MAURY USCG vessel records
← All vessels

MISS BEA

MISS BEA is a 1970 passenger vessel (inspected). The Coast Guard has recorded 13 inspections since 2016, most recently in February 2026, along with 22 deficiencies.

Records from 2016 to 2026. Most recent: inspection, 10 February 2026.

Built
1970
Last inspected
10 February 2026
Documentation
Expired · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 10 February 2026
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WYZ2603
Flag
UNITED STATES
Maury page id
psix-46716

Documentation record

Registered dimensions (L × B × D)61.4 ft × 16.1 ft × 7.8 ft
Registered tonnagegross 58 / net 39
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBREAUX'S BAY-CRAFT INC · LOREAUVILLE, LA, UNITED STATES · built 1970
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it58 - Regulatory (Subpart C or D), Gross Ton
39 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 13

10 February 2026 Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8308919
14 October 2025 Internal Structural Exam · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8243881
31 March 2025 Internal Structural Exam · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8098821
7 May 2024 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7908282
27 April 2023 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7671722
28 April 2022 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7429796
19 February 2021 COI Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7136313
30 April 2020 Annual Inspection · Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6938920
25 April 2019 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6670157
26 April 2018 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6393198
22 March 2017 Type not recorded
No type recorded · Station Venice · USCG Heartland District (CGD-H) · Activity 6109990
27 February 2017 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6092868
16 February 2016 Internal Structural Exam · Deficiency Check · COI Inspection · Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5812639

Deficiency record · 22

03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 14 October 2025 Resolved
Hatch covers must be attached to the hatch frame or coaming by hinges, captive chains, or other devices of substantial strength to prevent its loss. Wire connecting hatch cover on aft deck frayed/worn. 46 CFR 179.360(b)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 October 2025
Resolved 27 October 2025
Resolution: Rcvd objective evidence of newly installed captive chains properly attached.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 October 2025 Resolved
Each waterlight must be of an approved type constructed in accordance with 160.012. Batteries in water lights were missing the required nuts on top mount connections. 46 CFR 180.30-1(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 October 2025
Resolution: Rcvd objective evidence of the new installed wing nuts on the batteries.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 14 October 2025 Resolved
All ducts shall be of rigid permanent construction of fireproof material and reasonably gastight from end to end. Ventilation ducts from engine space were missing covers. 46 CFR 182.20-45(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 October 2025
Resolution: Rcvd objective evidence of fabricatted and fitted ventilation covers.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 14 October 2025 Resolved
All piping, valves, and fittings of the fire main system shall be in accordance with good marine practice and suitable for the service intended. The hose connection on the fire pump deck valve was observed leaking. 46 CFR 182.15-5(c)
Action required: 10 - Deficiency Rectified
Resolved 14 October 2025
Resolution: New Connection was procured and installed.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - cracking
Issued 14 October 2025 Resolved
Where exhaust piping passes through watertight bulkheads the watertight integrity of the bulkheads shall be maintained. Cracked noted on the generator exhaust weld connection at the forward bulkhead of the aft steering space. 46 CFR 182.15-20(d)
Action required: 10 - Deficiency Rectified
Resolved 14 October 2025
Resolution: Owner completed welding repair to the satisfaction of the attending marine inspector.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 14 October 2025 Resolved
Remote fuel shutoff stations must be marked in clearly legible letters. Remove fuel shut off valve on deck was missing label. 46 CFR 185.608
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 October 2025
Resolution: Rcvd objective evidence of the labeling being marked.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 October 2025 Resolved
Each life ring on a vessel must be approved in accordance with 160.050. the life ring was found damaged and the plug missing. 46 CFR 180.70(b)(1)
Action required: 10 - Deficiency Rectified
Resolved 14 October 2025
Resolution: New procured life ring was installed.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 14 October 2025 Resolved
A vessel must carry a first aid kit that meets the requiremenets in 46 CFR 199.175(b)(10). Expired Medicine were found in the kit.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 October 2025
Resolution: Expired medicine were removed and new medicine was placed in the vessel.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 7 May 2024 Resolved
Each vessel that operates on the high seas, or that operates beyond three nautical miles from the coastline of the Great Lakes, must have on board a FCC Type Accepted Category 1, 406 MHz EPIRB. The Marine Inspector found the EPRIB batteries were expired. 46 CFR 180.64
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 May 2024
Resolution: Pictures of brand new EPIRB received. All sat.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 7 May 2024 Resolved
All escape hatches and other emergency exits used as means of escape must be marked on both sides in clearly legible letters at least 50 millimeters (2 inches) high: “EMERGENCY EXIT, KEEP CLEAR”, unless such markings are deemed unnecessary by the cognizant OCMI. Marine Inspector observed the emergency escape from the crew accommodation space is missing the required markings. 46 CFR 185.606
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 June 2024
Resolved 5 June 2024
Resolution: Received pictures of signage installed. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 7 May 2024 Resolved
At each initial and subsequent inspection for certification, reinspection, and at every other vessel inspection the marine inspector shall require that all observed unsafe practices and hazardous situations be corrected. Generator exhaust through the lazarette was observed to be uninsulated. 46 CFR 176.25-50(Old T)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 30 May 2024
Resolution: Received Pictures of wrapped exhaust. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 7 May 2024 Resolved
All vessels shall be provided with a satisfactory arrangement for draining any watertight compartment other than small buoyancy compartments, under all practical conditions. Bilge piping in the lazarette was observed to be deteriorated. 46 CFR 182.25-1(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 June 2024
Resolved 5 June 2024
Resolution: Received pictures of new piping installation in kind. All sat.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 27 April 2023 Resolved
Ships must be provided with a VHF radio installation capable of transmitting and receiving Digital Selective Calling (DSC) on the frequency 156.525 MHz (channel 70), and it must be able to initiate the transmission of distress alerts on channel 70 from the position from which the ship is normally navigated. A new VHF radio was installed on board with incorrect MMSI number and no connection to GPS for proper use of DSC distress call. Input correct MMSI number and GPS connection for proper function of DSC distress call. 47 CFR 80.1085(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 May 2023
Resolution: Received photograph of VHF radio with GPS inputs
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 28 April 2022 Resolved
Each ring life buoy must be of an approved type, constructed in accordance with Subpart (Q) 160.050 of this chapter. The grab line and the 60' cast line were severely deteriorated and un-serviceable. 46 CFR 180.30-1 46 CFR 160.050
Action required: 60 - Rectify deficiencies prior to movement
Resolved 31 May 2022
Resolution: The grab line and 60' life line were replaced.
Construction/Loadline › Hull › Weld
Issued 27 February 2017 Resolved
Starboard side engine exhaust piping has cracks where the piping penetrates the bulkhead on the lazarette side.
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Due 27 February 2017
Resolved 27 February 2017
Resolution: Vessel rep welded cracked weld seam on the lazarette side. There were no visible cracks on the engine room side of the bulkhead.
Electrical › Electric Generation Source (service) › Conductor
Issued 27 February 2017 Resolved
Portside engine starter wires have exposed copper. The sheathing is worn through to the wire.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 February 2017
Resolved 27 February 2017
Resolution: Vessel rep placed some electrical tape on the wiring to prevent a connection of the exposed sections.
Navigation › Piloting/Steering › Marine Charts
Issued 27 February 2017 Resolved
Vessel had outdated charts. The charts were outdated by 13 years.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 March 2017
Resolved 3 March 2017
Resolution: Vessel provided a reciept of newly purchased charts for the area of operation.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 27 February 2017 Resolved
Install a proper sized strainer on the bilge suction in the foward peak compartment bilge suction line. Line has no strainer.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 March 2017
Resolved 3 March 2017
Resolution: Vessel provided evidence of a properly installed strainer on the forward peak compartment.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 16 February 2016 Resolved
Crack identified in aft machinery bulkhead where Generator exhaust meets penetration in bulkhead. Crop & properly fit.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 1 March 2016
Resolved 23 February 2016
Resolution: Proper repair made to original as per attending USCG Marine Inspector.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 16 February 2016 Resolved
Fuel fill hose into fuel tank is cracked. Replace fuel line with proper.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 March 2016
Resolved 23 February 2016
Resolution: Fuel fill hose was replaced with proper to attending Marine Inspector.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 16 February 2016 Resolved
Fwd and aft fuel tanks are missing grounding bondage. Fit both with proper grounding.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 March 2016
Resolved 23 February 2016
Resolution: Fuel tanks were properly grounded to satisfaction of attending Marine Inspector.
Engineering › Diesel Engine (propulsion-direct drive) › Exhaust Manifold
Issued 16 February 2016 Resolved
Port & stbd engine exhaust dry pipes shall be protected with lagging. Both pipes were missing lagging.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 March 2016
Resolved 23 February 2016
Resolution: Port and stbd engine exhaust dry pipes were properly lagged satisfactory to attending marine inspector.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.