This record may be incomplete: the most recent inspection recorded for this vessel was 21 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard.

Inspection record

Last inspected 26 October 2005
Operational controls None recorded without a removal date
Years with a record 8 calendar years (1998–2005)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

466050
Flag
UNITED STATES
Tonnage
16 - Regulatory (Subpart C or D), Gross Ton 16 - Regulatory (Subpart C or D), Net Ton
Maury page id
psix-466050
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 10

26 October 2005 Administrative Inspection
Administrative · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2523863
24 March 2005 Administrative Inspection
Administrative · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2321950
9 June 2004 Annual Inspection · Hull Examination
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2094701
10 June 2003 Drydock Extension · Annual Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1814784
29 July 2002 Annual Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1653997
5 June 2001 Deficiency Check · COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1370247
12 July 2000 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1052029
3 November 1999 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 799737
19 August 1999 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1361077
10 June 1998 Hull Examination · Inclining Experiment · Deadweight Survey · Initial Certification
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1453412

Deficiency record · 20

Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 10 June 2003 Resolved
Service spare portable fire extinguishers. LEGACY COMPONENT DESC: Service
Due 10 July 2003
Resolved 26 June 2003
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 10 June 2003 Resolved
Provide BI fire extinguisher for rescue boat.
Due 10 July 2003
Resolved 26 June 2003
Pollution Prevention/Response › Prevention Equipment
Issued 10 June 2003 Resolved
Clean oily residue under both winch drums. LEGACY COMPONENT DESC: Fixed Containment
Due 10 July 2003
Resolved 26 June 2003
Electrical › Electric Supply System (service)
Issued 10 June 2003 Resolved
Repair battery charger cable. LEGACY COMPONENT DESC: Battery Charger
Due 10 July 2003
Resolved 26 June 2003
Deck/Cargo › Mooring/Anchoring
Issued 10 June 2003 Resolved
Repair winch control box at stern ramp. LEGACY COMPONENT DESC: Winch
Due 10 July 2003
Resolved 26 June 2003
Electrical › Electrical Distribution System (service)
Issued 29 July 2002 Resolved
Prior to using 110v power repair conduit crossing deck of barge. LEGACY COMPONENT DESC: Conduit
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 August 2002
Resolved 10 June 2003
Stability
Issued 29 July 2002 Resolved
Repair inclinometer LEGACY COMPONENT DESC: Inclinometer
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 August 2002
Resolved 10 June 2003
Engineering › Gasoline Engine (auxiliary)
Issued 29 July 2002 Resolved
Replace gas can cap on outboard fuel tank.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 August 2002
Resolved 10 June 2003
Electrical
Issued 5 June 2001 Resolved
Provide fuses or cicurit breaker on lighting system and ramp motors on barge prior to night operations
Condition: Unknown
Due 11 July 2001
Resolved 11 July 2001
Navigation
Issued 5 June 2001 Resolved
Repair/replace stern light on ferry barge, prior to operating at night.
Condition: Unknown
Due 11 July 2001
Resolved 11 July 2001
Deck/Cargo
Issued 5 June 2001 Resolved
Provide thimble at rope and at 3' of chain at anchors.
Condition: Unknown
Due 11 July 2001
Resolved 11 July 2001
Navigation
Issued 5 June 2001 Resolved
Repair/replace port light on towboat prior to operating at night.
Condition: Unknown
Due 11 July 2001
Resolved 11 July 2001
Lifesaving
Issued 5 June 2001 Resolved
Provide a type I or type III PFD for towboat operator.
Condition: Unknown
Due 11 July 2001
Resolved 11 July 2001
Electrical
Issued 5 June 2001 Resolved
Provide written instructions to the crew to not operate genset when passengers are on board.
Condition: Unknown
Due 11 July 2001
Resolved 11 July 2001
Deck/Cargo
Issued 12 July 2000 Resolved
Provide 100' of anchor line on anchor.
Condition: Unknown
Due 12 July 2000
Resolved 12 July 2000
Lifesaving
Issued 12 July 2000 Resolved
Provide floatable line on life ring.
Condition: Unknown
Due 28 July 2000
Resolved 28 July 2000
Documentation
Issued 12 July 2000 Resolved
Provide logs of training and drills of crew.
Condition: Unknown
Due 12 July 2000
Resolved 12 July 2000
Fire Fighting
Issued 19 August 1999 Resolved
Service or remove excess fire extinguishers without safety wires on pull pins.
Condition: Unknown
Due 19 August 1999
Resolved 19 August 1999
Fire Fighting
Issued 19 August 1999 Resolved
Provide a fire axe.
Condition: Unknown
Due 19 August 1999
Resolved 19 August 1999
Electrical
Issued 19 August 1999 Resolved
Tape over (insulate) all exposed electrical connections.
Condition: Unknown
Due 19 August 1999
Resolved 19 August 1999