Behind this panel: 5 inspections, each with its date, unit and type; 9 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Inspection history · 5
3 February 2022
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7390341
16 March 2019
Ballast Water Examination · COC-TVE Renew · ISPS II Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6622848
2 January 2018
Deficiency Check
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6333717
27 February 2017
ISPS II Exam · COC-TVE Renew
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6094942
15 March 2016
Deficiency Check
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 5833348
01 - Certificates & Documentation › 011 - Ships Certificates › International Oil Pollution Prevention (IOPP)
Issued 16 March 2019
Resolved
AN IOPP CERT SHALL BE ISSUED AFTER AN INITIAL OR RENEWAL SURVEY IAW PROVISIONS OF REGUALTION 6 OF THIS ANNEX. VESSEL'S IOPP CERT DOES NOT ACCURATELY REFLECT PUMPING, PIPING, AND DISCHARGE ARRANGEMENTS (OVERBOARD DISCHARGE).
MARPOL ANNEX I REG 7.1
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 April 2019
Resolved 1 July 2019
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 16 March 2019
Resolved
ANY REQUIRED FIXED ALARM SYSTEM WITH MANUALLY OPERATED CALL POINTS SHALL BE CAPABLE OF IMMEDIATE OPERATION. MANUAL FIRE ALARM IN GALLEY HAD NO WAY TO BREAK GLASS AND FIRE ALARM IN PASSAGEWAY OUTSIDE OF CCR WAS MISSING GLASS PLATE.
97 SOLAS II-2 REG 13.1.1
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 April 2019
Resolved 1 July 2019
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 16 March 2019
Resolved
HAND FLARES AND SMOKE FLARES SHALL BE IN WATER RESISTANT CONTAINER. CONTAINER CCOULD NOT BE LOCATED ON BOARD.
97 SOLAS III REG 36.1.1
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 April 2019
Resolved 1 April 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 March 2019
Resolved
CABLES/WIRING SHALL BE INSTALLED TO AVBOID CHAFFING AND OTHER AMGE. VISIBLE CABLE BREAKDOWN IN FRAMO HYDRAULIC LINE AND EMERGENCY FIRE PUMP LINE.
97 SOLAS II-1 REG 45.5.5
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2019
Resolved 1 April 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 March 2019
Resolved
ELECTRICAL INSTALLIONS SHALL BE SUCH THAT SAFETY OF PASSENGERS, CREW, AND SHIP FROM ELECTRICAL HAZARDS. THE MOTOR CONTROLLERS IN SEPERATOR ROOM ARE MISSING DISCONNECT SWITCH HANDLE.
MARPOL REG 34.16
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 April 2019
Resolved 1 April 2019
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 16 March 2019
Resolved
TANKERS MUST HAVE ODME ARRANGEMENT. VESSEL'S ODME IS INOPERABLE.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 April 2019
Resolved 3 February 2022
Resolution: Recieved class report attesting to proper operation of the ODME.
Communications › Alarms/Indicators › Fire Alarm
Issued 27 February 2017
Resolved
Manually operated call points complying with the fire safety system code shall be installed at control stations. The call box located at the port side transfer area had broken glass and was mounted to the bracked with plastic zip-ties.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 26 March 2017
Resolved 7 January 2018
Resolution: New call box had been installed.
Deck/Cargo › Holds/Tanks › Liquid Level Gaging
Issued 27 February 2017
Resolved
Overfill alarm (98%) is required to be audible and visual at the cargo transfer area and deck area. The audible alarm is not audible on the deck area.
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 February 2017
Resolved 7 January 2018
Resolution: All alarms were audible and visual upon inspection.
Engineering › Reduction Gearing/Clutches › Bearing, Line Shaft
Issued 15 March 2016
Resolved
1499-OTHER(PROP.& AUX. MACHINERY)-SHIP SHALL BE MAINTAINED IN COMPLIANCE WITH THE STRUCTURAL, MECHANICAL, AND ELECTRICAL REQUIREMENTS OF A CLASSIFICATION SOCIETY WHICH IS RECOGNIZED BY THE ADMINISTRATION. THE REDUCTION GEAR BEARING HOUSING ON THE PTO SHAFT FAILED DURING TRANSIT AND REQUIRED REPAIR.-SOLAS 74(04CONS) CHP. II-1 REG 3-1
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 15 March 2016
Resolved 30 January 2017
Resolution: Received class report attesting to repairs on reduction gear.