← All vessels
GRACE
Freight Ship · General Dry Cargo Ship class · Built 1960s · USCG Southeast District (CGD-SE) · Other hulls named GRACE
GRACE is a 1960 freight ship. The Coast Guard has recorded 62 inspections since 2001, most recently in February 2024, along with 113 deficiencies and 35 operational controls.
Records from 2001 to 2024. Most recent: inspection, 26 February 2024.
- Built
- 1960
- Last inspected
- 26 February 2024
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 113 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
5089647 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
J8PM2
4676
Flag
SAINT VINCENT AND THE GRENADINES
—
Maury page id
psix-4676
Inspections, by type
…with no type recorded36
Years with a record
13 calendar years (2001–2024)
The 62 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it398 - Regulatory (Subpart C or D), Gross Ton
692 - Convention (Subpart B), Gross Ton
207 - Convention (Subpart B), Net Ton
692 - Convention (Subpart B), Gross Ton
207 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 62
26 February 2024
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7870115
26 February 2024
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7870120
4 August 2014
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4943468
25 June 2014
Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4899747
2 September 2011
Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4133986
8 February 2011
ISPS II Exam · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3941225
4 February 2011
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3939610
16 February 2010
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3666316
15 February 2010
Type not recorded
No type recorded · USCGC SHAMAL (WPC 13) · Activity 3686847
25 March 2009
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3437932
25 March 2009
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3440305
25 March 2009
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3440420
7 January 2009
ISPS I Exam · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3385260
5 January 2009
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3385263
15 November 2008
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3364588
12 November 2008
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3361964
26 August 2008
Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3309429
26 August 2008
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3311047
25 August 2008
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3308852
4 August 2008
ISPS II Exam · STCW 95 Exam · ILO-147 Exam · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3234585
11 June 2008
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3233881
9 June 2008
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3232186
17 May 2008
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3208996
23 April 2008
In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3193984
27 March 2008
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3172297
22 February 2008
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3151951
19 December 2007
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3118196
14 December 2007
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3115999
31 October 2007
MARPOL Annex V Examination · Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3049402
2 September 2007
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3045928
8 June 2007
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2955315
22 August 2006
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2755846
16 February 2006
ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2584225
16 February 2006
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2586461
14 February 2006
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2585284
9 February 2006
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2582570
25 January 2006
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2572981
12 December 2005
Ballast Water Examination · MARPOL Annex I Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2552887
7 December 2005
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2547416
7 December 2005
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2547881
6 December 2005
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2547048
22 September 2005
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2507863
16 September 2005
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2494413
23 August 2005
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2472086
19 August 2005
Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2467923
28 July 2005
ISPS II Exam · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2447272
6 June 2005
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2381333
12 November 2004
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2239887
1 July 2004
ISPS II Exam
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2117468
19 November 2003
Annual Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1950644
15 November 2003
Annual Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1948245
30 October 2003
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1938874
19 November 2002
Administrative Inspection
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1709273
15 November 2002
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1706154
17 October 2002
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1691143
24 September 2002
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1679594
17 September 2002
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1676798
22 August 2002
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1665089
11 February 2002
Annual Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1485329
7 February 2002
Administrative Inspection
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1484853
23 January 2002
Administrative Inspection
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1480704
1 March 2001
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 287701
Deficiency record · 113
Lifesaving › Lifebuoys › Immediately Available
Issued 2 September 2011
Resolved
CCSSC CH4/4.12.5.2 Lifebuoys should be so stowed as to be capable of being rapidly cast loose and not premanently secured in any way. Port side lifebuoy on bridge wing is unable to be relaeased due to a bent guard rail pressing on teh ring itself.
Engineering › Generator (propulsion-electric) › Cable
Issued 28 February 2011
Resolved
Exposed metal parts of electrical machines or equipment which are not intended to be live, but which are to become live should be earthed. Vessel generator has a moving belt and is not protected causing a safety issue. CCSSC 2.32.1.1
Operations/Management › Drills/Instruction › Fire
Issued 28 February 2011
Resolved
Training drills should as far as practicable be conducted as if there were an actual emergency. Ship's crew did not run a satisfactory fire drill. There was not any proper communication between the crew. Vessel is required to run a satisfactory fire drill prior to departure.
Construction/Loadline › Structures › Superstructure
Issued 28 February 2011
Resolved
ICLL AnnexI/Reg16.4: The means for securing and maintaining weather tightness shall ensure that the tightness can be maintained in any sea condition. Soft patch found on stbd side of superstructure; hole on galley door frame and hole on top deck hatch leading to galley.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 28 February 2011
Resolved
Vessel does not have a Master onboard. Vessel does not meet the minimum safe manning requirement. Also does not meet the GMDSS requirement of 02 GMDSS operators.
CCSSC 6.1.2.9
SOLAS 74 (09 Cons) Ch. V/Reg 14.1
Communications › Visual Communication › Signalling Lamp
Issued 28 February 2011
Resolved
Vessel does not have an aldis lamp onboard.
Electrical › Lighting (service) › Lighting Fixture
Issued 28 February 2011
Resolved
Ships should be designed, constructed, and maintained in compliance with electrical requirements of a class society which complies with IMO standards. Vessel has broken light fixtures; (1) Outside galley and (2) Emergency generator room not protecting from electrical current. CCSSC CH2 2.1.1
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 28 February 2011
Resolved
CCSS CODE CH1/Reg1.11.1: The condition of ship's equipment is to be maintained to conform with the provisions of this code to ensure that the ship will remain fit to proceed to sea without danger to persons. Vessel's lifebuoys do not have adequate reflective tape around the entire buoy.
Fire Fighting › Miscellaneous Items › Waste Receptacles
Issued 28 February 2011
Resolved
All exposed surfaces including decks in concealed or in accessible spaces should have low flame-spread characteristics. Flamable rags stored in emergency generator room, not in proper waste receptacles. CCSSC CH3 3.16.3.1
Communications › Radio Communications › EPIRB
Issued 28 February 2011
Resolved
Every ship of greater than 300GT should carry at least one EPIRB. Vessel has an expired EPIRB. 74 SOLAS 09 CONS. CHIV Reg. 7.6
Operations/Management › Vessel Safety Management › Company Responsibilities/Authority
Issued 28 February 2011
Resolved
74SOLAS09Cons.Ed CHIX/Reg5; ISM PartA/3.3. The company is responsible for ensuring adequate resources and shore based support are provided to enable the designated person or persons to carry out their functions. Vessel lacks structured and documented system enabling personnel to implement effective safety policy, proper manning, proper training of personnel and proper working conditions...
Fire Fighting › Fixed Fire Detection System › Detector/Call Point Grouping
Issued 9 February 2011
Resolved
Fixed fire detection and alarm systems required by this chapter shall as far as practicable comply with the regulations of 1974 SOLAS convention. Multiple detectors inoperable.
Lifesaving › Rescue Boat › Hull (rigid)
Issued 9 February 2011
Resolved
Rescue boat should be of sufficient strength and rigidity. Multiple cracks found in the fiberglass structure of the rescue boat hull.
Lifesaving › Embarkation Appliances/Stations › Side Ropes
Issued 9 February 2011
Resolved
The side ropes of the ladder shall consist of two uncovered manila ropes not less than 65mm in circumference. Starboard embarkation ladder rope is wasted.
Construction/Loadline › Structures › Superstructure
Issued 9 February 2011
Resolved
Satisfactory means shall be provided for the protection of the crew in getting to and from their quarters, machinery spaces, and all other parts used in the necessary work of the ship. Multiple ladders wells are wasted.
Construction/Loadline › Hull › Hull Plating
Issued 8 February 2011
Resolved
After any survey no change shall be made in the structure, equipment, arrangements, material or scantling. Two inch hole found on the port side of the hull, above the deck line.
Construction/Loadline › Hull › Hull Plating
Issued 8 February 2011
Resolved
After any survey, no change shall be made in the structure, equipment arrangements, material, or scantling. Quart inch hole found on the starboard side of the engine room across from the electrical panel below the deck line. Another hole found forward, on the #2 cargo hold.
Construction/Loadline › Structures › Scuttle
Issued 8 February 2011
Resolved
Sidescuttles to space within enclosed superstructure shall be arranged so that they can be secured watertight. Multiple sidescuttels cannot be secured shut due to painted gaskets, missing gaskets or wires passing through.
Personnel › Manning/Qualifications › Medical Fitness
Issued 8 February 2011
Resolved
Candidates shall hold a valid documentation attesting to their medical fitness. AB (Sanley Rubio) could not provide a valid medical certificate.
Engineering › Sea-water System (primary cooling) › Piping
Issued 8 February 2011
Resolved
The condition of the ship and its equipment is maintained to conform with the provisions of this code to ensure that the ship in all respect is fit to proceed to sea. The raw water(cooling) line and the #1 cylinder fuel line are leaking.
Construction/Loadline › Structures › Machinery Space Opening
Issued 8 February 2011
Resolved
After any survey of the ship under Article 16 has been completed, no change shall be made in the structure material covered by the survey. The vent to the steering gear room has a 1/2 inch by 1.5 inch hole in the underside of the gooseneck.
Lifesaving › Rescue Boat › Propulsion Engine
Issued 8 February 2011
Resolved
Rescue boats shall be capable of manoeuvring at a speed of at least 6 knots and maintaining that speed for a period of 4 h. Rescue boat engine is inoperable.
Lifesaving › Rescue Boat Equipment › Bailer
Issued 8 February 2011
Resolved
Life-saving appliances should comply with the technical specifications of the LSA code. Rescue boat missing required equipment.
Documentation › Certificates/Documents › Document of Compliance (ISM)
Issued 7 January 2009
Resolved
SOLAS 74 4.1 CH 9 - Provide valid recept of application or endorcement from St. Vincent flag for Master.
Documentation › Certificates/Documents › Document of Compliance (ISM)
Issued 7 January 2009
Resolved
Provide valid Document of Compliance.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 26 August 2008
Resolved
Owner/operator failed to prepare and submit a nontank vessel response plan IAW 33 U.S.C 1321(j)(5).
Engineering › Generator (propulsion-electric) › Cable
Issued 4 August 2008
Resolved
Provide and implement solution to ship service diesel generators and emergency generator locations and operability to comply with Caribbean Cargo Ship Safety Code.
Engineering › Generator (propulsion-electric) › Cable
Issued 4 August 2008
Resolved
Provide flag report attesting to proper installation and operation of engine room generator.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 4 August 2008
Resolved
Safety guard for moving equipment between engine and generator on the emergency generator is not available. Repair safety guard.
Lifesaving › Inflatable Liferafts › Not on Board
Issued 4 August 2008
Resolved
Two liferafts are not onboard vessel due to being serviced. Provide Sector Miami with a copy of the letter from the liferaft servicing company attesting to servicing and return to vessel.
Lifesaving › Rescue Boat › Markings
Issued 5 September 2007
Resolved
Vessel name and homeport not stenciled on rescue boat.
Lifesaving › Hand Flares › Expired
Issued 5 September 2007
Resolved
Expired pyrotechnics on bridge.
Navigation › Piloting/Steering › Marine Charts
Issued 5 September 2007
Resolved
No corrected/updated charts.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 5 September 2007
Resolved
Stenciling and retro-tape worn on lifebuoys.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 5 September 2007
Resolved
No cover for paint locker vent to maintain fire suppression capabilities.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 5 September 2007
Resolved
Provide covers for main ship diesel generator
Documentation › Certificates/Documents › Cargo Ship Safety Certificate
Issued 5 September 2007
Resolved
Cargo Ship Safety Certificate expired.
Deck/Cargo › Cargo Stowage › General
Issued 5 September 2007
Resolved
No wedges provided for tarp covers to maintain weather tight integrity for cargo holds.
Electrical › Lighting (service) › Lighting Fixture
Issued 5 September 2007
Resolved
Missing light bulb and cover for light in emergency generator space.
Stability › Weathertight Integrity › General
Issued 5 September 2007
Resolved
Gasket for hatch leading to emergency generator room wasted, does not maintain weather tight integrity.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Nozzle, Injection (fuel injection)
Issued 5 September 2007
Resolved
#1 ship diesel generator has a leak in fuel line.
Navigation › Collision/Grounding Avoidance › Danger Messages
Issued 5 September 2007
Resolved
Vessel missing Navtex on bridge.
Electrical › Electric Generation Source (emergency) › Generator Cable
Issued 5 September 2007
Resolved
Cable from #1 Ship Service Diesel Generator to electrical bank not properly installed.
Operations/Management › Drills/Instruction › Fire
Issued 5 September 2007
Resolved
Vsl did not perform a satisfactory fire drill.
Engineering › Bilge Water Management System › Pump
Issued 5 September 2007
Resolved
Engine room bilge is full of water and bilge slops. Vsl needs to remove slops prior to next US port of call after sailing foreign.
Engineering › Freshwater System (jacketwater cooling) › Drainage
Issued 5 September 2007
Resolved
Engine has coolant leak that needs to be reviewed and addressed by class for repairs if necessary.
Lifesaving › Liferaft Equipment › Food Ration
Issued 5 September 2007
Resolved
Vsl does not have adequate food and water supplies for abandon ship.
Navigation › Piloting/Steering › Swing Meter
Issued 22 August 2006
Resolved
During steering gear test, observed ruddle angle indicator is not operating correctly. It is is stuck at 10 degrees STBD and will not show accurate rudder angle.
Engineering › Diesel Engine (propulsion-direct drive) › Cylinder
Issued 22 August 2006
Resolved
Provide flag survey report attesting to the condition and status of main propulsion engine.
Documentation › Certificates/Documents › Safety Management Certificate (ISM)
Issued 16 February 2006
Resolved
Certificate Expired
Engineering › Diesel Engine (propulsion-direct drive) › Block
Issued 16 February 2006
Resolved
Main Engine Inoperable
Operations/Management › Port and Waterways Safety › Notice of Arrival, General
Issued 6 December 2005
Resolved
06 DEC 05: M/V GRACE failed to submit an ANOA to the NVMC. Vessel arrived at the port of Miami anchorage. It has been confimed through the NVMC that the vessel failed to submit a proper ANOA. Vessel is ordered to depart U.S. Waters immediately.
Personnel › Certificates/Documents/Licenses › Medical Fitness Document
Issued 28 July 2005
Resolved
Provide Medical Certification for AB and Cook.
Construction/Loadline › Structures › Machinery Space Opening
Issued 28 July 2005
Resolved
Properly seal open penatrations in FWD bulkhead in steering room.
Fire Fighting › Means of Escape › Blocked
Issued 28 July 2005
Resolved
Provide key box at escape forward of generators on bow.
Documentation › Certificates/Documents › Document of Compliance (ISM)
Issued 28 July 2005
Resolved
Provide ISM Certificate
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 28 July 2005
Resolved
Fire detection system inoprative. Provide class report to attest to the operation of fixed system.
Engineering › Generator (propulsion-electric) › Measurement Circuitry
Issued 19 November 2003
Resolved
Demonstrate proper operation of main generator.
Engineering › Diesel Engine (propulsion-reduction gear) › Cylinder
Issued 19 November 2003
Resolved
Repair #3 cylinder on main engine.
Deck/Cargo › Ballast › Piping
Issued 19 November 2003
Resolved
Repair ballast and bilge piping and pumps.
Documentation › Certificates/Documents › Cargo Ship Safety Construction Certificate
Issued 19 November 2003
Resolved
Complete a machinery, loadline, and firefighting survey.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 19 November 2003
Resolved
Repair or replace the numerous deficiencies listed in the special notes section.
Fire Fighting › Fire Main
Issued 19 November 2002
Resolved
Fire main wasted and/or holed in various location on the vessel IAW CCSSC Chapter 3/ Regualtion 3.4. Repair or replace prior to loading and departure from port. LEGACY COMPONENT DESC: Condition
Personnel › Certificates/Documents/Licenses
Issued 19 November 2002
Resolved
Provide proof from Cambodia that terminology used on certificates of the Bosun, Oiler, and Able Seaman are accepted by the Cambodian administration IAW STCW 95.
Personnel › Manning/Qualifications
Issued 19 November 2002
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Personnel › Certificates/Documents/Licenses
Issued 19 November 2002
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Accommodation/Occupational Safety › Ventilation
Issued 19 November 2002
Resolved
Provide adequate power ventilation for engine room.
Pollution Prevention/Response › Response Equipment
Issued 17 October 2002
Resolved
Repair leak in hydraulic line located forward main deck, stbd side just before ladderwell. LEGACY COMPONENT DESC: Non-sparking Portable Pump/Hoses
Deck/Cargo › Holds/Tanks
Issued 17 October 2002
Resolved
Have Class / Flag attest to the replacement of tank covers located on cargo hold #3 (threads are missing and corroded making it impossible to secure the tank).
Electrical › Electrical Distribution System (service)
Issued 17 October 2002
Resolved
Repair loose wireing stbd side above main diesel engine. LEGACY COMPONENT DESC: Wiring
Accommodation/Occupational Safety › Occupational Safety
Issued 17 October 2002
Resolved
Replace or repair corroded / weak deck plate aft engine room port side.
Personnel › Manning/Qualifications
Issued 17 October 2002
Resolved
Provide proper manning of vessel in accordance with safe manning certificate and STCW 78/95. Vessel is presently without a Chief Mate, Chief Engineer and Bosun. Chief Mate and Chief Engineer had false licences. Vessel did not have a bosun. LEGACY COMPONENT DESC: Minimum Safe Manning
Personnel › Certificates/Documents/Licenses
Issued 17 October 2002
Resolved
Provide medical certificates for entire crew. Only four crew members had medical certificates available. LEGACY COMPONENT DESC: Medical Fitness Document
Accommodation/Occupational Safety › Occupational Safety
Issued 17 October 2002
Resolved
Provide non-conductive matting for switch board in engine room.
Personnel › Manning/Qualifications
Issued 11 February 2002
Resolved
Provide a valid Safe Manning Certificate on board. The present certificate expired on 05FEB02. LEGACY COMPONENT DESC: Minimum Safe Manning
Navigation › Piloting/Steering
Issued 11 February 2002
Resolved
Provide new and updated charts onboard. LEGACY COMPONENT DESC: Marine Charts
Navigation › Piloting/Steering
Issued 11 February 2002
Resolved
Provide Tide Tables and Tidal Current tables onboard. LEGACY COMPONENT DESC: Tide/Tidal Current Tables
Navigation › Piloting/Steering
Issued 11 February 2002
Resolved
Provide update deviation table prior to next US Port. LEGACY COMPONENT DESC: Deviation Table/Graph
Lifesaving › Line-Throwing Appliances
Issued 11 February 2002
Resolved
Provide two (2) line-throwing devices.
Lifesaving › Launching Appliances
Issued 11 February 2002
Resolved
Provide and post instruction for launching and recovery of rescue boat.
Lifesaving › Inflatable Liferafts
Issued 11 February 2002
Resolved
Have both the port and starboard life rafts serviced. Last servicing was January 2001.
Lifesaving › Lifebuoys
Issued 11 February 2002
Resolved
Replace the attachment line for the light to the aft port ring buoy. LEGACY COMPONENT DESC: Buoyant Lifeline
Construction/Loadline › Penetrations
Issued 11 February 2002
Resolved
There is a wooden plug in the ballast overboard valve located in the forward port side engine room. Make permanent and proper repairs. LEGACY COMPONENT DESC: Valve Flange
Construction/Loadline › Penetrations
Issued 11 February 2002
Resolved
There is a soft patch around the ballast overboard valve located in the forward starboard side of the engine room. Make permanent and proper repairs. LEGACY COMPONENT DESC: Valve Flange
Accommodation/Occupational Safety › Occupational Safety
Issued 11 February 2002
Resolved
Install guards over the moving parts for the port side generator / prime mover. LEGACY COMPONENT DESC: Guards for Exposed Hazards
Construction/Loadline › Structures
Issued 11 February 2002
Resolved
The top of the bilge tank located in the forward centerline of engine room bilge has a 3" hole. Make permanent and proper repairs.
Construction/Loadline › Structures
Issued 11 February 2002
Resolved
The overhead above both the generators in the engine room is holed. Deck above is cemented over and appears to be rusted through. Make permanent and proper repairs. LEGACY COMPONENT DESC: Deck Plating
Fire Fighting › Fire Main
Issued 11 February 2002
Resolved
The fire main the bilge of engine room has a pinhole and a soft patch in a 4-foot section. Section is located in the port bilge near aft end of main engine. LEGACY COMPONENT DESC: Condition
Lifesaving › Inflatable Liferafts
Issued 11 February 2002
Resolved
Provide and post the operating instruction for both port and starboard life rafts.
Fire Fighting › Fire Hoses
Issued 11 February 2002
Resolved
Replace the fire hose that busted during the test of the fire main. Hose is located in the port accommodation passageway next to engine room. LEGACY COMPONENT DESC: Condition
Pollution Prevention/Response › Prevention Equipment
Issued 11 February 2002
Resolved
Provide a standard oil discharge connection. LEGACY COMPONENT DESC: Standard Discharge Connection
Fire Fighting › Fixed Fire Detection System
Issued 11 February 2002
Resolved
Have Class address the fact there is no fire detection in the engine room as required by CCSSC 3.16.7. Vessel is partially unmanned.
Construction/Loadline › Structures
Issued 11 February 2002
Resolved
Make permanent and proper repairs to the overhead of the radio space of the bridge. There is a patch to the deck of the frying bridge that is leaking. LEGACY COMPONENT DESC: Superstructure
Engineering › Freshwater System (jacketwater cooling)
Issued 11 February 2002
Resolved
The hose connected to the fresh water-cooling pump, for the port side generator / prime mover has a soft patch and is leaking. Make permanent and proper repairs. LEGACY COMPONENT DESC: Hose
Construction/Loadline › Structures
Issued 11 February 2002
Resolved
Make permanent and proper repairs to the aft centerline hatch leading to the cargo hold. Hatch is not watertight and hinge is broken. LEGACY COMPONENT DESC: Scuttle
Electrical › Lighting (service)
Issued 11 February 2002
Resolved
Replace the broken light switch cover to the switch at top of ladder leading out of accommodation space, port side. LEGACY COMPONENT DESC: Switch
Lifesaving
Issued 11 February 2002
Resolved
EPIRB on upper starboard bridge deck is not float free; EPIRB is cemented in place when deck was cover with cement. Make EPIRB float free. LEGACY COMPONENT DESC: EPIRB
Lifesaving › Rescue Boat
Issued 11 February 2002
Resolved
Battery for rescue boat winch is missing. Provide a battery and demonstrate proper launching and recovering of rescue boat. LEGACY COMPONENT DESC: Embarkation/Disembarkation Capabilities
Pollution Prevention/Response › Prevention Equipment
Issued 11 February 2002
Resolved
Remove all gear and debris from all the containments around the fuel tank vents. Crew is using containments for storage. LEGACY COMPONENT DESC: Fixed Containment
Electrical › Electrical Distribution System (service)
Issued 11 February 2002
Resolved
Exterior electrical outlet is just hanging off of bulkhead of forecastle, centerline forward of cargo hold. Make proper connections. LEGACY COMPONENT DESC: Outlet Box
Electrical › Electric Generation Source (emergency)
Issued 11 February 2002
Resolved
Starting assembly box, for forward generator is just hanging and connections are bare. Make proper connections. LEGACY COMPONENT DESC: Metallic Enclosure/Frame
Navigation › Collision/Grounding Avoidance
Issued 11 February 2002
Resolved
Both the port and starboard navigation lights are using household light bulbs and arc of illumination is improper. Install the navigation lights in accordance with the International Navigation Rules. LEGACY COMPONENT DESC: Navigation Lights
Documentation › Certificates/Documents
Issued 11 February 2002
Resolved
Provide the original Caribbean Code of Safety Certificate and equipment list onboard for review. LEGACY COMPONENT DESC: Cargo Ship Safety Certificate
Personnel › Manning/Qualifications
Issued 11 February 2002
Resolved
Man vessel in accordance with the Minimum Safe Manning Certificate and demonstrate a satisfactory fire drill, abandon ship drill and man overboard drill to the attending US Coast Guard Inspector. LEGACY COMPONENT DESC: Minimum Safe Manning
Lifesaving › Buoyant Smoke Signals
Issued 11 February 2002
Resolved
Provide evidence of the servicing for the bridge smoke buoys. Markings are weathered.
Electrical › Electric Generation Source (service)
Issued 11 February 2002
Resolved
Relocate the starting battery for the forward generator from under the fuel filter. LEGACY COMPONENT DESC: Starting Battery
Electrical › Electric Generation Source (service)
Issued 11 February 2002
Resolved
Install the flame bowl for under the Racor filter for forward generator as required by the manufacture of the filter. LEGACY COMPONENT DESC: Fuel Filter
Construction/Loadline › Structures
Issued 11 February 2002
Resolved
Deck above the forward peak is holed around the access cover. Make permanent and proper repairs. LEGACY COMPONENT DESC: Deck Plating
Construction/Loadline › Structures
Issued 11 February 2002
Resolved
Deck in forecastle area is holed around the port side deep frame. Oil is leaking for stored motors and is leaking into forward peak. LEGACY COMPONENT DESC: Deck Plating
Fire Fighting › Fire Hydrants
Issued 11 February 2002
Resolved
Fire hydrant on the upper port aft bridge deck is not able to be opens. Demonstrate proper predation of the valve. LEGACY COMPONENT DESC: Condition
Accommodation/Occupational Safety › Cooking Systems
Issued 11 February 2002
Resolved
Replace the regulating valve and copper tube assembly for the propane line at the stove, in galley. Copper tube is bent a holed and regulating valve has liquid steel poured over it. LEGACY COMPONENT DESC: LPG System Requirements
Fire Fighting › Firemans Outfit
Issued 11 February 2002
Resolved
Unknown Component - Improper/Lack of Maintenance
Documentation › Certificates/Documents
Issued 23 January 2002
Resolved
Provide proof of a valid Caribbean Cargo Ship Safety Certificate (CCSSC) prior to departure. LEGACY COMPONENT DESC: Cargo Ship Safety Certificate
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.