This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Registered dimensions (L × B × D)61.6 ft × 17.2 ft × 8.9 ft
Registered tonnagegross 57 / net 38
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderHALTER MARINE SVCS INC · NEW ORLEANS, LA, UNITED STATES · built 1970
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSAN FRANCISCO, CA
Endorsements, as the file codes themcw_un, reg
DocumentationNo Operation - PM · issued 30 June 2004
Service, as the file records itPassenger (Uninspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it57 - Regulatory (Subpart C or D), Gross Ton 38 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel
Behind this panel: 10 inspections, each with its date, unit and type; 15 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1972 to
2026, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 10
5 November 2020Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7090444
14 October 2020Drydock Exam · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7076641
26 June 2020Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6986975
19 August 2019Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6788109
1 October 2018Administrative Inspection
Administrative · Navigation Center · Activity 6552168
20 September 2018Administrative Inspection · Deficiency Check · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6544692
23 August 2018Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6520649
6 September 2017Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6261305
A hatch exposed to the weather must be watertight. A hatch cover must have securing devices and be attached to th hatch frame to prevent its loss. The watertight hatch leading into the accommodation space from the aft deck has a loose upper dog and does not fully seal. It does not meet its intended purpose of being watertight. Repair the dog on the door so that the hatch is watertight.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 July 2020
Resolved 29 June 2020
Resolution: Vessel provided photo of in/outside of hatch with dog properly adjusted.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 26 June 2020Resolved
A vessel must carry one floating waterlight, unless it is limited to daytime operation. The battery for light on the life ring was found to be past its expiration date. The battery was replaced with a valid battery on scene by the operator.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 26 June 2020
Resolved 26 June 2020
Resolution: Battery was replaced with a vailid spare battery on scene by the operator.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 26 June 2020Resolved
At each initial and subsequent inspection the own shall be prepared to conduct tests and have the equipment ready for inspection, including the following: Inspection of each hysrostatic release unit to determine that it is in compliance with servicing and usage requirements of 185.740 of this chapter. The EPIRB was found to have an expired hydrostatic release installed. This was replaced on scene with a valid hydrostatic release by the vessel operator.
Action required: 10 - Deficiency Rectified
Due 26 June 2020
Resolved 26 June 2020
Resolution: Operatir replaced the hydrostatic release with an approved replacement in the presence of the marine inspectors on scene.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 19 August 2019Resolved
At all inspections special attention shall be paid to ensure that no fire hazards exist and that guards or protective devices are provided in all hazardous places. Vessel does not have a means to close supply vents to engine room in the event of a fire.
46 CFR 176.25-10
Condition: Design Flaw
Action required: 705 - Other - as specified
Resolved 3 September 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 19 August 2019Resolved
At each initial and subsequent inspection for certification, the marine inspector shall view the vessel afloat and shall conduct the following tests and inspections of the hull structure and its appurtenances: Examine and test by operation all watertight closures in the hull, decks and bulkheads. Marine Inspectors observed water accumulation in the fore-peak. Perform maintenance on the watertight hatch. Prove proper operation to a Marine Inspector.
46 CFR 176.25-5
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 September 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 19 August 2019Resolved
At each initial and subsequent inspection for certification, the marine inspector shall view the vessel afloat and shall conduct the following tests and inspections of the hull structure and its appurtenances:
Examine all wheatertight closures above deck. Marine Inspector observed a small hole in the vicinity of the operating station. Fix the hole. Prove intergrity.
46 CFR 176.25-5
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 September 2019
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 August 2019Resolved
Employers must maintain records of chemical tests as provided in 49 CFR 40.333 and must make these records available to Coast Guard officials upon request.(b) The records shall be sufficient to: (1) Satisfy the requirements of §§ 16.210(b) and 16.220(c) of this part.
(2) Identify the total number of individuals chemically tested annually for dangerous drugs in each of the categories of testing required by this part including the annual number of individuals failing chemical tests and the number and types of drugs for which individuals tested positive. Documentation shall be available upon request. Provide documentation attesting to your drug and alcohol testing program.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 September 2019
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 1 October 2018Resolved
CLSN: Vsl is not broadcasting a Call Sign, ZERO DRAFT: no static draft information
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 26 June 2020
Resolution: Vessel rep confirmed via follow up email the AIS information has been corrected.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 September 2017
Resolved 15 September 2017
Resolution: Stern light bulb replaced; all sat.
Correctly labeled hydrostatic release expiration date on IBA
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 September 2017
Resolved 15 September 2017
Resolution: Correctly labeled hydrostatic release on IBA
Electrical › Electrical Distribution System (service) › Cable
Issued 15 September 2017Resolved
Properly secure cable chaffing on steering gear.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 September 2017
Resolved 15 September 2017
Resolution: Properly secured cable that was chaffing on steering gear
Engineering › Bilge Water Management System › Manifold
Issued 15 September 2017Resolved
Properly label bilge manifold.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 September 2017
Resolved 15 September 2017
Resolution: Properly labeled bilge manifold
Remove trash can sitting over emergency escape hatch
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 September 2017
Resolved 15 September 2017
Resolution: Removed trash can sitting over emergency escape hatch
Stability › Watertight Integrity › General
Issued 2 November 2016Resolved
Replace stbd shaft seal.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 November 2016
Resolution: New shaft seal installed and inspected.
Construction/Loadline › Penetrations › Weld
Issued 29 June 2016Resolved
Make forepeak hatch watertight, minor leak at the 7 o'clock position while looking forward. The deck has an area of very thin steel that will need to be replaced at the drydock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 July 2016
Resolved 2 November 2016
Resolution: Hatch gasket replaced, no metal work necessary.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.