MAURY USCG vessel records Sign in
← All vessels

VOYAGEUR II

VOYAGEUR II is a 1970 passenger vessel (inspected). The Coast Guard has recorded 52 inspections since 1985, most recently in April 2026, along with 62 deficiencies.

Records from 1985 to 2026. Most recent: inspection, 1 April 2026.

Built
1970
Last inspected
1 April 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WBS5271
Flag
UNITED STATES
366420240
Maury page id
psix-46624

Inspections, by type

…with no type recorded5
Years with a record 36 calendar years (1985–2026)
The 52 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)60.5 ft × 16.1 ft × 3.8 ft
Registered tonnagegross 40 / net 26
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
Builderbuilder not recorded · SANDUSKY, OH, UNITED STATES · built 1970
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portDULUTH, MN
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationValid · issued 20 February 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it40 - Regulatory (Subpart C or D), Gross Ton
26 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WBS5271MMSI 366420240 · active · compulsorily equipped · granted 13 March 2018, expires 22 April 2028
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 52

1 April 2026 Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 8343985
1 July 2025 Administrative Inspection · DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 8170428
24 April 2025 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 8127613
27 June 2024 Periodic Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7947289
6 June 2023 Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7706633
6 June 2023 DAPI Audit · Administrative Inspection
Administrative · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7713107
26 July 2022 DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7510282
24 May 2021 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7205115
21 April 2021 COI Inspection · DAPI Audit · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7186226
29 April 2020 Examination of Repairs · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 6945752
22 April 2020 COI Inspection · Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 6934719
16 July 2019 DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 6765997
13 July 2018 DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 6481438
11 July 2017 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 6204435
6 June 2016 Annual Inspection
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 5899436
24 June 2014 Annual Inspection
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 4896994
29 May 2008 Annual Inspection
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 3221071
30 April 2007 Deficiency Check
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 2919203
18 April 2007 Hull Examination · Annual Inspection
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 2910813
26 April 2006 Annual Inspection
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 2633717
2 August 2005 Administrative Inspection
Administrative · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 2449184
29 April 2005 COI Inspection
Physical examination · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 2345567
29 April 2004 Annual Inspection
Physical examination · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 2055136
28 April 2003 Re-Inspection
Physical examination · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 1782059
10 April 2002 Hull Examination · Annual Inspection
Physical examination · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 1610416
30 April 2001 Re-Inspection
Physical examination · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 1466214
1 May 2000 COI Inspection
Physical examination · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 817008
29 April 1999 Hull Examination · Re-Inspection
Physical examination · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 1402860
30 April 1998 Re-Inspection
Physical examination · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 1123919
2 May 1997 Damage Survey · COI Inspection · Examination of Repairs
Physical examination · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 1100862
29 April 1996 Re-Inspection · Deficiency Check
Physical examination · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 1080154
5 May 1995 Re-Inspection
Physical examination · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 1181562
23 November 1994 Type not recorded
No type recorded · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 1143190
2 May 1994 COI Inspection
Physical examination · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 858660
27 April 1994 Hull Examination · Damage Survey
Physical examination · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 854578
1 June 1993 Type not recorded
No type recorded · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 93699
3 May 1993 Re-Inspection
Physical examination · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 838895
6 May 1992 Re-Inspection
Physical examination · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 1254889
5 October 1991 Examination of Repairs
Physical examination · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 940065
5 October 1991 Damage Survey
Physical examination · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 1472290
3 May 1991 Type not recorded
No type recorded · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 909776
29 April 1991 COI Inspection
Physical examination · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 1307799
3 May 1990 Re-Inspection
Physical examination · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 903440
3 May 1989 Re-Inspection · Hull Examination
Physical examination · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 1346954
18 April 1989 Hull Examination
Physical examination · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 907976
5 May 1988 COI Inspection
Physical examination · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 1036161
19 February 1988 Administrative
Administrative · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 1023431
4 May 1987 Re-Inspection
Physical examination · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 1016879
8 May 1986 Re-Inspection
Physical examination · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 1297207
28 March 1986 Credit Drydock
Administrative · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 997642
10 June 1985 Type not recorded
No type recorded · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 1289613
10 May 1985 Type not recorded
No type recorded · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 981064

Deficiency record · 62

11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 July 2025 Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. Child life jackets must be segregated from adult life jackets. 46 CFR 180.78(5) 16c
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2025
Resolved 22 July 2025
Resolution: Received satisfactory photograph of lifejacket partition.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 July 2025 Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 25 millimeters (1 inch) high indicating purpose of the valve and direction of operation. Main engine fuel shutoff must be marked. 46 CFR 185.608
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2025
Resolved 22 July 2025
Resolution: Received satisfactory photograph of emergency fuel shutoff label.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 July 2025 Resolved
Junction boxes, connection boxes, and outlet boxes, for use in damp or wet locations shall be of watertight construction. Outlet box on forward bulkhead of starboard engine room is missing a cover. 46 CFR 183.10-20(k) OLD T 16c
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2025
Resolved 22 July 2025
Resolution: Received satisfactory photograph of outlet cover.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 30 April 2025 Resolved
A vessel must undergo a drydock examination and Internal structural exam at least once every five years. Vessels Drydock due date is 30APR25, and vessel has not received drydock credit. Vessel must get a drydock inspection prior to operating with passengers. 46CFR176.600(a)(2)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 May 2025
Resolution: Vessel received credit drydock and ISE.
09 - Working and Living Conditions › 092 - Working Conditions › Fitness for duty - intoxication
Issued 5 May 2021 Resolved
The alcohol testing kits are expired and require renewal. The vessel's route exceeds their capability to have alcohol testing completed within two hours of a marine casualty.
Action required: 705 - Other - as specified
Due 27 May 2021
Resolved 24 May 2021
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 5 May 2021 Resolved
The navigation charts are out of date and not maintained with current navigation information. New charts for the operating are required.
Action required: 705 - Other - as specified
Due 27 May 2021
Resolved 24 May 2021
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 5 May 2021 Resolved
The Coast Pilot and Light List are out of date and not maintained with updated corrections. Current applicable sections of the Coast Pilot and Light List are required to be provided on board the vessel.
Action required: 705 - Other - as specified
Due 27 May 2021
Resolved 24 May 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 5 May 2021 Resolved
There are two bilge system suction lines in the engine room that are not equipped with strainers and check valves. Strainers and check valves are required to be installed.
Action required: 705 - Other - as specified
Due 27 May 2021
Resolved 24 May 2021
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 5 May 2021 Resolved
The flashlight required near the engine room access is missing. Provide a flashlight stowed near the engine room access.
Action required: 705 - Other - as specified
Due 27 May 2021
Resolved 24 May 2021
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 5 May 2021 Resolved
The life jacket donning placards are missing. Post life jacket donning placards for each style of life jacket on board the vessel.
Action required: 705 - Other - as specified
Due 27 May 2021
Resolved 24 May 2021
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 22 April 2020 Resolved
Prior to carrying passengers, complete an inspection for certification.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 April 2021
Resolved 21 April 2021
Electrical › Electric Supply System (service) › Cable
Issued 24 June 2014 Resolved
Power supply cable to the port engine starter not properly supported and beginning to chafe on engine support frame.
Condition: Improper/Lack of Maintenance
Due 24 July 2014
Resolved 24 June 2014
Resolution: Installed two support clamps and chaffing gear on the cable
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 24 June 2014 Resolved
Fire extinguisher in passenger cabin bracket not mounted on bulkhead
Condition: Improper Installation
Due 24 June 2014
Resolved 24 June 2014
Resolution: Corrected on the spot. remounted fire extinguisher.
Engineering › Fuel Oil Service System › Hose
Issued 29 May 2008 Resolved
Port main engine F/O return hose is of improper material & ends not double clamped. Replace IAW46CFR182.720 (Old 182.20-40).
Condition: Improper Installation
Due 30 June 2008
Resolved 21 May 2009
Engineering › Fuel Oil Service System › Hose
Issued 29 May 2008 Resolved
F/O return hose on stbd main engine not properly fire sleeved. Properly sleeve hose IAW SAE J-1942-1 via 46 CFR 182.720
Condition: Improper Installation
Due 30 June 2008
Resolved 21 May 2009
Electrical › Electrical Distribution System (service) › Junction Box
Issued 29 May 2008 Resolved
Wiring for head pump wire nutted in the open, nuts not secured. Provide J-box and secure nuts IAW 46 CFR 183.340(g) (old 46CFR18305-50.
Condition: Improper Installation
Due 30 June 2008
Resolved 21 May 2009
Engineering › Fuel Oil Service System › Piping
Issued 29 May 2008 Resolved
F/O supply to generator leaking IWO supply valve. Repair leak. 46 CFR 176.830
Condition: Improper/Lack of Maintenance
Due 30 June 2008
Resolved 21 May 2009
Construction/Loadline › Hull › Transverse Frame
Issued 18 April 2007 Resolved
>> FOUR FRAMES FORWARD OF FUEL TANK WERE ALL OBSERVED TO BE CRACKED ALONG MIDSECTION WELDS. IT IS PRESUMED THAT FIFTH FRAME FORWARD OF FUEL TANK IS ALSO CRACKED, HOWEVER IT WAS NOT READILY VISIBLE DUE TO SEPTIC TANKS. SEPTIC TANKS NEED TO ME REMOVED TO ASSESS FRAME INTEGRITY AND MAKE NECESSARY REPAIRS. >> FRAME BELOW PORT ENGINE MOUNT WAS CRACKED. NEEDS REPAIR.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 May 2007
Resolved 20 April 2007
Lifesaving › Lifefloat › Paddle
Issued 18 April 2007 Resolved
Renew Lifefloat paddles. Paddles to be IAW 46 CFR 180.15-5(b) (Old T)
Action required: 705 - Other - as specified
Due 26 May 2007
Resolved 30 April 2007
Resolution: All paddles replaced with new ones.
Engineering › Sea-water System (primary cooling) › Piping
Issued 18 April 2007 Resolved
Renew R/W cooling hoses on MDE exhaust manifolds.
Action required: 705 - Other - as specified
Due 25 May 2007
Resolved 30 April 2007
Resolution: Hoses renewed.
Engineering › Bilge Water Management System › Not Operational
Issued 29 April 2005 Resolved
Prove proper operation of aft bilge pump.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 May 2005
Resolution: Bilge pump operation tested. Test Sat.
Engineering › Fuel Oil Service System › Hose
Issued 29 April 2005 Resolved
Replace main engine suction and discharge fuel hoses.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 May 2005
Resolution: Suction and discharge hoses replaced.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 29 April 2005 Resolved
Replace ring buoy light and provide removable lanyard.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 May 2005
Resolution: Ring buoy light replaced.
Lifesaving › Buoyant Apparatus › Lifeline
Issued 29 April 2005 Resolved
Replace lifefloat painter.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 May 2005
Resolution: Painter replaced.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 29 April 2005 Resolved
Install blanks on forward breaker panel.
Condition: Unknown
Action required: 705 - Other - as specified
Due 7 May 2005
Resolved 6 May 2005
Resolution: Blanks installed in Breaker panel.
Electrical › Electrical Distribution System (service) › Wiring
Issued 29 April 2005 Resolved
Install metallic supports on all wire runs.
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 May 2005
Resolved 6 May 2005
Resolution: Metallic supports installed on wire runs.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 29 April 2005 Resolved
Replace expired medicines.
Condition: Unknown
Due 7 May 2005
Resolved 6 May 2005
Resolution: Expired medications replaced.
Electrical › Electric Supply System (service) › Battery Installation
Issued 29 April 2005 Resolved
Permanently mount generator starting battery.
Condition: Unknown
Due 15 May 2005
Resolved 6 May 2005
Resolution: Generator battery secured to deck.
Lifesaving › Rigid Liferafts
Issued 29 April 2004 Resolved
Stencil vessel name on lifefloat paddles
Condition: Unknown
Due 5 May 2004
Resolved 4 May 2004
Resolution: Stenciled paddles.
Stability › Incline Test › General
Issued 29 April 2004 Resolved
Conduct a simplified stability test IAW 46 CFR 171.030
Action required: 705 - Other - as specified
Due 30 April 2005
Resolved 6 May 2005
Resolution: Owner operator requested to keep weather restrictions on COI instead of conducting stability test.
Electrical › Electrical Distribution System (service)
Issued 29 April 2004 Resolved
Install cover on open cicuit breaker in forward cabin breaker panel. LEGACY COMPONENT DESC: Circuit Breaker
Action required: 705 - Other - as specified
Due 5 May 2004
Resolved 4 May 2004
Resolution: Installed blanks on circuit panel.
Engineering › Steering Gear System
Issued 29 April 2004 Resolved
Repair fractured stbd rudder post brackets and repair as original stbd steering arm end play. LEGACY COMPONENT DESC: Rudder
Condition: Unknown
Action required: 705 - Other - as specified
Due 5 May 2004
Resolved 4 May 2004
Resolution: Welded Rudder post brackets and replace bolt on steering arm.
Navigation › Piloting/Steering
Issued 28 April 2003 Resolved
Acquire corrected, updated charts 14968, 14967, 14966, 14976. LEGACY COMPONENT DESC: Marine Charts
Due 10 May 2003
Resolved 5 May 2003
Construction/Loadline › Hull
Issued 28 April 2003 Resolved
Repair cracking at the base of starboard side handrail at gangway. LEGACY COMPONENT DESC: Sheerstrake
Due 10 May 2003
Resolved 5 May 2003
Resolution: Crack repaired.
Engineering
Issued 28 April 2003 Resolved
Secure breather assembly to hull at port engine outboard. Assembly is loose.
Due 10 May 2003
Resolved 5 May 2003
Fire Fighting › Combustible Materials
Issued 28 April 2003 Resolved
Free bilges of any oily debris in port and starboard engine compartments.
Due 10 May 2003
Resolved 5 May 2003
Lifesaving › Lifejacket/PFD (General)
Issued 28 April 2003 Resolved
Replace 44 adult and 5 child life jackets (type I) to reset total life jackets as specified in certificate of inspection. LEGACY COMPONENT DESC: Quantity
Due 10 May 2003
Resolved 5 May 2003
Operations/Management › Drug and Alcohol Testing
Issued 28 April 2003 Resolved
Complete DAPI inspection.
Due 10 May 2003
Resolved 10 May 2003
Resolution: To be conducted during inspection of M/V WENONAH
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 10 April 2002 Resolved
Electrical outlet cover in generator space missing.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 April 2002
Resolved 22 April 2002
Resolution: Electrical outlet cover in generator space replaced.
Electrical › Electrical Distribution System (emergency)
Issued 10 April 2002 Resolved
Emergency lighting in the aft passenger lounge inoperable.
Condition: Unknown
Action required: 705 - Other - as specified
Due 22 April 2002
Resolved 22 April 2002
Resolution: Repaired emergency lighting in the aft passenger lounge.
Lifesaving › Rigid Liferafts
Issued 10 April 2002 Resolved
Life float paddles missing stenciling. LEGACY COMPONENT DESC: Markings
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 April 2002
Resolved 22 April 2002
Resolution: Re-stenciled Life float paddles.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 10 April 2002 Resolved
Port main engine tachometer inop.
Action required: 705 - Other - as specified
Due 22 April 2002
Resolved 22 April 2002
Resolution: Repaired port main engine tachometer.
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 10 April 2002 Resolved
Double hose clamps missing from port main engine r/w system.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 April 2002
Resolved 22 April 2002
Resolution: Added double hose clamps to port main engine r/w system.
Operations/Management › Navigation Safety › Proper Use of Navigation/Anchor Lights
Issued 10 April 2002 Resolved
All around white nav. light inoperable
Action required: 705 - Other - as specified
Due 22 April 2002
Resolved 22 April 2002
Resolution: Repaired the all around white nav. light
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 10 April 2002 Resolved
Light guards in galley and head missing.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 April 2002
Resolved 22 April 2002
Resolution: Replaced missing light guards in the galley and head.
Construction/Loadline
Issued 1 May 2000 Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 5 May 2000
Resolved 3 May 2000
Unknown
Issued 29 April 1996 Resolved
PRIOR TO CARRYING PASSENGERS ON BOARD, MAKE FULLY OPERABLE PASSENGER COMPARTEMENT PUBLIC ADDRESS SYSTEM.
Condition: Unknown
Due 13 May 1996
Resolved 9 May 1996
Electrical
Issued 29 April 1996 Resolved
PRIOR TO 15MAY96, MAKE SEARCHLIGHT OPERABLE.
Condition: Unknown
Due 15 May 1996
Resolved 9 May 1996
Electrical
Issued 29 April 1996 Resolved
MAKE ELECTRICAL CONNECTIONS TO AIR HORN COMPRESSOR WATERTIGHT OR MOVE COMPRESSOR TO INTERIOR LOCATION.
Condition: Unknown
Due 15 May 1996
Resolved 9 May 1996
Electrical
Issued 29 April 1996 Resolved
INSTALL LIGHTBULB GUARD OVER BARE LIGHT BULB IN WOMEN'S HEAD.
Condition: Unknown
Due 15 May 1996
Resolved 9 May 1996
Navigation
Issued 5 May 1995 Resolved
PRIOR TO GETTING UNDERWAY WITH PASSENGERS ON BOARD, BUT NO LATER THAN 11 MAY 1995, REPAIR TO OPERABLE CONDITION THE VESSELS AIR HORN. NOTIFY THIS OFFICE WHEN COMPLETED SO THAT MARINE INSPECTOR CAN WITNESS ITS OPERATION.
Condition: Unknown
Due 11 May 1995
Resolved 8 May 1995
Construction/Loadline
Issued 29 April 1991 Resolved
Prior to departure from Superior, and prior to carrying any passengers for hire, make permanent repairs to the leaking weld in the port transom. Repairs shall be to the satisfaction of a USCG Marine Inspector.
Condition: Unknown
Due 29 April 1991
Resolved 29 April 1991
Navigation
Issued 29 April 1991 Resolved
Prior to departure from Superior, and prior to carrying any passengers for hire, stiffen the support structure for the hydraulic steering ram. If steel is used, the steel and aluminum must be suitably isolated. Repairs are to be to the satisfaction of a USCG Marine Inspector.
Condition: Unknown
Due 29 April 1991
Resolved 29 April 1991
Lifesaving
Issued 29 April 1991 Resolved
Prior to departure from Superior, and prior to carrying any passengers for hire, a satisfactory fire drill, and a satisfactory man overboard drill shall be conducted while underway, in the presence of a USCG Marine Inspector.
Condition: Unknown
Due 29 April 1991
Resolved 29 April 1991
Electrical
Issued 29 April 1991 Resolved
Provide a voltmeter, ammeter, and frequency meter to service both 110V generator sets. One set of meters properly installed will meet this requirement. This requirement shall be completed within 30 days to the satisfaction of a USCG Marine Inspector.
Condition: Unknown
Due 29 April 1991
Resolved 29 April 1991
Engineering
Issued 10 May 1985 Resolved
INSTALL A FIXED POWER DRIVEN BILGE PUMP AND SYSTEMN (46CFR182.25)
Condition: Unknown
Due 10 May 1985
Resolved 10 May 1985
Fire Fighting
Issued 10 May 1985 Resolved
INSTALL A FIXED POWER DRIVEN FIRE PUMP AND SYSTEMN (46CFR181.10,181.15)
Condition: Unknown
Due 10 May 1985
Resolved 10 May 1985
Lifesaving
Issued 10 May 1985 Resolved
INSTALL APPROVED FLOAT-FREE LINKS ON BOTH BOUYANT APPARATUS
Condition: Unknown
Due 10 May 1985
Resolved 10 May 1985
Electrical
Issued 10 May 1985 Resolved
REMOVE ALL DEAD END ELECTRICAL CABLES AND WIRES
Condition: Unknown
Due 10 May 1985
Resolved 10 May 1985
Electrical
Issued 10 May 1985 Resolved
INSTALL GUARDS ON LIGHT FIXTURES IN BOTH RESTROOMS
Condition: Unknown
Due 10 May 1985
Resolved 10 May 1985
Construction/Loadline
Issued 10 May 1985 Resolved
REMOVE ALL LOOSE ITEMS AND CLEAN BILGES FOR FURTHER INSPECTION
Condition: Unknown
Due 10 May 1985
Resolved 10 May 1985
Navigation
Issued 10 May 1985 Resolved
INSTALL CLASS 'C' EPIRB IN PILOTHOUSE
Condition: Unknown
Due 10 May 1985
Resolved 10 May 1985

Ownership record