Records from 2008 to 2025. Most recent: inspection, 29 October 2025.
Inspection history · 25
29 October 2025
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8162252
1 October 2025
COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8162250
4 November 2024
Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8008783
10 August 2024
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7977042
25 June 2024
Deficiency Check · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7942575
24 June 2024
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8024915
5 January 2024
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7781926
2 November 2023
Deficiency Check · Hull Examination · Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7733593
1 May 2023
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7675589
6 December 2022
Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7580026
17 June 2022
Plan Review "T" Boat
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7589226
2 June 2022
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7466496
10 November 2021
Hull Examination · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7341979
21 October 2021
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7309361
20 April 2021
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7178757
7 October 2020
COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7070954
18 December 2019
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6862947
23 October 2019
Hull Examination · Examination of Repairs · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6789737
5 November 2018
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6550953
10 January 2018
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6313533
26 October 2017
Hull Examination · Internal Structural Exam · Examination of Repairs · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6242466
10 September 2017
In-Service Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6264767
10 September 2017
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6266041
23 April 2017
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6131753
3 January 2017
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6034254
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 October 2025
Resolved
An adult life jacket must be provided for each person carried on board a vessel. (11) life jackets found to be deteriorated and (04) missing. Total persons allowed on board reduced to 98 persons.
Action required: 705 - Other - as specified
Resolved 27 October 2025
Resolution: Vessel replaced missing/deteriorated life jackets.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 1 October 2025
No resolution recorded
Each item of survival craft equipment must be of good quality, and efficient for the purpose it is intended to serve. (01) life float found to be deteriorated and not serviceable. Total persons allowed on board reduced to capacity of remaining serviceable life floats, 100 persons.
Action required: 705 - Other - as specified
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 1 October 2025
Resolved
All cable and wire must be installed with metal supports spaced not more than 610 millimeters (24 inches) apart, and in such a manner as to avoid chafing and other damage. Unsupported cable runs found in fwd bunk room.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 October 2025
Resolved 27 October 2025
Resolution: Vessel added metal cable supports.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 4 November 2024
Resolved
Each individual bilge suction must be fitted with a suitable strainer having an open area of not less than three times that of the suction pipe. Strainer on suction bilge not attached.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 November 2024
Resolved 12 November 2024
Resolution: Recieved phot of strainer attached to bilge suction foot.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 4 November 2024
Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating.
Bilge alarm in the collision bulkhead space did not visually indicate in the operating station.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 November 2024
Resolved 12 November 2024
Resolution: Recieved video of audible and visual alarm in operating station from collision bulkhead location.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 4 November 2024
Resolved
Life floats. Each life float must be fitted with a lifeline, pendants, two paddles, a painter, and a light.
Lifeline on life floats found to be deteriorated and not serviceable.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 November 2024
Resolved 12 November 2024
Resolution: Recieved photo of new life line attached to life float.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 5 January 2024
Resolved
The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located, preferably from an accessible position on the weather deck. Covers for accessing fuel shutoff valves from weather deck were found seized in the closed position and tool for opening cover missing. Crew purchased new tool and made covers operational prior to completing inspection.
Action required: 10 - Deficiency Rectified
Resolved 5 January 2024
Resolution: Crew purchased new tool and made covers operational prior to completing inspection.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 5 January 2024
Resolved
Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. All closure devices must be readily available and mounted in the vicinity of the vent. STBD aft E/R ventilation closure device was being obstructed by deck framing, repair closure device so that it operates properly if needed for closure.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 January 2024
Resolution: Ventilation adjusted to ensure vent closure fully seated.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 5 January 2024
Resolved
An exposed hazard, such as gears or rotating machinery, must be properly protected by a cover, guard, or rail. Aft generator prime mover belt guard was found unattached. Reattached guard to prevent accidental exposure to rotating machinery.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 January 2024
Resolution: Guard reattached
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 5 January 2024
Resolved
Each buoyant apparatus must be fitted with a lifeline, pendants, a painter, and a light. Painter for STBD BA stack was found wasted; replace painter line (Line must be 100ft, breaking strength of at least 1,500 pounds, dark in color, and be stowed in such a way that it runs out freely.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 January 2024
Resolution: New painter line attached to L/F stack
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 5 January 2024
Resolved
Fuel lines must be accessible, protected from mechanical injury, and effectively secured against excessive movement and vibration by the use of soft nonferrous metal straps which have no sharp edges and are insulated to protect against corrosion. Forward generator prime mover high pressure fuel line was found chaffing against pipe clamp supports and had damaged high pressure fuel line. Replace fuel line or provide report attesting to its serviceability for fuel delivery pressure.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 January 2024
Resolution: High resolution photo provided that showed only paint chaffed and not ferrous material, rail support repositioned to fully support rail.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 December 2022
Resolved
Fuel filter and strainer bowls must be highly resistant to shattering due to mechanical impact and resistant to failure due to thermal shock. Flame screens have plastic drain plugs installed.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 December 2022
Resolution: Fixed prior to inspection team departure.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 6 December 2022
Resolved
Each ring life buoy on a vessel must: carry one floating water light. The water light attached to the life ring does not illuminate.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 December 2022
Resolution: Fixed prior to inspection team departing.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 6 December 2022
Resolved
The equipment required for lifefloats and
buoyant apparatus must meet the following specifications: The light must be a floating waterlight approved under approval series 161.010 or other
standard specified by the Commandant. Waterlight attached to the lifefloat did not illuminate.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 December 2022
Resolution: Fixed prior to inspection team departing.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of Lifeboats
Issued 6 December 2022
Resolved
Each life float and buoyant apparatus must be stowed as required under this section... The float free link secured to the painter at one end and the vessel on the other end. The float free link was not attached to the vessel.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 December 2022
Resolution: Fixed prior to inspection team departing.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 December 2022
Resolved
A bilge suction must be fitted with a suitable strainer having an open area not less than three times the area of the bilge pipe. Bilge suctions to not have strainers attached.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 December 2022
Resolved 20 January 2023
Resolution: Operator has installed new bilge suction strainers.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 6 December 2022
Resolved
The following spaces must be equipped with a fixed gas fire extinguishing system approved by the Commandant: A space containing propulsion machinery. MI could not locate approval letter for installed CO2 system. Submit CO2 system specifications to verify that installed system is approved.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 January 2023
Resolved 20 January 2023
Resolution: Vessels CO2 system is oversized a sufficient amount such that a shut down is not required.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 21 October 2021
Resolved
All machinery and equipment must be maintained in such a manner to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Fuel filter (centerline in front of #1 generator) dripping fuel.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 21 October 2021
Resolved 21 October 2021
Resolution: Crew adjusted filter and stopped dripping.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 21 October 2021
Resolved
System design and installation must be in accordance with the Marine Design, Installation, Operation, and Maintenance Manual approved for the system by the Commandant. A full operational test performed on shutdowns for machinery, ventilation and dampers. Forward engine room overhead (port and starboard side) vent flaps could not be fully shut during test.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 November 2021
Resolved 4 November 2021
Resolution: Vents able to press flat on overhead surfaces.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 21 October 2021
Resolved
Each life float must be fitted with a lifeline, pendants, two paddles, a painter and a light. Life Float pendant lines appeared deteriorated and broke when pulled by the inspector (stbd, bottom float). (Life float pendants must be fitted appx 18 inches apart around the outside of the float, made up in hanks, each must be at least 1/4" diameter and 12' long, secured in the middle and have a breaking strength of at least 540 lbs, or, per the manufacturers guidance)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 November 2021
Resolved 10 November 2021
Resolution: Pendants replaced as needed.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 21 October 2021
Resolved
Each lighting fixture globe, lens, or diffuser must have a guard or be made of high strength material, except in an accommodation space, radio room, galley, or similar space where it is not subject to damage, and protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment. Globe missing for service lights (One in forward crew space, one in port forward lazarette).
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 November 2021
Resolved 10 November 2021
Resolution: Globe installed.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 18 December 2019
Resolved
All griddles, broilers, and deep fat fryers must be fitted with a grease extraction hood in compliance with 181.425. A grease extraction hood must meet ul 710 or other standard specified by the commandant. A grease extraction hood must be equipped with a dry or wet chemical fire extinguishing system meeting NFPA 17 or other standard specified by the commandant and must be listed by an independent lab recognized by the commandant. Vessel is required to disconnect and cease use of griddle / cooking apparatus immediately and propose in writing plan to permanently remove such equipment or install approved system in accordance with regulations within two weeks.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 January 2020
Resolved 20 April 2021
Resolution: O/O diconnected griddle from electrical panel and secured wiring to the satisfaction of the attending MI.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 23 October 2019
Resolved
Cylinders which are fitted with a siphon may be inclined not more than 80 degrees. Provide proof of installed siphon tube and proper orientation of installation.
701c, 46 CFR 181.20-30
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 November 2019
Resolution: Relocated and serviced, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 October 2019
Resolved
Life preservers shall be distributed through the upper part of the vessel in protected spaces convenient to persons onboard. Life jackets forchildren and 74 adult life jackets are stowed in storage space below main deck. Provide proposal to relocate life jackets to meet regulation.
701c, 46 CFR 180.25-10
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 November 2019
Resolution: All required lifejackets relocated to above deck, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 5 November 2018
Resolved
FOUND LIFE FLOAT WITH 4" TEAR ON THE BODY. PROVIDE PROOF LIFE FLOAT IS IN GOOD AND SERVICEABLE CONDITION TO THE SATISFACTION OF THE ATTENDING USCG MARINE INSPECTOR.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 November 2018
Resolved 21 November 2018
Resolution: PROVIDED PROOF OF LIFE FLOAT TEAR VIA EMAIL. ALL SAT.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 10 January 2018
Resolved
Annual Fire Fighting Service mehtod was found incomplete and service documentations innaccurate. 46CFR176.810(B)(2)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 January 2018
Resolved 11 January 2018
Resolution: Servicing company re-serviced system and issued new servicing report.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 10 January 2018
Resolved
Found CO2 hoses on both bottles installed at a 25 degree bend and found the hoses to be cracked from age. 46CFR147.65
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 January 2018
Resolved 11 January 2018
Resolution: Hoses were all replaced with new.
Fire Fighting › Fire Pumps › Suction Valve
Issued 26 October 2017
Resolved
Replace Washdown/firepump skin valve.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 November 2017
Resolved 20 November 2017
Resolution: Replaced bad valve with new ball valve.
Construction/Loadline › Hull › Keel
Issued 26 October 2017
Resolved
Complete renewal of keel bolts.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 November 2017
Resolved 20 November 2017
Resolution: All iron keel bolts have been replaced with silicon bronze.
Engineering › Sea-water System (primary cooling) › Valve
Issued 26 October 2017
Resolved
Clean all gate valve seats.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 November 2017
Resolved 20 November 2017
Resolution: All gate valves have been replaced with new ball valves.
Construction/Loadline › Hull › Transverse Frame
Issued 26 October 2017
Resolved
Scrape and treat bilge area IWO port,stbd shaft seals.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 November 2017
Resolved 20 November 2017
Resolution: Bilge areas were scraped and treated.
Construction/Loadline › Hull › Strut/Cross Tie
Issued 26 October 2017
Resolved
Repair backing block for port aft strut.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 November 2017
Resolved 20 November 2017
Resolution: Backing block for strut was renewed.
Construction/Loadline › Hull › Transverse Frame
Issued 26 October 2017
Resolved
Scrape and treat bottom transom log.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 November 2017
Resolved 20 November 2017
Resolution: Transom log was scraped/treated and re-fastened.
Stability › Watertight Integrity › General
Issued 26 October 2017
Resolved
Conduct satisfactory sea trial.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 November 2017
Resolved 22 November 2017
Resolution: Coducted satifactory sea trial.
Engineering › Steering Gear System › Follow-up Assembly
Issued 11 September 2017
Resolved
Port engine resulted in no auxiliary means of steering. Vessel is to provide auxiliary means of steering or make port main engine operational prior to operating with passengers. Vessel is no sailed.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 September 2017
Resolution: Attended vessel and observed the replacement of the port main engine starting solenoid. Operational test and underway sea trail conducted. All sat.