Records from 1985 to 2025. Most recent: inspection, 22 September 2025.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 72
22 September 2025
Internal Structural Exam · Drydock Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 8240176
12 June 2025
COI Inspection
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 8158774
1 October 2024
Annual Inspection
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 8013117
20 May 2024
Drydock Exam · Internal Structural Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7915741
25 September 2023
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 7797709
22 September 2022
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 7558878
5 October 2021
Examination of Repairs · Internal Structural Exam · Drydock Exam · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 7327894
2 June 2021
Annual Inspection
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 7276282
12 May 2020
COI Inspection
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 6952197
21 November 2019
DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 6860148
24 September 2019
Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 6821859
17 September 2018
DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 6542552
16 October 2017
Deficiency Check · Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 6288358
6 September 2017
Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 6261084
10 February 2017
Examination of Repairs · Damage Survey
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 6085905
29 July 2016
Administrative Inspection
Administrative · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 5956551
4 February 2016
Deficiency Check · Internal Structural Exam · Drydock Exam · Annual Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 5809795
21 March 2014
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4821620
17 February 2010
Hull Examination · COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3681719
27 February 2009
Hull Examination · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3424928
9 April 2008
Re-Inspection · Administrative Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3180668
3 April 2007
Re-Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2900480
28 February 2007
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2879361
29 March 2006
Re-Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2611724
6 April 2005
COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2327838
22 February 2005
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2296643
29 July 2004
Administrative Inspection
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 2149641
1 April 2004
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 2035416
17 February 2004
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 2007604
3 April 2003
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1771348
15 April 2002
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1604867
13 February 2002
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1487690
2 April 2001
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1370075
27 March 2000
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1440297
15 March 2000
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1051807
15 February 2000
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1461241
31 March 1999
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 786778
17 March 1999
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 808771
19 February 1999
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1129639
30 March 1998
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 787299
30 March 1998
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1122292
12 February 1998
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1111925
30 April 1997
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 19238
7 April 1997
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1097900
20 February 1997
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1107069
18 June 1996
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 113427
22 April 1996
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1085938
1 April 1996
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1078798
12 February 1996
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 877474
20 April 1995
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 861454
30 March 1995
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 834134
14 February 1995
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 846519
7 April 1994
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 857858
7 March 1994
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 855380
6 April 1993
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1145413
9 February 1993
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 832718
27 March 1992
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 951371
24 February 1992
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 954994
26 March 1991
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 903822
8 February 1991
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1215902
28 March 1990
Deficiency Check · Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1242248
9 February 1990
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 907762
28 March 1989
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1041942
3 February 1989
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 887161
28 March 1988
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1299854
4 February 1988
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1329363
27 March 1987
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1327209
25 February 1987
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1308580
27 March 1986
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1305452
18 February 1986
Credit Drydock
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1295108
27 March 1985
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1287621
18 March 1985
Credit Drydock
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1287305
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 1 October 2024
Resolved
Rail courses or the equivalent must be installed so that no open space exists more than 4 inches high or alternatively, in diameter. Vessel rail courses have spaces of approximately 10 inches. Submit proposal to complete correction. Correction to be complete prior to 2025 passenger season.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 12 June 2025
Resolution: Rails have been closed in with wire rope and canvas dodger.
05 - Radio Communications › N/A - No Subsystem › Reserve source of energy
Issued 1 October 2024
Resolved
Any small passenger vessel the keel of which was laid after March 1, 1957, must have a reserve power supply located on the same deck as the main wheel house or at least one deck above the vessel's main deck, unless the main power supply is so situated, if—
(1) The vessel is of more than 100 gross tons; or
(2) Beginning March 25, 2009:
(i) The vessel carries more than 150 passengers or has overnight accommodations for more than 49 persons; or
(ii) The vessel operates on the high seas. vessel house batteries are located in engine room. Provide proposal to complete correction. Correction to be completed prior to 2025 passenger season.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 12 June 2025
Resolution: Battery added.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 1 October 2024
Resolved
EPIRB must be tested monthly and logged or otherwise documented. No documentation of EPIRB monthly test exists. Provide plan to document tests in the future.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 12 June 2025
Resolution: Operator performing tests and logging.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 1 October 2024
Resolved
The hailing port of the vessel must be marked on some clearly visible exterior part of the stern of the vessel. The markings required which may be made by the use of any means and materials which result in durable markings, must be made in clearly legible letters of the Latin alphabet or Arabic or Roman numerals not less than four inches in height. Hailing port is not marked. Complete prior to 2025 passenger season.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 12 June 2025
Resolution: Hailing port affixed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 1 October 2024
Resolved
Each portable fire extinguisher on a vessel must be of an approved type. Portable extinguishers not in brackets required by approval as indicated on extinguisher label. Provide approved brackets prior to 2025 season.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 12 June 2025
Resolution: Correct brackets now installed. Owner to set brackets to correct height per NFPA10.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 October 2024
Resolved
Where flexible nonmetallic hose is permitted for use in piping systems by this section, it must meet SAE J-1942. Flexible nonmetallic hose must be complete with factory-assembled end fittings requiring no further adjustment of the fittings on the hose, or field attachable type fittings may be used. Hose end fittings must comply with SAE J-1475. Steering gear hose is clear tubing. Provide proposal and complete replacement prior to 2025 season.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 12 June 2025
Resolution: Hose was for bleeder use only. Port was removed and plugged.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 26 September 2023
Resolved
On a vessel of at least 26 feet a visual and audible alarm must be provided at the operating station to indicate a high water level. Fuel space and wheelhouse bilge alarms are not functional.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 September 2023
Resolution: Float switches were replaced and observed functional.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 22 September 2022
Resolved
Vessels constructed of wood must provide bilge level alarms in all watertight compartments. Vessel forepeak does not have bilge alarm.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 October 2022
Resolved 18 October 2022
Resolution: Bilge alarm installed and tested in presence of inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 22 September 2022
Resolved
Each battery used in an item of lifesaving equipment must be replaced if the expiration date of the battery has passed. Life buoy water light and 03 buoyant apparatus/life float water light batteries were found expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 October 2022
Resolved 18 October 2022
Resolution: Batteries replaced in kind.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 22 September 2022
Resolved
A hatch cover must be attached to the frame or coaming by hinges, captive chains or other devices of substantial strength to prevent its loss. Laz and tank space hatch cover are disconnected.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 October 2022
Resolved 18 October 2022
Resolution: Hatch retainers installed.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 5 October 2021
Resolved
When required by the marine inspector, a portion of the inspection must be conducted while the vessel is underway so that the hull and internal structure can be observed. At completion of drydock, conduct underway sea-trial in presence of MI to receive credit for exam.
46 CFR 176.802 (c)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 May 2022
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 May 2020
Resolved
Vessel needs to complete all tests and inspections required annually
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 June 2021
Resolution: Completed tests/inspections w/ MI.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 November 2019
Resolved
Vessel unable to complete tests and inspections due to lay up for winter.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 May 2020
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 17 September 2018
Resolved
Remote fuel shut off on aft port fuel tank.
Due 19 October 2018
Resolved 17 October 2018
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 6 September 2017
Resolved
Provide ammonia inhalants and iodone
Due 29 September 2017
Resolved 29 September 2017
Lifesaving › Hand Flares › Expired
Issued 6 September 2017
Resolved
Provide new flares, restricted to daylight ops only
Due 29 September 2017
Resolved 29 September 2017
Lifesaving › Lifefloat › Paddle
Issued 6 September 2017
Resolved
Provide new paddles
Due 29 September 2017
Resolved 29 September 2017
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 6 September 2017
Resolved
Label
Due 29 September 2017
Resolved 29 September 2017
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 6 September 2017
Resolved
Label 10 additional
Due 29 September 2017
Resolved 29 September 2017
Lifesaving › Lifebuoys › Serviceable
Issued 7 June 2016
Resolved
Repalce wasted life ring
Due 7 June 2016
Resolved 10 June 2016
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 7 June 2016
Resolved
Provide new /proper batteries for all floating water lights.
Due 24 June 2016
Resolved 10 June 2016
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 7 June 2016
Resolved
Properly mark stern with correct home port
Due 24 June 2016
Resolved 14 June 2016
Resolution: Stern properly mark with correct home port.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 7 June 2016
Resolved
Provide aspirin for first aid kit
Due 24 June 2016
Resolved 10 June 2016
Communications › Radio Communications › VHF Radiotelephone
Issued 7 June 2016
Resolved
Provide VHF radio with DCS+GPS capability.
Due 24 June 2016
Resolved 10 June 2016
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 29 March 2006
Resolved
Provide current tide/current tables.
Action required: 705 - Other - as specified
Due 14 April 2006
Resolved 10 April 2006
Construction/Loadline › Structures › Machinery Space Opening
Issued 29 March 2006
Resolved
Mark engine room escape hatch.
Action required: 705 - Other - as specified
Due 14 April 2006
Resolved 10 April 2006
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 29 March 2006
Resolved
Prior to operating more than 20 miles from a harbor of safe refuge, replace expired batteries in PFD lights.
Action required: 705 - Other - as specified
Due 10 April 2006
Resolved 10 April 2006
Lifesaving
Issued 15 February 2000
Resolved
PROPERLY REPLACE THE REFLECTIVE TAPE ON ALL CHILDRENS LIFEJACKETS PRIOR TO APRIL 1, 2000 TO THE SATISFACTION OF THE ARTTENDING MARINE INSPECTOR.
Condition: Unknown
Due 15 February 2000
Resolved 15 February 2000
Construction/Loadline
Issued 12 February 1998
Resolved
REPLACE WEDGES UNDER FRAME #1, PORT SIDE IN FOREPEAK.
Condition: Unknown
Due 12 February 1998
Resolved 12 February 1998
Construction/Loadline
Issued 12 February 1998
Resolved
REPAIR ROTTED AREA OF FRAME, 3RD FROM FORWARD BULKHEAD IN FUEL TANK SPACE, STBD SIDE.
Condition: Unknown
Due 12 February 1998
Resolved 12 February 1998
Construction/Loadline
Issued 12 February 1998
Resolved
MAKE VESSEL AVAILABLE FOR UNDERWAY INTERNAL STRUCTURAL EXAMINATION PRIOR TOCARRYING PASSENGERS FOR HIRE, AND NLT 01 APR 98.
Condition: Unknown
Due 12 February 1998
Resolved 12 February 1998
Construction/Loadline
Issued 12 February 1996
Resolved
REEF-OUT ROTTED AREAS AND TREAT WITH WOOD TREATMENT (CUPRINOL) BOTH SHAFT LOGS.
Condition: Unknown
Due 12 February 1996
Resolved 12 February 1996
Construction/Loadline
Issued 12 February 1996
Resolved
REEF-OUT ROTTED AREA AND TREAT WOOD IN WAY OF DECK BEAM AFT OF THE ENGINE ROOM HATCH.
Condition: Unknown
Due 12 February 1996
Resolved 12 February 1996
Construction/Loadline
Issued 12 February 1996
Resolved
REEF-OUT ROTTED AREAS AND TREAT WOOD IN WAY OF THE TRANSVERSE FRAME, KEELSON, AND FLOOR TIMBER UNDERNEATH THE LAZARETTE HATCH.
Condition: Unknown
Due 12 February 1996
Resolved 12 February 1996
Construction/Loadline
Issued 12 February 1996
Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE, MAKE VESSEL AVAILABLE FOR UNDERWAY SEA TRIALS AND HULL EXAMINATION.
Condition: Unknown
Due 12 February 1996
Resolved 12 February 1996
Electrical
Issued 30 March 1995
Resolved
PROPERLY CAP WIRING IN ENGINE ROOM IN WAY OF FORWARD BULKHEAD NO LATER THAN08 APRIL, 1995.
Condition: Unknown
Due 8 April 1995
Resolved 31 March 1995
Lifesaving
Issued 30 March 1995
Resolved
REPLACE IN KIND ROTTED LINE ON LIFE FLOATS AND BUOYANT APPARATUS PRIOR TO OPERATION AND NO LATER THAN 01 APRIL 1995.
Condition: Unknown
Due 1 April 1995
Resolved 31 March 1995
Engineering
Issued 30 March 1995
Resolved
PLACE PROTECTIVE GUARD ON STARBOARD MAIN ENGINE ALTERNATOR BELTS NO LATER THAN 30 APRIL, 1995.
Condition: Unknown
Due 30 March 1995
Resolved 30 March 1995
Construction/Loadline
Issued 30 March 1995
Resolved
REPLACE FLEXIBLE HOSE ON BILGE OVERBOARD LINE NO LATER THAN 08 APRIL, 1995.
Condition: Unknown
Due 8 April 1995
Resolved 31 March 1995
Deck/Cargo
Issued 7 April 1994
Resolved
REPLACE FLAME SCREENS ON STARBOARD SIDE FUEL TANK VENT.
Condition: Unknown
Due 14 April 1994
Resolved 26 April 1994
Lifesaving
Issued 7 April 1994
Resolved
LABEL CORRECT CAPACITY ON 15 MAN LIFE FLOAT.
Condition: Unknown
Due 14 April 1994
Resolved 26 April 1994
Navigation
Issued 7 April 1994
Resolved
PROVE PROPER OPERATION OF DECA RADAR OR REMOVE FROM VESSEL.
Condition: Unknown
Due 7 May 1994
Resolved 26 April 1994
Lifesaving
Issued 28 March 1990
Resolved
INSTALLED FLOAT FREE LINKS IAW 46 CFR 180.20
Condition: Unknown
Due 28 March 1990
Resolved 28 March 1990