MAURY USCG vessel records Sign in
← All vessels

QUALIFIER 105

QUALIFIER 105 is a 1970 passenger vessel (inspected). The Coast Guard has recorded 117 inspections since 1985, most recently in January 2023, along with 187 deficiencies and 3 casualty investigations between 2006 and 2023.

Records from 1985 to 2023. Most recent: inspection, 19 January 2023.

Built
1970
Last inspected
19 January 2023
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDH9546
Flag
UNITED STATES
303408000, 338192000, 366033000 (licence lapsed)
Maury page id
psix-46688

Inspections, by type

…with no type recorded24
Years with a record 36 calendar years (1985–2023)
The 117 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it175 - Convention (Subpart B), Gross Ton
95 - Regulatory (Subpart C or D), Gross Ton
59 - Convention (Subpart B), Net Ton
65 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDH9546MMSI 338192000 · expired · compulsorily equipped · granted 28 April 2015, cancelled 31 May 2025
WDC5369MMSI 303408000 · expired · compulsorily equipped · granted 7 May 2005, cancelled 11 July 2015
WAJ8816MMSI 366033000 · expired · compulsorily equipped · granted 26 February 1996, cancelled 9 July 2005
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 117

19 January 2023 Type not recorded
No type recorded · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7624790
29 November 2022 Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7600949
28 February 2022 Annual Inspection · Deficiency Check · Administrative Inspection · Internal Structural Exam · In-Service Inspection · Drydock Exam · Examination of Repairs
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7403538
5 January 2022 Administrative Inspection
Administrative · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7376278
13 April 2021 Annual Inspection · Deficiency Check · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7174257
31 March 2021 Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 7166669
23 February 2021 Administrative Inspection
Administrative · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7145701
31 March 2020 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6950548
4 October 2019 In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6827940
13 March 2019 Annual Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6640366
27 February 2019 Drydock Exam · Internal Structural Exam
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 6633765
19 March 2018 COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 6374377
23 October 2017 Administrative Inspection
Administrative · Navigation Center · Activity 6292879
25 May 2017 Annual Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6307672
27 March 2017 Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6114563
23 February 2016 Annual Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 5820510
20 January 2016 Administrative Inspection
Administrative · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 5800602
9 January 2016 Liferaft Servicing
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 5824295
25 March 2014 Annual Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 4817809
30 August 2011 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4130868
19 August 2011 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4120858
11 March 2010 Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3688733
8 April 2009 MTSA Verification · Deficiency Check · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3435686
25 March 2009 Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3423759
30 July 2008 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4811186
18 April 2008 MTSA/ISPS Verification · COI Inspection · In-Service Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3184430
27 March 2008 Internal Structural Exam · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3153975
24 March 2008 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3170624
19 April 2007 COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2907488
20 February 2007 Hull Examination · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2873323
4 September 2006 Deficiency Check · Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2768828
3 September 2006 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2769572
5 June 2006 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2671344
3 May 2006 Deficiency Check · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2633082
20 March 2006 Deficiency Check · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2602923
14 February 2006 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2584946
8 February 2006 Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2581759
20 May 2005 COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2360721
20 May 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2363297
8 February 2005 Deficiency Check · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2285984
27 December 2004 Drydock Extension · Excursion Permit
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2265341
23 November 2004 Deficiency Check · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2245932
6 August 2004 Administrative Inspection
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2158246
22 July 2004 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2141732
11 June 2004 MTSA/ISPS Verification
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2095426
24 May 2004 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2077154
24 March 2004 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2030706
12 January 2004 Deficiency Check · Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1962633
2 December 2003 COI Inspection · Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1938462
11 June 2003 Administrative Inspection
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1815172
30 December 2002 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1724287
23 December 2002 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1722328
21 October 2002 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1693443
11 April 2002 Excursion Permit
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1603674
10 April 2002 Administrative Inspection
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1603358
14 January 2002 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1478553
10 January 2002 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1477321
9 January 2002 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1477224
7 December 2001 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 772853
13 July 2001 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1067448
4 January 2001 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1056637
3 January 2001 Deficiency Check · Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1399561
9 May 2000 Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1052107
14 January 2000 Hull Examination · Deadweight Survey
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1417004
26 November 1999 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1365482
2 June 1999 Excursion Permit
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 804106
8 March 1999 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1434835
26 February 1999 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 425986
14 January 1999 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1375636
5 November 1998 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 808943
3 May 1998 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1128714
6 January 1998 Re-Inspection · Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1422986
25 August 1997 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1402508
13 January 1997 COI Inspection · Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1356043
2 January 1996 COI Inspection · Deficiency Check · Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1357443
10 March 1995 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 675653
25 January 1995 COI Inspection · Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1403945
1 December 1994 Excursion Permit
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 869906
16 September 1994 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 112387
30 March 1994 Excursion Permit
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1166317
7 February 1994 Hull Examination · COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1417604
3 September 1993 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 829750
20 April 1993 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 840512
7 April 1993 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1376961
14 January 1993 Hull Examination · COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1420681
26 June 1992 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 957641
5 April 1992 Excursion Permit
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1472708
10 February 1992 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 952151
15 January 1992 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1266779
1 April 1991 Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 910459
1 April 1991 Excursion Permit
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1236644
27 March 1991 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 915462
13 December 1990 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1239151
12 June 1990 Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1221642
5 June 1990 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 927391
7 May 1990 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1237268
8 February 1990 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 930310
15 May 1989 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1194950
9 May 1989 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1199792
5 May 1989 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1279782
19 April 1989 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1037574
12 July 1988 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 897432
10 May 1988 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1348374
12 April 1988 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1044877
12 May 1987 COI Inspection · Deficiency Check · Hull Examination · Examination of Repairs
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1330818
13 January 1987 Drydock Extension
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1006233
17 November 1986 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1323555
12 August 1986 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 998576
30 May 1986 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1297520
29 April 1986 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1000528
18 April 1986 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1306424
16 April 1986 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 985220
29 January 1986 Credit Drydock
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 998137
1 November 1985 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1297048
22 April 1985 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 982896
16 April 1985 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1289211
11 April 1985 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1291936

Deficiency record · 187

01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 26 May 2022 Resolved
Renew Bridge-to-Bridge Cert 47CFR80.1001
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 June 2022
Resolved 6 June 2022
Resolution: renewed
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 26 May 2022 Resolved
Vessel required 03 life rings. Only has 02. Provide one additional life ring.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 June 2022
Resolution: 03 serviceable life rings provided
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 26 May 2022 Resolved
Ensure vessel has valid FCC Safety Radiotelephony Cert. 47CFR80.59
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 June 2022
Resolved 6 June 2022
Resolution: cert onboard
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 31 March 2021 Resolved
Void 2 - vertical keel had wastage. Provide repair plan and make approved repairs prior to credit drydock. Updated 07APR21, make permanent repairs at next drydock.
Action required: 705 - Other - as specified
Resolved 19 May 2022
Resolution: Repairs satisfactory made.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 31 March 2021 Resolved
Void 3 - Pitting IVO of keel; Provide repair plan and make approved repairs prior to credit drydock. Updated 07APR21, temp repair made, permanent repairs required at next drydock
Action required: 705 - Other - as specified
Resolved 26 May 2022
Resolution: Area was coated and will reassess at next drydock.
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 31 March 2021 Resolved
Main Deck - Repair crack in main deck IVO stbd aft corner of the house prior to credit drydock. Update 08APR21, temp repair made, permanent repair to be made in Homer, AK prior to carrying pax.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 April 2021
Resolution: repaired
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 February 2021 Resolved
Complete a satisfactory Coast Guard drydock and internal structural exam prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 April 2021
Resolution: Completed with DD-Seward MI.
Documentation › Logs/Records › Drug Test Records
Issued 8 April 2009 Resolved
Provide current proof of enrollment from drug testing consortium (Certificate of Enrollment).
Action required: 705 - Other - as specified
Due 30 April 2009
Resolved 15 April 2009
Documentation › Logs/Records › Drug Test Records
Issued 8 April 2009 Resolved
Provide drug testing MIS Report for 2008.
Action required: 705 - Other - as specified
Due 30 April 2009
Resolved 15 April 2009
Fire Fighting › Fixed Halon Fire Extinguishing System › Quantity of Halon
Issued 8 April 2009 Resolved
Refill fixed F/F system halon cylinder and test shutdowns in presence of CG inspector.
Action required: 705 - Other - as specified
Due 30 April 2009
Resolved 15 April 2009
Lifesaving › Lifeboat Equipment › Radar Transponder
Issued 8 April 2009 Resolved
Repair/replace (1) SART (radar transponder).
Action required: 705 - Other - as specified
Due 30 April 2009
Resolved 15 April 2009
Fire Fighting › Fire Pumps › Pressure
Issued 8 April 2009 Resolved
Repair/replace fire pump. Fire pump must produce 60 psi and 50 gpm.
Action required: 705 - Other - as specified
Due 30 April 2009
Resolved 15 April 2009
Construction/Loadline › Structures › Deck Plating
Issued 8 April 2009 Resolved
Crop/renew deck area above halon cylinder at next drydock in 2010.
Action required: 705 - Other - as specified
Due 30 May 2010
Resolved 30 March 2010
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 23 April 2008 Resolved
Prove recently modified Halon pressure switch installation using HOSE instead of hard pipe is acceptable per CG approved Kidde Halon design/installation manual. Install per CG approved manual.
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 April 2008
Resolved 7 May 2008
Fire Fighting › Fixed Halon Fire Extinguishing System › Quantity of Halon
Issued 23 April 2008 Resolved
Provide CG approved plans for installed E/R Halon system. COI states 125lbs of Halon, servicing report states 105lbs of Halon, and the installed Halon btl lists 103lbs of Halon.
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 April 2008
Resolved 25 April 2008
Fire Fighting › Fixed Halon Fire Extinguishing System › Piping
Issued 23 April 2008 Resolved
Ensure/provide documentation that flex hose from Halon btl to fixed piping has been hydrotested w/in past 12 years or has been installed (new) w/in past 12 years. Hoses must be hydro tested at least every 12 years.
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 April 2008
Resolved 7 May 2008
Fire Fighting › Fixed Halon Fire Extinguishing System › Quantity of Halon
Issued 23 April 2008 Resolved
Verify means to determine installed Halon btl contents are w/in acceptable limits (i.e. bottle was weighed or other acceptable methods were used during 09APR08 servicing to determine correct amount of Halon is in the btl)
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 April 2008
Resolved 25 April 2008
Resolution: blt was weighed by Simplex Grinnell on 25APR08.
Fire Fighting › Fire Hoses › Condition
Issued 18 April 2008 Resolved
Replace leaking fire hose.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 April 2008
Resolved 30 April 2008
Fire Fighting › Fire Hydrants › Condition
Issued 18 April 2008 Resolved
Prove proper operation (repair/replace) of each (2) fire hydrant valve.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 April 2008
Resolved 30 April 2008
Engineering › Fuel Oil Storage/Transfer System › Filter/Strainer
Issued 18 April 2008 Resolved
Replace holed fuel filter strainer bonnet to stbd generator.
Due 1 May 2008
Resolved 30 April 2008
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 18 April 2008 Resolved
Replace worn/chafed fuel hose on port MDE. Install chafing gear.
Due 1 May 2008
Resolved 30 April 2008
Engineering › Generator (propulsion/auxiliary-electric) › Winding
Issued 18 April 2008 Resolved
Clean excessive oil/grease from generator windings
Due 1 May 2008
Resolved 30 April 2008
Construction/Loadline › Structures › Transverse Bulkhead
Issued 18 April 2008 Resolved
In machinery space, install metallic shut off valve adjacent to thru bhd fitting to laz IAW 182.40-1
Due 1 May 2008
Resolved 30 April 2008
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 18 April 2008 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Due 1 May 2008
Resolved 30 April 2008
Documentation › Certificates/Documents › Cargo Ship Safety Radio Certificate
Issued 18 April 2008 Resolved
Provide current copy of Safety Radio Cert. Copy onboard expired May 2007.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 April 2008
Resolved 30 April 2008
Documentation › Certificates/Documents › Cargo Ship Safety Radio Certificate
Issued 18 April 2008 Resolved
Provide current Bridge-to-Bridge radio cert. Copy onboard expired May2007.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 April 2008
Resolved 30 April 2008
Communications › Radio Communications › EPIRB
Issued 18 April 2008 Resolved
Update EPIRB registration emergency contacts. Had personnel/phone number contacts who are no longer employed with company.
Due 1 May 2008
Resolved 30 April 2008
Navigation › Piloting/Steering › Marine Charts
Issued 18 April 2008 Resolved
Update Coast Pilot [name withheld], and charts.
Due 1 May 2008
Resolved 30 April 2008
Documentation › Safety Management System › Key Shipboard Operations Plans/Instructions
Issued 18 April 2008 Resolved
Provide ISM/SMS SOLAS T-boat equivalence program manual.
Due 1 May 2008
Resolved 30 April 2008
Operations/Management › Drills/Instruction › Not Conducted
Issued 18 April 2008 Resolved
Conduct and start logging fire, MOB, and abandon vsl drills.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 April 2008
Resolved 30 April 2008
Operations/Management › Equipment Service/Testing › EPIRB
Issued 18 April 2008 Resolved
Start testing monthly and logging EPIRB and SARTs.
Due 1 May 2008
Resolved 30 April 2008
Personnel › Certificates/Documents/Licenses › License, Master
Issued 18 April 2008 Resolved
Provide original licenses for master/mate and STCW training certs for crew.
Due 1 May 2008
Resolved 30 April 2008
Accommodation/Occupational Safety › Ventilation › General
Issued 18 April 2008 Resolved
Clean galley hood and oven. Remove combustibles from around oven (rags, lint, grease, etc)
Due 1 May 2008
Resolved 30 April 2008
Electrical › Lighting (emergency) › Lighting Fixture
Issued 18 April 2008 Resolved
Repair E-light, fwd berthing.
Due 1 May 2008
Resolved 18 April 2008
Fire Fighting › Miscellaneous Items › Paint/Flammable Liquid Lockers
Issued 18 April 2008 Resolved
Remove all flammables from work rm/crew berthing located in pax berthing space and properly store or remove from vsl.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 April 2008
Resolved 30 April 2008
Lifesaving › Inflatable Liferafts › Weak Link
Issued 18 April 2008 Resolved
Provide documentation that installed life raft painter weak links are correct for installation. Current weak links are for buoyant appraratus/lifefloats ([name withheld]).
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 April 2008
Resolved 30 April 2008
Resolution: new weak links provided from LR servicing company.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 18 April 2008 Resolved
Service portable fire ext in galley.
Due 1 May 2008
Resolved 30 April 2008
Operations/Management › Pollution › Retention of Oily Mixture
Issued 27 March 2008 Resolved
Remove all standing water from vessel (forepeak, bunk rooms, etc).
Action required: 705 - Other - as specified
Due 4 April 2008
Resolved 28 March 2008
Operations/Management › Pollution › Retention of Oily Mixture
Issued 27 March 2008 Resolved
Remove oily water from E/R.
Action required: 705 - Other - as specified
Due 4 April 2008
Resolved 28 March 2008
Pollution Prevention/Response › Prevention Equipment › Sewage System Valve
Issued 27 March 2008 Resolved
Remove MSD (sewage) valve for inspection.
Action required: 705 - Other - as specified
Due 27 March 2008
Resolved 28 March 2008
Fire Fighting › Structural - B Class Divisions › Windows
Issued 27 March 2008 Resolved
Repair cracked window, stbd side aft.
Action required: 705 - Other - as specified
Due 4 April 2008
Resolved 4 April 2008
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 19 April 2007 Resolved
Replace/updated 1st Aid Kit and discard all expired items.
Due 14 May 2007
Resolved 14 May 2007
Resolution: Purchased all new items for 1st Aid Kit.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 19 April 2007 Resolved
Replace battery in life-ring water-light.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 May 2007
Resolution: Installed new battery.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 20 February 2007 Resolved
Install approved Marine Sanitation Device for installed toilet in aft berthing.
Action required: 705 - Other - as specified
Due 20 March 2007
Resolved 22 March 2007
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 20 February 2007 Resolved
Properly secure all hatch covers.
Action required: 705 - Other - as specified
Due 20 March 2007
Resolved 22 March 2007
Fire Fighting › Structural - B Class Divisions › Windows
Issued 20 February 2007 Resolved
Replace aft port window in galley space.
Action required: 705 - Other - as specified
Due 20 March 2007
Resolved 22 March 2007
Fire Fighting › Fixed Halon Fire Extinguishing System › Quantity of Halon
Issued 11 September 2006 Resolved
Recharge Halon system and reinstall system by a qualified fire servicing technician.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 September 2006
Resolved 12 September 2006
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 11 September 2006 Resolved
Bolt and secure all deck fittings for sea in E/R.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 September 2006
Resolved 12 September 2006
Construction/Loadline › Hull › Bottom Plating
Issued 4 September 2006 Resolved
Repair stbd and center M/E gear boxes, fracture in lazarette (stbd), stbd rudder, and any further damage determined once vsl is hauled.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 September 2006
Resolved 11 September 2006
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 3 May 2006 Resolved
Vsl's PFDs are made of the old Kapok-style material and are no longer passable. Replace all PFDs (40 Adult, 4 Child) with new Type 1 PFDs.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 May 2006
Resolution: Purchased new adult & child PFDs.
Fire Fighting › Remote Fuel Shutoff › General
Issued 3 May 2006 Resolved
Emergency Fuel Shut-offs not properly labeled. Repaint/relabel so fuel shut-offs can be easily sighted.
Action required: 705 - Other - as specified
Resolved 17 May 2006
Resolution: Relabeled fuel shot-offs.
Personnel › Certificates/Documents/Licenses › License, Mate
Issued 3 May 2006 Resolved
Relief captain's license was not available for inspection. Present license for verification.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 May 2006
Resolution: Relief captain''s license presented for verification.
Construction/Loadline › Penetrations › Weld
Issued 3 May 2006 Resolved
A four inch weld in engine room overhead above the generators was leaking water. Repair bad weld to prevent water leak from the deck above.
Due 20 May 2006
Resolved 17 May 2006
Resolution: Cracked weld cropped and new plate inserted.
Construction/Loadline › Hull › Weld
Issued 20 March 2006 Resolved
Repair hole in the engine room over head, located amidships, aft above port generator.
Due 10 April 2006
Resolved 4 April 2006
Construction/Loadline › Hull › Weld
Issued 20 March 2006 Resolved
Repair crack in the engine overhead, located amidships, aft above starboard generator.
Due 10 April 2006
Resolved 4 April 2006
Construction/Loadline › Hull › Weld
Issued 20 March 2006 Resolved
Repair crack in the engine overhead, located above starboard main engine.
Due 10 April 2006
Resolved 4 April 2006
Construction/Loadline › Hull › Weld
Issued 20 March 2006 Resolved
Remove blue silicone in the engine room overhead, located amidships, aft above port generator.
Due 10 April 2006
Resolved 4 April 2006
Construction/Loadline › Hull › Weld
Issued 20 March 2006 Resolved
Remove lagging in the starboard side overhead, above Halon bottle and repair area where sea water is penetrating.
Due 10 April 2006
Resolved 4 April 2006
Documentation › Certificates/Documents › Certificate of Inspection
Issued 14 February 2006 Resolved
On 25Feb06, prior to carrying passengers for hire make vessel available for credit drydock.
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 March 2006
Resolved 20 March 2006
Resolution: 20 March 2006 credit drydock was given.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 20 May 2005 Resolved
Provided aspirin and burn cream for 1st aid kit.
Due 28 May 2005
Resolved 20 May 2005
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 20 May 2005 Resolved
Replace smoke detector in crew accommodation.
Due 28 May 2005
Resolved 20 May 2005
Electrical › Electric Supply System (service) › Cable
Issued 8 February 2005 Resolved
Repair shore power cable.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 16 February 2005
Resolved 16 February 2005
Stability › Watertight Integrity › General
Issued 8 February 2005 Resolved
Submit repair proposals and properly repair wastage around bilge pipes penetrating watertight bulkhead at Frame 18, stateroom J.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 25 February 2005
Resolved 24 February 2005
Resolution: Area was repaired using a 1/8" stainless steel plate over wasted area. See vessel permanent file for complete description.
Engineering › Feedwater/Condensate Water System › Valve
Issued 8 February 2005 Resolved
Replace small bait pump valve stem due to corrosion.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 February 2005
Resolved 16 February 2005
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 23 November 2004 Resolved
Properly mark adult and child PFD stowage locations.
Action required: 705 - Other - as specified
Due 30 January 2005
Resolved 3 January 2005
Resolution: Properly marked areas.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 23 November 2004 Resolved
Remove obstruction from emergency exit in the galley.
Action required: 705 - Other - as specified
Due 30 January 2005
Resolved 3 January 2005
Resolution: Removed the carpet over the emergency exit in the galley.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 23 November 2004 Resolved
Blank off open circuit in kitchen electrical panel.
Action required: 705 - Other - as specified
Due 30 January 2005
Resolved 3 January 2005
Resolution: Blanked off the open circuit.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 23 November 2004 Resolved
Place covers on electrical sockets in the engine room.
Action required: 705 - Other - as specified
Due 30 January 2005
Resolved 3 January 2005
Resolution: All electrical sockets in the engine room were covered.
Navigation › Piloting/Steering › Marine Charts
Issued 23 November 2004 Resolved
Update all charts.
Action required: 705 - Other - as specified
Due 30 January 2005
Resolved 3 January 2005
Resolution: Updated all marine charts.
Navigation › Piloting/Steering › US Coast Pilot
Issued 23 November 2004 Resolved
Update all publications.
Action required: 705 - Other - as specified
Due 30 January 2005
Resolved 3 January 2005
Resolution: Updated all publications.
Electrical › Electrical Distribution System (service)
Issued 2 December 2003 Resolved
Poperly secure wiring in fore peak overhead cable with metallic clamp. LEGACY COMPONENT DESC: Wiring
Condition: Improper Installation
Due 15 January 2004
Resolved 11 December 2003
Electrical › Lighting (service)
Issued 2 December 2003 Resolved
Provide cover for light in forepeak. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Unknown
Due 15 January 2004
Resolved 11 December 2003
Engineering › Bilge Water Management System
Issued 2 December 2003 Resolved
Remove excessive oil from bilge in engine room.
Due 15 January 2004
Resolved 11 December 2003
Fire Fighting › Remote Fuel Shutoff
Issued 2 December 2003 Resolved
Covers to fuel oil cutouts were frozen in place took approx. 30 min to free one. Owner/Operator to make them readily accessible and prove operation.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 December 2003
Engineering › Diesel Engine (propulsion-direct drive)
Issued 2 December 2003 Resolved
Port engine override was inopperable. LEGACY COMPONENT DESC: Engine Override
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 December 2003
Documentation › Logs/Records
Issued 2 December 2003 Resolved
Vessel did not have a training log or EPIRB testing log. LEGACY COMPONENT DESC: Logbook (official)
Condition: Unknown
Due 2 December 2004
Resolved 11 December 2003
Fire Fighting › Fire Hoses
Issued 2 December 2003 Resolved
Fire hose had leaks. LEGACY COMPONENT DESC: Condition
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 December 2003
Fire Fighting › Fixed Fire Detection System
Issued 2 December 2003 Resolved
Replace smoke detector in the forward part of the aft passanger accom spaces. LEGACY COMPONENT DESC: Smoke Detectors
Condition: Damaged By Earlier Event
Due 15 January 2004
Resolved 11 December 2003
Operations/Management › Drills/Instruction
Issued 2 December 2003 Resolved
Conduct man overboard, fire and abandon ship drill to satisfaction of CG marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 December 2003
Documentation › Logs/Records
Issued 2 December 2003 Resolved
Provide copy of annual drug testing report. LEGACY COMPONENT DESC: Drug Test Records
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 December 2003
Electrical › Electrical Distribution System (service)
Issued 21 October 2002 Resolved
Repack cables on Rudder Angle Indicator in Lazarette. LEGACY COMPONENT DESC: Cable
Condition: Improper/Lack of Maintenance
Due 26 December 2002
Resolved 23 December 2002
Electrical › Electrical Distribution System (service)
Issued 21 October 2002 Resolved
Install metallic cable clamps on cable runs in the ER. LEGACY COMPONENT DESC: Wiring
Condition: Improper Installation
Due 26 December 2002
Resolved 23 December 2002
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 21 October 2002 Resolved
Renew exhaust lagging on center MDE piping. LEGACY COMPONENT DESC: Piping (exhaust)
Condition: Improper/Lack of Maintenance
Due 26 December 2002
Resolved 23 December 2002
Accommodation/Occupational Safety › Potable Water System
Issued 21 October 2002 Resolved
Install BLKHD mounting strap to hot water heater and mount to BLKHD. LEGACY COMPONENT DESC: Hot water heater
Condition: Improper Installation
Due 26 December 2002
Resolved 23 December 2002
Accommodation/Occupational Safety › Occupational Safety
Issued 21 October 2002 Resolved
Enclose exposed OVHD in food preparation area. LEGACY COMPONENT DESC: Guards for Exposed Hazards
Condition: Damaged By Earlier Event
Due 26 December 2002
Resolved 23 December 2002
Accommodation/Occupational Safety › Occupational Safety
Issued 21 October 2002 Resolved
Submit 2692 explaining smoke and fire damage in food preparation area in galley. LEGACY COMPONENT DESC: Guards for Exposed Hazards
Condition: Damaged By Earlier Event
Due 26 December 2002
Resolved 23 December 2002
Deck/Cargo › Holds/Tanks
Issued 21 October 2002 Resolved
Install capture chains on all flush deck hatches LEGACY COMPONENT DESC: Hatch Cover
Condition: Improper/Lack of Maintenance
Due 26 December 2002
Resolved 23 December 2002
Accommodation/Occupational Safety › Occupational Safety
Issued 21 October 2002 Resolved
Label and provide access to emergency escape hatches LEGACY COMPONENT DESC: Escape Hatches
Condition: Improper Installation
Due 26 December 2002
Resolved 23 December 2002
Navigation › Electronic Positioning
Issued 21 October 2002 Resolved
Renew batteries in EPIRB LEGACY COMPONENT DESC: EPIRB
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 November 2002
Construction/Loadline › Structures
Issued 13 December 2001 Resolved
Repair/reweld/replace fractured deck, superstructure, through hull fittings as indicated by the ABS inspector to the satisfaction of both the ABS and USCG inspectors. LEGACY COMPONENT DESC: Superstructure
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 15 January 2002
Resolved 21 December 2001
Engineering › Diesel Engine (auxiliary)
Issued 13 December 2001 Resolved
Free up the actuation of the STBD SSDG raw water valve for inspection. LEGACY COMPONENT DESC: Valve
Condition: Improper/Lack of Maintenance
Due 15 January 2002
Resolved 13 December 2001
Lifesaving
Issued 7 December 2001 Resolved
Provide proof of liferaft servicing completion and call for CG Inspection.
Condition: Unknown
Due 7 December 2001
Resolved 7 December 2001
Accommodation/Occupational Safety
Issued 7 December 2001 Resolved
Provide guards or diffusers for open lights in galley, crew & passenger berthing.
Condition: Unknown
Due 10 January 2002
Resolved 10 January 2002
Electrical
Issued 7 December 2001 Resolved
Mark circuit breakers in pilot house port side panel.
Condition: Unknown
Due 7 December 2001
Resolved 7 December 2001
Accommodation/Occupational Safety
Issued 7 December 2001 Resolved
Provide blade guards for galley ventullation fan.
Condition: Unknown
Due 10 January 2002
Resolved 10 January 2002
Accommodation/Occupational Safety
Issued 7 December 2001 Resolved
Provide proper vent for MSD tank W30X30 mesh screen.
Condition: Unknown
Due 10 January 2002
Resolved 10 January 2002
Fire Fighting
Issued 7 December 2001 Resolved
Arrange for CG inspectors to witness fixed fire supression tests.
Condition: Unknown
Due 10 January 2002
Resolved 10 January 2002
Accommodation/Occupational Safety
Issued 7 December 2001 Resolved
Secure ceiling in the galley.
Condition: Unknown
Due 10 January 2002
Resolved 10 January 2002
Electrical
Issued 7 December 2001 Resolved
Rehang wires in FWD berthing with metal hangers.
Condition: Unknown
Due 7 December 2001
Resolved 7 December 2001
Electrical
Issued 7 December 2001 Resolved
Remove unused wires in JCT box in lazerette.
Condition: Unknown
Due 7 December 2001
Resolved 7 December 2001
Electrical
Issued 7 December 2001 Resolved
Cover blank spaces in breaker box in aft engineroom.
Condition: Unknown
Due 7 December 2001
Resolved 7 December 2001
Electrical
Issued 7 December 2001 Resolved
Remove unused electrical cables over STBD generator and FWD of STBD MDE.
Condition: Unknown
Due 7 December 2001
Resolved 7 December 2001
Engineering
Issued 7 December 2001 Resolved
Secure MORSE cables W metallic hangers in the ER.
Condition: Unknown
Due 10 January 2002
Resolved 10 January 2002
Engineering
Issued 7 December 2001 Resolved
Label emergency fuel cutoff valves to indicate direction of operation.
Condition: Unknown
Due 10 January 2002
Resolved 10 January 2002
Engineering
Issued 7 December 2001 Resolved
Provide proper flame screen on STBD aft fuel tank vent.
Condition: Unknown
Due 10 January 2002
Resolved 10 January 2002
Electrical › Electrical Distribution System (service)
Issued 7 December 2001 Resolved
Mark circuit breakers in PH panel, port side. LEGACY COMPONENT DESC: Panelboard
Condition: Improper/Lack of Maintenance
Due 15 January 2002
Resolved 10 January 2002
Electrical › Electrical Distribution System (service)
Issued 7 December 2001 Resolved
Rehang electrical cables in FWD berthing with metallic hangers. LEGACY COMPONENT DESC: Cable
Condition: Improper/Lack of Maintenance
Due 15 January 2002
Resolved 10 January 2002
Electrical › Electrical Distribution System (service)
Issued 7 December 2001 Resolved
Remove unused cable in JCT box, port side lazarette. LEGACY COMPONENT DESC: Cable
Condition: Improper/Lack of Maintenance
Due 15 January 2002
Resolved 10 January 2002
Electrical › Electrical Distribution System (service)
Issued 7 December 2001 Resolved
Cover blank spaces in BRKR box in aft ER. LEGACY COMPONENT DESC: Panelboard
Condition: Improper/Lack of Maintenance
Due 15 January 2002
Resolved 10 January 2002
Electrical › Electrical Distribution System (service)
Issued 7 December 2001 Resolved
remove unuised cables over STBD SSDG an FWD of STBD MDE. LEGACY COMPONENT DESC: Cable
Condition: Improper/Lack of Maintenance
Due 15 January 2002
Resolved 10 January 2002
Engineering › Diesel Engine (propulsion-direct drive)
Issued 7 December 2001 Resolved
secure morse cables with metallic hangers LEGACY COMPONENT DESC: Morse cable
Condition: Improper Installation
Due 15 January 2002
Resolved 10 January 2002
Engineering › Fuel Oil Storage/Transfer System
Issued 7 December 2001 Resolved
label emergency fuel cut-offs in Er to indicate direction of operation. LEGACY COMPONENT DESC: Valve
Condition: Improper/Lack of Maintenance
Due 15 January 2002
Resolved 16 January 2002
Engineering › Fuel Oil Storage/Transfer System
Issued 7 December 2001 Resolved
Provide proper vent screen for STBD aft fuel vent. LEGACY COMPONENT DESC: Vent Pipe
Condition: Improper/Lack of Maintenance
Due 15 January 2002
Resolved 10 January 2002
Accommodation/Occupational Safety › Washroom/Toilet
Issued 7 December 2001 Resolved
Provide proper vent for MSD tank with 30X30 mesh screen. LEGACY COMPONENT DESC: Toilet
Condition: Improper/Lack of Maintenance
Due 15 January 2002
Resolved 10 January 2002
Accommodation/Occupational Safety › Sleeping Accommodations
Issued 7 December 2001 Resolved
place guards or diffusers on lights in upper deck berthing, galley lights and galley alcove lights. LEGACY COMPONENT DESC: Berth
Condition: Improper/Lack of Maintenance
Due 15 January 2002
Resolved 10 January 2002
Accommodation/Occupational Safety › Messroom
Issued 7 December 2001 Resolved
place blade guards on galley fan. LEGACY COMPONENT DESC: Location
Condition: Improper/Lack of Maintenance
Due 15 January 2002
Resolved 10 January 2002
Resolution: Fan removed
Accommodation/Occupational Safety › Messroom
Issued 7 December 2001 Resolved
Secure wood ceiling in galley. LEGACY COMPONENT DESC: Location
Condition: Improper/Lack of Maintenance
Due 15 January 2002
Resolved 10 January 2002
Resolution: Fan removed
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 7 December 2001 Resolved
Arrange for CG inspectors to be present for fire suppression tests. LEGACY COMPONENT DESC: Operating Controls
Condition: Unknown
Due 15 January 2002
Resolved 10 January 2002
Lifesaving › Inflatable Liferafts
Issued 7 December 2001 Resolved
provide proof of liferaft servicing completion and call for USCG inspection. LEGACY COMPONENT DESC: Inflation Characteristics
Condition: Unknown
Due 15 January 2002
Resolved 16 January 2002
Construction/Loadline
Issued 3 January 2001 Resolved
Install metal through hole fittings and valves on both sides of collision bulkhead. In way of (3) non metallic piping penetrations IAW 46 CFR 182.720
Condition: Unknown
Due 4 January 2001
Resolved 4 January 2001
Construction/Loadline
Issued 3 January 2001 Resolved
Tighten hose clamp on grey water hose in way of aft berthing bilge through hull connection.
Condition: Unknown
Due 4 January 2001
Resolved 4 January 2001
Construction/Loadline
Issued 3 January 2001 Resolved
Properly repair cracked weld between hull and keel on port side.
Condition: Unknown
Due 4 January 2001
Resolved 4 January 2001
Construction/Loadline
Issued 3 January 2001 Resolved
Make forward engine room bulkhead watertight in way of (4) through bulkheadpenetrations in front of main engine.
Condition: Unknown
Due 4 January 2001
Resolved 4 January 2001
Construction/Loadline
Issued 3 January 2001 Resolved
Repair sewage through hole flange in forward peak space.
Condition: Unknown
Due 4 January 2001
Resolved 4 January 2001
Documentation
Issued 14 January 2000 Resolved
Provide current stability letter when issued._x001C_
Condition: Unknown
Due 14 January 2000
Resolved 14 January 2000
Engineering
Issued 26 November 1999 Resolved
STARBOARD FUEL SHUTOFF INOPERABLE - FULE LINE INTEFERES WITH OPERATIONS - MODIFY SYSTEM.
Condition: Unknown
Due 26 November 1999
Resolved 26 November 1999
Lifesaving
Issued 26 November 1999 Resolved
INSTALL QUICK RELEASE CLIP ON LIFERING W/LIGHT
Condition: Unknown
Due 26 November 1999
Resolved 26 November 1999
Navigation
Issued 26 November 1999 Resolved
INSTALL LOCK PIN FOR HYDRAULIC RAM END STARBOARD SIDE. REVERSE PIN AND DOUBLE NUT ON STARBOARD SIDE TILLER.
Condition: Unknown
Due 26 November 1999
Resolved 26 November 1999
Lifesaving
Issued 26 November 1999 Resolved
REPLACE SART BATTERIES
Condition: Unknown
Due 26 November 1999
Resolved 26 November 1999
Electrical
Issued 26 November 1999 Resolved
INSTALL OUTLET BOX COVER IN STATEROOM C.
Condition: Unknown
Due 26 November 1999
Resolved 26 November 1999
Fire Fighting
Issued 26 November 1999 Resolved
DEMONSTRATE FIXED FIRE FIGHTING SYSTEM OPERATION AFTER ENGINE INSTALLATION.
Condition: Unknown
Due 26 November 1999
Resolved 26 November 1999
Lifesaving
Issued 26 November 1999 Resolved
REPLACE/SERVICE HYDROSTATIC RELEASE FOR EPIRBS INCLUDE CHECK IN ISM INSPECTION PROCEDURES.
Condition: Unknown
Due 26 November 1999
Resolved 26 November 1999
Navigation
Issued 25 August 1997 Resolved
missing emergency radio placard
Condition: Unknown
Due 25 August 1997
Resolved 25 August 1997
Navigation
Issued 13 January 1997 Resolved
repair as new steering arm hydraulic ram bracket
Condition: Unknown
Due 15 January 1997
Resolved 27 January 1997
Construction/Loadline
Issued 13 January 1997 Resolved
shaft log in way of center shaft wasted and leaking renew as original
Condition: Unknown
Due 15 January 1997
Resolved 27 January 1997
Engineering
Issued 13 January 1997 Resolved
repair stbd mde oil pressure alarm
Condition: Unknown
Due 16 January 1997
Resolved 27 January 1997
Electrical
Issued 13 January 1997 Resolved
electrical power panel on bridge missing breakers/blanks. install blanks accordingly
Condition: Unknown
Due 16 January 1997
Resolved 27 January 1997
Lifesaving
Issued 13 January 1997 Resolved
renew 12 parachute (SOLAS) distress signals and 6 red hand held distress signals
Condition: Unknown
Due 15 January 1997
Resolved 27 January 1997
Lifesaving
Issued 13 January 1997 Resolved
Install lifejacket placard andd inflatable survival craft placard
Condition: Unknown
Due 15 January 1997
Resolved 27 January 1997
Construction/Loadline
Issued 13 January 1997 Resolved
repair leak in bilge manifold port side E/R and R/W strainer on PME
Condition: Unknown
Due 27 January 1997
Resolved 27 January 1997
Construction/Loadline
Issued 13 January 1997 Resolved
repair as new fasteners in thru hull slammer tank half valve
Condition: Unknown
Due 15 January 1997
Resolved 27 January 1997
Navigation
Issued 13 January 1997 Resolved
repair as new rudders where they struck propellors.
Condition: Unknown
Due 27 January 1997
Resolved 27 January 1997
Construction/Loadline
Issued 13 January 1997 Resolved
Plug holes with suitable type watertight fixture in way of aft blkd port side. 4 hole engineroom.
Condition: Unknown
Due 15 January 1997
Resolved 27 January 1997
Construction/Loadline
Issued 13 January 1997 Resolved
install plug in drain line at centerline of hull in E/R
Condition: Unknown
Due 15 January 1997
Resolved 27 January 1997
Construction/Loadline
Issued 13 January 1997 Resolved
Repair as new enginebed frame for port engine
Condition: Unknown
Due 15 January 1997
Resolved 27 January 1997
Construction/Loadline
Issued 13 January 1997 Resolved
submit plans to repair crack in hull on stbd bow adjacent to F/W tank
Condition: Unknown
Due 15 January 1997
Resolved 27 January 1997
Accommodation/Occupational Safety
Issued 13 January 1997 Resolved
Install valve and inport securing device on MSD holding tank.
Condition: Unknown
Due 27 January 1997
Resolved 27 January 1997
Electrical
Issued 13 January 1997 Resolved
Electrical outlet in fwd peak in way of ovhd is shorted renew with watertight enclosure
Condition: Unknown
Due 27 January 1997
Resolved 27 January 1997
Lifesaving
Issued 13 January 1997 Resolved
Stoe child PFD's seperate from adults and label
Condition: Unknown
Due 27 January 1997
Resolved 27 January 1997
Navigation
Issued 2 January 1996 Resolved
Provide current editions of light list, tide tables, tidal current tables and nav rules.
Condition: Unknown
Due 10 January 1996
Resolved 10 January 1996
Engineering
Issued 2 January 1996 Resolved
Provide 30x30 flame screens for fuel tank vents._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 10 January 1996
Resolved 10 January 1996
Unknown
Issued 2 January 1996 Resolved
perform underway test of MDE's,comms,and conduct drills.
Condition: Unknown
Due 10 January 1996
Resolved 10 January 1996
Navigation
Issued 2 January 1996 Resolved
Provide .6 meter anchor dayshape.
Condition: Unknown
Due 9 January 1996
Resolved 10 January 1996
Engineering
Issued 2 January 1996 Resolved
Prove oil failure alarm for centerline engine.
Condition: Unknown
Due 10 January 1996
Resolved 10 January 1996
Lifesaving
Issued 2 January 1996 Resolved
Provide emergency check off list.
Condition: Unknown
Due 10 January 1996
Resolved 10 January 1996
Deck/Cargo
Issued 2 January 1996 Resolved
Demonstrate anchor windlass.
Condition: Unknown
Due 10 January 1996
Resolved 10 January 1996
Navigation
Issued 2 January 1996 Resolved
Provide 12inch bell.
Condition: Unknown
Due 10 January 1996
Resolved 10 January 1996
Fire Fighting
Issued 2 January 1996 Resolved
Provide pressure guage on discharge side of fire pump.
Condition: Unknown
Due 10 January 1996
Resolved 10 January 1996
Lifesaving
Issued 2 January 1996 Resolved
Label PFD lockers with numbers and types of jackets contained therein.
Condition: Unknown
Due 10 January 1996
Resolved 10 January 1996
Electrical
Issued 7 February 1994 Resolved
INSTALL A "LOCK-OUT" DEVICE TO PREVENT MAIN GENERATORS FROM BEING PUT ON THE LINE SIMULTANEOUSLY.
Condition: Unknown
Due 7 March 1995
Resolved 15 February 1994
Electrical
Issued 7 February 1994 Resolved
INSTALL AN AMMETER FOR NEWLY INSTALLED GENERATORS.
Condition: Unknown
Due 7 March 1994
Resolved 15 February 1994
Engineering
Issued 7 February 1994 Resolved
PROVIDE WRITTEN REPORT FROM NORTHSTAR PROPELLERS REGARDING CASTING FRACTURES IN PORT AND STBD PROPELLERS.
Condition: Unknown
Due 7 March 1994
Resolved 15 February 1994
Fire Fighting
Issued 14 January 1993 Resolved
INSTALL AN ENGINE SHUT DOWN INTERLOCK FOR THE FIXED HALON SYSTEM IN THE ENGINE ROOM.
Condition: Unknown
Due 14 January 1993
Resolved 14 January 1993
Unknown
Issued 14 January 1993 Resolved
Submit a proposed procedure for a deadweight survey to the USCG Marine Safety Center.
Condition: Unknown
Due 14 January 1993
Resolved 14 January 1993
Documentation
Issued 10 February 1992 Resolved
PROVIDE VESSEL'S STABILITY CALCULATIONS BY A NAVAL ARCHITECT FOR REVIEW ANDAPPROVAL BY CG MSC. VESSEL FOUND WITHOUT SOLID BALLAST REQUIRED BY VESSEL'S STABILITY LETTER ISSUED BY SDCMS ON 07JAN71. BALLAST TANK (FISH HOLD) WHICH REPLACED THE SOLID BALLAST MUST BE KEPT FULL AT ALL TIMES.
Condition: Unknown
Due 10 February 1992
Resolved 10 February 1992
Documentation
Issued 7 May 1990 Resolved
PROVIDE CURRENT LOADLINE CERTIFICATE. VESSEL MAY NOT OPERATE ON INTERNATIONAL VOYAGES UNTIL THIS ITEM IS COMPLETE
Condition: Unknown
Due 7 May 1990
Resolved 7 May 1990
Navigation
Issued 9 May 1989 Resolved
REPLACE TWO NON-METALLIC HYDRAULIC LINES TO THE STEERING SYSTEM THAT ARE DAMAGED. PROVIDE PROPER SUPPORT TO PREVENT REOCCURANCE TO SAME. TO BE CORRECTED PRIOR TO UNDERWAY WITH PASSENGERS.
Condition: Unknown
Due 9 May 1989
Resolved 9 May 1989
Electrical
Issued 5 May 1989 Resolved
PROVE THE PROPER OPERATION OF PORT AND STBD. SERVICE GENERATORS INCLUDING THE OPERATION OF THE STEERING SYSTEM.
Condition: Unknown
Due 5 May 1989
Resolved 5 May 1989
Documentation
Issued 5 May 1989 Resolved
PROVIDE OIL TRANSFER PROCEDURES ON BOARD.
Condition: Unknown
Due 5 May 1989
Resolved 5 May 1989
Lifesaving
Issued 5 May 1989 Resolved
SEPARATE THE STOWAGE OF CHILD LIFE PRESERVERS FROM THE ADULT LIFE PRESERVERS.
Condition: Unknown
Due 5 May 1989
Resolved 5 May 1989
Accommodation/Occupational Safety
Issued 5 May 1989 Resolved
PROVIDE METALLIC TRASH CANS WITH COVER TO REPLACE PLASTIC TRASH CANS IN THELOUNGE AREAS BELOW THE MAIN DECK.
Condition: Unknown
Due 5 May 1989
Resolved 5 May 1989
Electrical
Issued 10 May 1988 Resolved
INSTALL PROTECTIVE GUARD TO PORT AND STARBOARD SERVICE GENERATOR DRIVE PULLEY AND BELT FOR WATER PUMPS.
Condition: Unknown
Due 10 May 1988
Resolved 10 May 1988
Navigation
Issued 10 May 1988 Resolved
PROVIDE AN UPDATED MAGNETIC COMPASS DEVIATION CARD.
Condition: Unknown
Due 10 May 1988
Resolved 10 May 1988
Engineering
Issued 10 May 1988 Resolved
RERPAIR BILGE ALARM SYSTEM IN THE WHEELHOUSE.
Condition: Unknown
Due 10 May 1988
Resolved 10 May 1988
Unknown
Issued 10 May 1988 Resolved
LABEL EMERGENCY FUEL OIL SHUT-OFF.
Condition: Unknown
Due 10 May 1988
Resolved 10 May 1988
Unknown
Issued 10 May 1988 Resolved
STENCIL NAME AND HOMEPORT ON VESSEL'S STERN.
Condition: Unknown
Due 10 May 1988
Resolved 10 May 1988
Electrical
Issued 10 May 1988 Resolved
REPAIR INDICATOR LIGHT ON STARBOARD SERVICE GENERATOR.
Condition: Unknown
Due 10 May 1988
Resolved 10 May 1988
Engineering
Issued 12 May 1987 Resolved
REMOVE PETCOCKS FROM FUEL FILTERS,REPLACE FLAME BOWLS ON ALL FILTERS
Condition: Unknown
Due 12 May 1987
Resolved 12 May 1987
Engineering
Issued 12 May 1987 Resolved
RECONNECT EMERGENCY FUEL SHUTOFFS IN ENGINE ROOM
Condition: Unknown
Due 12 May 1987
Resolved 12 May 1987
Engineering
Issued 12 May 1987 Resolved
PROVE ALL 3 MAIN ENGINES,ALARMS AND GAUGES
Condition: Unknown
Due 12 May 1987
Resolved 12 May 1987
Navigation
Issued 12 May 1987 Resolved
PROVE ANCHOR LIGHT
Condition: Unknown
Due 12 May 1987
Resolved 12 May 1987
Navigation
Issued 12 May 1987 Resolved
PRESENT VESSEL FOR FCC SATISFACTORY INSPECTION
Condition: Unknown
Due 12 May 1987
Resolved 12 May 1987
Navigation
Issued 12 May 1987 Resolved
PRESENT COMPASS DEVIATION CARD
Condition: Unknown
Due 12 May 1987
Resolved 12 May 1987
Navigation
Issued 12 May 1987 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 12 May 1987
Resolved 12 May 1987
Engineering
Issued 29 April 1986 Resolved
INSTALL EXHUAST DUCTING FROM ENGINE ROOM BILGES.
Condition: Unknown
Due 29 April 1986
Resolved 29 April 1986
Engineering
Issued 29 April 1986 Resolved
INSTALL FIRE SHIELDS (APPROVED) ON FUEL FILTERS.(5 SETS)
Condition: Unknown
Due 29 April 1986
Resolved 29 April 1986
Construction/Loadline
Issued 29 January 1986 Resolved
MAKE SATISFACTORY REPAIRS TO CRACKS IN FASHION PLATE AFT CORNER, STARBOARD SIDE OF DECK HOUSE. PRESENT PROPOSAL TO [name withheld] PRIOR TO MAKING PERMANENT REPAIR. THIS REQUIREMENT TO BE COMPLETED PRIOR TO CARRYING PASSENGERS FOR HIRE.
Condition: Unknown
Due 29 January 1986
Resolved 29 January 1986

Casualty record · 3

3 September 2006Routine · role: Involved in a Marine Casualty · activity 2769572
30 July 2008Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 4811186
19 January 2023Major Marine Casualty · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 7624790
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record