MAURY USCG vessel records
← All vessels

QUEEN

QUEEN is a 1970 passenger vessel (inspected). The Coast Guard has recorded 20 inspections since 2016, most recently in June 2026, along with 16 deficiencies and 1 casualty investigation in 2023.

Records from 2016 to 2026. Most recent: inspection, 15 June 2026.

Built
1970
Last inspected
15 June 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 15 June 2026
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDJ5356
Flag
UNITED STATES
Maury page id
psix-46681

Documentation record

Registered dimensions (L × B × D)48.0 ft × 15.9 ft × 2.1 ft
Registered tonnagegross 13 / net 9
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderHYDRODYNE MARINE CORP. · PORT HUENEME, CA, UNITED STATES · built 1970
Hull materialWood
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portBALBOA, CA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 16 December 2025 · expires 31 December 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it13 - Regulatory (Subpart C or D), Gross Ton
9 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 20

15 June 2026 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8332594
29 May 2025 COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8096439
6 August 2024 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7933496
9 May 2024 Deficiency Check · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7864812
28 September 2023 Administrative Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7800410
28 September 2023 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7802252
3 September 2023 Administrative Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7783854
21 June 2023 Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7629999
31 May 2022 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7422374
3 May 2022 Hull Examination · Examination of Repairs
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7442876
30 August 2021 Deficiency Check · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7300321
14 July 2021 Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7255527
29 May 2020 COI Inspection · DAPI Audit
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6966217
22 May 2020 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6961173
7 August 2019 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6705467
12 June 2018 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6414160
22 May 2018 Examination of Repairs · Hull Examination · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6383510
15 June 2017 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6160421
26 May 2016 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5876505
17 May 2016 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5855104

Deficiency record · 16

07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 9 May 2024 Resolved
All ducts shall be of rigid permanent construction of fire proof material and reasonably gastight from end to end. The ducts shall lead as direct as possible and be properly fastened and supported. Ventilation duct for engine room not properly fastened. 46CFR182.20-5(d)
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 May 2024
Resolved 14 June 2024
Resolution: New ducting installed and fitted appropriately.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 9 May 2024 Resolved
Exhaust piping shall be led to the point of escape with a minimum number of bends or elbows. It shall be gastight throughout its length and shall be properly supported by non-combustible hangers or blocks. Starboard engine exhaust piping not properly supported; chaffing is wearing away protective coating of flexible pipe. 46CFR182-15-20(a)
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 May 2024
Resolved 17 June 2024
Resolution: Owner installed new mounting system to support exhaust hose.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 September 2023 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull. Vessel lost port engine during a voyage.
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Due 2 October 2023
Resolved 2 October 2023
Resolution: conducted sat. sea trial after replacing sea water pump. All Sat.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 21 June 2023 Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided. MI identified broken light indicating water level within engine room. 46CFR182.530(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 July 2023
Resolved 19 July 2023
Resolution: New light installed. All Sat.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 21 June 2023 Resolved
A vessel must comply with the applicable requirements for any radio and Electronic Position Indicating Radiobeacon (EPIRB) installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80.MI identified missing radiotelephony certificate. 46CFR184.502
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 August 2023
Resolved 3 September 2023
Resolution: Vessel submitted satisfactory Radio Safety Certificate. All Sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 21 June 2023 Resolved
A bilge suction must be fitted with a suitable strainer having an open area not less than three times the area of the bilge pipe. MI identified missing bilge strainer in LAZ. 46CFR182.510(b)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 July 2023
Resolved 19 July 2023
Resolution: New bilge screen installed. All Sat.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 21 June 2023 Resolved
The person in command of a documented vessel must have on board a certificate of documentation currently on board. MI observed vessel did no have COD onboard. 46 CFR67.313(a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 July 2023
Resolved 19 July 2023
Resolution: COD onboard. All Sat.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 14 July 2021 Resolved
Vessels constructed of wood must provide bilge level alarms in all watertight compartments. Vessel's visual indicator for fuel tank void is inoperable. Vessel to prove proper operation of visual indicator.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 July 2021
Resolved 30 August 2021
Resolution: Vessel sent satisfactory evidence testing the alarm and panel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 7 August 2019 Resolved
Vessel found to be missing retroreflective material from lifering buoys.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 7 August 2019
Resolved 7 August 2019
Resolution: This discrepancy was corrected, to the satisfaction of the attending Marine Inspector, prior to departing the vessel.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 7 August 2019 Resolved
Vessel found to have the wrong lifejacket donning placard for the lifejackets provided on board to passengers.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 7 August 2019
Resolved 7 August 2019
Resolution: This discrepancy was corrected, to the satisfaction of the attending Marine Inspector, prior to departing the vessel.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 7 August 2019 Resolved
Vessel was missing updated light list.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 7 August 2019
Resolved 7 August 2019
Resolution: This discrepancy was corrected, to the satisfaction of the attending Marine Inspector, prior to departing the vessel.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 7 August 2019 Resolved
Vessel was missing tides and currents table on board the vessel.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 7 August 2019
Resolved 7 August 2019
Resolution: This discrepancy was corrected, to the satisfaction of the attending Marine Inspector, prior to departing the vessel.
05 - Radio Communications › N/A - No Subsystem › Distress messages: obligations and procedures
Issued 7 August 2019 Resolved
Vessel missing emergency broadcast placard.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 7 August 2019
Resolved 7 August 2019
Resolution: This discrepancy was corrected, to the satisfaction of the attending Marine Inspector, prior to departing the vessel.
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 7 August 2019 Resolved
Vessel missing EAP/distress number for crew posted on board required by DAPI.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 7 August 2019
Resolved 7 August 2019
Resolution: This discrepancy was corrected, to the satisfaction of the attending Marine Inspector, prior to departing the vessel.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 12 June 2018 Resolved
Removed 01 PFD from service.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 12 June 2018
Resolved 12 June 2018
Resolution: Lifejacket was replaced with new lifejacket.
Lifesaving › Lifebuoys › Serviceable
Issued 17 May 2016 Resolved
Renew grab line on life ring
Action required: 705 - Other - as specified
Due 31 May 2016
Resolved 26 May 2016
Resolution: Owner/operator purchased a new life ring buoy and line.

Casualty record · 1

28 September 2023Routine · role: Involved in a Marine Casualty · activity 7802252
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.