MAURY USCG vessel records Sign in
← All vessels

JK PIONEER

JK PIONEER is a 1997 freight ship. The Coast Guard has recorded 21 inspections since 1998, most recently in September 2016, along with 12 deficiencies and 3 operational controls.

Records from 1998 to 2016. Most recent: inspection, 21 September 2016.

Built
1997
Last inspected
21 September 2016
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9131838 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
466759
Flag
SOUTH KOREA
—
Maury page id
psix-466759

Inspections, by type

…with no type recorded10
Years with a record 12 calendar years (1998–2016)
The 21 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 10 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it38775 - Convention (Subpart B), Gross Ton
24619 - Convention (Subpart B), Net Ton
72875 - Dead Weight, Ton
83831 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

GLYFADA Freight Ship · MISLE 427774 · 11 February 2001 · activity 133501

Inspection history · 21

21 September 2016 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6001342
4 January 2011 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3920398
23 March 2009 ISPS II Exam · MARPOL Annex I Examination · MARPOL Annex V Examination · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3429598
28 February 2008 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3155227
27 February 2008 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3156624
26 February 2008 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3154288
7 November 2007 Administrative Inspection
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3094995
28 February 2007 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2879208
24 February 2007 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2877084
21 February 2007 ISPS II Exam · Ballast Water Examination · MARPOL Annex I Examination · MARPOL Annex V Examination · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2874536
8 February 2006 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 2581831
9 December 2004 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2257040
6 February 2004 Ballast Water Examination · Annual Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2001909
12 January 2002 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1478085
10 January 2002 Annual Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1474441
20 February 2001 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 286868
11 February 2001 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 133501
28 February 2000 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 275063
20 April 1999 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 427663
27 July 1998 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 418439
20 January 1998 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 439406

Deficiency record · 12

Engineering › Fuel Oil Service System › Piping
Issued 21 September 2016 Resolved
1430-Auziliary Engines-The jacketed piping system shall include a means for collection of leakages and arrangements shall be provided with an alarm in case of a fuel line failure. PSCO observed that the D/G FO leak tank level alarms on #3 A/E's had been tampered with preventing their operation. SOLAS74am II-2/4.2.2.5.2 17a
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 21 September 2016
Resolved 27 September 2016
Resolution: PSC NOLA received a class report from KR satisfying the requirement.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 21 September 2016 Resolved
1745-15ppm arrgmts-Oil filtering equipment shall be provided with arrgmts to ensure that any discharge oily mixtures is automatically stopped when the oil content of the effluent exceeds 15ppm. PSCO observed a valve on the OWS piping diagram that did not include a check valve. If valve is not a check valve, oil discharge could be achieved. Provide Clarification. MARPOL Annex I/14.7 16a
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 5 October 2016
Resolved 27 September 2016
Resolution: PSC NOLA received a class report from KR satisfying the requirement.
Engineering › Diesel Engine (propulsion-direct drive) › Cylinder Head
Issued 21 September 2016 Resolved
1410-Prop Main Engine-After any survey of the ship has been completed, no change shall be made in the structural arrangements, machinery, equipment etc. PSCO observed jacket water and oil leaks on the main engine cylinder numbers four through six. SOLAS74am I/ll 16a
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 October 2016
Resolved 27 September 2016
Resolution: PSC NOLA received a class report from KR satisfying the requirement.
Fire Fighting › Fixed Fire Detection System › Detector/Call Point Grouping
Issued 21 September 2016 Resolved
0715-Detection-Fixed fire fighting and alarm systems shall be capable of immediate operation at all times. PSCO observed the smoke detector in engineers workshop was covered with a plastic cap and stuffed with rags, rendering it inoperable. SOLAS74am II-2/13.1.1 10c
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 21 September 2016
Resolved 21 September 2016
Resolution: Ships crew rectified deficiency to the satisfaction of the attending Coast Guard Marine Inspector. 10c
Navigation › Collision/Grounding Avoidance › Echo-sounding Device
Issued 4 January 2011 Resolved
The Echo Depth Sounder was reported not operational.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 February 2011
Resolved 16 March 2011
Resolution: Received, reviewed and accepted proper documentation from Japan Radio Co., Ltd. stating that the deficiency was rectified. Checks were performed which showed no signal from transducer. Transducer was replaced by dive team.
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 28 February 2007 Resolved
Vessel lost port anchor
Action required: 705 - Other - as specified
Resolved 28 February 2007
Resolution: Received satisfactory class report
Electrical › Electrical Distribution System (service)
Issued 10 January 2002 Resolved
Junction Box M-JB-1501 in Bosun Stores, under salt water pipe, not drip-tight. Make junction box safe in accordance with SOLAS 74 Amended/II-1/45. LEGACY COMPONENT DESC: Junction Box
Due 10 February 2002
Resolved 12 January 2002
Resolution: Junction box inspected, deficiency cleared.
Engineering
Issued 10 January 2002 Resolved
Overhead steam return line in way of #2 L.O. heater leaking. Crop and renew as original. SOLAS 74 Amended/II-1/26.
Due 10 February 2002
Resolved 12 January 2002
Resolution: Leaking steam return line replaced, deficiency cleared.
Documentation › Logs/Records
Issued 10 January 2002 Resolved
Communications and monthly tests not recorded in Radio (GMDSS) Log in accordance with SOLAS 74 Amended/IV/17. Properly record communications in radio log.
Due 10 February 2002
Resolved 12 January 2002
Resolution: Radio (GMDSS) Log updated, deficiency cleared.
Deck/Cargo
Issued 10 January 2002 Resolved
Closing device (dog) on starboard #3 cargo hold vent cover missing on lower forward corner. Replace same. SOLAS 74 Amended/II-1
Due 10 February 2002
Resolved 12 January 2002
Resolution: Closing dog on cargo vent replaced, deficiency cleared.
Fire Fighting › Miscellaneous Items
Issued 10 January 2002 Resolved
General service/ fire pump #2 suction gage needle missing. Repair or replace same with calibrated, fully operational gage. SOLAS 74 Amended/ II-2.
Due 10 February 2002
Resolved 12 January 2002
Resolution: Guage replaced, deficiency cleared.
Navigation
Issued 20 February 2001 Resolved
DISCOVERED MISSING NOTICE TO MARINERS(4 WEEKLY EDITIONS) FROM 1999 WHICH CONTAINED CORRECTIONS FOR CHART USED DURING TRANSIT OF PUGET SOUND. ALL OTHER CHARTS UP TO DATE. VESSEL RECIEVED SUMMARY OF CORRECTIONS ON 20FEB01AND CORRECTED CHARTS ACCORDINGLY.
Condition: Unknown
Due 23 February 2001
Resolved 23 February 2001

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.