Inspection history · 64
8 September 2014
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4977695
24 June 2013
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4630030
15 June 2013
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4622706
26 March 2004
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2031803
2 May 2002
Permit to Proceed · Damage Survey
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1611664
18 April 2002
Permit to Proceed
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1606410
23 June 2001
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1065425
18 May 2001
Hull Examination · Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1387036
12 March 2001
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1061201
28 February 2001
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 141229
15 February 2001
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 127092
6 April 2000
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1048321
3 April 2000
Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1047571
22 March 2000
COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1463568
31 March 1999
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1426191
12 February 1999
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1470968
15 November 1998
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 185318
21 August 1998
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 62604
27 June 1998
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1127093
26 June 1998
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 106219
26 March 1998
COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1418316
22 July 1997
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1116070
25 June 1997
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1411496
13 February 1997
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1430345
22 April 1996
Administrative
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1080785
27 March 1996
COI Inspection · Hull Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 885231
18 January 1996
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1396429
30 November 1994
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1367229
18 April 1994
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 645163
18 March 1994
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 469456
16 February 1994
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 853960
1 February 1994
Damage Survey
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 852723
17 May 1993
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 447824
12 January 1993
Deficiency Check
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 826920
30 December 1992
COI Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1140369
25 March 1992
Re-Inspection · Examination of Repairs
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 947851
23 December 1991
Administrative
Administrative · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 946604
27 August 1991
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 444750
17 July 1991
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 474415
15 July 1991
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 500286
30 April 1991
Examination of Repairs · Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1215577
26 April 1991
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 467959
13 April 1991
Damage Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1218010
22 February 1991
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 927946
9 January 1991
COI Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1239241
27 December 1990
Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 483721
23 February 1990
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 475120
13 December 1989
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 930336
13 November 1989
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1212952
23 October 1989
Damage Survey
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1036703
31 July 1989
Damage Survey
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 897156
19 February 1989
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 475552
3 February 1989
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1213744
13 January 1989
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1201076
29 August 1988
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 482310
25 March 1988
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1297368
30 November 1987
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 469645
22 January 1987
Hull Examination · COI Inspection · Damage Survey
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1001003
23 June 1986
Type not recorded
No type recorded · MSO NASHVILLE · Activity 444159
29 April 1986
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1001057
25 April 1986
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1306490
1 April 1986
COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1305593
21 April 1985
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 527874
14 April 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1273931
Unknown
Issued 18 May 2001
Resolved
Provide initial 30 year midbody gauging report (IAW 46 CFR 31.10-21a) to [name withheld], Florida.
Condition: Unknown
Due 18 May 2001
Resolved 18 May 2001
Construction/Loadline
Issued 22 March 2000
Resolved
Replace all deteriorated gasket material for double bottom void hatches as necessary.
Condition: Unknown
Due 22 March 2000
Resolved 22 March 2000
Construction/Loadline
Issued 12 February 1999
Resolved
All crushed splash bulkheads in double bottom voids to be cropped and renewed to the satisfaction of the cognizant OCMI at the vessel's next drydocking (MAR01).
Condition: Unknown
Due 12 February 1999
Resolved 12 February 1999
Deck/Cargo
Issued 12 February 1999
Resolved
Suspected crack in cargo tank #2 starboard side, bottom forward corner of bay #3. Crack to be monitored by company reps and re-evaluated by USCG marine inspector within 30 days (10MAR99).
Condition: Unknown
Due 12 February 1999
Resolved 12 February 1999
Navigation
Issued 25 June 1997
Resolved
PROVIDE PROPER NAVIGATION LIGHTS (PORT/STBD/STERN) TO COMPLY WITH INLAND_x001C_ AND INT'L RULES.
Condition: Unknown
Due 25 June 1997
Resolved 25 June 1997
Deck/Cargo
Issued 30 December 1992
Resolved
THERMAL FLUID HEATER MODULATOR INOPERABLE. REPLACE OR REPAIR PRIOR TO COMPLIANCE DATE.
Condition: Unknown
Due 30 December 1992
Resolved 30 December 1992
Construction/Loadline
Issued 13 April 1991
Resolved
GAS-FREE MAKE AVAILABLE FOR INTERNAL INSPECTION #3 STBD WING VOID. MAKE PERMENENT REPAIRS TO FRACTURE LOCATED @ APPROX. 6'DRAFT SIDE SHELL TO THE SATISFACTION OF ATTENDING CG MARINE INSPECTOR.
Condition: Unknown
Due 13 April 1991
Resolved 13 April 1991
Deck/Cargo
Issued 9 January 1991
Resolved
IN ACCORDANCE WITH THE APPROVED THERMAL FLUID HEATER TEST PROCEDURES MAKE PERMANENT REPAIRS TO THE EXCESS TEMP. SWITCH WHICH WILL PREVENT THE OPERATING TEMPERATURE OF THE FLUID MEDIUM FROM EXCEEDING 400 DEGREES F. (ATPRESENT TIME THE PHYSICAL STOP IS MISSING).
Condition: Unknown
Due 9 January 1991
Resolved 9 January 1991
Deck/Cargo
Issued 9 January 1991
Resolved
UPON OFFLOADING AND PRIOR TO RELOADING CARGO, RENEW THE LEAKING AIR RECEIVER RELIEF VALVE.
Condition: Unknown
Due 9 January 1991
Resolved 9 January 1991
Electrical
Issued 9 January 1991
Resolved
INSTALL GUARDS AND GLOBES IN WAY OF THE MACHINERY SPACE ELECTRICAL LIGHTINGFIXTURES.
Condition: Unknown
Due 9 January 1991
Resolved 9 January 1991
Deck/Cargo
Issued 9 January 1991
Resolved
UPON OFFLOADING AND PRIOR TO RELOADING CARGO, MAKE PERMANENT REPAIRS TO THETHERMAL FLUID HEATER PARTLOW TEMPERATURE CONTROL SYSTEM AND TEST IAW THE _x001C_CG APPROVED TEST PROCEDURES. TESTING IS TO BE WITNESSED BY A CG MARINE INSPECTOR.
Condition: Unknown
Due 9 January 1991
Resolved 9 January 1991
Deck/Cargo
Issued 9 January 1991
Resolved
UPON OFFLOADING AND PRIOR TO RELOADING CARGO, MAKE PERMANENT REPAIRS TO THE#2 CARGO TANK PV VALVE STAND PIPE IN WAY OF THE DRESSER COUPLING TEMPORARY REPAIR.
Condition: Unknown
Due 9 January 1991
Resolved 9 January 1991
Deck/Cargo
Issued 9 January 1991
Resolved
MARK THE VESSEL'S CARGO HOSES IAW 33 CFR 154.500.
Condition: Unknown
Due 9 January 1991
Resolved 9 January 1991
Deck/Cargo
Issued 9 January 1991
Resolved
UPON OFFLOADING AND PRIOR TO RELOADING CARGO, MAKE PERMANENT REPAIRS TO THEFUEL OIL/AIR MODULATOR MOTOR AND TEST IAW THE CG APPROVED TEST PROCEDURES. TESTING IS TO BE WITNESSED BY A CG MARINE INSPECTOR.
Condition: Unknown
Due 9 January 1991
Resolved 9 January 1991
Deck/Cargo
Issued 9 January 1991
Resolved
UPON OFFLOADING AND PRIOR TO RELOADING CARGO, DEMONSTRATE PROPER OPERATION OF THE THERMAL FLUID HEATER COIL TEMPERATURE SWITCHES. TEST IS TO BE CONDUCTED IAW THE CG APPROVED PROCEDURES AND WITNESSED BY AN ATTENDING USCGMARINE INSPECTOR.
Condition: Unknown
Due 9 January 1991
Resolved 9 January 1991
Deck/Cargo
Issued 9 January 1991
Resolved
UPON OFFLOADING AND PRIOR TO RELOADING CARGO, MAKE PERMANENT REPAIRS TO THETHERMAL FLUID HEATER REFRACTORY.
Condition: Unknown
Due 9 January 1991
Resolved 9 January 1991
Deck/Cargo
Issued 9 January 1991
Resolved
INSTALL MISSING SAFETY GUARD ON THE THERMAL FLUID HEATER IN WAY OF THE DRIVE BELTS FOR THE UNIT BLOWER AND CIRCULATING PUMP.
Condition: Unknown
Due 9 January 1991
Resolved 9 January 1991
Construction/Loadline
Issued 23 October 1989
Resolved
MAKE PERMANENT REPAIRS TO SHELL PLATING AND FRAMEWORK IN STARBOARD CORNER OF BOW BOX. NO CARGO IS TO BE LOADED IN #1 CARGO TANK, & IS AUTHORIZED TO HAVE WATER-FILLED #1 PORT STRBD WING TANKS FOR BALLAST PURPOSES. DRAFT NOT TO EXCEED 8'9". (RESTRICTIONS IN PLACE UNTIL REPAIRS COMPLEATED).
Condition: Unknown
Due 23 October 1989
Resolved 23 October 1989
Deck/Cargo
Issued 13 January 1989
Resolved
MAKE PERMANENT REPAIRS TO THE MISSING/LOOSE REFRACTORY MATERIAL IN THE THERMAL FLUID HEATER PRIOR TO 28FEB89
Condition: Unknown
Due 13 January 1989
Resolved 13 January 1989
Construction/Loadline
Issued 22 January 1987
Resolved
ONE 7'1"X3/4X8'2" PORT BOW VERTICLE CORNER RENEWED. ONE 7'4"X3/8X6'0" VERTICLE KNUCKLE RENEWED.
Condition: Unknown
Due 22 January 1987
Resolved 22 January 1987
Construction/Loadline
Issued 22 January 1987
Resolved
ONE 6'3"X3/8X5'0" PORT STERN PLATE RENEWED. ONE 20"X3/8X20" PORT STERN PLATE RENEWED. ONE 7"X4"X3/8X7'6" VERTICLE KNUCKLE RENEWED.
Condition: Unknown
Due 22 January 1987
Resolved 22 January 1987
Construction/Loadline
Issued 22 January 1987
Resolved
ONE 19"X3/8X19" PORT #3 WING VOID DECK PLATE RENEWED.
Condition: Unknown
Due 22 January 1987
Resolved 22 January 1987
Construction/Loadline
Issued 22 January 1987
Resolved
ONE 20"X3/8X20" STBD #3 WING VOID SIDE SHELL PLATE RENEWED.
Condition: Unknown
Due 22 January 1987
Resolved 22 January 1987
Deck/Cargo
Issued 1 April 1986
Resolved
MAKE PERMANENT REPAIRS TO THE THERMAL FLUID HEATER COMBUSTION CONTROL FOR PROPER FUEL AND AIR MIXTURE.
Condition: Unknown
Due 1 April 1986
Resolved 1 April 1986
Documentation
Issued 1 April 1986
Resolved
HAVE VESSEL'S LOAD LINE CERTIFICATE ENDORSED BY ABS OR PAINT OVER LOAD LINEMARKS. VESSEL MAY NOT TRANSIT ON THE LIMITED GREAT LAKES ROUTE UNLESS THE CERTIFICATE IS ENDORSED.
Condition: Unknown
Due 1 April 1986
Resolved 1 April 1986
Deck/Cargo
Issued 1 April 1986
Resolved
MAKE PERMANENT REPAIRS TO THE DAMAGED CARGO TANK HATCH COVER GASKETS ON ALLCARGO TANKS.
Condition: Unknown
Due 1 April 1986
Resolved 1 April 1986
Engineering
Issued 1 April 1986
Resolved
MAKE PERMANENT REPAIRS OR REPLACE THE AIR RECEIVER RELIEF VALVE AND PROVE SATISFACTORY OPERATION.
Condition: Unknown
Due 1 April 1986
Resolved 1 April 1986
Deck/Cargo
Issued 1 April 1986
Resolved
MAKE PERMANENT REPAIRS ON THE P/V VALVES FOR CARGO TANKS ONE THRU THREE.
Condition: Unknown
Due 1 April 1986
Resolved 1 April 1986
Deck/Cargo
Issued 1 April 1986
Resolved
REPLACE EXISTING FLEXIBLE FUEL HOSES WITH COAST GUARD APPROVED TYPE ON THE DIESEL ENGINES.
Condition: Unknown
Due 1 April 1986
Resolved 1 April 1986