Records from 1981 to 2006. Most recent: inspection, 23 August 2006.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 45
23 August 2006
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2757423
31 October 2003
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1939678
24 February 2003
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1749359
30 July 2002
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1654992
25 October 2001
Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1425232
1 October 2001
Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1389497
20 July 2001
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 74962
17 June 2001
Damage Survey
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1065221
15 August 2000
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1053479
14 August 2000
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 821504
3 January 2000
Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1463541
29 July 1999
Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1361024
3 November 1998
Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1411759
3 November 1997
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1466480
3 July 1997
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1461813
13 November 1996
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1093143
30 October 1996
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1396610
3 November 1995
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1390148
3 November 1994
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1403849
25 February 1994
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1379919
28 December 1993
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1419233
21 June 1993
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 842306
13 April 1993
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 672956
13 April 1993
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 672957
17 March 1993
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 838711
24 February 1993
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1354263
18 May 1992
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1473061
29 April 1992
Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1354140
28 April 1992
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 63909
28 February 1992
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 955947
4 October 1991
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1251317
1 October 1991
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1248824
13 March 1991
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 901236
19 September 1989
COI Inspection · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1333910
22 September 1988
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1043550
20 April 1988
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1344352
28 September 1987
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1344789
17 October 1986
Hull Examination · COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1018397
7 February 1986
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1299985
30 August 1985
Credit Drydock
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1297611
13 March 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 978892
16 February 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1279671
25 February 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1276844
27 August 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1271115
9 March 1981
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1276348
Personnel › Certificates/Documents/Licenses
Issued 1 October 2001
Resolved
PROVIDE ONBOARD FCC OPERATOR'S PERMIT. LEGACY COMPONENT DESC: FCC OPERATOR''S PERMIT
Due 2 January 2002
Resolved 25 October 2001
Accommodation/Occupational Safety › Medical/First Aid
Issued 1 October 2001
Resolved
PROVIDE ONBOARD 1ST AID KIT IAW 46 CFR 184.710. LEGACY COMPONENT DESC: 1ST AID KIT
Due 2 January 2002
Resolved 25 October 2001
Lifesaving › Hand Flares
Issued 1 October 2001
Resolved
PROVIDE ON BOARD PYROTECHNICS IAW 46 CFR 180.68 (a)(1)&(2). LEGACY COMPONENT DESC: Quantity
Due 2 January 2002
Resolved 25 October 2001
Communications › Radio Communications
Issued 1 October 2001
Resolved
PROVIDE ON BOARD EMERGENCY BROADCAST PLACARD IAW 184.506 & 184.510 LEGACY COMPONENT DESC: EMERGENCY BROADCAST PLACARD
Due 2 January 2002
Resolved 25 October 2001
Construction/Loadline › Hull
Issued 1 October 2001
Resolved
REPAIR 7 FRACTURED WELDS IN LAZERETTE AND 3 FRACTURED WELDS IN FOREPEAK. LEGACY COMPONENT DESC: Weld
Due 1 January 2002
Resolved 25 October 2001
Lifesaving › Buoyant Apparatus
Issued 1 October 2001
Resolved
REPAIR WATERLIGHT ON LIFE FLOAT. LEGACY COMPONENT DESC: WATER LIGHT
Due 1 November 2001
Resolved 25 October 2001
Navigation
Issued 17 June 2001
Resolved
Dive survey revealed rudder damage that occurred as a result of grounding/beaching 12-17JUN01. Proceed to drydock for bottom survey and permanent repairs.
Condition: Unknown
Due 17 June 2001
Resolved 17 June 2001
Engineering
Issued 17 June 2001
Resolved
Dive survey revealed that struts were damaged during grounding/beaching 12-17JUN01. Proceed to drydock for bottom survey and permanent repairs.
Condition: Unknown
Due 17 June 2001
Resolved 17 June 2001
Engineering
Issued 17 June 2001
Resolved
Dive survey revealed that both propellers were damaged during grounding/beaching 12-17JUN01. Proceed to drydock for bottom survey an permanent repairs.
Condition: Unknown
Due 17 June 2001
Resolved 17 June 2001
Unknown
Issued 14 August 2000
Resolved
Prove proper operation of the starboard main engine.
Condition: Unknown
Due 14 August 2000
Resolved 14 August 2000
Electrical
Issued 30 October 1996
Resolved
REMOVE EXTENSION CORD LOCATED IN COMPRESSOR ROOM (TO REEFER).
Condition: Unknown
Due 30 October 1996
Resolved 30 October 1996
Engineering
Issued 30 October 1996
Resolved
PROVE PROPER OPERATION OF STBD REMOTE FUEL SHUTOFF VALVE.
Condition: Unknown
Due 30 October 1996
Resolved 30 October 1996
Electrical
Issued 30 October 1996
Resolved
REMOVE AND MAKE PERMANENT BILGE PUMP WIRING.
Condition: Unknown
Due 30 October 1996
Resolved 30 October 1996
Documentation
Issued 30 October 1996
Resolved
PROVIDE PROOF OF PARTICIPATION IN DRUG TESTING PROGRAM.
Condition: Unknown
Due 30 October 1996
Resolved 30 October 1996
Electrical
Issued 30 October 1996
Resolved
REMOVE DEADEND WIRING LOCATED IN COMPRESSOR ROOM.
Condition: Unknown
Due 30 October 1996
Resolved 30 October 1996
Electrical
Issued 30 October 1996
Resolved
PERMANENTLY WIRE BATTERY CHARGER.
Condition: Unknown
Due 30 October 1996
Resolved 30 October 1996
Navigation
Issued 30 October 1996
Resolved
REPLACE STEERING RAM NUTS AND BOLTS PRIOR TO VESSEL DEPARTING.
Condition: Unknown
Due 30 October 1996
Resolved 31 October 1996
Construction/Loadline
Issued 30 October 1996
Resolved
INSTALL RETAINING LANYARDS ON ALL WX DECK HATCHES.
Condition: Unknown
Due 30 October 1996
Resolved 30 October 1996
Engineering
Issued 30 October 1996
Resolved
REPAIR BENT AND LEAKING STBD SHAFT BY 30 NOV 96.
Condition: Unknown
Due 30 October 1996
Resolved 30 October 1996
Navigation
Issued 30 October 1996
Resolved
REPAIR LEAK IN HYDRAULIC LINE TO STEERING LOCATED AFT OF STBD MDE IN_x001C_ ENGINE ROOM.
Condition: Unknown
Due 30 October 1996
Resolved 30 October 1996
Electrical
Issued 24 February 1993
Resolved
RENEW BATTERY BOX IN ENGINE ROOM TO THE SATISFACTION OF THE ATTENDING CG_x001C_ MARINE INSPECTOR. REF: 46 CFR 183.05-20(d)
Condition: Unknown
Due 24 February 1993
Resolved 24 February 1993
Electrical
Issued 24 February 1993
Resolved
PROVE OPERATION OF AMMETER ON ELECTRICAL PANEL FOR GENERATOR TO THE SATIS-_x001C_FACTION OF THE ATTENDING CG MARINE INSPECTOR. REF: 46 CFR 183.10-5(g)
Condition: Unknown
Due 24 February 1993
Resolved 24 February 1993
Construction/Loadline
Issued 24 February 1993
Resolved
RE-ATTACH ANTI-ROTATION BARS TO TAILSHAFT STUFFING BOXES TO THE SATIS- FACTION OF THE ATTENDING CG MARINE INSPECTOR.
Condition: Unknown
Due 24 February 1993
Resolved 24 February 1993
Construction/Loadline
Issued 24 February 1993
Resolved
RENEW WASTED PORTION OF BOTTOM LONGITUDINAL FLANGE FRAME IN ENGINE ROOM_x001C_ PORT SIDE TO THE SATISFACTION OF THE ATTENDING CG MARINE INSPECTOR.
Condition: Unknown
Due 24 February 1993
Resolved 24 February 1993
Accommodation/Occupational Safety
Issued 24 February 1993
Resolved
RENEW BUG SCREEN FOR POTABLE WATER VENT TO THE SATISFACTION OF THE ATTEND-_x001C_ING CG MARINE INSPECTOR. REF: USPHS PUBLICATION NO. 393 SECT A.7
Condition: Unknown
Due 24 February 1993
Resolved 24 February 1993
Engineering
Issued 24 February 1993
Resolved
PROVE OPERATION OF REACH RODS TO FUEL TANKS TO THE SATISFACTION OF THE_x001C_ ATTENDING CG MARINE INSPECTOR. REF: 46 CFR 182.20-40(b)(3)
Condition: Unknown
Due 24 February 1993
Resolved 24 February 1993
Construction/Loadline
Issued 29 April 1992
Resolved
PROCEED WITHOUT DELAY TO SUPERIOR SHIPYARD, GOLDEN MEADOW, LA TO EFFECT_x001C_ PERMANENT REPAIRS TO DAMAGE IN WAY OF PORT SIDE BOW- APPROX. 2' ABOVE WATERLINE.
Condition: Unknown
Due 10 May 1992
Resolved 18 May 1992