MAURY USCG vessel records Sign in
← All vessels

BRAVE

BRAVE is a 1970 industrial vessel. The Coast Guard has recorded 81 inspections since 1981, most recently in May 2009, along with 123 deficiencies and 2 casualty investigations between 2006 and 2009.

Records from 1981 to 2009. Most recent: inspection, 5 May 2009.

Built
1970
Last inspected
5 May 2009
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8758445 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDC7215
Flag
UNITED STATES
366675530, 367068020 (licence lapsed)
Maury page id
psix-46725

Inspections, by type

…with no type recorded28
Years with a record 28 calendar years (1981–2009)
The 81 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 17 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 1979.

Documentation record

Tonnage as PSIX records it2895 - Convention (Subpart B), Gross Ton
868 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDC7215MMSI 367068020 · cancelled · compulsorily equipped · granted 22 September 2005, cancelled 10 September 2015
WCR4658MMSI 366675530 · expired · compulsorily equipped · granted 28 April 2005, cancelled 11 July 2015 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 81

5 May 2009 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3467723
7 April 2009 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3448080
5 April 2009 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3446556
4 April 2009 Damage Survey · Examination of Repairs
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3449933
25 February 2009 Annual Inspection · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3427158
26 March 2008 Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3167523
29 June 2007 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2977435
5 June 2007 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2959301
24 May 2007 Internal Structural Exam · Hull Examination · COI Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2938883
14 August 2006 Deficiency Check · Damage Survey
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2747951
26 July 2006 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2726345
24 January 2006 Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2572329
1 November 2005 Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2526499
5 October 2005 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2508579
6 January 2005 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2269859
25 October 2004 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2227587
29 September 2004 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2209143
14 July 2004 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2184123
8 June 2004 Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2092245
9 September 2003 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1986560
19 March 2003 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1759524
14 May 2002 Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1626170
22 February 2002 Hull Examination · Internal Structural Exam · COI Inspection
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 1488487
31 January 2001 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1466758
11 August 2000 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 823735
29 July 2000 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 135190
20 July 2000 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 177160
23 February 2000 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1391251
12 December 1999 Damage Survey
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1426346
12 November 1999 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 11540
12 November 1999 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 124931
12 November 1999 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 810829
15 July 1999 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1096851
24 May 1999 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1064425
24 May 1999 Deficiency Check · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1418526
4 February 1999 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1450239
13 March 1998 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1106561
12 February 1998 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1414936
15 May 1997 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 756904
12 May 1997 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 195987
1 February 1997 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1377936
6 August 1996 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1092433
25 June 1996 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1090333
11 June 1996 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 643832
15 May 1996 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 212361
15 May 1996 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1412988
4 March 1996 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 78651
21 April 1995 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1169259
10 April 1995 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1438300
27 February 1995 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1162346
8 November 1994 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 659222
1 July 1994 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 59702
27 June 1994 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 643829
27 June 1994 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 643830
9 June 1994 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1323664
6 June 1994 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 16381
2 June 1994 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 74578
29 April 1994 Hull Examination · Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1379945
29 March 1994 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1165767
24 January 1994 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1439472
17 June 1993 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1356321
5 April 1993 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1435356
14 November 1992 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 135124
17 March 1992 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1263914
30 July 1991 Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1247196
14 May 1991 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 912615
9 April 1991 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1211472
22 May 1990 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1212742
4 May 1990 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 908149
11 May 1989 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1045144
3 May 1989 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1343367
14 April 1989 Hull Examination · Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 891736
18 February 1988 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1329795
15 September 1987 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1011914
1 May 1987 Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1027847
8 April 1986 COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1299703
13 January 1986 Credit Drydock
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1305043
1 April 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1288657
23 April 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1280294
27 April 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1278142
25 May 1981 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1272888

Deficiency record · 123

Stability › Watertight Integrity › General
Issued 4 April 2009 Resolved
A leak from one of the starboard fuel tanks filled up the lower starboard rub rail until it spilled out of a hole in the rub rail 40ft from the bow
Condition: Unknown
Action required: 705 - Other - as specified
Due 4 May 2009
Resolved 10 April 2009
Resolution: A 18" by 38" section of hull @ the starboard #3 wing fuel tank (170ft from the bow) was cropped & renewed and airtested to the satisfaction of the attending marine inspector.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 27 March 2009 Resolved
Submit updated Fire and Safety Control Plan.
Action required: 705 - Other - as specified
Due 27 April 2009
Resolved 5 May 2009
Resolution: Fire Control Plan submitted and approved. //s// [name withheld]2
Lifesaving › Rescue Boat › Embarkation/Disembarkation Capabilities
Issued 27 March 2009 Resolved
Ensure Rescue Boat is launched within 10 minutes to be witnessed by marine inspector.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 March 2009
Resolution: Rescue Boat was launched within 10 minutes and witnessed by a marine inspector.
Electrical › Electrical Distribution System (emergency) › Switchboard
Issued 27 March 2009 Resolved
On Emergency switchboard, non conductive mat must be placed on rear side.
Action required: 705 - Other - as specified
Due 27 April 2009
Resolved 30 March 2009
Resolution: On Emergency switchboard, a non conductive mat was placed on rear side.
Construction/Loadline › Structures › Deck Plating
Issued 26 July 2006 Resolved
During inspection, noted 2 holes in deck plating over bow rake. Subsequent UT gaugings noted severe wastage widespread. Required repairs to satisfaction of USCG and ABS (Classed HULL/LOADLINE).
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 August 2006
Engineering › Fuel Oil Service System › Valve, Control
Issued 26 July 2006 Resolved
Properly label direction of operation of fuel shutoffs on main deck.
Condition: Improper Installation
Due 26 August 2006
Resolved 11 August 2006
Electrical › Electrical Distribution System (service) › Junction Box
Issued 26 July 2006 Resolved
Provide enclosure for port side governor wire junction box on service generator.
Condition: Improper Installation
Due 26 August 2006
Resolved 11 August 2006
Lifesaving › Lifejacket/PFD (Type III) › Marking
Issued 26 July 2006 Resolved
Label lifejackets in portable quarters with vessel name.
Condition: Improper Installation
Due 26 August 2006
Resolved 11 August 2006
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 26 July 2006 Resolved
Provide metal trash cans with lids in engine room.
Condition: Improper Installation
Due 26 August 2006
Resolved 26 July 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 26 July 2006 Resolved
Provide metal wire banding support for all wiring outside conduit/raceways in living spaces and weather decks.
Condition: Improper Installation
Due 26 August 2006
Resolved 11 August 2006
Communications › Audible Communications › Horn/Whistle
Issued 26 July 2006 Resolved
Provide CO2 Alarm placards in machinery spaces.
Condition: Improper Installation
Due 26 August 2006
Resolved 11 August 2006
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 26 July 2006 Resolved
Fix exhaust leak in jet pump #1 prime mover.
Condition: Improper/Lack of Maintenance
Due 26 August 2006
Resolved 11 August 2006
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 26 July 2006 Resolved
Provide guards for rotating couplings on jet pump PTOs.
Condition: Improper Installation
Due 26 August 2006
Resolved 11 August 2006
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 26 July 2006 Resolved
Provide alternate activation instructions at each CO2 pull station.
Condition: Improper Installation
Due 26 August 2006
Resolved 11 August 2006
Fire Fighting › Self-contained Breathing Apparatus › Facepiece
Issued 1 November 2005 Resolved
SCBA has facepiece missing.
Action required: 705 - Other - as specified
Due 1 December 2005
Resolved 8 November 2005
Documentation › Certificates/Documents › FCC SSL
Issued 1 November 2005 Resolved
Bridge to Bridge Certificate expired.
Action required: 705 - Other - as specified
Due 1 December 2005
Resolved 8 November 2005
Fire Fighting › Fixed CO2 Fire Extinguishing System › Tanks
Issued 1 November 2005 Resolved
Fixed CO2 bottles are removed to be hydro tested.
Action required: 705 - Other - as specified
Due 1 December 2005
Resolved 8 November 2005
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 1 November 2005 Resolved
New operating instructions need to be completed for fixed CO2 instructions.
Action required: 705 - Other - as specified
Due 1 December 2005
Resolved 8 November 2005
Fire Fighting › Firemans Outfit › Lantern (Electric Safety Lamp)
Issued 1 November 2005 Resolved
FFE has a flashlight missing.
Action required: 705 - Other - as specified
Due 1 December 2005
Resolved 8 November 2005
Communications › Radio Communications › EPIRB
Issued 1 November 2005 Resolved
EPIRB battery needs to be replaced.
Action required: 705 - Other - as specified
Due 1 December 2005
Resolved 8 November 2005
Stability › Incline Test › General
Issued 8 June 2004 Resolved
Provide for approval, new stability calculations to include new portable quarters. Send calculations to the Marine Safety Center or ABS for final approval.
Due 6 August 2004
Resolved 25 October 2004
Electrical › Electrical Distribution System (service) › Cable
Issued 19 March 2003 Resolved
Replaced electrical cables on the engine room.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 19 March 2003
Resolved 19 March 2003
Engineering › Fuel Oil Service System › Hose
Issued 19 March 2003 Resolved
Replace fuel hoses on port main diesel engine. Old fuel hoses began to leak fuel.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 19 June 2003
Resolved 19 June 2003
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 19 March 2003 Resolved
Replace 5 Lifejackets with new ones.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 19 March 2003
Resolved 19 March 2003
Electrical › Electric Generation Source (emergency)
Issued 22 February 2002 Resolved
Repair/replace emergency generator automation alarm panel and install an audible alarm. Ref: 46CFR 112.50 LEGACY COMPONENT DESC: Panelboard
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 April 2002
Resolved 14 May 2002
Resolution: Witnessed panel.
Electrical › Electric Generation Source (service)
Issued 22 February 2002 Resolved
Replace emergency generator switchboard voltage meter. Ref: 111.30-25(B)(5) LEGACY COMPONENT DESC: Panelboard
Condition: Unknown
Action required: 705 - Other - as specified
Due 18 April 2002
Resolved 14 May 2002
Resolution: Witnessesed meter
Electrical › Electric Generation Source (service)
Issued 22 February 2002 Resolved
Install an automation alarm system for both ship service diesel generator (low lube and overspeed shutdowns, and hi jacket water alarm). Ref: 46CFR112.50
Condition: Unknown
Action required: 705 - Other - as specified
Due 18 April 2002
Resolved 14 May 2002
Resolution: Witnessed alarm
Electrical › Electric Generation Source (service)
Issued 22 February 2002 Resolved
Complete repairs on number one ship service diesel generator and test automation system once installed in the present of a Coast Guard Marine Inspector. LEGACY COMPONENT DESC: Generator
Condition: Unknown
Action required: 705 - Other - as specified
Due 18 April 2002
Resolved 14 May 2002
Resolution: Witnessed automation
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 22 February 2002 Resolved
Prodive an approved fixed fire extinguishing system plans to included 4 new bottles and piping. ( Marine Safety Center Approval).
Condition: Unknown
Action required: 705 - Other - as specified
Due 18 April 2002
Resolved 14 May 2002
Resolution: Confirmed witnessed by ABS.
Fire Fighting
Issued 12 December 1999 Resolved
All portable fire extinguisher and their corresponding stations must be numerically stenciled in accordance with the vessel's fire safety plan to the satisfaction of the attending marine inspector.
Condition: Unknown
Due 12 December 1999
Resolved 12 December 1999
Engineering
Issued 4 February 1999 Resolved
PRIOR TO COMPLETION OF NEXT HULL EXAM REPLACE WASTED ENGINE ROOMS VENTILATION DUCT WORK TO THE SATISFACTION OF THE ATTENDING CG MARINE INSPECTOR.
Condition: Unknown
Due 4 February 1999
Resolved 4 February 1999
Electrical
Issued 4 February 1999 Resolved
PRIOR TO COMPLETION OF NEXT HULL EXAM REMOVE DEAD ENDED CABLES AND WIRES INCONTROL ROOM TO THE SATISFACTION OF THE ATTENDING CG MARINE INSPECTOR.
Condition: Unknown
Due 4 February 1999
Resolved 4 February 1999
Accommodation/Occupational Safety
Issued 4 February 1999 Resolved
PRIOR TO COMPLETION OF NEXT HULL EXAM REPLACE ALL BROKEN SINKS AND REPIPE AS ORIGINAL TO THE SATISFACTION OF THE ATTENDING CG MARINE INSPECTOR.
Condition: Unknown
Due 4 February 1999
Resolved 4 February 1999
Accommodation/Occupational Safety
Issued 4 February 1999 Resolved
PRIOR TO COMPLETION OF NEXT HULL EXAM HARD WIRE ALL LAUNDRY ROOM EQUIPMENT TO THE SATISFACTION OF THE ATTENDING CG MARINE INSPECTOR.
Condition: Unknown
Due 4 February 1999
Resolved 4 February 1999
Accommodation/Occupational Safety
Issued 4 February 1999 Resolved
PRIOR TO COMPLETION OF NEXT HULL EXAM REMOVE ALL INOPERABLE LAUNDRY ROOM EQUIPMENT TO THE SATISFACTION OF THE ATTENDING CG INSPECTOR.
Condition: Unknown
Due 4 February 1999
Resolved 4 February 1999
Accommodation/Occupational Safety
Issued 4 February 1999 Resolved
PRIOR TO COMPLETION OF NEXT HULL EXAM VENT CLOTHES DRYERS TO DECK TO THE SATISFACTION OF THE ATTENDING CG MARINE INSPECTOR.
Condition: Unknown
Due 4 February 1999
Resolved 4 February 1999
Accommodation/Occupational Safety
Issued 4 February 1999 Resolved
PRIOR TO COMPLETION OF NEXT HULL EXAM REPIPE AIR CONDITIONER CONDENSOR RAW WATER PIPING AS NECESSARY TO THE SATISFACTION OF THE ATTENDING CG MARINE INSPECTOR.
Condition: Unknown
Due 4 February 1999
Resolved 4 February 1999
Electrical
Issued 4 February 1999 Resolved
PRIOR TO COMPLETION OF NEXT HULL EXAM REPLACE ALL EXTERIOR WELDING LEAD JUNCTION BOXES TO THE SATISFACTION OF THE ATTENDING CG MARINE INSPECTOR.
Condition: Unknown
Due 4 February 1999
Resolved 4 February 1999
Accommodation/Occupational Safety
Issued 4 February 1999 Resolved
PRIOR TO COMPLETION OF NEXT HULL EXAM REPLACE JOINER DOOR IN WAY OF OFFICE TO THE SATISFACTION OF THE ATTENDING CG MARINE INSPECTOR.
Condition: Unknown
Due 4 February 1999
Resolved 4 February 1999
Engineering
Issued 4 February 1999 Resolved
PRIOR TO COMPLETION OF NEXT HULL EXAM IN THE PRESENCE OF A CG MARINE INSPECTOR HYDRO TEST TO 1 1/2 MAWP OR REPLACE BOTH AIR REC'Rs IN STBD JET PUMP ROOM WITH ASME & ABS APPROVED AIR REC'Rs TO THE SATISFACTION OF ATTENDING CG MARINE INSPECTOR.
Condition: Unknown
Due 4 February 1999
Resolved 4 February 1999
Navigation
Issued 4 February 1999 Resolved
PRIOR TO COMPLETION OF NEXT HULL EXAM REPAIR OR REPLACE NAVIGATION LIGHT PANEL IN CONTROL ROOM TO THE SATISFACTION OF THE ATTENDING CG MARINE INSPECTOR.
Condition: Unknown
Due 4 February 1999
Resolved 4 February 1999
Electrical
Issued 4 February 1999 Resolved
PRIOR TO COMPLETION OF NEXT HULL EXAM INSTALL PERMANENT RECEPTICLES IN CONTROL ROOM FOR PORTABLE ELECTRONIC EQUIPMENT TO THE SATISFACTION OF THE ATTENDING CG MARINE INSPECTOR.
Condition: Unknown
Due 4 February 1999
Resolved 4 February 1999
Accommodation/Occupational Safety
Issued 4 February 1999 Resolved
PRIOR TO COMPLETION OF NEXT HULL EXAM REPLACE ALL BROKEN URINALS AND REPIPEAS ORIGINAL TO THE SATISFACTION OF THE ATTENDING CG MARINE INSPECTOR.
Condition: Unknown
Due 4 February 1999
Resolved 4 February 1999
Electrical
Issued 12 February 1998 Resolved
PLACE WIRE CONNECTION IN PAINT LOCKER INTO EXPLOSION PROOF JUNCTION BOX.
Condition: Unknown
Due 12 March 1998
Resolved 13 March 1998
Engineering
Issued 12 February 1998 Resolved
REPAIR/REPLACE EXHAUST LAGGING ON ENGINES THROUGHOUT BARGE, MAINLY JET PUMPENGINE.
Condition: Unknown
Due 12 March 1998
Resolved 13 March 1998
Electrical
Issued 12 February 1998 Resolved
REPAIR/REPLACE/INSTALL BLANKS FOR MISSING BREAKERS OR OPENINGS ON DISTRIBUTION PANELS AS FOLLOWS: ELP-203, DP-401, DP-402, ELP-201, LP-203 AND CHECK ALL OTHERS THROUGHOUT.
Condition: Unknown
Due 12 March 1998
Resolved 13 March 1998
Accommodation/Occupational Safety
Issued 1 February 1997 Resolved
REMOVE COMBUSTIBLE VENEERS IN CAPTAIN, INSPECTOR AND BARGE SUPERS QUARTERS.
Condition: Unknown
Due 1 February 1997
Resolved 1 February 1997
Documentation
Issued 15 May 1996 Resolved
PROVIDE A SHIPBOARD OIL POLLUTION EMERGENCY PLAN (SOPEP) APPROVED FOR THIS VESSEL.
Condition: Unknown
Due 15 May 1996
Resolved 15 May 1996
Lifesaving
Issued 15 May 1996 Resolved
PROVE PROPER OPERATION OF GENERAL ALARM BELLS IN UPPER QUARTERS, GALLEY & RIGGERS LOCKER TO THE SATISFACTION OF ATTENDING USCG MARINE INSPECTOR.
Condition: Unknown
Due 15 May 1996
Resolved 15 May 1996
Engineering
Issued 15 May 1996 Resolved
PROVIDE ON BOARD OIL TRANSFER PROCEDURE IN ACCORDANCE WITH 33 CFR 155.750.
Condition: Unknown
Due 15 May 1996
Resolved 15 May 1996
Documentation
Issued 15 May 1996 Resolved
PROVIDE DOCUMENTARY EVIDENCE OF COMPLIANCE WITH CHEMICAL TESTING PROGRAM WHICH INCLUDES ALL APPLICABLE PARTS OF 46 CFR 16.
Condition: Unknown
Due 15 May 1996
Resolved 15 May 1996
Engineering
Issued 15 May 1996 Resolved
PROVIDE EVIDENCE OF HYDRO TESTS FOR TWO 3" X 50' FUEL TRANSFER HOSES.
Condition: Unknown
Due 15 May 1996
Resolved 15 May 1996
Electrical
Issued 15 May 1996 Resolved
PROVIDE EVIDENCE OF EXPLOSION PROOF STUFFING TUBES PROPERLY INSTALLED ON PAINT LOCKER EXPLOSION PROOF LIGHT FIXTURES.
Condition: Unknown
Due 15 May 1996
Resolved 15 May 1996
Engineering
Issued 15 May 1996 Resolved
PROVIDE EVIDENCE OF ALL SEE-THRU FUEL FILTERS ON BOARD MEETING U.L. APPROVAL FOR MARINE USE.
Condition: Unknown
Due 15 May 1996
Resolved 15 May 1996
Engineering
Issued 10 April 1995 Resolved
PROVE PROPER OPERATION OF OILY WATER SEPARATOR TO THE SATISFACTION OF THE_x001C_ ATTENDING USCG MARINE INSPECTOR. VESSEL TO RETAIN ALL OILY WATER ON BOARD IN TANKS AND MAY NOT GO INTO FOREIGN WATERS UNTIL IOPP CERT IS ENDORSED.
Condition: Unknown
Due 10 April 1995
Resolved 10 April 1995
Accommodation/Occupational Safety
Issued 10 April 1995 Resolved
RENEW BOTH CRACKED WINDOWS ON AFT SIDE OF CONTROL ROOM.
Condition: Unknown
Due 10 April 1995
Resolved 10 April 1995
Documentation
Issued 10 April 1995 Resolved
PROVIDE ON BOARD VALID FCC STATION LICENSE.
Condition: Unknown
Due 10 April 1995
Resolved 10 April 1995
Documentation
Issued 10 April 1995 Resolved
PROVIDE ON BOARD OIL TRANSFER PROCEDURE IN ACCORDANCE WITH 33 CFR 155.750.
Condition: Unknown
Due 10 April 1995
Resolved 10 April 1995
Engineering
Issued 10 April 1995 Resolved
PROPERLY INSULATE EXHAUST PIPING OF STARBOARD GENERATOR.
Condition: Unknown
Due 10 April 1995
Resolved 10 April 1995
Electrical
Issued 29 April 1994 Resolved
REPAIR INPUT LINE SECTION OF CONDUIT TO #1 & 2 WELDING MACHINE JUNCTION BOX.
Condition: Unknown
Due 29 April 1994
Resolved 29 April 1994
Electrical
Issued 29 April 1994 Resolved
REPAIR OUTPUT LINE ON RHEOSTAT BOX FOR #1 & 2 WELDING MACHINES.
Condition: Unknown
Due 29 April 1994
Resolved 29 April 1994
Engineering
Issued 29 April 1994 Resolved
PROVE PROPER OPERATION OF REMOTE VENTILATION SHUTDOWN FOR CATERPILLAR ROOM.
Condition: Unknown
Due 29 April 1994
Resolved 29 April 1994
Engineering
Issued 29 April 1994 Resolved
REPLACE SIGHT GLASSES IN LUBE AND HYDRAULIC OIL TANKS WITH HEAT RESISTANT MATERIAL.
Condition: Unknown
Due 29 April 1994
Resolved 29 April 1994
Engineering
Issued 29 April 1994 Resolved
INSTALL GUARDS AROUND HYDRAULIC AND LUBE OIL TANK SIGHT GLASSES.
Condition: Unknown
Due 29 April 1994
Resolved 29 April 1994
Construction/Loadline
Issued 29 April 1994 Resolved
PROVE PROPER OPERATION OF OWS ALARM.
Condition: Unknown
Due 29 April 1994
Resolved 29 April 1994
Accommodation/Occupational Safety
Issued 29 April 1994 Resolved
REPAIR VENT DUCTING OVER PORT GENERATOR.
Condition: Unknown
Due 29 April 1994
Resolved 29 April 1994
Accommodation/Occupational Safety
Issued 29 April 1994 Resolved
REPAIR VENT DUCTING IN T.V. ROOM
Condition: Unknown
Due 29 April 1994
Resolved 29 April 1994
Electrical
Issued 29 April 1994 Resolved
PROVE PROPER OPERATION OF PORT GENERATOR OVERSPEED TRIP.
Condition: Unknown
Due 29 April 1994
Resolved 29 April 1994
Construction/Loadline
Issued 29 April 1994 Resolved
CROP AND RENEW HATCH COAMING OF ENGINE ROOM EMERGENCY ESCAPE HATCH.
Condition: Unknown
Due 29 April 1994
Resolved 29 April 1994
Deck/Cargo
Issued 29 April 1994 Resolved
INSTALL FACTORY TYPE FITTINGS ON FUEL LINES ON HYDRAULIC PUMP ENGINES.
Condition: Unknown
Due 29 April 1994
Resolved 29 April 1994
Accommodation/Occupational Safety
Issued 29 April 1994 Resolved
PROVE PROPER OPERATION OF REMOTE VENTILATION SHUTDOWN IN GENERATOR/LAUNDRY ROOM.
Condition: Unknown
Due 29 April 1994
Resolved 29 April 1994
Construction/Loadline
Issued 24 January 1994 Resolved
CLEAN, PREP, PAINT, ADJUST, REPAIR AND PROVIDE DOGGING WRENCHES FOR WTD AS NECESSARY.
Condition: Unknown
Due 31 January 1994
Resolved 31 January 1994
Documentation
Issued 24 January 1994 Resolved
PROVIDE STABILITY LTR REFLECTING LOADING RESTRICTIONS FOR BARGE AS OUTFITTED.
Condition: Unknown
Due 31 January 1994
Resolved 31 January 1994
Construction/Loadline
Issued 24 January 1994 Resolved
CROP AND RENEW #7 BAL, #7 INNER BOTTOM GOOSENECK VENT STAR. SIDE
Condition: Unknown
Due 31 January 1994
Resolved 31 January 1994
Electrical
Issued 24 January 1994 Resolved
CLEAR GROUND FAULTS MAIN AND EMER. SWITCHBOARDS.
Condition: Unknown
Due 31 January 1994
Resolved 31 January 1994
Construction/Loadline
Issued 24 January 1994 Resolved
CROP AND RENEW GOOSENECK VENTS AS NECESSARY.
Condition: Unknown
Due 31 January 1994
Resolved 31 January 1994
Engineering
Issued 24 January 1994 Resolved
RENEW BELL AND FLAME SCREEN FOR STAR. DIRTY OIL TANK VENT.
Condition: Unknown
Due 31 January 1994
Resolved 31 January 1994
Construction/Loadline
Issued 24 January 1994 Resolved
INSTALL CLOSER ON DOOR AT TOP OF LADDER FROM GALLEY.
Condition: Unknown
Due 31 January 1994
Resolved 31 January 1994
Documentation
Issued 24 January 1994 Resolved
PROVIDE WRITTEN DESIGNATION OF PERSON IN CHARGE.
Condition: Unknown
Due 31 January 1994
Resolved 31 January 1994
Fire Fighting
Issued 24 January 1994 Resolved
PROVIDE AAPPROVED FIRE HOSE NOZZLES FOR LOC.6,7, & 8.
Condition: Unknown
Due 31 January 1994
Resolved 31 January 1994
Deck/Cargo
Issued 24 January 1994 Resolved
PROVIDE WIRE ROPE CERTIFICATES FOR ACC. CARGO GEAR(HOISTING EQUIPMENT).
Condition: Unknown
Due 24 January 1994
Resolved 24 January 1994
Deck/Cargo
Issued 24 January 1994 Resolved
CONDUCT FIVE YEAR PROOF TEST ON CRANES AND CERTIFY ALL SLINGS, HOOKS, AND ASSOCIATED EQUIPMENT.
Condition: Unknown
Due 24 January 1994
Resolved 24 January 1994
Engineering
Issued 24 January 1994 Resolved
PROVE PROPER OPERATION OF JET PUMP AND WINCH PRIME MOVER SAFETIES; LOW L/O ALARMS, OVERSPEED TRIP.
Condition: Unknown
Due 7 February 1994
Resolved 7 February 1994
Engineering
Issued 24 January 1994 Resolved
MAKE PERMANENT REPAIRS TO #2 FUEL OIL TANK GOOSENECK VENT.
Condition: Unknown
Due 24 January 1994
Resolved 24 January 1994
Construction/Loadline
Issued 24 January 1994 Resolved
RENEW OR REPAIR EMER. GEN. RM DOOR.
Condition: Unknown
Due 31 January 1994
Resolved 31 January 1994
Accommodation/Occupational Safety
Issued 24 January 1994 Resolved
REPAIR HAND RAIL ON AFT ACCESS LADDER TO HELIPORT.
Condition: Unknown
Due 31 January 1994
Resolved 31 January 1994
Electrical
Issued 24 January 1994 Resolved
PROVIDE E-LIGHT FOR AFT LADDER MAIN DECK TO MACHINERY.
Condition: Unknown
Due 31 January 1994
Resolved 31 January 1994
Fire Fighting
Issued 24 January 1994 Resolved
REPAIR BRACKETS FOR #8,12 F/EXTS.
Condition: Unknown
Due 31 January 1994
Resolved 31 January 1994
Fire Fighting
Issued 24 January 1994 Resolved
REPOSITION FIRE HYDRANT #8 IAW 46CFR95.10-10(F).
Condition: Unknown
Due 31 January 1994
Resolved 31 January 1994
Engineering
Issued 24 January 1994 Resolved
PROPERLY SECURE HARD PIPING TO FUELING STATION FOR FORWARD WINCH.
Condition: Unknown
Due 31 January 1994
Resolved 31 January 1994
Lifesaving
Issued 24 January 1994 Resolved
RENEW SLINGS AND RING ON RESCUE BOAT; REPLACE OARS AND PAINTER LINE.
Condition: Unknown
Due 31 January 1994
Resolved 31 January 1994
Deck/Cargo
Issued 24 January 1994 Resolved
PROVIDE CRANE CERT.
Condition: Unknown
Due 31 January 1994
Resolved 31 January 1994
Lifesaving
Issued 17 June 1993 Resolved
SUBMIT A NEW FIRE ANDE SAFETY PLAN INDICATING LOCATION OF NEWLY INSTALLED FIRE STATION AND B V EXTINGUISHER TO THE [name withheld], LA.
Condition: Unknown
Due 17 June 1993
Resolved 17 June 1993
Lifesaving
Issued 17 June 1993 Resolved
PROVIDE AND INSTALL TWO (2) FIRE STATION NEAR MEANS OF ESCAPE FORM HELO PORT
Condition: Unknown
Due 17 June 1993
Resolved 17 June 1993
Accommodation/Occupational Safety
Issued 17 June 1993 Resolved
REPLACE 125 PSI RELIEF VALVE ON FWD AIR RECEIVER
Condition: Unknown
Due 17 June 1993
Resolved 17 June 1993
Engineering
Issued 17 June 1993 Resolved
CONDUCT TEST OF MAIN WINCH PRIME MOVERS (2EA) OVERSPEED TRIPS AND LOW LUBE OIL ALARMS
Condition: Unknown
Due 17 June 1993
Resolved 17 June 1993
Engineering
Issued 17 June 1993 Resolved
REMOVE EXISTING FUEL OIL RUBBER HOSES LEADING FROM BOTH FORE AND AFT DAY TANKS TO PRIME MOVER PIPING AND REPLACE WITH HARD PIPING
Condition: Unknown
Due 17 June 1993
Resolved 17 June 1993
Lifesaving
Issued 17 June 1993 Resolved
PROVIDE AND INSTALL A SECOND MEAN OF ESCAPE FROM HELO PORT.
Condition: Unknown
Due 17 June 1993
Resolved 17 June 1993
Lifesaving
Issued 17 June 1993 Resolved
PROVIDE AND INSTALL ONE B V SEMI PORTABLE FIRE EXT. FOR HELO PORT
Condition: Unknown
Due 17 June 1993
Resolved 17 June 1993
Accommodation/Occupational Safety
Issued 17 June 1993 Resolved
REPAIR REAR GUARD (END BELL) ON REDD FOXX TREATMENT SYSTEM MOTOR.
Condition: Unknown
Due 17 June 1993
Resolved 17 June 1993
Electrical
Issued 17 June 1993 Resolved
CHANGE OUT VALVE ON DAY TANK FOR EMERGENCY GENERATOR FUEL OIL AND STENCIL EMERGENCY SHUTOFF WITH ARROW FOR DIRECTION.
Condition: Unknown
Due 17 June 1993
Resolved 17 June 1993
Accommodation/Occupational Safety
Issued 17 June 1993 Resolved
REPAIR BULKHEAD IN CONTROL HOUSE PORT SIDE AFT.
Condition: Unknown
Due 17 June 1993
Resolved 17 June 1993
Accommodation/Occupational Safety
Issued 17 June 1993 Resolved
REPAIR AND INSTALL LOUVERS IN GALLEY VENT AND INSTALL DOGS.
Condition: Unknown
Due 17 June 1993
Resolved 17 June 1993
Deck/Cargo
Issued 17 June 1993 Resolved
PROVIDE EVIDENCE OF CRANE TESTING
Condition: Unknown
Due 17 June 1993
Resolved 17 June 1993
Engineering
Issued 17 June 1993 Resolved
REPLACE FUEL OIL HOSES ON ALL WINCH PRIME MOVERS (3) EA WITH PROPER HOSES AND FITTING
Condition: Unknown
Due 17 June 1993
Resolved 17 June 1993
Engineering
Issued 17 June 1993 Resolved
PROVIDE AND INSTALL EXHAUST LAGGING ON ALL WINCH PRIME MOVERS (3 EA)
Condition: Unknown
Due 17 June 1993
Resolved 17 June 1993
Electrical
Issued 17 June 1993 Resolved
REPAIR ELECTRICAL STUFFING TUBES ON DECK AND IN BULKHEAD WERE ELECTRICAL WIRES HAVE PULL OUT
Condition: Unknown
Due 17 June 1993
Resolved 17 June 1993
Electrical
Issued 17 June 1993 Resolved
RELAMP ALL ELECTRICAL LIGHT FIXTURE AND TEST EMERGENCY LIGHTS, MARK ALL EMERGENCY LIGHTS AS NEEDED.
Condition: Unknown
Due 17 June 1993
Resolved 17 June 1993
Construction/Loadline
Issued 17 June 1993 Resolved
PROVIDE AND INSTALL MISSING DOG ON HATCH LEADING TO GENERATOR ROOM
Condition: Unknown
Due 17 June 1993
Resolved 17 June 1993
Construction/Loadline
Issued 17 June 1993 Resolved
REPAIR/REPLACE CO2 WATERTIGHT DOOR BOTTOM INTER LIP WERE ERODED
Condition: Unknown
Due 17 June 1993
Resolved 17 June 1993
Electrical
Issued 17 June 1993 Resolved
CONDUCT TEST OF EMERGENCY GENERATOR PRIME MOVER OVERSPEED TRIP, LOW LUBE OIL AND HIGH TEMP ALARMS
Condition: Unknown
Due 17 June 1993
Resolved 17 June 1993
Engineering
Issued 17 June 1993 Resolved
CONDUCT TEST OF JET PUMP PRIME MOVERS (2EA) OVERSPEED TRIPS AND LOW LUBE OIL ALARMS
Condition: Unknown
Due 17 June 1993
Resolved 17 June 1993
Electrical
Issued 9 April 1991 Resolved
PROVIDE BLANKS WHERE MISSING IN PANELBOARDS ELP-201 AND EDP-201 (EMG GEN _x001C_ ROOM)
Condition: Unknown
Due 9 April 1991
Resolved 9 April 1991
Fire Fighting
Issued 9 April 1991 Resolved
RESUBMIT FIRE CONTROL PLAN TO REPRESENT EQUIPMENT ON BOARD OR MAKE APPLICABLE MODIFICATIONS IAW PRESENT APPROVED FIRE CONTROL PLAN.
Condition: Unknown
Due 9 April 1991
Resolved 9 April 1991
Accommodation/Occupational Safety
Issued 9 April 1991 Resolved
REPLACE GASKETS ON ALL DECK VENT CLOSURES WHERE NEEDED.
Condition: Unknown
Due 9 April 1991
Resolved 9 April 1991
Lifesaving
Issued 9 April 1991 Resolved
PROVIDE SERVICING AND PROVIDE COPIES OF THE SERVICING REPORTS FOR THE THREE(3) REQUIRED LIFERAFTS ON BOARD._x001C_
Condition: Unknown
Due 9 April 1991
Resolved 9 April 1991
Construction/Loadline
Issued 9 April 1991 Resolved
MAKE THE VESSEL AVAILABLE FOR A CREDIT DRYDOCK INSPECTION AS SOON AS POSSIBLE.
Condition: Unknown
Due 9 April 1991
Resolved 9 April 1991
Documentation
Issued 9 April 1991 Resolved
PROVIDE ON BOARD A VALID CERTIFICATE OF FINANCIAL RESPONSIBILITY AND PROVIDE COPY OF SAME TO THE COGNIZANT OCMI.
Condition: Unknown
Due 9 April 1991
Resolved 9 April 1991
Fire Fighting
Issued 4 May 1990 Resolved
REPAIR OR REPLACE PRESSURE GAUGE ON MAIN FIRE PUMP.(46 CFR 95.10-5)
Condition: Unknown
Due 4 May 1990
Resolved 4 May 1990
Deck/Cargo
Issued 14 April 1989 Resolved
DEMONSTRATE PROPER OPERATION OF REACH RODS IN WAY OF BOW COMPARTMENT BILGE SUCTION.
Condition: Unknown
Due 14 April 1989
Resolved 14 April 1989
Deck/Cargo
Issued 14 April 1989 Resolved
TEST PUMP ENGINE EMERGENCY SHUT DOWN. 46 CFR 32.50-35
Condition: Unknown
Due 14 April 1989
Resolved 14 April 1989
Electrical
Issued 1 May 1987 Resolved
PROVIDE NON-CONDUCTING HANDRAILS FOR THE FRONT OF THE EMERGENCY GENERATOR SWITCHBOARD.
Condition: Unknown
Due 1 May 1987
Resolved 1 May 1987
Electrical
Issued 1 May 1987 Resolved
PROVIDE BOTH FRONT AND REAR NON-CONDUCTING HANDRAILS FOR THE MAIN GENERATORSWITCHBOARD.
Condition: Unknown
Due 1 May 1987
Resolved 1 May 1987

Casualty record · 2

16 December 2006Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 2 injured · activity 2841610
5 April 2009Routine · role: Acknowledged Pollution Source · activity 3446556
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record