MAURY USCG vessel records
← All vessels

HOOVER DIANA

HOOVER DIANA is a 1999 industrial vessel. The Coast Guard has recorded 22 inspections since 2016, most recently in June 2025, along with 9 deficiencies.

Records from 2016 to 2025. Most recent: inspection, 16 June 2025.

Built
1999
Last inspected
16 June 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 2016.

Inspection record

Last inspected 16 June 2025
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 9 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WQZ430
467291
Flag
UNITED STATES
Maury page id
psix-467291

Documentation record

Tonnage as PSIX records it34434 - Regulatory (Subpart C or D), Gross Ton
32746 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page

22 inspections, each with its date, unit and type; 9 deficiencies with the resolution recorded against each; the documentation record, as PSIX holds it. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 22

16 June 2025 Administrative Inspection
Administrative · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 8177969
14 October 2024 Administrative Inspection
Administrative · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 8021085
27 September 2023 Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7799692
2 August 2022 Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7527865
7 July 2022 Administrative Inspection
Administrative · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7499695
6 May 2021 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7193333
6 May 2021 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7193369
19 April 2021 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7178397
21 December 2020 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7114756
3 October 2019 Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6827820
8 August 2019 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6777126
8 July 2019 Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6759470
5 September 2017 Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6265003
15 August 2017 Type not recorded
No type recorded · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 6270012
21 February 2017 Type not recorded
No type recorded · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 6090300
15 February 2017 In-Service Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6109714
24 May 2016 Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5885878
10 May 2016 Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5899929
28 April 2016 Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5864621
28 April 2016 Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5864630
25 April 2016 Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5892867
12 February 2016 Deficiency Check · In-Service Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5814474

Deficiency record · 9

09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 May 2021 Resolved
In order to maintain system integrity, each individual electrical installation in a hazardous location must complyspecifically with incorporated references. Found 1 explosion proof light with a cracked housing exposing wires in a haz location.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 May 2021
Resolved 7 May 2021
Resolution: Replaced light with new light.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 October 2019 Resolved
THE EMERGENCY EQUIPMENT PROVIDED SHALL BE MAINTAINED IN GOOD CONDITION AT ALL TIMES. THE EDG ENCLOSURE HAS SERVERAL WASTED AREAS THAT WILL PREVENT PROPER USAGE OF FIXED CO2 SYSTEM.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2019
Resolved 26 October 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 October 2019 Resolved
THE EMERGENCY EQUIPMENT PROVIDED SHALL BE MAINTAINED IN GOOD CONDITION AT ALL TIMES. TWO OF THE EDG SRING ACTUATED LOUVERS WERE BROKEN.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2019
Resolved 26 October 2019
Electrical › Electrical Distribution System (service) › Wiring
Issued 16 February 2017 Resolved
Multiple electrical cables on the cellar desk were missing cable supports and needed to be properly secured.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 March 2017
Resolved 24 February 2017
Resolution: Vessel's crew installed wire supports and provided pictures to the Coast Guard.
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 25 May 2016 Resolved
The pin on the shackle holding the straps and hydrostatic release to the frame had backed out.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 May 2016
Resolved 25 May 2016
Resolution: Vessel's crew tightened pin and wire tied it into place.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 25 May 2016 Resolved
Exterior door from galley has a broken and disconnected closure device and the door does not latch.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 June 2016
Resolved 1 June 2016
Resolution: Rig's crew installed new closure device and latch and emailed pictures to the Coast Guard of repairs.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 25 May 2016 Resolved
Mulitiple emergency lights about the rig had burnt out bulbs.
Condition: Improper/Lack of Maintenance
Due 1 June 2016
Resolved 1 June 2016
Resolution: Rig's crew replaced burnt out light bulbs and provided pictures to the Coast Guard of new bulbs energized and burning brightly.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 25 May 2016 Resolved
Multiple lifejacket boxes had faded and unreadable lables. Multiple liferings did not have proper placards at their location.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 June 2016
Resolved 1 June 2016
Resolution: Rig's crew installed proper lables and placards and provided pictures to Coast Guard.
Electrical › Electrical Distribution System (service) › Switch
Issued 25 May 2016 Resolved
A switchbox on the south production deck has rusted off its mount and is free hanging by the cable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 June 2016
Resolved 1 June 2016
Resolution: Rig's crew remounted the switchbox and provided pictures to the Coast Guard.