← All vessels
N.M.S. FUELER NO. 1
Tank Barge · Barge class · Built 1970s · USCG Heartland District (CGD-H) · Other hulls named N.M.S. FUELER NO. 1
N.M.S. FUELER NO. 1 is a 1970 tank barge. The Coast Guard has recorded 44 inspections since 1981, most recently in October 2014, along with 47 deficiencies.
Records from 1981 to 2014. Most recent: inspection, 6 October 2014.
- Built
- 1970
- Last inspected
- 6 October 2014
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 47 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
529763
46760
Flag
UNITED STATES
—
Maury page id
psix-46760
Inspections, by type
…with no type recorded2
Years with a record
29 calendar years (1981–2014)
The 44 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 12 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.
Documentation record
Registered dimensions (L × B × D)115.0 ft × 30.0 ft × 7.0 ft
Registered tonnagegross 203 / net 203
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMISSOURI VALLEY STEEL INC · LEAVENWORTH, KS, UNITED STATES · built 1970
Hull materialSteel
PropulsionNot recorded
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portST LOUIS, MO
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 22 August 2026 · expires 30 September 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it203 - Regulatory (Subpart C or D), Gross Ton
203 - Regulatory (Subpart C or D), Net Ton
203 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 44
6 October 2014
Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5002021
19 August 2013
Administrative Inspection · COI Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4689765
30 April 2012
COI Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4295940
25 July 2011
Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4087025
29 October 2010
Administrative Inspection · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3880583
8 July 2009
Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3528241
23 April 2009
Drydock Exam · Internal Structural Exam
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3458516
14 November 2008
Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3363063
1 July 2008
Administrative Inspection · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3253320
9 May 2007
COI Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 2924101
28 June 2006
Annual Inspection · Deficiency Check · MTSA Verification · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 2694676
24 June 2005
Deficiency Check · Annual Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2369731
24 March 2004
Annual Inspection · Hull Examination · Cargo Tank Internal · Internal Structural Exam
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2030540
26 June 2003
Annual Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1814766
5 June 2002
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1626789
9 May 2002
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1614681
1 June 2001
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1382263
4 May 2000
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1413720
3 June 1999
Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 803211
2 April 1999
Re-Inspection · Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1406474
4 May 1998
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1473374
11 July 1997
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1433228
15 May 1997
Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1103557
24 May 1996
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1084342
10 May 1996
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1427209
30 May 1995
Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 871898
26 April 1995
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1172083
18 May 1994
Hull Examination · COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1422309
9 October 1992
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1259504
2 December 1991
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 940762
12 November 1991
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 942666
11 December 1990
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 922117
7 November 1990
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1224098
29 November 1989
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 928386
15 November 1989
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 900205
2 November 1989
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1000627
14 November 1988
Hull Examination · COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1194377
18 August 1988
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1346590
11 February 1988
MARPOL Annex II Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1019705
2 December 1986
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1332674
12 February 1986
Examination of Repairs
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1293010
9 January 1986
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1298333
27 November 1984
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1286444
18 May 1981
Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1273893
Deficiency record · 47
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 31 October 2008
Resolved
Temporary piping installed through 2 cargo hatches is not in compliance.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 29 June 2006
Resolved
Hoses, boom, wooden plank, unused equipment improperly stowed on barge deck.
Deck/Cargo › Cargo Stowage › General
Issued 29 June 2006
Resolved
Improper use of plastic valve on starboard deck tank.
Deck/Cargo › Cargo Stowage › General
Issued 29 June 2006
Resolved
Ullage bolts on port deck tank loose/missing.
Deck/Cargo › Cargo Stowage › General
Issued 29 June 2006
Resolved
Cargo hatch gaskets worn.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 24 June 2005
Resolved
Properly install all bolts on manhole covers for both on deck cargo tanks.
Electrical › Lighting (service) › Lighting Fixture
Issued 24 June 2005
Resolved
Properly replace light bulb in forward deck light.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 24 June 2005
Resolved
Maintain onboard the vessel a copy of the vessel response plan.
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 24 June 2005
Resolved
Include in the transfer procedures a product list and detailed description of transfer system operation.
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 24 June 2005
Resolved
Properly maintain red light onboard for use during night transfer operations as per transfer procedures.
Construction/Loadline › Markings › Load Line Mark
Issued 24 March 2004
Resolved
Load lines are not in contrasting color.
Deck/Cargo
Issued 24 March 2004
Resolved
Conduit lines were not properly secured.
Operations/Management › Cargo Transfer/Lightering
Issued 24 March 2004
Resolved
Vsl transfer diagram is inacurrate.
Deck/Cargo › Cargo Stowage › Fixed Containment
Issued 24 March 2004
Resolved
Deck slop/cargo tanks not properly marked.
Electrical › Electrical Distribution System (service)
Issued 9 May 2002
Resolved
Prior to energizing shore tie, remove all water, determine source of leak and properly repair electrical locker to prevent reoccurrence. LEGACY COMPONENT DESC: Shore Connection Box
Construction/Loadline › Markings
Issued 9 May 2002
Resolved
Re-paint vessel draft marks. LEGACY COMPONENT DESC: Draft Marks/Indicating System
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 9 May 2002
Resolved
Renew all oil service hoses. Hydrostatically test and label all hoses for oil service only. LEGACY COMPONENT DESC: Transfer Hose
Deck/Cargo
Issued 4 May 1998
Resolved
Replace flame screen on stbd deck slop oil tank gooseneck.
Deck/Cargo
Issued 10 May 1996
Resolved
REPLACE PLUGS OR PROVIDE FLAME SCREENS AND COVERS FOR FOUR CONTAINMENT DRAINS INSIDE COAMING. DRAINS DIRECTLY INTO EACH CARGO TANK.
Electrical
Issued 10 May 1996
Resolved
PROVIDE RUBBER MATTING UNDER ELECTRICAL PANEL BOX IWO ELECTRICAL SPACE.
Electrical
Issued 10 May 1996
Resolved
REPLACE MISSING BLANK ON ELECTRICAL PANEL BOX.
Deck/Cargo
Issued 12 November 1991
Resolved
TIGHTEN PACKING/REPACK REACH-RODS 1P & 1S CARGO TANKS.
Electrical
Issued 12 November 1991
Resolved
REPAIR STICKING ON/OFF SWITCH TO VACUUM PUMP, INSTALL WEATHER TIGHT COVER FOR SAME.
Lifesaving
Issued 12 November 1991
Resolved
REAPPLY NEW WARNING SIGN TO STBD AFT DECK CARGO TANK, REPAINT DRAFT MARKS ON HULL.
Lifesaving
Issued 12 November 1991
Resolved
STENCIL "DANGER KEEP OUT" ON ALL CARGO HATCHES.
Construction/Loadline
Issued 12 November 1991
Resolved
DEWATER BOW RAKE.
Electrical
Issued 12 November 1991
Resolved
TIGHTEN ALL BOLTS ON VACUUM PUMP MOTOR CONTROLLER.
Unknown
Issued 12 November 1991
Resolved
REMOVE "OLD" DIESEL FUEL TANK AND ASSOCIATED PIPING.
Construction/Loadline
Issued 7 November 1990
Resolved
MAKE PERMANENT REPAIRS TO DECK FRACTURE AT PORT STERN CORNER.
Construction/Loadline
Issued 7 November 1990
Resolved
RESTENCIL DRAFT MARKS.
Deck/Cargo
Issued 7 November 1990
Resolved
REPAIR OR REPLACE LEAKING CHECK VALVE TO DISCHARGE LINE OFF OF VACUUM TANK.
Construction/Loadline
Issued 7 November 1990
Resolved
RESTENCIL WARNING SIGNS ON CARGO TANK HATCHES.
Construction/Loadline
Issued 7 November 1990
Resolved
REMOVE OILY DEBRIS ON DECK.
Deck/Cargo
Issued 7 November 1990
Resolved
STENCIL SERVICE AND MAXIMUM ALLOWABLE WORKING PRESSURE ON ALL TRANSFER HOSES.
Deck/Cargo
Issued 2 November 1989
Resolved
RESTENCIL CARGO TANK WARNING NOTICE.
Electrical
Issued 2 November 1989
Resolved
PRIOR TO NEXT TRANSFER REINSTALL FRONT COVER ON MAIN DISTRIBUTION PANEL.
Electrical
Issued 2 November 1989
Resolved
REMOVE WIRE NUT AND MAKE PROPER MECHANICAL WIRE SPLICE IN MAIN DISTRIBUTIONPANEL.
Deck/Cargo
Issued 2 November 1989
Resolved
PRIOR TO NEXT TRANSFER MAKE ALL CARGO TANK REACH RODS VAPOR TIGHT.
Fire Fighting
Issued 2 November 1989
Resolved
PRIOR TO NEXT TRANSFER SERVICE B-II PORTABLE FIRE EXTINGUISHER.
Fire Fighting
Issued 2 November 1989
Resolved
PROVIDE APPROVED MOUNTING BRACKET FOR B-II PORTABLE FIRE EXTINGUISHER.
Electrical
Issued 2 November 1989
Resolved
PRIOR TO NEXT TRANSFER INSTALL AND/OR TIGHTEN COVER BOLTS ON EXPLOSION PROOF ELECTRICAL BOXES.
Electrical
Issued 18 August 1988
Resolved
INSTALL BLANK IN THE MAIN DISTRIBUTION PANEL.
Construction/Loadline
Issued 18 August 1988
Resolved
RENEW DRAFT MARKINGS
Construction/Loadline
Issued 18 August 1988
Resolved
DISCHARGE CARGO AND PRIOR TO RELOADING NEXT CARGO MAKE PERMANENT REPAIRS TOTHE HOLE IN THE MAIN DECK OVER THE FORWARD RAKE NEAR THE CENTERLINE OF THE VESSEL AND GAUGE WASTED AREA ACROSS RAKE AFT ACROSS CARGO TANK #1, ALSO MAKE PERMANENT REPAIRS TO FRACTURE AT PORT AFT CORNER OF AFT VOID.
Documentation
Issued 18 August 1988
Resolved
RENEW WARNING KEEP OUT SIGNS AT EACH CARGO TANK TRUNK.
Deck/Cargo
Issued 18 August 1988
Resolved
STENCIL "EMERGENCY SHUTDOWN" ON CARGO PUMP MOTOR CONTROLLER BOX NEAR CARGO PUMP MOTOR.
Documentation
Issued 18 August 1988
Resolved
RENEW OIL TRANSFER PROCEEDURES AND PROVIDE COPY TO [name withheld] FOR REVIEW AND APPROVAL.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.