MAURY USCG vessel records
← All vessels

VOYAGEUR II

VOYAGEUR II is a 1970 passenger vessel (inspected). The Coast Guard has recorded 15 inspections since 2016, most recently in April 2026, along with 11 deficiencies.

Records from 2016 to 2026. Most recent: inspection, 1 April 2026.

Built
1970
Last inspected
1 April 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

WBS5271
Flag
UNITED STATES
Maury page id
psix-46624

Inspections, by type

Years with a record 11 calendar years (2016–2026)
The 15 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Documentation record

Registered dimensions (L × B × D)60.5 ft × 16.1 ft × 3.8 ft
Registered tonnagegross 40 / net 26
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSANDUSKY, OH, UNITED STATES · built 1970
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portDULUTH, MN
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationValid · issued 20 February 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it40 - Regulatory (Subpart C or D), Gross Ton
26 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 15

1 April 2026 Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 8343985
1 July 2025 Administrative Inspection · DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 8170428
24 April 2025 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 8127613
27 June 2024 Periodic Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7947289
6 June 2023 Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7706633
6 June 2023 DAPI Audit · Administrative Inspection
Administrative · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7713107
26 July 2022 DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7510282
24 May 2021 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7205115
21 April 2021 COI Inspection · DAPI Audit · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7186226
29 April 2020 Examination of Repairs · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 6945752
22 April 2020 COI Inspection · Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 6934719
16 July 2019 DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 6765997
13 July 2018 DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 6481438
11 July 2017 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 6204435
6 June 2016 Annual Inspection
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 5899436

Deficiency record · 11

11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 July 2025 Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. Child life jackets must be segregated from adult life jackets. 46 CFR 180.78(5) 16c
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2025
Resolved 22 July 2025
Resolution: Received satisfactory photograph of lifejacket partition.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 July 2025 Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 25 millimeters (1 inch) high indicating purpose of the valve and direction of operation. Main engine fuel shutoff must be marked. 46 CFR 185.608
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2025
Resolved 22 July 2025
Resolution: Received satisfactory photograph of emergency fuel shutoff label.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 July 2025 Resolved
Junction boxes, connection boxes, and outlet boxes, for use in damp or wet locations shall be of watertight construction. Outlet box on forward bulkhead of starboard engine room is missing a cover. 46 CFR 183.10-20(k) OLD T 16c
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2025
Resolved 22 July 2025
Resolution: Received satisfactory photograph of outlet cover.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 30 April 2025 Resolved
A vessel must undergo a drydock examination and Internal structural exam at least once every five years. Vessels Drydock due date is 30APR25, and vessel has not received drydock credit. Vessel must get a drydock inspection prior to operating with passengers. 46CFR176.600(a)(2)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 May 2025
Resolution: Vessel received credit drydock and ISE.
09 - Working and Living Conditions › 092 - Working Conditions › Fitness for duty - intoxication
Issued 5 May 2021 Resolved
The alcohol testing kits are expired and require renewal. The vessel's route exceeds their capability to have alcohol testing completed within two hours of a marine casualty.
Action required: 705 - Other - as specified
Due 27 May 2021
Resolved 24 May 2021
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 5 May 2021 Resolved
The navigation charts are out of date and not maintained with current navigation information. New charts for the operating are required.
Action required: 705 - Other - as specified
Due 27 May 2021
Resolved 24 May 2021
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 5 May 2021 Resolved
The Coast Pilot and Light List are out of date and not maintained with updated corrections. Current applicable sections of the Coast Pilot and Light List are required to be provided on board the vessel.
Action required: 705 - Other - as specified
Due 27 May 2021
Resolved 24 May 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 5 May 2021 Resolved
There are two bilge system suction lines in the engine room that are not equipped with strainers and check valves. Strainers and check valves are required to be installed.
Action required: 705 - Other - as specified
Due 27 May 2021
Resolved 24 May 2021
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 5 May 2021 Resolved
The flashlight required near the engine room access is missing. Provide a flashlight stowed near the engine room access.
Action required: 705 - Other - as specified
Due 27 May 2021
Resolved 24 May 2021
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 5 May 2021 Resolved
The life jacket donning placards are missing. Post life jacket donning placards for each style of life jacket on board the vessel.
Action required: 705 - Other - as specified
Due 27 May 2021
Resolved 24 May 2021
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 22 April 2020 Resolved
Prior to carrying passengers, complete an inspection for certification.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 April 2021
Resolved 21 April 2021

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.