Records from 2016 to 2020. Most recent: inspection, 18 May 2020.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 July 2018
Resolved
01 – 01199 - VESSEL OWNERS MUST PAY THE FEES ASSOCIATED WITH THIS SUBPART, PRIOR TO THE INSPECTION. THE VESSEL WAS FOUND TO BE IN COLLECTION STATUS FOR 2018. 46CFR2.10-20(a) 705C
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 July 2018
Resolution: Proof of payment presented to attending MI.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 25 July 2018
Resolved
02 – 02106 - THE VESSELS HULL SHALL MAINTAIN WATERTIGHT INTEGRITY. THE VESSEL WAS FOUND WITH WATER LEAKING IN THROUGH THE CHINE IN THE PORT SIDE OF THE TANK SPACE. 46CFR176.802(a)(1) 705C
Action required: 705 - Other - as specified
Resolved 25 July 2018
Resolution: Seam compound was used to seal the seam.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 July 2018
Resolved
03 – 13101 – THE VESSEL SHALL BE MAINTAINED IN A CONDITION THAT IS FREE FROM HAZARDS AND UNSAFE PRACTICES. THE JACKET WATER LINE ON THE OUTBOARD SIDE OF THE PORT MAIN ENGINE HAS A STEADY LEAK COMING FROM THE LINE. THIS LEAK IS DRIPPING ONTO OTHER ASSOCIATED MACHINERY, WHILE ALSO PLACING WATER INTO THE BILGE. 46CFR176.25-50(a) 705C
Action required: 705 - Other - as specified
Resolved 25 July 2018
Resolution: repaired
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 July 2018
Resolved
04 – 13101 – THE VESSEL SHALL BE MAINTAINED IN A CONDITION THAT IS FREE FROM HAZARDS AND UNSAFE PRACTICES. THE JACKET WATER LEAK HAS CAUSED SIGNIFICANT CORROSION TO OCCUR ON THE PORT MAIN ENGINE’S OUTBOARD EXHAUST MANIFOLD, CREATING A SITUATION THAT IS HAZARDOUS TO THE CREW AND THE VESSEL. 46CFR176.25-50(a) 705C
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 August 2018
Resolution: Exhaust manifold cleaned up, appears structurally sound.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 25 July 2018
Resolved
05 – 13104 – ALL VESSELS 26 FT. OR GREATER SHALL BE EQUIPPED WITH BILGE PUMPING ARRANGEMENTS FOR ALL WATERTIGHT COMPARTMENTS. THE FIXED POWER PUMPING SYSTEM SHALL BE CAPABLE OF OPERATIONG AT 25 GPM. THE VESSEL CAPTAIN WAS UNABLE TO DEMONSTRATE THE OPERATION OF THE BILGE PUMPING SYSTEM IN THE LAZARETTE SPACE. 46CFR182.25-5(a) AND TABLE182.25-10(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 August 2018
Resolution: Lazarette bilge pumping system operation demonstrated to the attending MI.
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 25 July 2018
Resolved
06 – 14102 – THERE SHALL BE NO ACCUMULATION OF OIL IN THE BILGES OF A VESSEL. THE VESSEL HAD A SIGNIFICANT AMOUNT OF OIL BEING RETAINED IN THE ENGINE ROOM BILGES. ALL BILGES TO BE CLEANED. 46CFR176.25-50(b) 705C
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 August 2018
Resolution: Oil was removed fro E/R bilges, other bilge spaces vacuumed out.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 25 July 2018
Resolved
07 – 02105 - THE VESSEL SHALL BE MAINTAINED IN A CONDITION THAT IS FREE FROM HAZARDS AND UNSAFE PRACTICES. THE RUDDER POSTS AND PORT SIDE SHAFT WERE LEAKING WATER INTO THE VESSELS HULL. EVIDENCE OF THE PACKING MATERIAL FOR THE PORT SIDE SHAFT, WAS DISCOVERED IN THE BILGE. 46CFR176.25-50(a) 705C
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 August 2018
Resolution: The shaft packing was repaired/tightened up, rudder post showed no evidence of leakage.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 July 2018
Resolved
08 – 02108 - WIRING JOINTS AND SPLICES SHALL BE MECHANICALLY SECURE AND MADE INSIDE OF A JUNCTION BOX. THE VESSEL HAD UNAUTHORIZED ELECTRICAL CONNECTIONS MADE OUTSIDE OF A JUNSTION BOX ON THE FORWARD BULKHEAD OF THE ENGINE ROOM. 46CFR183.05-50(b)(1) 705C
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 August 2018
Resolution: Electrical connection has been placed in a junction box.
09 - Working and Living Conditions › 092 - Working Conditions › Holds and tanks safety
Issued 25 July 2018
Resolved
09 – 09106 - THE VESSEL SHALL BE MAINTAINED IN A CONDITION THAT IS FREE FROM HAZARDS AND UNSAFE PRACTICES. THE VESSELS SEWAGE HOLDING TANKS WERE NOT CAPPED, ALLOWING THEM TO VENT FREELY INTO THE ENGINEERING SPACE. 46CFR176.25-50(a) 705C
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 August 2018
Resolution: The sewage tanks were capped/sealed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 25 July 2018
No resolution recorded
10 - 02106 - THE VESSELS HULL SHALL MAINTAIN WATERTIGHT INTEGRITY. THE VESSEL WAS FOUND TO HAVE A GAP IN THE STRUCTURE WHERE THE DECK AND SIDESHELL MEET, ON THE STARBOARD SIDE OF THE TANK SPACE. 46CFR176.802(a)(1)
Temp repairs have been made, complete repair at next credit dry dock.
Action required: 705 - Other - as specified
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 July 2018
Resolved
11 – 02108 – ALL ELECTRICAL INSTALLATIONS SHALL BE TO THE SATISFACTION OF THE OCMI. THE VESSELS CAPTAIN INSTALLED HALLOGEN LIGHTING, MAUALLY RUNNING THE CORD AROUND THE UPPER DECK, THEN, PLUGGING IT INTO AN OUTLET ON THE BRIDGE. ADDITIONALLY, THERE ARE DEAD END WIRES, HANGING IN THE BRIDGE SPACE, ON THE AFT BULKHEAD. 46CFR183.01-15(a) 705C
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 August 2018
Resolution: Halogen lighting removed; dead ends wires placed into an electrical junction box.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 25 July 2018
Resolved
12 – 01203 - EACH SHIP TRANSPORTING MORE THAN SIX PASSENGERS FOR HIRE EQUIPPED WITH A RADIOTELEPHONE STATION, THE RADIO OPERATOR MUST HOLD A MARINE RADIO OPERATOR PERMIT. EACH RADIO OPERATOR MUST OBTAIN A RADIO OPERATORS PERMIT. VESSEL RESTRICTED OT OPERATING WITHIN 1000 FEET OF SHORE. 47CFR80.159 705C
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 August 2018
Resolution: Master obtained a valid FCC Marine Operators permit.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 25 July 2018
Resolved
13 – 11135 – ALL LIFE FLOATS SHALL BE CONSPICUOUSLY MARKED WITH THE NUMBER OF PERSONS ALLOWED. THE 25 PASSENGER LIFE FLOAT DID NOT HAVE THE NUMBER OF PERSONS ALLOWED MARKED ON IT. 46CFR180.20-5(a) 50C
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 1 August 2018
Resolution: The passenger count was marked on the life float.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 25 July 2018
Resolved
14 – 11135 – THE LIGHT AND PAINTER ARE REQUIRED TO BE ATTACHED TO THE PAINTER ATTACHMENT FITTING OR AROUND THE BODY OF THE LIFE FLOAT. THE LIGHT/PAINTER WERE ATTACHED TO BIGHTS FOR THE LIFELINE. 46CFR180.175 50C
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 1 August 2018
Resolution: The attachments were re-done in the correct manner.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 July 2018
Resolved
15 – 13101 - THE VESSEL SHALL BE MAINTAINED IN A CONDITION THAT IS FREE FROM HAZARDS AND UNSAFE PRACTICES. THE INBOARD EXHAUST COOLING LINE OF THE PORT MAIN ENGINE HAS WHAT APPEARS TO HAVE A TEMPORARY REPAIR (SOFT PATCH) MADE TO IT. THE CAUSE FOR THIS TEMPORARY REPAIR NEEDS TO BE ADDRESSED AND RECTIFIED. 46CFR176.25-50(a) 16C
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 August 2018
Resolution: The point in question was not a soft patch, it is a means to prevent chafing between the metal piping and a metal support bracket.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 25 July 2018
Resolved
16 – 11118 – PLACARDS CONTAINING INSTRUCTIONS FOR DONNING AND USING LIFEJACKETS SHALL BE POSTED IN CONSPICUOUS PLACES ON BOARD THE VESSEL, READILY ACCESSIBLE AND VISIBLE TO THE PASSENGERS AND CREW. THE DONNING INSTRUCTIONS ON BOARD THE VESSEL WERE NOT FOR THE LIFEJACKECTS THAT WERE ON THE VESSEL. 46CFR185.516(a) 50C
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 1 August 2018
Resolution: The life jacket donning instructions were of the appropriate type for the life jackets on board the vessel.
Navigation › Electronic Positioning › Radio Direction Finding Device
Issued 19 May 2016
Resolved
REPLACE EPIRB BATTERY WITH NEW ONE. VESSEL LIMITED TO LESS THAN 3 NM
Action required: 705 - Other - as specified
Due 4 June 2016
Resolved 7 June 2016
Resolution: Vessel purchased a new EPIRB battery.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 19 May 2016
Resolved
PLUG HOLES IN AFT LAZARETTE BULKHEAD WHERE WIRES ARE GOING THROUGH
Action required: 705 - Other - as specified
Due 4 June 2016
Resolved 7 June 2016
Resolution: Vessel operator plugged holes in aft bulkhead in the lazarette.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 19 May 2016
Resolved
POST COI AND STABILITY LETTER
Action required: 705 - Other - as specified
Due 4 June 2016
Resolved 7 June 2016
Resolution: Vessel posted COI and Stability letter in common area.