MAURY USCG vessel records Sign in
← All vessels

BAYAMON

BAYAMON is a 1970 freight ship. The Coast Guard has recorded 35 inspections since 1985, most recently in October 2008, along with 18 deficiencies.

Records from 1985 to 2008. Most recent: inspection, 6 October 2008.

Built
1970
Last inspected
6 October 2008
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7037284 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
UNITED STATES
—
Maury page id
psix-46776

Inspections, by type

…with no type recorded18
Years with a record 6 calendar years (1985–2008)
The 35 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it14407 - Dead Weight, Ton
15131 - Regulatory (Subpart C or D), Gross Ton
10004 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WIAGMMSI not assigned · expired · compulsorily equipped · granted 19 March 1987, cancelled 19 March 1992
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 35

6 October 2008 Type not recorded
No type recorded · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 3339446
10 September 2008 Type not recorded
No type recorded · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 3331547
15 February 2008 Load Line/Change of Employment
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 3147958
23 June 1989 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1201854
12 May 1989 Administrative
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1344089
15 August 1988 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 453671
5 July 1988 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1031411
5 July 1988 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1210453
17 June 1988 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 891634
3 February 1988 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1325745
29 January 1988 Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1017997
19 January 1988 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1323519
8 January 1988 MARPOL Annex II Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1009536
3 January 1988 Deficiency Check · Examination of Repairs
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1008005
7 December 1987 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 504284
30 October 1987 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 500869
11 September 1987 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1321127
30 July 1987 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1333347
24 July 1987 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1023374
8 June 1987 COI Inspection · Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1313596
20 April 1987 Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1321147
14 April 1987 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1023070
6 April 1987 Plan Review "T" Boat
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1329506
8 August 1986 Examination of Repairs
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 999074
24 July 1986 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 991593
2 July 1986 Examination of Repairs
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1305067
25 June 1986 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 995241
24 June 1986 Examination of Repairs · Credit Drydock · COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1303223
22 July 1985 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 982502
10 May 1985 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 502347
12 April 1985 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 979642
29 March 1985 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 979644
22 March 1985 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1287162
5 March 1985 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 498520
4 February 1985 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 980771

Deficiency record · 18

Engineering
Issued 17 June 1988 Resolved
HYDRO TEST UNFIRED PRESSURE VESSELS.
Condition: Unknown
Due 17 June 1988
Resolved 17 June 1988
Engineering
Issued 17 June 1988 Resolved
REPAIR WASTED LOW PRESSURE STEAM DRAIN UNDER FIRE PUMP.
Condition: Unknown
Due 17 June 1988
Resolved 17 June 1988
Construction/Loadline
Issued 3 January 1988 Resolved
MAKE PERMANENT REPAIRS TO FRACTURES AT VESSEL'S LAY-UP TO COMMENCE 29DEC87 BUT IN NO CASE LATER THAN 02JAN88.
Condition: Unknown
Due 3 January 1988
Resolved 3 January 1988
Construction/Loadline
Issued 3 January 1988 Resolved
MAKE TEMPORARY REPAIRS TO THE TWO VERTICAL FRACTURES LOCATED ON THE PORT BOW IN WAY OF FRAMES 7/8 AND 13/14.
Condition: Unknown
Due 3 January 1988
Resolved 3 January 1988
Construction/Loadline
Issued 11 September 1987 Resolved
REEXAMINE AND REPAIR AS NECESSARY THE INSET AT THE TRANSOM 20FT OFF THE CENTERLINE ABOVE THE STEERING GEAR DECK/ AFTER PEAK TANK TOP.
Condition: Unknown
Due 8 June 1989
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Engineering
Issued 30 July 1987 Resolved
E1-REPAIR AND PROVE PROPER OPERATION OF THE ELECTRICAL 440V STANDBY FUEL OIL INPORT HEATER....RECEIVED STATEMENTS FROM THE ENGINEER ON WATCH, MASTERAND CG 2692.
Condition: Unknown
Due 30 July 1987
Resolved 30 July 1987
Fire Fighting
Issued 25 June 1986 Resolved
TEST KIDDE SMOKE DETECTOR SYSTEM FOR CARGO HOLDS.
Condition: Unknown
Due 25 June 1986
Resolved 25 June 1986
Electrical
Issued 25 June 1986 Resolved
TEST VENT SHUTDOWN (REMOTE STOPS) FOR CARGO HOLDS.
Condition: Unknown
Due 25 June 1986
Resolved 25 June 1986
Unknown
Issued 25 June 1986 Resolved
TEST CARBON MONOXIDE INDICATING SYSTEM FOR CARGO HOLDS.
Condition: Unknown
Due 25 June 1986
Resolved 25 June 1986
Electrical
Issued 25 June 1986 Resolved
TEST VENT SHUTDOWN FOR EMERGENCY ROOM, CO2 PRESSURE OPERATED SWITCH TO BREAKERS 5P39 AND 8P39.
Condition: Unknown
Due 25 June 1986
Resolved 25 June 1986
Fire Fighting
Issued 24 June 1986 Resolved
REPAIR LEAK IN SPRINKLER PIPE TO ZONE NO.4. TO BE COMPLETED PRIOR TO LEAVING THE PORT OF JACKSONVILLE.
Condition: Unknown
Due 24 June 1986
Resolved 24 June 1986
Electrical
Issued 24 June 1986 Resolved
DEAD END ELECTRICAL CABLES AT FIRE EXTINGUISHER STATION 35, NO.5 CARGO HOLDREMOVE CABLES OR PLACE IN JUNCTION BOXES.
Condition: Unknown
Due 24 June 1986
Resolved 24 June 1986
Unknown
Issued 24 June 1986 Resolved
CONDUCT TEST OF EMERGENCY GENERATOR AND EMERG. POWER, TEST SUPERHEATER SAFETY VALVE, TEST GENERAL ALARM, TEST REMOTE STOP FOR CARGO HOLD FANS. TO BE COMPLETED PRIOR TO LEAVING PORT OF JACKSONVILLE.
Condition: Unknown
Due 24 June 1986
Resolved 24 June 1986
Electrical
Issued 24 June 1986 Resolved
SOUND POWER PHONE REQUIRED FOR BOW LOOKOUT (46CFR113.30-5(G). THE LOOKOUT SHALL BE PROVIDED WITH A HAND HELD PORTABLE RADIO FOR COMMUNICATION WITH THE BRIDGE WATCH UNTIL SUCH TIME AS THIS REQUIREMENT IS SATISFIED.
Condition: Unknown
Due 24 June 1986
Resolved 24 June 1986
Engineering
Issued 24 June 1986 Resolved
RENEW THE RUBBER EXPANSION JOINTS TO MAIN CONDENSER PIPING. ONE-42", ONE-36", ONE-24", ONE-10". THE JOINTS HAVE SMALL CRACKS ON EXTERIOR.
Condition: Unknown
Due 24 June 1986
Resolved 24 June 1986
Construction/Loadline
Issued 24 June 1986 Resolved
THE RAMS IN THE HYDRAULIC CYLINDERS FOR DOGGING MECHANISM AT WATERTITE DOORNO.3 ARE BENT AND LEAKING. REPAIR THE TWO CYLINDERS.
Condition: Unknown
Due 24 June 1986
Resolved 24 June 1986
Engineering
Issued 22 March 1985 Resolved
REPAIR STEAM OPERATING VALVE ON EMERGENCY LUBE OIL PUMP.
Condition: Unknown
Due 22 March 1985
Resolved 22 March 1985
Engineering
Issued 22 March 1985 Resolved
REPAIR HIGH ATOMIZING STEAM ALARM.
Condition: Unknown
Due 22 March 1985
Resolved 22 March 1985

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.