MAURY USCG vessel records Sign in
← All vessels

HANJIN HAIPHONG

HANJIN HAIPHONG is a 1997 freight ship. The Coast Guard has recorded 35 inspections since 1997, most recently in March 2016, along with 19 deficiencies and 4 operational controls.

Records from 1997 to 2016. Most recent: operational control imposed, 28 March 2016.

Built
1997
Last inspected
28 March 2016
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9141273 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
466663
Flag
LIBERIA
—
Maury page id
psix-466663

Inspections, by type

…with no type recorded17
Years with a record 14 calendar years (1997–2016)
The 35 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 10 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it53324 - Convention (Subpart B), Gross Ton
30816 - Convention (Subpart B), Net Ton
82496 - Displacement, Ton
62196 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 35

28 March 2016 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 5842058
19 January 2016 Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 5799331
17 November 2015 Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 5765909
11 September 2015 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5717663
18 September 2010 PII Safety Exam · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3848989
16 September 2008 Random ISPS/MTSA/PSC · Ballast Water Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3325930
4 January 2008 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3124407
15 October 2007 Random ISPS/MTSA/PSC · Ballast Water Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3080354
23 July 2007 ILO-147 Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3005339
22 July 2007 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3004386
19 March 2007 Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2890521
8 July 2006 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2705633
4 December 2005 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2545565
21 October 2005 ISPS II Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2519323
6 May 2005 Administrative Inspection
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2351177
16 October 2004 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2222256
12 October 2004 Random ISPS/MTSA/PSC
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2219529
17 July 2004 ISPS II Exam
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2136242
23 April 2004 Annual Inspection · Ballast Water Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2051080
9 November 2003 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1944441
15 August 2003 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1876465
25 May 2003 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1800666
28 February 2003 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1751009
16 February 2002 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1485731
13 February 2002 Security Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1486395
13 February 2002 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1487776
15 May 2000 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 277883
15 May 2000 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 279205
28 November 1999 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 6040
28 November 1999 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 435179
8 October 1998 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 421330
20 July 1998 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 418314
20 April 1998 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 123246
29 January 1998 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 412176
31 October 1997 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 409404

Deficiency record · 19

Lifesaving › Immersion Suits › General
Issued 11 September 2015 Resolved
An immersion suit of an appropriate size complying with the requirements of section 2.3 of the code shall be provided for every person on board the ship. All immersion suits were size XL (180-188 cm height) and many crew members are much shorter and could not don the suit due to its size. 74 SOLAS (14 cons) III/32.3.2
Action required: 705 - Other - as specified
Due 11 October 2015
Resolved 17 November 2015
Resolution: Updated the Form-B deficiency to a 17ac and had class attend in Savannah. Class sent in a class report attesting to having enough immersion suits of the appropriate size.
Engineering › Fuel Oil Service System › Pump
Issued 16 September 2008 Resolved
1400 Numerous fuel oil leaks/pools of fuel under the following machinery creating fire hazards within the engine room: Main engine fuel oil circulation pumps and Pressure pumps and visotherm heater, generator fuel oil booster pump, boiler heavy fuel oil pumps and heater adjacent to burner unit. None of these leaks were reported to the company or captain as per SMS. ISM Code A/9,10
Action required: 17 - Rectify deficiencies prior to departure
Due 17 September 2008
Resolved 17 September 2008
Resolution: Received GL Survey Statement No. 29 dated 17SEP08. All pools of fuel leakages have been cleaned up. A condition of class given to renew all cited pump shaft seals during coming voyage. C/E has sufficient spares. Ship will maintain 24 hour Fire Watch
Engineering › Lubricating Oil Service System › Piping
Issued 16 September 2008 Resolved
1400 The following lube oil leaks/pools of oil were also found in the engine room: main engine cylinder lubricators and cam shaft bearing housing and plunger hosing on cylinders 2,6,7,8,9. Ship service generator 3 rear main seal, on this leak the crew has tied down a fan to blow oil back under the generator. These leaks have not been reported to the captain as per SMS. ISM Code A/9,10
Action required: 17 - Rectify deficiencies prior to departure
Due 17 September 2008
Resolved 17 September 2008
Resolution: Received GL Survey Statement #29 dated 9/17/08. All accumulations of LO have been cleaned up. Memorandum of Class are now issued.
Construction/Loadline › Structures › Superstructure
Issued 16 September 2008 Resolved
0987 Two cracks on accommodation bulkhead found at emergency generator room at ventilation "HC2". In addition, these cracks identified on the class survey statement number 28 dated 2008-06-21 have worsened on the starboard side, and have not been reported to class as per survey report. Address to the satisfaction of class surveyor. ISM Code A/9,10
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 18 September 2008
Resolved 17 September 2008
Resolution: Received GL Class Survey Statement #29 dated 17SEP08. Cracks have been noted by class and crack stopping holes are to be drilled at crack ends. Class memorandum given.
Documentation › Logs/Records › Oil Record Book
Issued 16 September 2008 Resolved
1710 Weekly entries in the oil record book (C11.1,11.2,11.3) for the sludge and dirty oil tank capacities do not match capacities on the IOPP at least since 01May08.
Action required: 705 - Other - as specified
Due 16 September 2008
Resolved 16 September 2008
Resolution: Discussed the errors with the Captain and Chief Engineer.
Lifesaving › Rescue Boat › Hull (rigid)
Issued 16 September 2008 Resolved
0615 The rescue boat cradle appears to be damaging the rescue boat. the plastic coating protecting the fiberglass is cracked/crushed in two places on the keel and in one area on the bow. All records indicate boat is in satisfactory condition. Address corrections to the satisfaction of class. ISM Code A/9,10
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 18 September 2008
Resolved 17 September 2008
Resolution: Received GL Class Survey Statement #29 dated 17SEP08. Statutory deficiency given. Cradle to be repaired/adjusted so cradle supports rescue boat properly and eliminating contact of Boat Hull with steel structure below.
Accommodation/Occupational Safety › Refrigeration (air conditioning) › General
Issued 16 September 2008 Resolved
0320 Valve "AHV HTR REG. BY-PASS V/V" is severely leaking on the A/C system. Crew has placed a funnel with hose leading to drain in floor, as well as a 5 gallon bucket underneath to catch leaking water. the bucket was completely full, lagging underneath water logged and pools of water around the room. No reports have been made to the company. ISM Code A/9,10
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 18 September 2008
Resolved 17 September 2008
Resolution: Received GL Class Survey Statement #29 dated 17SEP08. C/E confirms that he will renew 3 valves in the system. Memorandum given to be renewed.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 16 September 2008 Resolved
1400 Main propulsion shaft seal in the engine room is leaking approximately 1 liter per day according to the Chief Engineer. No reports have been made to the company regarding the constant leak. ISM Code A/9,10
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 18 September 2008
Resolved 17 September 2008
Resolution: Received GL Class Survey Statement #29 dated 17SEP08. Leaking oil is collected. Bilges are clean. Memorandum is given. Inner shaft seal to be renewed.
Engineering › Lubricating Oil Service System › Hose
Issued 16 September 2008 Resolved
1400 the crew has modified the #8 stage of the main engine with a flexible plastic hose between the engine and a lube oil drum above the propulsion shaft due to excessive leakage. Chief Engineer states this leak was previously repaired, but continues to worsen after time. No reports have been made to the company since the repairs/re-leaks. ISM code A/9,10
Action required: 17 - Rectify deficiencies prior to departure
Due 17 September 2008
Resolved 17 September 2008
Resolution: Received GL Survey Statement No. 29 dated 17SEP08. C/E will remove hose and modify fixed hard pipe leak off piping to facilitate recycling with out compromising safety construction rules. Memorandum given for main engine piston cooling inlet.
Fire Fighting › Portable Foam Applicators › General
Issued 16 September 2008 Resolved
0720 Portable fire fighting foam onboard has not been tested since 2006 according to attached labels. No spare 20 liter container was located in the engine room.
Action required: 705 - Other - as specified
Due 16 September 2008
Resolved 16 September 2008
Resolution: Spares (new Foam) was located onboard and moved to the engine room.
Accommodation/Occupational Safety › Ventilation › General
Issued 16 September 2008 Resolved
0745 Main air supply ducting for the engine room is holed and deteriorated at the air compressor level. Intake screens for the starboard supply fan room have fallen down inside room. This could result in the inadequate prevention of the spread of fire.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 18 September 2008
Resolved 17 September 2008
Resolution: Received GL Class Survey Statement #29 dated 09SEP08. Condition of Class is given. Main engine vent ducts to be repaired or renewed. All vent plenums to be inspected and screens to be renewed.
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 16 September 2008 Resolved
Non-conductive safety matting is missing for the steering unit controller panels in the steering flat. No matting on board has records as certified non-conductive. these could cause a shock hazard to the crew.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 18 September 2008
Resolved 17 September 2008
Resolution: Received GL Class Survey Statement #29 dated 09SEP08. C/E confirms new, certified mats will be ordered. Certificate of Class given. Non-conductive safety mats to be supplied.
Engineering › Lubricating Oil Service System › Tank
Issued 16 September 2008 Resolved
1400 Bow thruster control unit and tank in the thruster space are leaking. In addition, an open pail of oil is kept beneath the tank, increasing to the oil on deck and fire hazard. No reports have been made to the captain or company.
Action required: 17 - Rectify deficiencies prior to departure
Due 18 September 2008
Resolved 18 September 2008
Resolution: Received GL Survey Statement No. 29 and GL Letter dated 17SEP08. Leaking drain valve on tank fitted with new plug. Pails of oil removed. C/E reports new filter tightened on control unit, and may have been source of leakage. No further action required.
Construction/Loadline › Structures › Door
Issued 16 September 2008 Resolved
0960 the hinged deck door directly below the engine room supply hatch on the engine control room deck level is primarily constructed of wood. this can ignite during an engine room fire and is also on an emergency escape route. steel grating may be required at this location. Address to class/flag satisfaction.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 18 September 2008
Resolved 17 September 2008
Resolution: Received GL Class Survey Statement #29 dated 09SEP08. Condition of Class given. Deck opening to be renewed of eliminated.
Engineering › Steam System (auxiliary) › Piping
Issued 15 October 2007 Resolved
Auxiliary steam line cracked. Line is located near fuel oil purifier. Cracked area is temorarily flanged. Class will certify/approve correction made to line.
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 4 January 2008
Resolution: Received Class report stating line is found in good order.
Engineering › Steering Gear System › Ram
Issued 19 March 2007 Resolved
Vessels steering gear system including the hydraulic rams, number 1 pump and hydraulic reservoir tank has an excessive amount of oil present. No documentation exists to indicate the actual condition and the Master was unaware of the issue. Address to the satisfaction of class or the issuing authority. ISM Code 10.2
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 16 April 2007
Resolution: Recieved report from Class attesting to the repairs made by the ships crew.
Fire Fighting › Firemans Outfit
Issued 13 February 2002 Resolved
PROVIDE PROPER FIRE PROOF LIFELIN ESNAP HOOK. LEGACY COMPONENT DESC: Lifeline
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 13 February 2002
Resolved 28 February 2003
Resolution: Deficiency was cleared by MSO Puget Sound on 16Feb2002. This MISLE entry updates the database to clear the deficiency from the Outstanding status.
Electrical › Electric Generation Source (emergency)
Issued 13 February 2002 Resolved
EMERGENCY GENERATOR FAILED TO START AUTOMATICALLY AND TAKE ON EMERGENCY LOAD. LEGACY COMPONENT DESC: Generator
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 13 February 2002
Resolved 28 February 2003
Resolution: Deficiency was cleared by MSO Puget Sound on 16Feb2002. This MISLE entry updates the database to clear the deficiency from the Outstanding status.
Lifesaving
Issued 31 October 1997 Resolved
MUSTER LIST AND EMERGENCY DRILLS NOT SPECIFIC TO ACTION TO BE TAKEN BY THE CREW AS PER SOLAS 74 AMENDED CHAPT. III PART C REG. 53. CORRECT PRIOR TO NEXT U.S. PORT.
Condition: Unknown
Due 3 February 1998
Resolved 3 February 1998

Ownership record