MAURY USCG vessel records Sign in
← All vessels

LEATHERNECK

LEATHERNECK is a 1970 passenger vessel (inspected). The Coast Guard has recorded 46 inspections since 1985, most recently in January 2001, along with 98 deficiencies.

Records from 1985 to 2001. Most recent: inspection, 21 January 2001.

Built
1970
Last inspected
21 January 2001
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDE3054
Flag
UNITED STATES
367333450
Maury page id
psix-46650

Inspections, by type

…with no type recorded12
Years with a record 16 calendar years (1985–2001)
The 46 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 25 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it48 - Regulatory (Subpart C or D), Gross Ton
33 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDE3054MMSI 367333450 · active · compulsorily equipped · granted 12 January 2018, expires 25 January 2028
WTR4814MMSI not assigned · expired · compulsorily equipped · granted 24 September 1997, cancelled 9 February 2008
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

PANAMAX RIDE Freight Ship · MISLE 380501 · 16 September 1994 · activity 73945

Inspection history · 46

21 January 2001 Administrative
Administrative · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1064674
18 January 2001 Administrative
Administrative · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1399520
28 July 2000 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1361631
26 August 1999 Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1115835
21 August 1999 Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1114567
29 July 1999 COI Inspection · MARPOL Annex V Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1361028
8 June 1999 Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 805934
9 May 1999 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 796495
5 October 1998 Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 801241
8 September 1998 Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 798591
28 July 1998 Re-Inspection · Hull Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1372247
3 September 1997 Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1119952
17 July 1997 Re-Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1390566
21 October 1996 Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1159189
2 August 1996 COI Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1251460
21 July 1996 Administrative
Administrative · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1092806
12 June 1996 Hull Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1087134
29 February 1996 Administrative
Administrative · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1080952
22 February 1996 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 132194
28 April 1995 Re-Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1371075
14 December 1994 Administrative
Administrative · MSO GUAM · USCG Oceania District (CGD-O) · Activity 835903
16 September 1994 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 73945
8 April 1994 COI Inspection · Hull Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1170573
10 February 1994 Administrative
Administrative · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1163744
25 March 1993 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1148036
25 March 1993 Administrative
Administrative · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1148037
1 December 1992 Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 832746
26 October 1992 Administrative
Administrative · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1261864
8 October 1992 COI Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1260191
11 November 1991 Re-Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 941106
14 March 1991 Hull Examination · Re-Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 911808
13 October 1989 COI Inspection · Hull Examination · Examination of Repairs
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 932134
1 September 1988 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1198587
1 September 1988 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1351312
14 July 1988 COI Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1032771
8 April 1988 Hull Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 887478
17 July 1987 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1007606
24 June 1987 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1007911
8 June 1987 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1029193
29 January 1987 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1326058
17 January 1987 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1008477
26 November 1986 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1314943
20 November 1986 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1331443
17 October 1986 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1016999
16 September 1986 Credit Drydock · Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1006044
16 July 1985 Deficiency Check · COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 980222

Deficiency record · 98

Engineering
Issued 29 July 1999 Resolved
Prove operation of the starboard engine tachometer.
Condition: Unknown
Due 29 July 1999
Resolved 29 July 1999
Fire Fighting
Issued 29 July 1999 Resolved
Provide proper marine type mounts for the two portable fire extinguishers located in the lower forward cabin space and for the B-I portable extinguisher at the operating station.
Condition: Unknown
Due 29 July 1999
Resolved 29 July 1999
Engineering
Issued 29 July 1999 Resolved
Free up fuel tank vent closure, starboard side aft, main deck aft.
Condition: Unknown
Due 29 July 1999
Resolved 29 July 1999
Engineering
Issued 29 July 1999 Resolved
Mark remote fuel oil shut-off location and direction of operation.
Condition: Unknown
Due 29 July 1999
Resolved 29 July 1999
Accommodation/Occupational Safety
Issued 29 July 1999 Resolved
Install additional chains across the bow passenger access points and the bow proper, for a total of three courses of chain at each point.
Condition: Unknown
Due 29 July 1999
Resolved 29 July 1999
Lifesaving
Issued 29 July 1999 Resolved
Replace expired EPIRB battery. Vessel is restricted to not more than 3 miles from shore until such time battery is replaced.
Condition: Unknown
Due 29 July 1999
Resolved 29 July 1999
Lifesaving
Issued 29 July 1999 Resolved
Remove all excess papers, bags, etc., which constitute a fire hazard from the lower forward cabin areas.
Condition: Unknown
Due 29 July 1999
Resolved 29 July 1999
Lifesaving
Issued 29 July 1999 Resolved
Conduct and log monthly, quarterly, semi-annual, and annual fire safety, lifesaving safety, and maintenance checks as provided in example in the back of the vessel log. Additionally, all required quarterly fire and man overboard drills shall also be logged as shown in the example.
Condition: Unknown
Due 29 July 1999
Resolved 29 July 1999
Construction/Loadline
Issued 29 July 1999 Resolved
Remove excess oil from the engineroom bilge.
Condition: Unknown
Due 29 July 1999
Resolved 29 July 1999
Engineering
Issued 29 July 1999 Resolved
Reattach the starboard engine, inboard air intake.
Condition: Unknown
Due 29 July 1999
Resolved 29 July 1999
Engineering
Issued 29 July 1999 Resolved
Install lagging over the exhaust section of the turbochargers on the main engines.
Condition: Unknown
Due 29 July 1999
Resolved 29 July 1999
Construction/Loadline
Issued 9 May 1999 Resolved
Provide proof of installation of bilge hi-level alarm & indicators meeting 46 CFR 182.530 for each space with a through hull fitting, machinery space,or space with a non-watertight hatch. Vessel COI will be revoked & vessel limited to nmt 6 passengers without proof of installation by 10JUN99.
Condition: Unknown
Due 9 May 1999
Resolved 9 May 1999
Unknown
Issued 28 July 1998 Resolved
Provide evidence of a proper drug testing program as per 46 CFR part 16
Condition: Unknown
Due 28 July 1998
Resolved 28 July 1998
Accommodation/Occupational Safety
Issued 28 July 1998 Resolved
Remove/replace linolium as it is a tripping hazard in its current condition.
Condition: Unknown
Due 28 July 1998
Resolved 28 July 1998
Accommodation/Occupational Safety
Issued 28 July 1998 Resolved
Repair flooring in fwd stateroom as it is a tripping hazard in its current condition.
Condition: Unknown
Due 28 July 1998
Resolved 28 July 1998
Lifesaving
Issued 28 July 1998 Resolved
Conduct and log man overboard and firefighting drills.
Condition: Unknown
Due 28 July 1998
Resolved 28 July 1998
Lifesaving
Issued 28 July 1998 Resolved
Conduct and log monthly EPIRB test.
Condition: Unknown
Due 28 July 1998
Resolved 28 July 1998
Fire Fighting
Issued 28 July 1998 Resolved
Place on board (3) three 2 1/2 gallon fire buckets with proper amount of line and properly marked.
Condition: Unknown
Due 28 July 1998
Resolved 28 July 1998
Lifesaving
Issued 28 July 1998 Resolved
Provide public address system.
Condition: Unknown
Due 28 July 1998
Resolved 28 July 1998
Electrical
Issued 28 July 1998 Resolved
Properly mark switchboard/circuits as per 46 CFR 183.220
Condition: Unknown
Due 28 July 1998
Resolved 28 July 1998
Electrical
Issued 28 July 1998 Resolved
Replace bulbs in lighting fixtures & emergency fixtures that are burnt out.Prove proper operation of emergency lighting.
Condition: Unknown
Due 28 July 1998
Resolved 28 July 1998
Construction/Loadline
Issued 28 July 1998 Resolved
Place onboard a portable bilge pump.
Condition: Unknown
Due 28 July 1998
Resolved 28 July 1998
Accommodation/Occupational Safety
Issued 28 July 1998 Resolved
Renew using good marine practice with like grade plate & scantling holed areas of deck house._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 28 July 1998
Resolved 28 July 1998
Navigation
Issued 28 July 1998 Resolved
place onboard vsl updated navigation charts, tide tables, light lists for area to be operated.
Condition: Unknown
Due 28 July 1998
Resolved 28 July 1998
Lifesaving
Issued 28 July 1998 Resolved
Repair/replace Life Float; drop net, retroreflective tape, markings, gouges.
Condition: Unknown
Due 28 July 1998
Resolved 28 July 1998
Lifesaving
Issued 28 July 1998 Resolved
Provide retroreflective tape for all (3) life rings buoys.
Condition: Unknown
Due 28 July 1998
Resolved 28 July 1998
Lifesaving
Issued 28 July 1998 Resolved
Prior to departing on a voyage, master shall provide a pasenger count to shore location and shall be available to Coast Guard Inspector upon requestas per 46 CFR 185.504.
Condition: Unknown
Due 28 July 1998
Resolved 28 July 1998
Lifesaving
Issued 28 July 1998 Resolved
Master shall ensure that suitable public announcement covering the 'Passenger Safety Orientation' listed in 46 CFR 185.506 is given before getting underway or as soon as practical thereafter.
Condition: Unknown
Due 28 July 1998
Resolved 28 July 1998
Fire Fighting
Issued 17 July 1997 Resolved
Vessel has spare fire extinguishers onboard that require servicing. Removethese spare extinguishers or service them in accordance with approved_x001C_ industry practices if the extinguishers are to remain on the vessel.
Condition: Unknown
Due 17 July 1997
Resolved 17 July 1997
Fire Fighting
Issued 17 July 1997 Resolved
Mount the additional B-II extinguisher for the engine room inside the main cabin along the aft bulkhead. Post a legible placard on the exterior of the main cabin stating "Engine Room Fire Extinguisher Located Inside."
Condition: Unknown
Due 17 July 1997
Resolved 17 July 1997
Navigation
Issued 17 July 1997 Resolved
Prove the proper operation of the magnetic compass light to the satisfaction of the local OCMI.
Condition: Unknown
Due 17 July 1997
Resolved 17 July 1997
Lifesaving
Issued 17 July 1997 Resolved
Attach new retro-reflective material on both life floats.
Condition: Unknown
Due 17 July 1997
Resolved 17 July 1997
Fire Fighting
Issued 2 August 1996 Resolved
Service B-II portable fire extinguisher located in cabin just forward of main cabin.
Condition: Unknown
Due 2 August 1996
Resolved 2 August 1996
Construction/Loadline
Issued 2 August 1996 Resolved
Replace missing valve handwheel on bilge line from bow compartment, valve located just aft of collision bulkhead.
Condition: Unknown
Due 2 August 1996
Resolved 2 August 1996
Construction/Loadline
Issued 2 August 1996 Resolved
Strengthen bottom support for deck plating located below ladder to engine space.
Condition: Unknown
Due 2 August 1996
Resolved 2 August 1996
Construction/Loadline
Issued 12 June 1996 Resolved
Replace valve handle on collision bulkhead bilge line.
Condition: Unknown
Due 12 June 1996
Resolved 12 June 1996
Engineering
Issued 12 June 1996 Resolved
Stencil emergency fuel shut-offs.
Condition: Unknown
Due 12 June 1996
Resolved 12 June 1996
Engineering
Issued 12 June 1996 Resolved
Install new intake hoses on main diesel engine and ensure hoses are double clamped where connected.
Condition: Unknown
Due 12 June 1996
Resolved 12 June 1996
Electrical
Issued 12 June 1996 Resolved
Replace missing electrical panel cover.
Condition: Unknown
Due 12 June 1996
Resolved 12 June 1996
Construction/Loadline
Issued 12 June 1996 Resolved
Replace all (6) weathertight hatch gaskets.
Condition: Unknown
Due 12 June 1996
Resolved 12 June 1996
Electrical
Issued 12 June 1996 Resolved
Remove all dead-end wiring near electrical panel.
Condition: Unknown
Due 12 June 1996
Resolved 12 June 1996
Electrical
Issued 12 June 1996 Resolved
Repair or replace battery charge voltage regulator.
Condition: Unknown
Due 12 June 1996
Resolved 12 June 1996
Accommodation/Occupational Safety
Issued 28 April 1995 Resolved
INSTALL PROPER EXHAUST VENTILATION IN LAZERETT EXTENDING DOWN TO THE BILGE AREA FOR PROPER CROSS VENTILATION OF THE FUEL TANK SPACE.
Condition: Unknown
Due 6 June 1995
Resolved 6 June 1995
Accommodation/Occupational Safety
Issued 28 April 1995 Resolved
REMOVE OIL SOAKED PLYWOOD DECK FROM THE OUT BOARD SIDES OF THE ENGINEROOM AND REPLACE WITH EITHER ALUMINUM OR STEEL DECK PLATE.
Condition: Unknown
Due 6 June 1995
Resolved 6 June 1995
Electrical
Issued 28 April 1995 Resolved
INSTALL PROPER BATTERY BOXES TO PROTECT BATTERIES FROM FALLING OBJECTS.
Condition: Unknown
Due 6 June 1995
Resolved 6 June 1995
Engineering
Issued 8 October 1992 Resolved
REPLACE BOTH FUEL OIL FILL NON-METALLIC HOSES IN ENGINEROOM WITH CG APPROVED HOSES FOR FUEL OIL.
Condition: Unknown
Due 8 October 1992
Resolved 8 October 1992
Electrical
Issued 8 October 1992 Resolved
REPLACE TWO LIGHTS IN MAIN CABIN AND ONE LIGHT IN THE WHEELHOUSE WITH UL APPROVED TYPE LIGHTS.
Condition: Unknown
Due 8 October 1992
Resolved 8 October 1992
Unknown
Issued 14 July 1988 Resolved
REPLACE OR REFILL THE FIRST AID KIT I.A.W. NIOSH OR OSHA.
Condition: Unknown
Due 14 July 1988
Resolved 14 July 1988
Construction/Loadline
Issued 14 July 1988 Resolved
INSTALL WEATHERTIGHT DOOR TO THE AFT ENTRANCE TO THE PASSENGER SEATING AREA I.A.W 46CFR171.124
Condition: Unknown
Due 14 July 1988
Resolved 14 July 1988
Unknown
Issued 14 July 1988 Resolved
PROVIDE NAVIGATION CHARTS AND PUBLICATIONS I.A.W. 46CFR185.20-35
Condition: Unknown
Due 14 July 1988
Resolved 14 July 1988
Unknown
Issued 14 July 1988 Resolved
REPLACE MISSING REACH ROD TO THE FUEL TANK SHUT-OFF VALVE AND LABEL I.A.W. 46CFR182.20-40
Condition: Unknown
Due 14 July 1988
Resolved 14 July 1988
Unknown
Issued 14 July 1988 Resolved
REPLACE VENT FLAMESCREENS ON AFTER DECK I.A.W. 46CFR182.20-35
Condition: Unknown
Due 14 July 1988
Resolved 14 July 1988
Unknown
Issued 14 July 1988 Resolved
PROPERLY SPLICE ALL WIRING CONNECTIONS TO THE MAIN CONTROL CONSOLE I.A.W 46CFR183.01-15
Condition: Unknown
Due 14 July 1988
Resolved 14 July 1988
Unknown
Issued 14 July 1988 Resolved
MAKE ALL NAVIGATION LIGHTS INTO COMPLIANCE WITH THE TECHNICAL REQUIREMENTS OF THE COLREGS
Condition: Unknown
Due 14 July 1988
Resolved 14 July 1988
Unknown
Issued 14 July 1988 Resolved
PROVIDE PLUGS TO CLOSE VENTS ON THE AFTER DECK IN CASE OF ADVERSE WEATHER CONDITIONS.
Condition: Unknown
Due 14 July 1988
Resolved 14 July 1988
Unknown
Issued 14 July 1988 Resolved
LOCATE EXHAUST LINE LEAK FROM THE GENERATOR IN AFTER STEERING AND MAKE A WELDED REPAIR.
Condition: Unknown
Due 14 July 1988
Resolved 14 July 1988
Unknown
Issued 14 July 1988 Resolved
PAINT THE NAME AND HAILING PORT OF THE VESSEL ON THE STERN O CONTRASTING COLOR.
Condition: Unknown
Due 14 July 1988
Resolved 14 July 1988
Unknown
Issued 14 July 1988 Resolved
INSTALL PROPER FLOAT FREE LINK TO ATTACH LIFEFLOATS TO VESSEL I.A.W. 46CFR180.20 (VESSEL ROUTE RESTRICTED TO SAIPAN HARBOR UNTIL CORRECTED)
Condition: Unknown
Due 14 July 1988
Resolved 14 July 1988
Unknown
Issued 14 July 1988 Resolved
REPLACE BATTERIES IN ALL LIFEJACKET AND RING BUOY LIGHTS, AND REPLACE THE LIGHTBULBS IN THE NAVIGATION LIGHTS WITH BULBS OF 25 WATT OR GREATER.
Condition: Unknown
Due 14 July 1988
Resolved 14 July 1988
Unknown
Issued 14 July 1988 Resolved
REPLACE PASSENGER CABIN FIRE EXTINGUISHER WITH A COAST GUARD CLASS BII, PROVIDE SERVICING OF ALL OTHER FIRE EXTINGUISHERS.
Condition: Unknown
Due 14 July 1988
Resolved 14 July 1988
Unknown
Issued 14 July 1988 Resolved
PROVIDE PORTABLE HAND OPERATED FIRE AND BILGE PUMP WITH A MINIMUM CAPACITY OF 5 GPM. (ROUTE RESTRICTED TO SAIPAN HARBOR UNTIL CORRECTED)
Condition: Unknown
Due 14 July 1988
Resolved 14 July 1988
Lifesaving
Issued 17 July 1987 Resolved
PROVIDE 9 COAST GUARD APPROVED TYPE 1 PFD'S WITH LIGHTS. UNTIL THIS ITEM COMPLETED, VESSEL MAY NOT CARRY OVER 40 PASSENGERS.
Condition: Unknown
Due 17 July 1987
Resolved 17 July 1987
Lifesaving
Issued 17 July 1987 Resolved
PROVIDE 3 RED FLARES.
Condition: Unknown
Due 17 July 1987
Resolved 17 July 1987
Lifesaving
Issued 17 July 1987 Resolved
CHANGE NAME ON ALL PFD'S TO REFLECT VESSEL'S CURRENT NAME.
Condition: Unknown
Due 17 July 1987
Resolved 17 July 1987
Lifesaving
Issued 17 July 1987 Resolved
REPLACE OTHER BUOYANT APPARATUS LINES WHICH ARE WASTED, AS NECESSARY.
Condition: Unknown
Due 17 July 1987
Resolved 17 July 1987
Electrical
Issued 17 July 1987 Resolved
PROPERLY SECURE COFFEE MAKER.
Condition: Unknown
Due 17 July 1987
Resolved 17 July 1987
Electrical
Issued 17 July 1987 Resolved
REMOVE/REPLACE ALL NON-U.L., MARINE USE EXTENSION CORDS WITH U.L. MARINE USE.
Condition: Unknown
Due 17 July 1987
Resolved 17 July 1987
Electrical
Issued 17 July 1987 Resolved
IN FORWARD PASSENGER COMPARTMENT, PORT, OUTBOARD, MAKE PROPER SPLICES IN ELECTRICAL WIRING.
Condition: Unknown
Due 17 July 1987
Resolved 17 July 1987
Lifesaving
Issued 17 July 1987 Resolved
REPLACE BUOYANT APPRAATUS LIGHT LINE.
Condition: Unknown
Due 17 July 1987
Resolved 17 July 1987
Engineering
Issued 8 June 1987 Resolved
PROVE PROPER OPERATION OF STARBOARD ENGINE FUEL CONTROL ROD.
Condition: Unknown
Due 8 June 1987
Resolved 8 June 1987
Unknown
Issued 20 November 1986 Resolved
CREOP/RENEW/REPLACE WASTED HOLED AREA IN WAY OF KEEL IN LAZARETTE.
Condition: Unknown
Due 20 November 1986
Resolved 20 November 1986
Unknown
Issued 17 October 1986 Resolved
REMOVE WELDING SLAG, ROD BUTTS AND OTHER DEBRIS FROM ALL BILGE AREAS.
Condition: Unknown
Due 17 October 1986
Resolved 17 October 1986
Unknown
Issued 17 October 1986 Resolved
PROVIDE INSULATION PAD FOR PORT MAIN ENGINE INBOARD TURBO.
Condition: Unknown
Due 17 October 1986
Resolved 17 October 1986
Unknown
Issued 17 October 1986 Resolved
REWIRE RANGE BURNERS WITH NEW HEAT RESISTANT WIRE. REMOVE WOOD UNDER COUNTER NEAR BURNERS. STOVE IS NOT TO BE USED UNTIL THIS REQUIREMENT IS COMPLETED.
Condition: Unknown
Due 17 October 1986
Resolved 17 October 1986
Unknown
Issued 17 October 1986 Resolved
PROVIDE BRACKET MOUNT FOR B-II EXTINGUISHER IN ENGINE ROOM.
Condition: Unknown
Due 17 October 1986
Resolved 17 October 1986
Unknown
Issued 17 October 1986 Resolved
LINE BATTERY BOXES BEHIND PILOTHOUSE WITH LEAD OR FIBERGLASS.
Condition: Unknown
Due 17 October 1986
Resolved 17 October 1986
Unknown
Issued 17 October 1986 Resolved
SECURE BATTERY BOX FOR RADAR.
Condition: Unknown
Due 17 October 1986
Resolved 17 October 1986
Unknown
Issued 17 October 1986 Resolved
PROVE OPERATION OF MSD TO HOLDING TANK.
Condition: Unknown
Due 17 October 1986
Resolved 17 October 1986
Unknown
Issued 17 October 1986 Resolved
CHECK/LAP BILGE SUCTION VALVES AS NECESSARY.
Condition: Unknown
Due 17 October 1986
Resolved 17 October 1986
Unknown
Issued 17 October 1986 Resolved
CHECK/FREE UP BILGE SUCTION CHECK VALVES IN EACH COMPARTMENT.
Condition: Unknown
Due 17 October 1986
Resolved 17 October 1986
Unknown
Issued 17 October 1986 Resolved
REMOVE CUTOFF SHORE POWER CABLE UNDER BRIDGE CONSOLE.
Condition: Unknown
Due 17 October 1986
Resolved 17 October 1986
Unknown
Issued 17 October 1986 Resolved
REMOUNT BRACKET FOR B-II FIRE EXTINGUISHER IN AFT PASSENGER COMPARTMENT.
Condition: Unknown
Due 17 October 1986
Resolved 17 October 1986
Unknown
Issued 17 October 1986 Resolved
REPLACE BRACKET FOR WATERLIGHT TO RING BUOY.
Condition: Unknown
Due 17 October 1986
Resolved 17 October 1986
Unknown
Issued 17 October 1986 Resolved
IF CARGO IS TO BE CARRIED, PERFORM A SIMPLIFIED STABILITYH TEST. THIS REQUIREMENT IS TO BE COMPLETED PRIOR TO THE CARRIAGE OF CARGO.
Condition: Unknown
Due 17 October 1986
Resolved 17 October 1986
Unknown
Issued 17 October 1986 Resolved
IF CARGO IS TO BE CARRIED, PLANS ARE TO BE SUBMITTED, APPROVED, ANMD ACCOMPLISHED TO SEPARATE PASSENGER AND CARGO AREAS. THIS REQUIREMENT IS TOBE COMPLETED PRIOR TO THE CARRIAGE OF CARGO.
Condition: Unknown
Due 17 October 1986
Resolved 17 October 1986
Unknown
Issued 17 October 1986 Resolved
FIX GASKET IN LAZARETTE HATCH SO THAT IT STAYS IN PLACE.
Condition: Unknown
Due 17 October 1986
Resolved 17 October 1986
Unknown
Issued 17 October 1986 Resolved
REPAIR GENERATOR EXHAUST LEAK IN LAZARETTE BY WELDING.
Condition: Unknown
Due 17 October 1986
Resolved 17 October 1986
Unknown
Issued 17 October 1986 Resolved
CROP AND RENEW TRANSOM AND INTERVALS IN WAY OF PREVIOUS IMPROPER REPAIRS. THIS REQUIREMENT TO BE COMPLETED BY COMPLIANCE DATE OR NEXT DRYDOCKING, WHICHEVER COMES FIRST.
Condition: Unknown
Due 17 October 1986
Resolved 17 October 1986
Unknown
Issued 17 October 1986 Resolved
REPAIR DENTS (LIFTING SLING) IN CHINE PORT AND STARBOARD JUST FORWARD OF ENGINE ROOM IN AFT PASSENGER COMPARTMENT. THIS IS TO BE COMPLETED BY COMPLIANCE DATE OR NEXT DRYDOCKING, WHICHEVER COMES FIRST.
Condition: Unknown
Due 17 October 1986
Resolved 17 October 1986
Unknown
Issued 17 October 1986 Resolved
PROVIDE PROPER SUPPORT AND BANDING FOR ALL ELECTRICAL WIRING IN THE ENGINE ROOM.
Condition: Unknown
Due 17 October 1986
Resolved 17 October 1986
Unknown
Issued 17 October 1986 Resolved
PROVIDE AND ATTACH 7 ADDITIONAL PFD LIGHTS FOR A TOTAL OF 48.
Condition: Unknown
Due 17 October 1986
Resolved 17 October 1986
Unknown
Issued 17 October 1986 Resolved
PROVIDE 30 X 30 MESH FLAME SCREENS FOR FUEL OIL TANK VENTS.
Condition: Unknown
Due 17 October 1986
Resolved 17 October 1986
Unknown
Issued 17 October 1986 Resolved
POST ORIGINAL CERTIFICATE OF INSPECTION.
Condition: Unknown
Due 17 October 1986
Resolved 17 October 1986
Unknown
Issued 17 October 1986 Resolved
PRODUCE VESSEL'S DOCUMENT AND PLACE ON BOARD VESSEL.
Condition: Unknown
Due 17 October 1986
Resolved 17 October 1986
Unknown
Issued 17 October 1986 Resolved
PROVIDE PAINTERS AND FLOAT FREE LINKS FOR TWO LIFE FLOATS. DO NOT ALLOW ANYTHING TO BE STORED IN LIFEFLOATS EXCEPT EMERGENCY EQUIPMENT.
Condition: Unknown
Due 17 October 1986
Resolved 17 October 1986
Unknown
Issued 17 October 1986 Resolved
STENCIL TWO REMAINING LIFE FLOATS WITH VESSEL'S NAME.
Condition: Unknown
Due 17 October 1986
Resolved 17 October 1986
Unknown
Issued 17 October 1986 Resolved
PROVIDE MOUNTING BRACKET FOR ALL GAUGES IN ENGINE ROOM.
Condition: Unknown
Due 17 October 1986
Resolved 17 October 1986
Documentation
Issued 16 September 1986 Resolved
VESSELS ROUTE IS RESTRICTED TO LAKES, BAYS & SOUNDS, CONFINES OF ISLAND OF GUAM HARBOR AND ISLAND OF TINIAN HARBOR. THIS REQUIREMENT REMAINS IN AFFECT UNTIL VESSEL RECEIVES AMENDMENT SPECIFYING ROUTE.
Condition: Unknown
Due 16 September 1986
Resolved 16 September 1986

Ownership record