078412
11 April 1996 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1385685
7 April 1995 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1157230
16 November 1994 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 865415
5 May 1994 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 858151
5 April 1994 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 855831
29 December 1993 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 851326
29 November 1993 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1158356
16 November 1993 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 643266
5 November 1993 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1156715
27 April 1993 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 831944
15 November 1992 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 212148
5 August 1992 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 216704
27 May 1992 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1270856
22 April 1992 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1259588
16 April 1991 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1224029
17 October 1990 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1235839
10 April 1990 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1222494
9 May 1989 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1350074
26 April 1989 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1346957
27 June 1988 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1205881
9 May 1988 Deficiency Check · Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1043456
19 April 1988 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1038104
20 July 1987 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1329137
19 June 1987 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1012646
28 May 1987 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1011821
21 May 1987 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1333823
28 May 1986 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1305478
25 March 1986 Credit Drydock
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1306940
26 June 1985 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1288270
7 May 1985 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1287912

Deficiency record · 198

01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 27 January 2026 No resolution recorded
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 20 October 2024 Resolved
Each survival craft must be secured to the vessel by a painter with a float-free link permanently attached to the vessel except that a float-free link is not required if the vessel operates only on waters not as deep as the length of the painter and stowed so that when the vessel sinks the survival craft floats free and, if inflatable, inflates automatically. IBA was found secured to vessel and painter line not attached to weak link; All required survival craft listed on COI must be in compliance with regulations at all times when passengers are carried regardless of route or type of service the vessel is employed in.
Action required: 10 - Deficiency Rectified
Due 20 October 2024
Resolved 20 October 2024
Resolution: Securing device was removed and painter line properly attached to weak link.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 20 October 2024 Resolved
The master of the vessel shall ensure that each EPIRB, other than an EPIRB in an inflatable liferaft, must be tested monthly, using the integrated test circuit and output indicator, to determine that it is operative. The EPIRB test shall be logged or otherwise documented, as applicable. Vessel master was unable to produce documentation showing EPRIB monthly test after April 2024. MI observed EPRIB test and master logged test in vessel log book.
Action required: 10 - Deficiency Rectified
Due 20 October 2024
Resolved 20 October 2024
Resolution: MI observed EPRIB test and master logged test in vessel log book.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 March 2024 Resolved
Each life jacket, immersion suit, and ring life buoy must be marked in clearly legible block capital letters with the vessel's name. MI observed Life Ring & Life Jackets without vessel's name and not in block capital letters.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 April 2024
Resolved 3 April 2024
Resolution: Observed Lifejackets labeled correctly.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 20 March 2024 Resolved
Abandon ship and man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include the following information: 1)Date of the drill and trainings 2) General description of the drill scenario and training topics. MI observed no entries as described.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 April 2024
Resolved 3 April 2024
Resolution: Observed correct logged entries.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 20 March 2024 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date:1) US Coast Pilot 2) Coast guard Light List 3) Tide Tables and 4) Current tables MI observed expired pubs.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 April 2024
Resolved 3 April 2024
Resolution: Def resolved
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 31 August 2022 Resolved
A device must be provided to automatically secure power ventilation serving the protected space and engines that draw intake air from the protected space. Vessel's installed CO2 system does not secure ventilation or shut down of engines.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 31 August 2022
Resolved 1 September 2022
Resolution: MI verified that the engines and power ventilation shut down upon activation of the CO2 system.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 31 August 2022 Resolved
Each portable fire extinguisher must be inspected and maintained in accordance with NFPA 10. Vessel's portable fire extinguisher in the passenger berthing had no charge.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 31 August 2022
Resolved 1 September 2022
Resolution: Vessel has replaced the extinguisher with one with adequate charge that has been serviced.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 31 August 2022 Resolved
Each connection to a conductor must be made within an enclosure. MI discovered numerous conductor splices not within an enclosure.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 September 2022
Resolved 1 September 2022
Resolution: All conductor splices are now in conduit.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 31 August 2022 Resolved
Each collision bulkhead must not be fitted with any type of penetration or opening. Vessel shall submit plans to restore collision bulkhead in accordance with 46 CFR 179.310.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 September 2022
Resolved 30 September 2022
Resolution: Operator has submitted plans to local unit for plan review. Opted to route to MSC for approval due to complexity of issue.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 29 August 2022 Resolved
A vessel must be operated in accordance with applicable laws and regulations in such a manner as to afford adequate precaution against hazards that might endanger the vessel and the persons to be transported. Deficiencies 02-04 provide objective evidence that the vessel is substandard and not proactively managing technical and operational requirements. Vessel must complete a satisfactory expanded annual inspection prior to any movement.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 29 August 2022
Resolved 1 September 2022
Resolution: All major deficiencies have been resolved. MI has briefed CPREV and he has authorized that the vessel's flag state detention can be lifted.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 29 August 2022 Resolved
An adult life jacket must be provided for each person carried on board a vessel. Vessel had 22 unapproved life jackets. 02 on board life jackets were not in a serviceable condition, 41 were missing lights, and 10 had non-operational lights. 46 CFR 180.71(a)
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 29 August 2022
Resolved 31 August 2022
Resolution: MI verified that vessel carries 74 approved type 1 pfd's (8 child) and that 50 have lights.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 29 August 2022 Resolved
Each survival craft must be stowed so that when the vessel sinks the survival craft floats free and, if inflatable, inflates automatically. Vessel's life raft was strapped down preventing float free arrangement. 46 CFR 180.130(a)(2)
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 29 August 2022
Resolved 31 August 2022
Resolution: MI verified proper installation and serivicing of the installed 50 man life raft.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 29 August 2022 Resolved
Fire extinguishing equipment installed on a vessel in excess of the requirements of 46 CFR 181.400 and 181.500 must be designed, constructed, installed, and maintained in accordance with a recognized industry standard acceptable to the Commandant (CG-ENG-4). Independent modular smoke detector located in passenger and crew berthing was found to be inoperable.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 29 August 2022
Resolved 31 August 2022
Resolution: MI verified installation and operation of all smoke detectors required.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 29 August 2022 Resolved
A vessel on an oceans, coastwise, limited coastwise, or Great Lakes route must carry six hand orange smoke distress signals approved in accordance with § 160.037 in subchapter Q of this chapter, or other standard specified by the Commandant. Vessel operates on an oceans route and had 03 expired orange smoke distress signals. 46 CFR 180.68(a)(1)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 29 August 2022
Resolved 31 August 2022
Resolution: MI verified that the vessels flares are not expired.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 29 August 2022 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. 02 electrical panels in ER missing blanks. 46 CFR 183.200(b)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 29 August 2022
Resolved 31 August 2022
Resolution: MI verified that the vessel has installed blanks in electrical panels.
02 - Structural Conditions › N/A - No Subsystem › Wheelhouse -door -window
Issued 29 August 2022 Resolved
After loading and prior to departure and at all other times necessary to assure the safety of the vessel, the master shall determine that the vessel complies with all applicable stability requirements in the vessel's trim and stability book, stability letter, Certificate of Inspection, and Load Line Certificate, as the case may be. The vessel may not depart until it is in compliance with these requirements. Vessel's fore peak void hatch cover was missing gasket and captive chain. 46 CFR 185.315(a)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 29 August 2022
Resolved 31 August 2022
Resolution: MI verified that the hatch has a satisfactory gasket and a captive chain.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 29 August 2022 Resolved
After loading and prior to departure and at all other times necessary to assure the safety of the vessel, the master shall determine that the vessel complies with all applicable stability requirements in the vessel's trim and stability book, stability letter, Certificate of Inspection, and Load Line Certificate, as the case may be. The vessel may not depart until it is in compliance with these requirements. Vessel was utilizing fore peak void as fish hold when underway. 46 CFR 185.315(a)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 29 August 2022
Resolved 31 August 2022
Resolution: MI verified that the vessel is aware of collision bulkhead requirements and the operator is required to submit plans to rectify the collision bulkhead.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 29 August 2022 Resolved
Provision shall be made by means of plugs, covers, etc., to prevent the admission of air into the space protected. Vent closures to the E/R were inoperable. 46 CFR 181.20-35
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 29 August 2022
Resolved 31 August 2022
Resolution: MI verified proper installation and operation of ventilation closures.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 29 August 2022 Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules, except that a vessel of more than 19.8 meters (65 feet) in length must also have navigation lights that meet UL 1104, “Standards for Marine Navigation Lights,” or other standard specified by the Commandant. STBD navigation light was non-operational.
Action required: 17 - Rectify deficiencies prior to departure
Due 29 August 2022
Resolved 31 August 2022
Resolution: MI verified that the navigation light functions properly
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 29 August 2022 Resolved
A marine employer whose vessel is involved in a casualty or incident that is, or is likely to become, a serious marine incident as defined in § 4.03-2 of sub chapter A of this chapter shall comply with the requirements of § 4.06 in sub chapter A of this chapter. Vessel's required alcohol testing swabs were expired.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 September 2022
Resolved 31 August 2022
Resolution: Vessel has replaced all expired alcohol swabs.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 29 August 2022 Resolved
All escape hatches and other emergency exits shall be marked on both sides using at least 1-inch letters: "Emergency Exit, Keep Clear" , unless such markings are deemed unnecessary by the Officer in Charge, Marine Inspection. Vessel escape hatch marking was faded. 46 CFR 185.30-15(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 September 2022
Resolved 1 September 2022
Resolution: Vessel's escape hatch marking is now satisfactory.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 29 August 2022 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be satisfactory condition. Starboard main engine is missing machinery guards.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 September 2022
Resolved 1 September 2022
Resolution: Vessel installed machinery guard around the exposed serpentine belt.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 29 August 2022 Resolved
The master shall conduct drills and give instructions as necessary to ensure that all crew members are familiar wit their duties. Vessel's crew was unfamiliar with procedures for activation of CO2 system and engine resets.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 29 August 2022
Resolved 29 August 2022
Resolution: MI Conducted training with master and crew regarding operation of the CO2 system.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 14 October 2021 Resolved
Annual Inspection - Your vessel must undergo an annual inspection within 3 months before or after each anniversary date. Vessel is overdue for its annual inspection. Vessel must complete an annual inspection prior to carriage of passengers.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 14 October 2021
Resolved 15 October 2021
Resolution: DEF CLEARED
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 14 October 2021 Resolved
Renew Gasket on fwd hatch cover.
Action required: 10 - Deficiency Rectified
Due 15 October 2021
Resolved 15 October 2021
Resolution: Def Cleared
09 - Working and Living Conditions › 091 - Living Conditions › Sleeping room
Issued 14 October 2021 Resolved
Prove escape hatch cover is removable for pax below in accomodation space.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 15 October 2021
Resolved 15 October 2021
Resolution: Def Cleared.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 14 October 2021 Resolved
Prove bilge alarm and pump capabilities for all spaces as identified.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 15 October 2021
Resolved 15 October 2021
Resolution: Def Cleared.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 October 2021 Resolved
Provide electrical panel cover enclosure with metal hinges.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 October 2021
Resolved 3 November 2021
Resolution: Def Cleared
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 14 October 2021 Resolved
Provide four machinery guards on main engines.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 November 2021
Resolved 3 November 2021
Resolution: def cleared
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 14 October 2021 Resolved
Replace reflective tape on lifering.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 October 2021
Resolved 3 November 2021
Resolution: Def cleared
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 14 October 2021 Resolved
Provide two deck plates of sufficient strength and not moveable near shaft.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 November 2021
Resolved 3 November 2021
Resolution: def cleared
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 14 October 2021 Resolved
Secure with metal fastener fuel return linhe as indentified.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 15 October 2021
Resolved 15 October 2021
Resolution: Def Cleared.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 22 October 2019 Resolved
Emergency lighting automatically activated upon failure of the main light system shall be fitted along the line of escape. Provide emergency lighting in both berthing areas. prior to operating overnight or allowing passengers access to the berthing areas.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 October 2019
Resolved 29 January 2020
Resolution: Received notification from O/O that all e-lights are functional.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 12 June 2019 Resolved
Vessel has 4"x1" hole on port and starboard of transom to ventilate aft compartments. Hull openings need to be kept closed to prevent water from entering. Make transom watertight.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 July 2019
Resolved 2 August 2019
Resolution: Holes are filled in with wood and sheets of fiber glass. Permanent repair appears satisfactory.
05 - Radio Communications › N/A - No Subsystem › Operation/maintenance
Issued 12 June 2019 Resolved
FCC safety Cert is expired as of 12APR19. Provide current Safety Cert.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 June 2019
Resolved 5 July 2019
Resolution: Provided renewed and current FCC Safety Cert
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 12 June 2019 Resolved
Coast Pilot and Lights are 2011 edition. Provide current nautical publications
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 June 2019
Resolved 5 July 2019
Resolution: Provided 2019 editions.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 12 June 2019 Resolved
Found 3 adult kapok life jackets no longer serviceable. Provide 3 adult lifejackets.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 June 2019
Resolved 5 July 2019
Resolution: Provided serviceable life jacket with correct markings
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 12 June 2019 Resolved
Found 02 float lights for the a ring buoy and a life-float to be unserviceable due to crack and corrosion in way of the attaching ring. Provide 2 float lights.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 June 2019
Resolved 2 August 2019
Resolution: Vessel provided serviceable float lights for its raft and ring.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 June 2019 Resolved
Toilets are not secured from discharging directly over the side within 3NMs. Provide a lock on the overboard valve to prevent any discharge of sewage within 3NM.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 June 2019
Resolved 2 August 2019
Resolution: Vessel now has overboard valves locked and the captain is responsible for the key.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 12 June 2019 Resolved
Vessel has exposed dead end wires, multiple unauthorized splices, and unsatisfactory support of cables. Remove dead end wires in ships electrical system, and properly support cables.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 July 2019
Resolved 2 August 2019
Resolution: Unauthorized splices and dead wires have been removed. All cables appeared to have proper supports
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 12 June 2019 Resolved
Required subdivision bulkheads in way of the engine room and lazarette are not watertight due to access openings being created in them. Make the subdivision bulkheads watertight with no doors or hatches, or provide inflatable buoyant apparatus for 100% of persons allowed on board.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 July 2019
Resolved 2 August 2019
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 5 June 2018 Resolved
Alcohol testing swabs expired.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 July 2018
Resolved 17 July 2018
Resolution: Deficiency corrected to the satisfaction of the attending Coast Guard Marine Inspector.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 5 June 2018 Resolved
Fixed system and portables due for service 08 days from inspection. Operator to provide new servicing report to MI once service is complete.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 June 2018
Resolved 30 June 2018
Resolution: Deficiency corrected to the satisfaction of the Coast Guard Marine Inspector.
Communications › Alarms/Indicators › Bilge Alarm
Issued 5 June 2018 Resolved
Prove operation of visual/audible alarms on bridge for engine room bilge/high level alarms.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 July 2018
Resolved 17 July 2018
Resolution: Deficiency corrected to the satisfaction of the attending Coast Guard Marine Inspector.
Navigation › Piloting/Steering › Marine Charts
Issued 5 June 2018 Resolved
Provide current and/or updated charts for area of operation.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 June 2018
Resolved 6 June 2018
Resolution: Master sent receipt and verification of updated charts for area of operation.
Lifesaving › Lifefloat › Lifeline
Issued 5 June 2018 Resolved
Several lines on lifefloat not dark in color or uv resistant.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 July 2018
Resolved 17 July 2018
Resolution: Deficiency corrected to the satisfaction of the attending Coast Guard Marine Inspector.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 5 June 2018 Resolved
Waterlight not functional.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 July 2018
Resolved 17 July 2018
Resolution: Deficiency corrected to the satisfaction of the attending Coast Guard Marine Inspector.
Lifesaving › Lifebuoys › Serviceable
Issued 5 June 2018 Resolved
Grab lines on 24" ring buoy wasted and in need of replacement.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 July 2018
Resolved 17 July 2018
Resolution: Deficiency corrected to the satisfaction of the attending Coast Guard Marine Inspector.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 12 June 2017 Resolved
Condct servicing of fixed fire extinguishing system, to include portable extinguishers, not authorized to carry passengers until provided.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 June 2017
Resolved 16 June 2017
Resolution: See Narrative.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 12 June 2017 Resolved
Conduct renewal registration of EPIRB and update vessel specific information, restricted to no more than three (03) nautical miles from mainland shore.
Condition: Invalid
Action required: 705 - Other - as specified
Due 16 June 2017
Resolved 16 June 2017
Resolution: See Narrative.
Stability › Watertight Integrity › General
Issued 12 June 2017 Resolved
Repair engine room bilge high level alarm audio & visual, at wheelhouse, prior to carrying passengers.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 June 2017
Resolved 16 June 2017
Resolution: See Narrative.
Lifesaving › Hand Flares › Expired
Issued 12 June 2017 Resolved
Provide 02 red hand flares, restricted to operating within lakes, bays & sounds route within boundary line.
Condition: Invalid
Action required: 705 - Other - as specified
Due 16 June 2017
Resolved 16 June 2017
Resolution: See Narrative.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 12 June 2017 Resolved
Apply for a Coastwise endorsement on vessel's certificate of documentation.
Action required: 705 - Other - as specified
Due 26 June 2017
Resolved 16 June 2017
Resolution: See Narrative.
Navigation › Piloting/Steering › Marine Charts
Issued 12 June 2017 Resolved
Provide up-to-date navigation charts.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 June 2017
Resolved 16 June 2017
Resolution: See Narrative.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 12 June 2017 Resolved
Provide eye dressing kit for first aid kit.
Action required: 705 - Other - as specified
Due 16 June 2017
Resolved 16 June 2017
Resolution: See Narrative.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 12 June 2017 Resolved
Provide new retroreflective tape for three identified adult lifejackets.
Action required: 705 - Other - as specified
Due 16 June 2017
Resolved 16 June 2017
Resolution: See Narrative.
Documentation › Logs/Records › MIS Form
Issued 12 June 2017 Resolved
Provide 2016 MIS report for drug and alcohol program.
Action required: 705 - Other - as specified
Due 16 June 2017
Resolved 16 June 2017
Resolution: See Narrative.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 12 June 2017 Resolved
Provide securing device for forepeak hatch.
Action required: 705 - Other - as specified
Due 16 June 2017
Resolved 16 June 2017
Resolution: See Narrative.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 7 June 2016 Resolved
Replace in kind 02 Lifejackets.
Action required: 705 - Other - as specified
Due 7 June 2016
Resolved 7 June 2016
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 7 June 2016 Resolved
Replace retroreflective material on 08 identified lifejackets.
Action required: 705 - Other - as specified
Due 7 June 2016
Resolved 7 June 2016
Lifesaving › Lifebuoys › Stowage
Issued 7 June 2016 Resolved
Properly stow all life rafts in manner to float freely, and detach from vessel as designed.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 June 2016
Resolved 7 June 2016
Lifesaving › Lifefloat › Float-free Link
Issued 10 March 2010 Resolved
Provide weak link for float free arrangement.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 April 2010
Resolved 11 March 2010
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 10 March 2010 Resolved
Provide an anchor light.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 April 2010
Resolved 11 March 2010
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 11 March 2009 Resolved
Carbonminoxide detector required in aft bunkhouse due to engine exhaust system running through space.
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 March 2009
Resolved 10 June 2016
Resolution: Cleared by [name withheld]. 10Jun2016 - Resolved administratively. T.McGuigan
Documentation › Certificates/Documents › FCC SSL
Issued 11 March 2009 Resolved
FCC radio telephone safety certificate is faded and very difficult to read expiration date; it appears to expire Mar2009.
Due 1 April 2009
Resolved 19 March 2009
Resolution: Cleared by [name withheld].
Operations/Management › Drills/Instruction › Fire
Issued 11 March 2009 Resolved
Ensure required drill are logged quarterly as per 46 CFR185.520 and .524. Crew knowledge of emergency procedures evident to CGMI.
Due 18 March 2009
Resolved 18 March 2009
Resolution: Conducted training with VSL O/O on proper log entries.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 11 March 2009 Resolved
Ring life buoy needs float light replaced.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 March 2009
Resolution: Cleared by [name withheld].
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 11 March 2009 Resolved
Add necessary retro reflective to ring life buoys IAW 46 CFR185.604
Due 18 April 2009
Resolved 19 March 2009
Resolution: Cleared by [name withheld].
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 11 March 2009 Resolved
Fabricate and install propulsion shaft guards in engine room.
Due 18 April 2009
Resolved 14 April 2009
Resolution: Shaft guard fabricated and installed to the satisfaction of attending CGMI.
Communications › Alarms/Indicators › Bilge Alarm
Issued 11 March 2009 Resolved
Repair forward bunkhouse high level bilge water alarm.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 March 2009
Resolution: Cleared by [name withheld].
Engineering › Lubricating Oil Service System › Gauge
Issued 11 March 2009 Resolved
Repair and make operable Port engine lube oil pressure alarm.
Due 18 April 2009
Resolved 19 March 2009
Resolution: Cleared by [name withheld].
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 22 September 2008 Resolved
Remove and relocate Pressure Switch outside the engine room
Action required: 705 - Other - as specified
Resolved 4 November 2008
Resolution: Pressure switches were relocated to the aft state room
Engineering › Sea-water System (primary cooling) › Valve
Issued 22 September 2008 Resolved
Replace valve on bait pump
Action required: 705 - Other - as specified
Resolved 4 November 2008
Resolution: Verified valve were renewed
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 19 March 2008 Resolved
Move pressure switch for fixed CO2 system to location outside space [46CFR181.410(b)(i)]
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 October 2008
Resolved 4 November 2008
Resolution: Pressure switch were relocted to aft bunk room
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 19 March 2008 Resolved
Install blanks in "tank room" breaker box where breakers missing.
Action required: 705 - Other - as specified
Due 19 April 2008
Resolved 4 April 2008
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 19 March 2008 Resolved
Re-mount stern light to be seen in horizontal position.
Action required: 705 - Other - as specified
Due 19 April 2008
Resolved 4 April 2008
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 19 March 2008 Resolved
Replace worn cooling water hose on starboard generator.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 April 2008
Resolved 4 April 2008
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 19 March 2008 Resolved
Replace small piece of damaged fiberglass exhaust on starboard exhaust between pedros.
Action required: 705 - Other - as specified
Due 19 April 2008
Resolved 4 April 2008
Resolution: Replaced FRP w/ stainless steel.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 19 March 2008 Resolved
Install support for starboard exhaust in engine room.
Action required: 705 - Other - as specified
Due 19 April 2008
Resolved 4 April 2008
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 19 March 2008 Resolved
Update pubs w/ latest NTM & obtain chart of SD Bay entrance updated to latest NTM.
Action required: 705 - Other - as specified
Due 19 April 2008
Resolved 4 April 2008
Resolution: O/O obtained up-to-date chart of SD Bay & applicable NTMs for pubs. Also, SSD CID/SPI accepted electronic charts provided they are programmed w/ the latest updates.
Communications › Radio Communications › Radiotelephone Transceiver (2-27.5 MHz)
Issued 19 March 2008 Resolved
Demonstrate operation of digital selective calling (DSC) radio to include use of vessel-specific frequency.
Action required: 705 - Other - as specified
Due 19 April 2008
Resolved 4 April 2008
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 14 March 2007 Resolved
Provide corrected U.S. Coast Pilot, CG Light List for areas vessel transits (excerpts acceptable) and Rules of the Road.
Action required: 705 - Other - as specified
Due 14 April 2007
Resolved 13 April 2007
Lifesaving › Lifefloat › Netting
Issued 14 March 2007 Resolved
Repair/replace netting where torn on top lifefloat. Vessel restricted to nmt 36 persons until corrected.
Action required: 705 - Other - as specified
Due 14 April 2007
Resolved 13 April 2007
Fire Fighting › Grease Extraction Hood › General
Issued 14 March 2007 Resolved
Modify grease extraction ductwork & fan to comply w/ Sector SD CID/SPI policy #20 (Grease Extraction Hoods) applicable to vessels less than 65 ft.
Action required: 705 - Other - as specified
Due 14 September 2007
Resolved 13 April 2007
Lifesaving › Lifeboat Equipment › First Aid Kit
Issued 16 March 2006 Resolved
Replace expired items; aspirin, burn gel, iodine.
Condition: Improper/Lack of Maintenance
Due 24 March 2006
Resolved 30 March 2006
Resolution: New asprin, burn gel, and iodine found in first aid kit.
Lifesaving › Lifejacket/PFD (Type II) › Retroreflective Material
Issued 16 March 2006 Resolved
Replace or provide retro-reflective tape to two adult life jackets.
Condition: Improper/Lack of Maintenance
Due 24 March 2006
Resolved 30 March 2006
Resolution: Two new adult PFDs purchased with proper retro tape provided. Non-retro''ed PFDs removed from vessel.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 16 March 2006 Resolved
Label emergency escape hatch in lounge area.
Condition: Improper/Lack of Maintenance
Due 24 March 2006
Resolved 30 March 2006
Resolution: Emergency escape hatch found properly stenciled.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 16 March 2006 Resolved
Provide line for crewmember during man overboard evolutions.
Due 24 March 2006
Resolved 30 March 2006
Resolution: Floatable polypropylene line w/ detachable clip provided for rescue swimmer PFD.
Engineering › Diesel Engine (propulsion-electric) › Piping (exhaust)
Issued 16 March 2006 Resolved
Provide additional clamp on starboard exhaust pipe in engine room.
Condition: Improper/Lack of Maintenance
Due 24 March 2006
Resolved 30 March 2006
Resolution: Found subject exhaust pipe properly double clamped at all junctions.
Electrical › Electrical Distribution System (service) › Cable
Issued 16 March 2006 Resolved
Rewrap shore power cable.
Condition: Improper/Lack of Maintenance
Due 24 March 2006
Resolved 30 March 2006
Resolution: Owner purchased new shore tie cable.
Electrical › Electric Generation Source (service) › Metallic Enclosure/Frame
Issued 16 March 2006 Resolved
Install metal support for electrical cable in the engine room.
Due 24 March 2006
Resolved 30 March 2006
Resolution: Found proper metal cable supports installed no more than 24" on center.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 1 March 2005 Resolved
A current/updated CG light list publication is required.
Due 21 April 2005
Resolved 22 March 2005
Resolution: A new 2005 Light List was purchased.
Navigation › Piloting/Steering › US Coast Pilot
Issued 1 March 2005 Resolved
A current/updated U.S. Coast Pilot publication is required.
Due 21 April 2005
Resolved 22 March 2005
Resolution: A new 2005 Coast Pilot was purchased.
Lifesaving › Lifefloat › Lifeline
Issued 1 March 2005 Resolved
Lanyards on the vsls two (2) lifefloats & waterlight need to be replaced due to UV rot.
Due 21 April 2005
Resolved 22 March 2005
Resolution: Replaced rotted lanyards with new line.
Accommodation/Occupational Safety › Ventilation › General
Issued 1 March 2005 Resolved
Hardwire blower fan in lazerette.
Due 21 April 2005
Resolved 22 March 2005
Resolution: Hardwire installation completed.
Engineering › Sea-water System (primary cooling) › Piping
Issued 19 November 2004 Resolved
Remove PVC piping from salt water system on port engine.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 December 2004
Resolved 24 January 2005
Construction/Loadline › Hull › Longitudinal Frame
Issued 19 November 2004 Resolved
Submit repair proposals on port and starboard bow area that showed signs of fiberglass cracking.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 3 December 2004
Resolved 24 January 2005
Engineering › Bilge Water Management System
Issued 21 February 2002 Resolved
Hose for hand bilge pump missing. LEGACY COMPONENT DESC: Hose
Action required: 705 - Other - as specified
Resolved 19 March 2002
Electrical › Electric Generation Source (service)
Issued 21 February 2002 Resolved
Clean ship service generator windings. LEGACY COMPONENT DESC: Generator
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 March 2002
Resolved 21 February 2002
Accommodation/Occupational Safety › Medical/First Aid
Issued 21 February 2002 Resolved
Replace first aid kit due to expired items and broken storage box. LEGACY COMPONENT DESC: Medicine Chest
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 4 March 2002
Resolved 21 February 2002
Lifesaving
Issued 1 March 2001 Resolved
vessel needs 4 more PFDs to meet the requirements of the COI. Passengers are limited to 42 vice 46 until met.
Condition: Unknown
Due 3 April 2001
Resolved 3 April 2001
Lifesaving
Issued 1 March 2001 Resolved
Weak link for lifefloats was run improperly, not allowing painter to pay out.
Condition: Unknown
Due 12 April 2001
Resolved 12 April 2001
Lifesaving
Issued 1 March 2001 Resolved
Defective ANSUL control head for the CO2 system. Firemaster company to replace/repair. Vessel may not get underway before this item is corrected.
Condition: Unknown
Due 3 April 2001
Resolved 3 April 2001
Documentation
Issued 1 March 2001 Resolved
Provide MIS documentation for drug program.
Condition: Unknown
Due 3 April 2001
Resolved 3 April 2001
Documentation
Issued 1 March 2001 Resolved
COI not posted under transparent material in plain view of passengers.
Condition: Unknown
Due 3 April 2001
Resolved 3 April 2001
Lifesaving
Issued 1 March 2001 Resolved
Stencil escape hatch, "Escape hatch, do not block".
Condition: Unknown
Due 12 April 2001
Resolved 12 April 2001
Accommodation/Occupational Safety
Issued 1 March 2001 Resolved
port light cover missing in fwd stbd berthing compartment.
Condition: Unknown
Due 3 April 2001
Resolved 3 April 2001
Lifesaving
Issued 1 March 2001 Resolved
Stencil hydro date on EPIRB holder and provide documentation to inspectors proving hydro date.
Condition: Unknown
Due 16 April 2001
Resolved 16 April 2001
Documentation
Issued 1 March 2001 Resolved
Missing radio operators license.
Condition: Unknown
Due 12 April 2001
Resolved 12 April 2001
Lifesaving
Issued 9 March 2000 Resolved
Provide First Aid Kit.
Condition: Unknown
Due 23 April 2000
Resolved 10 April 2000
Navigation
Issued 9 March 2000 Resolved
Double Nut/Cotter Pin the steering linkages.
Condition: Unknown
Due 23 April 2000
Resolved 10 April 2000
Accommodation/Occupational Safety
Issued 9 March 2000 Resolved
Install ladder to engine room.
Condition: Unknown
Due 23 April 2000
Resolved 10 April 2000
Fire Fighting
Issued 9 March 2000 Resolved
Prove proper operation of fixed fire fighting system (Engine & Vent shutdowns.
Condition: Unknown
Due 23 April 2000
Resolved 10 April 2000
Fire Fighting
Issued 9 March 2000 Resolved
Provide Fire Buckets
Condition: Unknown
Due 23 April 2000
Resolved 28 March 2000
Engineering
Issued 9 March 2000 Resolved
Prove proper operation of Port Generator
Condition: Unknown
Due 9 March 2000
Resolved 9 March 2000
Accommodation/Occupational Safety
Issued 9 March 2000 Resolved
Provide Life Jacket donning Placard.
Condition: Unknown
Due 23 April 2000
Resolved 10 April 2000
Lifesaving
Issued 9 March 2000 Resolved
Prove proper operation of Public Address System.
Condition: Unknown
Due 23 April 2000
Resolved 10 April 2000
Engineering
Issued 9 March 2000 Resolved
Provide vent covers for engine room.
Condition: Unknown
Due 23 April 2000
Resolved 10 April 2000
Electrical
Issued 9 March 2000 Resolved
Install electrical outlet covers throughout the Vessel.
Condition: Unknown
Due 23 April 2000
Resolved 10 April 2000
Lifesaving
Issued 11 March 1999 Resolved
RE-STOW LIFEFLOAT FOR A FLOAT FREE LIFEFLOAT STOWAGE.
Condition: Unknown
Due 22 April 1999
Resolved 22 April 1999
Documentation
Issued 11 March 1999 Resolved
PROVIDE CURRENT 46CFR SUBCHAPTER "T".
Condition: Unknown
Due 22 April 1999
Resolved 22 April 1999
Fire Fighting
Issued 11 March 1999 Resolved
INSTALL FIXED FIRE FIGHTING SYSTEM AS PER CG APPROVED/ACCEPTED PLANS AND CONDUCT OPERATIONAL TEST TO THE SATISFACTION OF ATTENDING CG MARINE INSPECTOR.
Condition: Unknown
Due 11 March 1999
Resolved 11 March 1999
Fire Fighting
Issued 11 March 1999 Resolved
PROVIDE PROPER VENT CLOSURE FOR THE ENGINE ROOM NATURAL AIR VENTS.
Condition: Unknown
Due 22 April 1999
Resolved 22 April 1999
Navigation
Issued 11 March 1999 Resolved
CORRECT POSITIONING OF ANCHOR LIGHT AND STERN LIGHT (PROPER ANGLE INSTALLATION).
Condition: Unknown
Due 22 April 1999
Resolved 22 April 1999
Construction/Loadline
Issued 12 November 1998 Resolved
REPAIR/REFASTEN STRINGER IN WAY OF FORE PEAK, PORT SIDE
Condition: Unknown
Due 1 February 1999
Resolved 1 February 1999
Construction/Loadline
Issued 12 November 1998 Resolved
PROVIDE REPAIR PROPOSAL AND MAKE REPAIRS OF BOTTOM SHELL IN WAY OF PORT SIDE CHINE.
Condition: Unknown
Due 1 February 1999
Resolved 1 February 1999
Engineering
Issued 8 July 1998 Resolved
Repair faulty shift linkage on center main diesel engine. Item to be corrected prior to operating engine.
Condition: Unknown
Due 8 July 1998
Resolved 8 July 1998
Engineering
Issued 8 July 1998 Resolved
Repair / replace holed exhaust manifold (stbd) on center main diesel engine. Item to be corrected prior to operating engine.
Condition: Unknown
Due 8 July 1998
Resolved 8 July 1998
Engineering
Issued 11 March 1997 Resolved
PROPERLY REPAIR THE WET EXHAUST PIPES FOR THE PORT AND STARBOARD DIESEL ENGINE WHERE WATER IS LEAKING.
Condition: Unknown
Due 11 March 1997
Resolved 11 March 1997
Electrical
Issued 11 December 1996 Resolved
Provide a properly sized fuse or circuit breaker in the battery supply cables. Circuit protection must be located close to the batteries as per 46CFR 183.05-15.
Condition: Unknown
Due 2 January 1997
Resolved 15 January 1997
Electrical
Issued 11 December 1996 Resolved
Provide an electrical survey identifying all substandard or nonstandard circuits and a schedule to bring the electrical system in compliance.
Condition: Unknown
Due 11 December 1996
Resolved 11 December 1996
Electrical
Issued 11 December 1996 Resolved
Replace all undersized conductors and cables in the DC electrical distribution panels in the pilothouse. Minimum conductor size is 14AWG. Allcircuit breakers or fuses must not exceed maximum allowable rating of conductor size and length as per 46 CFR 183.05-45.
Condition: Unknown
Due 2 January 1997
Resolved 15 January 1997
Construction/Loadline
Issued 8 November 1996 Resolved
Submit repair proposal of rotted/split side longitudinal port side amidships at SONAR.
Condition: Unknown
Due 8 November 1996
Resolved 8 November 1996
Construction/Loadline
Issued 8 November 1996 Resolved
Install stop valve in forepeak bilge line on the after side of collision bulkhead IAW 46CFR182.25-5(d).
Condition: Unknown
Due 8 November 1996
Resolved 8 November 1996
Construction/Loadline
Issued 8 November 1996 Resolved
Repair underdeck frames where split and rotted over port main engine in engine room.
Condition: Unknown
Due 8 November 1996
Resolved 8 November 1996
Electrical
Issued 8 November 1996 Resolved
Hardwire all permanently installed electrical equipmemt with proper circuitprotection, proper wire/cable size and type.
Condition: Unknown
Due 8 November 1996
Resolved 8 November 1996
Construction/Loadline
Issued 8 November 1996 Resolved
Submit repair proposal for repair of rotted areas in both left and right center engine stringers in engine room.
Condition: Unknown
Due 8 November 1996
Resolved 8 November 1996
Construction/Loadline
Issued 11 April 1996 Resolved
RENEW FLEXABLE HOSE ATTACHED TO THE ENGINEROOM BILGE PUMP.
Condition: Unknown
Due 11 April 1996
Resolved 11 April 1996
Navigation
Issued 11 April 1996 Resolved
MAINTAIN A FILE OF LOCAL NOTICES TO MARINERS.
Condition: Unknown
Due 11 April 1996
Resolved 11 April 1996
Construction/Loadline
Issued 11 April 1996 Resolved
PROPERLY SUPPORT PORT AND STARBOARD POTABLE WATER TANKS.
Condition: Unknown
Due 11 April 1996
Resolved 11 April 1996
Construction/Loadline
Issued 11 April 1996 Resolved
CLEAN OIL AND OILY RAGS FROM THE ENGINEROOM BILGE.
Condition: Unknown
Due 11 April 1996
Resolved 11 April 1996
Electrical
Issued 11 April 1996 Resolved
PROPERLY SECURE THE WIRE RUN IN THE ENGINEROOM OVERHEAD.
Condition: Unknown
Due 11 April 1996
Resolved 11 April 1996
Lifesaving
Issued 11 April 1996 Resolved
RENEW THE WASTER WATERLIGHTS TO THE LIFEFLOATS.
Condition: Unknown
Due 23 April 1996
Resolved 23 April 1996
Navigation
Issued 11 April 1996 Resolved
PROVIDE CORRECTED NAVIGATION PUBLICATIONS FOR ROUTES TRAVELED.
Condition: Unknown
Due 11 April 1996
Resolved 11 April 1996
Deck/Cargo
Issued 16 November 1994 Resolved
TIGHTEN LOOSE MOORING CLEATS.
Condition: Unknown
Due 16 November 1994
Resolved 16 November 1994
Electrical
Issued 16 November 1994 Resolved
REBUILD BATTERY BOX.
Condition: Unknown
Due 16 November 1994
Resolved 16 November 1994
Construction/Loadline
Issued 16 November 1994 Resolved
BILGE SUCTION STRAINER MISSING.
Condition: Unknown
Due 16 November 1994
Resolved 16 November 1994
Electrical
Issued 5 April 1994 Resolved
INSTALL AMP METER FOR BOTH GENERATORS IN ACCORDANCE WITH 46CFR183.10-5(G).
Condition: Unknown
Due 5 April 1994
Resolved 5 April 1994
Electrical
Issued 5 April 1994 Resolved
INSTALL PROPER CONNECTIONS ON ALL BATTERY TERMINALS.
Condition: Unknown
Due 5 April 1994
Resolved 5 April 1994
Navigation
Issued 5 April 1994 Resolved
PROVIDE NEW/CORRECTED COAST PILOT AND LIGHT LIST.
Condition: Unknown
Due 5 April 1994
Resolved 5 April 1994
Construction/Loadline
Issued 5 November 1993 Resolved
DETERMINE EXTENT OF WASTAGE (ROT) TO ALL LONGITUDINAL DECK BEAMS IN ENGINE ROOM, SUBMIT REPAIR PROPOSAL TO LOCAL OCMI AND EFFECT REPAIRS TO THE SATISFACTION OF AN ATTENDING COAST GUARD MARINE INSPECTOR. ALL REPAIRS ARETO BE COMPLETED BY COMPLIANCE DATE LISTED BELOW.
Condition: Unknown
Due 5 November 1993
Resolved 5 November 1993
Construction/Loadline
Issued 5 November 1993 Resolved
INSTALL METALLIC SHUT-OFF VALVE AT THE COLLISION BULKHEAD FOR BILGE PIPING PENETRATING THE SAME.
Condition: Unknown
Due 5 November 1993
Resolved 5 November 1993
Navigation
Issued 27 April 1993 Resolved
PROVIDE CORRECTED CHART OF NORMAL AREA OF OPERATION AND DEMONSTRATE ABILITYTO UPDATE CHART AS NEEDED.
Condition: Unknown
Due 27 April 1993
Resolved 27 April 1993
Accommodation/Occupational Safety
Issued 27 April 1993 Resolved
PROVIDE PLACARD FOR EACH HEAD STATING OPERATING INSTRUCTIONS FOR TOILET FLUSHING VALVE.
Condition: Unknown
Due 27 April 1993
Resolved 27 April 1993
Construction/Loadline
Issued 27 April 1993 Resolved
ENSURE THAT ALL BILGE MANIFOLD VALVES WORK PROPERLY.
Condition: Unknown
Due 27 April 1993
Resolved 27 April 1993
Lifesaving
Issued 27 April 1993 Resolved
PLACE BATTENS BETWEEN LIFE FLOATS.
Condition: Unknown
Due 27 April 1993
Resolved 27 April 1993
Fire Fighting
Issued 27 April 1993 Resolved
ENSURE THAT ALL FIRE EXTINGUISHERS ON BOARD HAVE BEEN PROPERLY SERVICED (WITHIN THE LAST YEAR) AND HYDROSTATICALLY TESTED (WITHIN THE LAST TWELVE YEARS). ENSURE THAT SPARE EXTINGUISHERS REMAIN ON BOARD, PROPERLY STOWED, UNTIL REQUIREMENT MET.
Condition: Unknown
Due 27 April 1993
Resolved 27 April 1993
Lifesaving
Issued 27 May 1992 Resolved
REPAIR/REPLACE THE 3 UNACCEPTED ADULT LIFEJACKETS PRIOR TO CARRYING 43 ADULT PASSENGERS._x001C_
Condition: Unknown
Due 27 May 1992
Resolved 27 May 1992
Electrical
Issued 27 May 1992 Resolved
INSTALL DRIP SHIELDS OVER BOTH BATTERY CHARGERS.
Condition: Unknown
Due 27 May 1992
Resolved 27 May 1992
Fire Fighting
Issued 27 May 1992 Resolved
HAVE ONE B-II FIRE EXTINGUISHER RECHARGED.
Condition: Unknown
Due 28 May 1992
Resolved 28 May 1992
Navigation
Issued 16 April 1991 Resolved
PROVIDE UP-TO-DATE CHARTS FOR AREA OF OPERATION, CURRENT LIGHT LIST, AND COPY OF RULES OF THE ROAD.
Condition: Unknown
Due 16 April 1991
Resolved 16 April 1991
Electrical
Issued 16 April 1991 Resolved
PROVE PROPER OPERATION OF STARBOARD GENERATOR.
Condition: Unknown
Due 16 April 1991
Resolved 16 April 1991
Electrical
Issued 16 April 1991 Resolved
PROVIDE EMERGENCY LIGHTING FOR AFT PASSENGER COMPARTMENT.
Condition: Unknown
Due 16 April 1991
Resolved 16 April 1991
Electrical
Issued 16 April 1991 Resolved
PROVIDE COVER FOR OPEN HOLE IN WHEELHOUSE BREAKER PANEL.
Condition: Unknown
Due 16 April 1991
Resolved 16 April 1991
Lifesaving
Issued 10 April 1990 Resolved
PROVIDE 3 ADDITIONAL ADULT PFD'S REQUIRED FOR COASTWISE ROUTE. VESSEL IS LIMITED TO 43 TOTAL PERSONS UNTIL THIS REQUIREMENT IS MET.
Condition: Unknown
Due 10 April 1990
Resolved 10 April 1990
Lifesaving
Issued 10 April 1990 Resolved
PROVIDE TEMPORARY PFD PLACARD FOR COASTWISE ROUTE.
Condition: Unknown
Due 10 April 1990
Resolved 10 April 1990
Navigation
Issued 10 April 1990 Resolved
REPLACE WORN BOLT STEERING RAM.
Condition: Unknown
Due 10 April 1990
Resolved 10 April 1990
Navigation
Issued 10 April 1990 Resolved
SECURE STEERING LINKAGE WITH PIN OR DOUBLE NUT.
Condition: Unknown
Due 10 April 1990
Resolved 10 April 1990
Documentation
Issued 9 May 1989 Resolved
PROPERLY POST VESSEL'S STABILITY LETTER IN PILOT HOUSE UNDER TRANSPARENT MATERIAL PRIOR TO OPERATION.
Condition: Unknown
Due 9 May 1989
Resolved 9 May 1989
Construction/Loadline
Issued 9 May 1989 Resolved
CLEAN AND TREAT DRY ROT IN OVERHEAD IN ENGINE ROOM.
Condition: Unknown
Due 9 May 1989
Resolved 9 May 1989
Documentation
Issued 9 May 1989 Resolved
PROPERLY POST OIL POLLUTION PLACARD PRIOR TO OPERATION.
Condition: Unknown
Due 9 May 1989
Resolved 9 May 1989
Construction/Loadline
Issued 26 April 1989 Resolved
PROVIDE CAPTURE CHAIN FOR FORWARD WATERTIGHT HATCH.
Condition: Unknown
Due 26 April 1989
Resolved 26 April 1989
Deck/Cargo
Issued 26 April 1989 Resolved
REPLACE BAIT PUMP SEA VALVE.
Condition: Unknown
Due 26 April 1989
Resolved 26 April 1989
Fire Fighting
Issued 26 April 1989 Resolved
SERVICE AND HYDROSTATICALLY TEST ALL EXTINGUISHERS WITH LOW PRESSURE READINGS. EXTINGUISHERS TO BE ON BOARD AND FULLY CHARGED BEFORE CARRYING PASSENGERS.
Condition: Unknown
Due 26 April 1989
Resolved 26 April 1989
Construction/Loadline
Issued 27 June 1988 Resolved
RESTORE FUMETIGHTNESS OF DOOR BETWEEN ACCOMMODATION AND F.O. TANK COMPARTMENTS TO LEVEL AGREED IN NEW CONSTRUCTION PER ATTACHED LETTER.
Condition: Unknown
Due 27 June 1988
Resolved 27 June 1988
Electrical
Issued 19 April 1988 Resolved
PROVE PROPER OPERATION OF STBD GENERATOR.
Condition: Unknown
Due 19 April 1988
Resolved 19 April 1988
Navigation
Issued 19 April 1988 Resolved
DOUBLE NUT OR PROVIDE OTHER POSITIVE MEANS OF SCURING ALL STEERING LINKAGE.
Condition: Unknown
Due 19 April 1988
Resolved 19 April 1988
Electrical
Issued 19 April 1988 Resolved
PROVE PROPER OPERATION OF EMERGENCY LIGHTING SYSTEM.
Condition: Unknown
Due 19 April 1988
Resolved 19 April 1988
Lifesaving
Issued 19 April 1988 Resolved
REPLACE PORT LIFE FLOAT-FREE LINK WITH ONE SUITABLE FOR 12 PERSONS.
Condition: Unknown
Due 19 April 1988
Resolved 19 April 1988
Lifesaving
Issued 19 April 1988 Resolved
PROVIDE 1 ADDITIONAL ADULT PFD; NUMBER OF PERSONS ON BOARD LIMITED TO 45 UNTIL THIS ITEM IS COMPLETED.
Condition: Unknown
Due 19 April 1988
Resolved 19 April 1988
Accommodation/Occupational Safety
Issued 19 April 1988 Resolved
PROVIDE 100 PSI RELIEF VALVE FOR HOT WATER HEATER.
Condition: Unknown
Due 19 April 1988
Resolved 19 April 1988
Accommodation/Occupational Safety
Issued 19 April 1988 Resolved
DOUBLE HOSE CLAMP FUEL TANK VENT AND BAIT PUMP SUCTION.
Condition: Unknown
Due 19 April 1988
Resolved 19 April 1988
Electrical
Issued 19 April 1988 Resolved
PROPERLY SECURE ENGINE SENSOR AND OTHER LOOSE WIRES.
Condition: Unknown
Due 19 April 1988
Resolved 19 April 1988
Electrical
Issued 19 April 1988 Resolved
REMOVE DEAD-END WIRES ON TRANSOM IN LAZARETTE AND IN THE ENGINEROOM IN THE STARBOARD GEN REGULATOR BOX. REINSTALL COVERS ON ALL ELECTRICAL PANELS.
Condition: Unknown
Due 19 April 1988
Resolved 19 April 1988
Documentation
Issued 21 May 1987 Resolved
PROVIDE MARINE DOCUMENT.
Condition: Unknown
Due 21 May 1987
Resolved 21 May 1987
Lifesaving
Issued 21 May 1987 Resolved
PROVIDE 05 ADDITIONAL ADULT LIFE PRESERVERS
Condition: Unknown
Due 21 May 1987
Resolved 21 May 1987
Lifesaving
Issued 28 May 1986 Resolved
PROVIDE ADDITIONAL RETRO-REFLECTIVE TAPE ON SEVENTEEN (17) CHILD PFD'S SO THAT EACH SIDE HAS SIXTY-FOUR (64) SQUARE INCHES.
Condition: Unknown
Due 28 May 1986
Resolved 28 May 1986
Navigation
Issued 28 May 1986 Resolved
MAKE STARBOARD RUNNING LIGHT VISABLE THROUGH ENTIRE REQUIRED RANGE.
Condition: Unknown
Due 28 May 1986
Resolved 28 May 1986
Construction/Loadline
Issued 28 May 1986 Resolved
REPLACE BROKEN WINDOW ON STARBOARD AFTER SIDE OF HOUSE.
Condition: Unknown
Due 28 May 1986
Resolved 28 May 1986
Lifesaving
Issued 28 May 1986 Resolved
FREE UP EMERGENCY ESCAPE HATCH FOR FOWARD PASSENGER BERTHING.
Condition: Unknown
Due 28 May 1986
Resolved 28 May 1986
Fire Fighting
Issued 28 May 1986 Resolved
PROVIDE VESSEL WITH OPERABLE FIVE (5) GPM HAND FIRE AND BILGE PUMP.
Condition: Unknown
Due 28 May 1986
Resolved 28 May 1986
Lifesaving
Issued 28 May 1986 Resolved
PROVIDE VESSEL WITH SIX (06) ADDITIONAL ADUCT PFD'S UNTIL PFD'S ARE ONBOARD, TOTAL PERSONS ONBOARD IS RESTRICTED TO FORTY (40).
Condition: Unknown
Due 28 May 1986
Resolved 28 May 1986
Navigation
Issued 25 March 1986 Resolved
TIGHTEN UP RAM BRACKET ON STEERING SYSTEM
Condition: Unknown
Due 25 March 1986
Resolved 25 March 1986
Engineering
Issued 7 May 1985 Resolved
RE-INSTALL THE SALTWATER COOLOING HOSE FOR THE CENTER MAIN ENGINE EXHAUST SYSTEM.
Condition: Unknown
Due 7 May 1985
Resolved 7 May 1985
Construction/Loadline
Issued 7 May 1985 Resolved
PROPERLY BLANK THE TROUGH HULL LOCATED BELOW THE FOREWARD END OF THE STBD MAIN ENGINE.
Condition: Unknown
Due 7 May 1985
Resolved 7 May 1985
Electrical
Issued 7 May 1985 Resolved
PROVIDE A PROPER COVER FOR THE JUNCTION BOX LOCATED ON THE STARBOARD SIDE AFTER ENGINE ROOM BULKHEAD.
Condition: Unknown
Due 7 May 1985
Resolved 7 May 1985
Electrical
Issued 7 May 1985 Resolved
PROVIDE GLOBES AND GUARDS FOR THE ENGINEROOM LIGHTING FIXTURES.
Condition: Unknown
Due 7 May 1985
Resolved 7 May 1985

Casualty record · 4

4 June 2003Routine · role: Involved in a Marine Casualty · 1 dead · activity 1810376
6 June 2005Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 2385354
6 June 2005Routine · role: Involved in a Marine Casualty · activity 2389023
9 August 2007Routine · role: Involved in a Marine Casualty · activity 3110785
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

INDIAN (2003–2007). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.