16 June 2025
Administrative Inspection
Administrative · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 8177969
14 October 2024
Administrative Inspection
Administrative · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 8021085
27 September 2023
Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7799692
2 August 2022
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7527865
7 July 2022
Administrative Inspection
Administrative · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7499695
6 May 2021
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7193333
6 May 2021
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7193369
19 April 2021
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7178397
21 December 2020
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7114756
3 October 2019
Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6827820
8 August 2019
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6777126
8 July 2019
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6759470
5 September 2017
Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6265003
15 August 2017
Type not recorded
No type recorded · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 6270012
21 February 2017
Type not recorded
No type recorded · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 6090300
15 February 2017
In-Service Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6109714
24 May 2016
Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5885878
10 May 2016
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5899929
28 April 2016
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5864621
28 April 2016
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5864630
25 April 2016
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5892867
12 February 2016
Deficiency Check · In-Service Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5814474
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 May 2021
Resolved
In order to maintain system integrity, each individual electrical installation in a hazardous location must complyspecifically with incorporated references. Found 1 explosion proof light with a cracked housing exposing wires in a haz location.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 May 2021
Resolved 7 May 2021
Resolution: Replaced light with new light.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 October 2019
Resolved
THE EMERGENCY EQUIPMENT PROVIDED SHALL BE MAINTAINED IN GOOD CONDITION AT ALL TIMES. THE EDG ENCLOSURE HAS SERVERAL WASTED AREAS THAT WILL PREVENT PROPER USAGE OF FIXED CO2 SYSTEM.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2019
Resolved 26 October 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 October 2019
Resolved
THE EMERGENCY EQUIPMENT PROVIDED SHALL BE MAINTAINED IN GOOD CONDITION AT ALL TIMES. TWO OF THE EDG SRING ACTUATED LOUVERS WERE BROKEN.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2019
Resolved 26 October 2019
Electrical › Electrical Distribution System (service) › Wiring
Issued 16 February 2017
Resolved
Multiple electrical cables on the cellar desk were missing cable supports and needed to be properly secured.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 March 2017
Resolved 24 February 2017
Resolution: Vessel's crew installed wire supports and provided pictures to the Coast Guard.
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 25 May 2016
Resolved
The pin on the shackle holding the straps and hydrostatic release to the frame had backed out.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 May 2016
Resolved 25 May 2016
Resolution: Vessel's crew tightened pin and wire tied it into place.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 25 May 2016
Resolved
Exterior door from galley has a broken and disconnected closure device and the door does not latch.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 June 2016
Resolved 1 June 2016
Resolution: Rig's crew installed new closure device and latch and emailed pictures to the Coast Guard of repairs.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 25 May 2016
Resolved
Mulitiple emergency lights about the rig had burnt out bulbs.
Condition: Improper/Lack of Maintenance
Due 1 June 2016
Resolved 1 June 2016
Resolution: Rig's crew replaced burnt out light bulbs and provided pictures to the Coast Guard of new bulbs energized and burning brightly.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 25 May 2016
Resolved
Multiple lifejacket boxes had faded and unreadable lables. Multiple liferings did not have proper placards at their location.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 June 2016
Resolved 1 June 2016
Resolution: Rig's crew installed proper lables and placards and provided pictures to Coast Guard.
Electrical › Electrical Distribution System (service) › Switch
Issued 25 May 2016
Resolved
A switchbox on the south production deck has rusted off its mount and is free hanging by the cable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 June 2016
Resolved 1 June 2016
Resolution: Rig's crew remounted the switchbox and provided pictures to the Coast Guard.