SPIRIT OF HUDSON

SPIRIT OF HUDSON is a 1970 passenger vessel (inspected). The Coast Guard has recorded 13 inspections since 2016, most recently in September 2023, along with 40 deficiencies, 4 operational controls, 1 with no removal date recorded and 2 casualty investigations between 2004 and 2021.

Records from 2004 to 2023. Most recent: inspection, 25 September 2023.

Built
1970
Last inspected
25 September 2023
Documentation
Expired · documentation file of 10 August 2026
Controls
1 with no removal date recorded

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 25 September 2023
…with no type recorded1
Operational controls 1 with no removal date recorded
Years with a record 8 calendar years (2016–2023)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDB4729
Flag
UNITED STATES
Maury page id
psix-46738

Documentation record

Registered dimensions (L × B × D)57.0 ft × 17.0 ft × 5.3 ft
Registered tonnagegross 44 / net 31
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMILLER'S MARINE RAILWAY · DELTAVILLE VA, UNITED STATES · built 1970
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portHUDSON, NY
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it44 - Regulatory (Subpart C or D), Gross Ton
31 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 13

25 September 2023 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7797677
18 August 2022 Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7535970
20 June 2021 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7231014
20 June 2021 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7231901
10 June 2021 Deficiency Check · COI Inspection · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7212507
28 January 2021 Plan Review "T" Boat · Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7133697
6 November 2020 Plan Review "T" Boat · Administrative Inspection · Construction Oversight
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7090698
13 July 2020 Examination of Repairs · Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7004972
29 May 2019 Deficiency Check · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6698746
29 October 2018 Plan Review "T" Boat
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6570075
14 June 2018 Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6443821
20 June 2017 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6181076
20 June 2016 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5915189

Deficiency record · 40

07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 18 August 2022 Resolved
On a ferry vessel of not more than 19.8 meters (65 feet) in length carrying not more than 49 passengers, the minimum capacity of the fire pump must be 10 gallons per minute. Vessel was unable to maintain capacity of 10 gallons per minute.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 August 2022
Resolution: Vessel Operator was able to perform a satisfactory test of vessel's fire pump. Vessel operator sent video of fire pump test after inspection. Found issue was due to a clogged valve.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 18 August 2022 Resolved
The person in command of a documented vessel must have on board that vessel the original Certificate of Documentation current in effect for that vessel. MI discovered that the vessel's Certificate of Documentation has expired.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 September 2022
Resolved 19 August 2022
Resolution: Received photograph from operator of valid/current COD.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 August 2022 Resolved
Nonconductive deck material, mats, or gratings must be provided in front of each switchboard/panel. MI discovered that the switchboard/distrubution panel in the galley space did not have nonconductive deck material.
Action required: 10 - Deficiency Rectified
Resolved 18 August 2022
Resolution: Corrected the on the spot. Placed non-conducting mating in galley space.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 August 2022 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. MI discovered a hydraulic leak on the port hyrdaulic line.
Action required: 10 - Deficiency Rectified
Resolved 18 August 2022
Resolution: Operator cleaned hydraulic line/tightened up loose fittings. Conducted steering test and did not see any further leak. Corrected on the spot.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 June 2021 Resolved
A shutoff valve, installed so as to close against the fuel flow, shall be fitted in the fuel supply line to stop the fuel flow at the tank connection. Port side diesel fuel tank was leaking fuel at the emergency fuel shut off valve on the forward side of the tank. Vessel owner/operator stated that the fuel tank will be isolated from being used until fuel can be safely transferred out of the tank to conduct repairs. 46 CFR “OLD T” 182.20-35 (b)(3)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 June 2021
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 10 June 2021 Resolved
- Each vessel required to have a Certificate of Inspection is subject to the annual vessel inspection fee listed in table 46 CFR 2.10-101. User fees for 2021 have not been paid. 46 CFR 2.10-101 (a)(1)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 June 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 10 June 2021 Resolved
Bilge alarm for the tank room was not labeled at the operating station. 46 CFR “OLD T” 183.01-15(a)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 June 2021
09 - Working and Living Conditions › 092 - Working Conditions › Structural features (ship)
Issued 10 June 2021 Resolved
On passengers decks of vessels engaged in excursion type operation, the spaces below the rail shall be fitted with chain link fencing, wire mesh or the equivalent. Chain link fencing along the bottom under top railing at the bow is missing. 46 CFR “OLD T” 177.35-1(c)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 June 2021
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 10 June 2021 Resolved
For fire extinguishing systems or equipment that are not required but are installed, the system or equipment and its installation shall meet requirements of this part. Three additional fire extinguishers located at the bow and two in the snack bar space are not equipped with marine grade brackets. 46 CFR “OLD T” 181.05-5(a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 June 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 10 June 2021 Resolved
High level alarm in the engine room is inoperable. 46 CFR “OLD T” 183.01-15(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 June 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 10 June 2021 Resolved
Remote fuel shutoff stations shall be marked in at least 1 inch letters indicating purpose of the valve and direction of operation. Emergency fuel shut off for the generator was not labeled. 46 CFR “OLD T” 185.30-20
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 June 2021
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 10 June 2021 Resolved
Ground fault detector lights were not operational. 46 CFR “OLD T” 183.01-15(a)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 June 2021
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 June 2021 Resolved
Several items were identified as being electrical hazards and were removed from the vessel. This included two space heaters, a shop vacuum and large extension cord with broken or missing grounding prongs. 46 CFR “OLD T” 183.01-15(a)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 10 June 2021
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 28 January 2021 Resolved
After installation of the fuel tank on a vessel, the complete installation must be tested in the presence of a marine inspector, or individual specified by the cognizant OCMI, to a heat not less than that to which the tank may be subjected in service. Fuel may be used as the testing medium. Vessel installed a new fuel tank on the port side. 46 CFR 182.440(c)(2)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 June 2021
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 13 July 2020 Resolved
Vessel was observed hauled out at Scarano's Shipyard in Albany, NY with an approximately 6" x 18" hole in the bottom plating in the vicinity of the keel. Prior to vessel movement, complete satisfactory credit drydock and internal structure exams.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 30 November 2020
Resolution: Final weld NDT SAT.
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 29 May 2019 Resolved
Wipe entire deck and stow appropriately or remove all gear adrift in engine room.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2019
Resolved 5 June 2019
Resolution: Deck wiped and gear stowed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 May 2019 Resolved
Remove and replace all exhaust lagging in engine room. Action changed to 701C on 6/5/2019 due to not being completed ny the original due date. - MHM
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 June 2019
Resolved 12 June 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 May 2019 Resolved
Remove all dead end wires in engine room.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2019
Resolved 5 June 2019
Resolution: MI saw no dead end wires in the E/R.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 29 May 2019 Resolved
Label and stow appropraitely all lifejackets.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2019
Resolved 5 June 2019
Resolution: Lifejackets labeled and stowed.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 29 May 2019 Resolved
Conduct satisfactory fire drill in the presence of a Coast Guard Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 June 2019
Resolution: MI's witnessed satisfactory fire drill.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 29 May 2019 Resolved
Conduct satisfactory mob drill in the presence of a Coast Guard Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 June 2019
Resolution: MI's witnessed satisfactory MOB drill.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 29 May 2019 Resolved
Bilge high level alarm in lazarette compartment broken and electrical connection must be made in an enclosure/junction box. Cable piercing bulkhead must be made through a metallic fitting. Action reiterated as 701C due to being incomplete. Crew had placed the connection in a junction box, then mounted it to the ladder with zip straps; bulkhead piercing was still not in a metallic fitting. - MHM
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 June 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 May 2019 Resolved
Breaker panel in aft bar area must be labeled (markings worn). Remove dead end wires in vicinity of panel. Remove all extension cords in bar are and throughout vessel; only hard wire electrical cable runs authorized.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2019
Resolved 5 June 2019
Resolution: Dead end wires removed, extension cords removed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 29 May 2019 Resolved
Replace first aid kit in aft bar area.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2019
Resolved 5 June 2019
Resolution: first aid kit replaced.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 29 May 2019 Resolved
Remove "party" string lights from exterior of vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 June 2019
Resolution: Lights removed.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 29 May 2019 Resolved
Maintain lifesaving inspection record in ship's log.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 June 2019
Resolution: Master notates LS insp. in the log now.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 29 May 2019 Resolved
Update crew list and provide evidence of enrollment in drug program. Updated to due date of 30JUN2019 to align with DAPI expiration. - MHM
Action required: 705 - Other - as specified
Due 30 June 2019
Resolved 12 June 2019
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 29 May 2019 Resolved
Pay user fee.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 June 2019
Resolution: Receipt for user fee shown to MI.
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 14 June 2018 Resolved
DC01: Stbd side fuel tank has an unauthorized repair/patch on the bottom of tank. Vessel is to submit a repair proposal to OCMI for approval to affect permanent repairs. Fuel tank has been taken out of service.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 July 2018
Resolved 30 November 2018
Resolution: New fuel tank installed IAW 46 CFR 182.440
Engineering › Fuel Oil Service System › Valve, Control
Issued 14 June 2018 Resolved
DC02: Fuel tank shutoff valves must be provided for both fuel tanks and must be located outside the tank space. The shutoff valves located on the main deck have been taken out of service. Vessel is to make arrangements to put shutoff valves back in service.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 July 2018
Resolved 16 September 2018
Resolution: Vessel made arrangements for shutoff valves to be accessed from outside the space.
Navigation › Piloting/Steering › US Coast Pilot
Issued 14 June 2018 Resolved
DC03: Vessel must carry up-to-date publications. Vessel did not have current light list and coast pilot on board.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 July 2018
Resolved 16 September 2018
Resolution: vessel provided current light list and coast pilot.
Communications › Radio Communications › VHF Radiotelephone
Issued 20 June 2017 Resolved
Install a VHF radio with digital selective calling (DSC) capability.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 21 July 2017
Resolved 28 September 2017
Resolution: Recieved photo from operator with new VHF radio installed.
Engineering › Pressure Vessel › Marking and Stamping
Issued 20 June 2017 Resolved
Pressure vessels that have an internal volume less than 5 cubic feet must be stamped with AMSE "U" or "UM". Provide paperwork to prove existing air compressor complies with ASME or replace.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 21 July 2017
Resolved 28 September 2017
Resolution: Recieved photo from operator with new ASME approved air compressor installed.
Engineering › Bilge Water Management System › Not Installed
Issued 20 June 2016 Resolved
Install bilge alarm in #2 void where transducer is installed. A visual and audible alarm must be provided at operating station in a space with a through hull fitting below the waterline.
Condition: Invalid
Action required: 705 - Other - as specified
Due 20 July 2016
Resolved 18 November 2016
Resolution: The owner sent pictures via email of an installed bilge alarm.
Electrical › Electrical Distribution System (emergency) › Ground Detection
Issued 20 June 2016 Resolved
Provide proper operation of ground detection on electric panel in galley.
Condition: Invalid
Action required: 705 - Other - as specified
Due 20 July 2016
Resolved 18 November 2016
Resolution: The owner corrected the lights on the ground detection panel in the galley.
Engineering › Diesel Engine (auxiliary) › Valve
Issued 20 June 2016 Resolved
Repair coolant leak on port MDE.
Condition: Invalid
Action required: 705 - Other - as specified
Due 20 July 2016
Resolved 18 November 2016
Resolution: Coolant leak on port MDE was corrected.
Engineering › Fuel Oil Service System › Valve
Issued 20 June 2016 Resolved
Repair hydrolic leak on STBD side. Hydrolic oil is leaking on exposed electrical wims.
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 June 2016
Resolved 18 November 2016
Resolution: Hydrolic leak on STBD of electrical wims has been corrected. Owner sent pictures via email.
Engineering › Sea-water System (primary cooling) › Pump
Issued 20 June 2016 Resolved
Repair leak on generator seawater intake in engine room. Replace hose and double clamp.
Condition: Invalid
Action required: 705 - Other - as specified
Due 20 July 2016
Resolved 18 November 2016
Resolution: Owner sent pictures of replaced double hose clamp for the generator leak on the seawater intake.
Construction/Loadline › Structures › End Bulkhead
Issued 20 June 2016 Resolved
Remove paint and inspect collision bulkhead and surrounding frames at next DD/ISE or next haul out.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 30 September 2020
Engineering › Diesel Engine (auxiliary) › Valve
Issued 20 June 2016 Resolved
Provide proper operation of STBD RPM gauge.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 18 November 2016
Resolution: Provided proper operation

Casualty record · 2

3 May 2004Significant Marine Casualty · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 2073812
20 June 2021Routine · role: Involved in a Marine Casualty · activity 7231901
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.