MAURY USCG vessel records Sign in
← All vessels

HC JADE

HC JADE is a 1996 freight ship. The Coast Guard has recorded 105 inspections since 1997, most recently in April 2024, along with 61 deficiencies and 24 operational controls.

Records from 1997 to 2024. Most recent: inspection, 6 April 2024.

Built
1996
Last inspected
6 April 2024
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9160504 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
466608
Flag
MALDIVES
—
Maury page id
psix-466608

Inspections, by type

…with no type recorded74
Years with a record 15 calendar years (1997–2024)
The 105 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it4028 - Convention (Subpart B), Gross Ton
5250 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 105

6 April 2024 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7890974
5 May 2012 MARPOL Annex I Examination · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4302226
3 May 2012 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4304969
18 November 2010 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3893468
18 November 2010 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3893856
18 March 2010 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3697652
12 January 2010 ISPS II Exam · MARPOL Annex I Examination · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3662509
1 May 2009 ISPS II Exam · PII Safety Exam · MARPOL Annex I Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3465039
1 May 2009 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3467790
3 December 2008 Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 3373204
5 June 2008 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3228036
11 April 2008 Ballast Water Examination · PII Safety Exam · MARPOL Annex I Examination · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3181816
28 March 2008 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3173024
26 March 2008 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3171420
13 March 2008 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3163634
12 March 2008 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3163156
27 February 2008 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3155610
14 February 2008 Type not recorded
No type recorded · Maritime Safety & Security Team Miami (91114) · Activity 3147430
31 January 2008 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3139990
30 January 2008 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3139306
8 January 2008 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3126742
7 January 2008 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3126471
28 December 2007 Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3121756
7 December 2007 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3111276
9 November 2007 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3096618
13 September 2007 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3070233
13 September 2007 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3072631
2 May 2007 Type not recorded
No type recorded · Station Miami Beach · USCG Southeast District (CGD-SE) · Activity 2921000
29 April 2007 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2918465
5 April 2007 PII Safety Exam · ISPS II Exam · MARPOL Annex I Examination · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3043904
24 August 2006 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2758732
8 August 2006 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2740029
7 August 2006 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2738453
19 July 2006 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2717869
6 July 2006 Type not recorded
No type recorded · Station Fort Lauderdale · USCG Southeast District (CGD-SE) · Activity 2740378
3 July 2006 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2700031
27 June 2006 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2692993
21 June 2006 Type not recorded
No type recorded · Station Fort Lauderdale · USCG Southeast District (CGD-SE) · Activity 2686852
21 June 2006 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2687162
19 June 2006 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2684448
16 May 2006 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2650914
4 May 2006 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2640345
3 May 2006 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2640387
12 April 2006 Type not recorded
No type recorded · Station Fort Lauderdale · USCG Southeast District (CGD-SE) · Activity 2622930
11 April 2006 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2622276
6 April 2006 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2619154
15 March 2006 Type not recorded
No type recorded · Station Fort Lauderdale · USCG Southeast District (CGD-SE) · Activity 2602765
14 March 2006 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2602135
1 March 2006 MARPOL Annex I Examination · Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2593743
23 January 2006 ISPS II Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2571338
18 January 2006 ISPS II Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2556130
3 January 2006 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2559826
14 October 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2515930
26 September 2005 ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2501143
26 September 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2501464
22 September 2005 Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2498456
25 July 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2438979
6 June 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2381917
28 May 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2371153
5 May 2005 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2356892
3 April 2005 Type not recorded
No type recorded · Station Fort Lauderdale · USCG Southeast District (CGD-SE) · Activity 2326721
26 March 2005 Type not recorded
No type recorded · Station Fort Lauderdale · USCG Southeast District (CGD-SE) · Activity 2326594
15 March 2005 Ballast Water Examination · MARPOL Annex V Examination · ISPS III Exam · MARPOL Annex I Examination · PII Safety Exam
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2310988
2 March 2005 Type not recorded
No type recorded · Station Fort Lauderdale · USCG Southeast District (CGD-SE) · Activity 2302755
17 December 2004 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2261584
31 October 2004 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2231840
20 October 2004 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2224673
18 October 2004 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2223145
12 October 2004 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2219975
5 October 2004 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2214261
26 September 2004 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2206665
24 September 2004 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2203843
11 September 2004 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2193195
10 September 2004 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2192688
17 August 2004 PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2168349
17 August 2004 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2168591
14 July 2004 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2132844
2 July 2004 ISPS II Exam
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2118952
26 April 2004 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2060464
11 February 2004 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2004829
31 January 2004 Annual Inspection · Ballast Water Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1999098
4 November 2003 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1943141
15 October 2003 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1924885
10 September 2003 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1896494
30 August 2003 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1891533
25 August 2003 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1886755
29 July 2003 MARPOL Annex I Examination · Ballast Water Examination · Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1858223
5 April 2003 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1768684
24 January 2003 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1734799
14 September 2002 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1675447
24 July 2002 Ballast Water Examination · Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1650568
16 February 2002 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1487081
16 January 2002 Ballast Water Examination · Annual Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1479248
13 March 2001 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 288100
27 February 2001 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 287560
17 January 2001 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 285944
15 December 1999 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 435709
4 January 1999 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 424972
1 December 1998 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 422936
25 August 1998 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 419469
24 August 1998 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 118584
2 June 1998 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 416646
21 November 1997 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 409940
27 October 1997 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 725463
26 October 1997 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 409263

Deficiency record · 61

Pollution Prevention/Response › Prevention Equipment › Oily Mixture Discharge Fixed Piping System
Issued 7 May 2012 Resolved
A certificate issued under regulation 7 or 8 of this annex shall cease to be valid... if the relevant surveys are not completed within periods given under reg 6.1. An additional survey either general or partial... shall be made... whenever any important repairs or renewals are made. Changes made to piping to include incinerator sludge in oily water holding system, not approved. MARPOL 73/78 I 10.9
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 July 2012
Resolution: Received report from GL. Verified onboard vsl.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 7 May 2012 Resolved
Discharge of oil or oily mixtures from ships shall be prohibited except when the oil content does not exceed 15 PPM and through an approved OWS system. There is evidence that the crew has used the oily water transfer pump and a make-shift hose to bypass the oily water separator and discharge oil and/or oily water directly overboard. (MARPOL 73/78 I REG 15)
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 20 July 2012
Resolution: Received report from GL. Verified onboard vsl.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 5 May 2012 Resolved
Contracting governments undertake each for its national ships, to maintain, or if necessary adopt safety measures to ensure all ships shall be sufficiently and efficiently manned. Vessel missing one deck watch officer, replacement not yet onboard. (74 SOLAS (09 Cons) V/14.1)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 May 2012
Resolution: Vsl received exemption from flag to sail out of Miami without deck officer.
Documentation › Logs/Records › Oil Record Book
Issued 5 May 2012 Resolved
The oil record book shall be completed on each occasion and signed by the officer in charge and master. Oil record book has not been signed by master since January 2012 although operations have continued through April 23, 2012. (MARPOL 06 Annex 1/17.4)
Action required: 705 - Other - as specified
Due 19 May 2012
Resolved 6 April 2024
Resolution: Vessel has been on hold since September of 2013 with minimal to no crew, as such no new entries were recorded. Vessel is being allowed to depart and resume operations.
Documentation › Logs/Records › Ballast Water Logs/Records
Issued 5 May 2012 Resolved
Vessels entering US waters after operating beyond the EEZ shall complete and submit ballast water reports to NBW Clearing House as required. Found vessel missing numerous BWE reports. (33CFR 151.2035)
Action required: 15 - Rectify deficiencies by next port
Resolved 1 April 2015
Resolution: Vessel has since changed owners/crew and reflagged. New owners/crew were provided with guidance on BWM practices despite owner''s claim that vessel will not be returning to service in the U.S.
Engineering › Fuel Oil Service System › Pump
Issued 5 May 2012 Resolved
Machinery and associated pipes and fittings shall be adequate for the service intended and installed and protected to reduce dangers onboard. Found several fuel oil pumps on the mail engine to be leaking fuel onto sections of engine and running down the sides. (74 SOLAS (09 Cons) II-2/26.1
Action required: 705 - Other - as specified
Due 19 May 2012
Resolved 6 April 2024
Resolution: Attending PSCO verified correction of fuel oil pump leaks on the main engine.
Stability › Watertight Integrity › General
Issued 12 January 2010 Resolved
Vessels anchor has punctured hull area surrounding anchor housing, resulting in a 8 inch rupture of the hull. This rupture allows water to enter the boson’s locker freely (2ft of water accumulated during voyage)
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 November 2010
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 1 May 2009 Resolved
Vessel missing two personnel. One deck rating and one forming part of a navigational watch.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 May 2009
Resolution: Certificates were faxed to this Sector Miami
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 2 April 2009 Resolved
33U.S.C.1321(j)(5)(G)-The vessel owner/operator has not provided certification ensuring that response resources are capable of responding to the maximum extent practicable, to a worst case discharge. 33U.S.C.1321(j)(5)(D)(i)-Due to the publication of the tech amendments to 33 CFR Part 3, the COTP zone names need to be updated to reflect this amendment.
Due 2 May 2009
Resolved 4 September 2009
Resolution: Plan holder provided a signed certification statement and updated plan to reflect the new COTP zone names. Vessel issued Interim Operating Authorization expiring 9/4/2011.
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 5 June 2008 Resolved
Vsl lost port side anchor and 2 shots of chain
Action required: 705 - Other - as specified
Due 19 June 2008
Resolved 19 November 2010
Electrical › Electrical Distribution System (service) › Wiring
Issued 11 April 2008 Resolved
Electrical boxes on deck, portside, have exposed wires and are covered with plastic bags.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 May 2008
Resolved 5 June 2008
Resolution: Vsl replaced electrical boxes.
Fire Fighting › Fire Hoses › Condition
Issued 11 April 2008 Resolved
Fire boxes on port side have broken hinges. Fire hoses and tools are exposed to the elements.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 April 2008
Resolved 5 June 2008
Resolution: Vsl repaired boxes.
Accommodation/Occupational Safety › Medical/First Aid › Hospital Space
Issued 11 April 2008 Resolved
Hospital space unsecured with key in medical locker. Assorted ship's supplies stowed on hospital bed and floor making use of room difficult.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 April 2008
Resolved 11 April 2008
Resolution: Removed materials from hospital space.
Engineering › Diesel Engine (propulsion-direct drive) › Bearing
Issued 8 August 2006 Resolved
vessel is at berth 6 Port Everglades. Engine crank shaft is broken and will be repaired and tested docksidew/ sea trials to follow.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 8 November 2006
Engineering › Lubricating Oil Service System › Expansion Joint
Issued 6 April 2006 Resolved
Compensator on Main Engine lube system has a malfunction and needs to be replaced. This part was replaced 2 months ago and failed again. Provide class survey report attesting to the proper operation of main engine lube oil system . Ensure class addresses the reason for the reoccuring malfunction.
Action required: 17 - Rectify deficiencies prior to departure
Due 6 April 2006
Resolved 6 April 2006
Resolution: Received class report attesting to the repairs.
Documentation › Safety Management System › Conformity Maintenance Procedures
Issued 1 March 2006 Resolved
vessel's safety management plan does not specify if hot work checklist must be completed when non-crew (contractor) is conducting hot work aboard vessel. The marine inspector requests that the vessel's recognized organization attend vessel and clarify.
Action required: 705 - Other - as specified
Due 21 April 2006
Resolved 21 June 2006
Documentation › Safety Management System › Conformity Maintenance Procedures
Issued 1 March 2006 Resolved
vessel's safety management plan does not specify if hot work check list must be completed when non-crew (contractor) is conducting hot work aboard vessel. The marine inspector requests that the vessel's recognized organization attend vessel and clarify
Action required: 705 - Other - as specified
Due 15 March 2006
Resolved 6 April 2006
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 15 March 2005 Resolved
LIFEBOUY PORT SIDE REPLACE OR FIX LIGHT.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 16 April 2005
Resolved 5 May 2005
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 15 March 2005 Resolved
TOILET IN BOSN LIVING SPACE INOPERABLE
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 16 April 2005
Resolved 5 May 2005
Accommodation/Occupational Safety › Medical/First Aid › Hospital Space
Issued 15 March 2005 Resolved
TOILET INOPERABLE IN SICK BAY
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 16 April 2005
Resolved 5 May 2005
Engineering › Diesel Engine (propulsion-electric)
Issued 10 September 2003 Resolved
#7 Cylinder on main diesel engine has high pressure fuel leak. LEGACY COMPONENT DESC: Cylinder
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 12 September 2003
Engineering › Shafting/Propeller Arrangements
Issued 10 September 2003 Resolved
#1 CPP supply piping leaking at flange. LEGACY COMPONENT DESC: Propeller (controllable pitch)
Action required: 705 - Other - as specified
Resolved 12 September 2003
Engineering › Shafting/Propeller Arrangements
Issued 10 September 2003 Resolved
Hydrolic fluid leaking onto #1 CPP pump. LEGACY COMPONENT DESC: Propeller (controllable pitch)
Action required: 705 - Other - as specified
Resolved 12 September 2003
Engineering › Bilge Water Management System
Issued 10 September 2003 Resolved
Excessive oil in bilges.
Action required: 705 - Other - as specified
Resolved 12 September 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 10 September 2003 Resolved
Excessive oil/hydrolic fluid on deck plating. LEGACY COMPONENT DESC: Deck Rail
Action required: 705 - Other - as specified
Resolved 12 September 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 10 September 2003 Resolved
Repair/secure handrail leading down to lower level of engine room. LEGACY COMPONENT DESC: Deck Rail
Action required: 705 - Other - as specified
Due 11 October 2003
Resolved 12 September 2003
Engineering › Fuel Oil Service System
Issued 10 September 2003 Resolved
Renew sediment discharge flexible connectors on #2 HFO and DO seperator. 12 Sep 03, recieved copy of ships oder requesting new flex connectors. LEGACY COMPONENT DESC: Filter
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 October 2003
Resolved 15 October 2003
Resolution: Boarded vessel and observed the flexible connectors in place.
Accommodation/Occupational Safety › Occupational Safety
Issued 10 September 2003 Resolved
Renew overhead light fixture in funnel space on the main deck.
Action required: 705 - Other - as specified
Due 11 October 2003
Resolved 12 September 2003
Engineering › Diesel Engine (auxiliary)
Issued 29 July 2003 Resolved
#3 Ship Service Diesel Generator prime mover high pressure fuel oil pump leaking, provide class society report prior to departure from the port of Jacksonville Fl. LEGACY COMPONENT DESC: Pump, High Pressure (fuel injection)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 July 2003
Resolution: Crew repaired pump, BV surveyor and duty inspector attended, repairs satisfactory, detention lifted.
Engineering › Fuel Oil Service System
Issued 29 July 2003 Resolved
renew sedement discharge fexible connectors on #2 FFO Seperator and DO seperator. LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Due 29 August 2003
Resolved 12 September 2003
Electrical › Lighting (service)
Issued 29 July 2003 Resolved
Renew overhead light fixture cover in Seperator room, #3 from starboard side. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Unknown
Due 29 August 2003
Resolved 12 September 2003
Operations/Management › Pollution
Issued 29 July 2003 Resolved
Clean bilges in machinery space, seperator room and generator flat. LEGACY COMPONENT DESC: Removal Methods/Procedures
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 12 September 2003
Electrical › Electric Generation Source (emergency)
Issued 24 January 2003 Resolved
Prove proper operation of emergency generator IAW 33 CFR 164.25 (A) (VII). Prior to departure from port. Fax copy to MSO Miami from Bureau Veritas (BV) attesting to repair and Satisfactory test of emergency generator in manual and automatic modes. LEGACY COMPONENT DESC: Power Requirement
Action required: 17 - Rectify deficiencies prior to departure
Due 24 January 2003
Resolved 24 January 2003
Resolution: Received fax from BV.
Engineering › Lubricating Oil Service System
Issued 24 July 2002 Resolved
No lagging on thermal oil heating system (E/R STBD side aft). Install lagging on system.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 24 August 2002
Resolved 14 September 2002
Resolution: cleared
Engineering
Issued 24 July 2002 Resolved
Emergency escape trunk does not automatically shut. Device missing. Ensure proper operation of doors prior to due date.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 September 2002
Resolved 14 September 2002
Resolution: cleared
Engineering › Fuel Oil Storage/Transfer System
Issued 24 July 2002 Resolved
Temporary tubing vent from HFO day tank. Replace/make permanent repairs. LEGACY COMPONENT DESC: Vent Pipe
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 24 August 2002
Resolved 14 September 2002
Resolution: cleared
Engineering › Fuel Oil Storage/Transfer System
Issued 24 July 2002 Resolved
HFo settling tank #1 leaking from bottom outboard. LEGACY COMPONENT DESC: Tank
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 August 2002
Resolved 14 September 2002
Resolution: cleared
Engineering › Sea-water System (primary cooling)
Issued 24 July 2002 Resolved
#2 LTFW cooling Pump electric connection improper. LEGACY COMPONENT DESC: Pump
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 August 2002
Resolved 14 September 2002
Resolution: cleared
Engineering
Issued 24 July 2002 Resolved
Temporary wiring rigged in E/R lower level through emergency escape trunk. Remove prior to due date.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 August 2002
Resolved 14 September 2002
Resolution: cleared
Pollution Prevention/Response › Prevention Equipment
Issued 24 July 2002 Resolved
OWS is inoperable. Provide class documentation attesting to proper operation or stating that vsl may continue without properly operating OWS. CG inspectors to verify that OWS is operational in next US Port. Also, CG inspector must verify that vsl is pumping the sludge tank out every 10 days. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 22 August 2002
Resolved 14 September 2002
Resolution: cleared
Pollution Prevention/Response › Prevention Equipment
Issued 24 July 2002 Resolved
Excessive oil in vicinity of OWS. Clean up prior to 24 Aug 02. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 August 2002
Resolved 14 September 2002
Resolution: cleared
Electrical › Lighting (service)
Issued 16 January 2002 Resolved
Dead end wire in Emergency Generator Room. Remove or repair to satisfaction of Class Society prior to 16Feb02.
Action required: 705 - Other - as specified
Due 16 February 2002
Resolved 12 February 2002
Resolution: New lighting fixture has been attached and tested to satisfaction of class society. Cleared by fax from Class Society.
Accommodation/Occupational Safety › Occupational Safety
Issued 16 January 2002 Resolved
No Safety Mat in front of Emergency Switch Board. Provide class report of approval prior to 16Feb02.
Action required: 705 - Other - as specified
Due 16 February 2002
Resolved 12 February 2002
Resolution: Safety mat was installed in front of emergency swithboard. Cleared by fax from Class society.
Accommodation/Occupational Safety › Occupational Safety
Issued 16 January 2002 Resolved
Non-Slip surface in Emergency Generator Room missing. Provide class acceptance/approval prior to 16Feb02.
Action required: 705 - Other - as specified
Due 16 February 2002
Resolved 12 February 2002
Resolution: Non slip mat was installed in emergency generator room. Cleared by fax from Class Society.
Construction/Loadline › Markings
Issued 16 January 2002 Resolved
Loadline not marked IAW Certificate. Provide Class report of acceptance prior to 16Feb02. LEGACY COMPONENT DESC: Load Line Mark
Action required: 705 - Other - as specified
Due 16 February 2002
Resolved 12 February 2002
Resolution: Loadline was marked correctly on Port and Starboard to satisfaction of class society. Cleared by fax from Class Society.
Deck/Cargo › Mooring/Anchoring
Issued 16 January 2002 Resolved
Hydraulic leak from Hydraulic winch. Leak is in the overhead of Emergency Generator Room. Provide class report prior to 16Feb02. LEGACY COMPONENT DESC: Winch
Action required: 705 - Other - as specified
Due 16 February 2002
Resolved 12 February 2002
Resolution: New Piping was installed. Cleared by fax from Class Society.
Accommodation/Occupational Safety
Issued 17 January 2001 Resolved
TYPE II MSD INOPERABLE DUE TO THE CONTACTOR SWITCH FOR THE SUPPLY PUMP MISSING. REPAIR PRIOR TO 17 FEB 01.
Condition: Unknown
Due 27 February 2001
Resolved 28 February 2001
Lifesaving
Issued 1 December 1998 Resolved
REMOVE PAINT FROM LOWER ENGINE SPACES
Condition: Unknown
Due 14 January 1999
Resolved 14 January 1999
Navigation
Issued 1 December 1998 Resolved
MAKE REPAIRS TO INOPERABLE STBD BRIDGE WING GRYO COMPASS REPEATER AND PROVIDE CLASS REPORT.
Condition: Unknown
Due 14 January 1999
Resolved 14 January 1999
Engineering
Issued 25 August 1998 Resolved
VESSEL LOST PITCH CONTROL DUE TO FIRE IN ELECTRICAL PANEL. VESSEL TO MAKE PERMANENT REPAIRS TO AND COMPLETE SATISFACTORY TESTS OF BOTH CONTROLLABLE PITCH PROPELLER PUMPS TO SATISFACTION OF CLASSIFICATION SOCIETY. CLASS MUSTSUBMIT REPORT OF REPAIRS TO MSO JACMS PRIOR TO VESSEL DEPARTURE.
Condition: Unknown
Due 25 August 1998
Resolved 25 August 1998
Navigation
Issued 26 October 1997 Resolved
Pre-arrival and departure test not logged in accordance with 33CFR164.25.
Condition: Unknown
Due 21 November 1997
Resolved 21 November 1997
Lifesaving
Issued 26 October 1997 Resolved
Steering gear test/drills not logged in accordance with SOLAS 74 AMENDED_x001C_ V/19-2.
Condition: Unknown
Due 21 November 1997
Resolved 21 November 1997
Lifesaving
Issued 26 October 1997 Resolved
Abandon ship/fire drills not logged in accordance with SOLAS 74 AMENDED_x001C_ III 18.3,18.5.
Condition: Unknown
Due 21 November 1997
Resolved 21 November 1997
Lifesaving
Issued 26 October 1997 Resolved
Life saving equipment including lifeboats not examined and logged in accordance with SOLAS 74 AMENDED III 19.7.
Condition: Unknown
Due 21 November 1997
Resolved 21 November 1997
Navigation
Issued 26 October 1997 Resolved
No maneuvering fact sheet with warning statement on bridge in accordance with 33CFR164.35(G).
Condition: Unknown
Due 21 November 1997
Resolved 21 November 1997
Documentation
Issued 26 October 1997 Resolved
Provide company procedures to master regarding vessel familiarization in accordance with STCW95 A-I/14.
Condition: Unknown
Due 21 November 1997
Resolved 21 November 1997
Documentation
Issued 26 October 1997 Resolved
Approved Shipboard Oil Pollution Emergency Plan not on board vessel as in accrodance with 33CFR151.29.
Condition: Unknown
Due 21 November 1997
Resolved 21 November 1997
Navigation
Issued 26 October 1997 Resolved
No emergency steering instructions located on the bridge in accordance with33CFR164.35(K).
Condition: Unknown
Due 21 November 1997
Resolved 21 November 1997
Navigation
Issued 26 October 1997 Resolved
No device for recording readings of echo depth sounding device in accordance with 33CFR164.35(i).
Condition: Unknown
Due 21 November 1997
Resolved 21 November 1997
Lifesaving
Issued 26 October 1997 Resolved
Inoperable alarm in meat storage locker.
Condition: Unknown
Due 21 November 1997
Resolved 21 November 1997
Documentation
Issued 26 October 1997 Resolved
Provide safety training and vessel familiarization in accordance with STCW_x001C_95 VI/1.
Condition: Unknown
Due 21 November 1997
Resolved 21 November 1997

Ownership record