SEARCHER is a 1970 passenger vessel (inspected). The Coast Guard has recorded 119 inspections since 1985, most recently in December 2025, along with 153 deficiencies, 1 operational control and 3 casualty investigations between 2001 and 2007.

Records from 1985 to 2025. Most recent: inspection, 17 December 2025.

Built
1970
Last inspected
17 December 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8229717 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WBA7451
Flag
UNITED STATES
367130150, 368400970
Maury page id
psix-46609

Inspections, by type

…with no type recorded27
Years with a record 37 calendar years (1985–2025)
The 119 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)84.4 ft × 23.3 ft × 6.5 ft
Registered tonnagegross 96 / net 73
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDITTMAR&DONALDSON · COSTA MESA, CA, UNITED STATES · built 1970
Hull materialWood
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSAN DIEGO, CA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 22 September 2025 · expires 31 October 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it96 - Regulatory (Subpart C or D), Gross Ton
73 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDP9649MMSI 368400970 · active · compulsorily equipped · granted 16 January 2025, expires 16 January 2035
WBA7451MMSI 367130150 · active · compulsorily equipped · granted 26 August 2016, expires 30 September 2026
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 119

17 December 2025 COI Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8284540
2 December 2025 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8187626
23 January 2025 COI Inspection · Administrative Inspection · Deficiency Check · MTSA/ISPS Verification
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8066974
10 December 2024 Deficiency Check · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8011728
22 January 2024 In-Service Inspection · COI Inspection · MTSA/ISPS Verification
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7840721
6 December 2023 Hull Examination · Deficiency Check · Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7807002
3 May 2023 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7680651
13 April 2023 Administrative Inspection · In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7667998
24 January 2023 COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7623831
6 January 2023 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7609203
16 November 2022 Excursion Permit · Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7595785
7 January 2022 COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7376917
7 December 2021 Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7363620
4 June 2021 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7219015
8 January 2021 Deficiency Check · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7119320
9 December 2020 Administrative Inspection · Drydock Exam · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7108743
5 February 2020 Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6903287
8 January 2020 COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6875778
11 December 2019 Hull Examination · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6839138
20 November 2019 Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6859553
12 October 2019 Deficiency Check · In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6835044
10 January 2019 COI Inspection · MTSA/ISPS Verification · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6606839
6 December 2018 Examination of Repairs · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6572134
10 January 2018 MTSA/ISPS Verification · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6331491
12 December 2017 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6304308
3 January 2017 Security Plan Review - VSP · Deficiency Check · Administrative Inspection · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6064953
14 December 2016 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6052708
6 January 2016 COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5792402
14 December 2015 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5781529
19 October 2015 Construction Oversight · Plan Review "T" Boat · Examination of Repairs
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5760556
8 May 2012 DAPI Audit · Deficiency Check · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4305462
7 April 2009 COI Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3448263
23 May 2008 Deficiency Check · MTSA/ISPS Verification · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3181395
7 May 2008 Internal Structural Exam · Hull Examination · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3181381
16 May 2007 MTSA Verification · COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2915652
25 April 2007 Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2909663
1 March 2007 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3109155
29 June 2006 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2702342
17 May 2006 COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2628824
3 May 2006 Hull Examination · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2616401
24 May 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2367130
24 May 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2367144
19 May 2005 COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2321487
5 May 2005 Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2321465
15 December 2004 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2259868
20 July 2004 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2139600
29 June 2004 MTSA/ISPS Verification
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2115203
25 May 2004 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2077960
21 May 2004 COI Inspection · Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2059797
4 May 2004 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2058895
9 January 2004 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1980947
19 May 2003 COI Inspection · Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1796670
2 May 2003 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1784237
6 December 2002 Drydock Extension
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1715162
10 June 2002 Administrative Inspection
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1628868
9 April 2002 COI Inspection · Hull Examination · Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1602732
2 January 2002 Damage Survey
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1474802
23 November 2001 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1475243
14 November 2001 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 229172
14 November 2001 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 750730
6 September 2001 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1071818
7 May 2001 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1417277
24 April 2001 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1444514
17 May 2000 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1049618
8 May 2000 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1455851
14 April 2000 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1417052
6 April 2000 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 24354
2 February 2000 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 815808
16 June 1999 Damage Survey
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1365449
25 May 1999 Deficiency Check · Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1421673
26 April 1999 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1400989
2 July 1998 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 796455
27 May 1998 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 796446
27 May 1998 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1472422
21 April 1998 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1472423
12 January 1998 Re-Inspection · Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1419894
4 October 1997 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 3977
13 June 1997 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 775363
5 June 1997 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 55676
5 June 1997 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 137137
5 June 1997 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1110374
20 December 1996 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1374819
9 December 1996 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1359310
3 April 1996 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1078724
31 January 1996 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 884134
12 December 1995 COI Inspection · Hull Examination · Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1390171
18 April 1995 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 853680
4 January 1995 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1440891
22 November 1994 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1356919
4 April 1994 Excursion Permit
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 855565
16 December 1993 COI Inspection · Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1439466
6 January 1993 Deficiency Check · COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1354221
30 November 1992 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 829162
4 November 1992 Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1252798
16 October 1992 Damage Survey
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1415772
12 October 1992 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 133889
19 May 1992 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1256304
28 April 1992 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1270979
10 April 1992 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 953410
20 December 1991 Hull Examination · COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 946551
4 January 1991 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 928904
13 December 1990 COI Inspection · Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1233469
22 May 1990 Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 902388
22 May 1990 Hull Examination · COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1211227
10 May 1989 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1348766
4 May 1989 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1203437
19 April 1989 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1345408
12 May 1988 Hull Examination · COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1343718
30 April 1987 Hull Examination · Deficiency Check · Examination of Repairs · COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1000295
3 September 1986 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1313435
14 August 1986 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1307909
18 July 1986 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1295801
13 May 1986 COI Inspection · Credit Drydock · Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 994210
23 January 1986 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 995994
11 December 1985 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1298178
3 June 1985 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1288347
8 May 1985 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 982909
27 March 1985 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 980424
10 January 1985 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 976864

Deficiency record · 153

11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 17 December 2025 Resolved
An adult life jacket must be provided for each person carried on board a vessel. One life jacket was cracked, faded, and in unserviceable condition. Provide 2 additional life jacket in serviceable condition. Reduced passenger count by two.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 February 2026
Resolved 29 January 2026
Resolution: Received photo from owner [name withheld]
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 December 2025 Resolved
A vessel must carry one floating waterlight attached to the ring via corrosion resistant clip with line 3ft to 6ft in length. Light was found inoperable by [name withheld] light and notify local OCMI.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 February 2026
Resolved 29 January 2026
Resolution: Received photo from owner [name withheld]
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 17 December 2025 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up to date: U.S. Coast Pilot or similar publication and Coast Guard Light List. MI observed that the publications were not up to date. Provide up to date publication.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 February 2026
Resolved 29 January 2026
Resolution: Received photo from owner [name withheld]
05 - Radio Communications › N/A - No Subsystem › Distress messages: obligations and procedures
Issued 17 December 2025 Resolved
Vessels operated beyond the 20 nautical mile limitation specified in paragraph (a)(1) of this section, but not more than 100 nautical miles from the nearest land, must be equipped with a MF-DSC frequency transmitter meeting the requirements of § 80.1101(c)(3) and capable of transmitting J3E emission and a receiver capable of reception of J3E emission within the band 1710 to 2850 kHz, in addition to the VHF-DSC radiotelephone installation required by paragraph (a)(1) of this section. Vessel is missing the required MF-DSC frequency transmitter. Vessel is restricted to operating less than 20 nautical miles until MF-DSC frequency transmitter is installed in vessel. 47 CFR 80.905(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 February 2026
Resolved 29 January 2026
Resolution: Received photo from owner [name withheld]
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 December 2025 Resolved
Electrical equipment on a vessel must be installed and maintained to minimize accidental personnel contact with energized parts. Dead end wires found under helm on the bridge. Remove dead end wiring and update electrical plans.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 February 2026
Resolved 29 January 2026
Resolution: Received photo from owner [name withheld]
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 December 2025 Resolved
Each ring life buoy must be marked with Type II retroreflective material approved in accordance with 46 CFR 164.018. 01 life ring buoys on board vessel are missing Type II retroreflective material. 1 life ring buoy retroreflective material was missing. Add approved retroreflective type material to ring buoy.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 February 2026
Resolved 29 January 2026
Resolution: Received photo from owner [name withheld]
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 17 December 2025 Resolved
Each nozzle must be of corrosion resistant material and be ca[able of being changed between a solid stream and a spray pattern. It must also have fittings of brass or other suitable corrosion resistant material that comply with NFPA 1963 or another standard specified by the Commandant. Vessel only had plastic nozzles and a straight stream nozzle onboard. Replace with nozzles meeting the aforementioned requirements.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 February 2026
Resolved 29 January 2026
Resolution: Received photo from owner [name withheld]
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 17 December 2025 Resolved
Emergency lighting must be fitted along the line of escape to the main deck from all passenger and crew accommodation spaces. Add emergency lighting to the emergency escape exiting to the main deck from the galley.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 February 2026
Resolved 29 January 2026
Resolution: Received photo from owner [name withheld]
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 December 2025 Resolved
Each connection to a conductor or terminal part of a conductor must have a pressure type conductor. Vessel was found with unacceptable connections throughout spaces. Exposed wires were found in engine room. Electrical wiring was not adequately protected from moisture of physical damage in Laz. Salt drop was found in Laz on the wiring on the fans in the Laz.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 February 2026
Resolved 29 January 2026
Resolution: Received photo from owner [name withheld]
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 27 January 2025 Resolved
Each vessel that operates on the high seas must have on board a FCC Type Accepted Category 1, 406 MHz EPIRB, installed to automatically float free and activate. Hydrostatic float free device expired. Provide valid hydrostatic device. Cite: 46 CFR 180.64.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 February 2025
Resolution: Received a picture of the newly installed hydro release for the epirb.
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage management plan
Issued 27 January 2025 Resolved
The master or person in charge of a ship to which this section applies shall ensure that the ship is not operated unless a garbage management plan meeting paragraph (b) of this section is on the ship and that each person handling garbage follows the plan. Vessel does not have a garbage management plan posted. Post a garbage management plan in a conspicuous area that can be seen by passengers and crew. To be rectified by 11 February 2025. Cite: 46 CFR 184.702.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 February 2025
Resolved 29 January 2025
Resolution: Received picture of a new posted plan.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 27 January 2025 Resolved
A vessel of more than 65 feet in length must be sufficiently maneuverable, arranged, and equipped to allow the crew to recover a helpless person from the water. Ladder used to execute man overboard drill was not long enough to safely execute the drill. Provide a suitable means to remove an unconscious person from the water. To be rectified by 27 February 2025. Cite: 46 CFR 180.210.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 February 2025
Resolved 31 January 2025
Resolution: Vessel has a modified aluminum ladder that fits on the railing that is sufficient for POB recoveries.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 January 2025 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Bate tank / slammer pump in engine room at bottom of ladder on the starboard side was not secure. Provide adequate mounting for pump. To be rectified by 27 February 2025. Cite: 46 CFR 182.100
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 February 2025
Resolved 29 January 2025
Resolution: Received picture of it properly mounted.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 January 2025 Resolved
Vessel has not been completing safety and security drills quarterly. New drills were conducted to correct on the spot. Cite: 46 CFR 185.520 & 33 CFR 104.230.
Action required: 10 - Deficiency Rectified
Resolved 27 January 2025
Resolution: Corrected on the spot.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 December 2023 Resolved
Voyages subject to SOLAS requirements must undergo a drydock examination once every 12 months. Vessel was unable to complete Sea Trials, to complete credit drydock, prior to departure to home port. Vessel must complete satisfactory Sea Trial prior to carriage of passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 January 2024
Resolution: Conducted satisfactory post dry dock sea trial.
09 - Working and Living Conditions › 091 - Living Conditions › Access/structure
Issued 13 April 2023 Resolved
Small passenger vessels that have overnight accommodations for passengers must comply with the requirements in 46 CFR 177.500; construction/arrangement and means of escape. Your vessel must make the following corrections to meet the regulations: 1. Galley main salon area missing secondary means of Escape. 2. Passenger compartment missing secondary means of Escape. Current secondary egress configuration utilizing a vertical ladder on a vessel of > 65’ is not in compliance with 46 CFR 177.500. Salon does not have secondary means of egress meeting requirements in 46 CFR 177.500
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 16 January 2024
Resolution: Conducted egress drill providing alternate means of compliance.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 7 January 2022 Resolved
All persons employed or engaged onboard vessels to which STCW applies will be issued a medical certificate valid for 2 years. Two (02) crewmembers had expired STCW medical certificates. Provide valid STCW medical certificates for all crewmembers. Crewmembers without valid medical certificates may not serve on international voyages.
Action required: 705 - Other - as specified
Resolved 23 February 2022
Resolution: Provided proof of medical certificate. New expiration date is STCW: 17Feb2024, NATL: 17Feb2027.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 7 January 2022 Resolved
Vessel had insufficient navigational charts for its voyage. Provide sufficient up to date navigation charts for the vessel's intended voyages.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 February 2022
Resolved 1 February 2022
Resolution: Provided proof of updated charts.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 December 2021 Resolved
Voyages subject to SOLAS requirements must undergo a drydock examination once every 12 months. Vessel was unable to complete Sea Trials, to complete credit drydock, prior to departure to home port. Vessel must complete satisfactory Sea Trial to complete drydock prior to carriage of passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 January 2022
Resolution: Conducted satisfactory sea trials.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 January 2021 Resolved
Replace lanyard attaching floating light to ring life buoy.
Action required: 10 - Deficiency Rectified
Due 8 January 2021
Resolved 8 January 2021
Resolution: Def corrected on spot.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 December 2020 Resolved
Voyages subject to SOLAS requirements must undergo a drydock examination once every 12 months. Vessel was unable to complete Sea Trial in order to complete credit drydock prior to departure to home port. Vessel must complete Sea Trial/satisfactory completion of drydock prior to carraige of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 December 2020
Resolved 10 December 2020
Resolution: DDX Completed.
08 - Alarms › N/A - No Subsystem › Engineers' alarm
Issued 8 January 2020 Resolved
AFT lazerette and engine room bilge alarms were non operational at time of inspection.
Action required: 10 - Deficiency Rectified
Due 8 January 2020
Resolved 8 January 2020
Resolution: Repaired on the spot.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 January 2020 Resolved
Topside electrical junction box must be sealed and watertight.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 February 2020
Resolved 24 January 2020
Resolution: Electrical J-box sealed and watertight.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 January 2020 Resolved
Each lifeline on a ring life buoy must be made of buoyant material.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 February 2020
Resolved 24 January 2020
Resolution: New line on life buoy.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 8 January 2020 Resolved
Remove flammabel materials from vessel or place in approved flammable locker.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 February 2020
Resolved 24 January 2020
Resolution: Flammable materials removed from vessel.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 11 December 2019 Resolved
Vessel must complete a sea trial prior to carrying passengers or receiving credit dry dock.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 December 2019
Resolved 3 February 2020
Resolution: Sea trial completed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 October 2019 Resolved
Vessel has been identified as having various A/C electrical modifications since initial certification. Sector San Diego does not have vessels electrical plans on file or current installations do not match what we have on file. Provide a one-line electrical drawing for all A/C switchboards and distribution panels. Include all circuit loads, conductor sizes, and over current protection.
Action required: 705 - Other - as specified
Due 12 January 2020
Resolved 3 February 2020
Resolution: Final AC Electrical drawing submitted and verified onboard as accurate to vessel lay out.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 12 October 2019 Resolved
All escape hatches and emergency exits used as means of escape must be marked on both sides in clearly legible letters that says "EMERGENCY EXIT, KEEP CLEAR". Emergency exit hatch from accommodation space was not marked on the top side in the galley. Mark emergency escape hatch with proper marking on both sides.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 November 2019
Resolved 19 November 2019
Resolution: Corrected.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 12 October 2019 Resolved
While underway or drifting at sea, every vessel shall at all times maintain a proper look-out by sight and hearing. The designated watchmen required by 46 CFR 185.410 cannot preform both roving patrolling and look-out watch simultaneously. Vessel has been instructed to operate with a look-out and watchman while conducting drift operations.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 October 2019
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 12 October 2019 Resolved
Footholds, handholds, ladders and similar means provided to aid escape through emergency exits must be suitable for emergency conditions. Provide additional ladder rungs above main deck at both emergency escapes. 46 CFR 177.500(m)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 November 2019
Resolved 19 November 2019
Resolution: Aft exit hand holds added, forward in galley utilizes drawer handles (no other option).
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 January 2019 Resolved
Repair broken fuel shutoff valve handle @ port/fwd tank.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 January 2019
Resolved 24 January 2019
Resolution: Handle repaired, valve tested operational.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 10 January 2019 Resolved
Replace unapproved plastic fire nozzles with approved type.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 January 2019
Resolved 24 January 2019
Resolution: Owner chose to replace with bronze suicide nozzles.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 10 January 2019 Resolved
Repair inop light for fwd bilge alarm.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 January 2019
Resolved 24 January 2019
Resolution: Tested SAT.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 January 2019 Resolved
Replace expired first aid items.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 January 2019
Resolved 24 January 2019
Resolution: Expired items replaced.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 11 December 2018 Resolved
Vessel directed to complete final portion of drydock examination by conducting underway sea trail upon returning to homeport in San Diego.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 December 2018
Resolved 10 January 2019
Resolution: Conducted satisfactory sea-trials while underway. Inspected all internal spaces while vessel was underway. All found SAT.
Stability › Watertight Integrity › General
Issued 12 December 2017 Resolved
Conduct sea-trial to the satisfaction of the attending Marine Inspector prior to carrying passengers or receiving credit for drydock.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 January 2018
Resolution: Sector San Diego conducted satisfactory sea-trial.
Fire Fighting › Portable CO2 Fire Extinguisher › Condition
Issued 3 January 2017 Resolved
Provide serviceable F/E IVO passageway
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 January 2017
Lifesaving › Lifebuoys › Serviceable
Issued 3 January 2017 Resolved
Provide 03 serviceable Life Rings
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 January 2017
Personnel › Certificates/Documents/Licenses › License, Master
Issued 3 January 2017 Resolved
Provide VSO endorsement prior to operating internationally
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 February 2017
Fire Fighting › Means of Escape › Corridors
Issued 3 January 2017 Resolved
Label bunkroom escape hatches externally
Action required: 705 - Other - as specified
Due 11 February 2017
Resolved 19 January 2017
Engineering › Fuel Oil Service System › Piping
Issued 3 January 2017 Resolved
Label diesel fill pipes
Action required: 705 - Other - as specified
Due 11 February 2017
Resolved 19 January 2017
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 3 January 2017 Resolved
Provide simple instructions for the operation of fixed CO2 system near pull box
Action required: 705 - Other - as specified
Due 11 February 2017
Resolved 19 January 2017
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 3 January 2017 Resolved
Label lifejacket stowage
Action required: 705 - Other - as specified
Due 11 February 2017
Resolved 19 January 2017
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 6 January 2016 Resolved
Original not onboard: Provide original certificate of documentation onboard the vessel.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 January 2016
Resolved 20 January 2016
Resolution: Original now onboard.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 6 January 2016 Resolved
Post EAP substance abuse hotline number in a conspicuous area of the vessel.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 31 January 2016
Resolved 20 January 2016
Resolution: EAP number properly posted.
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 6 January 2016 Resolved
Provide bonding wire for both tank fill pipes.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 31 January 2016
Resolved 31 January 2016
Fire Fighting › Ventilation Systems › Operating Controls
Issued 6 January 2016 Resolved
Unsure vapor barrier on aft engine room bulkhead.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 January 2016
Resolved 31 January 2016
Construction/Loadline › Hull › Keel
Issued 17 December 2015 Resolved
Install (02) keel bolts (cold-rolled steel) at frames 11 and 13 fwd of transom.
Action required: 705 - Other - as specified
Due 18 December 2015
Resolved 12 January 2016
Resolution: Visually inspected keel bolts already installed during COI inspection
Stability › Watertight Integrity › General
Issued 17 December 2015 Resolved
Complete check-ride for credit dry dock. Prior to carrying passengers for hire
Action required: 705 - Other - as specified
Due 8 January 2016
Resolved 12 January 2016
Resolution: Underway drills conducted during COI inspection
Communications › Long Range Identification and Tracking (LRIT) › Transmission Unit
Issued 17 May 2012 Resolved
Vessel required to install and test LRIT. Restricted from international voyage.
Action required: 705 - Other - as specified
Due 17 May 2012
Resolved 11 June 2012
Resolution: CID received confirmation from CLS Amercia that LRIT passed testing.
Lifesaving › Lifeboat Equipment › Radar Transponder
Issued 8 May 2012 Resolved
SART #4000-4999-31000-50999 failed to transmit on radar. Prove proper operation or replace. Restricted from Int'l voyage.
Action required: 705 - Other - as specified
Due 17 May 2012
Resolved 24 May 2012
Resolution: New SART purchased and installed.
Communications › Radio Communications › VHF Radiotelephone
Issued 8 May 2012 Resolved
Batteries for emergency radios (03) expired, replace. Restricted from Int'l voyage.
Action required: 705 - Other - as specified
Due 17 May 2012
Resolved 15 June 2012
Resolution: New batteries on board.
Communications › Radio Communications › EPIRB
Issued 8 May 2012 Resolved
Hydrostatic release for EPIRB is expired, replace. Restricted to 3nm from shore.
Action required: 705 - Other - as specified
Due 17 May 2012
Resolved 24 May 2012
Resolution: New hydrostatic release installed this date.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 8 May 2012 Resolved
Replace expired meds in first aid kits and provide splint.
Action required: 705 - Other - as specified
Due 17 May 2012
Resolved 24 May 2012
Resolution: First aid kits all up to date.
Communications › Radio Communications › Radiotelephone Transceiver (2-27.5 MHz)
Issued 8 May 2012 Resolved
Prove proper operation of SSB, not transmitting. Restricted to 20nm from shore.
Action required: 705 - Other - as specified
Due 17 May 2012
Resolved 24 May 2012
Resolution: SSB operating porperly.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 7 April 2009 Resolved
Renew Alcohol Swabs
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 May 2009
Resolution: Alcohol Swabs were renewed
Fire Fighting › Fire Pumps › Gland Sealing
Issued 30 May 2008 Resolved
Repair excessive fire pump leak at packing.
Action required: 705 - Other - as specified
Due 7 June 2008
Resolved 2 June 2008
Documentation › Logs/Records › Drug Test Records
Issued 23 May 2008 Resolved
Provide current random drug testing crew list.
Action required: 705 - Other - as specified
Due 7 June 2008
Resolved 27 May 2008
Fire Fighting › Ventilation Systems › Exhaust Ducts (Galley Ranges)
Issued 23 May 2008 Resolved
Clean grease build-up in galley hood ducting.
Action required: 705 - Other - as specified
Due 7 June 2008
Resolved 30 May 2008
Documentation › Markings/Placards › Capacity Marking
Issued 23 May 2008 Resolved
Label maximum passengers permitted on upper deck (40) as per COI.
Action required: 705 - Other - as specified
Due 7 June 2008
Resolved 27 May 2008
Fire Fighting › Fire Pumps › Pressure
Issued 23 May 2008 Resolved
Ensure adequate fire pump pressure (60 psi).
Action required: 705 - Other - as specified
Due 7 June 2008
Resolved 30 May 2008
Construction/Loadline › Hull › Transverse Frame
Issued 7 May 2008 Resolved
Address areas of rot on tranverse floor frames in way of shaft boot seals for both main engines, and affect permanent repair.
Action required: 705 - Other - as specified
Due 30 May 2008
Resolved 23 May 2008
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 7 May 2008 Resolved
Ensure fixed CO2 F/F system controls (pressure switches) are located outside the space protected (E/R).
Action required: 705 - Other - as specified
Due 30 November 2008
Resolved 23 May 2011
Resolution: Pressure switches for CO2 system located outside of E/R.
Electrical › Lighting (service) › Lighting Fixture
Issued 16 May 2007 Resolved
Provide suitable guards over 2 lights in engine space (missing covers).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 June 2007
Resolved 21 May 2007
Communications › Radio Communications › Radiotelephone Transceiver (2-27.5 MHz)
Issued 16 May 2007 Resolved
Complete installation of DSC-capable radio as required by 47 CFR. Vessel restricted to nmt 100 nm from shore until corrected.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 May 2007
Resolved 21 May 2007
Navigation › Piloting/Steering › Marine Charts
Issued 16 May 2007 Resolved
Replace/update San Diego Bay Chart (18773), ed. 40, dtd 12/05 with current edition.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 June 2007
Resolved 21 May 2007
Construction/Loadline › Hull › Hull Plating
Issued 3 May 2006 Resolved
Replace One 12 foot plank starboard side forward seam at chine. Plank seam has been repaired/recaulked to many times, permanent repair required.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 May 2006
Resolution: Replaced plank.
Construction/Loadline › Hull › Transverse Frame
Issued 3 May 2006 Resolved
Replacing approximately one hundred fastners - port and starboard sides planks at chine seam - fastners in good shape - loose. Owner pulled loose fastners, utilized W.E.S. T. System and inserted wooden plug. will cut plugs even with vessel skin and will refasten with silcone bronze fasteners. Vessel fastened will silicone bronze.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 May 2006
Resolution: Pulled worn fasteners, plugged holes using wooden plugs and WEST System, drilled and inserted new holes and refastened with narrower/longer silicone bronze fasteners (20 X 6 wood screws).
Electrical › Electrical Distribution System (service) › Wiring
Issued 19 May 2005 Resolved
Loose wires on both the fire pump motor and starboard fuel tank gauges need to be capped and properly secured.
Due 1 June 2005
Resolved 20 May 2005
Resolution: Wires were capped off and secured within the electrical panel.
Engineering › Fuel Oil Service System › Filter
Issued 19 May 2005 Resolved
Starboard generator fuel filter bowl has excess diesel fuel that needs to be cleaned out.
Due 1 June 2005
Resolved 20 May 2005
Resolution: The starboard generator fuel filter bowl was cleaned of excess diesel fuel and new filters installed.
Navigation › Piloting/Steering › Marine Charts
Issued 19 May 2005 Resolved
Vsl has electronic charts of the local area, but hardcopy chart is outdated. A new (current) chart is required.
Due 1 June 2005
Resolved 20 May 2005
Resolution: A new ''hardcopy'' chart for the areas transited was purchased.
Communications › Radio Communications › VHF Radiotelephone
Issued 19 May 2005 Resolved
The original copy of the vsl's safety radiotelephone certificate was not available for inspection. Advised the o/o that a photocopy was not acceptable and the original must be presented.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 May 2005
Resolution: The original safety radiotelephone certificate was presented for verification and filed with the vsl''s other certificates.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 19 May 2005 Resolved
The first aid kit was missing eye-wash solution.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 May 2005
Resolution: New eye-wash solution was purchased along with additional supplies for the kit.
Documentation › Certificates/Documents › Coastwise Load Line Certificate
Issued 21 May 2004 Resolved
Provide new load line certificate after ABS completed survey.
Action required: 705 - Other - as specified
Due 26 May 2004
Resolved 27 May 2004
Engineering › Steering Gear System › Rudder
Issued 21 May 2004 Resolved
Tighten packing glands around rudders IAW 46CFR176.830
Action required: 705 - Other - as specified
Due 28 May 2004
Resolved 27 May 2004
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 21 May 2004 Resolved
Procure new alcohol swab kit IAW 46CFR16.230
Action required: 705 - Other - as specified
Due 28 May 2004
Resolved 27 May 2004
Electrical › Lighting (service)
Issued 19 May 2003 Resolved
Remove wire nuts from both generators in E/R and on the AC unit in forward berthing. IAW 46 CFR 183.340(i) LEGACY COMPONENT DESC: Switch
Due 3 June 2003
Resolved 22 May 2003
Engineering
Issued 19 May 2003 Resolved
Remove or secure Freon bottle from E/R.
Due 3 June 2003
Resolved 22 May 2003
Engineering
Issued 19 May 2003 Resolved
Remove portable Oxy/Acc brazing kit from E/R.
Due 3 June 2003
Resolved 22 May 2003
Engineering
Issued 19 May 2003 Resolved
Install shaft guard cover on shaft of bilge pump.
Due 3 June 2003
Resolved 22 May 2003
Lifesaving › Inflatable Liferafts
Issued 19 May 2003 Resolved
Provide non-metallic spacers between lifefloats.
Due 3 June 2003
Resolved 22 May 2003
Lifesaving › Lifebuoys
Issued 19 May 2003 Resolved
Both port and starboard life rings need to be replaced. IAW 46 CFR 180.202
Due 3 June 2003
Resolved 22 May 2003
Documentation › Certificates/Documents
Issued 19 May 2003 Resolved
Provide and maintain original licences onboard vessel.
Due 3 June 2003
Resolved 22 May 2003
Lifesaving
Issued 19 May 2003 Resolved
SARTS must be labeled with vessels name. IAW 46 CFR 185.604
Due 3 June 2003
Resolved 22 May 2003
Electrical › Electrical Distribution System (service)
Issued 19 May 2003 Resolved
Finish labeling circuit breaker in Galley. IAW 46 CFR 183.220(d)(e) LEGACY COMPONENT DESC: Circuit Breaker
Due 3 June 2003
Resolved 22 May 2003
Lifesaving
Issued 19 May 2003 Resolved
Lifefloat waterlight located at the Bridge doesn't work. Repair or replace.
Due 3 June 2003
Resolved 22 May 2003
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 19 May 2003 Resolved
Provide U.s Coast Guard approved First Aid Kit with current expiration date.
Due 23 May 2003
Resolved 19 May 2003
Lifesaving › Buoyant Apparatus
Issued 9 April 2002 Resolved
Re-rig sea painter on life floats. LEGACY COMPONENT DESC: Sea Painter
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 May 2002
Resolved 7 May 2002
Lifesaving › Lifejacket/PFD (Type I)
Issued 9 April 2002 Resolved
Separate childs PFD's from adults and stencil stowage area. LEGACY COMPONENT DESC: Storage
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 May 2002
Resolved 7 May 2002
Lifesaving › Lifejacket/PFD (Type I)
Issued 9 April 2002 Resolved
Provide life jacket donning placard. LEGACY COMPONENT DESC: Storage
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 May 2002
Resolved 7 May 2002
Operations/Management › Drills/Instruction
Issued 9 April 2002 Resolved
Log crew drills. LEGACY COMPONENT DESC: Log Drills
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 May 2002
Resolved 7 May 2002
Accommodation/Occupational Safety › Sleeping Accommodations
Issued 9 April 2002 Resolved
Provide operable smoke detector in forw. berthing. LEGACY COMPONENT DESC: Berth
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 May 2002
Resolved 7 May 2002
Electrical › Lighting (emergency)
Issued 9 April 2002 Resolved
Provide operable emergy lighting in forw. berth. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 May 2002
Resolved 7 May 2002
Electrical › Electrical Distribution System (service)
Issued 9 April 2002 Resolved
Wire nut and tape or remove dead ended wires in forward starb corner of engine room. LEGACY COMPONENT DESC: Wiring
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 May 2002
Resolved 7 May 2002
Construction/Loadline › Hull
Issued 2 January 2002 Resolved
Vessel is prohibited from carrying passengers pending U. S. Coast Guard damage inspection and repairs. Owner is to relinquish the vessels Certificate of Inspection and is prevented from operating as a passenger vessel until the COI is returned pending USCG authorization. LEGACY COMPONENT DESC: Longitudinal Frame
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 22 January 2002
Lifesaving
Issued 8 May 2000 Resolved
Prior to 20MAY00 provide operational 406 EPIRB. Vessel is restricted to San Diego Bay until EPIRB is replaced.
Condition: Unknown
Due 19 May 2000
Resolved 19 May 2000
Lifesaving
Issued 8 May 2000 Resolved
Properly attach life float to vessel with weak link.
Condition: Unknown
Due 19 May 2000
Resolved 19 May 2000
Lifesaving
Issued 8 May 2000 Resolved
Properly attach life rafts to vessel with weak link.
Condition: Unknown
Due 19 May 2000
Resolved 19 May 2000
Lifesaving
Issued 8 May 2000 Resolved
Replace required number of adult life jackets for intended route. Currentlythere are 18 adult life jackets aboard. Vessel is restricted to no more_x001C_ than 18 adults and 4 children,until life jackets are replaced.
Condition: Unknown
Due 19 May 2000
Resolved 19 May 2000
Lifesaving
Issued 8 May 2000 Resolved
Provide new paddles for life floats.
Condition: Unknown
Due 19 May 2000
Resolved 19 May 2000
Navigation
Issued 8 May 2000 Resolved
Prior to getting vessel underway, reattach and double nut rudder.
Condition: Unknown
Due 19 May 2000
Resolved 19 May 2000
Documentation
Issued 2 February 2000 Resolved
Vessel is limited to not more than 49 passengers on all routes until stability calculations for damage stability are completed and vessel is issued a new stability letter -or- the existing stability letter is validated.
Condition: Unknown
Due 21 June 2000
Resolved 21 June 2000
Fire Fighting
Issued 25 May 1999 Resolved
DEMONSTRATE PROPER OPERATION OF ENGINE ROOM HEAT DETECTION SYSTEM.
Condition: Unknown
Due 28 May 1999
Resolved 3 June 1999
Fire Fighting
Issued 25 May 1999 Resolved
REPLACE O-RINGS AND FLEXIBLE HOSES FOR CO2 TANK CONTROL VALVES._x001C_
Condition: Unknown
Due 28 May 1999
Resolved 3 June 1999
Fire Fighting
Issued 25 May 1999 Resolved
INSTALL ADDITIONAL FIRE EXTINGUISHER IN GALLEY (BII).
Condition: Unknown
Due 28 May 1999
Resolved 3 June 1999
Engineering
Issued 5 June 1997 Resolved
Repair and properly demonstrate operation of main starboard engine. Until repaired, vessel is to not operate with passengers.
Condition: Unknown
Due 5 June 1997
Resolved 5 June 1997
Engineering
Issued 20 December 1996 Resolved
Prove proper operation of lube oil failure alarm on port generator
Condition: Unknown
Due 9 January 1997
Resolved 28 January 1997
Lifesaving
Issued 20 December 1996 Resolved
renew 2 life ring buoys with retroflective tape.
Condition: Unknown
Due 20 December 1996
Resolved 28 January 1997
Lifesaving
Issued 20 December 1996 Resolved
install retroflective tape on life floats.
Condition: Unknown
Due 20 December 1997
Resolved 28 January 1997
Unknown
Issued 20 December 1996 Resolved
post station bill as required by 46CFR185.514._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 9 January 1997
Resolved 28 January 1997
Lifesaving
Issued 20 December 1996 Resolved
Mount life jacket placard in conspicous place as required by 46CFR185.516._x001C__x001C_ _x001C_ _x001C_
Condition: Unknown
Due 9 January 1997
Resolved 28 January 1997
Navigation
Issued 20 December 1996 Resolved
Renew auto pilot link on starboard rudder.
Condition: Unknown
Due 9 January 1997
Resolved 28 January 1997
Construction/Loadline
Issued 9 December 1996 Resolved
PROPERLY TREAT ROT LOCATED ON THE #8 FRAME LOCATED ON THE PORT SIDE AFT OF THE FORWARD BULKHEAD IN THE ENGINE COMPARTMENT.
Condition: Unknown
Due 18 December 1996
Resolved 18 December 1996
Construction/Loadline
Issued 9 December 1996 Resolved
PROPERLY REPAIR THREE CHECKED FRAMES LOCATED IN BUNK ROOM NUMBER NINE IN THE FORWARD BUNK COMPARTMENT.
Condition: Unknown
Due 18 December 1996
Resolved 18 December 1996
Navigation
Issued 12 December 1995 Resolved
Provide current edition of Tidal Current tables, Tide tables, Light List.
Condition: Unknown
Due 12 December 1995
Resolved 12 December 1995
Lifesaving
Issued 12 December 1995 Resolved
Stencil PFD storage locker with correct numbers of adult and childs life preservers.
Condition: Unknown
Due 14 December 1995
Resolved 8 January 1996
Documentation
Issued 12 December 1995 Resolved
Provide waste disposal plan as required by MARPOL V._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 14 December 1995
Resolved 8 January 1996
Engineering
Issued 12 December 1995 Resolved
Provide 30x30 inch flame screen on port and starboard fuel tank vents._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 14 December 1995
Resolved 8 January 1996
Fire Fighting
Issued 12 December 1995 Resolved
Replace 1.5 inch hose on port firehose station._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 14 December 1995
Resolved 8 January 1996
Navigation
Issued 12 December 1995 Resolved
Prove proper operation of all around anchor light._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 14 December 1995
Resolved 8 January 1996
Accommodation/Occupational Safety
Issued 12 December 1995 Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 14 December 1995
Resolved 14 December 1995
Construction/Loadline
Issued 12 December 1995 Resolved
Replace valve handles on port and starboard main engine cooling water sea suction._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 14 December 1995
Resolved 14 December 1995
Electrical
Issued 12 December 1995 Resolved
Prove proper operation of volt meter on starboard genset._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 14 December 1995
Resolved 8 January 1996
Engineering
Issued 12 December 1995 Resolved
Prove proper operation of lube oil failure alarm on starboard main engine._x001C__x001C_ _x001C_ _x001C_
Condition: Unknown
Due 14 December 1995
Resolved 8 January 1996
Fire Fighting
Issued 12 December 1995 Resolved
Provide suitable length of suction hose for hand fire pump.
Condition: Unknown
Due 14 December 1995
Resolved 8 January 1996
Engineering
Issued 12 December 1995 Resolved
Provide plans and a list of materials for the newly installed fuel transfersystem in the engine room.
Condition: Unknown
Due 14 December 1995
Resolved 14 December 1995
Electrical
Issued 16 October 1992 Resolved
INSTALL REFRIGERATION APPLIANCE (FREEZER) IN WAY OF AFT OF THE PILOT HOUSE IN ACCORDANCE WITH 46 CFR 111.77 AND 111.79 AS APPLICABLE.
Condition: Unknown
Due 16 October 1992
Resolved 16 October 1992
Documentation
Issued 20 December 1991 Resolved
PROVIDE ALL REQUIRED RADIO EQUIPMENT OUTLINED IN 47CFR89.905(a)(3), OR OBTAIN AN EXEMPTION FROM FCC. VESSEL ROUTE LIMITED TO NO MORE THAN 100 NAUTICAL MILES FROM THE NEAREST LAND UNTIL THIS REQUIREMENT IS CLEARED.
Condition: Unknown
Due 20 December 1991
Resolved 20 December 1991
Lifesaving
Issued 13 December 1990 Resolved
UNTIL SUCH TIME AS REQUIRED LIFE RAFTS ARE PLACED ABOARD, MAXIMUM PERSONS AALLOWED SHALL BE 48 ON A ROUTE NOT MORE THAN 20 MILES FROM A HARBOR OF SAFEREFUGE OR 24 PERSONS MAXIMUM ON OCEANS ROUTE. MSO SAN DIEGO IS TO BE INFORMED WHEN RAFTS ARE ABOARD TO ALLOW INSPECTION OF INSTALLATION.
Condition: Unknown
Due 13 December 1990
Resolved 13 December 1990
Fire Fighting
Issued 22 May 1990 Resolved
PROVIDE NOZZLE FOR THE FIRE HOSE OF THE SECONDARY POWER FIRE PUMP.
Condition: Unknown
Due 22 May 1990
Resolved 22 May 1990
Engineering
Issued 22 May 1990 Resolved
PROVIDE PROPER FLAME SHIELD BOWL ON TWO FUEL OIL FILTER IN THE E/R.
Condition: Unknown
Due 22 May 1990
Resolved 22 May 1990
Engineering
Issued 22 May 1990 Resolved
PROVIDE ANOTHER POWER BILGE PUMP WITH AN ALTERNATE MEANS OF POWER, IN ADDITION TO THE REQUIRED PRIMARY BILGE PUMP.
Condition: Unknown
Due 22 May 1990
Resolved 22 May 1990
Documentation
Issued 22 May 1990 Resolved
PROVIDE ANNUAL FCC SURVEY ON RADIO TELEPHONE INSTALLATION FOR SOLAS EXEMPTION.
Condition: Unknown
Due 22 May 1990
Resolved 22 May 1990
Electrical
Issued 22 May 1990 Resolved
PROVE THE PROPER OPERATION OF THE EMERGENCY LIGHTS IN THE FORWARD AND AFT BUNK ROOMS BELOW THE MAIN DECK.
Condition: Unknown
Due 22 May 1990
Resolved 22 May 1990
Accommodation/Occupational Safety
Issued 22 May 1990 Resolved
PROVIDE LOCKING DEVICE TO THE OVERBOARD DISCHARGE VALVE ON THE MARINE SANITATION DEVICE SYSTEM.
Condition: Unknown
Due 22 May 1990
Resolved 22 May 1990
Engineering
Issued 22 May 1990 Resolved
PROVE THE PROPER OPERATION OF THE BILGE LEVEL ALARM IN WAY OF AFT LAZARETTE
Condition: Unknown
Due 22 May 1990
Resolved 22 May 1990
Lifesaving
Issued 22 May 1990 Resolved
PROVIDE AND PROPERLY STOW THE REQUIRED LIFE RAFTS ON BOARD.
Condition: Unknown
Due 22 May 1990
Resolved 22 May 1990
Unknown
Issued 22 May 1990 Resolved
PROPERLY MOUNT THE TWO AUXILIARY PUMPS LOCATED P & S IN THE ENGINE ROOM.
Condition: Unknown
Due 22 May 1990
Resolved 22 May 1990
Navigation
Issued 4 May 1989 Resolved
PROVIDE TWO(2) ADDITIONAL BLACK BALL DAY SHAPES.
Condition: Unknown
Due 4 May 1989
Resolved 4 May 1989
Navigation
Issued 4 May 1989 Resolved
PROVIDE INLAND/INTERNATIONAL RULES OF THE ROAD PUBLICATIONS.
Condition: Unknown
Due 4 May 1989
Resolved 4 May 1989
Navigation
Issued 4 May 1989 Resolved
PROVIDE A NEW MAGNETIC COMPASS DEVIATION CARD.
Condition: Unknown
Due 4 May 1989
Resolved 4 May 1989
Lifesaving
Issued 4 May 1989 Resolved
REPLACE WORN OUT LINES TO ONE OF THE RING LIFE BUOYS.
Condition: Unknown
Due 4 May 1989
Resolved 4 May 1989
Electrical
Issued 4 May 1989 Resolved
REPLACE COVER FOR THE ELECTRICAL CONTROL OF THE HOT WATER HEATER.
Condition: Unknown
Due 4 May 1989
Resolved 4 May 1989
Electrical
Issued 4 May 1989 Resolved
REMOVE LIGHT THAT WAS IMPROPERLY WIRED TO A JUNCTION BOX IN THE HOT WATER HEATER SPACE.
Condition: Unknown
Due 4 May 1989
Resolved 4 May 1989
Electrical
Issued 4 May 1989 Resolved
REPLACE COVER FOR THE PRESSURE SWITCH OF THE WATER PUMP IN THE HOT WATER HEATER SPACE.
Condition: Unknown
Due 4 May 1989
Resolved 4 May 1989
Lifesaving
Issued 4 May 1989 Resolved
PROVIDE LAUNCHING INSTRUCTION PLACARDS FOR THE INFLATABLE LIFERAFTS.
Condition: Unknown
Due 4 May 1989
Resolved 4 May 1989
Construction/Loadline
Issued 12 May 1988 Resolved
INSTAL CAPTURE DEVICES ON ALL FLUSH DECK HATCHES.
Condition: Unknown
Due 12 May 1988
Resolved 12 May 1988
Documentation
Issued 30 April 1987 Resolved
PROVIDE (FCC) RADIO TELEPHONY SAFTEY CERTIFICATE ENDORSEMENT.
Condition: Unknown
Due 30 April 1987
Resolved 30 April 1987
Construction/Loadline
Issued 30 April 1987 Resolved
PROVIDE LABEL FOR STBD FIRE STATION.
Condition: Unknown
Due 30 April 1987
Resolved 30 April 1987
Lifesaving
Issued 30 April 1987 Resolved
REPLACE BATTERY IN RING LIFE BUOY FLOAT LIGHT.
Condition: Unknown
Due 30 April 1987
Resolved 30 April 1987
Construction/Loadline
Issued 30 April 1987 Resolved
RECAULK STBD TRANSOM TO BOTTOM CONNECTION.
Condition: Unknown
Due 30 April 1987
Resolved 30 April 1987
Construction/Loadline
Issued 13 May 1986 Resolved
SUBMIT FOR APPROVAL,PLANS FOR INSTALLATION OF A SUITABLE MARINE SANITATION DEVICE
Condition: Unknown
Due 13 May 1986
Resolved 13 May 1986
Documentation
Issued 13 May 1986 Resolved
SOLAS VOYAGES ARE PROHIBITED PENDING RECEIPT OF FCC EXEMPTION LETTER OF REG 3 CHAPTER 4
Condition: Unknown
Due 13 May 1986
Resolved 13 May 1986

Casualty record · 3

23 November 2001Routine · role: Involved in a Marine Casualty · activity 1475243
29 June 2006Routine · role: Involved in a Marine Casualty · activity 2702342
1 March 2007Routine · role: Involved in a Marine Casualty · 1 injured · activity 3109155
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.