Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 9 April 2026
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDL3224
466001
Flag
UNITED STATES
Maury page id
psix-466001

Documentation record

Registered dimensions (L × B × D)41.0 ft × 14.0 ft × 7.0 ft
Registered tonnagegross 26 / net 21
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMORGAN BOATS INC · NAPLES, FL, UNITED STATES · built 1997
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portORANGE BEACH, AL
Endorsements, as the file codes themcw_un, fi
DocumentationValid · issued 24 October 2025 · expires 31 October 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it26 - Simplified, Gross Ton
21 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 19 inspections, each with its date, unit and type; 19 deficiencies with the resolution recorded against each, 1 without one; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 19

9 April 2026 Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8345268
3 February 2026 Internal Structural Exam · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8305414
15 January 2025 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8064114
23 April 2024 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7896176
21 February 2024 Hull Examination · Drydock Exam · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7868098
25 April 2023 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7674967
7 April 2022 Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7426584
25 February 2022 Administrative Inspection · Drydock Exam · Deficiency Check · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7404760
23 February 2021 In-Service Inspection · Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7145167
14 October 2020 Damage Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7077224
28 February 2020 Administrative Inspection · Drydock Exam · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6917745
6 December 2019 Administrative Inspection · COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6868999
21 October 2019 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6838745
5 June 2019 Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6703601
4 June 2018 Administrative Inspection · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6431396
8 May 2018 Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6407848
25 May 2017 Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6152654
18 May 2016 DAPI Audit · COI Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 5857583
10 May 2016 Hull Examination · Deficiency Check · Examination of Repairs
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 5857589

Deficiency record · 19

05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 27 April 2026 No resolution recorded
VESSELS OPERATED BEYOND 20 NAUTICAL MILES BUT NOT MORE THAN 100 MILES MUST BE EQUIPPED WITH A MF-DSC FREQUENCY TRANSMITTER CAPABLE OF TRANSMITTING J3E EMISSION AND RECEPTION WITHIN THE BAND 1710 TO 2850 KHZ. VESSEL'S SINGLE SIDE BAND RADIO (SSB) FCC EXEMPTION LETTER IS EXPIRED AND DOESN'T HAVE AN APPROVED MF-DSC RADIO ON BOARD MEETING THE SINGLE SIDE BAND REQUIREMENTS. VESSEL IS RESTRICTED TO 20 MILES FROM SHORE 47 CFR 80.905(2)
Condition: Invalid
Action required: 705 - Other - as specified
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 23 April 2024 Resolved
Provision must be made for closing all supply duct cowls for a space protected by a fixed gas extinguishing system. Vessel's ventilation supply covers could not be sealed or secured in any way. Install the covers in such a way to seal and secure the ventilation openings.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 May 2024
Resolved 2 May 2024
Resolution: Vessel representative provided a photograph of latches used to secure the dampeners.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 26 April 2023 Resolved
FLEXIBLE HOSE DESIGNED FOR USE WITH HOSE CLAMPS AT BOTH ENDS OF THE HOSE. VESSEL HAD INSTALLED FLEXIBLE HOSES ATTACHED TO FUEL RACOR FILTER WITHOUT REQUIRED NUMBER OF HOSE CLAMPS.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 May 2023
Resolved 22 May 2023
Resolution: Vessel owner sent in photographic evidence of the new fuel hoses with double hose clamps.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 25 February 2022 Resolved
Steering gear hatch gasket was wasted and not serviceable.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 March 2022
Resolved 12 March 2022
Resolution: Photos provided of new gasket installed
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 25 February 2022 Resolved
Screws on handrails loose.
Due 11 March 2022
Resolved 12 March 2022
Resolution: Screws tightened.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 25 February 2022 Resolved
Pipe penetration not watertight.
Due 11 March 2022
Resolved 12 March 2022
Resolution: Pipe penetration made watertight.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 1 March 2021 Resolved
Vessels must have the ability to conduct alcohol testing within two hours of a serious marine incident. Alcohol testing strips were expired. Provide proof of valid testing strips.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 March 2021
Resolved 5 March 2021
Resolution: Vessel owner provided verification of alcohol testing strips.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 1 March 2021 Resolved
Vessel lifefloats must have Type II retroflective tape. Incorrect tape was on the lifefloat. Provide evidence of correct tape.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 March 2021
Resolved 11 March 2021
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 14 October 2020 Resolved
No repairs or alterations affecting the safety of the vessel or its machinery shall be made unless applicable requirements in this chapter are met. The procedures to be followed in notifying the Coast Guard about vessel repairs vary according to the type of vessel and service in which engaged. Vessel owner/operator notified CG that the vessel suffered damage due to Hurricane Sally in accordance with applicable regulatory cite. Vessel must make permanent repair/alteration to the satisfaction of the OCMI in accordance with 46 CFR 176.700(a).
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 March 2021
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 January 2020 Resolved
Multiple wires under primary operating station found cut or not connected. Connect wires to proper location or removed unused wires.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 February 2020
Resolved 9 April 2020
Resolution: removed wires
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 January 2020 Resolved
Broken wire at terminal lug on starboard engine starter. Install new lug on wire and reconnect.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 February 2020
Resolved 9 April 2020
Resolution: Removed wire
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 30 January 2020 Resolved
Port and starboard aft fuel tank supply remote valve shutoff cables broken or severely corroded at valve handle. Replace cable or apply new cable crimps.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 April 2020
Resolution: Replaced vavle
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 30 January 2020 Resolved
Port and starboard engines both missing required machinary covers. Install machinary covers.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 April 2020
Resolution: Installed machinery guard covers for both main engines.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 30 January 2020 Resolved
Lazarette high water audible alarm not functioning properly. Replace audible alarm.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 April 2020
Resolution: Repaired alarm
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 5 June 2019 Resolved
Fuel shutoff on center tank is broken, repair prior to using auxilairy tank. (46CFR182.458(b)(4)
Action required: 705 - Other - as specified
Resolved 10 June 2019
Resolution: Installed new shutoff valve.
Construction/Loadline › Hull › Bottom Plating
Issued 10 May 2016 Resolved
Make permanent repairs to all areas identified on the hull during inspection, IAW 46 CFR 176.610.
Action required: 705 - Other - as specified
Resolved 13 May 2016
Resolution: All spots were sanded/ground down to solid laminate and repaired new glass and epoxy filler.
Engineering › Fuel Oil Service System › Piping
Issued 10 May 2016 Resolved
Troubleshoot to find location of fuel leak in Lazarette and repair, IAW 46 CFR 182.455(b)(3).
Action required: 705 - Other - as specified
Resolved 13 May 2016
Resolution: Owner installed new section of fuel piping.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 10 May 2016 Resolved
Replace outlet/wall socket in forward accomodation, IAW 46 CFR 183.220.
Action required: 705 - Other - as specified
Resolved 13 May 2016
Resolution: New outlet installed.
Accommodation/Occupational Safety › Refrigeration (air conditioning) › General
Issued 10 May 2016 Resolved
Replace identified 3/4" A/C cooling pump seawater valve, IAW 46 CFR 176.610.
Action required: 705 - Other - as specified
Resolved 13 May 2016
Resolution: New valve installed.

Ownership record