← All vessels
AURORA D
AURORA D is a 1997 public freight. The Coast Guard has recorded 34 inspections since 1997, most recently in April 2017, along with 11 deficiencies and 3 operational controls.
Records from 1997 to 2017. Most recent: inspection, 27 April 2017.
- Built
- 1997
- Last inspected
- 27 April 2017
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 11 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9149732 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
ICDO
467335
Flag
ITALY
—
Maury page id
psix-467335
Inspections, by type
…with no type recorded10
Years with a record
16 calendar years (1997–2017)
The 34 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it15355 - Convention (Subpart B), Gross Ton
7706 - Convention (Subpart B), Net Ton
29846 - Displacement, Metric Ton
23923 - Dead Weight, Metric Ton
7706 - Convention (Subpart B), Net Ton
29846 - Displacement, Metric Ton
23923 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 34
27 April 2017
NPV Safety Exam · Ballast Water Examination · ISPS III Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6133551
22 April 2017
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6130119
4 January 2017
COE-Dockside
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6064974
16 May 2016
ISPS II Exam · Ballast Water Examination · Deficiency Check · PII Safety Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5870416
10 September 2015
PII Safety Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5719644
9 September 2015
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5717168
7 August 2015
Ballast Water Examination · ISPS III Exam · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5202212
8 July 2009
MARPOL Annex I Examination · MARPOL Annex VI Survey · Ballast Water Examination · ISPS II Exam · PII Safety Exam · MARPOL Annex V Examination
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3527970
25 March 2009
Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3439881
12 February 2009
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3417096
14 July 2008
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3260024
1 April 2008
Administrative Inspection
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3175717
11 February 2008
Administrative Inspection
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3145644
1 July 2007
Administrative Inspection
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2979309
28 April 2007
Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2917535
26 January 2007
Administrative Inspection
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2862266
19 September 2006
MARPOL Annex I Examination · PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2782352
12 August 2005
Ballast Water Examination · MARPOL Annex I Examination · Random ISPS/MTSA/PSC
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2457445
26 November 2004
NPV Safety Exam
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2250736
22 November 2004
NPV Safety Exam · Ballast Water Examination · ISPS III Exam
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2245890
27 April 2004
Annual Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2048835
27 April 2004
MTSA/ISPS Verification
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2054180
15 November 2003
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1943990
15 April 2003
Annual Inspection
Physical examination · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 1774920
19 September 2002
Re-Inspection · Ballast Water Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1673865
12 September 2002
Type not recorded
No type recorded · Sector Astoria · USCG Northwest District (CGD-NW) · Activity 1676273
15 February 2002
Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1485809
7 August 2001
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 292511
31 January 2001
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 286525
18 February 2000
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 275028
18 February 2000
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 276079
9 February 1999
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 425248
1 June 1998
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 417304
24 November 1997
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 410121
Deficiency record · 11
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 10 September 2015
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. The #5 cylinder is leaking jacket water. The vessel's crew has rigged a rubber hose down two decks in the engine room to drain into a drum.
Engineering › Feedwater/Condensate Water System › Tank
Issued 10 September 2015
Resolved
Boilers shall be provided with means to supervise and control the quality of the feed water. Suitable arrangements shall be provided to preclude as far as practicable, the entry of oil or other contaminants which may adversley affect the boiler. Discovered a rubber tube that carried condensation water from the a/c unit to the boiler feed water tank. The hatch of the tanks was left open with water
Fire Fighting › Fixed Fire Detection System › Alarms
Issued 7 August 2015
Resolved
0750 - Fire Prevention - Fire protection systems and fire-fighting systems shall be maintained ready for use. PSCO observed fire detection panel on bridge disabled rendering any detectors in the purifier space inoperative. - SOLAS 74 (am) Ch II-2/14
Fire Fighting › Fixed Fire Detection System › Control Valve
Issued 7 August 2015
Resolved
0715 - Fire Detection - The administration may permit the use of oil-level gauges with flat glasses and self closing. PSCO observed a gagging device on the normally closed valve, located on the cylinder oil tank gauge. Depicted next to the sight glass is a "No Gagging" diagram. - SOLAS 74 (am) II-2/7
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 7 August 2015
Resolved
0910 - Closing devices watertight doors - Doors fitted in category A boundaries shall be reasonably gastight and self-closing. Door leading into steering gear space does not fully close. - SOLAS 74 (am) Ch. II-2/9
Operations/Management › Pollution › Control of Garbage
Issued 7 August 2015
Resolved
2120- Garbage- every ship shall provide a garbage management plan that provides proper stowage of garbage- PSCO observed significant amounts of garbage stowed in the crane house.- MARPOL Annex V/10
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 7 August 2015
Resolved
1721- retention of oil; on board- a ship of 300 GT must have an enclosed area around every overflow and fill pipe and have a capacity of at least 1.5 barrels- vessel's enclosed areas do not have plugging arrangements at bottom of containments to prevent spills from escaping containment to prevent spills from escaping containment- 33CFR155.320
Lifesaving › Lifeboat › Propulsion Starting System
Issued 7 August 2015
Resolved
0610- lifeboats- before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order- PSCO observed several unsuccessful attempts to start the lifeboat motor by the engineers- SOLAS 74 (am) CH. III/20
Navigation › Collision/Grounding Avoidance › Radar
Issued 12 February 2009
Resolved
1530 - Radar - Prior to departure, notification was received from vessel of inoperable 10cm radar. Outbound LOD was issued. Certified repair is needed to return radar to normal operating specifications.
Navigation › Piloting/Steering › Marine Charts
Issued 22 November 2004
Resolved
Vessel does not have chart 18650 corrected up to date. This chart is needed to transit to Stockton, Ca.
Lifesaving › Launching Appliances
Issued 15 February 2002
Resolved
STARBOARD AFT PAD FOR LIFEBOAT DAVIT LOOSE AND TORN. LEGACY COMPONENT DESC: PAD FOR LIFEBOAT DAVIT
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National