MAURY USCG vessel records Sign in
← All vessels

ONEGO TRAMPER

ONEGO TRAMPER is a 1997 freight ship. The Coast Guard has recorded 38 inspections since 1997, most recently in September 2008, along with 43 deficiencies — 2 with no resolution recorded — and 14 operational controls.

Records from 1997 to 2008. Most recent: inspection, 26 September 2008.

Built
1997
Last inspected
26 September 2008
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9043122 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
467576
Flag
ANTIGUA AND BARBUDA
—
Maury page id
psix-467576

Inspections, by type

…with no type recorded22
…past their stated due date2
Years with a record 7 calendar years (1997–2008)
The 38 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it2649 - Convention (Subpart B), Net Ton
6459 - Convention (Subpart B), Gross Ton
8558 - Dead Weight, Ton
12304 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 38

26 September 2008 ISPS I Exam · Deficiency Check · PII Safety Exam
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3336349
18 September 2008 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3327301
15 August 2008 MARPOL Annex I Examination · Ballast Water Examination · ISPS I Exam · NPV Safety Exam · MARPOL Annex V Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3293854
15 August 2008 Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 3299084
14 August 2008 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3293855
26 July 2008 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3276021
2 July 2008 MARPOL Annex V Examination · Ballast Water Examination · ISPS II Exam · NPV Safety Exam · MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3246746
20 December 2007 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3118862
11 December 2007 Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3113588
5 December 2007 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3109889
29 October 2007 Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3083122
12 October 2007 In-Service Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3078710
12 October 2007 Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3078726
11 October 2007 PII Safety Exam · MARPOL Annex V Examination · ISPS II Exam · MARPOL Annex I Examination · Ballast Water Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3077624
27 June 2007 Type not recorded
No type recorded · Station Miami Beach · USCG Southeast District (CGD-SE) · Activity 2975959
26 June 2007 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2974995
24 February 2007 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2876906
24 February 2007 Random ISPS/MTSA-No PSC
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2876914
31 January 2007 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2865817
19 January 2007 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2858894
12 October 2006 Random ISPS/MTSA-No PSC
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2799291
25 September 2006 Type not recorded
No type recorded · Station Fort Lauderdale · USCG Southeast District (CGD-SE) · Activity 2786759
24 September 2006 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2785785
27 August 2006 ISPS II Exam · PII Safety Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2761578
16 August 2006 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2749452
1 March 2006 Type not recorded
No type recorded · Maritime Safety & Security Team Miami (91114) · Activity 2594282
8 February 2006 Ballast Water Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2581621
6 February 2006 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2580114
19 January 2006 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2569209
7 October 2005 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2510136
29 September 2005 ISPS II Exam · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2503812
7 September 2005 PII Safety Exam · Ballast Water Examination · ISPS III Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2486362
22 November 1999 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 434907
17 September 1999 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 432848
19 March 1999 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 426653
5 December 1998 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 423362
12 December 1997 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 410927
26 November 1997 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 410380

Deficiency record · 43

Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 15 August 2008 Resolved
Owner/operator failed to prepare and submit a nontank vessel response plan IAW 33 U.S.C 1321(j)(5).
Action required: 705 - Other - as specified
Due 22 August 2008
Resolved 26 September 2008
Personnel › Certificates/Documents/Licenses › STCW Endorsement
Issued 15 August 2008 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Due 15 August 2008
Resolved 22 August 2008
Resolution: Received class report stating the C/O''s Flag State endorsement has been provided.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 15 August 2008 No resolution recorded
Vessel's oily water separator (OWS) could not be operated, this was because both inlet and outlet piping has been cut rendering inoperative. However, the vessel IOPP shows that the vessel has an operative oily water separator. Provide report attesting to the proper operation of the OWS from the attending classification society.
Action required: 705 - Other - as specified
Due 21 October 2008 — due date passed with no resolution recorded
Pollution Prevention/Response › Prevention Equipment › Incinerator, Shipboard
Issued 15 August 2008 No resolution recorded
Vessels incinerator was found inoperable and handles to access doors were welded closed. Provide report attesting to the proper operation of the incinerator from the attending classification society.
Action required: 705 - Other - as specified
Due 21 October 2008 — due date passed with no resolution recorded
Construction/Loadline › Hull › Longitudinal Frame
Issued 15 August 2008 Resolved
Damage to the vessel's hull was discovered internally, where hull plating had been inset, causing deflection and cracked welds in frames 43 through 47 on the port side on the intermediate deck/pipe tunnel. Make permanent repairs and provide report from the attending classification society.
Action required: 705 - Other - as specified
Due 15 August 2008
Resolved 22 August 2008
Resolution: Received class report attesting to the satisfactory repairs by the attending classification society.
Engineering › Steering Gear System › Feedback Unit
Issued 15 August 2008 Resolved
During the steering test while in bridge control, the rudder position varied 2 to 5 degrees showing that the feedback units were not properly synchronized. Prior to movement provide class report attesting to the proper operation of steering control system.
Action required: 705 - Other - as specified
Due 15 August 2008
Resolved 22 August 2008
Resolution: Received class report stating repairs to the steering gear have been made and tested to the satisfaction of the attending classification society.
Communications › Alarms/Indicators › Steering Failure Alarm System
Issued 15 August 2008 Resolved
During the steering test, when power was secured to the steering gear power units, audible and visual alarms failed to function on the navigation bridge. Prior to movement provide class report attesting to the proper operation of the steering gear power units failure alarms. SOLAS 74a II-1/29
Action required: 705 - Other - as specified
Due 21 September 2008
Resolved 26 September 2008
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 15 August 2008 Resolved
During the inspection of the vessels records the PSCO found that a static liquid pressure test to the bunker lines has not been conducted in accordance with 33 CFR 156.170. Vessel is prohibited from bunkering in US waters until the required test is conducted and documented. 33 CFR 155.820
Action required: 705 - Other - as specified
Due 15 August 2008
Resolved 22 August 2008
Resolution: Received class report stating a satisfactory hydro static test had been conducted.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 15 August 2008 Resolved
Vessel does not have a Coast Guard approved Non-tank Vessel Response Plan onboard. 33 U.S.C. 1321(j)(5)
Action required: 705 - Other - as specified
Resolved 20 August 2008
Resolution: Received copy of the CG approved NT-VRP dated 18JUL08 (control #03660), expiration date is 27APR09.
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 12 October 2007 Resolved
Provide additional assist tugs mitigating the failure of the bow thruster listed on the maneuvering characteristics for 13 Oct 2007 arrival and 13 Oct 2007 departure to St. Croix, U.S. Virgin Islands.
Condition: Unknown
Due 12 October 2007
Resolved 13 October 2007
Resolution: Deficiency Cleared
Deck/Cargo › Cargo Stowage › General
Issued 12 October 2007 Resolved
Provide calss report addressing the following: Ensure vessel stability program is receiving correct measurements with regards to weights of cargo being loaded and offloaded, inputed by ship personnel. Ensure there is a system in place within the safety management system to verify weight units prior to entering into the stability computer.
Action required: 705 - Other - as specified
Due 27 October 2007
Resolved 11 December 2007
Resolution: Received class report attesting to the proper implementation of loading and ballasting manual and the responsibilities of the SMS for stability.
Fire Fighting › Nozzles › Type
Issued 11 October 2007 Resolved
Numerous fire nozzles are not adjustable.(Varible). Class society has addressed problem to be fixed @ survey 28,29 OCT. Provide class report to USCG.
Condition: Unknown
Action required: 705 - Other - as specified
Due 25 October 2007
Resolved 11 December 2007
Resolution: received class report attesting to proper installation.
Fire Fighting › Fire Pumps › Pressure
Issued 11 October 2007 Resolved
Emergency Fire Pump unable to produce adequete water pressure.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 11 October 2007
Resolution: Chief Engineer bled air from pump and isolated valves. This took over 30 minutes to accomplish.
Electrical › Electric Generation Source (emergency) › Number of Sources
Issued 11 October 2007 Resolved
Emergency generator doesn't have two seperate sources of power. (only one set of batteries). Have class society address problem and provide corrective action report to U.S Coast Guard.
Condition: Unknown
Action required: 705 - Other - as specified
Due 25 October 2007
Resolved 11 December 2007
Resolution: recieved class report attesting to proper installation of secondary means of starting.
Engineering › Thrusters › Motor
Issued 11 October 2007 Resolved
Bow Thruster overheating light indicated problem while in transit to pier. Vessel Master requested Tug assistance to moor . Alarm cleared while moored. Request problem be addressed with Class Society to ensure proper operation. Provide class report to USCG.
Condition: Unknown
Action required: 705 - Other - as specified
Due 25 October 2007
Resolved 11 December 2007
Resolution: recieved class report attesting to proper repairs.
Engineering › Freshwater System (jacketwater cooling) › Fitting
Issued 29 September 2005 Resolved
1430 Excessive leaking from port side #2 SSDG J/W cooler end bell. SOLAS 74/78 I/II 50c
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 October 2005
Resolved 8 October 2005
Resolution: Rcd Class report attesting to repairs
Accommodation/Occupational Safety › Refrigeration (air conditioning) › General
Issued 29 September 2005 Resolved
0740 Sea water piping for A/C system has temporary soft patch repair (next to auxiliary boiler - upper level, next to aux bollard). SOLAS 74/78 I/II 50/c
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 October 2005
Resolved 8 February 2006
Engineering › Lubricating Oil Storage/Transfer System › Piping
Issued 7 September 2005 Resolved
REPLACE LAGGING ON OIL PURIFYING ROOM
Due 23 September 2005
Resolved 29 September 2005
Resolution: Performed a visual inspection of corrected deficiency.
Engineering › Generator (propulsion-electric) › Indicator Circuitry
Issued 7 September 2005 Resolved
SECURE THE WIRE ON THE OIL SENSORS OF GENERATORS
Due 23 September 2005
Resolved 29 September 2005
Resolution: Performed a visual inspection of corrected deficiency.
Engineering › Steam Boiler (auxiliary/waste heat) › Tube Header
Issued 7 September 2005 Resolved
REPAIR GLASS TUBE ON HOTWELL TANK ON AUXILIARY BOILER
Due 23 September 2005
Resolved 7 September 2005
Resolution: Performed a visual inspection of corrected deficiency.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 7 September 2005 Resolved
REPAIR/ REPLACE SWITCH OF CO2 RELEASSE CONTROL IN PAINT LOCKER
Due 23 September 2005
Resolved 29 September 2005
Resolution: Performed a visual inspection of corrected deficiency.
Construction/Loadline › Hull › Side Shell
Issued 7 September 2005 Resolved
INSET ON STBD SIDE BY THE SUPERSTRUCTURE BELOW MAIN DECK
Action required: 705 - Other - as specified
Due 7 June 2007
Resolved 7 June 2007
Resolution: RECEIVED CLASS REPORT. REPAIRED BY THE NEXT DRY DOCKING PERIOD
Electrical › Electric Supply System (service) › Cable
Issued 23 August 2005 Resolved
REPLACE STUFFING TUBE ON THE ELECTRICAL BOX FOR THE MOORING WINCHPORT & STARBOARD SIDE INSIDE STEERING ROOM.
Due 23 September 2005
Resolved 29 September 2005
Resolution: Sector San [name withheld] Division received statement from the master attesting to the effective repairs and replacement of stuffing tube.
Unknown
Issued 22 November 1999 Resolved
Two persons missing for the safe manning of the ship. Safe manning documentrequired 13 minimum personnel on board and only 11 were present. Flag waived there voyage to next port. All required number of people are supposed to be on board before leaving next port.
Condition: Unknown
Due 6 January 2000
Resolved 6 January 2000
Lifesaving
Issued 17 September 1999 Resolved
LIFERAFT OPERATING INSTRUCTIONS NOT POSTED IN VICINITY OF LIFERAFTS: PROVIDE OPERATING INSTRUCTIONS (SOLAS 74 [AMD] III/9.2)
Condition: Unknown
Due 22 November 1999
Resolved 22 November 1999
Lifesaving
Issued 17 September 1999 Resolved
LIFEBOAT NOT LABELED WITH VESSEL NAME AND PORT OF REGISTRY: LABEL LIFEBOAT (SOLAS 74 [AMD], III/41.9.2)
Condition: Unknown
Due 22 November 1999
Resolved 22 November 1999
Electrical
Issued 17 September 1999 Resolved
MISSING NONCONDUCTIVE MATTING IN FRONT OF EMERGENCY SWITCHBOARD: INSTALL NONCONDUCTIVE MATTING BY EMERGENCY SWITCHBOARD (SOLAS 74 [AMD], II-1/45.2)
Condition: Unknown
Due 22 November 1999
Resolved 22 November 1999
Engineering
Issued 17 September 1999 Resolved
CREW DID NOT OBTAIN READING OF <15 PPM DURING TEST OF OWS: CONDUCT TEST OFOWS TO SATISFACTION OF CERTIFICATE ISSUING AUTHORITY (MARPOL 73/78, ANNEX I/16)
Condition: Unknown
Due 22 November 1999
Resolved 22 November 1999
Fire Fighting
Issued 5 December 1998 Resolved
Repair and replace hose coupling on poop deck aft fire station.
Condition: Unknown
Due 19 March 1999
Resolved 19 March 1999
Documentation
Issued 5 December 1998 Resolved
Provide current medical examinations for the entire crew.
Condition: Unknown
Due 19 March 1999
Resolved 19 March 1999
Documentation
Issued 5 December 1998 Resolved
Provide correct oil transfer procedures.
Condition: Unknown
Due 19 March 1999
Resolved 19 March 1999
Navigation
Issued 5 December 1998 Resolved
Provide updated tidal current tables.
Condition: Unknown
Due 19 March 1999
Resolved 19 March 1999
Navigation
Issued 5 December 1998 Resolved
Provide correct maneuvering fact sheet with warning.
Condition: Unknown
Due 19 March 1999
Resolved 19 March 1999
Lifesaving
Issued 5 December 1998 Resolved
Repair or replace lifeboat aft battery charger cable.
Condition: Unknown
Due 19 March 1999
Resolved 19 March 1999
Lifesaving
Issued 5 December 1998 Resolved
Provide operating manual for PEBSO lifeboat.
Condition: Unknown
Due 19 March 1999
Resolved 19 March 1999
Lifesaving
Issued 5 December 1998 Resolved
Repair and replace emnbarkation lights on Accomodation Deck II.
Condition: Unknown
Due 19 March 1999
Resolved 19 March 1999
Lifesaving
Issued 5 December 1998 Resolved
Repair and replace embarkation lights on Accomodation deck I.
Condition: Unknown
Due 19 March 1999
Resolved 19 March 1999
Fire Fighting
Issued 5 December 1998 Resolved
Amend/correct both fire control plans to reflect current vsl name.
Condition: Unknown
Due 19 March 1999
Resolved 19 March 1999
Fire Fighting
Issued 5 December 1998 Resolved
Replace/install fore castle deck port side angle fire hydrant gasket.
Condition: Unknown
Due 19 March 1999
Resolved 19 March 1999
Navigation
Issued 26 November 1997 Resolved
Prove proper operation of steering gear alarms, as per SOLAS 92 amended chapter II-1 reg. 29.
Condition: Unknown
Due 28 November 1997
Resolved 4 December 1997
Navigation
Issued 26 November 1997 Resolved
Provide a recognizable means of indicating rudder angle in the steering gear room, as per SOLAS 92 amended chapter II-1 reg. 29.11.2.
Condition: Unknown
Due 28 November 1997
Resolved 4 December 1997
Navigation
Issued 26 November 1997 Resolved
Repair starboard steering pump, as per SOLAS 92 amended chapter II-1 reg. 29.
Condition: Unknown
Due 28 November 1997
Resolved 4 December 1997
Construction/Loadline
Issued 26 November 1997 Resolved
Provide "Oil Discharge Prohibited" signs, as per 33 CFR 155.450.
Condition: Unknown
Due 12 December 1997
Resolved 12 December 1997