MAURY USCG vessel records
← All vessels

SEARCHER

Built
1970
Last inspected
17 December 2025
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 17 December 2025
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

8229717
WBA7451
Flag
UNITED STATES
Maury page id
psix-46609

Documentation record

Registered dimensions (L × B × D)84.4 ft × 23.3 ft × 6.5 ft
Registered tonnagegross 96 / net 73
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDITTMAR&DONALDSON · COSTA MESA, CA, UNITED STATES · built 1970
Hull materialWood
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSAN DIEGO, CA
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 22 September 2025 · expires 31 October 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it96 - Regulatory (Subpart C or D), Gross Ton
73 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 28 inspections, each with its date, unit and type; 47 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 28

17 December 2025 COI Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8284540
2 December 2025 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8187626
23 January 2025 COI Inspection · Administrative Inspection · Deficiency Check · MTSA/ISPS Verification
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8066974
10 December 2024 Deficiency Check · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8011728
22 January 2024 In-Service Inspection · COI Inspection · MTSA/ISPS Verification
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7840721
6 December 2023 Hull Examination · Deficiency Check · Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7807002
3 May 2023 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7680651
13 April 2023 Administrative Inspection · In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7667998
24 January 2023 COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7623831
6 January 2023 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7609203
16 November 2022 Excursion Permit · Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7595785
7 January 2022 COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7376917
7 December 2021 Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7363620
4 June 2021 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7219015
8 January 2021 Deficiency Check · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7119320
9 December 2020 Administrative Inspection · Drydock Exam · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7108743
5 February 2020 Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6903287
8 January 2020 COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6875778
11 December 2019 Hull Examination · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6839138
20 November 2019 Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6859553
12 October 2019 Deficiency Check · In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6835044
10 January 2019 COI Inspection · MTSA/ISPS Verification · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6606839
6 December 2018 Examination of Repairs · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6572134
10 January 2018 MTSA/ISPS Verification · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6331491
12 December 2017 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6304308
3 January 2017 Security Plan Review - VSP · Deficiency Check · Administrative Inspection · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6064953
14 December 2016 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6052708
6 January 2016 COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5792402

Deficiency record · 47

11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 17 December 2025 Resolved
An adult life jacket must be provided for each person carried on board a vessel. One life jacket was cracked, faded, and in unserviceable condition. Provide 2 additional life jacket in serviceable condition. Reduced passenger count by two.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 February 2026
Resolved 29 January 2026
Resolution: Received photo from owner [name withheld]
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 December 2025 Resolved
A vessel must carry one floating waterlight attached to the ring via corrosion resistant clip with line 3ft to 6ft in length. Light was found inoperable by [name withheld] light and notify local OCMI.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 February 2026
Resolved 29 January 2026
Resolution: Received photo from owner [name withheld]
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 17 December 2025 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up to date: U.S. Coast Pilot or similar publication and Coast Guard Light List. MI observed that the publications were not up to date. Provide up to date publication.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 February 2026
Resolved 29 January 2026
Resolution: Received photo from owner [name withheld]
05 - Radio Communications › N/A - No Subsystem › Distress messages: obligations and procedures
Issued 17 December 2025 Resolved
Vessels operated beyond the 20 nautical mile limitation specified in paragraph (a)(1) of this section, but not more than 100 nautical miles from the nearest land, must be equipped with a MF-DSC frequency transmitter meeting the requirements of § 80.1101(c)(3) and capable of transmitting J3E emission and a receiver capable of reception of J3E emission within the band 1710 to 2850 kHz, in addition to the VHF-DSC radiotelephone installation required by paragraph (a)(1) of this section. Vessel is missing the required MF-DSC frequency transmitter. Vessel is restricted to operating less than 20 nautical miles until MF-DSC frequency transmitter is installed in vessel. 47 CFR 80.905(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 February 2026
Resolved 29 January 2026
Resolution: Received photo from owner [name withheld]
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 December 2025 Resolved
Electrical equipment on a vessel must be installed and maintained to minimize accidental personnel contact with energized parts. Dead end wires found under helm on the bridge. Remove dead end wiring and update electrical plans.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 February 2026
Resolved 29 January 2026
Resolution: Received photo from owner [name withheld]
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 December 2025 Resolved
Each ring life buoy must be marked with Type II retroreflective material approved in accordance with 46 CFR 164.018. 01 life ring buoys on board vessel are missing Type II retroreflective material. 1 life ring buoy retroreflective material was missing. Add approved retroreflective type material to ring buoy.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 February 2026
Resolved 29 January 2026
Resolution: Received photo from owner [name withheld]
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 17 December 2025 Resolved
Each nozzle must be of corrosion resistant material and be ca[able of being changed between a solid stream and a spray pattern. It must also have fittings of brass or other suitable corrosion resistant material that comply with NFPA 1963 or another standard specified by the Commandant. Vessel only had plastic nozzles and a straight stream nozzle onboard. Replace with nozzles meeting the aforementioned requirements.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 February 2026
Resolved 29 January 2026
Resolution: Received photo from owner [name withheld]
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 17 December 2025 Resolved
Emergency lighting must be fitted along the line of escape to the main deck from all passenger and crew accommodation spaces. Add emergency lighting to the emergency escape exiting to the main deck from the galley.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 February 2026
Resolved 29 January 2026
Resolution: Received photo from owner [name withheld]
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 December 2025 Resolved
Each connection to a conductor or terminal part of a conductor must have a pressure type conductor. Vessel was found with unacceptable connections throughout spaces. Exposed wires were found in engine room. Electrical wiring was not adequately protected from moisture of physical damage in Laz. Salt drop was found in Laz on the wiring on the fans in the Laz.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 February 2026
Resolved 29 January 2026
Resolution: Received photo from owner [name withheld]
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 27 January 2025 Resolved
Each vessel that operates on the high seas must have on board a FCC Type Accepted Category 1, 406 MHz EPIRB, installed to automatically float free and activate. Hydrostatic float free device expired. Provide valid hydrostatic device. Cite: 46 CFR 180.64.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 February 2025
Resolution: Received a picture of the newly installed hydro release for the epirb.
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage management plan
Issued 27 January 2025 Resolved
The master or person in charge of a ship to which this section applies shall ensure that the ship is not operated unless a garbage management plan meeting paragraph (b) of this section is on the ship and that each person handling garbage follows the plan. Vessel does not have a garbage management plan posted. Post a garbage management plan in a conspicuous area that can be seen by passengers and crew. To be rectified by 11 February 2025. Cite: 46 CFR 184.702.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 February 2025
Resolved 29 January 2025
Resolution: Received picture of a new posted plan.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 27 January 2025 Resolved
A vessel of more than 65 feet in length must be sufficiently maneuverable, arranged, and equipped to allow the crew to recover a helpless person from the water. Ladder used to execute man overboard drill was not long enough to safely execute the drill. Provide a suitable means to remove an unconscious person from the water. To be rectified by 27 February 2025. Cite: 46 CFR 180.210.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 February 2025
Resolved 31 January 2025
Resolution: Vessel has a modified aluminum ladder that fits on the railing that is sufficient for POB recoveries.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 January 2025 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Bate tank / slammer pump in engine room at bottom of ladder on the starboard side was not secure. Provide adequate mounting for pump. To be rectified by 27 February 2025. Cite: 46 CFR 182.100
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 February 2025
Resolved 29 January 2025
Resolution: Received picture of it properly mounted.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 January 2025 Resolved
Vessel has not been completing safety and security drills quarterly. New drills were conducted to correct on the spot. Cite: 46 CFR 185.520 & 33 CFR 104.230.
Action required: 10 - Deficiency Rectified
Resolved 27 January 2025
Resolution: Corrected on the spot.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 December 2023 Resolved
Voyages subject to SOLAS requirements must undergo a drydock examination once every 12 months. Vessel was unable to complete Sea Trials, to complete credit drydock, prior to departure to home port. Vessel must complete satisfactory Sea Trial prior to carriage of passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 January 2024
Resolution: Conducted satisfactory post dry dock sea trial.
09 - Working and Living Conditions › 091 - Living Conditions › Access/structure
Issued 13 April 2023 Resolved
Small passenger vessels that have overnight accommodations for passengers must comply with the requirements in 46 CFR 177.500; construction/arrangement and means of escape. Your vessel must make the following corrections to meet the regulations: 1. Galley main salon area missing secondary means of Escape. 2. Passenger compartment missing secondary means of Escape. Current secondary egress configuration utilizing a vertical ladder on a vessel of > 65’ is not in compliance with 46 CFR 177.500. Salon does not have secondary means of egress meeting requirements in 46 CFR 177.500
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 16 January 2024
Resolution: Conducted egress drill providing alternate means of compliance.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 7 January 2022 Resolved
All persons employed or engaged onboard vessels to which STCW applies will be issued a medical certificate valid for 2 years. Two (02) crewmembers had expired STCW medical certificates. Provide valid STCW medical certificates for all crewmembers. Crewmembers without valid medical certificates may not serve on international voyages.
Action required: 705 - Other - as specified
Resolved 23 February 2022
Resolution: Provided proof of medical certificate. New expiration date is STCW: 17Feb2024, NATL: 17Feb2027.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 7 January 2022 Resolved
Vessel had insufficient navigational charts for its voyage. Provide sufficient up to date navigation charts for the vessel's intended voyages.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 February 2022
Resolved 1 February 2022
Resolution: Provided proof of updated charts.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 December 2021 Resolved
Voyages subject to SOLAS requirements must undergo a drydock examination once every 12 months. Vessel was unable to complete Sea Trials, to complete credit drydock, prior to departure to home port. Vessel must complete satisfactory Sea Trial to complete drydock prior to carriage of passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 January 2022
Resolution: Conducted satisfactory sea trials.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 January 2021 Resolved
Replace lanyard attaching floating light to ring life buoy.
Action required: 10 - Deficiency Rectified
Due 8 January 2021
Resolved 8 January 2021
Resolution: Def corrected on spot.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 December 2020 Resolved
Voyages subject to SOLAS requirements must undergo a drydock examination once every 12 months. Vessel was unable to complete Sea Trial in order to complete credit drydock prior to departure to home port. Vessel must complete Sea Trial/satisfactory completion of drydock prior to carraige of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 December 2020
Resolved 10 December 2020
Resolution: DDX Completed.
08 - Alarms › N/A - No Subsystem › Engineers' alarm
Issued 8 January 2020 Resolved
AFT lazerette and engine room bilge alarms were non operational at time of inspection.
Action required: 10 - Deficiency Rectified
Due 8 January 2020
Resolved 8 January 2020
Resolution: Repaired on the spot.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 January 2020 Resolved
Topside electrical junction box must be sealed and watertight.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 February 2020
Resolved 24 January 2020
Resolution: Electrical J-box sealed and watertight.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 January 2020 Resolved
Each lifeline on a ring life buoy must be made of buoyant material.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 February 2020
Resolved 24 January 2020
Resolution: New line on life buoy.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 8 January 2020 Resolved
Remove flammabel materials from vessel or place in approved flammable locker.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 February 2020
Resolved 24 January 2020
Resolution: Flammable materials removed from vessel.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 11 December 2019 Resolved
Vessel must complete a sea trial prior to carrying passengers or receiving credit dry dock.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 December 2019
Resolved 3 February 2020
Resolution: Sea trial completed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 October 2019 Resolved
Vessel has been identified as having various A/C electrical modifications since initial certification. Sector San Diego does not have vessels electrical plans on file or current installations do not match what we have on file. Provide a one-line electrical drawing for all A/C switchboards and distribution panels. Include all circuit loads, conductor sizes, and over current protection.
Action required: 705 - Other - as specified
Due 12 January 2020
Resolved 3 February 2020
Resolution: Final AC Electrical drawing submitted and verified onboard as accurate to vessel lay out.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 12 October 2019 Resolved
All escape hatches and emergency exits used as means of escape must be marked on both sides in clearly legible letters that says "EMERGENCY EXIT, KEEP CLEAR". Emergency exit hatch from accommodation space was not marked on the top side in the galley. Mark emergency escape hatch with proper marking on both sides.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 November 2019
Resolved 19 November 2019
Resolution: Corrected.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 12 October 2019 Resolved
While underway or drifting at sea, every vessel shall at all times maintain a proper look-out by sight and hearing. The designated watchmen required by 46 CFR 185.410 cannot preform both roving patrolling and look-out watch simultaneously. Vessel has been instructed to operate with a look-out and watchman while conducting drift operations.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 October 2019
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 12 October 2019 Resolved
Footholds, handholds, ladders and similar means provided to aid escape through emergency exits must be suitable for emergency conditions. Provide additional ladder rungs above main deck at both emergency escapes. 46 CFR 177.500(m)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 November 2019
Resolved 19 November 2019
Resolution: Aft exit hand holds added, forward in galley utilizes drawer handles (no other option).
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 January 2019 Resolved
Repair broken fuel shutoff valve handle @ port/fwd tank.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 January 2019
Resolved 24 January 2019
Resolution: Handle repaired, valve tested operational.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 10 January 2019 Resolved
Replace unapproved plastic fire nozzles with approved type.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 January 2019
Resolved 24 January 2019
Resolution: Owner chose to replace with bronze suicide nozzles.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 10 January 2019 Resolved
Repair inop light for fwd bilge alarm.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 January 2019
Resolved 24 January 2019
Resolution: Tested SAT.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 January 2019 Resolved
Replace expired first aid items.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 January 2019
Resolved 24 January 2019
Resolution: Expired items replaced.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 11 December 2018 Resolved
Vessel directed to complete final portion of drydock examination by conducting underway sea trail upon returning to homeport in San Diego.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 December 2018
Resolved 10 January 2019
Resolution: Conducted satisfactory sea-trials while underway. Inspected all internal spaces while vessel was underway. All found SAT.
Stability › Watertight Integrity › General
Issued 12 December 2017 Resolved
Conduct sea-trial to the satisfaction of the attending Marine Inspector prior to carrying passengers or receiving credit for drydock.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 January 2018
Resolution: Sector San Diego conducted satisfactory sea-trial.
Fire Fighting › Portable CO2 Fire Extinguisher › Condition
Issued 3 January 2017 Resolved
Provide serviceable F/E IVO passageway
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 January 2017
Lifesaving › Lifebuoys › Serviceable
Issued 3 January 2017 Resolved
Provide 03 serviceable Life Rings
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 January 2017
Personnel › Certificates/Documents/Licenses › License, Master
Issued 3 January 2017 Resolved
Provide VSO endorsement prior to operating internationally
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 February 2017
Fire Fighting › Means of Escape › Corridors
Issued 3 January 2017 Resolved
Label bunkroom escape hatches externally
Action required: 705 - Other - as specified
Due 11 February 2017
Resolved 19 January 2017
Engineering › Fuel Oil Service System › Piping
Issued 3 January 2017 Resolved
Label diesel fill pipes
Action required: 705 - Other - as specified
Due 11 February 2017
Resolved 19 January 2017
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 3 January 2017 Resolved
Provide simple instructions for the operation of fixed CO2 system near pull box
Action required: 705 - Other - as specified
Due 11 February 2017
Resolved 19 January 2017
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 3 January 2017 Resolved
Label lifejacket stowage
Action required: 705 - Other - as specified
Due 11 February 2017
Resolved 19 January 2017
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 6 January 2016 Resolved
Original not onboard: Provide original certificate of documentation onboard the vessel.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 January 2016
Resolved 20 January 2016
Resolution: Original now onboard.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 6 January 2016 Resolved
Post EAP substance abuse hotline number in a conspicuous area of the vessel.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 31 January 2016
Resolved 20 January 2016
Resolution: EAP number properly posted.
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 6 January 2016 Resolved
Provide bonding wire for both tank fill pipes.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 31 January 2016
Resolved 31 January 2016
Fire Fighting › Ventilation Systems › Operating Controls
Issued 6 January 2016 Resolved
Unsure vapor barrier on aft engine room bulkhead.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 January 2016
Resolved 31 January 2016

Ownership record