Records from 1984 to 2008. Most recent: inspection, 12 November 2008.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 50
12 November 2008
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3362011
25 October 2006
Deficiency Check · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2808007
6 March 2006
COI Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2597392
8 June 2005
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2383791
3 August 2004
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2154810
21 July 2004
Annual Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2134709
8 July 2004
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2153941
10 May 2004
Type not recorded
No type recorded · USCGC ASSATEAGUE (WPB 1337) · USCG Oceania District (CGD-O) · Activity 2071814
24 March 2004
Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2030636
14 August 2003
Deficiency Check · Annual Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1875292
26 April 2002
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1598533
19 March 2002
Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1494158
7 March 2002
Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1491891
4 April 2001
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1061879
10 March 2001
Type not recorded
No type recorded · USCGC WASHINGTON (WPB 1331) · USCG Oceania District (CGD-O) · Activity 1523456
9 March 2001
COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1397594
31 March 2000
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 818262
31 March 2000
Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1361371
23 March 2000
Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1369585
9 April 1999
Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1388780
20 March 1998
MARPOL Annex V Examination · Hull Examination · COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1437364
22 May 1995
Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1357199
24 April 1995
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1172882
2 March 1995
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1164597
1 July 1994
Deficiency Check · MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1463846
13 October 1993
Re-Inspection · MARPOL Annex V Examination · Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1362863
9 August 1993
Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1152972
1 July 1992
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 950274
4 May 1992
COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1263136
26 November 1991
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1420633
13 November 1991
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1353342
7 August 1991
Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1249342
15 March 1991
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 915323
6 December 1990
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1227472
28 November 1990
Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 922986
5 March 1990
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 921679
24 October 1989
Hull Examination · Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1214657
24 January 1989
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 894216
5 December 1988
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1341492
2 December 1988
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1034050
29 November 1988
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1207393
17 November 1988
COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1205574
18 May 1988
Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1341720
30 November 1987
Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1027493
11 May 1987
Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1028239
3 December 1986
Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1329744
12 May 1986
Credit Drydock
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 994333
6 December 1985
COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1302852
17 June 1985
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 983956
7 December 1984
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1284365
Personnel › Manning/Qualifications › CPR Certified Personnel
Issued 6 March 2006
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 April 2006
Resolved 20 June 2006
Resolution: VSL provided record of CPR training and FCC License
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 6 March 2006
Resolved
VESSEL HAD NO HISTORY OF DRUG TESTING AND HAD NO RECORD OF POSITIVE AND NEGATIVE TEST RESULTS ONBOARD
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 July 2006
Resolved 27 July 2006
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 6 March 2006
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 June 2006
Resolution: Master presented license
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 6 March 2006
Resolved
VESSEL HAS EXPIRED CERTIFICATE OF DOCUMENTATION, MUST GET CERTIFICATE PRIOR TO CARRYING PASSENGERS
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 June 2006
Resolution: VSL PRESENTED VALID COD
Lifesaving › Lifefloat › Lifeline
Issued 6 March 2006
Resolved
LIFELINE ON LIFEFLOAT IS EXTREMELY WARN AND DOES NOT PROVIDE ADEQUATE STRENGTH, MAKING THE LIFEFLOAT NOT FULLY OPERATIONAL. IN ADDITION, LIFEFLOATS ARE NOT PROPERLY STOWED
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 July 2006
Resolved 27 July 2006
Documentation › Logs/Records › Logbook (official)
Issued 6 March 2006
Resolved
VESSEL SHOWED NO RECORD OF PASSENGER COUNT ON BOARD VESSEL
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 June 2006
Resolution: VSL Presented log book with PAX count in it
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 6 March 2006
Resolved
LADDER AT UPPER DECK NEEDS TO REWELDED ENSURE THAT CRACKS ARE REMOVED IN ORDER TO PROVIDE ADEQUATE OCCUPATIONAL SAFETY TO PASSENGER AND CREW
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 June 2006
Resolution: Ladder found welded and stable
Fire Fighting › Fire Bucket › Stenciling
Issued 6 March 2006
Resolved
VESSEL DID NOT HAVE FIRE BUCKETS PROPERLY LABELED
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 July 2006
Resolved 27 July 2006
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 6 March 2006
Resolved
VESSEL MUST PROVIDE RECORD OF FIXED FIREFIGHTING SERVICING PRIOR TO CARRYING PASSENGERS
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 June 2006
Resolution: SERVICING REPORT PROVIDED TO USCG
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 6 March 2006
Resolved
LIFERING LIFE LINE MUST HAVE BUOYANT LINE ATTACHED TO WATER ACTIVATED LIGHT. LIFERING MUST BE OF THE FLOAT FREE VARIETY
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 July 2006
Resolved 27 July 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 6 March 2006
Resolved
ALL DEAD END WIRING MUST BE REMOVED FROM THE ENGINE ROOM
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 June 2006
Resolution: Dead end wiring was removed from VSL
Engineering › Fuel Oil Service System › Filter
Issued 6 March 2006
Resolved
PROVIDE VALVES AT THE BOTTOM OF FUEL FILTERS
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 June 2006
Resolution: VALVES AT THE BOTTOM OF FUEL FILTERS PRESENT
Engineering › Sea-water System (primary cooling) › Piping
Issued 6 March 2006
Resolved
REPLACE ALL DETERIORATED SALT WATER COOLING LINES TO THE MAIN ENGINE. ENSURE THAT COOLING LINES ARE NOT CRACKED AND LINES ARE USED PROPERLY
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 June 2006
Resolution: COOLING LINES TO THE MAIN ENGINE IN SATISFACTORY CONDITION
Electrical › Electrical Distribution System (service) › Wiring
Issued 6 March 2006
Resolved
SECURE ALL WIRING UNDER THE CONTROL CONSOLE IN THE MAIN CABIN
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 June 2006
Resolution: Loose wiring throughout the vessel was secured
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 6 March 2006
Resolved
REMOVE ALL INSTALLED TOILETS OR PROVIDE MARINE SANITATION DEVICE
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 June 2006
Resolution: SEWAGE HOLDING TANK WAS INSTALLED ON VESSEL
Stability › Watertight Integrity › General
Issued 6 March 2006
Resolved
PLUG OR CONNECT THROUGHHULL FITTING IN FORWARD COMPARTMENT
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 June 2006
Resolution: Witnessed plugging of through hull fittings
Electrical › Electrical Distribution System (service) › Wiring
Issued 6 March 2006
Resolved
Secure loose electrical wires storage lockers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 August 2006
Resolved 5 December 2006
Accommodation/Occupational Safety › Ventilation › General
Issued 6 March 2006
Resolved
Route sewage tank vent line away from accomodation space.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 August 2006
Resolved 5 December 2006
Electrical › Electric Generation Source (service) › Conductor
Issued 6 March 2006
Resolved
Replace all melted electrical wire in engine room due to over heating.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 August 2006
Resolved 5 December 2006
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 6 March 2006
Resolved
Secure embarkation mount bracket
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 August 2006
Resolved 5 December 2006
Engineering › Generator (propulsion-electric) › Wiring
Issued 6 March 2006
Resolved
Conduct complete operational inspection of machinery and electrical systems throughout engineroom.
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 August 2006
Resolved 5 December 2006
Engineering › Bilge Water Management System › Interface Detector
Issued 6 March 2006
Resolved
Provide bilge alarm for fwd compartment.
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 August 2006
Resolved 5 December 2006
Accommodation/Occupational Safety › Occupational Safety › Smoking
Issued 6 March 2006
Resolved
Make smoke alarm in accomodation space operational
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 August 2006
Resolved 5 December 2006
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 6 March 2006
Resolved
Replace electrical box in galley near sink.
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 August 2006
Resolved 5 December 2006
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 8 June 2005
Resolved
Provide proof of enrollment in DAPI program IAW 46 CFR 16.
Due 22 June 2005
Resolved 5 December 2006
Navigation › Piloting/Steering › Magnetic Compass
Issued 8 June 2005
Resolved
Provide illuminated compass IAW 46 CFR 184.402. Vessel restricted to daylight operations only until corrected.
Due 22 June 2005
Resolved 5 December 2006
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 8 June 2005
Resolved
Provide current training logbook IAW 46 CFR 185.420.
Due 22 June 2005
Resolved 5 December 2006
Personnel › Training › First Aid/CPR
Issued 21 July 2004
Resolved
Provide Red Cross/First Aid cards for 50% of crew (NVIC 1-91).
Due 20 August 2004
Resolved 17 September 2004
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 21 July 2004
Resolved
Provide proof of EAP and appropriate training IAW 46 CFR 16.
Due 20 August 2004
Resolved 17 September 2004
Documentation › Certificates/Documents › FCC SSL
Issued 21 July 2004
Resolved
Provide valid FCC Safety Radio certificate.
Due 20 August 2004
Resolved 23 August 2004
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 21 July 2004
Resolved
Provide proof of crew training in fire and MOB IAW 46 CFR 185.420.
Due 20 August 2004
Resolved 23 August 2004
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 21 July 2004
Resolved
Provide maintenance records for lifesaving equipment to include lifefloats, ring buoy, EPIRB, and PFD's IAW 46 CFR 185.702.
Due 20 August 2004
Resolved 23 August 2004
Documentation › Manifests/Lists › Emergency Checkoff List
Issued 21 July 2004
Resolved
Post emergency instruction list IAW 46 CFR 185.510.
Due 20 August 2004
Resolved 22 July 2004
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 21 July 2004
Resolved
Provide current navigation pubs (US Coast Pilot and tidal currents) for operating area IAW 46 CFR 184.420.
Due 20 August 2004
Resolved 17 September 2004
Stability › Weathertight Integrity › General
Issued 21 July 2004
Resolved
Make forward emergency escape hatch weathertight IAW 46 CFR 179.360.
Due 20 August 2004
Resolved 23 August 2004
Fire Fighting › Means of Escape › Blocked
Issued 21 July 2004
Resolved
Make emergency escape hatch operable from both sides (currently secured from inside with line) IAW 46 CFR 177.500.
Due 20 August 2004
Resolved 23 August 2004
Operations/Management › Drills/Instruction › Safety Orientation
Issued 21 July 2004
Resolved
Provide copy of passenger safety orientation brief IAW 46 CFR 185.506.
Due 20 August 2004
Resolved 17 September 2004
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 21 July 2004
Resolved
Provide lifejacket donning placards for all types carried on board IAW 46 CFR 185.516.
Due 20 August 2004
Resolved 22 July 2004
Lifesaving › Lifebuoys › Immediately Available
Issued 21 July 2004
Resolved
Mount ring buoy so that it is readily accessible and can be rapidly cast loose IAW 46 CFR 180.70.
Due 20 August 2004
Resolved 17 September 2004
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 21 July 2004
Resolved
Provide operable floating waterlight for ring lifebuoy IAW 46 CFR 180.70(c)(6).
Action required: 705 - Other - as specified
Due 20 August 2004
Resolved 22 July 2004
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 21 July 2004
Resolved
Provide (1) child PFD IAW 46 CFR 180.71(b).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 July 2004
Fire Fighting › Remote Fuel Shutoff › General
Issued 21 July 2004
Resolved
Repair/prove proper operation of remote fuel shut off (port aft tank) IAW 46 CFR 182.455.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 July 2004
Stability › Watertight Integrity › General
Issued 21 July 2004
Resolved
Repair holes in port closet deck above E/R to maintain watertight integrity and allow for proper operation of fixed fire fighting system IAW 46 CFR 178.430.
Due 20 August 2004
Resolved 23 August 2004
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 21 July 2004
Resolved
Label and provide instructions for fixed firefighting system at pull handles and in protected space IAW 46 CFR 185.612.
Due 20 August 2004
Resolved 17 September 2004
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Location
Issued 21 July 2004
Resolved
Provide portable fire extinguisher in readily accessible location at operating station on upper deck IAW 46 CFR 181.520.
Due 20 August 2004
Resolved 17 September 2004
Engineering › Bilge Water Management System › Not Installed
Issued 21 July 2004
Resolved
Label bilge high level visual alarms at operating station IAW 46 CFR 182.530.
Due 20 August 2004
Resolved 17 September 2004
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 21 July 2004
Resolved
Prove proper operation of fixed fire fighting systems and associated shutdowns IAW 46 CFR 181.410.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 July 2004
Operations/Management › Drills/Instruction › Not Conducted
Issued 21 July 2004
Resolved
Conduct satisfactory MOB and fire drills in presence of USCG marine inspector IAW 46 CFR 185.520 and 185.524.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 July 2004
Engineering › Diesel Engine (propulsion-electric) › Block
Issued 21 July 2004
Resolved
Conduct tests of machinery and steering systems in presence of USCG marine inspector IAW 46 CFR 182.610 and 176.804.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 July 2004
Engineering › Bilge Water Management System › Not Operational
Issued 21 July 2004
Resolved
Prove proper operation of high-level bilge alarms IAW 46 CFR 182.530.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 July 2004
Electrical › Lighting (service)
Issued 14 August 2003
Resolved
Lighting fixture globe in the forward compartment was cracked. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Unknown
Due 1 September 2003
Resolved 31 March 2004
Fire Fighting › Ventilation Systems
Issued 14 August 2003
Resolved
The overhead in the engine room had several holes approx half inch in diameter. The space is protected with a fixed fire fighting system and there is no provisions to close the supply of air. LEGACY COMPONENT DESC: Ducts
Condition: Improper Installation
Due 1 September 2003
Resolved 22 September 2003
Documentation › Logs/Records
Issued 14 August 2003
Resolved
Company's EAP program was missing a hotline telephone number, drug information, and evidence of supervisory training. LEGACY COMPONENT DESC: Drug Test Records
Condition: Unknown
Due 14 September 2003
Resolved 22 September 2003
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 14 August 2003
Resolved
Vessel had only 4 serviceable child sized life jackets. Vsl required to have a quantity of 10 percent of total passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 August 2003
Resolved 15 August 2003
Resolution: Vessel procurred an additional child sized life jacket which brings their count to 10 percent of total passengers.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 14 August 2003
Resolved
Vessel had no evidence of logging or documentation indicating crew training.
Condition: Unknown
Due 1 September 2003
Resolved 15 August 2003
Resolution: Operator demonstrated the logging of drills and attested to the fact that future drills will be logged in the daily logbook.
Accommodation/Occupational Safety › Medical/First Aid
Issued 14 August 2003
Resolved
Vessels first aid kit contained some expired items. LEGACY COMPONENT DESC: Medicine Chest
Condition: Improper/Lack of Maintenance
Due 1 September 2003
Resolved 22 September 2003
Operations/Management › Drills/Instruction
Issued 14 August 2003
Resolved
Could not get u/w to perform drills due to lack of fuel. LEGACY COMPONENT DESC: Fire
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 September 2003
Resolved 15 August 2003
Resolution: MOB and fire drill were satisfactorily conducted.
Communications › Alarms/Indicators
Issued 14 August 2003
Resolved
Vessel did not have the visible bilge high level alarms labeled. LEGACY COMPONENT DESC: Bilge Alarm
Condition: Unknown
Due 1 September 2003
Resolved 22 September 2003
Engineering › Bilge Water Management System › Pump
Issued 14 August 2003
Resolved
Bilge pump unable to dewater forward compartment.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 September 2003
Resolved 15 August 2003
Resolution: Repairs made to check valve in bilge piping which allowed system to adequately dewater all water tight compartments.
Engineering › Bilge Water Management System › Pump
Issued 14 August 2003
Resolved
The portable hand pump had cracks in the discharge hose.
Condition: Improper/Lack of Maintenance
Due 1 September 2003
Resolved 15 August 2003
Resolution: Vessel procurred an adequated portable hand pump.
Accommodation/Occupational Safety › Occupational Safety
Issued 14 August 2003
Resolved
Machinery guard missing in the engine room on the stbd engine belt assembly. LEGACY COMPONENT DESC: Guards for Exposed Hazards
Condition: Placed in Improper Service
Due 1 September 2003
Resolved 15 August 2003
Resolution: Guard was replaced on the assembly.
Lifesaving › Embarkation Appliances/Stations
Issued 14 August 2003
Resolved
Forward space emergency means of escape hatch was sealed with caulking. The caulking was removed however the opening of the hatch remained stiff. LEGACY COMPONENT DESC: Accessability
Condition: Improper Installation
Due 1 September 2003
Resolved 22 September 2003
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 14 August 2003
Resolved
Vessel did not have a means to document the passenger count of each voyage.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 September 2003
Resolved 15 August 2003
Resolution: Vessel established a logbook to be kept in the dock office of the vessels slip indicating the number of passengers.
Documentation › Manuals/Policy Documentation
Issued 14 August 2003
Resolved
Vessel was missing placards of emergency instruction. LEGACY COMPONENT DESC: Emergency Instructions
Condition: Unknown
Due 1 September 2003
Resolved 22 September 2003
Engineering › Fuel Oil Storage/Transfer System
Issued 14 August 2003
Resolved
Flexible fuel hose not IAW SAE J-1942. LEGACY COMPONENT DESC: Hose
Condition: Improper Installation
Due 1 September 2003
Resolved 22 September 2003
Engineering › Sea-water System (primary cooling)
Issued 14 August 2003
Resolved
Starboard engine cooling overboard discharge assembly is not structurally supported which can cause the hose to kink. LEGACY COMPONENT DESC: Piping
Condition: Design Flaw
Due 1 September 2003
Resolved 31 March 2004
Stability › Watertight Integrity
Issued 14 August 2003
Resolved
Chain locker hatch missing securing device.
Due 1 September 2003
Resolved 31 March 2004
Lifesaving › Buoyant Apparatus
Issued 19 March 2002
Resolved
Replace lanyard and provide working waterlight for lifefloat in accordance with 46 CFR 180.175(d). LEGACY COMPONENT DESC: Lifefloat Waterlight
Due 27 March 2002
Resolved 27 March 2002
Resolution: Vessel operator provided new lanyard and working waterlight for lifefloat.
Lifesaving
Issued 19 March 2002
Resolved
Prove date of purchase or replace HRU for EPIRB in accordance with 46 CFR 185.740(b). LEGACY COMPONENT DESC: EPIRB HRU
Due 27 March 2002
Resolved 27 March 2002
Resolution: Vessel operator provided new HRU for EPIRB.
Documentation
Issued 19 March 2002
Resolved
Provide proof of adequate drug and alcohol program in accordance with 46 CFR Part 16. LEGACY COMPONENT DESC: Drug & Alcohol Program
Due 27 March 2002
Resolved 27 March 2002
Resolution: Vessel operator provided proof of adequate drug and alcohol program.
Documentation › Markings/Placards
Issued 19 March 2002
Resolved
Provide "Emergency Exit, Keep Clear" placard for hatch leading from berthing compartment on main deck in accordance with 46 CFR 185.606. LEGACY COMPONENT DESC: Emergency Exits
Due 27 March 2002
Resolved 27 March 2002
Resolution: Vessel operator provided placard for emergency exit.
Documentation › Markings/Placards
Issued 19 March 2002
Resolved
Provide maximum capacity placard for upper deck in accordance with 46 CFR 185.602(g). LEGACY COMPONENT DESC: Maximum Capacity Placard
Due 27 March 2002
Resolved 27 March 2002
Resolution: Vessel operator provided maximum capacity placard for upper deck.
Lifesaving › Lifejacket/PFD (Type III)
Issued 19 March 2002
Resolved
Replace (6) adult lifejackets in accordance with 46 CFR 180.71. Vessel passenger count is reduced by (6) adult until corrected. LEGACY COMPONENT DESC: Condition
Due 27 March 2002
Resolved 27 March 2002
Resolution: Vessel operator provided (6) new adult lifejackets.
Accommodation/Occupational Safety › Medical/First Aid
Issued 19 March 2002
Resolved
Provide adequate first aid kit in accordance with 46 CFR 180.71. LEGACY COMPONENT DESC: Medicine Chest
Due 27 March 2002
Resolved 27 March 2002
Resolution: Vessel operator provided adequate first aid kit.
Lifesaving
Issued 9 March 2001
Resolved
Provide (6) more adult life jackets for a total of 41 required, in accordance with 46 CFR 180.71.
Condition: Unknown
Due 6 April 2001
Resolved 6 April 2001
Navigation
Issued 9 March 2001
Resolved
Provide navigation chart, U.S. Coast Guard pilot excerpt, Coast Guard lightlist excerpt in accordance with 46 CFR 184.420.
Condition: Unknown
Due 6 April 2001
Resolved 6 April 2001
Accommodation/Occupational Safety
Issued 9 March 2001
Resolved
Provide MSD tank vent with 30 x 20 mesh screen in accordance with 33 CFR 159.95.
Condition: Unknown
Due 6 April 2001
Resolved 6 April 2001
Navigation
Issued 9 March 2001
Resolved
Prove proper operation of mast head light in accordance with 46 CFR 183.420and 72 COLREGS.
Condition: Unknown
Due 6 April 2001
Resolved 6 April 2001
Electrical
Issued 9 March 2001
Resolved
Replace globe on light fixture in forward accomodation space in accordance with 46 CFR 183.430.
Condition: Unknown
Due 6 April 2001
Resolved 6 April 2001
Construction/Loadline
Issued 9 March 2001
Resolved
Provide (4) fasteners for dead light covers in accordance with 46 CFR 179.350.
Condition: Unknown
Due 6 April 2001
Resolved 6 April 2001
Lifesaving
Issued 23 March 2000
Resolved
Provide 2 four foot long paddles for life float. IAW: 46 CFR 180.175.
Condition: Unknown
Due 31 March 2000
Resolved 31 March 2000
Electrical
Issued 23 March 2000
Resolved
Remove plastic wire hangers and zip ties that support electrical wires in engine space. Ensure electrical wires are supported by metallic type devices. IAW: 46 CFR 183.340 (b)(4).
Condition: Unknown
Due 31 March 2000
Resolved 31 March 2000
Electrical
Issued 23 March 2000
Resolved
Remove/repair dead end electrical wires and twist on type connectors located throughout vessel. IAW: 46 CFR 183.340 (g)(2).
Condition: Unknown
Due 31 March 2000
Resolved 31 March 2000
Documentation
Issued 9 April 1999
Resolved
Implement/log waste management plan and garbage log in vessel program.
Condition: Unknown
Due 29 April 1999
Resolved 29 April 1999
Documentation
Issued 9 April 1999
Resolved
Found drills and lifesaving equipment maintenance not to be documented/logged. Incorporate the logging/documenting of drills and lifesaving equipment maintenance in vessel program.
Condition: Unknown
Due 29 April 1999
Resolved 29 April 1999
Construction/Loadline
Issued 9 April 1999
Resolved
Ensure engineering space is vapor tight to coincide with fixed fire suppression system (fill in all holes in bulkhead).
Condition: Unknown
Due 29 April 1999
Resolved 29 April 1999
Documentation
Issued 9 April 1999
Resolved
Found FCC Safety Certificate to be out of date. Obtain current/up to date FCC Safety Certificate.
Condition: Unknown
Due 29 April 1999
Resolved 29 April 1999
Lifesaving
Issued 9 April 1999
Resolved
Provide two four foot long paddles for life float.
Condition: Unknown
Due 29 April 1999
Resolved 29 April 1999
Construction/Loadline
Issued 22 May 1995
Resolved
Provide a report with details of refastening of vessel; include type, size,and material of fasteners, areas of the vessel refastened, and all other pertinent information.
Condition: Unknown
Due 22 May 1995
Resolved 22 May 1995
Engineering
Issued 22 May 1995
Resolved
NOTED SIGNIFICANT CORROSION OF FUEL TANKS, ADEQUATELY TEST FUEL TANK AND/ORREPLACE AS ORIGINAL. ITEM TO BE COMPLETED TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR PRIOR TO ISSUANCE OF CERTIFICATE OF INSPECTION.
Condition: Unknown
Due 22 May 1995
Resolved 22 May 1995
Construction/Loadline
Issued 2 March 1995
Resolved
VESSEL IS PROHIBITED FROM OPERATING WITH MORE THAN SIX PASSENGERS ONBOARD UNTIL IT RECEIVES A COAST GUARD CREDIT DRYDOCK EXAMINATION AS REQUIRED BY 46 CFR 175.15-1(a).
Condition: Unknown
Due 2 March 1995
Resolved 2 March 1995
Lifesaving
Issued 1 July 1994
Resolved
REPLACE MISSING CHILD SIZE PFD.
Condition: Unknown
Due 13 July 1994
Resolved 13 July 1994
Documentation
Issued 1 July 1994
Resolved
PROVIDE EVIDENCE THAT OPERATORS HAVE A VALID FCC OPERATORS PERMIT.
Condition: Unknown
Due 13 July 1994
Resolved 13 July 1994
Fire Fighting
Issued 1 July 1994
Resolved
SERVICE ALL PORTABLE FIREFIGHTING EUIPMENT.
Condition: Unknown
Due 13 July 1994
Resolved 13 July 1994
Lifesaving
Issued 1 July 1994
Resolved
RENEW RING BUOY PERIPHERY LINE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 13 July 1994
Resolved 13 July 1994
Lifesaving
Issued 1 July 1994
Resolved
PLACE LIFEFLOATS IN A PROPER FLOAT FREE ARRANGEMENT._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 13 July 1994
Resolved 13 July 1994
Lifesaving
Issued 1 July 1994
Resolved
REPLACE DEFECTIVE SELF-ACTUATING WATERLIGHT ON LIFE FLOAT.
Condition: Unknown
Due 13 July 1994
Resolved 13 July 1994
Documentation
Issued 1 July 1994
Resolved
PROVIDE EVIDENCE OF BEING ENROLLED IN OR MAINTAINING A DRUG TESTING PROGRAM.
Condition: Unknown
Due 8 July 1994
Resolved 1 August 1994
Construction/Loadline
Issued 1 July 1994
Resolved
PROVE PROPER OPERATION OF FIXED BILGE SYSTEM.
Condition: Unknown
Due 13 July 1994
Resolved 13 July 1994
Construction/Loadline
Issued 1 July 1994
Resolved
PROVIDE PORTABLE HAND FIRE/BILGE PUMP.
Condition: Unknown
Due 13 July 1994
Resolved 13 July 1994
Documentation
Issued 1 July 1994
Resolved
VESSEL IS RESTRICTED TO NOT MORE THAN 20 MILES FROM A HARBOR OF SAFE REFUGEUNTIL A STABILITY TEST FOR EXPOSED WATERS IS PERFORMED IN THE PRESENCE OF AUSCG MARINE INSPECTOR.
Condition: Unknown
Due 17 November 1994
Resolved 1 August 1994
Documentation
Issued 1 July 1994
Resolved
PROVIDE EVIDENCE OF HAVING A VALID CERTIFICATE OF DOCUMENTATION
Condition: Unknown
Due 8 July 1994
Resolved 13 July 1994
Electrical
Issued 1 July 1994
Resolved
REEINSTALL ELECTRICAL GENERATOR EMERGENCY PULL CABLE.
Condition: Unknown
Due 1 July 1994
Resolved 1 July 1994
Lifesaving
Issued 1 July 1994
Resolved
REMOVE OR REPAIR STABILIZER PUMPS AND EQUIPMENT ON THE PORT AND STARBOARD SIDES OF THE MAIN ENGINE SPACE, FORWARD, AND MAKE AREA AVAILABLE FOR CLOSERVISUAL INSPECTION.
Condition: Unknown
Due 13 July 1994
Resolved 13 July 1994
Lifesaving
Issued 1 July 1994
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 13 July 1994
Resolved 13 July 1994
Lifesaving
Issued 1 July 1994
Resolved
RENEW PFD LIGHTS ON 32 ADULT AND 3 CHILD SIZE PFD's._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 13 July 1994
Resolved 13 July 1994
Engineering
Issued 13 October 1993
Resolved
PROVIDE HAND GUARDS OVER ALL PULLEYS OF STARBOARD ENGINE.
Condition: Unknown
Due 16 November 1993
Resolved 16 November 1993
Lifesaving
Issued 4 May 1992
Resolved
PROPERLY LABEL THE STOWAGE AREA FOR THE CHILDREN'S LIFE PRESERVERS.
Condition: Unknown
Due 4 May 1992
Resolved 4 May 1992
Navigation
Issued 4 May 1992
Resolved
PROVE PROPER OPERATION OF THE SINGLE SIDE BAND RADIO._x001C_
Condition: Unknown
Due 4 May 1992
Resolved 4 May 1992
Documentation
Issued 4 May 1992
Resolved
PROVIDE A CURRENT COPY OF A VALID FCC RADIO OPERATOR'S PERMIT.
Condition: Unknown
Due 4 May 1992
Resolved 4 May 1992
Documentation
Issued 4 May 1992
Resolved
PROVIDE ON BOARD THE VESSEL IT'S CERTIFICATE OF DOCUMENTATION.
Condition: Unknown
Due 4 May 1992
Resolved 4 May 1992
Accommodation/Occupational Safety
Issued 28 November 1990
Resolved
BRING THE MARINE HEADS INTO FULL COMPLIANCE WITH THE MARINE SANITATION DEVICE REGULATIONS (33 CFR PART 159).
Condition: Unknown
Due 28 November 1990
Resolved 28 November 1990
Documentation
Issued 28 November 1990
Resolved
CONDUCT A SIMPLIFIED STABILITY TEST IN ACCORDANCE WITH 46 CFR 171.030 FOR SERVICE ON EXPOSED WATERS.
Condition: Unknown
Due 28 November 1990
Resolved 28 November 1990
Electrical
Issued 28 November 1990
Resolved
LABEL ALL CIRCUIT BREAKER SWITCHES LOCATED IN THE LOCKER IN THE STARBOARD AFT SECTION OF THE MAIN CABIN.
Condition: Unknown
Due 28 November 1990
Resolved 28 November 1990
Electrical
Issued 28 November 1990
Resolved
PLACE A COVER PLATE ON THE 110 VOLT PLUG RECEPTACLE LOCATED IN THE LOCKER IN THE STARBOARD AFT SECTION OF THE MAIN CABIN.
Condition: Unknown
Due 28 November 1990
Resolved 28 November 1990
Lifesaving
Issued 24 October 1989
Resolved
REPLACE OUTDATED LIFE JACKET LIGHTS.
Condition: Unknown
Due 24 October 1989
Resolved 24 October 1989
Navigation
Issued 5 December 1988
Resolved
REPAIR AND DEMONSTRATE SATISFACTORY OPERATION OF SINGLE SIDE BAND RADIO. VESSEL RESTRICTED FROM CARRYING PASSENGERS BEYOND 20 MILES FROM A HARBOR OFSAFE REFUGE UNTIL RADIO IS SATISFACTORILY TESTED IN THE PRESENCE OF A COASTGUARD MARINE INSPECTOR.
Condition: Unknown
Due 5 December 1988
Resolved 5 December 1988
Navigation
Issued 2 December 1988
Resolved
CONDUCTED SATISFACTORY TEST OF VHF AND SSB RADIOS. TO BE WITNESSED BY MARINE INSPECTOR. VSL RESTRICTED FROM CARRYING PASSENGERS FURTHER THAN 1,000 FT FROM SHORE UNTIL COMPLETED.
Condition: Unknown
Due 2 December 1988
Resolved 2 December 1988