MAURY USCG vessel records Sign in
← All vessels

AURORA D

AURORA D is a 1997 public freight. The Coast Guard has recorded 34 inspections since 1997, most recently in April 2017, along with 11 deficiencies and 3 operational controls.

Records from 1997 to 2017. Most recent: inspection, 27 April 2017.

Built
1997
Last inspected
27 April 2017
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9149732 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
467335
Flag
ITALY
—
Maury page id
psix-467335

Inspections, by type

…with no type recorded10
Years with a record 16 calendar years (1997–2017)
The 34 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it15355 - Convention (Subpart B), Gross Ton
7706 - Convention (Subpart B), Net Ton
29846 - Displacement, Metric Ton
23923 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 34

27 April 2017 NPV Safety Exam · Ballast Water Examination · ISPS III Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6133551
22 April 2017 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6130119
4 January 2017 COE-Dockside
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6064974
16 May 2016 ISPS II Exam · Ballast Water Examination · Deficiency Check · PII Safety Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5870416
10 September 2015 PII Safety Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5719644
9 September 2015 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5717168
7 August 2015 Ballast Water Examination · ISPS III Exam · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5202212
8 July 2009 MARPOL Annex I Examination · MARPOL Annex VI Survey · Ballast Water Examination · ISPS II Exam · PII Safety Exam · MARPOL Annex V Examination
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3527970
25 March 2009 Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3439881
12 February 2009 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3417096
14 July 2008 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3260024
1 April 2008 Administrative Inspection
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3175717
11 February 2008 Administrative Inspection
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3145644
1 July 2007 Administrative Inspection
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2979309
28 April 2007 Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2917535
26 January 2007 Administrative Inspection
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2862266
19 September 2006 MARPOL Annex I Examination · PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2782352
12 August 2005 Ballast Water Examination · MARPOL Annex I Examination · Random ISPS/MTSA/PSC
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2457445
26 November 2004 NPV Safety Exam
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2250736
22 November 2004 NPV Safety Exam · Ballast Water Examination · ISPS III Exam
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2245890
27 April 2004 Annual Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2048835
27 April 2004 MTSA/ISPS Verification
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2054180
15 November 2003 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1943990
15 April 2003 Annual Inspection
Physical examination · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 1774920
19 September 2002 Re-Inspection · Ballast Water Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1673865
12 September 2002 Type not recorded
No type recorded · Sector Astoria · USCG Northwest District (CGD-NW) · Activity 1676273
15 February 2002 Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1485809
7 August 2001 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 292511
31 January 2001 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 286525
18 February 2000 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 275028
18 February 2000 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 276079
9 February 1999 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 425248
1 June 1998 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 417304
24 November 1997 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 410121

Deficiency record · 11

Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 10 September 2015 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. The #5 cylinder is leaking jacket water. The vessel's crew has rigged a rubber hose down two decks in the engine room to drain into a drum.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 10 September 2015
Resolved 14 September 2015
Resolution: RINA survey received stating the deficiency has been cleared.
Engineering › Feedwater/Condensate Water System › Tank
Issued 10 September 2015 Resolved
Boilers shall be provided with means to supervise and control the quality of the feed water. Suitable arrangements shall be provided to preclude as far as practicable, the entry of oil or other contaminants which may adversley affect the boiler. Discovered a rubber tube that carried condensation water from the a/c unit to the boiler feed water tank. The hatch of the tanks was left open with water
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 September 2015
Resolved 10 September 2015
Resolution: The modification was removed while team was still on board.
Fire Fighting › Fixed Fire Detection System › Alarms
Issued 7 August 2015 Resolved
0750 - Fire Prevention - Fire protection systems and fire-fighting systems shall be maintained ready for use. PSCO observed fire detection panel on bridge disabled rendering any detectors in the purifier space inoperative. - SOLAS 74 (am) Ch II-2/14
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 August 2015
Resolution: Received class report from RINA stating that the outstanding deficiency has been rectified.
Fire Fighting › Fixed Fire Detection System › Control Valve
Issued 7 August 2015 Resolved
0715 - Fire Detection - The administration may permit the use of oil-level gauges with flat glasses and self closing. PSCO observed a gagging device on the normally closed valve, located on the cylinder oil tank gauge. Depicted next to the sight glass is a "No Gagging" diagram. - SOLAS 74 (am) II-2/7
Condition: Placed in Improper Service
Due 21 August 2015
Resolved 16 May 2016
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 7 August 2015 Resolved
0910 - Closing devices watertight doors - Doors fitted in category A boundaries shall be reasonably gastight and self-closing. Door leading into steering gear space does not fully close. - SOLAS 74 (am) Ch. II-2/9
Condition: Improper/Lack of Maintenance
Due 21 August 2015
Resolved 16 May 2016
Operations/Management › Pollution › Control of Garbage
Issued 7 August 2015 Resolved
2120- Garbage- every ship shall provide a garbage management plan that provides proper stowage of garbage- PSCO observed significant amounts of garbage stowed in the crane house.- MARPOL Annex V/10
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 August 2015
Resolved 12 August 2015
Resolution: Received excerpt from GM plan allowing for extended stowage of garbage in areas designated by Capt.
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 7 August 2015 Resolved
1721- retention of oil; on board- a ship of 300 GT must have an enclosed area around every overflow and fill pipe and have a capacity of at least 1.5 barrels- vessel's enclosed areas do not have plugging arrangements at bottom of containments to prevent spills from escaping containment to prevent spills from escaping containment- 33CFR155.320
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 August 2015
Resolved 16 May 2016
Lifesaving › Lifeboat › Propulsion Starting System
Issued 7 August 2015 Resolved
0610- lifeboats- before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order- PSCO observed several unsuccessful attempts to start the lifeboat motor by the engineers- SOLAS 74 (am) CH. III/20
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 August 2015
Resolution: Received class report from RINA stating that the outstanding deficiency has been rectified.
Navigation › Collision/Grounding Avoidance › Radar
Issued 12 February 2009 Resolved
1530 - Radar - Prior to departure, notification was received from vessel of inoperable 10cm radar. Outbound LOD was issued. Certified repair is needed to return radar to normal operating specifications.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 13 February 2009
Resolved 3 March 2009
Resolution: Repair was made in Japan by Furuno Electric Co., LTD.
Navigation › Piloting/Steering › Marine Charts
Issued 22 November 2004 Resolved
Vessel does not have chart 18650 corrected up to date. This chart is needed to transit to Stockton, Ca.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 November 2004
Resolved 26 November 2004
Resolution: Vessel was boarded and deficiency was rectified. 18650 was corrected up to date.
Lifesaving › Launching Appliances
Issued 15 February 2002 Resolved
STARBOARD AFT PAD FOR LIFEBOAT DAVIT LOOSE AND TORN. LEGACY COMPONENT DESC: PAD FOR LIFEBOAT DAVIT
Condition: Damaged By Earlier Event
Action required: 15 - Rectify deficiencies by next port
Due 16 February 2002
Resolved 16 February 2002
Resolution: PAD REPAIRED AND PICTURES FAXED TO MSO.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.