← All vessels
HAWK
Passenger (Uninspected) · Passenger Ship class · Built 1970s · USCG Southwest District (CGD-SW) · Other hulls named HAWK
HAWK is a 1970 passenger vessel (uninspected). The Coast Guard has recorded 66 inspections since 1985, most recently in November 2020, along with 137 deficiencies and 1 operational control.
Records from 1985 to 2020. Most recent: inspection, 5 November 2020.
- Built
- 1970
- Last inspected
- 5 November 2020
- Documentation
- No Operation - PM · documentation file of 10 September 2026
- Deficiencies
- 137 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
529545
WCW8422
46746
Flag
UNITED STATES
367123640 (licence lapsed)
Maury page id
psix-46746
Inspections, by type
…with no type recorded9
Years with a record
34 calendar years (1985–2020)
The 66 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)61.6 ft × 17.2 ft × 8.9 ft
Registered tonnagegross 57 / net 38
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderHALTER MARINE SVCS INC · NEW ORLEANS, LA, UNITED STATES · built 1970
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSAN FRANCISCO, CA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationNo Operation - PM · issued 30 June 2004
Service, as the file records itPassenger (Uninspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it57 - Regulatory (Subpart C or D), Gross Ton
38 - Regulatory (Subpart C or D), Net Ton
38 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WCW8422MMSI 367123640 · cancelled · compulsorily equipped · granted 21 June 2016, cancelled 3 November 2020
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 66
5 November 2020
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7090444
14 October 2020
Drydock Exam · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7076641
26 June 2020
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6986975
19 August 2019
Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6788109
1 October 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6552168
20 September 2018
Administrative Inspection · Deficiency Check · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6544692
23 August 2018
Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6520649
6 September 2017
Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6261305
22 August 2016
Deficiency Check · Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5980843
29 June 2016
COI Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5922575
25 August 2015
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5226349
18 March 2014
Drydock Exam · Damage Survey · Examination of Repairs · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4871563
12 July 2012
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4376365
29 September 2010
Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3846406
23 March 2010
DAPI Audit · Deficiency Check
Physical examination · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 3701494
16 July 2009
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3536002
23 October 2008
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3341428
12 June 2007
Plan Review "T" Boat · Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2959825
5 July 2006
Deficiency Check · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2671341
12 July 2005
Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2374845
27 June 2005
Deficiency Check · Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2374835
6 August 2004
Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2158170
25 August 2003
Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1868646
7 July 2003
Plan Review "T" Boat · Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1809502
4 June 2002
Deficiency Check · Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1626150
22 February 2002
Administrative Inspection
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1488521
6 July 2001
Hull Examination · COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1403438
15 July 2000
Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1469679
17 August 1999
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1399170
22 June 1999
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1193590
23 June 1998
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 792495
29 April 1998
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1124834
30 September 1997
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1117868
8 August 1997
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1092320
10 March 1997
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 111976
25 February 1997
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1099755
13 September 1996
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 960507
6 September 1996
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1385794
6 July 1995
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1183154
10 February 1995
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1156438
15 July 1994
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1181901
1 April 1994
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1166778
9 February 1994
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 852474
31 August 1993
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 825661
22 June 1993
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 843743
20 July 1992
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 943161
19 June 1992
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 950004
22 January 1992
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 957157
15 November 1991
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1248945
10 December 1990
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1232498
8 November 1990
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1244156
29 October 1990
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 925085
2 July 1990
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 916021
15 June 1990
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1227592
12 April 1990
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1239635
1 February 1990
Deficiency Check · Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1240716
19 September 1989
Deficiency Check
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1193922
20 July 1989
Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1042498
20 July 1989
Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1207420
22 June 1989
COI Inspection · Hull Examination
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1193818
19 June 1989
Administrative
Administrative · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1345166
18 August 1988
Hull Examination · Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 893643
31 July 1987
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1337662
28 July 1987
Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1016274
30 July 1986
COI Inspection · Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1321880
10 July 1985
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1287400
Deficiency record · 137
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 26 June 2020
Resolved
A hatch exposed to the weather must be watertight. A hatch cover must have securing devices and be attached to th hatch frame to prevent its loss. The watertight hatch leading into the accommodation space from the aft deck has a loose upper dog and does not fully seal. It does not meet its intended purpose of being watertight. Repair the dog on the door so that the hatch is watertight.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 26 June 2020
Resolved
A vessel must carry one floating waterlight, unless it is limited to daytime operation. The battery for light on the life ring was found to be past its expiration date. The battery was replaced with a valid battery on scene by the operator.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 26 June 2020
Resolved
At each initial and subsequent inspection the own shall be prepared to conduct tests and have the equipment ready for inspection, including the following: Inspection of each hysrostatic release unit to determine that it is in compliance with servicing and usage requirements of 185.740 of this chapter. The EPIRB was found to have an expired hydrostatic release installed. This was replaced on scene with a valid hydrostatic release by the vessel operator.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 19 August 2019
Resolved
At all inspections special attention shall be paid to ensure that no fire hazards exist and that guards or protective devices are provided in all hazardous places. Vessel does not have a means to close supply vents to engine room in the event of a fire.
46 CFR 176.25-10
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 19 August 2019
Resolved
At each initial and subsequent inspection for certification, the marine inspector shall view the vessel afloat and shall conduct the following tests and inspections of the hull structure and its appurtenances: Examine and test by operation all watertight closures in the hull, decks and bulkheads. Marine Inspectors observed water accumulation in the fore-peak. Perform maintenance on the watertight hatch. Prove proper operation to a Marine Inspector.
46 CFR 176.25-5
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 19 August 2019
Resolved
At each initial and subsequent inspection for certification, the marine inspector shall view the vessel afloat and shall conduct the following tests and inspections of the hull structure and its appurtenances:
Examine all wheatertight closures above deck. Marine Inspector observed a small hole in the vicinity of the operating station. Fix the hole. Prove intergrity.
46 CFR 176.25-5
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 August 2019
Resolved
Employers must maintain records of chemical tests as provided in 49 CFR 40.333 and must make these records available to Coast Guard officials upon request.(b) The records shall be sufficient to: (1) Satisfy the requirements of §§ 16.210(b) and 16.220(c) of this part.
(2) Identify the total number of individuals chemically tested annually for dangerous drugs in each of the categories of testing required by this part including the annual number of individuals failing chemical tests and the number and types of drugs for which individuals tested positive. Documentation shall be available upon request. Provide documentation attesting to your drug and alcohol testing program.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 1 October 2018
Resolved
CLSN: Vsl is not broadcasting a Call Sign, ZERO DRAFT: no static draft information
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 15 September 2017
Resolved
Provide operable stern light.
Lifesaving › Inflatable Buoyant Apparatus › Stowage
Issued 15 September 2017
Resolved
Correctly labeled hydrostatic release expiration date on IBA
Electrical › Electrical Distribution System (service) › Cable
Issued 15 September 2017
Resolved
Properly secure cable chaffing on steering gear.
Engineering › Bilge Water Management System › Manifold
Issued 15 September 2017
Resolved
Properly label bilge manifold.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 15 September 2017
Resolved
Remove trash can sitting over emergency escape hatch
Stability › Watertight Integrity › General
Issued 2 November 2016
Resolved
Replace stbd shaft seal.
Construction/Loadline › Penetrations › Weld
Issued 29 June 2016
Resolved
Make forepeak hatch watertight, minor leak at the 7 o'clock position while looking forward. The deck has an area of very thin steel that will need to be replaced at the drydock.
Engineering › Diesel Engine (propulsion-direct drive) › Block
Issued 9 September 2010
Resolved
Ensure proper tightening of motor mount nuts on port and starboard aft, outboard mount bolts.
Electrical › Electrical Distribution System (service) › Wiring
Issued 9 September 2010
Resolved
Properly wire potable water pump to vessel electrical system.
Engineering › Fuel Oil Service System › Filter
Issued 9 September 2010
Resolved
Ensure Racor drain plugs are UL approved.
Engineering › Steering Gear System › Yoke
Issued 9 September 2010
Resolved
Ensure proper operation of starboard steering gear stop.
Documentation › Logs/Records › Drug Test Records
Issued 23 March 2010
Resolved
Company does not have a Substance Abuse Professional (SAP) name and contact information, as required by 49 CFR 40.287.
Electrical › Lighting (service) › Lighting Fixture
Issued 16 July 2009
Resolved
Provide protective covers for exposed light bulbs in forward closet and main passenger compartment.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 16 July 2009
Resolved
Label to 70 amp breaker with respective load ( electric heater distribution panel).
Electrical › Electrical Distribution System (service) › Junction Box
Issued 16 July 2009
Resolved
Cover exposed junction box in galley closet.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 16 July 2009
Resolved
Provide 18 foot lines for lights on all lifefloats.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 5 June 2006
Resolved
Re-new expired Epirb hydrostatic release.
Electrical › Lighting (service) › Lighting Fixture
Issued 5 June 2006
Resolved
Provide protective cover for port overhead light in pilot house.
Navigation › Piloting/Steering › US Coast Pilot
Issued 5 June 2006
Resolved
Provided up to date US Coast Pilot.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 5 June 2006
Resolved
Provide up to date Coast Guard Light List.
Navigation › Piloting/Steering › Marine Charts
Issued 5 June 2006
Resolved
Provide up to date and properly corrected Navigational Charts.
Stability › Watertight Integrity › General
Issued 5 June 2006
Resolved
Attach forepeak hatch with safety chain.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 5 June 2006
Resolved
Quarterly man overboard drill was not conducted on this vessel for the second quarter of calendar year 2006. Company training officer showed me a print out query of drills and training conducted for this vessel and it revealed no drill was completed for the second quarter of calendar year 2006.
Engineering › Bilge Water Management System › Piping
Issued 5 June 2006
Resolved
Provide proper operation of entire bilge suction system from all compartments.
Engineering › Steering Gear System › Rudder Stock
Issued 5 June 2006
Resolved
Repair as necessary, both rudder posts leak water excessively when vessel is turned hard over to each port and stbd sides.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 12 July 2005
Resolved
Renew 1 child PFD.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 12 July 2005
Resolved
Install insulation on the starboard exhaust piping.
Construction/Loadline › Hull › Weld
Issued 27 June 2005
Resolved
Repair port side splash rail in way of midship, FWD. (Bent and cracked weld.)
Construction/Loadline › Hull › Weld
Issued 27 June 2005
Resolved
Repair cracked weld in way of FWD void under galley, FWD bulkhead.
Electrical › Electrical Distribution System (service) › Wiring
Issued 27 June 2005
Resolved
Properly wire high level alarm to MSD holding tank. (Wire Nuts)
Construction/Loadline › Hull › Bottom Plating
Issued 27 June 2005
Resolved
Provide hull gauging to bottom hull plate aft of sewage tank.
Stability › Watertight Integrity › General
Issued 27 June 2005
Resolved
Make FWD bulkhead in engine room water tight in way of stuffing tubes and missing bolt, center line/starboard.
Stability › Watertight Integrity › General
Issued 27 June 2005
Resolved
Make aft engine room bulkhead watertight in way of STBD exhaust penetrations.
Stability › Watertight Integrity › General
Issued 27 June 2005
Resolved
Patch hole in FWD engine room bulkhead in way of STBD side FWD by wash down hose upper.
Engineering › Bilge Water Management System › Strainer
Issued 27 June 2005
Resolved
Repair lazarrate bilge suction strainer.
Lifesaving › Lifefloat › Lifeline
Issued 9 August 2004
Resolved
Replace tending lines and float light halyards on the 4 life floats.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 9 August 2004
Resolved
Restock missing contents in first aid kit.
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 9 August 2004
Resolved
Replace expired batteries in 3 adult PFD's.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 9 August 2004
Resolved
Repair the STBD running light.
Fire Fighting › Fire Bucket › Quantity
Issued 9 August 2004
Resolved
Provide fire buckets.
Engineering › Bilge Water Management System › Pump
Issued 9 August 2004
Resolved
Provide portable bilge pump.
Electrical › Lighting (service) › Lighting Fixture
Issued 9 August 2004
Resolved
Remove or repair light fixture in way of the bottom bunk port side.
Engineering › Bilge Water Management System › Valve
Issued 9 August 2004
Resolved
Replace handle on the fwd bilge suction valve in way of the crew space bilge.
Navigation › Piloting/Steering › Compass Deviation Table
Issued 28 August 2003
Resolved
Provide updated compass deviation table. LEGACY COMPONENT DESC: Compass Deviation Table
Stability › Watertight Integrity
Issued 25 August 2003
Resolved
Provide new gaskets for port and starboard engine space hatches. LEGACY COMPONENT DESC: Engine space hatches
Electrical › Electrical Distribution System (service) › Wiring
Issued 25 August 2003
Resolved
Cap or remove dead-end wire located under steering consol in pilot house.
Electrical › Electrical Distribution System (service)
Issued 7 July 2003
Resolved
Provide plans to replace starting battery cables with marine grade type. LEGACY COMPONENT DESC: Cable
Construction/Loadline › Hull
Issued 7 July 2003
Resolved
Provide plans to repair as new the steel below the shaft packing, port and starboard, where keel coolers are leaking into the engine room. LEGACY COMPONENT DESC: Hull Plating
Construction/Loadline › Hull
Issued 7 July 2003
Resolved
Provide gauging on the hull in the lazarette, to provide representative hull thickness throughout. LEGACY COMPONENT DESC: Bottom Plating
Engineering › Shafting/Propeller Arrangements
Issued 7 July 2003
Resolved
Replace as new cutlass bearings on both shafts.
Construction/Loadline › Hull
Issued 7 July 2003
Resolved
Repair as new area below each shaft packing in engine room above keel coolers
Electrical
Issued 4 June 2002
Resolved
Remove deadended wire from cabin top.
Engineering › Bilge Water Management System
Issued 4 June 2002
Resolved
Prove proper operation of fixed bilge pumping system. LEGACY COMPONENT DESC: Piping
Communications › Radio Communications
Issued 4 June 2002
Resolved
Vessel restricted to 3 miles from shore until EPIRB is provided. LEGACY COMPONENT DESC: EPIRB
Navigation
Issued 6 July 2001
Resolved
Conduct operational tests and drills in the presense of a Coast Guard Marine Inspector.
Lifesaving
Issued 15 July 2000
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Engineering
Issued 8 August 1997
Resolved
REPLACE PORT CUTLASS BEARING PRIOR TO REENTERING WATER
Accommodation/Occupational Safety
Issued 8 August 1997
Resolved
PROVIDE PLANS FOR INSTALLATION OF NEW MSD HOLDING TANK TO REPLACE PREVIOUSLY EXISTING TANK.
Engineering
Issued 8 August 1997
Resolved
PROVIDE PLANS FOR TURNING OF MAIN ENGINE EXHAUSTS TO EXIT SIDE OF VESSEL VICE STERN,
Construction/Loadline
Issued 8 August 1997
Resolved
PROVIDE COPY OF GAUGING REPORT
Construction/Loadline
Issued 8 August 1997
Resolved
REPAIR/REPLACE CROSS DECK ANGLE IRON (3) IN LAZZERETTE
Navigation
Issued 6 September 1996
Resolved
REPAIR AND REMOUNT STERNLIGHT.
Unknown
Issued 6 September 1996
Resolved
REAPIR/REPLACE NON-SKID ON DECK PRIOR TO COMPLETION OF NEXT DRYDOCK.
Electrical
Issued 6 September 1996
Resolved
PROVE PROPER OPERATION OF MAIN GENERATOR OVERSPEED TRIP.
Construction/Loadline
Issued 6 September 1996
Resolved
REPAIR DOGS AND STOPS ON CABIN HATCH.
Accommodation/Occupational Safety
Issued 10 February 1995
Resolved
REWELD/REPAIR AFT HAND RAIL CENTER SUPPORT.
Deck/Cargo
Issued 10 February 1995
Resolved
PROVIDE TOTAL OF 300 FEET OF 1/2" ANCHOR LINE, PRIOR TO CARRYING PASSENGERS
Electrical
Issued 10 February 1995
Resolved
REMOVE OR PROPERLY TERMINATE ELECTRICAL WIRE LOCATED BEHIND BLKHD OF TOILET
Construction/Loadline
Issued 10 February 1995
Resolved
REPLACE/REPAIR GASKET ON AFT STEERING HATCH, PRIOR TO CARRYING PASSENGERS.
Construction/Loadline
Issued 10 February 1995
Resolved
REMOVE WATER IN FOREPEAK FOR COMPLETION OF INSPECTION
Accommodation/Occupational Safety
Issued 10 February 1995
Resolved
REPAIR HOLE IN DECK AT BASE OF SUPPORT ON STBD HAND RAIL; #5 SUPPORT.
Accommodation/Occupational Safety
Issued 10 February 1995
Resolved
INSTALL SUITABLE CLOSURES FOR GATES ON MAIN DECK, PRIOR TO CARRYING PASSENGERS.
Accommodation/Occupational Safety
Issued 10 February 1995
Resolved
REMOVE 3 OVHD PANELS EACH SIDE IN ACCOMMADATION SPACE TO ALLOW INSPECTION OF MAIN DECK FROM BELOW OR PROVIDE ULTRASONIC TESTING; PRIOR TO CARRYING PASSENGERS AND PRIOR TO COMPLETION OF CREDIT DRYDOCK.
Construction/Loadline
Issued 10 February 1995
Resolved
CLEAN HULL FOR EXTERIOR INSPECTION
Accommodation/Occupational Safety
Issued 10 February 1995
Resolved
PROPERLY STENCIL; 1-ESCAPE HATCH BERTHING AREA, 2-ESCAPE HATCH FROM ACCOM SPACE TO PILOT HOUSE, 3-STBD SIDE E/R ESCAPE HATCH: PRIOR TO CARRYING PASSENGERS.
Construction/Loadline
Issued 10 February 1995
Resolved
ENSURE PROPER OPERATION OF DOGS ON FWD ESCAPE HATCH, PRIOR TO CARRYING PASSENGERS.
Construction/Loadline
Issued 10 February 1995
Resolved
SEAL HOLES IN STBD AFT BULKHEAD OF PILOT HOUSE
Engineering
Issued 10 February 1995
Resolved
INSTALL LOW SUCTION VENT DUCT FOR ENGINE ROOM
Construction/Loadline
Issued 10 February 1995
Resolved
REPAIR WASTED METAL FOR STBD ENGINE ROOM HATCH AND AFT STEER HATCH, PRIOR TO CARRYING PASSENGERS.
Accommodation/Occupational Safety
Issued 10 February 1995
Resolved
REPLACE BROKEN WINDOW #3 STBD LOCATED IN ACCOMMODATION SPACE.
Electrical
Issued 10 February 1995
Resolved
REMOVE OR PROPELY TERMINATE ELECTRICAL WIRE LOCATED BEHIND BLKHD OF KITCHENAREA BEHIND HEATER.
Construction/Loadline
Issued 10 February 1995
Resolved
ENSURE PROPER OPERATION OF DOG ON PILOT HOUSE DOOR
Documentation
Issued 22 June 1993
Resolved
PROVIDE ORIGINAL CERTIFICATE OF INSPECTION.
Documentation
Issued 22 June 1993
Resolved
PROVIDE EMERGENCY CHECK OFF LIST.
Construction/Loadline
Issued 22 June 1993
Resolved
REPAIR 1/4" HOLE IN BOW (WELD BLOW THROUGH) IN ACCORDANCE WITH CG APPROVED REPAIR PLANS.
Construction/Loadline
Issued 22 June 1993
Resolved
REPAIR FRACTURED FRAME (1st FRAME FORWARD OF COLLISION BULKHEAD STBD SIDE).REPAIR AT NEXT DRYDOCK.
Construction/Loadline
Issued 19 June 1992
Resolved
CLEAN ENGINE ROOM BILGE.
Accommodation/Occupational Safety
Issued 19 June 1992
Resolved
REPAIR/REMOVE/REPLACE MSD.
Construction/Loadline
Issued 19 June 1992
Resolved
REPLACE RING GASKET ON THE FORPEAK HATCH COVER, MAKE WATERTIGHT.
Accommodation/Occupational Safety
Issued 15 November 1991
Resolved
REMOVE DIRECT OVER BOARD DISCHARGE LINE FROM TOILET. CONNECT TYPE II MSD_x001C_ AS PER MANUFACTURES INSTRUCTIONS, PROVE OPERATION AS PER MANUFACTURES_x001C_ APPROVAL. TOILET TO BE SECURED UNTIL COMPLETED. VESSEL LIMITED TO 30 MIN._x001C_ RUNS.
Construction/Loadline
Issued 15 November 1991
Resolved
INSTALL KEEL COOLER VALVES AT GENERATOR AND MAIN ENGINES THROUGH HULLS.
Engineering
Issued 8 November 1990
Resolved
STENCIL FUEL SHUT-OFF LOCATION.
Construction/Loadline
Issued 8 November 1990
Resolved
REMOVE OR RECONNECT TRANSDUCER ASSEMBLY IN MIDSHIPS VOID.
Construction/Loadline
Issued 8 November 1990
Resolved
STENCIL "EMERGENCY ESCAPE, DO NOT BLOCK" OUTSIDE THE ESCAPE.
Electrical
Issued 8 November 1990
Resolved
PROVIDE COVERS FOR REGULAR AND EMERGENCY LIGHT, WHERE MISSING IN PASSENGER SALON.
Electrical
Issued 8 November 1990
Resolved
REPLACE BULB IN LIGHT, STBD SIDE MAIN SALON.
Construction/Loadline
Issued 8 November 1990
Resolved
REGAUGE HULL TO PROVE PLATE THICKNESS IS SATISFACTORY, OR PROVIDE ACCETABLE REPAIR PROCEDURES PROPOSALS UPON EVIDENCE OF UNACCEPTABLE WEAR.
Fire Fighting
Issued 8 November 1990
Resolved
PROVIDE EMERGENCY FIRE PUMP WITH SUFFICIENT SUCTION AND DISCHARGE HOSE (AT LEAST 5 FT OF SUCTION AND 20 FT OF DISCHARGE).
Documentation
Issued 8 November 1990
Resolved
PROVIDE VESSEL WITH MARPOL PLACARD.
Documentation
Issued 8 November 1990
Resolved
PERMANENTLY MOUNT CERTIFICATE OF INSPECTION AND STABILITY LETTER IN PILOT- HOUSE.
Electrical
Issued 8 November 1990
Resolved
PROVIDE GUARD FOR E/R LIGHT, WHERE MISSING (STBD SIDE).
Fire Fighting
Issued 8 November 1990
Resolved
FABRICATE AND INSTALL GUARD OVER PULLEY FOR FIRE/BILGE PUMP.
Fire Fighting
Issued 8 November 1990
Resolved
SERVICE PORTABLE FIRE EXTINGUISHERS.
Construction/Loadline
Issued 8 November 1990
Resolved
PROVIDE THE E/R AND LAZARETTE HATCHES WITH A SECURING DEVICE TO HOLD THEM IN THE OPEN POSITION.
Engineering
Issued 8 November 1990
Resolved
REPAIR EXHAUST LEAK ON STBD MAIN ENGINE.
Deck/Cargo
Issued 12 April 1990
Resolved
PROVIDE VESSEL WITH 300 FT OF ANCHOR LINE.
Construction/Loadline
Issued 12 April 1990
Resolved
PROVIDE MSO SAN FRANCISCO ORIGINAL SIDE SHELL AND BOTTOM PLATE SCANTLINGS. PROVIDE COPY OF FINAL GAUGE REPORT, AND HULL REPAIR INSERTS.
Navigation
Issued 1 February 1990
Resolved
PROVE OPERATION OF GYRO COMPASS
Documentation
Issued 1 February 1990
Resolved
PROVIDE PROPER DOCUMENTATION TO PROVE SATISFACTORY RADIO INSTALLATION IN ACCORDANCE WITH FCC REGULATIONS AND OBTAIN CURRENT FCC RADIOTELEPHONY CERTIFICATE.
Engineering
Issued 1 February 1990
Resolved
DOUBLE NUT/PIN ALL THROTTLE CONTROL LINKAGES.
Construction/Loadline
Issued 1 February 1990
Resolved
REGAUGE HULL TO PROVE PLATE THICKNESSES ARE SATISFACTORY OR PROVIDE ACCEPTABLE REPAIR PROPOSALS UPON EVIDENCE OF UNACCEPTABLE WEAR.
Engineering
Issued 1 February 1990
Resolved
REPLACE AND PROVE OPERATION OF BOTH PORT AND STARBOARD MAIN ENGINE WATER TEMPERATURE GUAGES IN WHEELHOUSE.
Engineering
Issued 1 February 1990
Resolved
INSTALL INSULATION ON AUX EXHAUST LINE IN LAZARETTE.
Accommodation/Occupational Safety
Issued 1 February 1990
Resolved
EXTEND ONE OF THE EXHAUST LINES IN ENGINE ROOM TO NEAR THE BILGE IAW 46CFR182.20-45(C)
Electrical
Issued 1 February 1990
Resolved
PROVIDE DEAD COVER ON CIRCUT BREAKER BOX IN GALLEY
Navigation
Issued 20 July 1989
Resolved
SWING SHIP AND PROVIDE DEVIATION CARD FOR MAGNETIC COMPASS.
Navigation
Issued 20 July 1989
Resolved
Unknown Component - Unknown Cause/Condition
Construction/Loadline
Issued 22 June 1989
Resolved
MANHOLE COVER FOR FORE PEAK TANK HAS NO CAPTIVE DEVICE. PROVIDE CAPTIVE CHAIN OR OTHER DEVICE TO PREVENT ITS LOSS. 46CFR171.124(B)(2)
Lifesaving
Issued 22 June 1989
Resolved
PROVIDE 10 LIFE PRESERVERS TO BRING TOTAL LIFE PRESERVERS ONBOARF TO 56. VESSEL IS LIMITED TO TOTAL PERSONS OF 46 UNTIL COMPLIANCE.
Construction/Loadline
Issued 22 June 1989
Resolved
BILGE SUCTION LINES FOR FORE PEAK AND FORWARD ACCOMMODATION SPACE MISSING STRAINERS. PROVIDE BILGE SUCTIONS WITH SUITABLE STRAINERS HAVING AN OPEN AREA NOT LESS THAN THREE (3) TIMES THE AREA OF THE BILGE PIPE. 46CFR182.25(B).
Unknown
Issued 22 June 1989
Resolved
PROVIDE SUITABLE FASTENING DEVICE TO SECURE GATE IN RAIL PORT AND STBD OPENDECK.
Construction/Loadline
Issued 22 June 1989
Resolved
LONGITUDINAL STIFFENERS INWAY OF SIDE SHELL STBD SIDE WASTED. CROP TO GOODSTEEL AND RENEW.
Navigation
Issued 22 June 1989
Resolved
MAGNETIC COMPASS LOSS DURING TRANSIT TO VALDEZ. FIT VESSEL WITH SUITABLE COMPASS. 46CFR184.20
Construction/Loadline
Issued 22 June 1989
Resolved
NON RETURN VALVE FOR FORE PEAK BILGE SUCTION LINE MALFUCTION. REPAIR OR RENEW NON RETURN VALVE.
Engineering
Issued 18 August 1988
Resolved
BEFORE OPERATION OF VESSEL, SECOND RE-INSPECTION HAS TO BE COMPLETED TO THESATISFACTION OF AN ATTENDING COAST GUARD MARINE INSPECTOR.
Lifesaving
Issued 30 July 1986
Resolved
PROVIDE APPROVED LIGHTS FOR (2) LIFE JACKETS THAT ARE OUT DATED.
Construction/Loadline
Issued 30 July 1986
Resolved
CROP AND RENEW TO GOOD METAL ALL WASTED TOP CABIN SHELL AND MAIN DECK AREA WHERE THE CABIN OVERHEAD MEETS THE MAN DECK ABOVE THE ENGINE ROOM (STEP AREA) ON THE PORT AND STBD SIDES.
Documentation
Issued 30 July 1986
Resolved
PLACE ON BOARD THE ORIGINAL DOCUMENTS INCLUDING THE DOCUMENTATION CERTIFICATE, THE CERTIFICATE OF INSPECTION, STABILITY LTR, EMERGENCY CHECK OFF LIST. ALSO, PROVIDE A COPY OF EACH TO THE [name withheld], AK.
Lifesaving
Issued 30 July 1986
Resolved
PROVIDE HYDRO RELEASE FOR BOTH RAFTS
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.