MAURY USCG vessel records
← All vessels

LA PESCA

LA PESCA is a 1970 passenger vessel (inspected). The Coast Guard has recorded 30 inspections since 2016, most recently in May 2026, along with 88 deficiencies, 1 operational control and 1 casualty investigation in 2009.

Records from 2009 to 2026. Most recent: inspection, 5 May 2026.

Built
1970
Last inspected
5 May 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 5 May 2026
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDJ5455
Flag
UNITED STATES
Maury page id
psix-46586

Documentation record

Registered dimensions (L × B × D)71.2 ft × 22.5 ft × 10.0 ft
Registered tonnagegross 99 / net 67
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTELEDYNE SEWART SEACRAFT · BERWICK LA, UNITED STATES · built 1970
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portPORT ARANSAS, TX
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 29 April 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it99 - Regulatory (Subpart C or D), Gross Ton
67 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 30

5 May 2026 Administrative Inspection · Internal Structural Exam · Vessel Attendance · Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8328272
11 March 2025 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8092158
14 January 2025 Examination of Repairs · Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8063648
29 March 2024 Annual Inspection · Internal Structural Exam · Deficiency Check · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7887056
7 September 2023 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7789370
9 May 2023 In-Service Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7685435
21 March 2023 Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7654447
28 February 2023 Drydock Exam · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7617052
4 January 2023 COI Inspection · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7616434
19 December 2022 Deficiency Check · In-Service Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7611039
12 October 2022 Deficiency Check · Administrative Inspection · In-Service Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7576149
22 September 2022 Damage Survey · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7564169
2 March 2022 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7404769
15 October 2021 In-Service Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7333391
5 March 2021 Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7150850
8 February 2021 Plan Review "T" Boat
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7188490
27 January 2021 Drydock Exam · Internal Structural Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7131562
21 April 2020 Annual Inspection · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6941764
7 October 2019 Administrative Inspection · In-Service Inspection · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6830193
2 October 2019 Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6826740
23 July 2019 In-Service Inspection · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6759900
17 July 2019 Damage Survey
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6753647
3 May 2019 Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6676335
6 February 2019 In-Service Inspection · Drydock Exam · Examination of Repairs · Deficiency Check · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6620882
8 February 2018 Internal Structural Exam · In-Service Inspection · COI Inspection · DAPI Audit · Deficiency Check · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6347745
18 September 2017 Administrative Inspection · Damage Survey · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6281514
11 May 2017 Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6142908
30 January 2017 In-Service Inspection · Internal Structural Exam · Hull Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6076171
15 August 2016 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5973206
11 May 2016 Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5873250

Deficiency record · 88

10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 5 May 2026 Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. MI observed Port/STBD Red/Green Nav Lights inoperable. Crew must fix lights prior to night operations.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 May 2026
Resolved 6 May 2026
Resolution: Vessel rep sent pictures of navigation lights in working order.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 5 May 2026 Resolved
Penetrations and openings in watertight bulkheads must—Have means to make them watertight. MI observed cable penetration in Port side lazarette bulkhead that was not water tight. Crew must make water tight.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 May 2026
Resolved 6 May 2026
Resolution: Captain sent pictures of through bulk head penetrations properly sealed and water tight.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 5 May 2026 Resolved
Portable fire extinguishers must be located so that they are clearly visible and readily accessible from the space being protected. The installation and location must be to the satisfaction of the Officer in Charge, Marine Inspection. MI observed portable fire extinguisher mounting bracket completely rusted out. Replace bracket to satisfaction of marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 May 2026
Resolved 18 May 2026
Resolution: Captain sent photo of new fire extinguisher bracket.
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 5 May 2026 Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection. MI observed 02 bunk space lights without protective lenses with exposed wiring.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 May 2026
Resolved 18 May 2026
Resolution: Captain sent photos of repaced operable accomodation bedside lamps/lights.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 8 April 2025 Resolved
Each battery used in lifesaving equipment except inflatable survival craft equipment, must be replaced during the annual inspection if the expiration date of the battery has passed. Waterlight batteries that required lithium batteries had incompatible batteries due to the manufacturers disclaimer on the external container. Replace waterlight batteries. 46 CFR 185.726(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2025
Resolved 22 April 2025
Resolution: Compatible batteries confirmed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 April 2025 Resolved
Each life jacket must be marked with Type 1 retro reflective material approved in 46 CFR 164.018 or other standard specified by the Commandant. Child life jacket retro material was excessively worn. Refit with new retro material to the satisfaction of the Marine inspector. 46 CFR 185.604(h)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2025
Resolved 22 April 2025
Resolution: Child life jackets retro refitted.
09 - Working and Living Conditions › 091 - Living Conditions › Sleeping room
Issued 8 April 2025 Resolved
All mattresses must comply with U.S. Department of Commerce "standards for mattress Flammability FF 4-72.16, 16 CFR part 1632, subpart A and not contain polyurethane foam. Two foam mattresses were observed. Replace for fire-retardant mattresses to the satisfaction of Marine Inspector. 16 CFR 171.114(a)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2025
Resolved 22 April 2025
Resolution: Verified all mattresses that did not meet required fire rating were removed from vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 1 May 2024 Resolved
If both of the required fixed power bilge pumps are electrically driven, two generators shall be required. The port generator is not operational. 46 CFR 183.05-10
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 May 2024
Resolution: The port generator fuel injectors are installed and functioning properly
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 1 May 2024 Resolved
All vessels must have navigation lights that are in compliance with the International and Inland Navigation Rules. The forward mast light and all around light are not illuminated at a close distance. 46 CFR 183.420 Vessel is limited to daylight operations.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 6 May 2024
Resolution: The lights have been satisfactorily replaced.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 1 May 2024 Resolved
Penetrations and openings in watertight bulkhead must have means to make them watertight. The watertight bulkhead aft the collision bulkhead has a cable run penetration with no packing gland or filler. 46 CFR 171.114(a)(2)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 May 2024
Resolution: The penetration was filled in with fire retardant foam.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 May 2024 Resolved
Hose end fittings must comly with SAE J-1475. The fuel hose fittings connected to the filters are 50% wasted. 46 CFR 182.720(a)(1)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 May 2024
Resolution: Fittings replaced.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 May 2024 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards. 46 CFR 183.200(b)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 May 2024
Resolution: The battery post with 6 leads was properly reconfigured.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 September 2023 Resolved
On vessels described by 46 CFR 175.110(d) of this chapter, a passenger safety bill must be posted by the master in each cabin or stateroom, and in passenger accommodation spaces. Vessel did not have a passenger safety bill. Create and post the passenger safety bill to the satifcation of the attending Coast Guard Marine Inspector. 46 CFR 185.515
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 September 2023
Resolution: Created passenger safety bill and posted.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 7 February 2023 Resolved
The bilge pipe piercing the collision bulkhead shall be fitted with a screw-down valve located on the forward side of the collision bulkhead and operable from above the weather deck. In lieu thereof, a screw-down valve without a reach rod may be fitted to the bilge line on the after side of the collision bulkhead if it is readily accessible under service conditions. Suction point forward of the forward collision bulkhead although not required, was unable to obtain suction with valve open or closed. Repair to the satisfaction of the attending MI. - 46CFR182.25-5(d)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 March 2023
Resolved 23 March 2023
Resolution: MI's verified deficiency was corrected.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 February 2023 Resolved
All vessels shall be provided with a hand operated portable fire pump having a capacity of at least 5 gallons per minute. This fire pump shall be equipped with suction and discharge hose suitable for use. No suction or discharge hose available. Replace to the satisfaction of the attending MI. - 46CFR181.10-5(a)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 March 2023
Resolved 10 March 2023
Resolution: Replaced to the satisfaction of the attending MI.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 7 February 2023 Resolved
Radio transmitting and receiving installations shall be as set forth in the regulations of the FCC. Installed NAVTEX is disconnected and does not work. Repair to the satisfaction of the attending MI. - 46CFR184.25-1(a)
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 7 February 2023
Resolution: Vessel crew provided vessel's handheld unit with the functionality required.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 7 February 2023 Resolved
Vessel shall carry 6 hand red flare and 6 hand orange smoke or 12 hand combination flare and smoke distress signals. 01 hand combination flare and smoke distress signal was expired. Replaced while on board. - 46CFR180.35-5
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 7 February 2023
Resolution: The missing flare was replaced prior to completion of USCG inspection.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 7 February 2023 Resolved
The station bill required by paragraph (a) of this section must set forth the special duties and duty station of each crew member for various emergencies. The station bill did not set forth the special duties as required. Repair to the satisfaction of the attending marine inspector. - 46CFR185.514(b)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 March 2023
Resolved 10 March 2023
Resolution: Mounted station bill to the satisfaction of the attending MI.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 7 February 2023 Resolved
At each initial and subsequent inspection for certification, the marine inspector shall require that all observed unsafe practices and hazardous situations be corrected. One crew mattress is not constructed with flame retardant material. Rectify to the satisfaction of the attending marine inspector. - 46CFR176.25-50(a)
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 March 2023
Resolved 10 March 2023
Resolution: Foam mattress removed from vessel.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 7 February 2023 Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection. Cabling in the engine room for engine controls are not installed with metal supports spaced not more than 610 millimeters (24 inches) apart. Rectify to the satisfaction of the attending marine inspector. - 46CFR183.01-15(a)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 March 2023
Resolved 10 March 2023
Resolution: All cabling properly mounted.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 7 February 2023 Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection. There are three loose wires under the bridge console. Rectify to the satisfaction of the attending marine inspector. - 46CFR183.01-15(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 March 2023
Resolved 10 March 2023
Resolution: Wiring capped to the satisfaction of the attending MI.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 February 2023 Resolved
Minimum number of portable fire extinguishers required shall be as determined by the Officer in Charge, Marine Inspection in accordance with Table 181.30-1(a). The fire extinguisher servicing chart had one extra 80-BC fire extinguisher which was not serviced and is now removed from the vessel. - 46CFR181.30-1(a)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 7 February 2023
Resolution: The extra, unserviced extinguisher was removed from the vessel.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 23 December 2022 Resolved
Fire Detection - vessels described in 46 CFR 175.110(c) must have an interconnected fire detection system in compliance with 181.450 installed in all enclosed areas where passengers and crew have routine access, including accomadations and machinery spaces. Vessel is in the process of installation of the approved system. No restrictions are implemented. Install and test to the satisfaction of the attending Marine Inspector. 46 CFR 181.405(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 January 2023
Resolved 25 January 2023
Resolution: Installed and tested sat.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 23 December 2022 Resolved
Alarms - Vessels described by 46 CFR 175.110(d) must install a device to ensure the wakefulness of the watchman, remain operable during night time watch and be arranged to cover passenger accomadations, common areas and spaces with potential hazards. Vessel is currently installing system, no restrictions are implemented. Install and test to the satisfaction of the attending Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 January 2023
Resolved 25 January 2023
Resolution: Installed and tested sat.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 3 November 2022 Resolved
Spaces containing machinery shall be fitted with adequate dripproof ventilators, trucks, louvers, etc. to provide sufficient air for proper operations of main engine and auxiliary engines. Engine Room Exhaust fan housing found covered in accumulated oil. Clean Engine Room Exhaust fan housing to the satisfaction of an attending marine inspector. 46CFR182.20-45
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 November 2022
Resolution: Cleaned exhaust fan.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 3 November 2022 Resolved
Fire hoses shall be a lined commercial fire hose that conforms to underwriters' Laboratories, Inc. 2. The starboard Fire Station hose labeled #2 was found worn in multiple areas through the external sheathing. Replace to the satisfaction of an attending marine inspector. 46 CFR 181.15-10
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 November 2022
Resolution: Replaced firehose.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 3 November 2022 Resolved
Each survival craft required on a vessel must meet one of the following: For a buoyant apparatus -approved under approval series 160.01. The nameplate must contain the name of the manufacturer, lot designation or serial number, approval number, dimensions, and number of person capacity. Life float placards were found missing or painted over. Ensure that the placards are made visible to the satisfaction of an attending Coast Guard Marine Inspector. 705c within 60 days 46 CFR 180.200(a)(4)
Action required: 705 - Other - as specified
Due 2 January 2023
Resolved 19 December 2022
Resolution: Provided measurements.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 3 November 2022 Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers.4. Life Jacket donning instructions were not found on-board for the current types provided on-board. Post life jacket donning instructions for the types present on board to the satisfaction of an attending Coast Guard Marine Inspector. 46 CFR 185.516(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 November 2022
Resolution: Posted correct donning instructions.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 3 November 2022 Resolved
Each vessel must meet the applicable requirements in Sub-chapter S of this chapter. 46 CFR 170.255(b) Class 1 doors are permitted within passenger, crew, and working spaces. Ensure the gasket for the watertight door in the lower accommodation space is a watertight gasket to the satisfaction of an attending Coast Guard Marine Inspector. 705c within 60 days 46 CFR 177.13-1
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 2 January 2023
Resolved 6 December 2022
Resolution: Provided documentation for gasket on class 1 door.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 November 2022 Resolved
Except as provided otherwise in this subpart, all electrical equipment shall be drip-proof protected. Mild water intrusion was found on the overhead of the main deck accommodation space over electrical installations. Repair to satisfaction of an attending Coast Guard Marine Inspector. 46 CFR 183.10-10
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 November 2022
Resolution: Correctly wired outlets.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 3 November 2022 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected. Ensure engine oils including hydraulic and lube oil are stored outside of the berthing/accommodation areas. 46 CFR 176.830 (a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 November 2022
Resolution: Removed combustible/flammable liquids.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 November 2022 Resolved
All electrical installation shall be to the satisfaction of the Officer IN Charge, Marine Inspection. Ensure all electrical panel boxes are properly labeled. All outlet boxes are properly mounted,grounded and wired correctly to the satisfaction of the attending Coast Guard Marine Inspector. 46 CFR 183.01-15 (a)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 November 2022
Resolution: Wired correctly
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 November 2022 Resolved
A vessel must be operated in accordance with applicable laws and regulations and in such a manner as to afford adequate precaution against hazards that might endanger the vessel and the persons being transported. Port Main Engine shaft packing gland found excessively leaking. Crew adjusted the packing gland and excessive leaking was eliminated. 46 CFR 185.100
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 9 November 2022
Resolution: Tightened packing gland seals.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 3 November 2022 Resolved
Each item of survival craft equipment must be of good quality, and efficient for the purpose it is intended to serve. Life float was found with a wasted support line for the interior netting. Brand new support line was installed. 46 CFR 180.175(a)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 9 November 2022
Resolution: Installed new lines
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 November 2022 Resolved
All electrical installation shall be to the satisfaction of the Officer IN Charge, Marine Inspection. Outlet was found improperly mounted in the lower accommodation space. Outlet was reinstalled and properly mounted. 46 CFR 183.01-15 (a)
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Resolved 9 November 2022
Resolution: Installed new outlet cover on.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 4 April 2022 Resolved
Prior to the Carriage of Passengers. On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces: A space with a through-hull fitting below the deepest load waterline, such as a lazarette. Bilge high level alarm did not indicate a visual and audible alarm at the operating station. 46 CFR 182.530(a)(1)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 7 April 2022
Resolved 6 April 2022
Resolution: Lazarette bilge alarm wiring was replaced. Alarm was tested and visual and aubible alarms were present at the operating station.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 4 April 2022 Resolved
Each stowage container for life jackets must not be capable of being locked. If practicable, the container must be designed to allow the life jacket to float free. Life jackets were restricted by a latch and were not able to float free. 46 CFR 180.78(a)(1)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 May 2022
Resolved 13 April 2022
Resolution: Latches and wasted covers were removed.
09 - Working and Living Conditions › 091 - Living Conditions › Sleeping room
Issued 4 April 2022 Resolved
All mattresses must comply with either: The U.S. Department of Commerce "Standard for Mattress Flammability" and not contain polyurethane foam. Multiple mattresses in passenger accommodation were old and unserviceable. 46 CFR 177.405(g)(1)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 May 2022
Resolved 13 April 2022
Resolution: 10 new mattresses were delivered and installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 April 2022 Resolved
Electrical equipment exposed to the weather must be watertight. Multiple topside junction boxes and electrical conduit were wasted, exposing electrical equipment to water intrusion. 46 CFR 183.210(b)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 May 2022
Resolved 13 April 2022
Resolution: Exposed electrical was repaired with new junction boxes and fittings.
09 - Working and Living Conditions › 091 - Living Conditions › Pipes, wires (insulation)
Issued 4 April 2022 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Hydraulic piping for anchor operation was found leaking into the crew accommodation space. 46 CFR 182.100
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 May 2022
Resolved 13 April 2022
Resolution: Hydraulic fitting for anchor operation had been tightened and renewed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 4 April 2022 Resolved
A vessel must be provided with a satisfactory arrangement for draining any watertight compartment under all practicable conditions. Bilge system did not satisfactorily pump until the check valve was unclogged. Vessel rep opened and cleaned check valve. 46 CFR 182.500
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 4 May 2022
Resolved 5 April 2022
Resolution: Bilge system check valve was unclogged, allowing the bilge suction to operate satisfactorily.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 March 2021 Resolved
Distribution panels and switchboards shall be totally enclosed. The underside of the distribution panel and switchboard have uninsulated openings. Ensure panel and switchboards are totally enclosed. 46 CFR 183.30-10
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 April 2021
Resolved 14 May 2021
Resolution: Distribution panel was repaired and all opening were covered.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 March 2021 Resolved
Distribution panel shall be in proper operating condition, safe electrical condition, and fir for the service intended. Distribution panel shows signs of excessive corrosion. Multiple layers of paint masking exfoliation corrosion. Bottom of front panel, top and bottom of panel are wasted. 46 CFR 176.25-15
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 April 2021
Resolved 14 May 2021
Resolution: Front door replaced, top and bottom of distribution panel were repaired.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 9 March 2021 Resolved
The Marine Inspector shall examine and test all UPV to the extent necessary to determine the their condition is satisfactory and that they are fit for the service for which intended. Mounting feet and support brackets for the UPV,s show signs of corrosion. Remove paint and corrosion to examine need for repair or replacement. 46 CFR 176.25-32
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 April 2021
Resolved 14 May 2021
Resolution: Unfired pressure vessels were removed from vessel. Vessel will no longer have UPV's.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 March 2021 Resolved
All electrical installations shall be to the satisfaction of the [name withheld] light fixture in machinery space is loosely hung. Secure light fixture. 46 CFR 183.01-15
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 April 2021
Resolved 14 May 2021
Resolution: Light fixture was repaired and securely hung.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 March 2021 Resolved
All electrical installations shall be to the satisfaction of the OCMI. In the machinery space, port side light fixture, wire glad leading up to explosion proof and intrinsically safe light fixture is exposed. Repair or replace to ensure installment is fit for the service intented. 46 CFR 183.01-15
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 April 2021
Resolved 14 May 2021
Resolution: Wire gland was repaired.
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 9 March 2021 Resolved
At each inspection for certification and re inspection the marine inspector shall examine the bilges and other spaces to see that there is no accumulation of oil or other matter which might create a fire hazard. Excessive oil and soot build up found in machinery space. Clean and remove all traces of oil and residue. 46 CFR 176.25-50
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 March 2021
Resolved 24 May 2021
Resolution: Engine room was cleaned to the crews best ability. Cleanliness of engine room is SAT.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 8 October 2019 Resolved
All emergency exits used as means of escape must be marked on both sides in clearly legible letters at least 2 inches high: EMERGENCY EXIT, KEEP CLEAR. Vessel must label WTD between crew and passenger accomodations.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 October 2019
Resolved 17 October 2019
Resolution: Vessel marked emergency escapes.
04 - Emergency Systems › N/A - No Subsystem › Location of emergency installations
Issued 8 October 2019 Resolved
The master and crew must have mounted at the operating station emergency instructions containing actions to be taken in the event of fire, heavy weather, or man overboard. Vessel does not have instructions posted.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 October 2019
Resolved 17 October 2019
Resolution: Vessel posted instructions.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 8 October 2019 Resolved
A hinged watertight door must be fitted with indicator lights at the operating station showing whether the door is open or closed. Indicator light is not operational.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 October 2019
Resolved 17 October 2019
Resolution: Light was repaired.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 23 July 2019 Resolved
AIS Class B Device. Use of a Coast Guard type-approved AIS Class B device in lieu of an AIS Class A device is permissible on the following vessels if they are not subject to pilotage by other than the vessel Master or crew: Vessels certified to carry less than 150 passengers, and that do not operate in a Vessel Traffic Service area, and do not operate at speeds in excess of 14 knots. Vessel is not currently configured with AIS. Vessel is granted 30 days (8/23/19) to install and prove proper operation of an AIS Class B system to an attending CG Marine Inspector.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 August 2019
Resolved 2 October 2019
Resolution: Due to scheduling conflicts, the date of inspection was later than the date which the vessel complied with the 835. Vessel fitted with a Vesper Marine XB-6000 Class B AIS. System tests all satisfactory.
Engineering › Steering Gear System › Rudder Stock
Issued 8 February 2018 Resolved
Port rudder post key way worn.rounded reducing travel of rudder post key. 46 CFR 182.30-1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 February 2018
Resolved 14 February 2018
Resolution: Replaced port rudder key.
Engineering › Bilge Water Management System › Pump
Issued 8 February 2018 Resolved
Vessel is equipped with one fixed power bilge pump and two submersible electric pumps. Vessels over 65 feet in length are required to have two fixed power bilge pumps which are self-priming and permanently connected to the bilge main. Submit plan proposal and install second fixed power pump to the satisfaction of the attending USCG Marine Inspector.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 15 March 2018
Resolved 6 March 2018
Resolution: Verified fire pump can be used as secondary bilge pump via operational test.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 19 September 2017 Resolved
Vessel reported damaged centerline shaft and Propeller. Inspectors may require any part of propeller shafting to be drawn for examination.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 22 September 2017
Resolved 21 September 2017
Resolution: Shaft and propeller were repaired at machine shop and installed to the satisfaction of attending marine inspector.
Engineering › Fuel Oil Service System › Hose
Issued 11 May 2017 Resolved
Fuel hoses for fuel return on all 03 main deisel engines were routed through areas of moving machinery and hot surfaces. Flexible hoses must be protected from mechanical damage. 46CFR182.720(e)(3)(ii)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 May 2017
Resolution: Center MDE fuel return line replaced with new. All 3 MDE fuel return lines rerouted, properly secured and protected from rotating machinery and hot surfaces.
Engineering › Fuel Oil Service System › Valve, Control
Issued 11 May 2017 Resolved
Fuel shutoff valve labelling is present for a shutoff valve that has been removed. Remove fuel shutoff valve labelling for shutoff valve which is no longer operable. 46CFR185.30-20
Action required: 705 - Other - as specified
Due 18 May 2017
Resolved 12 May 2017
Resolution: markings removed for fuel shut off valve that was removed.
Engineering › Fuel Oil Service System › Valve
Issued 11 May 2017 Resolved
Fuel shutoff valve is not labelled with direction of closure. Fuel shutoff valves must be labelled with direction of closure. 46CFR185.30-20
Action required: 705 - Other - as specified
Due 18 May 2017
Resolved 12 May 2017
Resolution: marking posted indicating operation of valve.
Deck/Cargo › Holds/Tanks › Hatch
Issued 11 May 2017 Resolved
Escape hatches are not labelled. Emergency exits and escape hatches must be labelled. 46CFR185.30-15
Action required: 705 - Other - as specified
Due 18 May 2017
Resolved 12 May 2017
Resolution: emergency and escape hatches properly marked.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 11 May 2017 Resolved
Hatch covers are not attached to the hatch frame or coaming. Hatch covers must be attached to prevent loss. 46CFR171.124(b)(2)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 June 2017
Resolved 12 May 2017
Resolution: attached hatch covers with cable to prevent loss.
Deck/Cargo › Holds/Tanks › Hatch
Issued 11 May 2017 Resolved
Watertight hatches are not labelled. Watertight hatches must be labelled in 1-inch lettering. 46CFR185.30-25
Action required: 705 - Other - as specified
Due 18 May 2017
Resolved 12 May 2017
Resolution: watertight hatches properly labelled.
Engineering › Steering Gear System › Ram
Issued 11 May 2017 Resolved
The port side rudder stop for main steering has a cracked weld. The vessel must be provided with a suitable steering apparatus. 46CFr182.30-1
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 11 June 2017
Resolved 12 May 2017
Resolution: Cracked weld was gouged and re-welded.
Electrical › Lighting (service) › Lighting Fixture
Issued 11 May 2017 Resolved
Lighting fixture above middle MDE has been damaged by heat. Lighting fixtures must meet UL standards. 46CFR183.10-20(l)
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 25 May 2017
Resolved 12 May 2017
Resolution: lighting fixture cover replaced with new and shielded from exhaust piping.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 11 May 2017 Resolved
Broken outlet box exposed wiring in the accomodation space. Outlet boxes must be of watertight construction. 46CFR183.10-20(k)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 June 2017
Resolved 12 May 2017
Resolution: outlet box replaced.
Electrical › Electrical Distribution System (service) › Wiring
Issued 11 May 2017 Resolved
Unsupported electrical wiring bundled in foward, starboard accommodation space. Electrical installations shall be to the satisfaction of the OCMI. 46CFR183.01-15(a)
Action required: 705 - Other - as specified
Due 18 May 2017
Resolved 12 May 2017
Resolution: Properly supported bundled wiring.
Construction/Loadline › Hull › Hull Plating
Issued 3 February 2017 Resolved
Multiple holes found along chine of vessel on Port/Stbd sides in vicinity of engine room. Additional holes found in bottom plating around port/stbd shaft logs. Request removal of paint to bare metal on sections identified in need of further nondestructive testing (UT) on sides and bottom plating of hull (crop & renew at later date).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 March 2017
Resolved 19 April 2017
Resolution: Due to extensive repairs conducted vessel was in an extended drydock. All holes removed and replaced with a large insert. Tested and inspected insert passed visual testing and hydro of weld. //s// [name withheld], GS09, USCG Marine Inspector
Construction/Loadline › Hull › Bottom Plating
Issued 3 February 2017 Resolved
Pitting in excess of 25% found spread out around STBD shaft log.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 March 2017
Resolved 19 April 2017
Resolution: Due to extensive repairs conducted vessel was in an extended drydock. All pitting removed and replaced with a large insert. Tested and inspected insert passed visual testing and hydro of weld. //s// [name withheld], GS09, USCG Marine Inspector
Engineering › Fuel Oil Service System › Valve, Control
Issued 3 February 2017 Resolved
No piping / caps leading aft from port/stbd fuel shutoff valves for engines. Shutoff valves, installed shall be fitting in supply lines. Repair or replace fuel shutoff valves.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 March 2017
Resolved 19 April 2017
Resolution: Due to extensive repairs conducted vessel was in an extended drydock. Removed old fuel piping. Repaired, replaced,and capped fuel lines. //s// [name withheld], GS09, USCG Marine Inspector
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 3 February 2017 Resolved
MSD tank deteriorated and contains multiple holes. Due to deterioration of tank, provide proposal to replace MSD for OCMI review.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 March 2017
Resolved 27 March 2017
Resolution: Vessel rep provided repair proposals. New MSD tank replaced in kind.
Construction/Loadline › Penetrations › Gasket
Issued 3 February 2017 Resolved
Sealant (gasket) used to secure stbd side transducer leaking water due to deterioration. Deterioration to structural members that affects seaworithenss of vessel is discovered. Make means availabe to further inspect stbd side transducer.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 March 2017
Resolved 19 April 2017
Resolution: Vessel had stbd transducer removed and installed all new gasket material and sealant. inspected transducer install passed visual inspection. //s// [name withheld], GS09, USCG Marine Inspector
Engineering › Fuel Oil Service System › Filter
Issued 3 February 2017 Resolved
4 fuel filters leaking fuel from drip pans. A suitable marine type strainer shall be fitted in the fuel supply line in the engine compartment. Repair or replace fuel filters.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 March 2017
Resolved 19 April 2017
Resolution: Replaced all filters with new filters as well as installed a new Raycor system. Passed visual inspection. //s// [name withheld], GS09, USCG Marine Inspector
Stability › Watertight Integrity › General
Issued 3 February 2017 Resolved
Insufficient seal on 2 hydraullic piping lines penetrating stbd side collision bulkhead. Each collision bulkhead must have means to make them watertight. Ensure collision bulkhead is watertight around all penetrations.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 March 2017
Resolved 19 April 2017
Resolution: Capped and resealed all penetrations on the stbd side of collision bulkhead. inspected sat. //s// [name withheld], GS09, USCG Marine Inspector
Engineering › Steering Gear System › Fastener
Issued 3 February 2017 Resolved
Cracked weld between frame and support for port steering gear stop. Deterioration to hull plating affecting seaworthiness of vessel. Gouge and well to effect permanent repairs.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 March 2017
Resolved 19 April 2017
Resolution: Escavated and re-welded the cracked weld on the port steering gear stop. repair complete passed visual inspection. //s// [name withheld], GS09, USCG Marine Inspector
Construction/Loadline › Hull › Weld
Issued 3 February 2017 Resolved
Washed out welds below waterline throughout vessel. Deterioration to hull plating welds affecting the seaworthiness of vessel. Have marine chemist gas free fuel tank and vessel surrounding areas prior to conducting any hot work. Gouge and weld to effect repairs.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 March 2017
Resolved 6 March 2017
Resolution: Vessel rep provided gas free certificate and maintained spaces for hot work. Washed out welds back gouged and welded for permanent repairs.
Stability › Watertight Integrity › General
Issued 3 February 2017 Resolved
Dead-end non-metallic hoses extending aft on port side of collision bulkhead. Each penetration must be accomplished using an acceptable metallic through deck or through bulkhead fitting that is welded or otherwise attached to the bulkhead or deck by an acceptable method. Remove dead-end hoses and ensure watertight integrity of watertight subdivision.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 March 2017
Resolved 27 March 2017
Resolution: Vessel rep removed dead end hoses and provided suitable means to ensure watertight subdivision.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 3 February 2017 Resolved
Oil, debris, and trash adrift in engine room deck. Bilges and other spaces not to have accumulation of oil or other matter which might create a fire hazard. Clean and remove said debris to allow further inspection and prevention of hazards.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 March 2017
Resolved 8 February 2017
Resolution: Vessel rep steam cleaned and removed debris from engine room.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 3 February 2017 Resolved
MSD vent pipe has deep circular pitting at flexible connection. Due to location, provide proposal to repair vent pipe for OCMI review.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 March 2017
Resolved 27 March 2017
Resolution: Vessel rep provided repair proposals for MSD vent piping and replaced piping in accordance with proposal and regulations with PVC piping.
Engineering › Fuel Oil Service System › Piping
Issued 3 February 2017 Resolved
Flexible sections that are nonconductors of electricity are not joined by a conductor for protection on fuel fill and fuel vent pipes. Install conductors to protect against static charge.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 March 2017
Resolved 27 March 2017
Resolution: Vessel rep installed bonding cables from metallic piping to vessel framing for both port/stbd fill pipes.
Engineering › Fuel Oil Service System › Piping
Issued 3 February 2017 Resolved
Stbd fuel fill pipe has temporary repair (soft-patch); remove for further inspection.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 March 2017
Resolved 27 March 2017
Resolution: Vessel rep removed soft patch for inspection. After inspection, vessel rep replaced fill piping in kind.
Accommodation/Occupational Safety › Sleeping Accommodations › Berth
Issued 3 February 2017 Resolved
Lower sections of false bulkheads / paneling throughout passenger accomodation space are deteriorated; there is a presence of a white crystallized substance on deteriorated sections. Provide repair proposal to replace sections for OCMI review.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 March 2017
Resolved 19 April 2017
Resolution: Installed new false bulkheads and cleaned all spaces.
Accommodation/Occupational Safety › Sleeping Accommodations › Berth
Issued 3 February 2017 Resolved
Top section of MSD tank has a bunk located directly above and is currently being used as a bunk for overnight accommodation. Bunk should be removed or relocated. Provide proposal to relocate or remove berth for OCMI review.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 March 2017
Resolved 10 February 2017
Resolution: Vessel rep provided proposal to remove (excess) berth permanently above MSD tank.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 3 February 2017 Resolved
MSD tank is located in passenger accommodation space. Passenger accommodation space must not contain pipelines. Provide proposal to isolate MSD tank and piping from passenger accommodation space for OCMI review.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 March 2017
Resolved 19 April 2017
Resolution: Due to extensive repairs conducted vessel was in an extended drydock. Vessel removed and disposed of old type 3 msd tank. Vessel submitted plans for new type 3 msd tank. Vessel installed tank and was hydro tested for leaks. Passed inspection.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 3 February 2017 Resolved
Worn-out sections of insulation on machinery (main propulsion and generators) exhaust in engine room will require replacement. Due to lead time of acquiring lagging, due date will be extended to accommodate replacement of lagging.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 May 2017
Resolved 11 May 2017
Resolution: Worn-out sections of insulation on MDE's and generator exhaust piping was replaced.
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 11 May 2016 Resolved
Exhaust stacks in engine room covered with oil. Clean and remove all traces of oil and residue.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 May 2016
Resolution: Exhaust stacks cleaned and free of oil and residue.
Engineering › Diesel Engine (propulsion-reduction gear) › Turbocharger
Issued 11 May 2016 Resolved
Air intakes on engines (turbo) are soaked with oil. Replace filters.
Due 18 May 2016
Resolved 13 May 2016
Resolution: Air filters have been replaced with new units.
Engineering › Steering Gear System › Rudder
Issued 11 May 2016 Resolved
Port side rudder stop has crack in weld. Repair weld.
Action required: 705 - Other - as specified
Due 25 May 2016
Resolved 27 May 2016
Resolution: Cracked weld repaired.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 11 May 2016 Resolved
All crew members must be enrolled in company drug and alcohol program. One employee (operating as a deck hand) is not.
Action required: 705 - Other - as specified
Due 27 May 2016
Resolved 27 May 2016
Resolution: Provided documentation that all crewmembers enrolled into DAPI program.
Engineering › Pressure Vessel › Relief Valve
Issued 11 May 2016 Resolved
Pressure relief valves on air receivers need to be replaced. Valves don't have servicing tag or proof of servicing.
Action required: 705 - Other - as specified
Due 20 May 2016
Resolved 19 May 2016
Resolution: Pressure relief valves on both air recievers were replaced with new units.
Electrical › Lighting (emergency) › Lighting Branch Circuit
Issued 11 May 2016 Resolved
Emergency lighting system inoperable.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 May 2016
Resolution: Proven proper operation of emergency lighting system.

Casualty record · 1

9 June 2009Routine · role: Acknowledged Pollution Source · activity 3500224
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.