This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Registered dimensions (L × B × D)60.0 ft × 21.0 ft × 5.0 ft
Registered tonnagegross 54 / net 54
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDUBUQUE BOAT & BOILER CO · DUBUQUE IA, UNITED STATES · built 1970
Hull materialSteel
PropulsionDiesel
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portTUSCALOOSA, AL
Endorsements, as the file codes themcw_un
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Uninspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it54 - Regulatory (Subpart C or D), Gross Ton 54 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel
Behind this panel: 7 inspections, each with its date, unit and type; 11 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1972 to
2026, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 7
15 June 2021Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7226119
17 January 2020Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6891742
29 January 2019Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6616756
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 26 February 2019Resolved
Provide appropriate number of distress signals IAW 46 CFR 180.68
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 12 March 2019
Resolved 28 February 2019
Resolution: Owner provided photographs of newly purchased distress signals
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 26 February 2019Resolved
Replace retroflective tape on 01 child size life jackets. Ensure vessel does not operate with more children than lifejackets.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 March 2019
Resolved 28 February 2019
Resolution: Owner provided photograph of renewed retroflective tape
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 26 February 2019Resolved
Ensure drills are conducted every three months.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 March 2019
Resolved 28 February 2019
Resolution: Owner provided evidence of accurate drill logs
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 26 February 2019Resolved
Ensure all items in the first aid kt are in date
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 March 2019
Resolved 28 February 2019
Resolution: Owner provided photographs of replacement first aid items
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 26 February 2019Resolved
Ensure all navigation documents on board are up to date.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 March 2019
Resolved 28 February 2019
Resolution: Owner provided evidence that updated light list was downloaded and available on board.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 26 February 2019Resolved
Operator is required to possess a General Marine Radio Operator Permit. Obtain the Marine Radio Operator Permit in lieu of the restricted permit.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 March 2019
Resolved 10 March 2020
Construction/Loadline › Structures › Manhole
Issued 20 February 2018Resolved
Water tight hatch was missing hardware, 46CFR179.330
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 February 2018
Resolved 22 February 2018
Resolution: Hardwware added and tested.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 February 2018
Resolved 22 February 2018
Resolution: Name was stenciled on and looked good.
Nav light, stern light was not working, 46CFR183.420
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 February 2018
Resolved 22 February 2018
Resolution: Stern light repaired and working.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 29 November 2016Resolved
EAP for supervisors has not been completed.
Condition: Invalid
Action required: 705 - Other - as specified
Due 16 December 2016
Resolved 15 February 2017
Resolution: Provided evidence of completion of required EAP training.
AIS was not installed as required by OCMI. A class B AIS will need to be installed and verified by an FCC rep. Vessel limited to only opeate in Oliver pool until an AIS is properly installed.
Condition: Invalid
Action required: 705 - Other - as specified
Due 16 December 2016
Resolved 15 February 2017
Resolution: Provided evidence of installed Class B AIS.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.