MAURY USCG vessel records Sign in
← All vessels

NEW FLORIDA GIRL

NEW FLORIDA GIRL is a 1970 passenger vessel (uninspected). The Coast Guard has recorded 67 inspections since 1981, most recently in February 2017, along with 212 deficiencies — 4 with no resolution recorded — and 3 casualty investigations between 2002 and 2008.

Records from 1981 to 2017. Most recent: inspection, 16 February 2017.

Built
1970
Last inspected
16 February 2017
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDF2540
Flag
UNITED STATES
367429070 (licence lapsed)
Maury page id
psix-46666

Inspections, by type

…with no type recorded17
…past their stated due date4
Years with a record 32 calendar years (1981–2017)
The 67 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)79.7 ft × 23.6 ft × 6.1 ft
Registered tonnagegross 99 / net 67
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderA. W. COVACEVICH SHIPYARD · BILOXI MS, UNITED STATES · built 1970
Hull materialWood
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portDESTIN, FL
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Uninspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it99 - Regulatory (Subpart C or D), Gross Ton
67 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDF2540MMSI 367429070 · expired · compulsorily equipped · granted 23 October 2009, cancelled 28 December 2019
WBT2356MMSI not assigned · expired · compulsorily equipped · granted 25 June 1998, cancelled 30 August 2008
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 67

16 February 2017 Administrative Inspection · Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6088288
22 November 2016 Administrative Inspection · Examination of Repairs · Hull Examination · Internal Structural Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6045692
15 June 2016 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5910118
16 December 2015 Hull Examination · Internal Structural Exam · Administrative Inspection · Examination of Repairs
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5781337
8 December 2015 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5777271
13 December 2010 Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3903794
31 October 2008 Internal Structural Exam · Hull Examination · Examination of Repairs
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3354579
27 October 2008 Type not recorded
No type recorded · Station Destin · USCG Heartland District (CGD-H) · Activity 3352516
27 October 2008 Damage Survey
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3354350
27 October 2008 Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3354490
27 March 2007 COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2895876
1 March 2007 Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2879776
11 July 2006 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2708940
23 August 2005 Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2471858
12 January 2005 Deficiency Check · Hull Examination · Internal Structural Exam · Re-Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2305665
15 June 2004 Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2100086
20 May 2004 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2072962
9 March 2004 Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2052946
20 March 2003 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1760354
17 January 2003 Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1731527
6 August 2002 Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1658946
15 January 2002 COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1479505
23 April 2001 Deficiency Check · Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1420519
18 October 2000 Deficiency Check · Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1413825
28 January 2000 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1445648
22 July 1999 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1434917
28 January 1999 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1378517
18 October 1998 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 40796
28 May 1998 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1446660
26 November 1997 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 673818
26 November 1997 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 773845
23 October 1997 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1114906
31 July 1997 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1424486
3 July 1997 Drydock Extension · Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1447760
30 July 1996 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1090094
18 June 1996 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 885543
18 June 1996 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1404189
16 November 1995 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 882942
29 September 1995 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1422560
22 June 1995 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1419448
17 April 1995 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1461635
11 January 1995 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1169574
9 September 1994 Drydock Extension
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1176547
22 June 1994 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 860539
25 August 1993 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 848640
16 June 1993 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 841707
3 March 1993 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1150607
15 October 1992 Drydock Extension
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1256343
22 July 1992 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1267423
19 July 1991 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 942026
11 April 1991 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 934381
19 December 1990 Drydock Extension
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 910489
5 July 1990 COI Inspection · Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1234892
5 July 1989 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1039428
16 June 1989 Hull Examination · COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1201947
16 March 1988 COI Inspection · Deficiency Check · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 992971
17 March 1987 COI Inspection · Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1329766
11 September 1986 Credit Drydock
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1311829
4 April 1986 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1307612
3 April 1985 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 979373
28 March 1985 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 979372
9 April 1984 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1281340
22 September 1983 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 967402
8 April 1983 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1277941
14 September 1982 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 965083
8 April 1982 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 968830
27 April 1981 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1274965

Deficiency record · 212

Construction/Loadline › Hull › Bottom Plating
Issued 16 February 2017 No resolution recorded
Wood vessel has leaks that the owner cannot fix.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 March 2017 — due date passed with no resolution recorded
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 16 February 2017 Resolved
life jackets need to be renewed
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 March 2017
Resolved 30 March 2017
Resolution: Life jackets were renewed.
Lifesaving › Lifefloat › Float Free
Issued 16 February 2017 Resolved
Life Float need to be renewed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 March 2017
Resolved 30 March 2017
Resolution: Life float was renewed.
Construction/Loadline › Hull › Hull Plating
Issued 13 October 2016 No resolution recorded
Conduct credit drydock exam prior to carrying passenger for hire. (Vessel has hull leaks that require drydocking for repairs)
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 December 2016 — due date passed with no resolution recorded
Construction/Loadline › Hull › Hull Plating
Issued 16 June 2016 No resolution recorded
Vessel crew is required to conduct visual inspection of all internal spaces prior to getting underway and every hour while underway or anchored. Inspections are required to be logged in official log book.
Action required: 705 - Other - as specified
Due 1 January 2017 — due date passed with no resolution recorded
Engineering › Bilge Water Management System › Pump
Issued 16 June 2016 No resolution recorded
Prior to getting underway vessel crew is requireed to test and ensure proper operation of bilge system and alarms. Test is required to be logged in official log book.
Action required: 705 - Other - as specified
Due 1 January 2017 — due date passed with no resolution recorded
Construction/Loadline › Hull › Hull Plating
Issued 15 June 2016 Resolved
Vessel is required to conduct bimonthly ISE by USCG marine inspector. Next ISE is NLT 16Aug16.
Action required: 705 - Other - as specified
Due 1 January 2017
Resolved 13 October 2016
Resolution: Vessel conducted unsatisfactory ISE. Def is being cleared and new def issued to address vessel condition.
Engineering › Diesel Engine (propulsion-reduction gear) › Valve Actuating Gear
Issued 3 May 2016 Resolved
Solve the Oil Leak on the STBD Eng. Actuator
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 May 2016
Resolved 26 May 2016
Construction/Loadline › Hull › Transverse Frame
Issued 3 May 2016 Resolved
Midship Room frame 5, 6, 7 center line keel on Port side of hull leaking
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 June 2016
Resolved 26 May 2016
Resolution: Repaired.
Construction/Loadline › Hull › Transverse Frame
Issued 3 May 2016 Resolved
Port Side bracing under Steering/Transome frame leaking. Next to last frame against Transome.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 May 2016
Resolved 26 May 2016
Resolution: New fastners installed.
Engineering › Steering Gear System › Rudder Bearing
Issued 3 May 2016 Resolved
STBD Steering post re-pack and stop leak.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 May 2016
Resolved 26 May 2016
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 3 May 2016 Resolved
Install blanks for empty breakers in distribution panel.
Action required: 705 - Other - as specified
Due 10 May 2016
Resolved 26 May 2016
Resolution: installed
Documentation › Certificates/Documents › Certificate of Inspection
Issued 8 December 2015 Resolved
Vessel needs to resolve and provide receipt for User Fee's.
Condition: Invalid
Action required: 705 - Other - as specified
Due 8 January 2016
Resolved 3 May 2016
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 8 December 2015 Resolved
Provide Servicing Report for Fixed Fire System.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 January 2016
Resolved 3 May 2016
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 8 December 2015 Resolved
Provide Alcohol test equipment.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 January 2016
Resolved 3 May 2016
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 8 December 2015 Resolved
Life jacket Retro replace on 8 Jackets, and work the clips so they open easier.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 January 2016
Resolved 3 May 2016
Lifesaving › Lifebuoys › Serviceable
Issued 8 December 2015 Resolved
Replace the Life Ring Buoy with a serviciable Buoy.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 January 2016
Resolved 3 May 2016
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 8 December 2015 Resolved
Provide a First Aid kit.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 January 2016
Resolved 3 May 2016
Fire Fighting › Nozzles › Condition
Issued 8 December 2015 Resolved
Repair or replace leaking Fire hose nozzels.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 January 2016
Resolved 3 May 2016
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 8 December 2015 Resolved
Replace Fire Ext. bracket.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 January 2016
Resolved 3 May 2016
Engineering › Steering Gear System › Linkage
Issued 8 December 2015 Resolved
Prepare Steering Linkage and Tie bar for inspection.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 January 2016
Resolved 3 May 2016
Engineering › Steering Gear System › Pump
Issued 8 December 2015 Resolved
Wheel House Hydro Pump hose has a leak, repair leak.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 January 2016
Resolved 3 May 2016
Construction/Loadline › Hull › Transverse Frame
Issued 8 December 2015 Resolved
Bilge room has a leak at the CHINE on frame..
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 January 2016
Resolved 3 May 2016
Construction/Loadline › Hull › Transverse Frame
Issued 8 December 2015 Resolved
[name withheld], 2 to 3rd frame leaking, couting aft to FWD.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 January 2016
Resolved 3 May 2016
Construction/Loadline › Hull › Side Shell
Issued 8 December 2015 Resolved
Midship Rpace, frame 7 to9 leaking, counting FWD to AFT.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 January 2016
Resolved 3 May 2016
Electrical › Electrical Distribution System (service) › Wiring
Issued 8 December 2015 Resolved
Change Temporary wiring setup to Permanently installed.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 8 January 2016
Resolved 3 May 2016
Construction/Loadline › Hull › Side Shell
Issued 27 October 2008 Resolved
Vessel to complete dry-dock/internal structural exam prior to operation in a commercial capacity.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 March 2009
Resolution: Vessel has completed dry-dock and ISE.
Documentation › Certificates/Documents › Cargo Ship Safety Radio Certificate
Issued 27 March 2007 Resolved
Provide current FCC Safety Radio Certificate
Condition: Unknown
Due 30 March 2007
Resolved 14 April 2011
Construction/Loadline › Hull › Keel
Issued 1 March 2007 Resolved
Replace the wormshoe in accordance with NVIC 7-95.
Action required: 705 - Other - as specified
Due 1 April 2007
Resolved 27 March 2007
Construction/Loadline › Hull › Transverse Frame
Issued 1 March 2007 Resolved
Remove the ten rotten dead frames, five on the port and five on the starboard, and remove all the delaminated and rotting plywood decking near the shear clamp in the forepaek in accordance with NVIC 7-95.
Action required: 705 - Other - as specified
Due 1 April 2007
Resolved 27 March 2007
Construction/Loadline › Hull › Bracket
Issued 1 March 2007 Resolved
Replace the rotted butt block near frame two, from the forward bulkhead, port side in the [name withheld] in accoradance with NVIC 7-95.
Action required: 705 - Other - as specified
Due 1 April 2007
Resolved 27 March 2007
Construction/Loadline › Hull › Transverse Frame
Issued 1 March 2007 Resolved
Remove the three rotted dead frames on the port side and the four rotted dead frames on the starboard side and all of the rotting and delaminated plywood in the vicinity of the rotted dead frames in the rod room in accordance with NVIC 7-95.
Action required: 705 - Other - as specified
Due 1 April 2007
Resolved 27 March 2007
Construction/Loadline › Hull › Transverse Frame
Issued 1 March 2007 Resolved
Remove the four rotten dead frames on the starboard side in the mid ship body in accordance with NVIC 7-95.
Action required: 705 - Other - as specified
Due 1 April 2007
Resolved 27 March 2007
Construction/Loadline › Structures › Transverse Bulkhead
Issued 1 March 2007 Resolved
Make the aft watertight bulkhead in the engine room, water tight in accordance with 46 CFR 179.212.
Action required: 705 - Other - as specified
Due 1 April 2007
Resolved 27 March 2007
Construction/Loadline › Hull › Transverse Frame
Issued 1 March 2007 Resolved
Remove the two rotten dead frames near frames four and five from the forward bulkhead, starboard side of the engine room in accoradnce with NVIC 7-95.
Action required: 705 - Other - as specified
Due 1 April 2007
Resolved 27 March 2007
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 1 March 2007 Resolved
Properly secure the hand rail on the top side deck.
Action required: 705 - Other - as specified
Due 1 April 2007
Resolved 27 March 2007
Navigation › Piloting/Steering › Coast Guard Light List
Issued 11 July 2006 Resolved
Provide current copies or excerpts from navigation safety publications required by 46 CFR 184.420
Action required: 705 - Other - as specified
Due 11 August 2006
Resolved 13 July 2006
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 11 July 2006 Resolved
Closely monitor bilge level in all watertight spaces. Establish log and log inspections made by senior deckhand. Bilge inspections are to be made every 30 minuets while vessel is away from a shore side dock, has passengers on board or both. Maintain bilge levels as instructed on vessel stability letter. (46 CFR 176.800)
Action required: 705 - Other - as specified
Due 11 July 2006
Resolved 13 July 2006
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 11 July 2006 Resolved
Provide first aid kit approved in accordance with 46 CFR 160.041 (or kit with equivalent contents) as required by 46 CFR 184.710
Action required: 705 - Other - as specified
Due 11 August 2006
Resolved 13 July 2006
Lifesaving › Lifefloat › Paddle
Issued 11 July 2006 Resolved
Properly secure paddles to life floats. (46 CFR 180.200)
Action required: 17 - Rectify deficiencies prior to departure
Due 11 July 2006
Resolved 11 July 2006
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 11 July 2006 Resolved
Replace batteries in floating water lights on life floats (X 2). (46 CFR 185.726)
Action required: 17 - Rectify deficiencies prior to departure
Due 11 July 2006
Resolved 11 July 2006
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 11 July 2006 Resolved
Service portable fire extinguishers (remove rust and preserve cylinders at base) (46 CFR 176.800)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 August 2006
Resolved 13 July 2006
Engineering › Steering Gear System › Yoke
Issued 11 July 2006 Resolved
Found steering system in poor material condition. Yoke assembly attached to linier hydraulic actuator worn and loose. Overhaul yoke assembly and demonstrate proper operation of steering gear as required by 46 CFR 182.610.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 August 2006
Resolved 13 July 2006
Engineering › Diesel Engine (propulsion-reduction gear) › Crankshaft
Issued 11 July 2006 Resolved
Found port and starboard propulsion engine tachometers inoperative. Repair/renew and demonstrate proper operation of propulsion engine tachometers as required by 46 CFR 182.410
Action required: 705 - Other - as specified
Due 11 August 2006
Resolved 13 July 2006
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 11 July 2006 Resolved
Found insulation on port propulsion engine exhaust piping loose pipe exposed. Repair insulation to the satisfaction of the attending inspector. (46 CFR 176.800)
Action required: 705 - Other - as specified
Due 11 August 2006
Resolved 13 July 2006
Engineering › Fuel Oil Service System › Valve, Control
Issued 11 July 2006 Resolved
Found port fuel tank emergency shut off valve reach rod short. Extend valve to within 12 inches of deck access plate. as required by 46 CFR 182.455.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 August 2006
Resolved 13 July 2006
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 11 July 2006 Resolved
Found port propulsion engine exhaust muffler improperly supported with temporary hangers. Install permanent hangers to the satisfaction of the attending inspector. (46 CFR 182.425)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 August 2006
Resolved 13 July 2006
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 11 July 2006 Resolved
Install guard on starboard propulsion engine alternator belt drive as required by 46 CFR 177.960.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 August 2006
Resolved 13 July 2006
Electrical › Electrical Distribution System (service) › Conductor
Issued 11 July 2006 Resolved
Remove dead-ended electrical conductors/cables, improper conductor splices, install suitable cable securing devices and properly support electrical conductors and cable throughout vessel's 12 volt electrical service system, secure cable and conductor splices to suitable junction boxes throughout vessel as required by 46 CFR 183.05-50.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 August 2006
Resolved 13 July 2006
Navigation › Piloting/Steering › Marine Charts
Issued 8 March 2005 Resolved
Provide updated tide/tidal current table for area of intended operation. 46 CFR 184.420.
Action required: 705 - Other - as specified
Due 8 April 2005
Resolved 10 March 2005
Lifesaving › Hand Flares › Storage
Issued 8 March 2005 Resolved
Stow distress flares in brightly colored waterproof container marked "distress signals". 46 CFR 180.68.
Action required: 705 - Other - as specified
Due 8 April 2005
Resolved 10 March 2005
Lifesaving › Lifefloat › Approval
Issued 8 March 2005 Resolved
Provide evidence of Coast Guard approval for all life floats. 46 CFR 180.200.
Action required: 705 - Other - as specified
Due 8 April 2005
Resolved 10 March 2005
Lifesaving › Lifefloat › Pendant
Issued 8 March 2005 Resolved
Replace wasted painters & pendants on life floats. 46 CFR 180.200.
Action required: 705 - Other - as specified
Due 8 April 2005
Resolved 8 April 2005
Resolution: Cleared to the satisfaction of the attending Coast Guard Marine Inspector.
Lifesaving › Lifefloat › Float-free Link
Issued 8 March 2005 Resolved
Provide suitable weak link for buoyant apparatus. 46 CFR 180.200.
Action required: 705 - Other - as specified
Due 8 April 2005
Resolved 8 April 2005
Resolution: Cleared to the satisfaction of the attending Coast Guard Marine Inspector.
Lifesaving › Lifebuoys › Serviceable
Issued 8 March 2005 Resolved
Replace 01 ring lifebuoy, main deck portside aft. 46 CFR 180.70.
Action required: 705 - Other - as specified
Due 8 April 2005
Resolved 10 March 2005
Fire Fighting › Fixed Fire Detection System › Approval
Issued 8 March 2005 Resolved
Provide evidence of annual service of installed fixed fire detection system. 46 CFR 181.
Action required: 705 - Other - as specified
Due 8 April 2005
Resolved 10 March 2005
Fire Fighting › Fire Pumps › Impeller
Issued 8 March 2005 Resolved
Prove proper operation of fixed fire/bilge pump. 46 CFR 176.804h.
Action required: 705 - Other - as specified
Due 8 April 2005
Resolved 10 March 2005
Resolution: Corrected to the satisfaction of the attending Coast Guard Marine Inspector.
Engineering › Bilge Water Management System › Manifold
Issued 8 March 2005 Resolved
Demonstrate that bilge manifold is fully operational and that all compartments served are adequately drained. 46 CFR 182.510.
Action required: 705 - Other - as specified
Due 8 April 2005
Resolved 10 March 2005
Engineering › Bilge Water Management System › Piping
Issued 8 March 2005 Resolved
Replace wasted bilge pipe in aft steering compartment. 46 CFR 182.510.
Action required: 705 - Other - as specified
Due 8 April 2005
Resolved 10 March 2005
Fire Fighting › Remote Fuel Shutoff › General
Issued 8 March 2005 Resolved
Make port fuel oil emergency shut off valve readily accessible from main deck. 46 CFR 185.608.
Action required: 705 - Other - as specified
Due 8 April 2005
Resolved 8 April 2005
Resolution: Cleared to the satisfaction of the attending Coast Guard Marine Inspector.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 8 March 2005 Resolved
Install suitable mechanical guards on both propulsion shafts and starboard engine belt drives. 46 CFR 177.960.
Action required: 705 - Other - as specified
Due 8 April 2005
Resolved 10 March 2005
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 8 March 2005 Resolved
Install suitable blanks on 12-volt electrical panel in pilot house. 46 CFR 183.330.
Action required: 705 - Other - as specified
Due 8 April 2005
Resolved 10 March 2005
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 8 March 2005 Resolved
Replace circuit breaker for 12-volt electrical bilge pump in pilothouse 12-volt panel. 46 CFR 183.330.
Action required: 705 - Other - as specified
Due 8 April 2005
Resolved 10 March 2005
Electrical › Electrical Distribution System (service) › Wiring
Issued 8 March 2005 Resolved
Remove all dead ended electrical conductors, and properly support cables in pilothouse and machinery space. 46 CFR 183.340.
Action required: 705 - Other - as specified
Due 8 April 2005
Resolved 10 March 2005
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 12 January 2005 Resolved
De-scale port & starboard fuel oil tanks and preserve gauge top of starboard fuel oil tank, top and aft side of port tank and provide results to attending inspector.
Action required: 705 - Other - as specified
Due 12 February 2005
Resolved 8 March 2005
Construction/Loadline › Hull › Transverse Frame
Issued 12 January 2005 Resolved
Replace wasted stanchion in aft steering compartment between frames 4 and 5.
Action required: 705 - Other - as specified
Due 12 February 2005
Resolved 8 March 2005
Construction/Loadline › Hull › Bottom Plating
Issued 12 January 2005 Resolved
Refasten floor timbers 1, 3, 4, and 5 in machinery space.
Action required: 705 - Other - as specified
Due 12 February 2005
Resolved 8 March 2005
Electrical › Electric Generation Source (service) › Generator
Issued 12 January 2005 Resolved
Install metallic through hull fitting at generator cooling water overboard.
Action required: 705 - Other - as specified
Due 12 February 2005
Resolved 8 March 2005
Construction/Loadline › Penetrations › Pipe Flange
Issued 12 January 2005 Resolved
Install metallic cap on unused through hull fitting outboard of port main engine.
Action required: 705 - Other - as specified
Due 12 February 2005
Resolved 8 March 2005
Construction/Loadline › Hull › Transverse Frame
Issued 12 January 2005 Resolved
Replace vertical frame #7, port side, machinery space.
Action required: 705 - Other - as specified
Due 12 February 2005
Resolved 8 March 2005
Construction/Loadline › Hull › Transverse Frame
Issued 12 January 2005 Resolved
Clean frame fasteners at chine throughout machinery space.
Action required: 705 - Other - as specified
Due 12 February 2005
Resolved 8 March 2005
Construction/Loadline › Hull › Transverse Frame
Issued 12 January 2005 Resolved
Excavate localized decay on vertical frame ends throughout machinery space.
Action required: 705 - Other - as specified
Due 12 February 2005
Resolved 8 March 2005
Engineering › Sea-water System (primary cooling) › Valve
Issued 12 January 2005 Resolved
Replace frozen valves on starboard main engine cooling water overboard.
Action required: 705 - Other - as specified
Due 12 February 2005
Resolved 8 March 2005
Engineering › Sea-water System (primary cooling) › Piping
Issued 12 January 2005 Resolved
Replace various wasted/broken hose clamps on main engine and generator flex hose (cooling water system).
Action required: 705 - Other - as specified
Due 12 February 2005
Resolved 8 March 2005
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 12 January 2005 Resolved
Tighten sewage overboard piping, starboard holding tank.
Action required: 705 - Other - as specified
Due 12 February 2005
Resolved 8 March 2005
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 12 January 2005 Resolved
Re-caulk all seams on collision bulkhead.
Action required: 705 - Other - as specified
Due 12 February 2005
Resolved 8 March 2005
Construction/Loadline › Penetrations › Pipe Flange
Issued 12 January 2005 Resolved
Make pipe penetrations watertight on collision bulkhead, aft lower accommodation space and forward bulkhead, forward accommodation space.
Action required: 705 - Other - as specified
Due 12 February 2005
Resolved 8 March 2005
Construction/Loadline › Hull › Transverse Frame
Issued 12 January 2005 Resolved
Replace wasted stanchion in aft lower accommodation space.
Action required: 705 - Other - as specified
Due 12 February 2005
Resolved 8 March 2005
Communications › Radio Communications › EPIRB
Issued 12 January 2005 Resolved
Mount EPIRB in a suitable float free arrangement.
Action required: 705 - Other - as specified
Due 12 February 2005
Resolved 8 March 2005
Operations/Management › Drug and Alcohol Testing › MRO Specified
Issued 20 May 2004 Resolved
Provide proof of drug testing consortium is in compliance with 46 CFR 16.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2004
Resolution: Completed.
Communications › Radio Communications › EPIRB
Issued 20 May 2004 Resolved
Provide hydrostatic release for EPIRB IAW 46 CFR 185.728.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2004
Resolution: Renewed expired hydrostatic release.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Tanks
Issued 20 May 2004 Resolved
Provide weight of cylinders at servicing IAW 46 CFR 181.410.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2004
Resolution: Completed.
Accommodation/Occupational Safety › Medical/First Aid
Issued 20 May 2004 Resolved
Provide eye wash, asprins, and burn creme IAW 46 CFR 184.710. LEGACY COMPONENT DESC: Medicine Chest
Action required: 705 - Other - as specified
Due 24 June 2004
Resolved 15 June 2004
Resolution: Supplies Provided.
Fire Fighting › Fixed Fire Detection System › Heat Detectors
Issued 20 May 2004 Resolved
Provide servicing of fire detection system IAW 46 CFR 181.450.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2004
Resolution: Service completed.
Construction/Loadline › Structures
Issued 20 May 2004 Resolved
Repair leaking planks IWO lazerette IAW 46 CFR 176.420. LEGACY COMPONENT DESC: Hull planks
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2004
Resolution: Completed.
Navigation › Piloting/Steering
Issued 20 May 2004 Resolved
Provide CG light list, tides and current tables IAW 46 CFR 184.420. LEGACY COMPONENT DESC: Tide/Tidal Current Tables
Action required: 705 - Other - as specified
Due 24 June 2004
Resolved 15 June 2004
Resolution: Pubs Provided.
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 20 May 2004 Resolved
Mark upper deck "NO PASSENGERS ALLOWED" IAW 46 CFR 185.602. LEGACY COMPONENT DESC: Upper Deck
Action required: 705 - Other - as specified
Due 24 June 2004
Resolved 15 June 2004
Resolution: Marking Provided.
Navigation
Issued 15 January 2002 Resolved
Port Runing Light inoperative.
Action required: 705 - Other - as specified
Due 15 January 2002
Resolved 15 January 2002
Resolution: Owner replaced port running light bulb tested satisfactory.
Communications › Alarms/Indicators
Issued 15 January 2002 Resolved
Steering Compartment High Level alarm inoperative. LEGACY COMPONENT DESC: High Water Alarm
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 January 2002
Resolved 15 January 2002
Resolution: Owner renewed high level alarm switch, tested satisfactory.
Communications › Alarms/Indicators
Issued 15 January 2002 Resolved
Renew smoke detector battery in passenger salon. LEGACY COMPONENT DESC: Fire Alarm
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 January 2002
Resolved 15 January 2002
Resolution: Owner renewed Battery tested sat.
Construction/Loadline › Hull
Issued 6 April 2001 Resolved
REPAIR ROTTED FRAME PORT E/R 3 & 4 FRAME FORWARD OF AFT E/R BULKHEAD.
Due 15 April 2001
Resolved 15 April 2001
Resolution: ROTTED FRAME PORT E/R 3 & 4 FRAME FORWARD OF AFT E/R BULKHEAD REPAIRED.
Construction/Loadline › Hull › Hull Plating
Issued 6 April 2001 Resolved
REMOVE PLANKS PORT AND STARBOARD IDENTIFIED BY MARINE INSPECTOR FOR INSPECTION OF SECOND PLANKING.
Due 15 April 2001
Resolved 15 April 2001
Resolution: REMOVED 1 PLANK ABOVE & BELOW CHINE PORT SIDE JUST AFT OF MIDSHIP & 3 PLANKS UP FROM GARBOARD STRAKE STBD SIDE 15 FT FWD OF TRANSOM. GARBOARD STRAKE & A STRAKE STARTING FROM THE STBD STEM TO 8 FT AFT OF STEM. DAMAGED PLANKING RENEWED.
Construction/Loadline › Hull
Issued 6 April 2001 Resolved
REMOVE THROUGH BOLTS IN FORWARD PEAK FRAMES AS IDENTIFIED BY THE MARINE INSPECTOR.
Due 10 April 2001
Resolved 10 April 2001
Resolution: THROUGH BOLTS IN FORWARD PEAK REMOVED FOR INSPECTION. ALL CHINE THROUGH BOLTS WERE HOT DIPPED GALVANIZED BOLTS AND A FEW WERE NECKED DOWN DUE TO CORROSION AND WERE REPLACED.
Construction/Loadline › Hull
Issued 6 April 2001 Resolved
REMOVE FASTENERS IDENTIFIED BY THE MARINE INSPECTOR.
Due 10 April 2001
Resolved 10 April 2001
Resolution: OVER 100 FASTENERS REMOVED THROUGHOUT VESSEL. ALL WERE SILICON BRONZE AND S/S BOAT NAILS. ALL FASTENERS WERE IN GOOD SHAPE.
Construction/Loadline
Issued 18 October 2000 Resolved
REPLACE MISSING BILGE PUMP IN AFT ACCOM. SPACE.
Condition: Unknown
Due 20 October 2000
Resolved 5 December 2000
Lifesaving
Issued 18 October 2000 Resolved
RENEW HYDROSTATIC RELEASE FOR EPIRB
Condition: Unknown
Due 20 October 2000
Resolved 5 December 2000
Navigation
Issued 18 October 2000 Resolved
REPAIR MAGNETIC COMPASS LIGHT.
Condition: Unknown
Due 20 October 2000
Resolved 5 December 2000
Construction/Loadline › Hull › Bottom Plating
Issued 18 October 2000 Resolved
Repair or renew hull planking in way of port and starboard steering compartment chine as original.
Due 18 November 2000
Resolved 15 April 2001
Resolution: PLANKING IWO PORT AND STBD STEERING COMPT. CHINE BAR REPAIRED.
Engineering › Steering Gear System › Rudder
Issued 18 October 2000 Resolved
REFASTEN STEERING RUDDER POST SUPPORT BRACKETS.
Condition: Unknown
Due 18 November 2000
Resolved 15 April 2001
Resolution: STEERING RUDDER POST SUPPORT BRACKETS REFASTENED.
Construction/Loadline › Hull › Bottom Plating
Issued 18 October 2000 Resolved
REPAIR CHINE BAR AND PLANKS FWD V BERTH FRAMES 3 & 4 FROM FWD BULKHEAD.
Due 18 November 2000
Resolved 15 April 2001
Resolution: CHINE BAR AND PLANKS FWD V BERTH FRAMES 3 & 4 FROM FWD BULKHEAD ALL REPAIRED.
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 18 October 2000 Resolved
PROVIDE FIXED FIREFIGHTING PLANS APPROVED IAW 46 CFR 181.410. LEGACY COMPONENT DESC: Plans
Due 18 November 2000
Resolved 15 April 2001
Resolution: APPROVED FIXED FIREFIGHTING PLANS PROVIDED.
Construction/Loadline › Structures › Deck Plating
Issued 18 October 2000 Resolved
REPAIR DECK/OVERHEAD FWD PEAK AREA DUE TO ROT.
Condition: Unknown
Due 18 November 2000
Resolved 15 April 2001
Resolution: DECK/OVERHEAD FWD PEAK AREA REPAIRED.
Navigation
Issued 18 October 2000 Resolved
REPAIR HYDRAULIC LEAKS IN STEERING SYSTEM THROUGH-OUT
Condition: Unknown
Due 20 October 2000
Resolved 5 December 2000
Engineering
Issued 18 October 2000 Resolved
REPLACE FUEL VALVE HANDLE PORT SIDE FUEL TANK
Condition: Unknown
Due 20 October 2000
Resolved 5 December 2000
Engineering
Issued 18 October 2000 Resolved
REPAIR FUEL OIL FILTER BRACKETS.
Condition: Unknown
Due 20 October 2000
Resolved 5 December 2000
Engineering
Issued 18 October 2000 Resolved
REPAIR F/O HEADER COVER.
Condition: Unknown
Due 20 October 2000
Resolved 5 December 2000
Engineering
Issued 18 October 2000 Resolved
REPAIR FUEL OIL SHUTDOWN PORTSIDE.
Condition: Unknown
Due 20 October 2000
Resolved 5 December 2000
Accommodation/Occupational Safety › Potable Water System
Issued 18 October 2000 Resolved
MOUNT POTABLE WATER SYSTEM PUMP.
Due 18 November 2000
Resolved 15 April 2001
Resolution: POTABLE WATER SYSTEM PUMP MOUNTED.
Accommodation/Occupational Safety › Potable Water System
Issued 18 October 2000 Resolved
REFASTEN POTABLE WATER PIPING IN ENGINE ROOM.
Due 18 November 2000
Resolved 15 April 2001
Resolution: POTABLE WATER PIPING IN ENGINE ROOM REFASTENED.
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 18 October 2000 Resolved
REPAIR POTABLE WATER LEAK ON HEAD TANK.
Condition: Unknown
Action required: 705 - Other - as specified
Due 18 November 2000
Resolved 15 April 2001
Resolution: POTABLE WATER LEAK ON HEAD TANK REPAIRED..
Electrical › Electric Generation Source (service) › Generator Cable
Issued 18 October 2000 Resolved
PROVIDE CHAFFING GEAR ON GENERATOR CABLES.
Due 18 November 2000
Resolved 15 April 2001
Resolution: CHAFFING GEAR ON GENERATOR CABLES PROVIDED.
Electrical
Issued 18 October 2000 Resolved
PROVIDE SHOCK PROTECTION AND SHORT CIRCUIT PROTECTION ON KNIFE SWITCH IN BATTERY SYSTEM.
Condition: Unknown
Due 20 October 2000
Resolved 5 December 2000
Engineering
Issued 18 October 2000 Resolved
REPAIR SHAFT LEAKAGE BOTH SHAFTS.
Condition: Unknown
Due 20 October 2000
Resolved 5 December 2000
Electrical › Lighting (service)
Issued 18 October 2000 Resolved
RENEW LIGHT FIXTURE GLOBES THROUGHOUT VESSEL.
Condition: Unknown
Due 20 October 2000
Resolved 15 April 2001
Resolution: ALL LIGHT FIXTURE GLOBES THROUGHOUT VESSEL RENEWED.
Pollution Prevention/Response › Prevention Equipment
Issued 18 October 2000 Resolved
REPAIR SEWAGE PIPE LEAK STBD SEWAGE DISCHARGE. LEGACY COMPONENT DESC: Marine Sanitation Device, Type III
Condition: Unknown
Due 18 November 2000
Resolved 15 April 2001
Resolution: SEWAGE PIPE LEAK STBD SEWAGE DISCHARGE REPAIRED .
Construction/Loadline
Issued 18 October 2000 Resolved
REMOVE EXCESS OIL FROM ENGINE ROOM BILGE.
Condition: Unknown
Due 20 October 2000
Resolved 5 December 2000
Accommodation/Occupational Safety
Issued 18 October 2000 Resolved
LOCK SEWAGE VALVE OVERBOARD IN ENGINE ROOM.
Condition: Unknown
Due 20 October 2000
Resolved 5 December 2000
Engineering › Steering Gear System
Issued 18 October 2000 Resolved
RENEW STEERING MOUNT BRACKET FOR RAM.
Due 18 October 2000
Resolved 15 April 2001
Resolution: STEERING MOUNT BRACKET FOR RAM RENEWED.
Electrical › Electric Generation Source (service) › Generator Cable
Issued 18 October 2000 Resolved
RENEW GENERATOR CABLE IN ENGINE ROOM IAW 46 CFR 183.10-20 AND NEW INSTALLATION IAW 183.340.
Due 18 November 2000
Resolved 15 April 2001
Resolution: GENERATOR CABLE IN ENGINE ROOM RENEWED.
Electrical › Electrical Distribution System (service) › Wiring
Issued 18 October 2000 Resolved
REMOVE WIRE NUTS THROUGHOUT VESSEL.
Due 18 November 2000
Resolved 15 April 2001
Resolution: ALL WIRE NUTS THROUGHOUT VESSEL REMOVED.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 18 October 2000 Resolved
REPAIR EXHAUST OVERHEAD STIFFENERS. LEGACY COMPONENT DESC: Piping (exhaust)
Due 18 November 2000
Resolved 15 April 2001
Resolution: EXHAUST OVERHEAD STIFFENERS REPAIRED.
Construction/Loadline › Hull › Hull Plating
Issued 18 October 2000 Resolved
REPAIR CHINE LEAKAGE IN WAY OF ENGINE ROOM STARBOARD FRAMES 3 & 4 FROM FORWARD BULKHEAD.
Condition: Unknown
Due 18 November 2000
Resolved 15 April 2001
Resolution: CHINE LEAK REPAIRED IN WAY OF ENGINE ROOM STARBOARD FRAMES 3 & 4 FROM FORWARD BULKHEAD.
Construction/Loadline › Structures › Deck Plating
Issued 18 October 2000 Resolved
REPAIR DECK IN WAY OF TOILETS PORT AND STBD SIDE.
Due 18 November 2000
Resolved 15 April 2001
Resolution: DECK IWO TOILETS PORT AND STBD REPAIRED.
Construction/Loadline
Issued 18 October 2000 Resolved
MAKE REPAIRS TO BILGE SYSTEM AS FOLLOWS PRIOR TO CARRAGE OF PASSENGERS. REPAIR BILGE MANIFOLD VALVES. REPAIR/REPLACE ALL SUCTION STRAINERS ON ALL BILGE LINES. REPAIR/REPLACE FLOAT SWITCHES AS NEEDED. ROTATE STRAINERS ONLAZARETTE PIPING.
Condition: Unknown
Due 20 October 2000
Resolved 5 December 2000
Construction/Loadline
Issued 18 October 2000 Resolved
PROVIDE HIGH LEVEL ALARM IN LAZARETTE PRIOR TO CARRING PASSENGERS FOR HIRE.
Condition: Unknown
Due 20 October 2000
Resolved 5 December 2000
Construction/Loadline
Issued 18 October 2000 Resolved
MAKE REPAIRS TO EXCESSIVE WATER LEAKS LOCATED IN WAY OF FRAME 5 & 6/ 8 & 9 MID SHIP COMPT. PRIOR TO CARRYING PASSENGERS FOR HIRE.
Condition: Unknown
Due 20 October 2000
Resolved 5 December 2000
Navigation
Issued 18 October 2000 Resolved
REPAIR STEERING SYSTEM HYD RAM FASTENER PINS PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 20 October 2000
Resolved 5 December 2000
Engineering
Issued 18 October 2000 Resolved
REPAIR FUEL OIL LEAK ON PORT SIDE FUEL TANK VALVE STEM PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 20 October 2000
Resolved 5 December 2000
Fire Fighting
Issued 18 October 2000 Resolved
MAKE ENGINE ROOM VAPOR TIGHT IN WAY OF EXHAUST TRUNKS AND PROVIDE CLOSURE FOR VENT TRUNKS PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 20 October 2000
Resolved 5 December 2000
Construction/Loadline
Issued 18 October 2000 Resolved
REPAIR BILGE SUCTION VALVE & REACH ROD LOCATED AT THE FOREPEAK PRIOR TO CARRYING PASSENGERS FOR HIRE.
Condition: Unknown
Due 20 October 2000
Resolved 5 December 2000
Accommodation/Occupational Safety › Occupational Safety
Issued 18 October 2000 Resolved
REPAIR RAILING STANCHIONS IN WAY OF DECK PENETRATION. LEGACY COMPONENT DESC: Deck Rail
Due 18 November 2000
Resolved 15 April 2001
Resolution: RAILING STANCHIONS IN WAY OF DECK PENETRATION REPAIRED.
Construction/Loadline › Structures › Deck Plating
Issued 18 October 2000 Resolved
REPAIR HOLE IN MAINDECK CONNECTION PORTSIDE IWO 3RD FRAME AFT IN FOREPEAK._x001C_
Due 18 November 2000
Resolved 15 April 2001
Resolution: HOLE IN MAINDECK CONNECTION PORTSIDE IWO 3RD FRAME AFT IN FOREPEAK REPAIRED.
Construction/Loadline › Hull
Issued 18 October 2000 Resolved
MAKE WATERTIGHT, AREAS OF EXCESSIVE LEAKS IN FORWARD BERTH ON STARBOARD SIDE IN WAY OF 6TH FRAME AFT.
Due 18 November 2000
Resolved 15 April 2001
Resolution: AREAS OF EXCESSIVE LEAKS IN FORWARD BERTH ON STARBOARD SIDE IN WAY OF 6TH FRAME AFT MADE WATERTIGHT.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 18 October 2000 Resolved
RENEW PORT SIDE RAIL SUPPORT.
Due 18 November 2000
Resolved 15 April 2001
Resolution: PORT SIDE RAIL SUPPORT RENEWED.
Construction/Loadline › Hull
Issued 18 October 2000 Resolved
REPAIR LEAKS IN FORWARD ACCOMODATION SPACE AT ONE FRAME FORWARD OF AFT BULKHEAD ON STARBOARD SIDE.
Condition: Unknown
Due 18 November 2000
Resolved 15 April 2001
Resolution: LEAKS REPAIRED IN FORWARD ACCOMODATION SPACE AT ONE FRAME FORWARD OF AFT BULKHEAD ON STARBOARD SIDE.
Construction/Loadline › Hull
Issued 18 October 2000 Resolved
REPAIR SEEPAGE IN AFT ACCOMODATION SPACE IN WAY OF FRAMES 1, 2, & 3 FORWARD OF AFT BULKHEAD.
Due 18 November 2000
Resolved 15 April 2001
Resolution: SEEPAGE REPAIRED IN AFT ACCOMODATION SPACE IN WAY OF FRAMES 1, 2, & 3 FORWARD OF AFT BULKHEAD.
Construction/Loadline › Hull › Stiffener
Issued 18 October 2000 Resolved
REMOVE INTERIOR STIFFENERS FOR INSPECTION OF CHINE BAR THROUGH-OUT VESSEL.
Due 18 November 2000
Resolved 10 April 2001
Resolution: REMOVED INTERIOR STIFFENERS FOR INSPECTION OF CHINE BAR THROUGH-OUT VESSEL.
Construction/Loadline › Hull
Issued 18 October 2000 Resolved
REPAIR ALL BUTT BLOCKS IN ENGINE ROOM, AFT STEERING, FORWARD ACCOMODATION, & AFT ACCOMODATION SPACES. LEGACY COMPONENT DESC: Butt Blocks
Condition: Unknown
Due 18 November 2000
Resolved 15 April 2001
Resolution: ALL BUTT BLOCKS IN ENGINE ROOM, AFT STEERING, FORWARD ACCOMODATION, & AFT ACCOMODATION SPACES REPAIRED.
Construction/Loadline › Hull
Issued 18 October 2000 Resolved
REMOVE 25 FASTENERS PER SIDE OF THE VESSEL AT THE DESCRETION OF THE ATTENDING MARINE INSPECTOR, DURING DRY-DOCK
Due 18 November 2000
Resolved 10 April 2001
Resolution: REMOVED OVER 100 FASTENERS THROUGHOUT VESSEL FOR EXAMINATION.
Construction/Loadline › Penetrations › Pipe Flange
Issued 18 October 2000 Resolved
REPAIR THROUGH HULL PENETRATION PORTSIDE ENGINE ROOM RAW WATER OVERBOARD.
Due 18 November 2000
Resolved 15 April 2001
Resolution: THROUGH HULL PENETRATION PORTSIDE ENGINE ROOM RAW WATER OVERBOARD REPAIRED.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 18 October 2000 Resolved
INSTALL MACHINERY GUARDS ON BOTH MAIN DIESEL ENGINES.
Due 18 November 2000
Resolved 15 April 2001
Resolution: MACHINERY GUARDS INSTALLED ON BOTH MAIN DIESEL ENGINES.
Construction/Loadline
Issued 28 January 2000 Resolved
46 CFR 177 - RENEW KEEL BOLT IN STEERING COMPARTMENT, FRAME 8 AS DISCUSSED.
Condition: Unknown
Due 31 March 2000
Resolved 29 June 2000
Construction/Loadline
Issued 28 January 2000 Resolved
46 CFR 177 - RENEW TO ORGINAL CONDITION GUSSETTS LOCATED AT FRAMES 3, 9, AND 10 IN THE ENGINE ROOM, PORT SIDE.
Condition: Unknown
Due 31 March 2000
Resolved 29 June 2000
Construction/Loadline
Issued 28 January 2000 Resolved
46 CFR 177 - RENEW FASTENERS IN AFT BERTHING AS DISCUSSED.
Condition: Unknown
Due 31 March 2000
Resolved 29 June 2000
Construction/Loadline
Issued 28 January 2000 Resolved
VESSEL IS TO BE DRYDOCKED FOR A REQUIRED HULL EXAM NO LATER THAN 31MAR00.
Condition: Unknown
Due 31 March 2000
Resolved 29 June 2000
Lifesaving
Issued 28 May 1998 Resolved
RENEW YELLOW LINE ON LIFEFLOAT AND WATERLIGHT LINES AS PER 46 CFR 180.175
Condition: Unknown
Due 28 May 1998
Resolved 28 May 1998
Lifesaving
Issued 28 May 1998 Resolved
PROVIDE FIRST AID KIT THAT MEETS REQUIREMENTS OF 46 CFR 160.041.
Condition: Unknown
Due 28 May 1998
Resolved 28 May 1998
Navigation
Issued 28 May 1998 Resolved
MAKE NECESSARY REPAIRS TO PORT RUDDER TO STOP EXCESSIVE LEAKING
Condition: Unknown
Due 28 May 1998
Resolved 28 May 1998
Construction/Loadline
Issued 28 May 1998 Resolved
SHOW PROPER OPERATION OF FOREPEAK BILGE REMOTE OPERATED VALVE AS PER 46 CFR182.25-5(D)
Condition: Unknown
Due 28 May 1998
Resolved 28 May 1998
Documentation
Issued 28 May 1998 Resolved
PROVIDE FCC SAFETY CERTIFICATE AS PER 47 CFR 80.
Condition: Unknown
Due 28 May 1998
Resolved 28 May 1998
Navigation
Issued 28 May 1998 Resolved
PROVIDE PROPER SIZE BELL
Condition: Unknown
Due 28 May 1998
Resolved 28 May 1998
Navigation
Issued 28 May 1998 Resolved
SHOW PROPER OPERATION OF WHISTLE/HORN AS PER M16672 ANNEX III.1
Condition: Unknown
Due 28 May 1998
Resolved 28 May 1998
Documentation
Issued 26 November 1997 Resolved
VESSEL'S OWNER/OPERATOR SHALL PAY THE REQUIRED ANNUAL VESSEL INSPECTION FEE.
Condition: Unknown
Due 26 November 1997
Resolved 26 November 1997
Construction/Loadline
Issued 31 July 1997 Resolved
RECAULK SEAM BETWEEN THE 4TH PLANK AT THE PORT CORNER OF THE TRANSOM.
Condition: Unknown
Due 31 July 1997
Resolved 27 October 1997
Construction/Loadline
Issued 31 July 1997 Resolved
RECAULK PORT SIDE GARBOARD PLANK FROM THE STEM KNEE JOINT AFT APPROXIMATELY5 FEET.
Condition: Unknown
Due 31 July 1997
Resolved 27 October 1997
Construction/Loadline
Issued 31 July 1997 Resolved
CLEAN GROUNDING PLATE AND REATTACH NEW ZINCS TO THE PORT SIDE PLATE.
Condition: Unknown
Due 31 July 1997
Resolved 27 October 1997
Construction/Loadline
Issued 31 July 1997 Resolved
CLEAN GROUNDING PLATE CONNECTIONS, RE-ATTACH HULL BONDING WIRING TO THE STARBOARD GROUNDING PLATE LOCATED IT THE FORWARD ROD STORAGE COMPARTMENT.
Condition: Unknown
Due 31 July 1997
Resolved 27 October 1997
Construction/Loadline
Issued 31 July 1997 Resolved
REMOVE EPOXY FILLER, CLEAN AND DRY SEAM, RE-CAULK APPROXIMATELY 6 FEET OF THE PORT SIDE CHINE BOARD APPROXIMATELY 15 FEET FROM STERN.
Condition: Unknown
Due 31 July 1997
Resolved 27 October 1997
Construction/Loadline
Issued 31 July 1997 Resolved
REMOVE EPOXY FILLER, DRY AND RECAULK BUTT JOINT LOCATED 2 PLANKS OUTBOARD PORT SHAFT LOG.
Condition: Unknown
Due 31 July 1997
Resolved 27 October 1997
Construction/Loadline
Issued 31 July 1997 Resolved
REATTACH ALL MACHINERY GROUNDING/BONDING WIRES. CLEAN ALL INDICATIONS OF CORRISION FROM CHINE BOARD THROUGH HULL FASTENERS.
Condition: Unknown
Due 1 October 1997
Resolved 27 October 1997
Construction/Loadline
Issued 31 July 1997 Resolved
REMOVE CAULKING, DRY AND RECAULK W/COTTON BOTH SIDES OF THE BOW STEM SEAM FROM THE LOWER KNEE JOINT RISING APPROX 4 FEET.
Condition: Unknown
Due 31 July 1997
Resolved 27 October 1997
Construction/Loadline
Issued 18 June 1996 Resolved
MAKE ALL WATERTIGHT SUBDIVISION BULKHEADS WATERTIGHT, INCCCLUDING ALL CABLE, PIPING PENETRATIONS.
Condition: Unknown
Due 18 June 1996
Resolved 18 June 1996
Engineering
Issued 18 June 1996 Resolved
PROVIDE AND PROPERLY INSTALL EXHAUST BLANKETS ON STBD ENGINE EXHAUST SYSTEMAND REPAIR ALL EXHAUST PIPE LAGGING.
Condition: Unknown
Due 18 June 1996
Resolved 18 June 1996
Fire Fighting
Issued 18 June 1996 Resolved
SERVICE 15 LB CO2 FIRE EXTINGUISHER, ENSURE REQUIRE 5-YEAR HYDROSTAIC TEST IS COMPLETED.
Condition: Unknown
Due 18 June 1996
Resolved 18 June 1996
Electrical
Issued 18 June 1996 Resolved
PROVE PROPER OPERATION OF THE 110V SYSTEM AMP METER.
Condition: Unknown
Due 18 June 1996
Resolved 18 June 1996
Construction/Loadline
Issued 29 September 1995 Resolved
DRYDOCK VESSEL FOR COAST GUARD INSPECTION OF STORM DAMAGE.
Condition: Unknown
Due 29 September 1995
Resolved 29 September 1995
Construction/Loadline
Issued 29 September 1995 Resolved
REPAIR WATER LEAK ON PORT SIDE HULL PLANKS IN THIRD COMPARTMENT BETWEEN FRAMES 1 AND 2 COUNTING FROM AFT TO FORWARD.
Condition: Unknown
Due 29 September 1995
Resolved 29 September 1995
Construction/Loadline
Issued 29 September 1995 Resolved
REPAIR WATER LEAK ON PORT RUDDER BLOCK.
Condition: Unknown
Due 29 September 1995
Resolved 29 September 1995
Engineering
Issued 29 September 1995 Resolved
REPAIR WATER LEAK ON PORT MAIN ENGINE ABOVE STARTER (ENGINE BLOCK FRACTURED)
Condition: Unknown
Due 29 September 1995
Resolved 29 September 1995
Electrical
Issued 29 September 1995 Resolved
PROVIDE AND INSTALL WATER TIGHRT STUFFING TUBE ON GENERATOR 110V/220V SUPPLY CABLE.
Condition: Unknown
Due 29 September 1995
Resolved 29 September 1995
Construction/Loadline
Issued 29 September 1995 Resolved
REPAIR WATER LEAK ON STBD SIDE HULL CHINE BOARD LOCATED IN STEERRING COMPARTMENT BETWEEN FRAMES 1 AND 2 COUNTING FROM TRANSOM FORWARD.
Condition: Unknown
Due 29 September 1995
Resolved 29 September 1995
Construction/Loadline
Issued 29 September 1995 Resolved
REMOVE AND RENEW FRACTURED KEEL FROM AMIDSHIPS AFT. _x001C_ _x001C_ REPAIRS TO BE COMPLETED AS PER PROPOSAL RECIEVED 23AUG95 AND MAINTAINED IN VSL FILE.
Condition: Unknown
Due 29 September 1995
Resolved 29 September 1995
Construction/Loadline
Issued 22 June 1995 Resolved
MAKE WATERTIGHT ACCESS HATCH TO STEERING COMPARTMENT OPERABLE AND WEATHERTIGHT.
Condition: Unknown
Due 22 June 1995
Resolved 22 June 1995
Engineering
Issued 22 June 1995 Resolved
REPAIR LEAK (CRACK) ON STARBOARD ENGINE COOLING WATER SYSTEM LOCATED INBD FORWARD PART OF ENGINE.
Condition: Unknown
Due 22 June 1995
Resolved 22 June 1995
Navigation
Issued 22 June 1995 Resolved
REPACK PORT RUDDER TO REDUCE INFLOW OF WATER.
Condition: Unknown
Due 22 June 1995
Resolved 22 June 1995
Lifesaving
Issued 22 June 1995 Resolved
REPAIR CRACKS OR REPLACE PORT FORWARD LIFE RING.
Condition: Unknown
Due 22 June 1995
Resolved 22 June 1995
Fire Fighting
Issued 22 June 1995 Resolved
PROVIDE PROPER MOUNTING BRACKETS AND MOUNT 2EA. B-II FIRE EXTINGUISHERS (1 IN ENGINEROOM AND 1 IN GALLEY).
Condition: Unknown
Due 22 June 1995
Resolved 22 June 1995
Engineering
Issued 22 June 1995 Resolved
REPAIR EXHAUST LEAK ON STBD ENGINE EXHAUST SYSTEM.
Condition: Unknown
Due 22 June 1995
Resolved 22 June 1995
Engineering
Issued 16 June 1993 Resolved
PROVE OPERATION OF STARBOARD MAIN DIESEL ENGINE WATER TEMPERATURE GAGE.
Condition: Unknown
Due 16 June 1993
Resolved 16 June 1993
Fire Fighting
Issued 16 June 1993 Resolved
REMOVE FLEXIBLE HOSES FROM FIRE MAIN PIPING SYSTEM AND INSTALL RIGID PIPING.
Condition: Unknown
Due 16 June 1993
Resolved 16 June 1993
Lifesaving
Issued 16 June 1993 Resolved
MARK RING BUOY WITH VESSELS NAME.
Condition: Unknown
Due 16 June 1993
Resolved 16 June 1993
Construction/Loadline
Issued 16 June 1993 Resolved
PROVE WATERTIGHTNESS OF COLLISION BULKHEAD.
Condition: Unknown
Due 16 June 1993
Resolved 16 June 1993
Engineering
Issued 16 June 1993 Resolved
INSTALL HEAT DEFLECTOR SHIELD TO RACOR FUEL FILTER/SEPERATOR STARBOARD MAINDIESEL ENGINE
Condition: Unknown
Due 16 June 1993
Resolved 16 June 1993
Construction/Loadline
Issued 16 June 1993 Resolved
INSTALL AND PROVE OPERATION OF REACH ROD ASSEMBLY TO COLLISION BULKHEAD BILGE PIPING VALVE IN BOW COMPARTMENT.
Condition: Unknown
Due 16 June 1993
Resolved 16 June 1993
Construction/Loadline
Issued 16 June 1989 Resolved
PLACE INTERNAL COVER OVER UNUSED SHAFT LOG IN ENGINEROOM FOR FORMER CENTERLINE MAIN DIESEL.
Condition: Unknown
Due 16 June 1989
Resolved 16 June 1989
Electrical
Issued 16 June 1989 Resolved
DEMONSTRATE PROPER OPERATION OF GENERATOR.
Condition: Unknown
Due 16 June 1989
Resolved 16 June 1989
Navigation
Issued 16 June 1989 Resolved
HOOK-UP OR REMOVE AUTO PILOT AND ASSOCIATED EQUIPMENT/WIRING.
Condition: Unknown
Due 16 June 1989
Resolved 16 June 1989
Engineering
Issued 16 June 1989 Resolved
REMOVE ALL INSTRUMENTS AND WIRING TO FORMER CENTERLINE MAIN DIESEL ENGINE OR HOOK-UP AND UTILIZE AS GENERATOR INSTRUMENTS.
Condition: Unknown
Due 16 June 1989
Resolved 16 June 1989
Engineering
Issued 16 June 1989 Resolved
DEMONSTRATE OPERATION OF ALL THREE(3) 110V BILGE PUMPS.
Condition: Unknown
Due 16 June 1989
Resolved 16 June 1989
Navigation
Issued 16 June 1989 Resolved
TEST RELIEF VALVE TO SHIPS WHISTLE.
Condition: Unknown
Due 16 June 1989
Resolved 16 June 1989
Construction/Loadline
Issued 16 June 1989 Resolved
DEMONSTRATE OPERATION OF THE VESSEL WHILE UNDERWAY.
Condition: Unknown
Due 16 June 1989
Resolved 16 June 1989
Construction/Loadline
Issued 16 June 1989 Resolved
PLACE BRONZE CAP OVER UNUSED 3" ENGINE COOLING INTAKE VALVE TO FORMER CENTERLINE MAIN DIESEL.
Condition: Unknown
Due 16 June 1989
Resolved 16 June 1989
Documentation
Issued 16 June 1989 Resolved
PROVIDE ON BOARD THE VESSEL THE ORIGINAL CERTIFICATE OF DOCUMENTATION.
Condition: Unknown
Due 16 June 1989
Resolved 16 June 1989
Electrical
Issued 16 June 1989 Resolved
RENEW PORT OUTBOARD EXHAUST COVER AT HOUSE TOP (FOR GENERATOR).
Condition: Unknown
Due 16 June 1989
Resolved 16 June 1989
Engineering
Issued 16 June 1989 Resolved
PROVIDE KEYS ON CHAINS TO OPEN AFT FUEL SHUTOFF ACCESS PLATES (MOUNTS TO AFTER HOUSE BULKHEAD).
Condition: Unknown
Due 16 June 1989
Resolved 16 June 1989
Engineering
Issued 16 June 1989 Resolved
LABEL DIRECTION OFFUEL SHUTOFF VALVES-DIRECTION TO CLOSE.
Condition: Unknown
Due 16 June 1989
Resolved 16 June 1989
Unknown
Issued 16 March 1988 Resolved
PROVE PROPER OPS OF P/S PILOT HOUSE DOOR.
Condition: Unknown
Due 16 March 1988
Resolved 16 March 1988
Unknown
Issued 16 March 1988 Resolved
PROVIDE VENT DOWL FOR P/S MAINDECK VENT
Condition: Unknown
Due 16 March 1988
Resolved 16 March 1988
Unknown
Issued 16 March 1988 Resolved
PROVIDE PANEL BOX COVERS FOR DC DISTRIBUTION BOXES IN E/R AND PILOT HOUSE.
Condition: Unknown
Due 16 March 1988
Resolved 16 March 1988
Unknown
Issued 16 March 1988 Resolved
RENEW ENGINE ROOM BILGE VENT
Condition: Unknown
Due 16 March 1988
Resolved 16 March 1988
Unknown
Issued 16 March 1988 Resolved
RE-ATTACH ALL MAIN DECK LIGHTS TO DECK HOUSE
Condition: Unknown
Due 16 March 1988
Resolved 16 March 1988
Unknown
Issued 16 March 1988 Resolved
REMOVE AND TREAT DRY ROT IN ENGINE ROOM.
Condition: Unknown
Due 16 March 1988
Resolved 16 March 1988
Electrical
Issued 16 March 1988 Resolved
PROVIDE ELECTRICAL DIAGRAM OF ELECTRIC REEL RECEPTACLE INSTALLATION INCLUDING WIRE SIZES, CIRCUIT BREAKER PROTECTION AND U/L APPROVAL OF ALL OUTSIDE RECEPTACLES.
Condition: Unknown
Due 16 March 1988
Resolved 16 March 1988
Unknown
Issued 16 March 1988 Resolved
PROVIDE PROPER KEY FOR FOSO VALVE ACCESS COVERS
Condition: Unknown
Due 16 March 1988
Resolved 16 March 1988
Unknown
Issued 16 March 1988 Resolved
PROVE 30X30 MESH FLAME SCREENS FOR BOTH FOT AND MSD TANK VENTS
Condition: Unknown
Due 16 March 1988
Resolved 16 March 1988
Unknown
Issued 16 March 1988 Resolved
PROVE PROPER OPS OF 32V EMERGENCY LIGHTS SWITCHES
Condition: Unknown
Due 16 March 1988
Resolved 16 March 1988
Unknown
Issued 16 March 1988 Resolved
PROPERLY LABEL ALL CIRCUIT BREAKER SWITCHES IN ALL BREAKER BOXES
Condition: Unknown
Due 16 March 1988
Resolved 16 March 1988
Unknown
Issued 16 March 1988 Resolved
PROVE PROPER CLOSURE OF BOTH PILOT HOUSE DOORS.
Condition: Unknown
Due 16 March 1988
Resolved 16 March 1988
Unknown
Issued 16 March 1988 Resolved
TIGHTEN AND RE-PACK AS NECESSARY ALL RUDDER AND SHAFT PACKING TUBES
Condition: Unknown
Due 16 March 1988
Resolved 16 March 1988
Unknown
Issued 16 March 1988 Resolved
PLUG UNUSED THRU HULL IN LAZARETTE COMP.
Condition: Unknown
Due 16 March 1988
Resolved 16 March 1988
Unknown
Issued 16 March 1988 Resolved
PROVIDE PROPER GAUGE AND RELIEF VALVE FOR SMALL WHISTLE COMPRESSOR AND AIR RECIEVER.
Condition: Unknown
Due 16 March 1988
Resolved 16 March 1988
Navigation
Issued 17 March 1987 Resolved
REPOSITION SIDELIGHTS AFT OF MASTHEAD LIGHT IAW ANNEX I, RULE 3(B) OF 72 COLREGS.
Condition: Unknown
Due 17 March 1987
Resolved 17 March 1987

Casualty record · 3

6 August 2002Routine · role: Involved in a Marine Casualty · 1 dead · activity 1658946
9 March 2004Routine · role: Involved in a Marine Casualty · activity 2052946
27 October 2008Routine · role: Involved in a Marine Casualty · activity 3354490
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.