MAURY USCG vessel records Sign in
← All vessels

SEA STAR

SEA STAR is a 1970 passenger vessel (inspected). The Coast Guard has recorded 55 inspections since 1985, most recently in May 2026, along with 96 deficiencies — 8 with no resolution recorded — and 1 casualty investigation in 2008.

Records from 1985 to 2026. Most recent: inspection, 29 May 2026.

Built
1970
Last inspected
29 May 2026
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDB7848
Flag
UNITED STATES
366948690 (licence lapsed)
Maury page id
psix-46604

Inspections, by type

…with no type recorded3
Years with a record 31 calendar years (1985–2026)
The 55 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)45.2 ft × 14.3 ft × 5.9 ft
Registered tonnagegross 22 / net 18
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
Builderbuilder not recorded · CRANBERRY ISLE, ME, UNITED STATES · built 1970
Hull materialWood
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portBOSTON, MA
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it22 - Regulatory (Subpart C or D), Gross Ton
18 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDB7848MMSI 366948690 · expired · compulsorily equipped · granted 13 March 2014, cancelled 20 July 2024
WBR3962MMSI not assigned · cancelled · voluntarily equipped · granted 9 December 1997, cancelled 17 May 2004
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 55

29 May 2026 Plan Review "T" Boat
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8383640
1 March 2021 Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 7150846
30 April 2019 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 6673638
29 May 2018 DAPI Audit · Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 6427815
10 July 2017 DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 6204546
18 April 2017 Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 6127069
2 June 2016 Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 5894778
4 June 2014 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 4880004
21 September 2008 Type not recorded
No type recorded · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 3332250
12 June 2008 COI Inspection
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 3234060
8 May 2007 Annual Inspection
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 2924925
23 March 2007 Hull Examination
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 2892870
8 May 2006 Annual Inspection
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 2643975
2 June 2005 Annual Inspection
Physical examination · MSFO Portsmouth · USCG Northeast District (CGD-NE) · Activity 2386402
29 March 2005 Hull Examination
Physical examination · MSFO Portsmouth · USCG Northeast District (CGD-NE) · Activity 2324582
2 June 2004 Annual Inspection
Physical examination · MSFO Portsmouth · USCG Northeast District (CGD-NE) · Activity 2087636
15 May 2003 Deficiency Check · Re-Inspection
Physical examination · MSFO Portsmouth · USCG Northeast District (CGD-NE) · Activity 1799175
16 April 2003 Internal Structural Exam · Hull Examination
Physical examination · MSFO Portsmouth · USCG Northeast District (CGD-NE) · Activity 1775368
29 April 2002 Deficiency Check · Re-Inspection
Physical examination · MSFO Portsmouth · USCG Northeast District (CGD-NE) · Activity 1610857
18 March 2002 Administrative Inspection
Administrative · MSFO Portsmouth · USCG Northeast District (CGD-NE) · Activity 1495503
3 May 2001 Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1462220
21 March 2001 Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1457905
4 May 2000 COI Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1386779
27 April 1999 Re-Inspection · Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1429126
20 April 1999 Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1406478
18 May 1998 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1125768
30 April 1997 MARPOL Annex V Examination · COI Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1092776
30 April 1997 Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1095054
2 October 1996 Type not recorded
No type recorded · USCG Northeast District (dp) · USCG Northeast District (CGD-NE) · Activity 659525
16 May 1996 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1082975
1 May 1996 Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1078127
2 May 1995 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 868304
23 June 1994 Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1135275
4 May 1994 Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 861151
3 May 1994 COI Inspection · MARPOL Annex V Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 860206
12 April 1994 Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1168049
14 June 1993 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1149249
10 May 1993 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 843397
30 April 1993 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 834696
28 October 1992 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 943900
30 April 1992 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1263374
3 May 1991 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1234379
5 April 1991 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1237199
28 March 1991 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 909735
11 May 1990 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1230733
17 October 1989 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1352818
23 June 1989 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1208683
15 May 1989 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1045008
27 April 1988 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 887523
1 April 1988 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 887521
4 September 1987 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1005234
30 April 1987 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1018313
25 April 1986 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1307368
13 March 1986 Credit Drydock
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1300252
2 May 1985 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 983949

Deficiency record · 96

03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 14 April 2021 No resolution recorded
A submersible electric bilge pump may be used as a power bilge pump required by Table 182.520(a) only on a vessel of not more than 19.8 meters (65 feet) in length carrying not more than 49 passengers, other than a ferry, provided that: A positive shutoff valve is installed at the hull penetration. On SEA STAR, multiple pump discharge hull penetrations are not fitted with positive shutoff valves. Resolve to the satisfaction of MI/OCMI in operating zone.
Action required: 701 - Prior to carriage of passengers/cargo
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 12 July 2018 Resolved
Label emergency escape hatch
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 July 2018
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 12 July 2018 Resolved
Provide current publications
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 July 2018
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 12 July 2018 No resolution recorded
Provide licensed master
Action required: 701 - Prior to carriage of passengers/cargo
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 12 July 2018 No resolution recorded
Provide servicing certificate
Action required: 701 - Prior to carriage of passengers/cargo
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 12 July 2018 Resolved
Provide light for engine room high bilge alarm
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 July 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 12 July 2018 No resolution recorded
Prove proper operation of bilge pump
Action required: 701 - Prior to carriage of passengers/cargo
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 12 July 2018 No resolution recorded
Prove proper operation of navigation electronics
Action required: 701 - Prior to carriage of passengers/cargo
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 12 July 2018 No resolution recorded
Complete MOB and fire drills
Action required: 701 - Prior to carriage of passengers/cargo
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 July 2018 No resolution recorded
Prove proper operation
Action required: 701 - Prior to carriage of passengers/cargo
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 12 July 2018 No resolution recorded
Provide current servicing certificate
Action required: 701 - Prior to carriage of passengers/cargo
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 12 July 2017 Resolved
Provide current test kits
Due 28 July 2017
Resolved 2 August 2017
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 12 July 2017 Resolved
Broken
Due 21 July 2017
Resolved 20 July 2017
Fire Fighting › Fire Bucket › Quantity
Issued 12 July 2017 Resolved
Provide 1 additional
Due 28 July 2017
Resolved 20 July 2017
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 12 July 2017 Resolved
Provide for deck hand
Due 28 July 2017
Resolved 2 August 2017
Communications › Radio Communications › VHF Radiotelephone
Issued 23 June 2016 Resolved
VHF/DSC not connected to GPS
Due 23 July 2016
Resolved 29 June 2016
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 23 June 2016 Resolved
Float light batteries expired
Due 1 July 2016
Resolved 24 June 2016
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 23 June 2016 Resolved
Provide ammonia inhalants
Due 8 July 2016
Resolved 29 June 2016
Personnel › Certificates/Documents/Licenses › License, Radio Officer
Issued 23 June 2016 Resolved
Provide Marine Radio Operators Permit
Due 1 July 2016
Resolved 30 June 2016
Fire Fighting › Fire Bucket › Availability
Issued 23 June 2016 Resolved
Provide proper size and number of fire buckets
Due 1 July 2016
Resolved 24 June 2016
Navigation › Piloting/Steering › Marine Charts
Issued 23 June 2016 Resolved
Provide current charts and LNM for area.
Due 1 July 2016
Resolved 28 June 2016
Communications › Radio Communications › EPIRB
Issued 23 June 2016 Resolved
Provide vessels EPIRB in float free position
Due 1 July 2016
Resolved 24 June 2016
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 23 June 2016 Resolved
Exhaust cooling pump cover leaks excessively
Due 1 July 2016
Resolved 27 June 2016
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 4 June 2014 Resolved
FCC Safety Radio Certificate is expired. Renew as original with FCC.
Action required: 705 - Other - as specified
Due 13 June 2014
Resolved 13 June 2014
Resolution: Corrected to the satisfaction of attending USCG Marine Inspector.
Documentation › Certificates/Documents › Stability Letter
Issued 4 June 2014 Resolved
Vessel Stability Letter is to be posted behind glass for passengers to view.
Action required: 705 - Other - as specified
Due 13 June 2014
Resolved 13 June 2014
Resolution: Corrected to the satisfaction of attending USCG Marine Inspector.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 4 June 2014 Resolved
Vessel's drug and alcohol program records were not available for inspection.
Action required: 705 - Other - as specified
Due 13 June 2014
Resolved 13 June 2014
Resolution: Corrected to the satisfaction of attending USCG Marine Inspector.
Personnel › Training › First Aid/CPR
Issued 4 June 2014 Resolved
Provide proof of First Aid/CPR training for 50% of all crew members.
Action required: 705 - Other - as specified
Due 13 June 2014
Resolved 13 June 2014
Resolution: Corrected to the satisfaction of attending USCG Marine Inspector.
Navigation › Piloting/Steering › US Coast Pilot
Issued 4 June 2014 Resolved
Provide current and up to date U.S. Coast Pilot and U.S. Coast Guard Light List.
Action required: 705 - Other - as specified
Due 13 June 2014
Resolved 13 June 2014
Resolution: Corrected to the satisfaction of attending USCG Marine Inspector.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 4 June 2014 Resolved
Stern light is not working. Repair as original prior to carrying passengers (PTCP).
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 June 2014
Resolved 13 June 2014
Resolution: Corrected to the satisfaction of attending USCG Marine Inspector.
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 4 June 2014 Resolved
Hydrostatic release for inflatable liferaft is expired. Repalce as original prior to carrying passengers (PTCP).
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 June 2014
Resolved 13 June 2014
Resolution: Corrected to the satisfaction of attending USCG Marine Inspector.
Lifesaving › Lifefloat › Serviceable
Issued 4 June 2014 Resolved
Holes in lifefloat to be repaired with approved Jim-Buoy repair kit.
Action required: 705 - Other - as specified
Due 4 July 2014
Resolved 13 June 2014
Resolution: Corrected to the satisfaction of attending USCG Marine Inspector.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 4 June 2014 Resolved
Bilge alarms in forward and aft compartments are not functioning correctly. Repair as original prior to carrying passengers (PTCP). Short term exception until 6/13/14 allowed if vessel maintains one hour soundings of both spaces with written records logged in the vessel's log book for all times that passengers are on board the vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 June 2014
Resolved 13 June 2014
Resolution: Corrected to the satisfaction of attending USCG Marine Inspector.
Construction/Loadline › Hull › Transverse Frame
Issued 4 June 2014 Resolved
Three frames in the aft starboard side of the engine compartment were observed cracked. Repair as original in accordance with wood NVIC 7-95.
Action required: 705 - Other - as specified
Due 30 November 2014
Resolved 20 April 2015
Resolution: Repaired to the satisfaction of attending USCG Marine Inspector.
Fire Fighting › Fire Bucket › Availability
Issued 8 May 2006 Resolved
PROVIDE THREE FIRE BUCKETS WITH LANYARDS.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 June 2006
Resolved 30 May 2006
Lifesaving › Lifebuoys › Approval
Issued 8 May 2006 Resolved
PROVIDE ONE LIFE BUOY WITH 60' LINE.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 June 2006
Resolved 30 May 2006
Personnel › Manning/Qualifications › First Aid Certified Personnel
Issued 8 May 2006 Resolved
PROVIDE FIRST AID TRAINING FOR AT LEAST 50% OF THE CREW.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 June 2006
Resolved 30 May 2006
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 2 June 2004 Resolved
Provide two flashlights.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 June 2004
Resolved 3 June 2004
Resolution: Provided.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 2 June 2004 Resolved
Provide two approved brackets.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 June 2004
Resolved 29 March 2005
Resolution: Owner had purchased two new BII Ext. with approved brackets.
Documentation › Certificates/Documents › FCC SSL
Issued 2 June 2004 Resolved
Provide current FCC Safety Certificate.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 June 2004
Resolved 3 June 2004
Lifesaving › Lifefloat › Serviceable
Issued 2 June 2004 Resolved
Repair or replace 12 man lifefloat.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 June 2004
Resolved 10 June 2004
Resolution: Provided new 12 man lifefloat.
Engineering › Bilge Water Management System › Not Operational
Issued 2 June 2004 Resolved
Repair aft bilge hi-level alarm.
Action required: 705 - Other - as specified
Due 3 June 2004
Resolved 3 June 2004
Resolution: Loose wire repaired.
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 15 May 2003 Resolved
SERVICE FIRE EXTINGUISHERS LEGACY COMPONENT DESC: Service
Condition: Unknown
Due 31 May 2003
Resolved 10 June 2003
Lifesaving › Hand Flares
Issued 15 May 2003 Resolved
PROVIDE REQUIRED DISTRESS SIGNALS LEGACY COMPONENT DESC: Quantity
Condition: Unknown
Due 31 May 2003
Resolved 10 June 2003
Lifesaving › Visual Distress Signals (General)
Issued 15 May 2003 Resolved
PROVIDE HYDROSTATIC RELEASE FOR EPRIB LEGACY COMPONENT DESC: Condition
Condition: Unknown
Due 31 May 2003
Resolved 10 June 2003
Electrical › Lighting (emergency)
Issued 15 May 2003 Resolved
PROVIDE TWO FLASHLIGHT
Condition: Unknown
Due 31 May 2003
Resolved 10 June 2003
Lifesaving › Rigid Liferafts
Issued 15 May 2003 Resolved
PROVIDE PROPER SIZED WEAK LINK LEGACY COMPONENT DESC: Hydrostatic Release Unit
Condition: Unknown
Due 31 May 2003
Resolved 15 May 2003
Lifesaving › Liferaft Equipment
Issued 15 May 2003 Resolved
CORRECTLY MOUNT HYDROSTATIC RELEASE TO RAFT
Condition: Unknown
Due 15 May 2003
Resolved 15 May 2003
Lifesaving › Buoyant Apparatus
Issued 15 May 2003 Resolved
RE-RETRO TAPE B/A LEGACY COMPONENT DESC: RETRO TAPE
Condition: Unknown
Due 31 May 2003
Resolved 10 June 2003
Documentation › Safety/Response Plans/Programs
Issued 15 May 2003 Resolved
POST EMERGENCY INSTRUCTION LEGACY COMPONENT DESC: EMERGENCY INSTRUCTION
Condition: Unknown
Due 31 May 2003
Resolved 10 June 2003
Electrical › Lighting (service)
Issued 15 May 2003 Resolved
PROVE PROPER OPERATION OF NAVIGATIONAL LIGHTS LEGACY COMPONENT DESC: NAV LIGHTS
Condition: Unknown
Due 31 May 2003
Resolved 10 June 2003
Engineering › Shafting/Propeller Arrangements › Coupling
Issued 29 April 2002 Resolved
MAKE PERMANENT REPAIRS TO STEERING/RUDDER FOUNDATION. LEGACY COMPONENT DESC: bolt
Condition: Unknown
Due 30 September 2002
Resolved 2 June 2004
Resolution: Owner has fabricated and installed new foundation.
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 29 April 2002 Resolved
SERVICE OR REPLACE TWO B-II PORTABLE FIRE EXTINGUISHERS LEGACY COMPONENT DESC: Service
Condition: Improper/Lack of Maintenance
Due 10 May 2002
Resolved 30 May 2002
Resolution: Extinguishers replaced.
Construction/Loadline › Penetrations
Issued 29 April 2002 Resolved
TIGHTEN STRUT BOLT LEGACY COMPONENT DESC: fastener
Due 10 May 2002
Resolved 30 May 2002
Resolution: Bolt tightened.
Electrical › Electrical Distribution System (emergency)
Issued 29 April 2002 Resolved
PROVE OPERATION OF TWO BILGE HIGH LEVEL ALARM LEGACY COMPONENT DESC: Switch
Due 10 May 2002
Resolved 30 May 2002
Resolution: Satisfactorily tested.
Construction/Loadline
Issued 21 March 2001 Resolved
IN THE PRESENCE OF A MARINE INSPECTOR, CONDUCT UNDERWAY EXAMINATION PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 21 March 2001
Resolved 21 March 2001
Navigation
Issued 4 May 2000 Resolved
PROVIDE NAVIGATION PUBS
Condition: Unknown
Due 4 May 2000
Resolved 4 May 2000
Navigation
Issued 4 May 2000 Resolved
TIGHTEN RUDDER MOUNTING
Condition: Unknown
Due 4 May 2000
Resolved 4 May 2000
Lifesaving
Issued 4 May 2000 Resolved
PROIVDE MISSING SMOKE VISUAL DISTRESS SIGNAL
Condition: Unknown
Due 4 May 2000
Resolved 4 May 2000
Lifesaving
Issued 4 May 2000 Resolved
PROVIDE WATER LIGHT TO THIRD B/A
Condition: Unknown
Due 4 May 2000
Resolved 4 May 2000
Lifesaving
Issued 27 April 1999 Resolved
Replace grab lines on two-eight man buoyant apparatus's as needed.
Condition: Unknown
Due 30 April 1999
Resolved 29 April 1999
Fire Fighting
Issued 27 April 1999 Resolved
Provide means to secure two engine room ventilation cowls located above wheel house.
Condition: Unknown
Due 30 April 1999
Resolved 29 April 1999
Construction/Loadline
Issued 27 April 1999 Resolved
Repair hand bilge pump hose connection.
Condition: Unknown
Due 27 April 1999
Resolved 27 April 1999
Lifesaving
Issued 27 April 1999 Resolved
Replace thirteen man buoyant apparatus. (grab line connection points_x001C_ deteriorated)
Condition: Unknown
Due 30 April 1999
Resolved 29 April 1999
Documentation
Issued 27 April 1999 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 27 April 1999
Resolved 27 April 1999
Documentation
Issued 27 April 1999 Resolved
Prepare and post Waste Management Plan.
Condition: Unknown
Due 30 April 1999
Resolved 29 April 1999
Documentation
Issued 27 April 1999 Resolved
Post both pages of COI.
Condition: Unknown
Due 30 April 1999
Resolved 29 April 1999
Documentation
Issued 27 April 1999 Resolved
Register New 406 MHZ EPIRB with NOAA.
Condition: Unknown
Due 31 May 1999
Resolved 29 April 1999
Documentation
Issued 27 April 1999 Resolved
Log garbage discharges.
Condition: Unknown
Due 30 April 1999
Resolved 29 April 1999
Construction/Loadline
Issued 30 April 1997 Resolved
Renew last frame, starboard side in engineroom.
Condition: Unknown
Due 1 May 1997
Resolved 1 May 1997
Construction/Loadline
Issued 30 April 1997 Resolved
Remove and renew rotted wood around lazerette hatch.
Condition: Unknown
Due 1 May 1997
Resolved 1 May 1997
Construction/Loadline
Issued 30 April 1997 Resolved
Get underway with marine inspector to check condition of hull._x001C_ _x001C_ To be completed prior to carrying passengers.
Condition: Unknown
Due 1 May 1997
Resolved 1 May 1997
Lifesaving
Issued 16 May 1996 Resolved
RE-STENCIL VESSEL NAME ON B/A
Condition: Unknown
Due 24 May 1996
Resolved 22 May 1996
Lifesaving
Issued 16 May 1996 Resolved
RENEW B/A WATERLIGHT TAG LINES
Condition: Unknown
Due 24 May 1996
Resolved 22 May 1996
Lifesaving
Issued 16 May 1996 Resolved
REPLACE WATERLIGHT BATTERIES
Condition: Unknown
Due 24 May 1996
Resolved 22 May 1996
Construction/Loadline
Issued 16 May 1996 Resolved
PROVIDE HATCH COVER TAG LINES
Condition: Unknown
Due 24 May 1996
Resolved 22 May 1996
Lifesaving
Issued 16 May 1996 Resolved
REPAINT FADED B/A
Condition: Unknown
Due 24 May 1996
Resolved 22 May 1996
Lifesaving
Issued 16 May 1996 Resolved
PROVIDE EMERGENCY BROADCAST PLACARD
Condition: Unknown
Due 24 May 1996
Resolved 22 May 1996
Construction/Loadline
Issued 1 May 1996 Resolved
RENEW SHORT SISTER FRAMES IN LAZERETTE COMPARTMENT IAW NVIC 7-95. FRAMES 1,2,4 FROM FORWARD BULKHEAD, PORT SIDE.
Condition: Unknown
Due 2 May 1996
Resolved 2 May 1996
Construction/Loadline
Issued 1 May 1996 Resolved
RENEW FRAME IN LAZERETTE COMPARTMENT #3 FROM FORWARD BULKHEAD, PORT SIDE
Condition: Unknown
Due 2 May 1996
Resolved 2 May 1996
Construction/Loadline
Issued 1 May 1996 Resolved
DOUBLE HOSE CLAMP ALL SEA WATER HOSES
Condition: Unknown
Due 2 May 1996
Resolved 2 May 1996
Construction/Loadline
Issued 1 May 1996 Resolved
GET VESSEL UNDERWAY WITH MARINE INSPECTOR TO CHECK CONDITION OF HULL._x001C_ TO BE DONE PRIOR TO CARRYING PASSENGERS
Condition: Unknown
Due 15 May 1996
Resolved 16 May 1996
Lifesaving
Issued 2 May 1995 Resolved
RENEW ONE WATERLIGHT MOUNT BRACKET
Condition: Unknown
Due 16 May 1995
Resolved 8 May 1995
Lifesaving
Issued 2 May 1995 Resolved
PROVIDE 24 INCH RING BUOY WITH LINE_x001C_ _x001C_ VESSEL NOT TO CARRY PASSENGERS UNTIL CORRECTED
Condition: Unknown
Due 16 May 1995
Resolved 8 May 1995
Electrical
Issued 2 May 1995 Resolved
COVER OPEN LIGHT SOCKETS IN CABIN
Condition: Unknown
Due 16 May 1995
Resolved 8 May 1995
Lifesaving
Issued 2 May 1995 Resolved
PROVIDE FIVE ADULT PFD's_x001C_ _x001C_ VESSEL RESTRICTED TO NOT MORE THAN 46 PERSONS ONBOARD UNTIL CORRECTED
Condition: Unknown
Due 16 May 1995
Resolved 8 May 1995
Documentation
Issued 2 May 1995 Resolved
PROVIDE VALID DOCUMENT
Condition: Unknown
Due 3 May 1995
Resolved 3 May 1995
Lifesaving
Issued 2 May 1995 Resolved
RENEW B/A PAINTER LINE
Condition: Unknown
Due 16 May 1995
Resolved 8 May 1995
Lifesaving
Issued 3 May 1994 Resolved
INSTALL REFLECTIVE TAPE ON ALL BAs_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 4 May 1994
Resolved 4 May 1994
Lifesaving
Issued 3 May 1994 Resolved
INSTALL WEAK LINK BETWEEN VESSEL AND PAINTER_x001C_ _x001C_ _x001C_ TO BE CORRECTED PRIOR TO THE CARRAGE OF PASSENGERS_x001C_
Condition: Unknown
Due 3 May 1994
Resolved 3 May 1994
Lifesaving
Issued 30 April 1993 Resolved
PROPERLY MOUNT RING BUOY IN AREA ACCESSIBLE.
Condition: Unknown
Due 30 May 1993
Resolved 17 May 1993
Lifesaving
Issued 30 April 1993 Resolved
PROVIDE AN ADDITIONAL 23 ADULT AND 1 CHILD LIFE PRESERVERS FOR INSPECTION BY AN ATTENDING COAST GUARD MARINE INSPECTOR, UNTIL SUCH TIME TOTAL PERSONSALLOWED IS REDUCED TO 28.
Condition: Unknown
Due 30 May 1993
Resolved 17 May 1993
Construction/Loadline
Issued 30 April 1993 Resolved
PROVIDE ACCESS FOR PUMP TO REMOVE WATER FROM FORE PEAK.
Condition: Unknown
Due 30 April 1993
Resolved 30 April 1993
Fire Fighting
Issued 30 April 1993 Resolved
SERVICE OR RENEW AND MAKE AVAILABLE FOR INSPECTION TWO TYPE OF PORTABLE FIRE EXTINGUISHERS PRIOR TO VESSEL OPERATION.
Condition: Unknown
Due 30 May 1993
Resolved 17 May 1993
Lifesaving
Issued 30 April 1993 Resolved
PROVIDE LIGHT FOR BUOYANT APPARATUS WHERE MISSING UNTIL SUCH TIME VESSEL OPERATION IS LIMITED TO DAYLIGHT OPERATION ONLY.
Condition: Unknown
Due 30 April 1993
Resolved 30 April 1993
Construction/Loadline
Issued 28 March 1991 Resolved
FOUR CONSECUTIVE FRAMES PORT SIDE SISTERED. #3 FRAME AND SISTER REMOVED AND REPLACED WITH LAMINATED OAK FRAME._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 28 March 1991
Resolved 28 March 1991
Construction/Loadline
Issued 15 May 1989 Resolved
1ST, 2ND, 3RD, AND 4TH STEAM BENT FRAMES CRACKED AFT OF AFT ENGINEROOM BULKHEAD PORTSIDE. MAKE TEMPORY REPAIR TO BROKEN FRAMES TO THE SATISFACTION OFA U.S. COAST GUARD MARINE INSPECTOR PRIOR TO 15 JUNE 1989. PERMANENT RE- PAIR AT NEXT CREDIT DRYDOCKING.
Condition: Unknown
Due 15 May 1989
Resolved 15 May 1989

Casualty record · 1

21 September 2008Routine · role: Involved in a Marine Casualty · 1 injured · activity 3332250
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record