HOOVER DIANA is a 1999 industrial vessel. The Coast Guard has recorded 76 inspections since 1997, most recently in June 2025, along with 71 deficiencies and 4 casualty investigations between 2004 and 2009.

Records from 1997 to 2025. Most recent: inspection, 16 June 2025.

Built
1999
Last inspected
16 June 2025
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WQZ430
467291
Flag
UNITED STATES
—
Maury page id
psix-467291

Inspections, by type

…with no type recorded24
Years with a record 23 calendar years (1997–2025)
The 76 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it34434 - Regulatory (Subpart C or D), Gross Ton
32746 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 76

16 June 2025 Administrative Inspection
Administrative · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 8177969
14 October 2024 Administrative Inspection
Administrative · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 8021085
27 September 2023 Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7799692
2 August 2022 Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7527865
7 July 2022 Administrative Inspection
Administrative · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7499695
6 May 2021 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7193333
6 May 2021 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7193369
19 April 2021 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7178397
21 December 2020 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7114756
3 October 2019 Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6827820
8 August 2019 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6777126
8 July 2019 Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6759470
5 September 2017 Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6265003
15 August 2017 Type not recorded
No type recorded · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 6270012
21 February 2017 Type not recorded
No type recorded · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 6090300
15 February 2017 In-Service Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6109714
24 May 2016 Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5885878
10 May 2016 Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5899929
28 April 2016 Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5864621
28 April 2016 Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5864630
25 April 2016 Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5892867
12 February 2016 Deficiency Check · In-Service Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5814474
5 July 2012 Internal Structural Exam · Underwater Inspection in lieu of Drydock · Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4368464
5 July 2011 Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4069696
17 November 2008 Initial Construction-Excluding Oversight · Administrative Inspection · Plan Review (Other than "T") · Welding Related Inspections Qualification Testing
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3366109
21 July 2008 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3274772
28 May 2008 Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3226130
15 October 2007 Underwater Inspection in lieu of Drydock
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3707100
15 May 2007 Annual Inspection · In-Service Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2928011
13 April 2007 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3909787
24 May 2006 Annual Inspection · MTSA Verification
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2671969
8 March 2006 Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2598442
22 July 2005 Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2435722
10 May 2005 COI Inspection · MTSA Verification
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2354396
15 November 2004 Administrative Inspection
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2241423
15 October 2004 Internal Structural Exam · In-Service Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2220275
15 September 2004 MTSA Verification · Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2190377
19 August 2004 Annual Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2161909
15 August 2004 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2178523
10 August 2004 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2162323
2 August 2004 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2178509
17 May 2004 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2087860
16 September 2003 Administrative Inspection
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1906332
29 July 2003 Deficiency Check · Annual Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1855753
15 January 2003 Construction Oversight · Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1730807
21 October 2002 In-Service Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1714276
11 July 2002 Deficiency Check · In-Service Inspection · Periodic Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1643670
26 October 2001 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 10558
17 August 2001 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1070887
24 July 2001 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 77133
26 June 2001 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1068127
31 May 2001 Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1443199
4 January 2001 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 825325
28 September 2000 Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1053785
15 August 2000 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1052840
17 July 2000 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1051479
18 June 2000 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 23419
25 May 2000 Initial Certification · Initial Construction-Excluding Oversight
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1456853
9 May 2000 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 818167
25 April 2000 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 756994
11 April 2000 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 209835
22 November 1999 Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 810077
10 November 1999 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 812816
21 June 1999 Type not recorded
No type recorded · Activities Europe · Activity 1365250
26 May 1999 Type not recorded
No type recorded · Activities Europe · Activity 1372636
28 April 1999 Type not recorded
No type recorded · Activities Europe · Activity 1365182
6 April 1999 Type not recorded
No type recorded · Activities Europe · Activity 1459491
16 March 1999 Type not recorded
No type recorded · Activities Europe · Activity 1402807
18 February 1999 Administrative
Administrative · Activities Europe · Activity 1129215
10 November 1998 Type not recorded
No type recorded · Activities Europe · Activity 1390864
7 October 1998 Type not recorded
No type recorded · Activities Europe · Activity 1470477
28 July 1998 Initial Construction-Excluding Oversight
Physical examination · Activities Europe · Activity 1424624
5 May 1998 Initial Construction-Excluding Oversight
Physical examination · Activities Europe · Activity 1364724
13 March 1998 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 803428
5 February 1998 Type not recorded
No type recorded · Activities Europe · Activity 1381117
9 December 1997 Initial Construction-Excluding Oversight
Physical examination · Activities Europe · Activity 1116825

Deficiency record · 71

09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 May 2021 Resolved
In order to maintain system integrity, each individual electrical installation in a hazardous location must complyspecifically with incorporated references. Found 1 explosion proof light with a cracked housing exposing wires in a haz location.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 May 2021
Resolved 7 May 2021
Resolution: Replaced light with new light.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 October 2019 Resolved
THE EMERGENCY EQUIPMENT PROVIDED SHALL BE MAINTAINED IN GOOD CONDITION AT ALL TIMES. THE EDG ENCLOSURE HAS SERVERAL WASTED AREAS THAT WILL PREVENT PROPER USAGE OF FIXED CO2 SYSTEM.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2019
Resolved 26 October 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 October 2019 Resolved
THE EMERGENCY EQUIPMENT PROVIDED SHALL BE MAINTAINED IN GOOD CONDITION AT ALL TIMES. TWO OF THE EDG SRING ACTUATED LOUVERS WERE BROKEN.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2019
Resolved 26 October 2019
Electrical › Electrical Distribution System (service) › Wiring
Issued 16 February 2017 Resolved
Multiple electrical cables on the cellar desk were missing cable supports and needed to be properly secured.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 March 2017
Resolved 24 February 2017
Resolution: Vessel's crew installed wire supports and provided pictures to the Coast Guard.
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 25 May 2016 Resolved
The pin on the shackle holding the straps and hydrostatic release to the frame had backed out.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 May 2016
Resolved 25 May 2016
Resolution: Vessel's crew tightened pin and wire tied it into place.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 25 May 2016 Resolved
Exterior door from galley has a broken and disconnected closure device and the door does not latch.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 June 2016
Resolved 1 June 2016
Resolution: Rig's crew installed new closure device and latch and emailed pictures to the Coast Guard of repairs.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 25 May 2016 Resolved
Mulitiple emergency lights about the rig had burnt out bulbs.
Condition: Improper/Lack of Maintenance
Due 1 June 2016
Resolved 1 June 2016
Resolution: Rig's crew replaced burnt out light bulbs and provided pictures to the Coast Guard of new bulbs energized and burning brightly.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 25 May 2016 Resolved
Multiple lifejacket boxes had faded and unreadable lables. Multiple liferings did not have proper placards at their location.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 June 2016
Resolved 1 June 2016
Resolution: Rig's crew installed proper lables and placards and provided pictures to Coast Guard.
Electrical › Electrical Distribution System (service) › Switch
Issued 25 May 2016 Resolved
A switchbox on the south production deck has rusted off its mount and is free hanging by the cable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 June 2016
Resolved 1 June 2016
Resolution: Rig's crew remounted the switchbox and provided pictures to the Coast Guard.
Fire Fighting › Nozzles › Type
Issued 5 July 2011 Resolved
Provide proper foam discharge nozzles for helo deck foam hose reels -- discharge devices must be part of USCG type-approved system.
Due 22 August 2011
Resolved 1 September 2011
Construction/Loadline › Structures › Superstructure
Issued 5 July 2011 Resolved
Repair/replace wasted top on paint locker on production deck.
Condition: Improper/Lack of Maintenance
Due 22 August 2011
Resolved 1 September 2011
Electrical › Electrical Distribution System (service) › Junction Box
Issued 5 July 2011 Resolved
Replace cracked class 1, div 1 electrical jucntion box beside FRC (Fast Rescue Craft).
Condition: Damaged By Earlier Event
Due 22 August 2011
Resolved 1 September 2011
Fire Fighting › Fire Hydrants › Condition
Issued 5 July 2011 Resolved
Replace supply valve and eductor valve on hose reel #27
Condition: Improper/Lack of Maintenance
Due 22 August 2011
Resolved 1 September 2011
Fire Fighting › Fire Hydrants › Condition
Issued 5 July 2011 Resolved
Replace supply valve on hose reel #26.
Condition: Improper/Lack of Maintenance
Due 22 August 2011
Resolved 1 September 2011
Fire Fighting › Fire Hydrants › Condition
Issued 5 July 2011 Resolved
Replace leaking swivel joints on hose reels #19 & 20.
Condition: Improper/Lack of Maintenance
Due 22 August 2011
Resolved 1 September 2011
Fire Fighting › Fire Hydrants › Condition
Issued 5 July 2011 Resolved
Replace wasted eductor valve on hose reel #24.
Condition: Improper/Lack of Maintenance
Due 22 August 2011
Resolved 1 September 2011
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 28 May 2008 Resolved
Renew safety markings on helicopter platform.
Action required: 705 - Other - as specified
Due 28 August 2008
Resolved 21 July 2008
Resolution: Helideck markings were repainted.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 24 May 2006 Resolved
Replace expired eye wash bottles in Battery Room 804.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 June 2006
Resolved 24 May 2006
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 24 May 2006 Resolved
Renew wasted/holed base of safety shower #9.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 June 2006
Resolved 24 May 2006
Fire Fighting › Fire Main › Condition
Issued 24 May 2006 Resolved
Renew wasted flange bolts on fire water piping accross from turbine 513 (next to diesel fire pump day tank) - 6" clay valve PCV-338-3.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 June 2006
Resolved 24 May 2006
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 24 May 2006 Resolved
Lifeboats and rescue boat have not been launched since January 2006. Ensure lifeboats and rescue boat are launched at intervals not to exceed those prescribed in 46 CFR 109.213(d).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 June 2006
Resolved 24 May 2006
Lifesaving › Lifeboat Equipment › Binnacle/Compass
Issued 24 May 2006 Resolved
Repair magnetic compass for #1 lifeboat.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 June 2006
Resolved 24 May 2006
Accommodation/Occupational Safety › Potable Water System › General
Issued 24 May 2006 Resolved
Provide proof of NSF mark for Fiberbond potable water manifold on spar deck. Piping does not bear the mark of the National Sanitation Foundation Testing Laboratory per 46 CFR 56.60-25(a)(4).
Condition: Unknown
Action required: 705 - Other - as specified
Due 31 July 2006
Resolved 24 May 2006
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 10 May 2005 Resolved
Renew expired helideck burn kit, and all other expired medications in first aid kits throughout installation.
Action required: 705 - Other - as specified
Due 20 June 2005
Resolved 30 May 2005
Resolution: Received invoice/receipt from OIM for new burn kit.
Deck/Cargo › Cargo Heating › General
Issued 10 May 2005 Resolved
Make permanent repairs to leak in pressure demand valve 145-2 for high temp hot oil bypass system.
Action required: 705 - Other - as specified
Due 20 June 2005
Resolved 23 May 2005
Resolution: Received OIM certification that valve was repaired.
Documentation › Safety/Response Plans/Programs › General Arrangement Plans
Issued 10 May 2005 Resolved
Provide updated area classification plan to reflect removal of drilling package.
Action required: 705 - Other - as specified
Due 20 June 2005
Resolved 16 June 2005
Resolution: Received report of 6/16/2005 from [name withheld] attesting to submittal of area classification drawings to the MMS Lake Jackson District, ABS, and USCG MSC via UPS overnight.
Lifesaving › Lifeboat › Markings
Issued 10 May 2005 Resolved
Restore faded international orange color for lifeboats as original per manufacturer instructions.
Action required: 705 - Other - as specified
Due 20 June 2005
Resolved 3 July 2005
Resolution: OIM [name withheld] email of 7/3/2005 inc. digital photos evidenced satisfactory restoration of color/finish per [name withheld] procedures.
Engineering › Compressed Air System (start air) › Receiver/Bottle
Issued 10 May 2005 Resolved
Provide manufacturer data reports (U1A) for two new pressure vessels on west crane.
Action required: 705 - Other - as specified
Due 20 June 2005
Resolved 2 June 2005
Resolution: U1As received this date.
Communications › Radio Communications › EPIRB
Issued 10 May 2005 Resolved
Renew expired NOAA registration and hydrostatic releases for lifeboat EPIRBs.
Action required: 705 - Other - as specified
Due 27 May 2005
Resolved 27 May 2005
Resolution: Received documentation showing that NOAA registrations expire 18DEC05, and invoices for receipt of new hydrostatic releases.
Lifesaving › Lifeboat › Embarkation/Disembarkation Capabilities
Issued 10 May 2005 Resolved
Remove or properly maintain lifeboat #1 and associated equipment/davit/falls (excess installation).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 June 2005
Resolved 11 June 2005
Resolution: OIM [name withheld] email report of 6/20/2005 verified that lifeboat was removed on 6/11/2005.
Engineering › Compressed Air System (start air) › Piping
Issued 10 May 2005 Resolved
Replace cracked 2 inch hose on west crane (air service).
Action required: 705 - Other - as specified
Due 20 June 2005
Resolved 30 May 2005
Resolution: Hose installed
Personnel › Manning/Qualifications › Citizenship Requirements
Issued 10 May 2005 Resolved
For non-US citizens employed on installation, provide evidence of H2B Visas, exemption under 33 CFR 141.20, or OCMI determination under 33 CFR 141.15.
Action required: 705 - Other - as specified
Due 27 May 2005
Resolved 27 May 2005
Resolution: Received request for determination this date.
Fire Fighting › Fire Main › Condition
Issued 10 May 2005 Resolved
Renew patched firewater piping under helideck as original or with other suitable metallic piping.
Action required: 705 - Other - as specified
Due 31 August 2005
Resolved 28 September 2005
Resolution: Copper nickel piping renewal plans approved by MSC 7/22/2005. Piping renewal confirmed to be completed via email from [name withheld] on 9/28/2005.
Engineering › Pressure Vessel › Relief Valve
Issued 10 May 2005 Resolved
Provide safety relief valve - not to exceed 100 psi - for new water heater installation to qualify for exemptions under 46 CFR 54.01-15.
Action required: 705 - Other - as specified
Due 27 May 2005
Resolved 25 May 2005
Resolution: Received invoice for new relief valve.
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 10 May 2005 Resolved
Provide documentation with evidence of approval for hole in deck of switchboard room in utility house above quarters. Hole is open to annular above drop ceiling for upper level of accommodations.
Action required: 705 - Other - as specified
Due 31 August 2005
Resolved 8 November 2005
Resolution: Damper installation approved for this arrangement in MSC letter Serial # C1-0506138 this date.
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 15 November 2004 Resolved
Provide an A class boundaries for the space containing the emergency source of power as required by 46 CFR 108.139.
Action required: 705 - Other - as specified
Due 1 December 2004
Resolved 30 November 2004
Resolution: Bret Motaruli of ABS submitted request for equivalency to [name withheld] of MSC this date.
Electrical › Electric Generation Source (emergency) › Generator
Issued 15 November 2004 Resolved
Locate the emergency power source (generator) and emergency switchboard in the same space as required by 46 CFR 112.05-5(h).
Action required: 705 - Other - as specified
Due 1 December 2004
Resolved 30 November 2004
Resolution: Bret Motaruli of ABS submitted request for equivalency to [name withheld] of MSC this date.
Documentation › Safety/Response Plans/Programs › General Arrangement Plans
Issued 19 August 2004 Resolved
Update lifesaving equipment arrangement plan to reflect removal of two (2) lifeboats.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 September 2004
Resolved 21 August 2004
Resolution: Certified to have been corrected by OIM [name withheld] via email of 9/17/2004
Lifesaving › Launching Appliances › Falls
Issued 19 August 2004 Resolved
Renew rescue boat fall prior to 31AUG04.
Action required: 705 - Other - as specified
Due 31 August 2004
Resolved 30 August 2004
Resolution: Certified to have been corrected by OIM [name withheld] via email of 9/17/2004
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 19 August 2004 Resolved
Renew diesel fuel hoses at lifeboat fuel stations.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 September 2004
Resolved 1 September 2004
Resolution: Certified to have been corrected via email from OIM [name withheld] of 9/17/2004
Fire Fighting › Structural - A Class Divisions › Windows
Issued 19 August 2004 Resolved
Provide evidence that plexiglass window on emergency generator enclosure meets A-class structural fire protection boundary. * 9/30/2004 - Vessel granted 30-day extension to resolve this discrepancy.**During meeting of 10/28/2004, CORMS CID granted extension to 12/01/2004 to resolve.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 December 2004
Resolved 15 November 2004
Resolution: Vessel operator advised that entire enclosure is not A-class. Closing this requirement to provide documentation and re-issuing requirements for (1) A-class enclosure and (2) emergency power source and switchboard to be located in the same space.
Lifesaving › Lifeboat › Propulsion Casing/Protection
Issued 19 August 2004 Resolved
Prove proper operation of tachometer for lifeboat #1.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 September 2004
Resolved 20 August 2004
Resolution: Confirmed via email
Lifesaving › Buoyant Smoke Signals › General
Issued 19 August 2004 Resolved
Provide evidence of expiration dates for self-activating smoke signals (on two quick release lifebuoys) or renew these smoke signals with those approved under 46 CFR 160.157.
Condition: Unknown
Action required: 705 - Other - as specified
Due 26 August 2004
Resolved 28 August 2004
Electrical › Electrical Distribution System (service) › Switch
Issued 19 August 2004 Resolved
Prove proper operation of loss-of-pressure alarm for 805 building which opens into Class 1, Div 2 location IAW 46 CFR 111.105-33
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 September 2004
Resolved 15 September 2004
Electrical › Electric Generation Source (service) › Generator
Issued 19 August 2004 Resolved
Prove operation of reverse-power relays for main ship's service generators.
Action required: 705 - Other - as specified
Due 19 September 2004
Resolved 15 September 2004
Fire Fighting › Fixed Fire Detection System › Flame Detectors
Issued 19 August 2004 Resolved
Repair/renew UV/IR detector watching 513 turbine enclosure.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 August 2004
Resolved 20 August 2004
Resolution: Confirmed via email.
Documentation › Certificates/Documents › FCC SSL
Issued 19 August 2004 Resolved
Renew FCC Marine Radio Station License prior to 31AUG04.
Action required: 705 - Other - as specified
Due 31 August 2004
Resolved 15 September 2004
Documentation › Certificates/Documents › Certificate of Inspection
Issued 19 August 2004 Resolved
Complete credit hull exam (ISIP) prior to 04NOV04. This must be completed to the satisfaction of [name withheld] to continue operation after 04NOV04.
Action required: 705 - Other - as specified
Due 4 November 2004
Resolved 18 October 2004
Electrical › Electric Generation Source (emergency) › Panelboard
Issued 29 July 2003 Resolved
Prove proper operation of indicator flag for reverse power relay board in EMCC.
Action required: 705 - Other - as specified
Due 20 August 2003
Resolved 7 August 2003
Accommodation/Occupational Safety › Potable Water System
Issued 29 July 2003 Resolved
Tighten/renew potable water pump packing to stop excessive leaking. LEGACY COMPONENT DESC: Pump
Action required: 705 - Other - as specified
Due 20 August 2003
Resolved 30 August 2003
Resolution: Received email report from [name withheld] (OIM) stating that new pump was installed this date.
Fire Fighting › Fire Main › Condition
Issued 29 July 2003 Resolved
Renew leaking gasket in flanged connection IWO salt water jumper valve - fire main.
Action required: 705 - Other - as specified
Due 20 August 2003
Resolved 7 August 2003
Electrical › Electric Supply System (service) › Battery Installation Ventilation
Issued 29 July 2003 Resolved
Prove proper operation of exhaust vent damper in MCC Battery Room.
Action required: 705 - Other - as specified
Due 20 August 2003
Resolved 7 August 2003
Engineering › Gas Turbine (auxiliary)
Issued 29 July 2003 Resolved
Secure excessive lube oil leak inside 513 turbine enclosure. Remove oil from deck.
Action required: 705 - Other - as specified
Due 20 August 2003
Resolved 1 August 2003
Fire Fighting › Fire Pumps › Arrangement
Issued 29 July 2003 Resolved
Replace exhasut lagging for exposed piping for PBE-351 fire pump.
Action required: 705 - Other - as specified
Due 20 August 2003
Resolved 15 September 2003
Engineering › Freshwater System (intermediary cooling)
Issued 29 July 2003 Resolved
Permanently mount cooling water filter (currently held in place via slings/come-alongs) & hard-pipe where possible. LEGACY COMPONENT DESC: Filter
Action required: 705 - Other - as specified
Due 20 August 2003
Resolved 24 August 2003
Resolution: Received email report from [name withheld] that filter was hard pipied into the system this date.
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 29 July 2003 Resolved
Repair CO2 cabinet door for turbine ZAN-513 enclosure.
Action required: 705 - Other - as specified
Due 20 August 2003
Resolved 30 July 2003
Lifesaving › Rescue Boat › Markings
Issued 29 July 2003 Resolved
Renew all retroreflective tape on rescue boat & where needed on lifeboats.
Action required: 705 - Other - as specified
Due 20 August 2003
Resolved 3 August 2003
Lifesaving › Lifeboat › Lamp (inside)
Issued 29 July 2003 Resolved
Renew cracked glass light cover for lifeboat #2 interior light.
Action required: 705 - Other - as specified
Due 20 August 2003
Resolved 1 August 2003
Lifesaving › Launching Appliances › Falls
Issued 29 July 2003 Resolved
Renew lifeboat falls on (or before) 27OCT03.
Action required: 705 - Other - as specified
Due 27 October 2003
Resolved 15 September 2003
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 29 July 2003 Resolved
Provide CO2 operating instructions for ZAN-512 turbine and all air compressors.
Action required: 705 - Other - as specified
Due 20 August 2003
Resolved 30 July 2003
Fire Fighting › Fixed Gas Fire Extinguishing System › Control Valve
Issued 29 July 2003 Resolved
Renew lanyard for hammer (break-glass type) for manual pull on MCC.
Action required: 705 - Other - as specified
Due 20 August 2003
Resolved 30 July 2003
Lifesaving › Launching Appliances › Release Mechanism
Issued 29 July 2003 Resolved
Provide evidence of lifeboat & rescue boat release gear test @ 1.1 B-weight IAW 46 CFR 109.301(i)(5). LEGACY COMPONENT DESC: Release Mechanism
Action required: 705 - Other - as specified
Due 7 August 2003
Resolved 15 September 2003
Resolution: Release gear had not been tested since manufacture. Tests scheduled with [name withheld] for 13SEP03.
Fire Fighting › Fire Main
Issued 15 January 2003 Resolved
Install adequate number of support brackets to support fire main branch piping & sewage piping for temporary accomodations modules.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 January 2003
Resolved 18 January 2003
Resolution: Received docmentation from [name withheld] - Hoover OIM - that brackets had been installed.
Fire Fighting › Structural Fire Protection - General
Issued 15 January 2003 Resolved
Install door closers on exterior doors of temporary accomodation modules. LEGACY COMPONENT DESC: Accommodation Space Protection
Action required: 705 - Other - as specified
Due 1 February 2003
Resolved 15 March 2003
Engineering › Generator (propulsion-electric)
Issued 11 July 2002 Resolved
Make necessary repairs to ensure gas-tight cable duct penetrations for 510 through 513 generators, & make necessary repairs to 510 & 513 generator turbine exhaust installations.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 August 2002
Resolved 13 August 2002
Resolution: Verified to be resolved via email w/ digital photos from George E. Sellers (OIM) on 13AUG02.
Construction/Loadline › Hull
Issued 11 July 2002 Resolved
Clean out & provide video coverage of southwest & northwest corners between decks #4, #6, & #9. Video must accurately show connections between riser guides and centerwell plating. ISIP requirement.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 October 2002
Resolved 18 November 2002
Resolution: Video provided with transmittal of report of hull ISE this date.
Deck/Cargo
Issued 31 May 2001 Resolved
PROVIDE DOCUMENTATION THAT CRANES #1 & #2 HAVE COMPLETED ABS ANNUAL EXAMINATION.
Condition: Unknown
Due 30 January 2002
Resolved 30 January 2002
Deck/Cargo
Issued 31 May 2001 Resolved
Repair cat-walks on both cranes for safety of personnel servicing cranes.
Condition: Unknown
Due 30 January 2002
Resolved 30 January 2002
Engineering
Issued 31 May 2001 Resolved
PROVIDE PROPER AIR RELIEF VALVES FOR AIR RECIEVERS LOCATED BEHING GENERATORBLDG. LOCATED ON ENSCO 26 DRILLING UNIT PACKAGE. ONCE PROPER RELIEF VALVES ARE ON-BOARD, POP-TEST ALL SIX RELIEF VALVES ON CONTROL AIR SYSTEM.
Condition: Unknown
Due 31 January 2002
Resolved 30 January 2002
Electrical
Issued 31 May 2001 Resolved
Locate and remove 480 volts to ground on main distribution board, located on Ensco 26 drilling unit.
Condition: Unknown
Due 30 January 2002
Resolved 30 January 2002
Electrical
Issued 31 May 2001 Resolved
Repair internal communications through-out platform (i.e. Akusta system) for 100% operations.
Condition: Unknown
Due 30 January 2002
Resolved 30 January 2002

Casualty record · 4

17 May 2004Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 3 injured · activity 2087860
19 December 2005Routine · role: Involved in a Marine Casualty · activity 2553771
29 December 2006Routine · role: Involved in a Marine Casualty · activity 2856548
24 September 2009Routine · role: Subject to Marine Inspection · activity 3607106
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

EXXONMOBIL HOOVER (2004–2009). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.