MAURY USCG vessel records Sign in
← All vessels

HAPPY SNAPPER

HAPPY SNAPPER is a 1970 passenger vessel (uninspected). The Coast Guard has recorded 43 inspections since 1982, most recently in September 2015, along with 104 deficiencies — 4 with no resolution recorded —.

Records from 1982 to 2015. Most recent: inspection, 25 September 2015.

Built
1970
Last inspected
25 September 2015
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WYZ2161
Flag
UNITED STATES
—
Maury page id
psix-46639

Inspections, by type

…with no type recorded12
Years with a record 19 calendar years (1982–2015)
The 43 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 11 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it18 - Regulatory (Subpart C or D), Gross Ton
12 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WCG5790MMSI not assigned · expired · compulsorily equipped · granted 11 May 1998, cancelled 25 July 2004
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 43

25 September 2015 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5728594
12 March 2008 Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3160056
18 March 2004 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2062038
3 February 2004 Deficiency Check · Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1997884
28 January 2004 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2062016
9 January 2004 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2061997
6 January 2004 Hull Examination · Internal Structural Exam
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1941704
25 August 2003 Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1867090
12 July 2003 Type not recorded
No type recorded · Station Gulfport · USCG Heartland District (CGD-H) · Activity 1859699
22 October 2002 Type not recorded
No type recorded · Station Gulfport · USCG Heartland District (CGD-H) · Activity 1694703
19 September 2002 Administrative Inspection · Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1677102
19 July 2002 Type not recorded
No type recorded · Station Gulfport · USCG Heartland District (CGD-H) · Activity 1649140
5 July 2002 Annual Inspection · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1643336
29 May 2001 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1066227
12 June 2000 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1050948
12 May 2000 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 818601
17 April 2000 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1420296
2 December 1999 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 809809
2 December 1999 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 811993
24 August 1999 Type not recorded
No type recorded · Station Gulfport · USCG Heartland District (CGD-H) · Activity 1510707
5 May 1999 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1432171
29 January 1999 Plan Review "T" Boat
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1042887
29 January 1999 Plan Review "T" Boat
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1350696
30 June 1998 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1127112
12 May 1998 Hull Examination · Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1427528
13 May 1997 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1392693
14 May 1996 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1412983
22 February 1996 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1412982
24 July 1995 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1184116
20 March 1995 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1412757
17 January 1995 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1459927
25 July 1994 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1174541
20 May 1994 Plan Review "T" Boat · COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1016988
28 April 1994 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1014432
14 April 1994 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1022695
1 June 1987 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1013095
2 April 1987 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1328019
8 April 1986 Credit Drydock · Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 999252
13 March 1985 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 979944
27 March 1984 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 973056
18 February 1983 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 967233
8 March 1982 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1274328
24 February 1982 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1275661

Deficiency record · 104

Engineering › Diesel Engine (propulsion-reduction gear) › Valve
Issued 12 March 2008 No resolution recorded
Cap off unused valve in midbody compartment on the starboard side.
Action required: 705 - Other - as specified
Construction/Loadline › Hull › Hull Plating
Issued 12 March 2008 No resolution recorded
Repair deck in way of the bow inboard of the hatch leading to the forpeak.
Action required: 705 - Other - as specified
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 12 March 2008 No resolution recorded
Repair all deck rails and insure all rails are at least 30 inches high,
Action required: 705 - Other - as specified
Personnel › Certificates/Documents/Licenses › License, Radio Officer
Issued 18 March 2004 Resolved
Provide FCC Marine Radio operator's permit as required by 46 CFR 184.502 & 47 CFR 80.
Due 18 April 2004
Resolved 1 April 2004
Resolution: Master provded FCC Marine Raio Operator''''s Permit and found valid.
Documentation › Logs/Records › Drug Test Records
Issued 3 February 2004 Resolved
Provide evidence that crewmembers participate in an alcohol/drug audit program as required by 46 CFR 16.
Due 3 March 2004
Resolved 18 March 2004
Resolution: Drug cards provided to shore drug testing enrollment.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 3 February 2004 Resolved
Provide training log book that documents the names of the persons who attended, training conducted, and date the drill was conducted per 46 CFR 185.520.
Due 3 March 2004
Resolved 27 February 2004
Resolution: Log book provided.
Documentation › Logs/Records › Maneuvering Performance Test Results
Issued 3 February 2004 Resolved
Provide method to document that the EPIRB test is completed monthly per 46 CFR 185.728.
Due 3 March 2004
Resolved 27 February 2004
Resolution: Log book to record EPRIB test provided.
Navigation › Piloting/Steering › Magnetic Compass
Issued 3 February 2004 Resolved
Provide a light for the magnetic compass per 46 CFR 184.402(c).
Due 3 March 2004
Resolved 27 February 2004
Resolution: Light provided and tested with no problems noted.
Lifesaving › Lifefloat › Serviceable
Issued 3 February 2004 Resolved
Provide proper markings for lifefloat oer 46 CFR 1853604(d).
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 February 2004
Resolved 27 February 2004
Resolution: Marking verfied with no problems noted.
Lifesaving › Lifefloat › Serviceable
Issued 3 February 2004 Resolved
Provide proper length of line for the waterlight attached to the lifefloat per 46 CFR 180.175(f)(4).
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 February 2004
Resolved 27 February 2004
Resolution: Proper length of line provided on the lifefloat.
Lifesaving › Lifefloat › Serviceable
Issued 3 February 2004 Resolved
Secure paddles to the lifefloat ina break-free arrangement per 46 CFR 180.175(f)(2).
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 February 2004
Resolved 27 February 2004
Resolution: Paddles secured to the lifefloat.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 3 February 2004 Resolved
Provide proper mount for fire extinguisher per 46 CFR 181.500.
Due 3 March 2004
Resolved 27 February 2004
Resolution: Fire extiguisher mounted in the proper bracket.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 3 February 2004 Resolved
Replace expired medications in the first aid box per 46 CFR 184.710.
Due 3 March 2004
Resolved 27 February 2004
Resolution: Medicine replaced in the first aid box.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 3 February 2004 Resolved
Remark first aid kit such that it is easily identifiable per 46 CFR 184.710.
Due 3 March 2004
Resolved 27 February 2004
Resolution: First aid kit re-labeled.
Electrical › Electrical Distribution System (service) › Wiring
Issued 3 February 2004 Resolved
Replaced chaffed wire on the aft bulkhead of the accommodations space per 46 CFR 183.340(c).
Due 3 March 2004
Resolved 27 February 2004
Resolution: Wire replaced and found satisfactory.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 3 February 2004 Resolved
Provide proper stowage of gear in the forward compartment to prevent "missle" hazards.
Due 3 March 2004
Resolved 27 February 2004
Resolution: All extraneous gear was removed from the vessel.
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 3 February 2004 Resolved
Remove all flammable paints/oil stowed in the forward compartment.
Due 3 March 2004
Resolved 27 February 2004
Resolution: All flammable material stowed in the forward compartment removed.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 3 February 2004 Resolved
Demonstrate proper operation of the override system for fixed fire fighting extinguishing systems for the engines per 46 CFR 181.420.
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 February 2004
Resolved 27 February 2004
Resolution: Conducted operational test of the override system with no problems noted.
Engineering › Bilge Water Management System › Pump
Issued 3 February 2004 Resolved
Provide visual indicators at the operating station to indicate when the automatic bilge pump is operating pe 46 CFR 182.530(c).
Due 3 February 2004
Resolved 27 February 2004
Resolution: Visual inidcator provided and operationally tested.
Engineering › Shafting/Propeller Arrangements
Issued 6 January 2004 Resolved
Replace worn cutless bearings for port/starboard shafts. LEGACY COMPONENT DESC: Bearing
Due 4 February 2004
Resolved 3 February 2004
Resolution: Cutless bearings replaced.
Engineering › Shafting/Propeller Arrangements
Issued 6 January 2004 Resolved
Replace port and starboard stuffing tubes. LEGACY COMPONENT DESC: Stern Tube
Due 6 February 2004
Resolved 3 February 2004
Resolution: Port and starboard stuffing tubes replaced.
Deck/Cargo
Issued 6 January 2004 Resolved
Replace all eroded zincs. LEGACY COMPONENT DESC: zincs
Due 6 February 2004
Resolved 28 January 2004
Resolution: Zincs replaced and secured correctly.
Deck/Cargo
Issued 6 January 2004 Resolved
Provide proposal for fiberglass repair on damaged port transom. LEGACY COMPONENT DESC: Hull repair
Due 6 February 2004
Resolved 9 January 2004
Resolution: Received proposal and repairs were made in accordance with NVIC 8-87, Notes of Design, Construction, Inspection and Repair of FRP Vessels.
Accommodation/Occupational Safety › Occupational Safety
Issued 6 January 2004 Resolved
Replace rotted floor in main salon. LEGACY COMPONENT DESC: Deck
Due 6 February 2004
Resolved 18 March 2004
Resolution: Floor replaced in main salon.
Engineering
Issued 6 January 2004 Resolved
Make all bilges free of water and debris for visual examination. LEGACY COMPONENT DESC: Bilge
Due 6 February 2004
Resolved 3 February 2004
Resolution: Bilges free of water and debris; found areas satisfactory.
Construction/Loadline › Hull
Issued 6 January 2004 Resolved
Replace rotted butt block starboard side in way of head. LEGACY COMPONENT DESC: Butt Block
Due 6 February 2004
Resolved 3 February 2004
Resolution: Butt block replaced starboard side in way of head.
Construction/Loadline › Hull
Issued 6 January 2004 Resolved
Provide repair proposal to repair cracked frame in way of refrigerator. LEGACY COMPONENT DESC: Frame
Due 6 February 2004
Resolved 6 January 2004
Resolution: Requirement written in error.
Navigation › Piloting/Steering
Issued 6 January 2004 Resolved
Remove anchor line from forepeak. LEGACY COMPONENT DESC: anchor Line
Due 6 February 2004
Resolved 6 January 2004
Resolution: The anchor line was removed and the are below was open for inspection.
Construction/Loadline
Issued 6 January 2004 Resolved
Renew corroded fasteners portside, frame forward of collision bulkhead. LEGACY COMPONENT DESC: Fastners
Due 6 February 2004
Resolved 28 January 2004
Resolution: Fasteners renewed and frame refastened.
Engineering
Issued 6 January 2004 Resolved
Double clamp hose for bilge pump aft of engine room. LEGACY COMPONENT DESC: bilge pump
Due 6 February 2004
Resolved 3 February 2004
Resolution: Found hose for bilge pump aft in engine room double clamped.
Engineering
Issued 6 January 2004 Resolved
Replace broken handle for overboard valve to head located port side. LEGACY COMPONENT DESC: overboard for head
Due 6 February 2004
Resolved 3 February 2004
Resolution: Handle renewed for valve for head.
Construction/Loadline › Hull
Issued 6 January 2004 Resolved
Replace broken fasteners in floor frames in steering compartment. LEGACY COMPONENT DESC: Longitudinal Frame
Due 6 February 2004
Resolved 28 January 2004
Resolution: Replaced fasteners in floor frames.
Construction/Loadline
Issued 6 January 2004 Resolved
Replace broken ceiling panel locatd starboard side, forward bulkhead of engine room. LEGACY COMPONENT DESC: ceiling panel
Due 6 February 2004
Resolved 3 February 2004
Resolution: Ceiling panel replaced.
Navigation › Piloting/Steering
Issued 6 January 2004 Resolved
Tighten loose jockey bar. LEGACY COMPONENT DESC: Jockey Bar
Due 6 February 2004
Resolved 28 January 2004
Resolution: Jockey bar tightened and steering tested satisfactory.
Construction/Loadline › Hull › Side Shell
Issued 6 January 2004 Resolved
Provide repair proposal for 3 cracked areas on bow as marked.
Due 6 February 2004
Resolved 6 January 2004
Resolution: Owner/Operator provided repair proposal.
Lifesaving › Lifejacket/PFD (General)
Issued 25 August 2003 Resolved
Replace six rotted adult lifejackets as required by 46CFR180.25.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 August 2003
Resolution: Lifejackets replaced with six new ones.
Lifesaving › Lifejacket/PFD (General)
Issued 25 August 2003 Resolved
Provide six additional lifejackets to meet the required 30 adult lifejackets as identified on the vessel's COI as required by 46CFR 180.71. (These jackets are not the same jackets as item #1).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 August 2003
Resolution: Provided six additional lifejackets for the required total of 30 persons on board.
Lifesaving › Hand Flares
Issued 25 August 2003 Resolved
Provide three additional orange flares as required by 46 CFR 185.68.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 August 2003
Resolution: Provided three orange flares for a total of six.
Lifesaving
Issued 25 August 2003 Resolved
Repair or replace lifefloat as required by 46CFR 185.700.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 August 2003
Resolution: Replaced lifefloat and provided weak-link with 300 feet of lifeline.
Communications › Radio Communications
Issued 25 August 2003 Resolved
Provide proof of EPIRB battery expiration date as required by 46CFR 185.728. LEGACY COMPONENT DESC: EPIRB
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 August 2003
Resolution: Provided battery expiration document and proof of NOAA registration.
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 25 August 2003 Resolved
Replace broken bracket for fire extinguisher located starboard side of bridge as required by 46 CFR 181.520.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 August 2003
Resolution: Provided new bracket specific to fire extinguisher.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 25 August 2003 Resolved
Repair exhaust leak on port exhaust in lazarette as required by 46 CFR 182.20-20. This wooden vessel has wet exhaust. Water was leaking into the lazerette. The vessel did not have a high bilge alarm in the lazerrette.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 August 2003
Resolution: Repaired leak on port exhaust.
Lifesaving › Lifebuoys
Issued 25 August 2003 Resolved
Provide and splice clip for ring buoy.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 August 2003
Resolution: Provided clip and splice on lanyard for light for ring buoy.
Electrical
Issued 25 August 2003 Resolved
Plug receptacle box in way of fireboy bottle. (The access plug was missing)
Due 25 September 2003
Resolved 28 August 2003
Resolution: Plugged receptable outlet.
Operations/Management › FireFighting
Issued 25 August 2003 Resolved
Conduct fire and man overboard drills with entire crew as required by 46 CFR 185.520 and 185.524.
Due 25 September 2003
Resolved 28 August 2003
Resolution: Satisfactorily conducted fire and man overboard drills.
Stability
Issued 25 August 2003 Resolved
Provide portable (hand) bilge pump as required by 46 CFR 182.25.
Due 25 September 2003
Resolved 28 August 2003
Resolution: Provide hand bilge pump with proper length of hose.
Engineering
Issued 25 August 2003 Resolved
Provide/install bilge high level alarms as required by 46CFR 182.530.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 August 2003
Resolution: Installed high level bilge alarms on vessel''s bridge console.
Communications › Radio Communications
Issued 25 August 2003 Resolved
Prove VHF radio transmits as required by 46CFR 184.502. LEGACY COMPONENT DESC: VHF Radiotelephone
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 August 2003
Resolution: Received radio response from local marina.
Pollution Prevention/Response
Issued 25 August 2003 Resolved
Make engine room bilges clean and dry of oil.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 August 2003
Resolution: Engine room bilges were clean and dry for satisfactory inspection.
Lifesaving › Lifejacket/PFD (General)
Issued 25 August 2003 Resolved
Replace deteriorated retro-reflective tape on 8 adult life jackets as required by 46CFR 185.604(h).
Due 25 September 2003
Resolved 28 August 2003
Resolution: Replaced retro-reflective tape on eight lifejackets.
Operations/Management › Vessel Safety Management
Issued 25 August 2003 Resolved
Provide log book for crew training lifesaving and fire fighting equipment inspections and steering tests. 46 CFR 185.420; 185.702;185.524.
Due 25 September 2003
Resolved 28 August 2003
Resolution: Added crew training section, lifesaving and firefighting check sheet and steering tests to vessel logbook.
Navigation › Piloting/Steering
Issued 25 August 2003 Resolved
Provide nautical publications as required by 46 CFR 184.420. LEGACY COMPONENT DESC: Notices to Navigation
Due 25 September 2003
Resolved 28 August 2003
Resolution: Provided 2003 nautical publications.
Accommodation/Occupational Safety › Occupational Safety
Issued 25 August 2003 Resolved
Repair/Replace hand rail cables as required by 46CFR 177.900.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 August 2003
Resolution: Repaired cable hand rails on starboard side of vessel using a plastic sheath.
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 25 August 2003 Resolved
Remove all roaches and other pests from vessel.
Due 25 September 2003
Resolved 28 August 2003
Resolution: Vessel sprayed and all pests removed.
Fire Fighting
Issued 25 August 2003 No resolution recorded
Provide 3 2.5 gallon fire buckets as required by 46CFR 181.
Action required: 701 - Prior to carriage of passengers/cargo
Resolution: Three fire buckets provided on board vessel.
Engineering › Sea-water System (primary cooling)
Issued 5 July 2002 Resolved
Cooling line on port main diesel engine leaks. LEGACY COMPONENT DESC: Piping
Due 5 July 2002
Resolved 5 July 2002
Personnel › Manning/Qualifications
Issued 3 July 2002 Resolved
Provide proof of drug testing. LEGACY COMPONENT DESC: Medical Fitness
Condition: Unknown
Due 5 September 2002
Resolved 19 September 2002
Resolution: Proof of drug testing was verified.
Navigation › Piloting/Steering
Issued 3 July 2002 Resolved
Provide Tide Tables, Current Tables, Light List, Coast Pilot LEGACY COMPONENT DESC: Coast Guard Light List
Action required: 705 - Other - as specified
Due 3 August 2002
Resolved 5 July 2002
Resolution: Provided material.
Navigation › Collision/Grounding Avoidance
Issued 3 July 2002 Resolved
Prove operation of Radar. LEGACY COMPONENT DESC: Radar
Condition: Unknown
Action required: 705 - Other - as specified
Due 5 August 2002
Resolved 5 July 2002
Lifesaving › Embarkation Appliances/Stations
Issued 3 July 2002 Resolved
Provide repair proposal for rail stanchion at port and starboard embarkation areas. LEGACY COMPONENT DESC: Handholds
Condition: Unknown
Action required: 705 - Other - as specified
Due 5 September 2002
Resolved 19 September 2002
Resolution: Repair proposal was presented and proper repairs were made. Stantions were reinforced with larger tubing.
Lifesaving › Liferaft Equipment
Issued 3 July 2002 Resolved
Provide 4 Ft. paddle for Life Float. LEGACY COMPONENT DESC: Paddle
Condition: Unknown
Action required: 705 - Other - as specified
Due 3 August 2002
Resolved 5 July 2002
Lifesaving › Lifejacket/PFD (General)
Issued 3 July 2002 Resolved
Replace Retro on 3 Life Jackets. LEGACY COMPONENT DESC: Retroreflective Material
Condition: Unknown
Due 3 August 2002
Resolved 5 July 2002
Fire Fighting › Fire Pumps
Issued 3 July 2002 Resolved
Provide 2 more Fire Buckets. LEGACY COMPONENT DESC: Arrangement
Condition: Unknown
Action required: 705 - Other - as specified
Due 3 August 2002
Resolved 5 July 2002
Accommodation/Occupational Safety › Cooking Systems
Issued 3 July 2002 Resolved
Remove LPG line. LEGACY COMPONENT DESC: LPG System Requirements
Condition: Unknown
Due 3 August 2002
Resolved 5 July 2002
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 3 June 2002 Resolved
Provide proper support for all hoses and cables in engine room. LEGACY COMPONENT DESC: Piping (air intake)
Condition: Unknown
Due 3 August 2002
Resolved 3 July 2002
Construction/Loadline › Penetrations
Issued 3 June 2002 Resolved
Provide repairs to crack located forward of starboard side strut in accordance with 8-87 FRP NVIC 7-87. LEGACY COMPONENT DESC: Weld
Condition: Unknown
Due 5 August 2002
Resolved 5 July 2002
Engineering › Lubricating Oil Storage/Transfer System
Issued 3 June 2002 Resolved
Replace hose on port MDE exhaust with CG approved hose as required by 46 CFR 182.720 , vital system requirements. LEGACY COMPONENT DESC: Hose
Condition: Unknown
Action required: 705 - Other - as specified
Due 5 August 2002
Resolved 5 July 2002
Engineering › Bilge Water Management System
Issued 3 June 2002 Resolved
Provide proper hoses for submersable pump installation with double clamps. LEGACY COMPONENT DESC: Piping
Condition: Unknown
Action required: 705 - Other - as specified
Due 5 August 2002
Resolved 5 July 2002
Engineering › Fuel Oil Storage/Transfer System
Issued 3 June 2002 Resolved
Repair mechanical fuel shut off valve. LEGACY COMPONENT DESC: Valve
Condition: Unknown
Action required: 705 - Other - as specified
Due 5 August 2002
Resolved 5 July 2002
Electrical › Lighting (service)
Issued 3 June 2002 Resolved
Provide proper wiring for engine room cable ways using Junction boxes and cable clamps. 46 CFR 83.340 & 46 cfr 183-10-20. LEGACY COMPONENT DESC: Lighting Feeder
Condition: Unknown
Action required: 705 - Other - as specified
Due 5 August 2002
Resolved 5 July 2002
Lifesaving › Lifejacket/PFD (Type IV)
Issued 3 June 2002 Resolved
Replace Ring Bouy. LEGACY COMPONENT DESC: Condition
Condition: Unknown
Action required: 705 - Other - as specified
Due 5 August 2002
Resolved 5 July 2002
Engineering › Lubricating Oil Storage/Transfer System
Issued 3 June 2002 Resolved
Replace lube oil lines on starboard engine. LEGACY COMPONENT DESC: Piping
Condition: Unknown
Action required: 705 - Other - as specified
Due 5 August 2002
Resolved 5 July 2002
Construction/Loadline › Structures
Issued 3 June 2002 Resolved
Provide supports for both desil engine exhausts. LEGACY COMPONENT DESC: Superstructure
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Due 5 August 2002
Resolved 5 July 2002
Electrical › Electrical Distribution System (service)
Issued 16 May 2002 Resolved
Remove dead end wiring from uinder cabin deck and cabin area. LEGACY COMPONENT DESC: Wiring
Condition: Unknown
Due 3 August 2002
Resolved 5 July 2002
Electrical › Electrical Distribution System (service)
Issued 16 May 2002 Resolved
Trace forward bilge line, Ensure bilge capability in compartment. LEGACY COMPONENT DESC: Wiring
Condition: Unknown
Action required: 705 - Other - as specified
Due 5 August 2002
Resolved 5 July 2002
Accommodation/Occupational Safety › Occupational Safety
Issued 16 May 2002 Resolved
Replace aft stantion deck rails. LEGACY COMPONENT DESC: Deck Rail
Condition: Unknown
Due 5 August 2002
Resolved 5 July 2002
Accommodation/Occupational Safety › Cooking Systems
Issued 16 May 2002 Resolved
Remove LPG bottle. LEGACY COMPONENT DESC: LPG System Requirements
Due 5 August 2002
Resolved 5 July 2002
Operations/Management › Pollution
Issued 9 May 2002 Resolved
Clean oil and debris from engine room and make ready for inspection. LEGACY COMPONENT DESC: Removal Methods/Procedures
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 August 2002
Resolved 5 July 2002
Construction/Loadline › Hull
Issued 9 May 2002 Resolved
Repair chips in stem. LEGACY COMPONENT DESC: Hull Plating
Condition: Unknown
Action required: 705 - Other - as specified
Due 3 August 2002
Resolved 5 July 2002
Engineering › Sea-water System (primary cooling)
Issued 9 May 2002 Resolved
Replace seawater hose on #1Diesel engine. (starboard) LEGACY COMPONENT DESC: Piping
Condition: Unknown
Action required: 705 - Other - as specified
Due 3 August 2002
Resolved 5 July 2002
Engineering › Sea-water System (primary cooling)
Issued 9 May 2002 Resolved
Remove cover/shelf over sea strainers and make ready for Inspection. LEGACY COMPONENT DESC: Valve
Condition: Unknown
Action required: 705 - Other - as specified
Due 3 August 2002
Resolved 5 July 2002
Engineering › Bilge Water Management System
Issued 9 May 2002 Resolved
Provide double clamps on all bilge systems. LEGACY COMPONENT DESC: Hose
Condition: Unknown
Action required: 705 - Other - as specified
Due 3 August 2002
Resolved 5 July 2002
Electrical › Electric Generation Source (service)
Issued 9 May 2002 Resolved
Rewire battery charger with approved cable. LEGACY COMPONENT DESC: Generator
Condition: Unknown
Action required: 705 - Other - as specified
Due 3 August 2002
Resolved 3 June 2002
Electrical › Electric Supply System (service)
Issued 9 May 2002 Resolved
Replace battery charger with appproved marine charger or remove system. LEGACY COMPONENT DESC: Battery Charger
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 August 2002
Resolved 3 June 2002
Engineering › Bilge Water Management System
Issued 9 May 2002 Resolved
repair or remove dupe bilge system. LEGACY COMPONENT DESC: Pump
Condition: Unknown
Action required: 705 - Other - as specified
Due 3 August 2002
Resolved 3 June 2002
Pollution Prevention/Response › Prevention Equipment
Issued 9 May 2002 Resolved
Repair or remove oil recovery system. LEGACY COMPONENT DESC: Means of Removal from within Coaming
Condition: Unknown
Action required: 705 - Other - as specified
Due 3 August 2002
Resolved 3 June 2002
Engineering › Fuel Oil Service System
Issued 9 May 2002 Resolved
Repair oil sending unit LEGACY COMPONENT DESC: Piping
Condition: Unknown
Due 3 August 2002
Resolved 5 July 2002
Accommodation/Occupational Safety › Washroom/Toilet
Issued 9 May 2002 Resolved
Repair MSD holding tank. LEGACY COMPONENT DESC: Toilet
Condition: Unknown
Action required: 705 - Other - as specified
Due 3 August 2002
Resolved 5 July 2002
Construction/Loadline › Hull
Issued 9 May 2002 Resolved
Provide repair proposal for rotted frames on starboard side in engine room. LEGACY COMPONENT DESC: Longitudinal Frame
Condition: Unknown
Due 3 August 2002
Resolved 5 July 2002
Construction/Loadline › Hull
Issued 9 May 2002 Resolved
Provide repair proposal for transverse bottom frame at chin one foot from transom. LEGACY COMPONENT DESC: Transverse Frame
Condition: Unknown
Due 3 August 2002
Resolved 5 July 2002
Engineering › Fuel Oil Storage/Transfer System
Issued 9 May 2002 Resolved
Repair fuel oil leak in return line starboard side aft of fuel tank at connection. LEGACY COMPONENT DESC: Piping
Condition: Unknown
Action required: 705 - Other - as specified
Due 3 August 2002
Resolved 5 July 2002
Engineering › Shafting/Propeller Arrangements
Issued 9 May 2002 Resolved
Pull shafts, make cutlass bearing ready for inspection. LEGACY COMPONENT DESC: Propeller Shaft
Condition: Unknown
Action required: 705 - Other - as specified
Due 3 August 2002
Resolved 5 July 2002
Engineering
Issued 12 May 2000 Resolved
PROPERLY MARK FUEL OIL SHUT OFF VALVES AS REQUIRED BY 46 CFR 185.608
Condition: Unknown
Due 12 May 2000
Resolved 12 May 2000
Lifesaving
Issued 12 May 2000 Resolved
PROVIDE 5 ADULT LIFE JACKETS, PASSENGERS ALLOWED IS REDUCED TO 25 UNTIL COMPLETED. 46 CFR 180.70 (a).
Condition: Unknown
Due 12 May 2000
Resolved 12 May 2000
Construction/Loadline
Issued 5 May 1999 Resolved
THE PORTABLE HAND BILGE PUMP SHALL BE PROVIDED WITH SUITABLE HOSES FOR PUMPING BILGES ON THE SUCTION AND DISCHARGE ENDS IN ACCORDANCE WITH 46 CFR 182.25-10(e) TO THE SATISFACTION OF THE ATTENDING U.S. COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 5 May 1999
Resolved 5 May 1999
Construction/Loadline
Issued 5 May 1999 Resolved
REPAIR OR RENEW FORWARD WATERTIGHT HATCH. HATCH IS TO BE PROVEN WATERTIGHT TO THE SATISFACTION OF THE ATTENDING U.S. COAST GUARD MARINE INSPECTOR. SEE46 CFR 176.25-5 AND 46 CFR 171.124._x001C_
Condition: Unknown
Due 5 May 1999
Resolved 5 May 1999
Construction/Loadline
Issued 5 May 1999 Resolved
PERMANENTLY ATTACH ALUMINUM AWNING FRAMING TO DECK TO THE SATISFACTION OF THE ATTENDING U.S. COAST GUARD MARINE INSPECTOR. SEE 46 CFR 176.25-5.
Condition: Unknown
Due 5 May 1999
Resolved 5 May 1999
Engineering
Issued 5 May 1999 Resolved
DETERMINE CAUSE OF VIBRATION FROM PORT SHAFT AND REPAIR DEFECTS NOTED TO THE SATIFACTION OF THE ATTENDING U.S. COAST GUARD MARINE INSPECTOR. SEE 46 CFR 176.25-1
Condition: Unknown
Due 5 May 1999
Resolved 5 May 1999
Engineering
Issued 5 May 1999 Resolved
IDENTIFY AND REPAIR ALL SALT WATER COOLING LEAKS ON MAIN ENGINES TO THE SATISFACTION OF THE ATTENDING U.S. COAST GUARD MARINE INSPECTOR. SEE 46 CFR176.25-10.
Condition: Unknown
Due 5 May 1999
Resolved 5 May 1999
Electrical
Issued 5 May 1999 Resolved
INSTALL ELECTRICAL RECEPTACLE COVER PLATE TO OTLET LOCATED IN THE WHEELHOUSE TO THE SATISFACTION OF THE ATTENDING U.S. COAST GUARD MARINE _x001C_ INSPECTOR. SEE 46 CFR 176.25-50(a).
Condition: Unknown
Due 5 May 1999
Resolved 5 May 1999
Documentation
Issued 12 May 1998 Resolved
PROVIDE ON BOARD A VALID CERTIFICATE OF DOCUMENTATION.
Condition: Unknown
Due 9 July 1998
Resolved 30 June 1998
Documentation
Issued 20 May 1994 Resolved
PROVIDE OPERATORS LICENSE FOR #2 AND #3. TO BE TO THE SATISFACTION OF AN ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 20 May 1994
Resolved 20 May 1994
Documentation
Issued 20 May 1994 Resolved
PROVIDE FCC STATION LICENSE. TO BE TO THE SATISFACTION OF AN ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 20 May 1994
Resolved 20 May 1994
Documentation
Issued 20 May 1994 Resolved
PROVIDE FCC SAFETY CERTIFICATE. TO BE TO THE SATISFACTION OF AN ATTENDING MARINE INSPECTOR._x001C_
Condition: Unknown
Due 20 May 1994
Resolved 20 May 1994

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.