ALPHAGAS is a 1996 tank ship. The Coast Guard has recorded 48 inspections since 1997, most recently in January 2010, along with 12 deficiencies and 11 operational controls.

Records from 1997 to 2010. Most recent: inspection, 22 January 2010.

Built
1996
Last inspected
22 January 2010
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9130456 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
466766
Flag
ANTIGUA AND BARBUDA
—
Maury page id
psix-466766

Inspections, by type

…with no type recorded24
Years with a record 9 calendar years (1997–2010)
The 48 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 16 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it1594 - Convention (Subpart B), Net Ton
1594 - Regulatory (Subpart C or D), Net Ton
4924 - Convention (Subpart B), Gross Ton
4924 - Regulatory (Subpart C or D), Gross Ton
6375 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 48

22 January 2010 Ballast Water Examination · ISPS II Exam · COC-GAS Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3668233
25 March 2004 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2031560
13 February 2004 Administrative Inspection · Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2006318
9 February 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2007374
2 February 2004 Administrative Inspection
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1999126
1 February 2004 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1998407
18 January 2004 Security Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1987527
5 January 2004 Security Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1975731
8 December 2003 Security Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1961108
24 November 2003 Security Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1953730
2 November 2003 Administrative Inspection
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1942571
8 October 2003 Deficiency Check · Administrative Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1924051
2 October 2003 Administrative Inspection
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1919563
2 October 2003 Security Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1919605
18 July 2003 Certificate of Compliance
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1850243
3 July 2003 Security Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1834503
17 June 2003 Administrative Inspection
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1819664
29 April 2003 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1782713
30 March 2003 Security Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1765229
17 March 2003 Security Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1758605
17 January 2003 Security Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1731978
4 January 2003 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1725933
6 November 2002 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1702053
15 October 2002 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1690439
9 October 2002 Administrative Inspection
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1688144
20 September 2002 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1678878
13 September 2002 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1675431
9 September 2002 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1674937
13 August 2002 Annual Inspection · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1661164
18 July 2002 Security Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1648430
8 April 2002 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1602772
8 April 2002 Security Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1604068
28 November 2001 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 295730
11 August 2001 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 292795
26 July 2001 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 292353
26 July 2001 Letter of Compliance (Initial/Renewal)
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1070056
30 April 2001 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 289368
31 October 2000 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 283690
31 October 2000 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1055413
29 September 1999 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 433247
29 September 1999 Letter of Compliance (Initial/Renewal)
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1347783
12 August 1999 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 431677
18 December 1998 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 424052
4 December 1998 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 423344
7 November 1998 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 422399
8 June 1998 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 416939
9 November 1997 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 409753
9 November 1997 Letter of Compliance (Initial/Renewal)
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1122141

Deficiency record · 12

Navigation › Piloting/Steering
Issued 2 February 2004 Resolved
Vessel required to make permanentt repairs to the gyro compass. 33 CFR 164 LEGACY COMPONENT DESC: Gyro Compass
Action required: 15 - Rectify deficiencies by next port
Resolved 13 February 2004
Resolution: Received tec report satisfying reqiuirment.
Navigation › Piloting/Steering
Issued 29 October 2003 Resolved
Vessel does not have a properly operating gyrocompass. Equipment must be fully operational prior to next U.S. port. No further requests to deviate from this requirement will be granted. LEGACY COMPONENT DESC: Gyro Compass
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 2 November 2003
Resolution: Received tech report from agent via fax dated 02NOV03 attesting to proper operation of gyrocompass.
Navigation › Piloting/Steering
Issued 8 October 2003 Resolved
Vsl was issued a Letter of Deviation to enter the Port of Corpus Christi with an inoperable gyrocompass (33 CFR 164.35(d)). LEGACY COMPONENT DESC: Gyro Compass
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 October 2003
Resolution: Received tech report dated 15OCT03 attesting to sat repairs/operation of gyrocompass.
Navigation › Piloting/Steering
Issued 1 October 2003 Resolved
Vessel does not have a properly operating gyrocompass. Equipment must be operational prior to departure next US Port. LEGACY COMPONENT DESC: Gyro Compass
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 15 October 2003
Resolution: Received tech report dated 15OCT03 attesting to sat repairs/operation of gyrocompass.
Fire Fighting › Firemans Outfit
Issued 18 July 2003 Resolved
01 chemical protective suit in paint locker needs to be replaced. SOLAS II-2 Reg 54.2.6.1 LEGACY COMPONENT DESC: Protective Clothing
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 July 2003
Resolution: Chemical suit replaced.
Navigation › Piloting/Steering
Issued 9 October 2002 Resolved
Vsl issued LOD to enter the Port of Corpus Christi with an inoperable gyrocompass with the understanding that the equipment will be operational prior to departure from port. 33 CFR 164.35 (d) LEGACY COMPONENT DESC: Gyro Compass
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 October 2002
Resolution: Rec''d copy of tech report dated 15OCT02 attesting to proper operation of gyrocompass.
Lifesaving
Issued 26 July 2001 Resolved
REPAIR/REPLACE FAULTY PORTABLE GAS (TOXIC) DETECTOR BY 02 AUGUST 2001. (IGC13.6.13)
Condition: Unknown
Due 11 August 2001
Resolved 11 August 2001
Lifesaving
Issued 31 October 2000 Resolved
Provide portable equipment capable of detection for all toxic products listed on the Certificate of Fitness.
Condition: Unknown
Due 14 November 2000
Resolved 14 November 2000
Lifesaving
Issued 31 October 2000 Resolved
Prior to next U.S. port, provide calibration curves for portable gas detection equipment, to include all products listed on the Certificate of Fitness for the span gas on board. IGC 13.6.6
Condition: Unknown
Due 14 November 2000
Resolved 14 November 2000
Lifesaving
Issued 31 October 2000 Resolved
Prior to carrying flammable cargo in U.S. waters, provide class report attesting to the proper calibration of portable gas detection equipment specific to the cargoes carried. IGC 13.6.6
Condition: Unknown
Due 14 November 2000
Resolved 14 November 2000
Deck/Cargo
Issued 7 November 1998 Resolved
Crew unable to demonstrate operation of cargo system high and low pressure alarms required by the IGC 13.4.1 (Nor was there available any evidence that the alarms had been tested recently). Vsl required to provide class report attesting to satisfactory test to USCG not later than 07DEC98.
Condition: Unknown
Due 29 December 1998
Resolved 29 December 1998
Documentation
Issued 7 November 1998 Resolved
Safety Management System (SMS) does not require that drills, fully meeting the provisions of SOLAS 74 (amended) III/18.3, be conducted. Vsl required to provide evidence from flag administration or authorized flag representative that SMS adequately addresses emergency drills.
Condition: Unknown
Due 7 December 1998
Resolved 7 December 1998

Ownership record