Records from 1981 to 2008. Most recent: inspection, 10 June 2008.
Everything above is free. The detail below — the inspection history, the deficiency record, the tow units and the documentation record — is Professional, $39 a month. Sign in.
Inspection history · 96
10 June 2008
Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 3232824
9 June 2008
Type not recorded
No type recorded · Commandant (CG-CVC) · Activity 3231913
26 July 2006
Annual Inspection · Internal Structural Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2723662
6 March 2006
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2597255
27 February 2006
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2592613
15 February 2006
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2588909
15 February 2006
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2591351
26 July 2005
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2440629
7 July 2005
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2418078
25 May 2005
MTSA Verification · COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2368203
9 July 2004
Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2127280
8 July 2003
Periodic Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1839670
8 July 2003
Deficiency Check · In-Service Inspection · Administrative Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1874276
10 September 2002
Administrative Inspection
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1673534
22 August 2002
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1665125
23 July 2002
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1650572
19 June 2002
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1712983
15 April 2002
Administrative Inspection
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1605038
7 December 2001
In-Service Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1410712
29 October 2001
In-Service Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1076798
29 October 2001
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1076800
27 August 2001
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1072749
30 July 2001
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 524795
27 July 2001
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1069817
29 June 2001
Deficiency Check · Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1450650
8 June 2001
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1471767
4 August 2000
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1058269
10 July 2000
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1413779
9 July 1999
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1424780
22 June 1999
Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1192110
10 May 1999
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 466322
20 April 1999
Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 790220
4 August 1998
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 459641
10 July 1998
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1392952
4 November 1997
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 511251
2 October 1997
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1111124
30 September 1997
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 782249
11 July 1997
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1451247
6 June 1997
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 699823
7 April 1997
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 447569
12 July 1996
Hull Examination · COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1083157
23 February 1996
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1402200
26 October 1995
Type not recorded
No type recorded · MSD ST. PAUL · USCG Heartland District (CGD-H) · Activity 8822
26 October 1995
Damage Survey
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1186344
27 January 1995
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1444937
13 January 1995
Damage Survey
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1142125
12 January 1995
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 38563
30 November 1994
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1367228
18 April 1994
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 645162
18 March 1994
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 471260
1 March 1994
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 853757
16 February 1994
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1163712
15 February 1994
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 853484
1 February 1994
Damage Survey
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 852845
31 January 1994
Type not recorded
No type recorded · MSD PEORIA · USCG Heartland District (CGD-H) · Activity 72507
31 January 1994
Type not recorded
No type recorded · MSD PEORIA · USCG Heartland District (CGD-H) · Activity 148119
17 May 1993
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 528126
16 March 1993
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 472214
30 December 1992
COI Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 832774
12 October 1992
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 128657
21 May 1992
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 465592
11 March 1992
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 830325
11 March 1992
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 953976
23 December 1991
Administrative
Administrative · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 946907
27 August 1991
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 467980
17 July 1991
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 450123
15 July 1991
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 538622
14 February 1991
Examination of Repairs
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1219202
9 January 1991
COI Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 930025
7 January 1991
Administrative
Administrative · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1242465
28 December 1990
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 922447
6 December 1990
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 455288
21 December 1989
Examination of Repairs · Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 904402
9 November 1989
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 903648
22 October 1989
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 472429
22 October 1989
Damage Survey
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1341134
31 July 1989
Damage Survey
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 893970
28 April 1989
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 517701
1 March 1989
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 892218
8 February 1989
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1340300
3 February 1989
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 899286
13 January 1989
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 887868
29 August 1988
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 446547
6 August 1988
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 502057
2 August 1988
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 437660
25 March 1988
MARPOL Annex II Examination · Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 990546
10 March 1988
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 532640
20 January 1987
COI Inspection · Damage Survey · Hull Examination · Examination of Repairs
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1009655
29 April 1986
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1299232
16 April 1986
COI Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 986060
1 April 1986
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 465306
14 June 1985
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 473219
21 April 1985
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 448094
23 December 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 968142
8 April 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1276314
13 February 1981
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 970098
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 10 June 2008
Resolved
33 CFR 155.1070(e) - The CG may require a vessel owner or operator to revise a Response Plan at any time if the response plan does not meet the requirements of this subpart. The CG will notify the vessel owner or operator in writing of any deficiencies or operating restrictions. This VRP lacked QI services and OSRO coverage.
Due 10 June 2008
Resolved 11 June 2008
Resolution: VRP Control #02568 was formally inactivated by USCG VRP Program.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 22 June 2005
Resolved
Repair or renew guard to prime mover exhaust piping in accordance with 46 CFR 58.10-5.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 July 2005
Resolved 7 July 2005
Resolution: exhaust insulation/guard on prime mover was properly repaired.
Deck/Cargo › Cargo Heating
Issued 23 July 2002
Resolved
Prior to placing Thermal Fluid Heater in operation, conduct required operational test IAW 46CFR63.05 in presence of CG Marine Inspector, on or before 23 Aug 02. LEGACY COMPONENT DESC: Thermal Fluid Heater
Condition: Unknown
Action required: 705 - Other - as specified
Due 23 October 2002
Resolved 12 August 2003
Engineering
Issued 29 June 2001
Resolved
MAKE THERMAL FLUID HEATER READY FOR INSPECTION & TESTING OF REPAIRS.
Condition: Unknown
Due 29 June 2001
Resolved 29 June 2001
Deck/Cargo
Issued 29 June 2001
Resolved
MAKE PERMANENT REPAIRS TO PV PIPING ON #4 STBD CARGO TANK.
Condition: Unknown
Due 29 June 2001
Resolved 29 June 2001
Construction/Loadline
Issued 8 June 2001
Resolved
Replace 2 gussets in bow rake. 1 port, 1 stbd at corner wrapper.
Condition: Unknown
Due 29 June 2001
Resolved 2 July 2001
Construction/Loadline
Issued 8 June 2001
Resolved
Replace stiffener in bow rake (headlog) stbd outboard most.
Condition: Unknown
Due 29 June 2001
Resolved 2 July 2001
Deck/Cargo
Issued 10 July 2000
Resolved
Test alarms and shutdowns on thermal fluid heater; conduct internal inspection of thermal fluid heater; conduct tests in presence and to the satisfaction of cognizant [name withheld] 10 Aug 00.
Condition: Unknown
Due 10 July 2000
Resolved 10 July 2000
Deck/Cargo
Issued 10 July 1998
Resolved
DISMANTLE & PREPARE P/V VALVES FOR INSPECTION BY USCG MARINE INSPECTOR IN ACCORDANCE WITH 46 CFR 32.20-5.
Condition: Unknown
Due 10 July 1998
Resolved 10 July 1998
Construction/Loadline
Issued 10 July 1998
Resolved
RESTENCIL VESSEL'S NAME ON BOW PORT AND STARBOARD SIDES IN ACCORDANCE WITH 46 CFR 32.05-15.
Condition: Unknown
Due 10 July 1998
Resolved 10 July 1998
Electrical
Issued 10 July 1998
Resolved
CONDUCT OPERATIONAL TEST OF GENERATOR & THERMAL FLUID HEATER IN THE PRESENCE OF A USCG MARINE INSPECTOR IN ACCORDANCE WITH 46 CFR 52.01-35.
Condition: Unknown
Due 10 July 1998
Resolved 10 July 1998
Electrical
Issued 11 July 1997
Resolved
PROVE PROPER OPERATION OF THE GENERATOR OVERSPEED DEVICE IN ACCORDANCE WITH46 CFR 111.12-1
Condition: Unknown
Due 11 August 1997
Resolved 5 September 1997
Construction/Loadline
Issued 11 July 1997
Resolved
#1 S WING VOID, ADD VERTICLE STIFFENERS AT FRAMES 31, 32, & 33 FROM CARGO TANK BOTTOM LONGS TO BOTTOM SHELL LONGS #s 3, 4, 5, & 6 AND AT FRAME #34 ATBOTTOM LONGS #1,2,&3, IAW 46CFR32.60-1.
Condition: Unknown
Due 2 December 1997
Resolved 2 December 1997
Construction/Loadline
Issued 11 July 1997
Resolved
#1 S WING VOID, RENEW FLANGES ON BOTTOM LONG #12 AT FRAMES 32 & 33, IAW 46CFR32.60-1.
Condition: Unknown
Due 2 December 1997
Resolved 2 December 1997
Construction/Loadline
Issued 11 July 1997
Resolved
#1 S WING VOID, CROP & RENEW FRAME 34 FROM 2' INBOARD OF SIDESHELL TO 5' INBOARD & 1' ABOVE BOTTOM SHELL TO CARGO TANK BOTTOM, IAW 46CFR32.60-1.
Condition: Unknown
Due 2 December 1997
Resolved 2 December 1997
Deck/Cargo
Issued 11 July 1997
Resolved
PERFORM AIR TEST ON ALL CARGO TANKS AND PROVE TIGHT IN PRESENCE OF A MARINEINSPECTOR, IAW 46CFR32.60-1.
Condition: Unknown
Due 11 July 1997
Resolved 11 July 1997
Construction/Loadline
Issued 11 July 1997
Resolved
GOUGE AND WELD FRACTURE ON PORT AFT BUTTON CLEAT.
Condition: Unknown
Due 2 December 1997
Resolved 2 December 1997
Deck/Cargo
Issued 11 July 1997
Resolved
#4 P WING VOID, REPAIR FRACTURE IN CARGO TANK AT FRAME 8 AT 6TH SIDE LONG, IAW 46CFR32.60-1.
Condition: Unknown
Due 11 July 1997
Resolved 11 July 1997
Construction/Loadline
Issued 11 July 1997
Resolved
#4 WING VOID, CROP AND RENEW FRAME 5 FROM DECK DOWN 6' AND SIDESHELL TO CARGO TANK, IAW 46CFR32.60-1.
Condition: Unknown
Due 11 July 1997
Resolved 11 July 1997
Deck/Cargo
Issued 11 July 1997
Resolved
#4 P WING VOID, CLEAN CARGO TANK SIDE AT FRAME 5 FROM DECK TO LOWER CONNECTION AND CHECK FOR FRACTURES, IAW 46CFR32.60-1.
Condition: Unknown
Due 11 July 1997
Resolved 11 July 1997
Deck/Cargo
Issued 11 July 1997
Resolved
#4 P WING VOID, REPAIR FRACTURE AT FRAME 4 TO CARGO TANK AT LOWER OUTBOARD CORNER, IAW 46CFR32.60-1.
Condition: Unknown
Due 11 July 1997
Resolved 11 July 1997
Construction/Loadline
Issued 11 July 1997
Resolved
#2 P WING VOID, CROP AND RENEW FRAME 25 FROM #5 SIDELONG TO DECK AND SIDESHELL TO CARGO TANK, IAW 46 CFR 32.60-1.
Condition: Unknown
Due 11 July 1997
Resolved 11 July 1997
Deck/Cargo
Issued 11 July 1997
Resolved
#3 P WING VOID, REPAIR CARGO TANK FRACTURE AT FRAME #14, TANK SIDE TO TANK BOTTOM, IAW 46CFR32.60-1.
Condition: Unknown
Due 11 July 1997
Resolved 11 July 1997
Construction/Loadline
Issued 11 July 1997
Resolved
#3 P WING VOID, GOUGE AND WELD FRACTURED RELEASE IN FRAME 11 AT #1 SIDELONG, IAW 46CFR32.60-1.
Condition: Unknown
Due 11 July 1997
Resolved 11 July 1997
Construction/Loadline
Issued 11 July 1997
Resolved
PROVIDE TO [name withheld], AL, THE DETAILED INTERNAL SURVEY AND COMPLETED REPAIRS LIST AS ACCOMPLISHED IN HOUSTON, TX 07/96.
Condition: Unknown
Due 29 July 1997
Resolved 5 September 1997
Construction/Loadline
Issued 11 July 1997
Resolved
#1 S WING VOID; GOUGE & WELD FRACTURED WELDS ON FRAMES 27, 28, 29, & 30 AT BOTTOM LONG #13 CONNECTIONS, IAW 46CFR32.60-1.
Condition: Unknown
Due 2 December 1997
Resolved 2 December 1997
Deck/Cargo
Issued 11 July 1997
Resolved
PROVE PROPER OPERATION OF THE FIRED THERMAL FLUID HEATER IN ACCORDANCE WITH46 CFR 61.30-15 & 61.30-20
Condition: Unknown
Due 11 August 1997
Resolved 5 September 1997
Deck/Cargo
Issued 11 July 1997
Resolved
#3 P WING VOID, REPAIR FRACTURE IN CARGO TANK AT FRAME 11 AT TANK SIDE TO TANK BOTTOM, IAW 46CFR32.60-1.
Condition: Unknown
Due 11 July 1997
Resolved 11 July 1997
Construction/Loadline
Issued 11 July 1997
Resolved
#4 P WING VOID, CROP AND RENEW LOWER 3' OF FRAMES 9 & 6 FROM SIDESHELL TO CARGO TANK, IAW 46CFR32.60-1.
Condition: Unknown
Due 11 July 1997
Resolved 11 July 1997
Construction/Loadline
Issued 11 July 1997
Resolved
#2 S WING VOID, CROP AND RENEW FLANGE ON BOTTOM LONG #13 AT FRAMES 22&24, IAW 46 CFR 32.60-1.
Condition: Unknown
Due 2 December 1997
Resolved 2 December 1997
Deck/Cargo
Issued 11 July 1997
Resolved
#2 S WING VOID, REPAIR FRACTURE AT SIDE LONG #6 ON CARGO TANK AT FRAME #22,IAW 46CFR32.60-1.
Condition: Unknown
Due 2 December 1997
Resolved 2 December 1997
Construction/Loadline
Issued 11 July 1997
Resolved
#2 S WING VOID, GOUGE & WELD FRACTURED WELDS AT BOTTOM LONG #13 AT FRAME #19, IAW 46CFR32.360-1.
Condition: Unknown
Due 2 December 1997
Resolved 2 December 1997
Construction/Loadline
Issued 11 July 1997
Resolved
#2 S WING VOID, ATTACH SOUNDING TUBE TO DECK CONNECTION, IAW 46CFR32.60-1.
Condition: Unknown
Due 2 December 1997
Resolved 2 December 1997
Construction/Loadline
Issued 11 July 1997
Resolved
#3 S WING VOID, CROP AND RENEW FRAME #14 FROM SIDE SHELL TO CENTER OF FRAMEFROM CENTER OF LIGHTING HOLE TO DECK, IAW 46CFR32.60-1.
Condition: Unknown
Due 2 December 1997
Resolved 2 December 1997
Construction/Loadline
Issued 11 July 1997
Resolved
#3 WING VOID, CROP AND RENEW FRAME #17 FROM CENTER OF LIGHTING HOLES TO SIDESHELL, FROM BOTTOM SHELL TO DECK, IAW 46CDR32.60-1.
Condition: Unknown
Due 2 December 1997
Resolved 2 December 1997
Construction/Loadline
Issued 11 July 1997
Resolved
#4 S WING VOID, RENEW TRIPPED #6 STRINGER AT BHD #2, IAW 46CFR32.60-1.
Condition: Unknown
Due 2 December 1997
Resolved 2 December 1997
Construction/Loadline
Issued 11 July 1997
Resolved
#4 S WING VOID, CROP & RENEW FRAMES 3 & 4 FROM SIDESHELL TO CARGO TANK & DECK DOWN 5', IAW 46CFR32.60-1.
Condition: Unknown
Due 2 December 1997
Resolved 2 December 1997
Construction/Loadline
Issued 11 July 1997
Resolved
#4 S WING VOID, CROP AND RENEW FRAMES 5, 6, 7, & 8 FROM CENTER OF LIGHTING HOLES TO SIDESHELL & BOTTOM SHELL TO DECK, IAW 46CFR32.60-1.
Condition: Unknown
Due 2 December 1997
Resolved 2 December 1997
Construction/Loadline
Issued 11 July 1997
Resolved
#4 S WING VOID, CROP AND RENEW FRAME #9 FROM SIDESHELL TO CARGO TANK AT SIDELONG #3 & UNDER CARGO TANK TO BOTTOM LONG #9 & FROM CENTER OF LIGHTING HOLES TO SIDESHELL AT SIDELONG # 5 TO DECK, IAW 46CFR32.60-1.
Condition: Unknown
Due 2 December 1997
Resolved 2 December 1997
Construction/Loadline
Issued 11 July 1997
Resolved
STERN VOID, GOUGE & WELD FRACTURE AT UNDERDECK LONG PORT QUARTER OVERHEAD, & RENEW 2ND STRINGER TO SIDELONG BRACKET FROM DECK, IAW 416CFR32.60-1
Condition: Unknown
Due 2 December 1997
Resolved 2 December 1997
Deck/Cargo
Issued 11 July 1997
Resolved
#1P WING VOID, GOUGE & WELD FRACTURES IN CARGO TANK TO FRAME BOTTOM OUTBOARD CONNECTION ON FRAMES 26, 27, 29, 30 & 33, IAW 46CFR32.60-1.
Condition: Unknown
Due 2 December 1997
Resolved 2 December 1997
Construction/Loadline
Issued 11 July 1997
Resolved
#1P WING VOID, CROP AND RENEW FRAME 28 FROM BOTTOM LONG #9 TO 12 & BOTTOM SHELL TO CARGO TANK BOTTOM, IAW 46CFR32.60-1.
Condition: Unknown
Due 2 December 1997
Resolved 2 December 1997
Deck/Cargo
Issued 11 July 1997
Resolved
#1 P WING VOID, REPAIR FRACTURES IN CARGO TANK BETWEEN FRAMES 27 & 28 AT 6TH SIDELONG, IAW 46CFR32.60-1.
Condition: Unknown
Due 2 December 1997
Resolved 2 December 1997
Construction/Loadline
Issued 11 July 1997
Resolved
#2 P WING VOID, GOUGE AND WELD FRACTURED WELD AT FRAMES 20 & 22 TO BOTTOM LONG #15 CONNECTIONS, IAW 46CFR32.60-1.
Condition: Unknown
Due 2 December 1997
Resolved 2 December 1997
Construction/Loadline
Issued 11 July 1997
Resolved
#2 P WING VOID, GOUGE AND WELD FRACTURED WELD AT FRAMES 20 & 22 TO BOTTOM LONG #13 CONNECTIONS, IAW 46CFR32.60-1.
Condition: Unknown
Due 2 December 1997
Resolved 2 December 1997
Construction/Loadline
Issued 27 January 1995
Resolved
CLEAN, GAS FREE AND MAKE AVAILABLE FOR INTERNAL EXAMINATION BY A USCG INSPECTOR: BOW VOID, NOS. 1 & 2 P&S WING TANK/DOUBLE BOTTOMS. EFFECT PERMANENT REPAIRS TO CARGO LEAK IN NO. 2 WING VOID, POSSIBLE LEAK IN NO. 1 WING VOIDS.
Condition: Unknown
Due 27 January 1995
Resolved 1 February 1995
Construction/Loadline
Issued 13 January 1995
Resolved
PROCEED TO FINAL DESTINATION (NOLA). VSL IS NOT TO ON/OFF LOAD PRODUCT UPONOR PRIOR TO ARRIVAL WITHOUT PERMISSION FROM COGNIZANT OCMI/COTP. ALL VOIDS ARE TO BE VISUALLY INSPECTED TWICE PER WATCH DUE TO ACCUMULATION OF PRODUCTIN #1 PORT & #2 STBD VOIDS.
Condition: Unknown
Due 13 January 1995
Resolved 13 January 1995
Electrical
Issued 16 February 1994
Resolved
INSTALL COVER ON CABLE JUNCTION BOX LOCATED SIDE OF GENERATOR UNIT.
Condition: Unknown
Due 16 February 1994
Resolved 16 February 1994
Electrical
Issued 16 February 1994
Resolved
INSTALL BLANK PLATE OR CIRCUIT BREAKER IN OPENING OF SHORE POWER CIRCUIT BREAKER PANEL.
Condition: Unknown
Due 16 February 1994
Resolved 16 February 1994
Construction/Loadline
Issued 1 February 1994
Resolved
PRIOR TO LOADING VESSEL AND NO LATER THAN 20FEB94, GAS FREE THE #1 STARBOARD WING VOID AND MAKE NECESSARY REPAIRS TO THE SIDE PLATING.
Condition: Unknown
Due 1 February 1994
Resolved 1 February 1994
Deck/Cargo
Issued 9 January 1991
Resolved
PROPERLY MARK THE VESSEL'S CARGO HOSES IAW 33 CFR 154.500._x001C_
Condition: Unknown
Due 9 January 1991
Resolved 9 January 1991
Deck/Cargo
Issued 9 January 1991
Resolved
UPON OFFLOADING AND PRIOR TO RELOADING CARGO, MAKE PERMANENT REPAIRS TO THETHERMAL FLUID HEATER PARTLOW TEMPERATURE SYSTEM AND TEST IAW THE CG APPROVED TEST PROCEDURES. TESTING IS TO BE WITNESSED BY A CG MARINE INSPECTOR.
Condition: Unknown
Due 9 January 1991
Resolved 9 January 1991
Deck/Cargo
Issued 9 January 1991
Resolved
UPON OFFLOADING AND PRIOR TO RELOADING CARGO, MAKE PERMANENT REPAIRS TO THEFUEL OIL/AIR MODULATOR MOTOR AND TEST IAW THE CG APPROVED TEST PROCEDURES. TESTING IS TO BE WITNESSED BY A CG MARINE INSPECTOR.
Condition: Unknown
Due 9 January 1991
Resolved 9 January 1991
Deck/Cargo
Issued 9 January 1991
Resolved
UPON OFFLOADING AND PRIOR TO RELOADING CARGO, DEMONSTRATE PROPER OPERATION OF THE THERMAL FLUID HEATER COIL TEMPERATURE SWITCHES. TEST IS TO BE CONDUCTED IAW THE CG APPROVED TEST PROCEDURES AND WITNESSED BY A CG MARINE INSPECTOR.
Condition: Unknown
Due 9 January 1991
Resolved 9 January 1991
Deck/Cargo
Issued 9 January 1991
Resolved
UPON OFFLOADING AND PRIOR TO RELOADING CARGO, RENEW THE LEAKING AIR RECEIVER RELIEF VALVE._x001C_
Condition: Unknown
Due 9 January 1991
Resolved 9 January 1991
Deck/Cargo
Issued 9 January 1991
Resolved
INSTALL MISSING SAFETY GUARD ON THE THERMAL FLUID HEATER IN WAY OF THE DRIVE BELTS FOR THE UNIT BLOWER AND THE CIRCULATING PUMP.
Condition: Unknown
Due 9 January 1991
Resolved 9 January 1991
Deck/Cargo
Issued 9 January 1991
Resolved
IN ACCORDANCE WITH THE APPROVED THERMAL FLUID HEATER TEST PROCEDURES MAKE PERMANENT REPAIRS TO THE EXCESS TEMP. SWITCH WHICH WILL PREVENT THE OPERATING TEMPERATURE OF THE FLUID MEDIUM FROM EXCEEDING 400 DEGREES F. _x001C_(AT PRESENT TIME THE PHYSICAL STOP IS MISSING).
Condition: Unknown
Due 9 January 1991
Resolved 9 January 1991
Construction/Loadline
Issued 9 January 1991
Resolved
MAKE PERMANENT REPAIRS TO THE 1/2" HOLE IN WAY OF THE #3 PORT WING VOID DECK PLATE. MAINTAIN TEMPORARY REPAIRS UNTIL PERMANENT REPAIRS CAN BE EFFECTED.
Condition: Unknown
Due 9 January 1991
Resolved 9 January 1991
Construction/Loadline
Issued 9 January 1991
Resolved
MAKE PERMANENT REPAIRS TO THE 6" HOLE IN WAY OF THE #1 PORT WING VOID DECK PLATE. MAINTAIN TEMPORARY REPAIRS UNTIL PERMANENT REPAIRS CAN BE EFFECTED._x001C_
Condition: Unknown
Due 9 January 1991
Resolved 9 January 1991
Construction/Loadline
Issued 9 January 1991
Resolved
MAKE PERMANENT REPAIRS TO THE 10" FRACTURE LOCATED BETWEEN THE PORT STERN CORNER MOORING BUTTONS._x001C_
Condition: Unknown
Due 9 January 1991
Resolved 9 January 1991
Construction/Loadline
Issued 9 January 1991
Resolved
MAKE PERMANENT REPAIRS TO THE 10" DECK KNUCKLE FRACTURE AND THE TWO 3" DECKPLATE FRACTURES LOCATED IN WAY OF THE #1 STARBOARD WING VOID.
Condition: Unknown
Due 9 January 1991
Resolved 9 January 1991
Deck/Cargo
Issued 9 January 1991
Resolved
PRIOR TO LOADING CARGO, MAKE PERMANENT REPAIRS TO THE #1 CARGO TANK PV VALVE IN WAY OF THE WASTED THREADS AND BENT STAND PIPE.
Condition: Unknown
Due 9 January 1991
Resolved 9 January 1991
Deck/Cargo
Issued 28 December 1990
Resolved
PRIOR TO LOADING CARGO, MAKE PERMANENT REPAIRS TO THE INOPERATIVE CARGO _x001C_PIPING VALVE IN WAY OF THE #4 CARGO TANK.
Condition: Unknown
Due 28 December 1990
Resolved 28 December 1990
Construction/Loadline
Issued 22 October 1989
Resolved
MAKE PERMANENT REPAIRS TO NUMBER 2 PORT WING TANK BELOW THE WATERLINE, TO PREVENT LEAKAGE OF WATER AND CARGO INTO THE WING TANK.
Condition: Unknown
Due 22 October 1989
Resolved 22 October 1989
Construction/Loadline
Issued 1 March 1989
Resolved
COMPLETE RENEWAL OF LOADLINE MARKING AND DRAFT MARKS ON VESSEL.
Condition: Unknown
Due 1 March 1989
Resolved 1 March 1989
Deck/Cargo
Issued 13 January 1989
Resolved
MAKE REPAIRS TO MISSING/LOOSE REFACTORY MATERIAL IN THERMAL FLUID HEATER. PRIOR TO 28 FEB 89.
Condition: Unknown
Due 13 January 1989
Resolved 13 January 1989
Construction/Loadline
Issued 20 January 1987
Resolved
RENEWED PLATE IN #2P WING VOID AS FOLLOWS: ONE 6'2"X3/8X21" PORT SIDE GUNNEL PLATE; ONE 6'2"X3/8X33" PORT SIDE PLATE.
Condition: Unknown
Due 20 January 1987
Resolved 20 January 1987
Construction/Loadline
Issued 20 January 1987
Resolved
ONE 32"X5/8X4'0" PORT STERN CORNER KNUCKLE RENEWED; ONE 50"X3/4X4'0" PORT STERN CORNER RENEWED.
Condition: Unknown
Due 20 January 1987
Resolved 20 January 1987
Construction/Loadline
Issued 20 January 1987
Resolved
RENEWED PLATE IN #1P WING VOID AS FOLLOWS: ONE 4'6"X5/8X46" OF PORT TRANSITION KNUCKLE; ONE 12'2"X5/8X5'8" OF STARBOARD TRANSITION KNUCKLE.
Condition: Unknown
Due 20 January 1987
Resolved 20 January 1987
Construction/Loadline
Issued 20 January 1987
Resolved
RENEWED PLATE IN #1S WING VOID AS FOLLOWS: ONE 20"X3/8X20" STBD BOW SIDE PLATE; ONE 18'3"X3/8X30" PORT BOW DECK PLATE.
Condition: Unknown
Due 20 January 1987
Resolved 20 January 1987