Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Registered dimensions (L × B × D)100.4 ft × 27.5 ft × 7.3 ft
Registered tonnagegross 97 / net 66
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTHAMES S/Y & REPAIR CO · NEW LONDON CT, UNITED STATES · built 1969
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW LONDON, CT
Endorsements, as the file codes themcw_un
DocumentationValid · issued 14 July 2026 · expires 31 July 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it97 - Regulatory (Subpart C or D), Gross Ton 66 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel
Behind this panel: 22 inspections, each with its date, unit and type; 17 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1972 to
2026, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 19 November 2024Resolved
An exposed hazard must be protected by a cover, guard, or rail. Permanently secure the protective cover on the potable water pump.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 December 2024
Resolved 20 December 2024
Resolution: Cover secured.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 19 November 2024Resolved
Auxiliary boilers and heating boilers and their associated piping and fittings must meet the applicable requirements of subchapter F (Marine Engineering). Renew the wasted boiler exhaust cover.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 December 2024
Resolved 24 January 2025
Resolution: Cover plate renewed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 November 2024Resolved
Each life jacket must be marked in clearly legible block capital letters with the vessel's name. Ten adult life jackets were missing the vessel's name.
Action required: 10 - Deficiency Rectified
Due 19 November 2024
Resolved 19 November 2024
Resolution: Lifejackets were stenciled.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 9 November 2023Resolved
At each initial and subsequent inspection for certification of a vessel,the owner or managing operator shall have the vessel ready for inspection and operation of all weathertight closures above the weather deck. The port holes located on the vehicle deck were not able to be closed or tightened.
Action required: 10 - Deficiency Rectified
Resolved 13 November 2023
Resolution: Vessel cleaned the closures devices free of paint
At each initial and subsequent inspection for certification of a vessel,the owner or managing operator shall have the vessel ready for inspection and operation of all weathertight closures above the weather deck. Light was visible around the seal of the 01 deck stbd weathertight door after closure.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 November 2023Resolved
Electrical equipment on a vessel must be installed and maintained to protect crew from electrical hazards and minimize accidental personnel contact with energized parts. The electric panel located in the engine room was held open and the latch was broken.
Action required: 10 - Deficiency Rectified
Resolved 13 November 2023
Resolution: the latch was replaced.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 8 December 2022Resolved
The master shall conduct sufficient drills and give sufficient instructions to make sure that all crew members are familiar with their duties. Crew was unable to properly recover MOB using Jason's Cradle.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 January 2023
Resolved 13 December 2022
Resolution: Jason's cradle properly secured to vessel. All sat.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 8 December 2022Resolved
All cables and wire must be installed with metal supports spaced not more than 24 inches apart. Bilge alarm cable in void #5 has broken supports.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 January 2023
Resolved 13 December 2022
Resolution: Cable properly secured. All sat.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 February 2022Resolved
Portable fire extinguishers must be located so that they are clearly visible and readily accessible. The installation must be to the satisfaction of the cognizant OCMI. The bracket for the #3 portable fire extinguisher on the car deck is broken.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 March 2022
Resolved 22 February 2022
Resolution: Reattached bracket for fire extinguisher.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 15 February 2022Resolved
All escape hatches used as means of escape must be marked on both sides in letters at least 2 inches high: EMERGENCY EXIT, KEEP CLEAR. The emergency escape hatch from the engine room to the car deck is not marked on the outside.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 March 2022
Resolved 22 February 2022
Resolution: Escape hatch has been marked.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 25 October 2019Resolved
Complete but simple instructions for the operation of a fixed gas fire extinguishing system must be located in a conspicuous place at or near each pull box and stop valve control and in the space where the extinguishing agent cylinders are stored. Instructions missing by pull box/stop valve.
Action required: 10 - Deficiency Rectified
Due 25 October 2019
Resolved 25 October 2019
Resolution: Instructions were posted.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 September 2018Resolved
Boiler did not have a low water cut out safety control installed as required. Install and test low water cut out safety control to the satisfaction of the attending USCG Marine Inspector prior to placing into service with passengers.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 25 September 2018
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 September 2018Resolved
17 Life jackets retro reflective tape unservicable, replace retro reflective tape as discussed.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 October 2018
Resolved 25 September 2018
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 20 September 2018Resolved
New installation of portable 15Lb CO2 fire extinguisher in engine room does not meet required rating of 40-B:C. Replace with portable extinguisher with a minium rating of 40-B:C.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Resolved 5 October 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 September 2018Resolved
Test installed safeties, relief valve, hydro test, fire and water side inspections prior to placing boiler into service.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 25 September 2018
Lifesaving › Lifefloat › Not on Board
Issued 12 October 2017Resolved
Total persons reduced to 164 in cold water due to the removal of two 22 man lifefloats.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 November 2017
Resolved 25 May 2018
Construction/Loadline › Hull › Side Shell
Issued 5 August 2017Resolved
Vessel allision, conduct damage survey prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 August 2017
Resolved 6 August 2017
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.