OCEAN BIRD is a 1991 freight ship. The Coast Guard has recorded 25 inspections since 1998, most recently in August 2011, along with 11 deficiencies and 5 operational controls.

Records from 1998 to 2011. Most recent: operational control imposed, 16 August 2011.

Built
1991
Last inspected
16 August 2011
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8919817 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
467809
Flag
DENMARK
—
Maury page id
psix-467809

Inspections, by type

…with no type recorded15
Years with a record 11 calendar years (1998–2011)
The 25 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 15 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it1724 - Convention (Subpart B), Net Ton
4756 - Dead Weight, Ton
6702 - Displacement, Ton
3320 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 25

16 August 2011 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 4138261
30 March 2010 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3694629
18 March 2010 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3697900
5 January 2010 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3658224
5 January 2010 Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3660784
28 February 2008 Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3155226
25 February 2008 Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3153043
18 April 2007 ISPS II Exam · PII Safety Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2908822
18 April 2007 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2911538
17 April 2007 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2908701
6 March 2006 Random ISPS/MTSA/PSC
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2596746
6 March 2006 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2597693
18 March 2005 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2313824
11 August 2002 Ballast Water Examination · Passenger/Freight Vessel Examination
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 1659441
1 August 2002 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1658923
25 March 2002 Control Verification
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1597100
15 March 2002 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1492541
27 September 2001 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 294126
27 September 2001 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 294237
6 March 2000 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 275461
15 February 1999 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 425480
25 September 1998 Type not recorded
No type recorded · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 420747
15 March 1998 Type not recorded
No type recorded · MSFO Portsmouth · USCG Northeast District (CGD-NE) · Activity 413610
27 January 1998 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 412144
27 January 1998 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 412410

Deficiency record · 11

Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 30 March 2010 Resolved
Class "A" Fire Doors being mechanically held open in emergency escape trunk, engine room, and steering gear room. Self closing Class "A" & "B" Fire Doors in engine room and throughout the house are not self closing. 74 SOLAS (1992) II-2 / 30.4
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 March 2010
Resolution: Crew removed "hold-backs" and adjusted hinges on all fire doors. Deficiency cleared.
Fire Fighting › Combustible Materials › Insulation
Issued 30 March 2010 Resolved
Excessive oil and oil soaked lagging around engine booster pump, purifiers and main engine. 74 SOLAS (1992) II-2 / 26.7
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 March 2010
Resolution: PSCO''s from Sector Charleston observed engine room after engineers cleaned oil and replaced lagging. Deficiency cleared.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 30 March 2010 Resolved
Maintenance equipment stored inside main switchboard. 74 SOLAS (1992) II-1 / 45.2
Due 30 March 2010
Resolved 30 March 2010
Resolution: Deficiency rectified on the spot.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 30 March 2010 Resolved
Miscellaneous equipment stored inside safety railing in steering gear room. SOLAS (1992) II-2 / 29.13.3
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 March 2010
Resolution: PSCO''''''''s from U.S.C.G. Sector Charleston observed steering gear after equipment had been removed. Deficiency cleared.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 18 April 2007 Resolved
Found life jackets located in the engine control room having deteriorated retro-reflective materials. Fix retro-reflective tape on life jackets.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 May 2007
Resolved 28 February 2008
Resolution: Vessel provided notice of lifejackets being refitted with retroflective tape.
Navigation › Emergency Steering › Communications to Emergency Steering
Issued 6 March 2006 Resolved
Prove proper operation of means of commuication between birdge and steering gear compartment. To the satisfaction of class
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 8 March 2006
Resolved 8 March 2006
Resolution: Received class report confirming repairs.
Electrical › Electric Generation Source (emergency) › Circuit Breaker
Issued 6 March 2006 Resolved
Investigate source of power loss and failure of circuit breaker for emergency generator. To the satisfaction of class.
Action required: 17 - Rectify deficiencies prior to departure
Due 8 March 2006
Resolved 8 March 2006
Resolution: Received tech and class report confirming repairs.
Fire Fighting
Issued 27 September 2001 Resolved
All firedoors in stairways are not self-closing and have hold back devices (4) not in accordance with the fire control plan. IAW Solas 74 (amm.) CH II-2 Regs 46.1 and 47.2 remove holdback devices and install self-closing devices to the satisfaction of Safety Construction Cert. Issuing Authority
Condition: Unknown
Due 28 October 2001
Resolved 15 March 2002
Resolution: RECEIVED CLASS REPORT VIA FAX. DOOR HOLD BACK HOOKS HAVE BEEN REMOVED , AND DOORS ARE RATED SELF-CLOSING FIRE DOOR TYPE B15.
Lifesaving
Issued 27 January 1998 Resolved
Rescue boat carried away in heavy weather - SOLAS 74 amended III/26.2_x001C_ _x001C_ Class or Flag approval required to sail without rescue boat until replacement could be obtained
Condition: Unknown
Due 27 January 1998
Resolved 2 February 1998
Electrical
Issued 27 January 1998 Resolved
Lights in paint locker not explosion proof, and in need of maintenance - SOLAS 74 amended II-1/45.10
Condition: Unknown
Due 16 March 1998
Resolved 16 March 1998
Fire Fighting
Issued 27 January 1998 Resolved
International Shore Connection stowed without gasket, nuts, bolts and washer - SOLAS 74 amended II-2/19.4
Condition: Unknown
Due 16 March 1998
Resolved 16 March 1998

Ownership record