MAURY USCG vessel records
← All vessels

HOPPER V

Built
1997
Last inspected
14 May 2024
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 14 May 2024
Operational controls None recorded without a removal date
Years with a record 9 calendar years (2016–2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

EXEMPT
466035
Flag
UNITED STATES
Maury page id
psix-466035

Documentation record

Registered dimensions (L × B × D)29.0 ft × 12.0 ft × 5.4 ft
Registered tonnagegross 12 / net 10
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderISLAND HOPPER BOATS INT'L · FT PIERCE, FL, UNITED STATES · built 1997
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portSOUTH LAKE TAHOE, CA
Endorsements, as the file codes themcw_un, rec
DocumentationValid · issued 2 May 2026 · expires 30 June 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it12 - Simplified, Gross Ton
10 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 10 inspections, each with its date, unit and type; 9 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; 1 other recorded name; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 10

14 May 2024 Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7909640
8 September 2023 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7794108
16 May 2023 Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7684925
3 May 2022 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7437715
27 April 2021 COI Inspection · Drydock Exam · Internal Structural Exam · Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7182383
11 May 2020 Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6949172
10 May 2019 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6681307
11 June 2018 Administrative Inspection · Internal Structural Exam · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6441542
9 May 2017 Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6147559
3 April 2016 Internal Structural Exam · Drydock Exam · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5863071

Deficiency record · 9

07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 14 May 2024 Resolved
Provision shall be made by means of plugs, covers, etc. to prevent the admission of air into the space protected. No closure devices for vents onboard. 46 CFR 182.465
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2024
Resolved 14 August 2024
Resolution: Verified closure device
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 14 May 2024 Resolved
At each subsequent inspection for certification of a vessel, the owner or operator shall be prepared to conduct tests and have the vessel ready for inspection and operation of all weathertight closures above weather deck and provisions for drainage of sea water from exposed decks. Forward engine room and lazarette hatches did not prevent water intrusion. Repair to satisfaction of attending MI. 46 CFR 176.802
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2024
Resolved 25 July 2024
Resolution: Gasket replaced on hatches
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 14 May 2024 Resolved
At each subsequent inspection for certification of a vessel, the owner or operator shall have the vessel ready for inspections of machinery, fuel, and piping systems. Identified hole in wet exhuast lagging. 46 CFR 176.804
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2024
Resolved 25 July 2024
Resolution: Hole in lagging repaired
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 14 May 2024 Resolved
The Coast Guard will issue a medical certificate to a mariner meeting the medical and physical standards for merchant mariners. The captain did not have medical certificate onboard and available. 46 CFR 10.301
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2024
Resolved 17 October 2024
Resolution: Verified valid medical certificate
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 May 2024 Resolved
A vessel must be provided with bilge pumps in accordance with table 182.520(a). Vessel's fixed bilge pump for forward compartment is inoperable. 46 CFR 182.520(a)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 June 2024
Resolved 22 August 2024
Resolution: Verified operation of bilge pump
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 16 May 2023 Resolved
Boundaries that separate machinery spaces from accommodation spaces must be lined with noncombustible panels or insulation of an approved type. Insulation on engine room hatch tearing on upper left corner. Reattach insulation pieces. 46 CFR 177.410
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2023
Resolved 9 August 2023
Resolution: Vessel operator reached out to MI on 09AUG2023. Verified deficiency rectification.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 10 May 2019 Resolved
Electrical equipment must be drip proof in a location normally exposed to splashing, water wash down, or other wet conditions in a machinery space (fuse block under main deck battery access hatch).
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 July 2019
Resolved 15 May 2019
Resolution: [name withheld] verified fuse block water and corrosion was corrected.
Lifesaving › Lifefloat › Float Free
Issued 9 May 2017 Resolved
Line connecting the life float to the weak link was obstructed by a screw and nut arrangement which in the event the line spooled out, the screw/nut would prevent the life float from releasing.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 May 2017
Resolved 9 May 2017
Resolution: Rep removed screw/nut.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 9 May 2017 Resolved
COD expired.
Condition: Improper/Lack of Maintenance
Due 9 May 2017
Resolved 15 May 2017
Resolution: Verified new COD issued.

Recorded names · 1

SILENT WORLD (2006–2010). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.