Records from 1983 to 2010. Most recent: inspection, 29 September 2010.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 53
29 September 2010
Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3859644
27 March 2009
Internal Structural Exam · MARPOL Annex VI Survey · COI Inspection · MTSA Verification · Hull Examination
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3438395
2 July 2008
Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3254979
13 March 2008
MARPOL Annex I Examination · Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3161417
16 August 2006
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2750291
31 July 2006
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2731549
6 April 2006
Re-Inspection · Hull Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2608412
22 February 2005
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2331496
20 July 2004
MTSA Verification · In-Service Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2137951
8 April 2004
Hull Examination · Internal Structural Exam · Annual Inspection
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 2030998
16 March 2004
Permit to Proceed
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2027036
5 March 2004
Administrative Inspection
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2018163
17 December 2003
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1968293
7 August 2003
In-Service Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1869105
13 February 2003
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1744211
20 August 2002
Construction Oversight
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1664000
15 April 2002
Administrative Inspection
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1604785
12 February 2002
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1486798
12 December 2001
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1436666
11 September 2001
Construction Oversight
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1389456
24 August 2001
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1429580
26 July 2001
Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1422096
1 May 2001
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1063286
26 May 2000
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1049639
17 December 1999
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 215129
29 July 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 771564
28 July 1999
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1107497
8 July 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 210712
20 May 1999
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1463477
8 September 1998
Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1469864
8 January 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1097011
6 October 1995
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1396374
30 June 1995
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1394341
27 January 1995
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 197008
27 January 1995
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 752112
13 July 1994
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 31396
2 July 1994
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 861292
6 May 1994
Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 870388
6 May 1994
Hull Examination · COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1431345
7 June 1993
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1432730
17 February 1993
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 833483
30 July 1992
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 943632
24 September 1991
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1002683
30 May 1991
Hull Examination · COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1223520
24 August 1990
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1227428
6 March 1989
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 902173
30 March 1988
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 992148
19 February 1988
Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1036076
9 March 1987
COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1018163
8 April 1986
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1297749
20 May 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1291687
28 June 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1282472
16 May 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 965576
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 13 March 2008
Resolved
Class-A boundary around galley spaces has been modified/compromised and is required to be restored to meet 46 CFR 92.07-90.
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 June 2008
Resolved 2 July 2008
Resolution: 2 fire doors and t fire screns installed
Operations/Management › Equipment Service/Testing › EPIRB
Issued 22 February 2005
Resolved
Hydrostatic release expired.
Condition: Improper/Lack of Maintenance
Due 23 February 2005
Resolved 23 February 2005
Accommodation/Occupational Safety › Sleeping Accommodations › Berth
Issued 12 December 2001
Resolved
Install rack lights for all racks in room #6.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 14 December 2001
Electrical › Electrical Distribution System (service)
Issued 12 December 2001
Resolved
Missing blank and cover for breaker box in room #6 LEGACY COMPONENT DESC: Junction Box
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 14 December 2001
Accommodation/Occupational Safety › Other Accommodation Spaces › Laundry
Issued 12 December 2001
Resolved
Install guards on the back side of the clothes dryer (cover chain and sprocket)
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 19 December 2001
Construction/Loadline › Structures
Issued 12 December 2001
Resolved
Install safety chain between railing for crane rest LEGACY COMPONENT DESC: Superstructure
Condition: Design Flaw
Action required: 705 - Other - as specified
Resolved 14 December 2001
Construction/Loadline › Structures
Issued 12 December 2001
Resolved
Replace broken window in control tower LEGACY COMPONENT DESC: Superstructure
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 14 December 2001
Lifesaving › Lifeboat
Issued 12 December 2001
Resolved
Remove excess gear surrounding rescue boat. Allow for easier access. LEGACY COMPONENT DESC: Embarkation/Disembarkation Capabilities
Action required: 705 - Other - as specified
Resolved 14 December 2001
Navigation › Collision/Grounding Avoidance
Issued 12 December 2001
Resolved
Prove/replace operation of lamp in nav light panel for forward anchor light LEGACY COMPONENT DESC: Navigation Lights
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 14 December 2001
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 12 December 2001
Resolved
Repair inoperable toilets in head for accomodations below deck.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 12 December 2001
Fire Fighting › Fixed Fire Detection System › Control Panel
Issued 12 December 2001
Resolved
Replace/prove proper operation of sensor causing system trouble alarm on fire detection panel
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 14 December 2001
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 12 December 2001
Resolved
Relocate portable FE #15 for easier access
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 14 December 2001
Electrical › Electrical Distribution System (service)
Issued 12 December 2001
Resolved
Install blanks in breaker panel located in EDG electrical room LEGACY COMPONENT DESC: Junction Box
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 14 December 2001
Engineering › Fuel Oil Service System › Hose
Issued 12 December 2001
Resolved
Renew fuel oil supply and return hoses on emergency generator.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 14 December 2001
Engineering › Fuel Oil Service System › Valve
Issued 12 December 2001
Resolved
Repair fuel oil leak at supply valve for EDG
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 14 December 2001
Engineering › Fuel Oil Service System › Valve
Issued 12 December 2001
Resolved
Repair lube oil leak at emergency generator pressure switch
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 14 December 2001
Engineering › Fuel Oil Storage/Transfer System
Issued 12 December 2001
Resolved
Install sight glass guard at emergency generator fuel day tank LEGACY COMPONENT DESC: Gauge
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 14 December 2001
Electrical › Electric Generation Source (emergency) › Power Requirement
Issued 12 December 2001
Resolved
Renew/repair battery cables located in emergency generator electrical room
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 14 December 2001
Accommodation/Occupational Safety › Occupational Safety › Spark Producing Device
Issued 12 December 2001
Resolved
Remove fuel, oil, and water from emergency generator room deck.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 14 December 2001
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 12 December 2001
Resolved
Repair ladder at kingpost for "A" frame adjacent to generator room
Condition: Design Flaw
Action required: 705 - Other - as specified
Resolved 14 December 2001
Engineering › Fuel Oil Service System › Hose
Issued 12 December 2001
Resolved
Renew lube oil hose to emergency generator pressure switch
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 14 December 2001
Accommodation/Occupational Safety › Occupational Safety › Welding/Hot Work
Issued 12 December 2001
Resolved
Renew step at main deck tntrance to warehouse.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 14 December 2001
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 12 December 2001
Resolved
Prove proper operation of oily water separator
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 14 December 2001
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 12 December 2001
Resolved
Install an approved oil content meter/bilge monitor at discharge pipe for oily water separator
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 14 December 2001
Deck/Cargo › Cargo Stowage
Issued 12 December 2001
Resolved
Designate person in charge IAW 33 CFR 155.700
Action required: 705 - Other - as specified
Resolved 14 December 2001
Accommodation/Occupational Safety › Ventilation
Issued 12 December 2001
Resolved
Renew guard on fan located between the Alco engine room and auxillary pump room
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 14 December 2001
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 12 December 2001
Resolved
Install exhaust lagging on all ship service generators and emergency generators
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 14 December 2001
Engineering › Freshwater System (jacketwater cooling)
Issued 12 December 2001
Resolved
Prove proper operation of the #3 ship service generator's radiator fan LEGACY COMPONENT DESC: Radiator fan motor
Action required: 705 - Other - as specified
Resolved 14 December 2001
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 12 December 2001
Resolved
Install brackets for generator room's fire extinguishers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 14 December 2001
Engineering › Fuel Oil Service System › Valve
Issued 12 December 2001
Resolved
Install valve handle on #1 ship service generator's fuel supply valve
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 14 December 2001
Electrical › Electric Generation Source (service) › Generator Cable
Issued 12 December 2001
Resolved
Water proof #1 ship service generator cables
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 14 December 2001
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 12 December 2001
Resolved
Renew wasted handrail stanchons at entrance to generator room
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 14 December 2001
Engineering › Diesel Engine (auxiliary) › Crankcase
Issued 12 December 2001
Resolved
Install guards on Alco flywheels
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 14 December 2001
Lifesaving
Issued 20 May 1999
Resolved
COMPLETE WORKLIST DATED 20MAY99.
Condition: Unknown
Due 20 June 1999
Resolved 29 June 1999
Lifesaving
Issued 20 May 1999
Resolved
COMPLETE WORKLIST DATED 30APR99.
Condition: Unknown
Due 15 July 1999
Resolved 28 July 1999
Lifesaving
Issued 6 May 1994
Resolved
REPLACE CHEMICAL PERSONNEL FLOTATION LIGHTS WITH SOLAS APPROVED ON (12) TWELVE PFD'S.
Condition: Unknown
Due 8 May 1994
Resolved 8 May 1994
Construction/Loadline
Issued 6 May 1994
Resolved
CROP AND RENEW SIDE HULL LONGITUDINALS #2, #3 & #4 IN COMPARTMENT A-1 COOLING WATER TANK BETWEEN FRAMES 5 THRU 11 DUE TO EXCESSIVE WASTAGE.
Condition: Unknown
Due 6 May 1994
Resolved 6 May 1994
Accommodation/Occupational Safety
Issued 7 June 1993
Resolved
PROVE PROPER OPERATION OF MARINE SANITATION DEVICE.
Condition: Unknown
Due 8 June 1993
Resolved 17 September 1993
Fire Fighting
Issued 7 June 1993
Resolved
SHOW PROPER OPERATION OF CO2 VENTILATION SHUTDOWNS AND ALARMS.
Condition: Unknown
Due 8 June 1993
Resolved 17 September 1993
Deck/Cargo
Issued 7 June 1993
Resolved
PROVIDE PROOF OF ANNUAL EXAM ON BOTH PEDISTAL CRANES.
Condition: Unknown
Due 20 August 1993
Resolved 17 September 1993
Construction/Loadline
Issued 19 February 1988
Resolved
PROPERLY INSERT ANY ACCESS HOLES IN FORWARD AND AFT DOUBLE BOTTOM TRANSVERSE BULKHEAD BELOW GALLEY AREA USED AS ACCESS TO INSTALL NEW PIPING.
Condition: Unknown
Due 19 February 1988
Resolved 19 February 1988
Construction/Loadline
Issued 19 February 1988
Resolved
CROP AND RENEW ANY INTERNAL STRUCTURAL STEEL MEMBERS THAT HAVE DETERIORATED25 PER CENT OR MORE IN FORWARD CENTER BOW RAKE COMPARTMENT.
Condition: Unknown
Due 19 February 1988
Resolved 19 February 1988
Unknown
Issued 20 May 1985
Resolved
THE FOLLOWING DEFICIENCY PERTAINS TO THE VESSEL BAR 356 DN528068
Condition: Unknown
Due 20 May 1985
Resolved 20 May 1985
Construction/Loadline
Issued 20 May 1985
Resolved
MODIFY ACCOMMENDATION SPACE IN ACCORDANCE WITH APPROVED PLANS.
Condition: Unknown
Due 20 May 1985
Resolved 20 May 1985