MAURY USCG vessel records Sign in
← All vessels

PECOS

PECOS is a 1970 industrial vessel. The Coast Guard has recorded 53 inspections since 1983, most recently in September 2010, along with 44 deficiencies.

Records from 1983 to 2010. Most recent: inspection, 29 September 2010.

Built
1970
Last inspected
29 September 2010
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8758328 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDA8357
Flag
UNITED STATES
366601790, 366762650, 369137000 (licence lapsed)
Maury page id
psix-46670

Inspections, by type

…with no type recorded12
Years with a record 26 calendar years (1983–2010)
The 53 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 16 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 1979.

Documentation record

Tonnage as PSIX records it2688 - Regulatory (Subpart C or D), Gross Ton
2709 - Convention (Subpart B), Gross Ton
2688 - Regulatory (Subpart C or D), Net Ton
812 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDA8357MMSI 369137000 · expired · compulsorily equipped · granted 20 May 2002, cancelled 21 July 2012
WCY9146MMSI 366762650 · expired · compulsorily equipped · granted 3 March 1999, cancelled 9 May 2009 · licensed under a name not among this hull’s recorded names (not shown)
WAH9129MMSI 366601790 · expired · compulsorily equipped · granted 3 June 1994, cancelled 8 August 2004 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 53

29 September 2010 Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3859644
27 March 2009 Internal Structural Exam · MARPOL Annex VI Survey · COI Inspection · MTSA Verification · Hull Examination
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3438395
2 July 2008 Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3254979
13 March 2008 MARPOL Annex I Examination · Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3161417
16 August 2006 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2750291
31 July 2006 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2731549
6 April 2006 Re-Inspection · Hull Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2608412
22 February 2005 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2331496
20 July 2004 MTSA Verification · In-Service Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2137951
8 April 2004 Hull Examination · Internal Structural Exam · Annual Inspection
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 2030998
16 March 2004 Permit to Proceed
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2027036
5 March 2004 Administrative Inspection
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2018163
17 December 2003 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1968293
7 August 2003 In-Service Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1869105
13 February 2003 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1744211
20 August 2002 Construction Oversight
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1664000
15 April 2002 Administrative Inspection
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1604785
12 February 2002 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1486798
12 December 2001 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1436666
11 September 2001 Construction Oversight
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1389456
24 August 2001 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1429580
26 July 2001 Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1422096
1 May 2001 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1063286
26 May 2000 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1049639
17 December 1999 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 215129
29 July 1999 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 771564
28 July 1999 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1107497
8 July 1999 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 210712
20 May 1999 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1463477
8 September 1998 Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1469864
8 January 1997 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1097011
6 October 1995 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1396374
30 June 1995 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1394341
27 January 1995 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 197008
27 January 1995 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 752112
13 July 1994 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 31396
2 July 1994 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 861292
6 May 1994 Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 870388
6 May 1994 Hull Examination · COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1431345
7 June 1993 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1432730
17 February 1993 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 833483
30 July 1992 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 943632
24 September 1991 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1002683
30 May 1991 Hull Examination · COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1223520
24 August 1990 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1227428
6 March 1989 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 902173
30 March 1988 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 992148
19 February 1988 Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1036076
9 March 1987 COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1018163
8 April 1986 Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1297749
20 May 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1291687
28 June 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1282472
16 May 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 965576

Deficiency record · 44

Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 13 March 2008 Resolved
Class-A boundary around galley spaces has been modified/compromised and is required to be restored to meet 46 CFR 92.07-90.
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 June 2008
Resolved 2 July 2008
Resolution: 2 fire doors and t fire screns installed
Operations/Management › Equipment Service/Testing › EPIRB
Issued 22 February 2005 Resolved
Hydrostatic release expired.
Condition: Improper/Lack of Maintenance
Due 23 February 2005
Resolved 23 February 2005
Accommodation/Occupational Safety › Sleeping Accommodations › Berth
Issued 12 December 2001 Resolved
Install rack lights for all racks in room #6.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 14 December 2001
Electrical › Electrical Distribution System (service)
Issued 12 December 2001 Resolved
Missing blank and cover for breaker box in room #6 LEGACY COMPONENT DESC: Junction Box
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 14 December 2001
Accommodation/Occupational Safety › Other Accommodation Spaces › Laundry
Issued 12 December 2001 Resolved
Install guards on the back side of the clothes dryer (cover chain and sprocket)
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 19 December 2001
Construction/Loadline › Structures
Issued 12 December 2001 Resolved
Install safety chain between railing for crane rest LEGACY COMPONENT DESC: Superstructure
Condition: Design Flaw
Action required: 705 - Other - as specified
Resolved 14 December 2001
Construction/Loadline › Structures
Issued 12 December 2001 Resolved
Replace broken window in control tower LEGACY COMPONENT DESC: Superstructure
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 14 December 2001
Lifesaving › Lifeboat
Issued 12 December 2001 Resolved
Remove excess gear surrounding rescue boat. Allow for easier access. LEGACY COMPONENT DESC: Embarkation/Disembarkation Capabilities
Action required: 705 - Other - as specified
Resolved 14 December 2001
Navigation › Collision/Grounding Avoidance
Issued 12 December 2001 Resolved
Prove/replace operation of lamp in nav light panel for forward anchor light LEGACY COMPONENT DESC: Navigation Lights
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 14 December 2001
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 12 December 2001 Resolved
Repair inoperable toilets in head for accomodations below deck.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 12 December 2001
Fire Fighting › Fixed Fire Detection System › Control Panel
Issued 12 December 2001 Resolved
Replace/prove proper operation of sensor causing system trouble alarm on fire detection panel
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 14 December 2001
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 12 December 2001 Resolved
Relocate portable FE #15 for easier access
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 14 December 2001
Electrical › Electrical Distribution System (service)
Issued 12 December 2001 Resolved
Install blanks in breaker panel located in EDG electrical room LEGACY COMPONENT DESC: Junction Box
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 14 December 2001
Engineering › Fuel Oil Service System › Hose
Issued 12 December 2001 Resolved
Renew fuel oil supply and return hoses on emergency generator.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 14 December 2001
Engineering › Fuel Oil Service System › Valve
Issued 12 December 2001 Resolved
Repair fuel oil leak at supply valve for EDG
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 14 December 2001
Engineering › Fuel Oil Service System › Valve
Issued 12 December 2001 Resolved
Repair lube oil leak at emergency generator pressure switch
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 14 December 2001
Engineering › Fuel Oil Storage/Transfer System
Issued 12 December 2001 Resolved
Install sight glass guard at emergency generator fuel day tank LEGACY COMPONENT DESC: Gauge
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 14 December 2001
Electrical › Electric Generation Source (emergency) › Power Requirement
Issued 12 December 2001 Resolved
Renew/repair battery cables located in emergency generator electrical room
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 14 December 2001
Accommodation/Occupational Safety › Occupational Safety › Spark Producing Device
Issued 12 December 2001 Resolved
Remove fuel, oil, and water from emergency generator room deck.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 14 December 2001
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 12 December 2001 Resolved
Repair ladder at kingpost for "A" frame adjacent to generator room
Condition: Design Flaw
Action required: 705 - Other - as specified
Resolved 14 December 2001
Engineering › Fuel Oil Service System › Hose
Issued 12 December 2001 Resolved
Renew lube oil hose to emergency generator pressure switch
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 14 December 2001
Accommodation/Occupational Safety › Occupational Safety › Welding/Hot Work
Issued 12 December 2001 Resolved
Renew step at main deck tntrance to warehouse.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 14 December 2001
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 12 December 2001 Resolved
Prove proper operation of oily water separator
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 14 December 2001
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 12 December 2001 Resolved
Install an approved oil content meter/bilge monitor at discharge pipe for oily water separator
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 14 December 2001
Deck/Cargo › Cargo Stowage
Issued 12 December 2001 Resolved
Designate person in charge IAW 33 CFR 155.700
Action required: 705 - Other - as specified
Resolved 14 December 2001
Accommodation/Occupational Safety › Ventilation
Issued 12 December 2001 Resolved
Renew guard on fan located between the Alco engine room and auxillary pump room
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 14 December 2001
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 12 December 2001 Resolved
Install exhaust lagging on all ship service generators and emergency generators
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 14 December 2001
Engineering › Freshwater System (jacketwater cooling)
Issued 12 December 2001 Resolved
Prove proper operation of the #3 ship service generator's radiator fan LEGACY COMPONENT DESC: Radiator fan motor
Action required: 705 - Other - as specified
Resolved 14 December 2001
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 12 December 2001 Resolved
Install brackets for generator room's fire extinguishers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 14 December 2001
Engineering › Fuel Oil Service System › Valve
Issued 12 December 2001 Resolved
Install valve handle on #1 ship service generator's fuel supply valve
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 14 December 2001
Electrical › Electric Generation Source (service) › Generator Cable
Issued 12 December 2001 Resolved
Water proof #1 ship service generator cables
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 14 December 2001
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 12 December 2001 Resolved
Renew wasted handrail stanchons at entrance to generator room
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 14 December 2001
Engineering › Diesel Engine (auxiliary) › Crankcase
Issued 12 December 2001 Resolved
Install guards on Alco flywheels
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 14 December 2001
Lifesaving
Issued 20 May 1999 Resolved
COMPLETE WORKLIST DATED 20MAY99.
Condition: Unknown
Due 20 June 1999
Resolved 29 June 1999
Lifesaving
Issued 20 May 1999 Resolved
COMPLETE WORKLIST DATED 30APR99.
Condition: Unknown
Due 15 July 1999
Resolved 28 July 1999
Lifesaving
Issued 6 May 1994 Resolved
REPLACE CHEMICAL PERSONNEL FLOTATION LIGHTS WITH SOLAS APPROVED ON (12) TWELVE PFD'S.
Condition: Unknown
Due 8 May 1994
Resolved 8 May 1994
Construction/Loadline
Issued 6 May 1994 Resolved
CROP AND RENEW SIDE HULL LONGITUDINALS #2, #3 & #4 IN COMPARTMENT A-1 COOLING WATER TANK BETWEEN FRAMES 5 THRU 11 DUE TO EXCESSIVE WASTAGE.
Condition: Unknown
Due 6 May 1994
Resolved 6 May 1994
Accommodation/Occupational Safety
Issued 7 June 1993 Resolved
PROVE PROPER OPERATION OF MARINE SANITATION DEVICE.
Condition: Unknown
Due 8 June 1993
Resolved 17 September 1993
Fire Fighting
Issued 7 June 1993 Resolved
SHOW PROPER OPERATION OF CO2 VENTILATION SHUTDOWNS AND ALARMS.
Condition: Unknown
Due 8 June 1993
Resolved 17 September 1993
Deck/Cargo
Issued 7 June 1993 Resolved
PROVIDE PROOF OF ANNUAL EXAM ON BOTH PEDISTAL CRANES.
Condition: Unknown
Due 20 August 1993
Resolved 17 September 1993
Construction/Loadline
Issued 19 February 1988 Resolved
PROPERLY INSERT ANY ACCESS HOLES IN FORWARD AND AFT DOUBLE BOTTOM TRANSVERSE BULKHEAD BELOW GALLEY AREA USED AS ACCESS TO INSTALL NEW PIPING.
Condition: Unknown
Due 19 February 1988
Resolved 19 February 1988
Construction/Loadline
Issued 19 February 1988 Resolved
CROP AND RENEW ANY INTERNAL STRUCTURAL STEEL MEMBERS THAT HAVE DETERIORATED25 PER CENT OR MORE IN FORWARD CENTER BOW RAKE COMPARTMENT.
Condition: Unknown
Due 19 February 1988
Resolved 19 February 1988
Unknown
Issued 20 May 1985 Resolved
THE FOLLOWING DEFICIENCY PERTAINS TO THE VESSEL BAR 356 DN528068
Condition: Unknown
Due 20 May 1985
Resolved 20 May 1985
Construction/Loadline
Issued 20 May 1985 Resolved
MODIFY ACCOMMENDATION SPACE IN ACCORDANCE WITH APPROVED PLANS.
Condition: Unknown
Due 20 May 1985
Resolved 20 May 1985

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.